K. Genser FNAL/CD

16
Performance of Tevatron Flying Wire Detectors and Emittance Measurements for Stores 3050-3532 05/28/04 K. Genser FNAL/CD

description

Performance of Tevatron Flying Wire Detectors and Emittance Measurements for Stores 3050-3532 05/28/04. K. Genser FNAL/CD. Performance of FW Detectors. Stores 3050-3532 were analyzed excluding stores 3148-3325 when there was no E11 horizontal wire; - PowerPoint PPT Presentation

Transcript of K. Genser FNAL/CD

Page 1: K. Genser FNAL/CD

Performance of Tevatron Flying Wire Detectors

and Emittance Measurementsfor Stores 3050-3532

05/28/04

K. Genser

FNAL/CD

Page 2: K. Genser FNAL/CD

05/28/2004 K. Genser - TeV Flying Wires and Emittance Measurements

2

Performance of FW Detectors

• Stores 3050-3532 were analyzed excluding stores 3148-3325 when there was no E11 horizontal wire;

• The E11 proton detector has been showing signs of amplitude increase since March shutdown; other detectors have been stable;

• Despite the amplitude increase the detector does not show signs of saturation.

• The following plots are made using nominal lattice parameters and MDC dp/p formula as outlined in the note 888 & 656

Page 3: K. Genser FNAL/CD

05/28/2004 K. Genser - TeV Flying Wires and Emittance Measurements

3

Performance of FW E11 horizontal pbar detector

• The ratio of Bunch Amplitude times Sigma divided by SBDintensity versus Store for horizontal pbar detector is quite constant over time

Bunch Amplitude*Sigma divided by SBDintensity versus Store for horizontal pbar detector at 150 GeV.

Page 4: K. Genser FNAL/CD

05/28/2004 K. Genser - TeV Flying Wires and Emittance Measurements

4

Performance of FW E11 horizontal pbar detector

• Ratio of pass 1 over pass 2 of Bunch Amplitude times Sigma versus SBDintensity for horizontal pbar detector is quite constant and does not indicate that the detector is saturating

Ratio of pass 1 over pass 2 of Bunch Amplitude*Sigma versus SBDintensity for horizontal pbar detector at 150 GeV.

Page 5: K. Genser FNAL/CD

05/28/2004 K. Genser - TeV Flying Wires and Emittance Measurements

5

Performance of FW E11 horizontal proton detector

• The ratio of Bunch Amplitude times Sigma divided by SBDintensity versus Store for horizontal proton detector has been changing over time

Bunch Amplitude*Sigma divided by SBDintensity versus Store for horizontal proton detector at 150 GeV.

Page 6: K. Genser FNAL/CD

05/28/2004 K. Genser - TeV Flying Wires and Emittance Measurements

6

Performance of FW E11 horizontal proton detector

• Ratio of pass 1 over pass 2 of Bunch Amplitude times Sigma versus SBDintensity for horizontal proton detector is quite constant and does not indicate that the detector is saturating

Ratio of pass 1 over pass 2 of Bunch Amplitude*Sigma versus SBDintensity for horizontal proton detector at 150 GeV.

Page 7: K. Genser FNAL/CD

05/28/2004 K. Genser - TeV Flying Wires and Emittance Measurements

7

Injection Lattice Changes (pbars)

• Store 3424 lattice change is seen by horizontal Flying Wires

Page 8: K. Genser FNAL/CD

05/28/2004 K. Genser - TeV Flying Wires and Emittance Measurements

8

Injection Lattice Changes (protons)

• Store 3424 lattice change is seen by horizontal Flying Wires;

• Proton detectors indicate another smaller change before store 3528 (due to RF change?)

Page 9: K. Genser FNAL/CD

05/28/2004 K. Genser - TeV Flying Wires and Emittance Measurements

9

Injection Lattice Changes (pbars)

The ratio of E17/E11 Emittances not equal one indicates a discrepancy in the lattice functions

Page 10: K. Genser FNAL/CD

05/28/2004 K. Genser - TeV Flying Wires and Emittance Measurements

10

Injection Lattice Changes (protons)

The ratio of E17/E11 Emittances not equal one indicates a discrepancy in the lattice functions

Page 11: K. Genser FNAL/CD

05/28/2004 K. Genser - TeV Flying Wires and Emittance Measurements

11

Collision Lattice Changes (pbars)

• A change is visible before store 3487 with changes afterwards?

• A change before store 3528?

Page 12: K. Genser FNAL/CD

05/28/2004 K. Genser - TeV Flying Wires and Emittance Measurements

12

Collision Lattice Changes (protons)

• Store 3487 lattice change is seen by horizontal Flying Wires;

• Proton detectors indicate another change before store 3528 (most likely due to RF change not accounted for in the current dp/p formula)

Page 13: K. Genser FNAL/CD

05/28/2004 K. Genser - TeV Flying Wires and Emittance Measurements

13

Collision Lattice Changes (pbars)

The ratio of E17/E11 Emittances not equal one indicates a discrepancy in the lattice functions

Page 14: K. Genser FNAL/CD

05/28/2004 K. Genser - TeV Flying Wires and Emittance Measurements

14

Collision Lattice Changes (protons)

The ratio of E17/E11 Emittances not equal one indicates a discrepancy in the lattice functions

Page 15: K. Genser FNAL/CD

05/28/2004 K. Genser - TeV Flying Wires and Emittance Measurements

15

Collision Lattice/Emittance Changes

Page 16: K. Genser FNAL/CD

05/28/2004 K. Genser - TeV Flying Wires and Emittance Measurements

16

Flying Wires see lattice changes

• Both Injection and Collision lattice changes are visible using Flying Wires measurements

• The changes seem to be different for protons than for pbars