KAWASAKI Boiler and Absorption Chiller for Co-generation system 14 November, 2018 Kawasaki Thermal Engineering Co., Ltd. Overseas Project Department

Transcript of KAWASAKI Boiler and Absorption Chiller for Co-generation ...Once Through Boiler “IF Series” A...

Page 1: KAWASAKI Boiler and Absorption Chiller for Co-generation ...Once Through Boiler “IF Series” A Comparison of KTE’s Line-up Boiler Water Tube Fire Tube Once-through (KF) Once-through

KAWASAKIBoiler and Absorption Chillerfor Co-generation system

14 November, 2018

Kawasaki Thermal Engineering Co., Ltd.

Overseas Project Department

Page 2: KAWASAKI Boiler and Absorption Chiller for Co-generation ...Once Through Boiler “IF Series” A Comparison of KTE’s Line-up Boiler Water Tube Fire Tube Once-through (KF) Once-through

2© 2015 Kawasaki Heavy Industries, Ltd. All Rights Reserved

Organization of Kawasaki

Ship & Offshore Structure

Rolling Stock

Aerospace System

Energy System & Plant Engineering

Motorcycle & Engine

Precision Machinery & Robot

Kawasaki Thermal Engineering

Page 3: KAWASAKI Boiler and Absorption Chiller for Co-generation ...Once Through Boiler “IF Series” A Comparison of KTE’s Line-up Boiler Water Tube Fire Tube Once-through (KF) Once-through

KAWASAKIBoiler

Page 4: KAWASAKI Boiler and Absorption Chiller for Co-generation ...Once Through Boiler “IF Series” A Comparison of KTE’s Line-up Boiler Water Tube Fire Tube Once-through (KF) Once-through

4© 2015 Kawasaki Heavy Industries, Ltd. All Rights Reserved

Gas Turbine Cogeneration System

Chilled

Water

Supply

Electricity

Steam

NG

Heat Recovery Rate:23%

Efficiency:31%

Exhaust Gas

HRSG

Gas Turbine Generator

Boiler SteamAbsorption Chiller

Steam

Page 5: KAWASAKI Boiler and Absorption Chiller for Co-generation ...Once Through Boiler “IF Series” A Comparison of KTE’s Line-up Boiler Water Tube Fire Tube Once-through (KF) Once-through

5© 2015 Kawasaki Heavy Industries, Ltd. All Rights Reserved

Boiler planning (For example)

GT Model GPB17D GPB80D

Boiler Model RGB-60GE RGB-200GE

GT outlet exhaust gas amount

m3N/h 22,637 76,132

GT outlet exhaust gas temp.

Deg C 525 525

Drum pressure MPaG 0.83 1.68

Feed water temp. Deg C 60 60

Boiler inlet exhaustgas amount

m3N/h 22,637 76,132

Boiler inlet exhaust gas temp.

Deg C 525 525

Economizer outlet exhaust gas temp.

Deg C 114 123

Steam output kg/h 5,150 16,900

Heat Recovery Steam Generator (Water Tube Type)

Page 6: KAWASAKI Boiler and Absorption Chiller for Co-generation ...Once Through Boiler “IF Series” A Comparison of KTE’s Line-up Boiler Water Tube Fire Tube Once-through (KF) Once-through

6© 2015 Kawasaki Heavy Industries, Ltd. All Rights Reserved

Gas Engine Cogeneration System

Chilled

Water

Supply

Electricity

Hot Water

Supply

Steam

Hot Water Absorption Chiller

NG

CommercialPower

電力

Chilled WaterHot Water

Steam

Sub Station

HeatExchanger

Centrifugal Chiller

Heat Exchanger

Steam Absorption Chiller

Header

Steam

Exhaust Gas

HRSG

Gas Boiler

Exhaust Gas

Page 7: KAWASAKI Boiler and Absorption Chiller for Co-generation ...Once Through Boiler “IF Series” A Comparison of KTE’s Line-up Boiler Water Tube Fire Tube Once-through (KF) Once-through

