![Page 1: JJCA - Amazon Simple Storage Service · Project Manual For A New Health Building for TCAT Dickson Dickson, TN JJCA Project #15654.01 SBC # 166/000-04-2013M1 August 3rd, 2016 TFM Number:](https://reader031.fdocuments.us/reader031/viewer/2022020305/5c303a0b09d3f217118b56e5/html5/thumbnails/1.jpg)
JJCA
^ÇÇÉåÇìã= a~íÉW=ULNTLOMNS
qçW== ^ää=_áÇÇÉêë=çÑ=oÉÅçêÇ=
`ÅW== = = = = = =
cêçãW== pÜÉäÄó=_ÉÇÇáåÖÑáÉäÇ=J=gg`^=
mêçàÉÅíW== q`^q=aáÅâëçå=ENRSRQKMMF=J=`~ãéìë=fãéêçîÉãÉåíë=EMNF=
lïåÉê=mêçàÉÅí=@W= = = = = = =
pìÄàÉÅíW== q`^q=aáÅâëçå=J=kÉï=^ääáÉÇ=eÉ~äíÜ=_ìáäÇáåÖ=J=^ÇÇÉåÇìã=kçK=N=
Addendum No. 1
For TCAT Dickson
New Allied Health Building Nashville, Tennessee
SBC#166/000-04-2013M1
Johnson Johnson Crabtree Architects P.C. Project Number: 15654.00 (01)
Issued to - All Bidders of Record: Date Issued: August 17, 2016 This Addendum along with its attachments forms a part of the Contract Documents and modifies the Construction Documents, dated August 3, 2016, as noted below. The work reflected in this addendum is to be incorporated into the proposed Contract Sum and Time as if originally issued. Bidders must acknowledge receipt of this Addendum on the Bid Form. This Addendum consists of three (3) pages and twelve (12) attachments. This addendum is in three parts as follows: Part I Clarifications Part II Pertaining to the Project Manual. Part III Pertaining to the Drawings PART I – CLARIFICATIONS: 1. Several plan holders have noted discrepancies in the documentation of Bid Date and Pre-Bid
Meetings. The date/time for acceptance of bids shall be as directed on the TBR website (2 pm Wednesday September 7th). Pre-bid shall be August 23rd at 1 pm. See Part II for formal modifications to the relevant portions of the Project Manual.
2. See Part II and III below for all revisions to the construction documents due to State Fire Marshal review comments.
Johnson Johnson Crabtree Architects P.C.
4551 Trousdale Dr.
Nashville, TN 37204
tel 615-837-0656
fax 615-837-0657
81716
![Page 2: JJCA - Amazon Simple Storage Service · Project Manual For A New Health Building for TCAT Dickson Dickson, TN JJCA Project #15654.01 SBC # 166/000-04-2013M1 August 3rd, 2016 TFM Number:](https://reader031.fdocuments.us/reader031/viewer/2022020305/5c303a0b09d3f217118b56e5/html5/thumbnails/2.jpg)
ULNTLOMNS q`^q=aáÅâëçå=J=kÉï=^ääáÉÇ=eÉ~äíÜ=_ìáäÇáåÖ=J=^ÇÇÉåÇìã=kçK=N Page 2
PART II – PERTAINING TO THE PROJECT MANUAL: 1. Architectural
a. 00-0001 – Reference attached drawing for TFM Number and Project Number. b. 00-1116 – Reference attached for revised Bid Date. c. 00-2513 – Reference attached for revised Pre-Bid Conference Date.
2. Mechanical a. 28-3100 – Reference attached for revision to Signaling Appliances.
PART III – PERTAINING TO THE DRAWINGS: 1. Architectural
a. Cover – Reference attached drawing for TFM Number and Project Number. b. I-1.1 – Reference attached drawing for revisions to the Fire Code Analysis. c. A0.1 – Reference attached drawing for Life Safety clarifications.
i. Occupant load added in classroom #206 ii. Designation of space #200 to be a Hall in lieu of Corridor for clarity.
d. A6.2 – Reference attached drawing for added note to clarify specified UL-rated glazing system required to achieve ratings indicated.
2. Electrical a. E0.1 – Reference attached drawing for addition to Building Lighting Fixture
Schedule. b. E0.2 – Reference attached drawing for revision to panel schedule. c. E1.1 – Reference attached drawing for revisions in room #007 and #009. d. E3.1 – Reference attached drawing for added decibel ratings to all audible devices on
sheet.
ATTACHMENTS: (drawing sheets are tagged in title block with “Cumulative Sheet Re-Issue August 16, 2016”)
END OF ADDENDUM
List of Enclosures:
1. E3-1 - Systems First Floor.pdf 2. E1-1 - Lighting First Floor.pdf 3. E0-2 - Electrical Riser and Panel Schedules.pdf 4. E0-1 - Lighting Fixture Schedule.pdf
![Page 3: JJCA - Amazon Simple Storage Service · Project Manual For A New Health Building for TCAT Dickson Dickson, TN JJCA Project #15654.01 SBC # 166/000-04-2013M1 August 3rd, 2016 TFM Number:](https://reader031.fdocuments.us/reader031/viewer/2022020305/5c303a0b09d3f217118b56e5/html5/thumbnails/3.jpg)
ULNTLOMNS q`^q=aáÅâëçå=J=kÉï=^ääáÉÇ=eÉ~äíÜ=_ìáäÇáåÖ=J=^ÇÇÉåÇìã=kçK=N Page 3
5. 283100 fl - fire detection and alarm.pdf 6. 00-2513 USER-Pre-Bid Meetings and Site Investigation.pdf 7. 00-1116 TBR-Invitation to Bid.pdf 8. COVER.pdf 9. A6.2.pdf 10. A0.1.pdf 11. 00-0001 Inside Cover - Dickson.pdf 12. I-1.1 Index.pdf
![Page 4: JJCA - Amazon Simple Storage Service · Project Manual For A New Health Building for TCAT Dickson Dickson, TN JJCA Project #15654.01 SBC # 166/000-04-2013M1 August 3rd, 2016 TFM Number:](https://reader031.fdocuments.us/reader031/viewer/2022020305/5c303a0b09d3f217118b56e5/html5/thumbnails/4.jpg)
Project Manual For
A New Health Building for
TCAT Dickson Dickson, TN
JJCA Project #15654.01
SBC # 166/000-04-2013M1
August 3rd, 2016
TFM Number: 14500-A
Project Number: 2016-07-22-01
JOHNSON JOHNSON CRABTREE ARCHITECTS PC 4551 Trousdale Drive
Nashville, Tennessee 37204 Phone: 615-837-0656, Fax: 615-837-0657
INGRAM CIVIL ENGINEERING GROUP, LLC (Civil) 240 Wilson Pike Circle, Suite 200
Brentwood TN 37027 Phone: 615-370-7964, Fax: 615-370-1273
HEIBERT + BALL LAND DESIGN (Land) 1894 General George Patton Drive, Suite 400
Franklin, TN 37067 Phone: 615-376-2421, Fax: 615-376-2438
EMC STRUCTURAL ENGINEERS, P.C. (Struc) 4525 Trousdale Drive Nashville TN 37204
Phone: 615-781-8199, Fax: 615-781-4088
ENVISION ADVANTAGE, LLC (Mech)(Plumb)(Elec) 4633 Trousdale Drive
Nashville, Tennessee 37204 Phone: 615- 661-6211, Fax: 615-661-7574
Cumulative Sheet Re-Issue
81616
![Page 5: JJCA - Amazon Simple Storage Service · Project Manual For A New Health Building for TCAT Dickson Dickson, TN JJCA Project #15654.01 SBC # 166/000-04-2013M1 August 3rd, 2016 TFM Number:](https://reader031.fdocuments.us/reader031/viewer/2022020305/5c303a0b09d3f217118b56e5/html5/thumbnails/5.jpg)
ADDENDUM 1
A New Health Building for TCAT Dickson JJCA #15654.01 SBC #166/000-04-2013M1 July 2015 OFD s001116 page 1 of 1
Invitation to Bid 00 11 16 - 1
INVITATION TO BID
PROJECT: A New Health Building for Tennessee College of Applied Technology, Dickson SBC #166/000-04-2013M1
DESIGNER: Johnson Johnson Crabtree Architects PC 4551 Trousdale Dr Nashville, TN 37204 615-837-0656 Contact: Shelby Beddingfield
BRIEF PROJECT DESCRIPTION: Construction of an approximately 11,800 square foot, one story, educational facility at the Campus and houses the allied health programs.
Bids are invited for a General Contract for the Work of the above project.
Bids will be received by the State of Tennessee at Tennessee Board of Regents (Central Office) Office of Facilities Development Suite 358 - Genesco Office Park 1415 Murfreesboro Road Nashville, Tennessee 37217-2833
until 2:00pm local time Wednesday 7 September 2016
at which time and place bids will be publicly opened. Bids sent by mail should be directed to the attention of Tammy Ray
Bidding documents may be examined at the Designer's office and at the following Plan Rooms: iSqFt Plan Room & TN AGC Nashville, Tennessee Builders Exchange of Tennessee Nashville, Tennessee Minority Business Development Center Nashville, Tennessee
Electronic copies of the Bidding Documents may be obtained from the Designer in accordance with the Instructions to Bidders upon request and without deposit.
Bidders submitting bids equal to or greater than $25,000 in value are required to be licensed in accordance with state law. A statement of public contract crime status is required in the Bid form. A five percent (5%) Bid Security is required. Non-Discrimination policy applies to this project.
The Owner reserves the right to waive informalities and to reject bids.
![Page 6: JJCA - Amazon Simple Storage Service · Project Manual For A New Health Building for TCAT Dickson Dickson, TN JJCA Project #15654.01 SBC # 166/000-04-2013M1 August 3rd, 2016 TFM Number:](https://reader031.fdocuments.us/reader031/viewer/2022020305/5c303a0b09d3f217118b56e5/html5/thumbnails/6.jpg)
PRE-BID MEETINGS AND SITE INVESTIGATION 00-2513-1A New Health Building for TCAT Dickson - 15654.01
Addendum 1
SECTION 00-2513PRE-BID MEETINGS AND SITE INVESTIGATION
PART 1 SUMMARY
1.01 THE INSTRUCTIONS IN THIS DOCUMENT AMEND OR SUPPLEMENT THEINSTRUCTIONS TO BIDDERS AND OTHER PROVISIONS OF THE BIDDING ANDCONTRACT DOCUMENTS.
1.02 DOCUMENT INCLUDES
A. Site Assessment1. Site Examination2. Prebid Conference
PART 2 SITE ASSESSMENT
2.01 SITE EXAMINATION
A. Examination of the project site before submitting a bid is not required.
B. A visit to the project site has been arranged for bidders as noted in the pre-bidconference.
2.02 PREBID CONFERENCE
A. A bidders conference has been scheduled for 1 p.m. on the 23rd day of August at thelocation of the project.
B. Representatives of Architect will be in attendance.
C. Information relevant to the Bid Documents will be recorded in an Addendum, issued toBid Document recipients.
END OF SECTION
![Page 7: JJCA - Amazon Simple Storage Service · Project Manual For A New Health Building for TCAT Dickson Dickson, TN JJCA Project #15654.01 SBC # 166/000-04-2013M1 August 3rd, 2016 TFM Number:](https://reader031.fdocuments.us/reader031/viewer/2022020305/5c303a0b09d3f217118b56e5/html5/thumbnails/7.jpg)
PRE-BID MEETINGS AND SITE INVESTIGATION 00-2513-2A New Health Building for TCAT Dickson - 15654.01
![Page 8: JJCA - Amazon Simple Storage Service · Project Manual For A New Health Building for TCAT Dickson Dickson, TN JJCA Project #15654.01 SBC # 166/000-04-2013M1 August 3rd, 2016 TFM Number:](https://reader031.fdocuments.us/reader031/viewer/2022020305/5c303a0b09d3f217118b56e5/html5/thumbnails/8.jpg)
FIRE DETECTION AND ALARM 28 3100-1 A New Health Building for TCAT Dickson - 15654.01
Addendum 1
SECTION 28 3100
FIRE DETECTION AND ALARM
PART 1 - GENERAL
1.01 SUMMARY
A. Fire alarm control panel.
B. Manual fire alarm stations.
C. Automatic smoke and heat detectors.
D. Duct mounted smoke detectors.
E. Fire alarm signaling appliances.
F. Auxiliary fire alarm equipment.
1.02 SUBMITTALS
A. Provide submittals in accordance with Division 1.
B. Shop Drawings: Provide complete system point-to-point wiring diagram including conduit and wire, showing each device and wiring connection required. Indicate locations of all control relays.
C. Product Data: Provide electrical characteristics and connection requirements.
D. Provide annunciator type, configuration and point/zone identification Coordination Drawings.
E. Provide battery calculations and notification appliance circuit calculations.
1.03 RELATED SECTIONS
A. Division 26 Section “Common Work Results For Electrical”.
1.04 QUALITY ASSURANCE
A. Installer Qualifications: Personnel shall be trained and certified by manufacturer for installation of units required for this Project.
B. NFPA Certification: Obtain certification according to NFPA 72 by a UL-listed alarm company.
1.05 SYSTEM DESCRIPTION
A. Furnish, install and connect a microprocessor controlled, intelligent reporting fire alarm
![Page 9: JJCA - Amazon Simple Storage Service · Project Manual For A New Health Building for TCAT Dickson Dickson, TN JJCA Project #15654.01 SBC # 166/000-04-2013M1 August 3rd, 2016 TFM Number:](https://reader031.fdocuments.us/reader031/viewer/2022020305/5c303a0b09d3f217118b56e5/html5/thumbnails/9.jpg)
FIRE DETECTION AND ALARM 28 3100-2 A New Health Building for TCAT Dickson - 15654.01
Addendum 1
system required to form a complete coordinated system ready for operations. It shall include, but not be limited to, alarm initiating devices, alarm notification appliances, control panel, auxiliary control devices, annunciators, and necessary wiring as shown on the drawings, specified herein and as required for a complete and operable system.
B. The fire alarm system shall comply with requirements of NFPA Standard No. 72 for protected premises signaling systems except as modified and supplemented by this specification. The system shall be electrically supervised and monitor the integrity of all conductors.
C. Control panel shall be microprocessor based utilizing resident, non-volatile memory. Operating system shall provide logic and supervision for closed loop initiating device circuits, indicating device circuits, operating power and control circuits. System shall be capable of remote programming for downloading to accommodate system changes.
D. Alarm, trouble and supervisory signals from all intelligent reporting devices shall be encoded onto an NFPA Style 4 (Class B) signaling line circuit. Initiation device circuits shall be wired NFPA Style Y, (Class B). Indicating appliance circuits shall be wired Style Y (Class B.) Digitized electronic signals shall employ check digits or multiple polling. Alarm signals arriving at the main FACP shall not be lost following a power failure until the alarm signal is processed and recorded.
E. The facility shall have an LCD annunciator(s) which annunciates alarm and/or trouble condition.
1.06 SEQUENCE OF OPERATIONS
A. When a fire alarm or trouble condition is detected and reported by one of the system initiating devices or appliances, the following functions shall immediately occur:
1. The System Alarm LED shall flash until the alarm is acknowledged. Once acknowledged the LED shall be illuminated continuously until the system is reset or another alarm is received. The receipt of another alarm shall cause the LED to flash.
2. A local audible pulsing signal in the control panel shall sound until the system is silenced.
3. The 80-character LCD display shall indicate all information associated with the Fire Alarm condition, including the type of alarm point and its location within the protected premises. LED display shall be capable of displaying multiple alarm and/or trouble conditions through the scrolling feature.
4. Historical storage equipment shall log the information associated each new Fire Alarm Control Panel condition, along with time and date of occurrence.
5. All system output programs assigned via control-by-event logic to be activated by the particular point in alarm shall be executed, and the associated System Outputs (alarm indicating appliances and/or relays) shall be activated.
B. Initiation of ceiling mounted smoke detectors shall send a signal to the control panel which shall initiate the following functions:
1. Initiate a general alarm.
![Page 10: JJCA - Amazon Simple Storage Service · Project Manual For A New Health Building for TCAT Dickson Dickson, TN JJCA Project #15654.01 SBC # 166/000-04-2013M1 August 3rd, 2016 TFM Number:](https://reader031.fdocuments.us/reader031/viewer/2022020305/5c303a0b09d3f217118b56e5/html5/thumbnails/10.jpg)
FIRE DETECTION AND ALARM 28 3100-3 A New Health Building for TCAT Dickson - 15654.01
Addendum 1
2. Release doors throughout the facility held open by electric door holders. 3. Shut down HVAC fans. 4. Close smoke dampers associated with HVAC fans which shutdown. 5. Annunciate specific point at the fire alarm annunciator. 6. Release electrically locked egress doors.