7© 2015 Kawasaki Heavy Industries, Ltd. All Rights Reserved

• GE modelKAWASAKI KG-18-V

• Boiler modelRF-40GKE

• Boiler inlet exhaust gas35,800m3

N/h at 320℃

• Pressure0.80MPa

• Steam output3,190kg/h at 60℃

Boiler planning (For example)

Heat Recovery Steam Generator (Once Through)

Page 8: KAWASAKI Boiler and Absorption Chiller for Co-generation ...Once Through Boiler “IF Series” A Comparison of KTE’s Line-up Boiler Water Tube Fire Tube Once-through (KF) Once-through

8© 2015 Kawasaki Heavy Industries, Ltd. All Rights Reserved

Gas Turbine Cogeneration System

Chilled

Water

Supply

Electricity

Steam

NG

Heat Recovery Rate:23%

Efficiency:31%

Exhaust Gas

HRSG

Gas Turbine Generator

Boiler SteamAbsorption Chiller

Steam

Page 9: KAWASAKI Boiler and Absorption Chiller for Co-generation ...Once Through Boiler “IF Series” A Comparison of KTE’s Line-up Boiler Water Tube Fire Tube Once-through (KF) Once-through

9© 2015 Kawasaki Heavy Industries, Ltd. All Rights Reserved

Once Through Boiler “IF Series”

A Comparison of KTE’s Line-up Boiler

Water Tube Fire TubeOnce-through

(KF)Once-through

(IF)

Actual Evaporation

t/h 5 5 1.68×3 5

Weight ton 12 11.5 2.4×3=7.2 7.8

Retained Water Volume

L/t 3,000 6,000275×3=825 990

Cold startAdvantage

Min 40 40~60 10 15

Control

Combustion ContinuousIntermittent(3 positions)

Continuous

Water Feeding ContinuousIntermittent(2 positions)

Continuous

Heating Surface Area 1,174 693 106×3=318 317

Max. Boiler Efficiency (%) 94 92 98 98

Dimension (m2) 25 12.6 2.5×3=7.5 7.3

Note) The boiler efficiency is indicated on the steam pressure of 0.49Mpa, the feed water temperatureof 15 deg C and the room temperature of 35 deg C. The boiler efficiency shall have +/-3% allowance in concideration of the mesurement tolerance.

Page 10: KAWASAKI Boiler and Absorption Chiller for Co-generation ...Once Through Boiler “IF Series” A Comparison of KTE’s Line-up Boiler Water Tube Fire Tube Once-through (KF) Once-through

10© 2015 Kawasaki Heavy Industries, Ltd. All Rights Reserved

Summaries (1)

Why is Once-through Boiler popular in Japan?

HighEfficiency

CompactQuick

Start-up

Page 11: KAWASAKI Boiler and Absorption Chiller for Co-generation ...Once Through Boiler “IF Series” A Comparison of KTE’s Line-up Boiler Water Tube Fire Tube Once-through (KF) Once-through

11© 2015 Kawasaki Heavy Industries, Ltd. All Rights Reserved

Once Through Boiler “IF Series”

☆Harmonized Multi-Control for more than 2 Boilers

4.Efficiency 98% for Gas Fired,95% for Oil Fired (with Economizer)

1.Capacity 2.5 ~ 5 t/h

3.License

0.98 / 1.56 / 1.96/ 3.2 MPa

8.Option

7.Steam Dryness

PI Control(with de-aeration device)5.Control

Pressure Fluctuation: ±0.01 MPaRange of combustion:30~100%(Oil)

17~100%(Gas)

De-aeration device, PI combustion6.Life Cycle More than 15 years

Big Once-through Boiler

2.MaximumWorking Pressure

Not required in Japan

☆100% Drain Recovery at high pressure

More than 99.5%Equivalent Performance

& High dryness

Page 12: KAWASAKI Boiler and Absorption Chiller for Co-generation ...Once Through Boiler “IF Series” A Comparison of KTE’s Line-up Boiler Water Tube Fire Tube Once-through (KF) Once-through

12© 2015 Kawasaki Heavy Industries, Ltd. All Rights Reserved

Water Tube2.1%

Fire Tube3.0%

HRSG3.8%

Once Though (less than 2 ton)

35.5%

Once Though(over 2 ton)