C. Initiation of a manual pull station shall send a signal to the control panel, which shall initiate the following functions:
1. Initiate a general alarm. 2. Release doors throughout the facility held open by electric door holders. 3. Shut down HVAC fans. 4. Close smoke dampers associated with HVAC fans which shutdown. 5. Annunciate specific point at the fire alarm annunciator. 6. Release electrically locked egress doors.
D. Initiation of a duct mounted smoke detector shall send a signal to the control panel, which shall initiate the following functions:
1. Initiate a general alarm. 2. Release doors throughout the facility held open by electric door holders. 3. Shut down HVAC fans. 4. Close smoke dampers associated with HVAC fans which shutdown. 5. Annunciate specific point at the fire alarm annunciator. 6. Release electrically locked egress doors.
E. Initiation of an Automatic Sprinkler System water flow switch shall send a signal to the control panel, which shall initiate the following functions:
1. Initiate a general alarm. 2. Release doors throughout the facility held open by electric door holders. 3. Shut down HVAC fans. 4. Close smoke dampers associated with HVAC fans which shutdown. 5. Annunciate specific point on fire alarm annunciator. 6. Release electrically locked egress doors.
1.07 MONITORING/TROUBLE INDICATION
A. Assign a monitor point to the following devices/systems to indicate abnormal conditions.
1. Automatic sprinkler tamper and flow switches. 2. Dry pipe sprinkler systems.
B. Supervise the automatic dialer
PART 2 - PRODUCTS
2.01 MANUFACTURERS
![Page 11: JJCA - Amazon Simple Storage Service · Project Manual For A New Health Building for TCAT Dickson Dickson, TN JJCA Project #15654.01 SBC # 166/000-04-2013M1 August 3rd, 2016 TFM Number:](https://reader031.fdocuments.us/reader031/viewer/2022020305/5c303a0b09d3f217118b56e5/html5/thumbnails/11.jpg)
FIRE DETECTION AND ALARM 28 3100-4 A New Health Building for TCAT Dickson - 15654.01
Addendum 1
A. Simplex
B. Notifier
C. Edwards
D. Siemens Ceberus.
2.02 EQUIPMENT AND MATERIAL, GENERAL:
A. All equipment and components shall be new, and the manufacturer’s current model. The materials, appliances, equipment and devices shall be tested and listed by a nationally recognized approvals agency for use as part of a protected premises protective signaling (fire alarm) system.
B. All equipment and components shall be installed in strict compliance with manufacturers’ recommendations. Consult the manufacturer’s installation manuals for all wiring diagrams, schematics, physical equipment sizes, etc., before beginning system installation.
C. All equipment shall be attached to walls and ceiling/floor assemblies and shall be held firmly in place (e.g., detectors shall not be supported solely by suspended ceilings). Fasteners and supports shall be adequate to support the required load.
2.03 MAIN FIRE ALARM CONTROL PANEL
A. The FACP shall be equal to a Simplex 4100 and shall contain a microprocessor based Central Processing Unit (CPU). The CPU shall communicate with and control the following types of equipment used to make up the system: intelligent detectors, addressable modules, annunciators, and other system controlled devices. Must be able to monitor trouble signal from existing system.
B. System Capacity and General Operation
1. The control panel shall be capable of monitoring up to 1000 intelligent devices. 2. The Fire Alarm Control Panel shall include a full-featured operator interface
control and annunciation panel that shall include a backlit Liquid Crystal Display, individual, color-coded system status LEDs, and an alphanumeric keypad for the Field Programming and Control of the Fire Alarm System.
3. All programming of the system shall be achieved without special equipment and without interrupting the alarm monitoring functions of the Fire Alarm Control Panel.
4. The FACP shall provide the following features: a. Drift Compensation to extend detector accuracy over life. b. Sensitivity Test, meeting requirements of NFPA 72. c. Maintenance Alert to warn of excessive compensation. d. System Status Reports to display. e. Alarm Verification, with verification counters. f. Non-Alarm points for general (non-fire) control. g. Walk Test. h. Security Monitor Points, meeting requirements of UL 1076.
![Page 12: JJCA - Amazon Simple Storage Service · Project Manual For A New Health Building for TCAT Dickson Dickson, TN JJCA Project #15654.01 SBC # 166/000-04-2013M1 August 3rd, 2016 TFM Number:](https://reader031.fdocuments.us/reader031/viewer/2022020305/5c303a0b09d3f217118b56e5/html5/thumbnails/12.jpg)
FIRE DETECTION AND ALARM 28 3100-5 A New Health Building for TCAT Dickson - 15654.01
Addendum 1
i. Control-By-Time for non-fire operations, with holidays. 5. Any device in the system may be Enabled or Disabled through the system
keypad. 6. The system shall be able to display the following point status diagnostic
functions: a. Device Status. b. Device Type c. Custom Device Label. d. Present analog reading (in percent-per-foot obscuration). e. Analog Detector Alarm level, in percent-per-foot. f. Device Zone Assignments g. All Program Parameters.
C. Central Processor
1. The Microprocessor unit shall communicate with, monitor, and control all external interfaces with the control panel. It shall include EPROM for system program storage; non-volatile memory for building-specific program storage; and a “watch dog” timer circuit to detect and report microprocessor failure.
2. The Microprocessor unit shall contain and execute all control-by-event programs for specific action to be taken if an alarm condition is detected by the system. Such control-by-event programs shall be held in non-volatile programmable memory, and shall not be lost even if system primary and secondary power failure occurs.
3. The Microprocessor Unit shall also provide a Real-Time clock for time annotation of system displays, printer, and history file. The Time-of-Day and date shall not be lost if system primary and secondary power supplies fail. The Real Time Clock may also be used to control non-fire functions at programmed item-of-day, day-of-week, and day-of-year.
D. Display
1. The Display shall provide all the controls and indicators used by the system operator and may also be used to program all system operational parameters.
2. The Display shall include status information and custom alphanumeric labels for all Detectors, Addressable Modules, and Software zones.
3. The Display shall provide an 80-character back-lit alphanumeric Liquid Crystal Display (LCD). It shall also provide 5 Light-Emitting-Diodes (LEDs), that will indicate the status of the following system parameters: AC POWER, SYSTEM ALARM, SYSTEM TROUBLE, SIGNAL SILENCED, SUPERVISORY, and PRE-ALARM.
4. The Display shall provide a 21-key touch key-pad with control capability to command all system functions, entry of any alphabetic or numeric information, and field programming. Two different password levels shall be provided to prevent unauthorized system control or programming.
5. The Display shall include the following operator functions: SIGNAL SILENCE, RESET, DRILL, and ACKNOWLEDGE.
E. SLC Loop Interface
![Page 13: JJCA - Amazon Simple Storage Service · Project Manual For A New Health Building for TCAT Dickson Dickson, TN JJCA Project #15654.01 SBC # 166/000-04-2013M1 August 3rd, 2016 TFM Number:](https://reader031.fdocuments.us/reader031/viewer/2022020305/5c303a0b09d3f217118b56e5/html5/thumbnails/13.jpg)
FIRE DETECTION AND ALARM 28 3100-6 A New Health Building for TCAT Dickson - 15654.01
Addendum 1
1. The SLC Interface shall provide power to, and communicate with, all Addressable Modules over a single pair of wires. This SLC Loop shall be capable of operation as NFPA Style 4, Style 6, or Style 7.
2. he detector software shall meet NFPA 72 requirements and be certified by UL as a calibrated sensitivity test instrument.
3. The detector software shall allow manual or automatic sensitivity adjustment.
F. Serial Interfaces
1. An EIA-232 interface between the Fire Alarm Control Panel and UL Listed Electronic Data Processing (EDP) peripherals shall be provided. The EIA-232 interface shall allow the use of future printers, CRT monitors, and PC compatible computers.
2. The EIA-485 port for the serial connection of the optional Annunciators and re-mote LCD displays shall be provided. The EIA-485 interface may be used for network connection to a Proprietary Receiving Unit.
G. Enclosures:
1. The control panel shall be housed in a UL listed cabinet suitable for surface or semi-flush mounting. Cabinet and front shall be corrosion protected, given a rust-resistant prime coat, and manufacturer’s standard finish.
2. The door shall provide a key lock and shall include a glass or other transparent opening for viewing of all indicators.
H. Additional Features:
1. All interfaces and associated equipment are to be protected so that they will not be affected by voltage surges or line transients consistent with UL standard 864.
2. Plug-in modules shall be provided for a Digital Alarm Communicator/Transmitter. 3. For ease of service all wiring terminal blocks for I/O interfaces shall be the plug-
in type and have sufficient capacity for 18 to 12 AWG wire. Terminal blocks shall be permanently mounted inside all enclosures.
I. Power Supply:
1. The Power Supply shall operate on 120 VAC, 60 Hz, and shall provide all necessary power for the FACP. It shall provide 5.0 amps of usable indicating appliance power, using a switching 24 VDC regulator. Provide a battery charger for 24 hours of standby using dual-rate techniques for fast battery recharge. Provide a very low frequency sweep earth detect circuit, capable of detecting earth faults on sensitive addressable modules.
2.04 INIITIATING DEVICES
A. Manual Station: Addressable semi-Flush mounted, non-coded type, double action manual station. Spot Heat Detector: Fixed temperature, rated 135 degrees F.
B. Spot Heat Detector: Fixed temperature, rated 135 degrees F.
C. Ceiling Mounted Smoke Detector : Photoelectric type with adjustable sensitivity, plug-in
![Page 14: JJCA - Amazon Simple Storage Service · Project Manual For A New Health Building for TCAT Dickson Dickson, TN JJCA Project #15654.01 SBC # 166/000-04-2013M1 August 3rd, 2016 TFM Number:](https://reader031.fdocuments.us/reader031/viewer/2022020305/5c303a0b09d3f217118b56e5/html5/thumbnails/14.jpg)
FIRE DETECTION AND ALARM 28 3100-7 A New Health Building for TCAT Dickson - 15654.01
Addendum 1
base, and visual indication of detector actuation, suitable for mounting on 4 inch outlet box. Detector bases shall accommodate either Photoelectric or Ionization type detectors.
D. Duct Mounted Smoke Detector: Photoelectric type with duct sampling tubes extending width of duct, and visual indication of detector actuation, in duct-mounted housing. Provide a key-operated NORMAL-RESET-TEST switch for remote mounting.
E. All smoke and heat detectors shall be intelligent addressable devices.
2.05 SIGNALING APPLIANCES
A. All signaling appliances shall comply with ADA guidelines and NFPA 72.
B. Electronic Chime: Electronic chimes shall operate on 24 VDC nominal. Electronic chimes shall be field adjustable to provide different tones and sound levels. Maximum sound level shall be at least 60 dBA measured at 10 feet from the device.
C. Alarm Lights: Strobe lamp and flasher with red lettered "FIRE" on white lens. Alarm lights shall operate on 24 VDC. Candela ratings shall be field selectable between 15, 30, 75, and 110cd.
D. Audible/Visual Combination Devices shall meet the applicable requirements outlined above for audibility and visibility.
E. Alarm Horn: Electronic horns shall operate on 24 VDC nominal. Electronic horns shall be field adjustable to provide different tones and sound levels. Maximum sound level shall be at least 80 dBA measured at 10 feet from the device. Provide integral strobe lamp and flasher with red lettered "FIRE" on white lens.
F. Voice/Tone Notification Appliances:
1. Comply with UL 1480. 2. Speakers for Voice Notification: Locate speakers for voice notification to provide
the intelligibility requirements of the "Notification Appliances" and "Emergency Communications Systems" chapters in NFPA 72.
3. High-Range Units: Rated 2 to 15 W. 4. Low-Range Units: Rated 1 to 2 W. 5. Mounting: semi-recessed. 6. Matching Transformers: Tap range matched to acoustical environment of
speaker location.
F. Audible and visual signals shall be wired separately.
G. All fire alarm signaling devices shall have a white finish.
2.06 AUXILIARY DEVICES
A. Door Release: Wall mounted magnetic door holder with integral diodes to reduce buzzing. Coil voltage: 24 VDC.
![Page 15: JJCA - Amazon Simple Storage Service · Project Manual For A New Health Building for TCAT Dickson Dickson, TN JJCA Project #15654.01 SBC # 166/000-04-2013M1 August 3rd, 2016 TFM Number:](https://reader031.fdocuments.us/reader031/viewer/2022020305/5c303a0b09d3f217118b56e5/html5/thumbnails/15.jpg)
FIRE DETECTION AND ALARM 28 3100-8 A New Health Building for TCAT Dickson - 15654.01
Addendum 1
B. Monitor Modules: Provide sufficient monitor modules to monitor N.O. dry contact devices specified.
C. Addressable Control Relays: Provide sufficient SPDT Form C Addressable control relays to accomplish control functions specified. All control functions specified shall be accomplished via addressable control relays. The use of auxiliary contacts on individual initiating devices for control purposes is not acceptable. Where the burden of the device being controlled exceeds the rating of the addressable relay, provide an auxiliary control relay with a minimum rating of 10 amps at 120V.
D. Isolator Module:
1. Isolator Modules shall be provided to automatically isolate wire-to-wire short circuits on an SLC loop. The Isolator Module shall limit the number of modules or detectors that may be rendered inoperative by a short circuit fault on the SLC Loop. At least one isolator module shall be provided for each floor or protected zone of the building.
2. If a wire-to-wire short occurs, the Isolator Module shall automatically open-circuit (disconnect) the SLC loop. When the short circuit condition is corrected, the Isolator Module shall automatically reconnect the isolated section of the SLC loop. It shall provide a single LED that shall flash to indicate that the Isolator is operational and shall illuminate steadily to indicate that a short circuit condition has been detected and isolated.
E. Transient voltage surge suppression (TVSS): Provide an EFI 400 OEM/120V TVSS Device for the FACP and each exterior circuit.
2.07 ANNUNCIATION AND NOTIFICATION
A. Remote Station Signal Transmitter: Electrically Supervised Digital Alarm Communicator Transmitter (DACT), capable of transmitting alarm and trouble signals over telephone lines to central station receiver. DACT shall meet all requirements of NFPA 71.
B. LCD Alphanumeric Display Annunciator.
1. The Alphanumeric display annunciator shall be a supervised, local or remotely located back-lit LCD display containing a minimum of eighty (80) characters for alarm annunciation in clear English text.
2. The LCD annunciator shall display all alarm and trouble conditions in the system. 3. The annunciator shall connect to an EIA 485 interface. 4. Up to 4 LCD annunciators may be connected to the interface, each with
Acknowledge, Silence and Reset controls for the FACP.
2.08 BATTERIES
A. Battery capacity shall comply with NFPA-72. Batteries shall be 12 volt, Gell-Cell type and shall have sufficient capacity to power the fire alarm system for not less than twenty-four hours plus 5 minutes of system wide alarm upon a normal AC power failure. The batteries are to be completely maintenance free. Provide battery
![Page 16: JJCA - Amazon Simple Storage Service · Project Manual For A New Health Building for TCAT Dickson Dickson, TN JJCA Project #15654.01 SBC # 166/000-04-2013M1 August 3rd, 2016 TFM Number:](https://reader031.fdocuments.us/reader031/viewer/2022020305/5c303a0b09d3f217118b56e5/html5/thumbnails/16.jpg)
FIRE DETECTION AND ALARM 28 3100-9 A New Health Building for TCAT Dickson - 15654.01
Addendum 1
calculation for system with submittal.
PART 3 - EXECUTION
3.01 INSTALLATION
A. Install products in accordance with manufacturer’s instructions.
B. Ceiling Mounted Smoke Detectors:
1. Corridor smoke detectors shall NOT exceed 30 feet on center. 2. Detectors shall NOT be located within three feet of a supply air grille. 3. Corridor smoke detectors located at cross corridor smoke doors shall be located
a maximum of five feet on both sides of the door.
C. Duct Mounted Smoke Detectors
1. Furnish quantity of duct mounted detectors as indicated on the Division 23 drawings.
2. Detectors shall be installed by Division 23 and connected by Division 26. 3. Sampling tube shall extend the full least across duct and be supported on both
ends.
D. Water Flow and Tamper Switches:
1. Connect water flow and tamper switches furnished and installed by Division 22 and Division 23.
E. Mount end-of-line device in a separate box adjacent to last device in circuit.
F. Install all fire alarm system wiring as open wiring (i.e. conduit stub-ups and plenum rated cable.
G. Fire alarm wiring shall comply with NEC Article 760. Wiring shall be color coded.
H. Include service of certified technician to supervise installation, adjustments, final connections, and system testing. The manufacturer shall have technician available on a 24 hour basis within 150 miles of this project.