55.7%

10,089ton(2016)

Boiler Market Trend in Japan

#Japan Boiler Association Market database

0

1,000

2,000

3,000

4,000

5,000

6,000

7,000

8,000

9,000

1994

1995

1996

1997

1998

1999

2000

2001

2002

2003

2004

2005

2006

2007

2008

2009

2010

2011

2012

2013

2014

2015

2016

Water Tube Smoke TubeHRSG Onece Though (below than 2 ton)Onece Though (over 2t)

Page 13: KAWASAKI Boiler and Absorption Chiller for Co-generation ...Once Through Boiler “IF Series” A Comparison of KTE’s Line-up Boiler Water Tube Fire Tube Once-through (KF) Once-through

Absorption Chiller

Page 14: KAWASAKI Boiler and Absorption Chiller for Co-generation ...Once Through Boiler “IF Series” A Comparison of KTE’s Line-up Boiler Water Tube Fire Tube Once-through (KF) Once-through

14© 2015 Kawasaki Heavy Industries, Ltd. All Rights Reserved

Gas Turbine Cogeneration System

Chilled

Water

Supply

Electricity

Steam

NG

Heat Recovery Rate:23%

Efficiency:31%

Exhaust Gas

HRSG

Gas Turbine Generator

Boiler SteamAbsorption Chiller

Steam

Page 15: KAWASAKI Boiler and Absorption Chiller for Co-generation ...Once Through Boiler “IF Series” A Comparison of KTE’s Line-up Boiler Water Tube Fire Tube Once-through (KF) Once-through

15© 2015 Kawasaki Heavy Industries, Ltd. All Rights Reserved

Absorption Chiller “Efficio”

Kawasaki had developed the highest efficient absorption chillerin the world in 2013

Note) COP is based on LHV

Page 16: KAWASAKI Boiler and Absorption Chiller for Co-generation ...Once Through Boiler “IF Series” A Comparison of KTE’s Line-up Boiler Water Tube Fire Tube Once-through (KF) Once-through

16© 2015 Kawasaki Heavy Industries, Ltd. All Rights Reserved

Steam Absorption Chiller “Efficio”

The Efficio delivers high annual operational efficiency by adopting a parallel-flow, solution invertercontrol and larger absorbent solution storage tank. These features ensure excellent efficiencyacross the full range of load conditions, contributing to greater energy savings.

The Efficio employs below items for highly efficient operation at partial load.

Parallel Flow

Solution Pump Inverter Control

Larger Absorbent Solution Storage Tank

Parallel flow can be operated with highefficiency at partial load.

Solution pump inverter control so that it canbe operated with high efficiency at partialload.

The larger absorbent solution storage tankprevents the heat transfer tubes in thesolution at low load. It can keep heat transferarea.

Partial Load Characteristics

Cooling water inlet temperature conditions are as specified by the JIS standards (32℃ at 100% load, 27℃ at 0% load, with the temperature varying proportionally at loads between 0% and 100%).

Page 17: KAWASAKI Boiler and Absorption Chiller for Co-generation ...Once Through Boiler “IF Series” A Comparison of KTE’s Line-up Boiler Water Tube Fire Tube Once-through (KF) Once-through

17© 2015 Kawasaki Heavy Industries, Ltd. All Rights Reserved

Gas Engine Cogeneration System

Chilled

Water

Supply

Electricity

Hot Water

Supply

Steam

Hot Water Absorption Chiller

NG

CommercialPower

電力

Chilled WaterHot Water

Steam

Sub Station

HeatExchanger

Centrifugal Chiller

Heat Exchanger

Steam Absorption Chiller

Header

Steam

Exhaust Gas

HRSG

Gas Boiler

Exhaust Gas

Page 18: KAWASAKI Boiler and Absorption Chiller for Co-generation ...Once Through Boiler “IF Series” A Comparison of KTE’s Line-up Boiler Water Tube Fire Tube Once-through (KF) Once-through

18© 2015 Kawasaki Heavy Industries, Ltd. All Rights Reserved

Hot Water Chiller “TSH Series”

The highest efficiency

COP (based on JIS) = 0.80

2-stage generation/condensationwhich structure has double generator and condenser(higher and lower pressure), it can be used to low temperature hot water (Min. 75’C).