I. Provide owner’s personnel with a minimum of one day of hands on training for systems operation and maintenance.
J. Visual alarms shall be wired separately from audible alarms so that visual alarms shall continue to flash after the alarm condition has been silenced.
K. Coordinate with the local fire alarm system monitoring service regarding specific local requirements. Provide ALL equipment required for remote supervision of the system.
L. Provide TVSS protection on all exterior circuits
![Page 17: JJCA - Amazon Simple Storage Service · Project Manual For A New Health Building for TCAT Dickson Dickson, TN JJCA Project #15654.01 SBC # 166/000-04-2013M1 August 3rd, 2016 TFM Number:](https://reader031.fdocuments.us/reader031/viewer/2022020305/5c303a0b09d3f217118b56e5/html5/thumbnails/17.jpg)
FIRE DETECTION AND ALARM 28 3100-10 A New Health Building for TCAT Dickson - 15654.01
Addendum 1
M. Fire Alarm control relays used to control fans, shunt trip circuit breakers, etc. shall be located within three feet of the device to be controlled (i.e. starter, circuit breaker controller, etc.). Fire alarm wiring up to the fire alarm control relay shall be supervised.
N. The address shall be permanently marked at each device. Smoke detectors, heat detectors, and duct mounted smoke detectors shall marked on the base.
O. SLC and NAC circuits shall have 20% spare capacity.
3.02 TESTING AND CERTIFICATIONS.
A. After system installation is completed and all devices have been successfully tested, provide systems demonstration in the presence of engineer and authority having jurisdiction. Make necessary system changes as required by the engineer and AHJ.
B. Prepare a fire alarm system certification equal to that outlined in NFPA 72 and as required by the AHJ. Submit to AHJ upon request. Include certification in O&M manuals.
C. After completion of all smoke detectors, test each detector’s sensitivity to determine if it falls within manufacturer’s acceptable range. Replace detectors that test out of range. Prepare a typed report with name and signature of the person(s) performing the test. The report shall include the following:
1. That test out of range. Prepare a typed report with name and signature of the person(s) performing the test. The report shall include the following:
2. Uniquely identify each smoke detector. 3. Location of smoke detector. 4. Sensitivity value - field test 5. Sensitivity value - factory test 6. Within limits - Yes or No
END OF SECTION 28 3100
![Page 18: JJCA - Amazon Simple Storage Service · Project Manual For A New Health Building for TCAT Dickson Dickson, TN JJCA Project #15654.01 SBC # 166/000-04-2013M1 August 3rd, 2016 TFM Number:](https://reader031.fdocuments.us/reader031/viewer/2022020305/5c303a0b09d3f217118b56e5/html5/thumbnails/18.jpg)
gg`^=mêçàÉÅí=@W
4551 Trousdale Drive
Nashville, TN 37204
Johnson JohnsonCrabtree Architects P.C.
JJCA
tel
fax
615.837.0656
615.837.0657
NRSRQKMN
^ìÖìëí=PI=OMNS
TCAT DicksonDickson, TN
^=kÉï=eÉ~äíÜ=_ìáäÇáåÖ=cçêW
`lkpqor`qflk=al`rjbkqp=J=p_`=@NSSLMMMJMQJOMNPjN
`lkpqor`qflk=al`rjbkqp=J=p_`=@NSSLMMMJMQJOMNPjN
`fsfi=bkdfkbbo
Ingram Civil EngineeringOQM=táäëçå=máâÉ=`áêÅäÉ=pìáíÉ=OMM
_êÉåíïççÇI=qk=PTMOT
lÑÑáÅÉ=SNRJPTMJTVSQ
`çåí~ÅíW=_ìÄÄ~=fåÖê~ã
pqor`qro^i=bkdfkbbo
EMC Structural Engineers, P.C.QROR=qêçìëÇ~äÉ=aêáîÉ
k~ëÜîáääÉI=qk=PTOMQ
lÑÑáÅÉ=SNRJTUNJUNVV
`çåí~ÅíW=a~å=_çêëçë
ifcb=p^cbqvL`labp=`lkpriq^kq
Fire Protection AssociatesQOMR=eáääëÄçêç=oÇK=pìáíÉ=OMV
k~ëÜîáääÉI=qk=PTONR
lÑÑáÅÉ=SNRJOVOJUUUM
`çåí~ÅíW=_áää=píÉÑÑÉåÜ~ÖÉå
fkqboflop
WPI StudioPMMN=aìåÉÇáå=`çìêí
läÇ=eáÅâçêóI=qk=PTNPU
lÑÑáÅÉ=SNRJTTPJONUM
`çåí~ÅíW=eÉ~íÜÉê=cìääáåÖíçå
ltkbo
TN Board of RegentsNQNR=jìêÑêÉÉëÄçêç=oç~Ç
k~ëÜîáääÉI=qk=PTONT
lÑÑáÅÉ=SNRJPSSJQQTS
`çåí~ÅíW=qêáëÜ=tÜáíäçÅâ
jmb=bkdfkbbop
Envision Advantage, LLCQSPP=qêçìëÇ~äÉ=aêáîÉ
k~ëÜîáääÉI=qk=PTOMQ
lÑÑáÅÉ=SNRJSSNJSONN
`çåí~ÅíW=oáÅÜ=_~ÇÉå
c^`fifqv
TCAT - DicksonTQM=eáÖÜï~ó=QS
aáÅâëçåI=qk=PTMRR
lÑÑáÅÉ=SNRJQQNJSOOM
`çåí~ÅíW=^êêáí~=pìããÉêë
`lkq^`qW=jf`e^bi=pmb`h
qcj=kìãÄÉêW=NQRMMJ^
mêçàÉÅí=kìãÄÉêW=OMNSJMTJOOJMN
Cumulative Sheet Re-Issue
81616
![Page 19: JJCA - Amazon Simple Storage Service · Project Manual For A New Health Building for TCAT Dickson Dickson, TN JJCA Project #15654.01 SBC # 166/000-04-2013M1 August 3rd, 2016 TFM Number:](https://reader031.fdocuments.us/reader031/viewer/2022020305/5c303a0b09d3f217118b56e5/html5/thumbnails/19.jpg)
q`^q=J=af`hplk=J=jbaf`^i=bar`^qflk=_rfiafkd
aáÅâëçåI=qÉååÉëëÉÉ
^êÅÜáíÉÅíìê~ä=cáêÉ=p~ÑÉíó=`çÇÉ=^å~äóëáë= o=b=s=f=p=b=a=EPF
cáêÉ=p~ÑÉíó=`çåÅÉéíW
aÉëáÖå=~=åÉï=ãáñÉÇ=çÅÅìé~åÅó=ÄìáäÇáåÖ=ïáíÜ=~Çìäí=Åä~ëëÉë=çÑ=
åçåÅçãÄìëíáÄäÉ=ÅçåëíêìÅíáçåK=qïç=çÑ=íÜÉ=Åä~ëëêççãë=ÉñÅÉÉÇ=TRM=ëèK=
ÑíKLQV=çÅÅìé~åíë=~åÇ=~êÉ=ÅçåëáÇÉêÉÇ=~ëëÉãÄäó=ëé~ÅÉë=Ef_`=PMPKNFK=
qÜÉ=åçåëÉé~ê~íÉÇ=ìëÉ=éÉê=f_`=RMUKPKO=áë=ìëÉÇ=ïáíÜ=^ëëÉãÄäó=ÄÉáåÖ=
íÜÉ=ëíêáÅíÉê=ÜÉáÖÜíL~êÉ~=~ääçï~ÄäÉK
qÜÉ=Ä~ëÉ=~ääçï~ÄäÉ=~êÉ~=áë=VIRMM=ëèK=ÑíK=ïáíÜ=qóéÉ=ff=_=ÅçåëíêìÅíáçåK=^ÇÇáíáçå~ä=~êÉ~=áë
éçëëáÄäÉ=ìëáåÖ=íÜÉ=Ñêçåí~ÖÉ=áåÅêÉ~ëÉ=áå=RMSKO=~ë=ÑçääçïëW
fEÑF=Z=xcLm=J=MKORz=tLPM
Z=xROMLROM=J=MKORz=PMLPM
Z xMKTRz=N
Z==MKTR
MKTR=ñ=VIRMM=Z==TINOR=ëèK=ÑíK
qÜÉ=íçí~ä=~ääçï~ÄäÉ=~êÉ~=áë=íÜÉå=VIRMM=H=TINOR=Z=NSISOR=ëèK=ÑíK
lìíëáÇÉ=Éñáíë=~êÉ=éêçîáÇÉÇ=~í=íÜêÉÉ=äçÅ~íáçåë=áå=íÜÉ=ÄìáäÇáåÖK=qïç=Åä~ëëêççãë=~åÇ=íÜÉ=ä~Ä
É~ÅÜ=Ü~îÉ=~å=çìíëáÇÉ=Çççê=Ñçê=ÉÖêÉëëI=~äëçK
fK ^ééäáÅ~ÄäÉ=`çÇÉëW
pí~íÉ=cáêÉ=j~êëÜ~ä=J
^K OMMS=fåíÉêå~íáçå~ä=_ìáäÇáåÖ=`çÇÉ=EÉñÅäìÇáåÖ=`ÜëK=NN=C=
OTF
_K OMMS=fåíÉêå~íáçå~ä=cáêÉ=`çÇÉ
`K OMMS=fåíÉêå~íáçå~ä=cìÉä=d~ë=`çÇÉ
aK OMMS=fåíÉêå~íáçå~ä=jÉÅÜ~åáÅ~ä=`çÇÉ
bK= OMMS=fåíÉêå~íáçå~ä=båÉêÖó=`çåëÉêî~íáçå=`çÇÉL^peo^b=
pí~åÇ~êÇ=VMKN=J=OMMTF
cK OMMS=kcm^=NMN=iáÑÉ=p~ÑÉíó=`çÇÉ=Eip`F
dK OMMU=kcm^=TM=k~íáçå~ä=bäÉÅíêáÅ~ä=`çÇÉ
eK OMNM=^a^=pí~åÇ~êÇë=Ñçê=^ÅÅÉëëáÄäÉ=aÉëáÖå
`áíó=J
^K OMMS=fåíÉêå~íáçå~ä=_ìáäÇáåÖ=`çÇÉ
_K OMMS=fåíÉêå~íáçå~ä=mäìãÄáåÖ=`çÇÉ
`K OMMS=fåíÉêå~íáçå~ä=cáêÉ=`çÇÉ
aK= OMMS=fåíÉêå~íáçå~ä=båÉêÖó=`çåëÉêî~íáçå=`çÇÉ
bK OMMU=kcm^=TM=k~íáçå~ä=bäÉÅíêáÅ~ä=`çÇÉ
cK OMMO=k`=^ÅÅÉëëáÄáäáíó=`çÇÉ=ïáíÜ=OMMQ=~ãÉåÇãÉåíë
klqbW=içÅ~ä=~ãÉåÇãÉåíë=~î~áä~ÄäÉ=~í=Åáíó=ïÉÄ=ëáíÉK
ffK lÅÅìé~åÅó=qóéÉëW
^K=dêçìé=_J_ìëáåÉëë=Ef_`=PMQKNF=~åÇ=dêçìé=^JP=^ëëÉãÄäó=Ef_`=
PMPKNF
_K _ìëáåÉëë=Eip`=`ÜK=PUF=~åÇ=^ëëÉãÄäó=Eip`=`ÜK=NOF
fffK `çåëíêìÅíáçå=qóéÉëW
^K qóéÉ=ff=_=Ef_`=SMOKOF
_K qóéÉ=ff=EMMMF=kcm^=OOM
fsK píêìÅíìê~ä=cáêÉ=o~íáåÖëW
kçåÉ=êÉèìáêÉÇK
sK cáêÉ=pìééêÉëëáçå=póëíÉãW
kçåÉ=éêçîáÇÉÇK
sfK eÉáÖÜí=~åÇ=^êÉ~W
låÉJëíçêóX=NNIURM=ëèK=ÑíK=éäìë=OISST=ëèK=ÑíK=EÑìíìêÉ=Éñé~åëáçåF
sffK= líÜÉê=iáÑÉ=p~ÑÉíó=`çåëáÇÉê~íáçåë=Ef_`=êÉÑÉêÉåÅÉÇ=ïÜÉå=êÉèìáêÉãÉåíë=
íÜÉ=ë~ãÉFW
^K lÅÅìé~åí=äç~Ç=Ef_`=NMMQKNKNFW
`ä~ëëêççãë=J
PIMOU=ëèK=ÑíK
=====OM=ëèK=ÑíKLçÅÅK Z NRN=çÅÅìé~åíë
i~Äë=J
NIOUT=ëèK=ÑíK
=====RM=ëèK=ÑíKLçÅÅK Z ==OR=çÅÅìé~åíë
lÑÑáÅÉ=J
TIRPR=ëèK=ÑíK
===NMM=ëèK=ÑíKLçÅÅK Z ==TR=çÅÅìé~åíë
qçí~äW ORN=çÅÅìé~åíë
_K bñáí=Å~é~Åáíó=Ef_`=NMMRKNFW
lìíëáÇÉ=Çççêë=J
P=EPPÒF= Z VVÒ
VVÒ
MKOÒLçÅÅK Z QVR=çÅÅìé~åíë
`K `çêêáÇçê=ïáÇíÜ=Ef_`=NMNTKOFW
QQÒ=ãáåáãìã
aK aÉ~Ç=ÉåÇ=Ef_`=NMNTKPFW
OMÛ=ã~ñáãìã
bK qê~îÉä=Çáëí~åÅÉ=Ef_`=NMNSKNFW
^åó=éçáåí=íç=~å=ÉñáíKKKKKKKKKKKKKKKKKKKKKKKK OMMÛ=ã~ñáãìã
cK aççê=ïáÇíÜ=Ef_`=NMMUKNKNFW
POÒ=ÅäÉ~ê=ïáÇíÜ=ãáåáãìãX=~Åíì~ä=Ä~ëÉÇ=çå=êÉèìáêÉÇ=
Å~é~Åáíó
dK fåíÉêáçê=ÑáåáëÜ=Ef_`=q~ÄäÉ=UMPKRFW
bñáí=ÉåÅäçëìêÉëKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK `ä~ëë=^=ã~ñáãìã
Ñä~ãÉ=
ëéêÉ~Ç
`çêêáÇçêë=KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK̀ ä~ëë=_=ã~ñáãìã=
Ñä~ãÉ
ëéêÉ~Ç
oççãëKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK `ä~ëë=`=ã~ñáãìã
Ñä~ãÉ=
ëéêÉ~Ç
eK `çêêáÇçê=ÅçåëíêìÅíáçå=Ef_`=NMNTKNFW
NJÜçìê=ÑáêÉ=é~êíáíáçå=ÉñíÉåÇÉÇ=íç=ÇÉÅâ=éÉê=f_`=TMU=ïÜÉå=
ëÉêîáåÖ=ãçêÉ=íÜ~å=PM=çÅÅìé~åíë
fK `çêêáÇçê=Çççêë=Ef_`=TNRKQKPFW
OMJãáåìíÉ=ä~ÄÉä=ëãçâÉ=~åÇ=Çê~Ñí=Åçåíêçä=~ëëÉãÄäó=íÉëíÉÇ
éÉê=kcm^=OROI=ri=NM`=~åÇ=ri=NTUQX=ÅäçëáåÖ=ÇÉîáÅÉ=
êÉèìáêÉÇK
gK fåÅáÇÉåí~ä=ìëÉ=~êÉ~ë=ëÉé~ê~íáçå=Ef_`=RMUKO=C=ip`=PUKPKOFW
píçê~ÖÉ=êççãë=çîÉê=NMM=ëèK=ÑíK=KKKKKKKKKKKKKKK= NJÜçìê
píçê~ÖÉ=EëÉîÉêÉ=Ü~ò~êÇFKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK NJÜçìê
hK `çããçå=é~íÜ=çÑ=íê~îÉä=Ef_`=NMNQKPFW
TRÛ=ã~ñáãìã
iK cäççê=ÑáåáëÜ=Ef_`=UMQKQKNFW
MKOO=ï~ííëLëèK=Åã=ãáåáãìã=ÅêáíáÅ~ä=ê~Çá~åí=Ñäìñ=
êÉèìáêÉãÉåíë
jK==^ÅÅÉëëáÄäÉ=ãÉ~åë=çÑ=ÉÖêÉëë=Ef_`=NMMTKN=C=ip`=TKRKQKNFW
mêçîáÇÉÇ=Äó=~í=äÉ~ëí=íïç=êÉãçíÉ=~ÅÅÉëëáÄäÉ=çìíëáÇÉ=ÇççêëK
OUSgLVMMR
UJVJNS
2C05
qóéÉ
k~ãÉ
oççã=å~ãÉNMN
DOOR TAG (3+ NUMBERS)
WINDOW TAG (INTERIORNUMBER, EXTERIOR LETER)
ROOM TAG
SECTION TAG
ENLARGED PLANOR DETAIL TAG
^aaN REVISION TAG
^ KEYNOTE TAG1
A101
pfj
^NMN
Npfj
molmlpba
_rfiafkd=pfqb
tbpq=do^_=`obbh=oa
qkJQS
PROJECT NUMBER
DATE
This drawing shall not be reproduced, published, stored in an electronic retrieval system, or used in any way without written permission of the Architect. Copyright © Johnson Johnson Crabtree Architects P. C.