Efficiency

Structure

Lower PressureGenerator

Higher PressureGenerator

Page 19: KAWASAKI Boiler and Absorption Chiller for Co-generation ...Once Through Boiler “IF Series” A Comparison of KTE’s Line-up Boiler Water Tube Fire Tube Once-through (KF) Once-through

19© 2015 Kawasaki Heavy Industries, Ltd. All Rights Reserved

Exhaust HeatFossil Fuel

Various energy sources can be utilized

Direct firing

Oil

Gas

Waste Hot Water

Gas Engine

Gas Turbine

Solar, Geo-thermal

Renewable Energy

HotWater

Steam

AbsorptionChiller

Chilled Water

SteamExhaust

Gas

SteamExhaust

Gas

HRSG

HRSG

Page 20: KAWASAKI Boiler and Absorption Chiller for Co-generation ...Once Through Boiler “IF Series” A Comparison of KTE’s Line-up Boiler Water Tube Fire Tube Once-through (KF) Once-through

20© 2015 Kawasaki Heavy Industries, Ltd. All Rights Reserved

Supply Record for Solar Cooling

Page 21: KAWASAKI Boiler and Absorption Chiller for Co-generation ...Once Through Boiler “IF Series” A Comparison of KTE’s Line-up Boiler Water Tube Fire Tube Once-through (KF) Once-through

21© 2015 Kawasaki Heavy Industries, Ltd. All Rights Reserved

Applying JCM Project in Indonesia

Cilegon

Cikampek

1High Efficiency Once-through boiler in Film Factory (2016)IF-4000 / 1 unit

2High Efficiency Once-through boiler in Golf Ball Factory (2016)IF-3000 / 1 unit

2) Boiler

Karawang

1) Chiller

1Absorption chiller in Chemical Factory (2018)NES-630A / 1 unit

Page 22: KAWASAKI Boiler and Absorption Chiller for Co-generation ...Once Through Boiler “IF Series” A Comparison of KTE’s Line-up Boiler Water Tube Fire Tube Once-through (KF) Once-through

22© 2015 Kawasaki Heavy Industries, Ltd. All Rights Reserved

Introduction of KTE Boilers Lineup

Water TubeBoiler

Multi TubeOnce-Trough

Steam Output Kg/h

10,0

00

7,0

00

6,0005,0004,0003,0002,0001,5001,000500

20,0

00

30,0

00

40,0

00

Smoke(Fire)Tube Boiler

HRSGSmoke Tube

Type

HRSGWater Tube

Type

HRSG Multi TubeOnce-Through

Type

400

2,500

5,000

606

2,516

1,000

4,000 30,000

10,000

10,000

5,000

35,000

KD Series

KS Series

IF Series

KF Series

KS-HR Series

RGA Series (KDF Series)

RF Series

1,677

5,031

Page 23: KAWASAKI Boiler and Absorption Chiller for Co-generation ...Once Through Boiler “IF Series” A Comparison of KTE’s Line-up Boiler Water Tube Fire Tube Once-through (KF) Once-through

23© 2015 Kawasaki Heavy Industries, Ltd. All Rights Reserved

Line up of KTE Chillers

Cooling Capacity kW(USRT)

3,517(1,000)

3,165(900)

2,814(800)

2,462(700)

2,110(600)

1,759(500)

1,407(400)

1,055(300)

703(200)

352(100)

DirectFired

StreamFired

Gene-LinkGas&

Hot Water

Hot Water

Triple Effect Direct Fired Absorption Chiller

NZ Series

NH, NU, NE Series

SIGMA MIDY Series

NES Series

Triple Effect Direct Fired Absorption Chiller

NZJ Series

NHJ Series

TZU Series

TSH Series

563(160)

281(80)

280(80)

141(40)

281(80)

510(145)

281(80)

281(80)

281(80)

281(80)

1,196(340)

3,517(1,000)

3,517(1,000)

246(70)

3,517(1,000)

1,090(310)

3,517(1,000)

3,517(1,000)

1,055(300)

1,759(500)