4551 T
rousdale
Drive
Nashvill
e, T
N 3
7204
tel
fax
615.8
37.0
656
615.8
37.0
657
Joh
nso
n J
ohn
son
Cra
btr
ee A
rch
itec
tsP
.C.
JJC
A
Cumulative Sheet Re-Issue
(Individual revisions cloudedand labeled within sheet)
August 16, 2016
2016
15654.01
August 3, 2016
fJNKNINDEX & CODEANALYSIS
q`^q=aáÅâëçå
aáÅâëçåI=qk
A N
ew
Health
Build
ing F
or:
`lkpqor`qflk=al`rjbkqp=J=p_`=@NSSLMMMJMQJOMNPjN
ARCHITECTURAL FIRE CODE ANALYSISCOVER
fJNKN fkabu=C=`lab=^k^ivpfp
ARCHITECTURAL^MKN ifcb=p^cbqv=mi^k
^NKNJÇ cillo=mi^k=J=afjbkpflkba
^NKNJå cillo=mi^k=J=klqba
^NKQJå ollc=mi^k
^NKOM bki^odba=mi^kp
^NKON mbopmb`qfsb=sfbtp
^OKN _rfiafkd=bibs^qflkp
^OKO _rfiafkd=bibs^qflkp
^OKNM _rfiafkd=pb`qflkp
^PKN pb`qflkp=C=abq^fip
^PKO pb`qflkp=C=abq^fip
^PKON abq^fip
^PKOO abq^fip
^PKOP abq^fip
^QKN abq^fip
^QKO abq^fip
^QKR abq^fip
^QKNN abq^fip
^RKN obcib`qba=`bfifkd=mi^k
^SKN allo=p`ebarib
^SKO tfkalt=bibs^qflkp
^TKN `^pbtloh=bibs^qflkp
^TKNM `^pbtloh=abq^fip
tNKN t^ii=qvmb=L=klqbp=L=ri
^ppbj_ifbp
tNKO abq^fipLmoflofqv=t^ii
af^do^jp
PLUMBING
MECHANICAL
FINISHES
ELECTRICAL
TYPICAL LEGEND OF TAGS
ALTERNATES
TYPICAL LIST OF ABBREVIATIONSPC PERSONAL COMPUTER
STL. STEEL
F.O. FACE OF
CONC. CONCRETE
CLG. CEILING
O.C. ON CENTER
DIA. DIAMETER
W/ WITH
R.D. ROOF DRAIN
BLKG. BLOCKING
MIN. MINIMUM
MAX. MAXIMUM
ALUM. ALUMINUM
CONT. CONTINUOUS
MTL. METAL
TYP. TYPICAL
INSUL. INSULATION
EXIST. EXISTING
KT KEYBOARD TRAY
CT CURTAIN TRACK
T TEMPERED GLASS
VIF VERIFY IN FIELD
UNO UNLESS NOTEDOTHERWISE
TOS TOP OF STEEL
FOMS FACE OF METAL STUD
GYP. BD. GYP. BD.
EXP. JT. EXPANSION JOINT
SQ. FT. SQUARE FOOT
STRUCT. STRUCTURAL
MECH. MECHANICAL
ELEC. ELECTRICAL
EIFS EXTERIORINSULATION FINISHSYSTEM
DEFS DIRECT APPLIEDEXTERIOR FINISHSYSTEM
CMU CONCRETE MASONRYUNIT
EPDM ELASTOMERICMEMBRANE ROOFING
FEC FIRE EXTINGUISHERCABINET
ACT ACOUSTICAL TILE
F.V. FIELD VERFIY
RWL RAINWATER LEADER 1. THE CONTRACTOR SHALL ASSEMBLE COMPONENTS WITH CAREFUL ATTENTION TOINSTALLATION OF FRAMING, SEALANTS, COMPONENTS SUCH AS WINDOWS, DOORFRAMES, LOUVERS, INSULATION SEALANTS, ETC., AS SHOWN ON THE DRAWINGS ANDAS REQUIRED TO CREATE A COMPLETED PROJECT THAT IS IN COMPLIANCE WITHTHE STATED DESIGN INTENT. FURTHERMORE, THE BUILDING SHALL BE INCOMPLIANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND GOODCONSTRUCTION PRACTICES FOR THIS LOCATION.
2. CONTRACTOR SHALL COORDINATE THE WORK OF THE VARIOUS SUBCONTRACTORSAND MATERIAL SUPPLIERS TO ASSURE THE DESIGN INTENT HAS BEEN ACHIEVED.
3. ALL WALLS SHALL BE BUILT INCORPORATING CONTOL JOINTS AND/OR EXPANSIONJOINTS AS APPROPRIATE TO CONTROL MOVEMENT IN THE WALL DUE TOTEMPERATURE VARIANCE.
4. CONTRACTOR SHALL MAINTAIN ALL WALL RATINGS AS SHOWN ON NEW WORKPLANS AND PROPERLY SEAL ALL PENETRATIONS AS REQUIRED FOR NEW WORK.REFERENCE WALL PRIORITY DIAGRAMS SHEET W1.1 FOR PROPER RATED WALLCONSTRUCTION.
GENERAL NOTES
^ÇÇáíáîÉ=^äíÉêå~íÉ=@NW===mêçîáÇÉ=Åçëí=Ñçê=íÜÉ=~ÇÇáíáçå=çÑ=ÅçåÅêÉíÉ=ëí~áêëI=Ü~åÇê~áäëI=~åÇ
~ëëçÅá~íÉÇ=ëáÇÉï~äâ=~Çà~ÅÉåí=íç=ÉñáëíáåÖ=ÄìáäÇáåÖ=~í=çåÉ=äçÅ~íáçå=EêÉã~áåáåÖ=äçÅ~íáçå=íç
ÄÉ=é~êí=çÑ=Ä~ëÉ=ÄáÇFK===pÉÉ=Åáîáä=Çê~ïáåÖë=Ñçê=~ÇÇáíáçå~ä=áåÑçêã~íáçåK
^ÇÇáíáîÉ=^äíÉêå~íÉ=@OW===mêçîáÇÉ=Åçëí=Ñçê=íÜÉ=~ÇÇáíáçå=çÑ=~=é~êâáåÖ=~êÉ~=ESU=ëé~ÅÉëF=~åÇ
~ÅÅÉëë=ÇêáîÉë=íç=íÜÉ=ïÉëí=çÑ=íÜÉ=Ä~ëÉ=ÄáÇ=é~êâáåÖ=äçí=~ë=ëÜçïå=çå=Åáîáä=Çê~ïáåÖëK
BUILDING ENVELOPEOMMS=fåíÉêå~íáçå~ä=båÉêÖó=`çåëÉêî~íáçå=`çÇÉ
E`äáã~íÉ=wçåÉ=QF
ollcW
oÉèìáêÉÇ=oJs~äìÉW=oJNRÅá
aÉëáÖå=oJs~äìÉW=oJORÅá
t^iiW
oÉèìáêÉÇ=oJs~äìÉ=jÉí~ä=cê~ãÉÇW=oJNP
aÉëáÖå=oJs~äìÉW=oJNV=EH=TKR?ÅáF
pi^_W
oÉèìáêÉÇ=oJs~äìÉW=ko
aÉëáÖå=oJs~äìÉW=oJTKRÅá
rJs^irbW
táåÇçï=~êÉ~=PMB=ã~ñ=çÑ=~ÄçîÉ=Öê~ÇÉ=ï~ää
táåÇçï=rJc~Åíçê=cáñÉÇW=MKRM=E`ìêí~áå=t~ääLpíçêÉÑêçåíFI=MKUR=Ebåíê~åÅÉ=aççêFI=MKRR
E^ää=líÜÉêF
aÉëáÖå=dä~òáåÖ=rJs~äìÉW=MKOV
pli^o=eb^q=d^fk=`lbccf`fbkqW
oÉèìáêÉÇ=táåÇçï=ped`W=MKQM
aÉëáÖå=ped`W=MKOU
SEISMIC INFORMATIONpÉáëãáÅ=rëÉ=dêçìéW=ff
páíÉ=`ä~ëëW=a
aÉëáÖå=péÉÅíê~ä=^ÅÅÉäÉê~íáçå=pÇëW=KPVU
aÉëáÖå=péÉÅíê~ä=^ÅÅÉäÉê~íáçå=pÇNW=KOQR
pÉáëãáÅ=aÉëáÖå=`~íÉÖçêóW=a
cMKN cfkfpe=pbib`qflkp=C=dbkbo^i=klqbp
cNKN cillo=mi^k=J=cfkfpebp
cOKN cillo=mi^k=J=crokfqrob
cPKN cillo=mi^k=J=m^qqbok
jMKM es^`=ibdbkap=^ka=p`ebaribp
jMKN es^`=`lkqolip
jMKO es^`=`lkqolip
jNKN es^`=cfopq=cillo
jNKQ es^`=ollc
jOKN es^`=mfmfkd=cfopq=cillo
jTKM es^`=abq^fip
jTKN es^`=abq^fip
jTKO es^`=abq^fip
mMKM mirj_fkd=ibdbkap=^ka=dbkbo^i=klqbp
mNKM mirj_fkd=rkabodolrka
mNKN mirj_fkd=cfopq=cillo
mNKQ mirj_fkd=ollc
mSKM mirj_fkd=ofpbop
mTKM mirj_fkd=abq^fip
mTKN mirj_fkd=abq^fip
bMKM bib`qof`^i=ibdbkap
bMKN ifdeqfkd=cfuqrob=p`ebarib
bMKO bib`qof`^i=ofpbo=^ka=m^kbi=p`ebaribp
bMKP bnrfmjbkq=`lkkb`qflk=p`ebarib
bNKM bib`qof`^i=pfqb=mi^k
bNKN ifdeqfkd=cfopq=cillo
bNKQ bib`qof`^i=ollc
bOKN mltbo=cfopq=cillo
bPKN pvpqbjp=cfopq=cillo
bTKM bib`qof`^i=abq^fip
CIVILprosbov=pebbq=N
prosbov=pebbq=O
`NMM abjlifqflk=mi^k
`OMM lsbo^ii=pfqb=mi^k
`OMN pfqb=mi^k
`ONM pfqb=abq^fip
`ONN pfqb=abq^fip
`ONO pfqb=abq^fip
`ONP pfqb=abq^fip
`PMM= do^afkd
`PMN ^``bppf_fifqv=_ilt=rm
`PMO _flJmlka=_ilt=rm
`QMM mobJabsbilmba=ao^fk^db=j^m
`QMN mlpqJabsbilmba=ao^fk^db=j^m
`QMO ao^fk^db=mi^k
`QMP t^qbo=nr^ifqv=mi^k
`QNM ao^fk^db=abq^fip
`QNN ao^fk^db=abq^fip
`RMM mobJ`lkpqor`qflk=pqloj=t^qbo
mliirqflk=mobsbkqflk=mi^k
`RMN jfaJ`lkpqor`qflk=pqloj=t^qbo
mliirqflk=mobsbkqflk=mi^k
`RMO mlpqJ`lkpqor`qflk=pqloj=t^qbo
mliirqflk=mobsbkqflk=mi^k
`RNM ptmmm=abq^fip
`RNN ptmmm=abq^fip
`SMM rqfifqv=mi^k
`SNM rqfifqv=abq^fip
STRUCTURALpMKN dbkbo^i=klqbp
pMKO nr^ifqv=^ppro^k`b=mi^k
pNKN clrka^qflk=mi^k
pNKO ollc=co^jfkd=mi^kp
pOKN pb`qflkp=^ka=abq^fip
pPKN pb`qflkp=^ka=abq^fip
iNKM mbofjbqbo=i^kap`^mb=mi^k
iNKN `lroqv^oa=i^kap`^mb=mi^k
iNKO `lroqv^oa=i^vlrq=mi^k
LANDSCAPE
VICINITY MAP
^aaN
^aaN
81616
![Page 20: JJCA - Amazon Simple Storage Service · Project Manual For A New Health Building for TCAT Dickson Dickson, TN JJCA Project #15654.01 SBC # 166/000-04-2013M1 August 3rd, 2016 TFM Number:](https://reader031.fdocuments.us/reader031/viewer/2022020305/5c303a0b09d3f217118b56e5/html5/thumbnails/20.jpg)
dolpp=_rfiafkd=^ob^= Z===NNIURM=pc
OVERALL AREA:
KEY:
2C05
pb`
cfob=^i^oj=mrii
bufq
bufq=ifdeq
cfob=buqfkdrfpebo
pjlhb=abqb`qlo
q^ddba=allop=abklqbp
`lkqoli=allo=tfqe
^``bpp=`lkqoli
c^fi=pb`rob=allo=J=pbb
il`hfkd=^oo^kdjbkq
abm abi^vba=bdobpp=m^kf`
c^^ cfob=^i^oj=^kkrk`f^qlo
m^qe=lc=j^ufjrj
qo^sbi=afpq^k`b
qlq^i=_rfiafkd==Z===ORN=l``rm^kqp
Epbb=`lab=^k^ivpfp=clo=`^i`ri^qflkpK=j^glo=pm^`bp=fkaf`^qba
lk=mi^kKF
OCCUPANCY:
qob^qKOMO
qob^qK
OMP
qob^qK
OMQ
qob^qKOMR
a^oholljONN
^fo=`ljmK
ONO
i^_ONM
SRN=pc
`i^ppolljOMS
ihopK
NMN
`ljjNMP
i^rkaov
NMR
pfjK=i^_NNM
lccf`bNMV
^ _ ` a b d f
N
O
Q
R
S
P
c e
`i^ppolljNNP
OPV=pc
pqlo^dbNNO
lccf`bOMU
US=pc
pqlo^dbOMTlccf`b
NMT
lccf`b
NMU
tlohLsfbtfkd
NMS
TP=pc
pqlo^dbNNN
`i^ppolljNMO
il`hbop
OMN
il__v
MMO
sbkafkdMMQ
g^kMMU
qiqKMMV
qiqKMMTbib`
MMS
jb`eMMR
uJo^v
OMV
sbpqMMN
sbpqMMP
`looK
NMM
e^iiOMM
bdobpp
`^m^`fqvW
OOM
TRD=qo^sbi=afpq^k`b
bdobpp
`^m^`fqvW
OOM
bdobpp
`^m^`fqvW
OOM
bdobpp
`^m^`fqvW
OOM
bdobpp
`^m^`fqvW
OOM
bdobpp
`^m^`fqvW
OOM
bdobpp
`^m^`fqvW
OOM
^pprjba=molmboqv=ifkb
E^iiltp=MJelro=o^qfkd=mbo=f_`=q^_ib=SMOF
^pprjba=molmboqv=ifkb
ql=_b=jfkK=NRD
E^iiltp=MJelro=o^qfkd=mbo=f_`=q^_ib=SMOF
^pprjba=molmboqv=ifkb
ql=_b=jfk=NRD
E^iiltp=MJelro=o^qfkd=mbo=f_`=q^_ib=SMOF
^pprjba=molmboqv=ifkb
ql=_b=j
fk=NRD
E^iiltp=MJelro=o^qfkd=mbo=f_`=q^_ib=SMOF
^pprjba=molmboqv=ifkb
ql=_b=j
fk=NRD
E^iiltp=j^uK=colkq^db=fk`ob^pb=mbo=f_`=RMSKOKNF
j^fkq^fk=jfkK=lc=PMD
E^iiltp=j
^uK=colkq^db=fk`ob^pb=mbo=f_`=RMSKOKNF
j^fkq^fk=j
fkK=lc=PMD
`looK
MNM
NNUOëÑLOMëÑ=Z=RV=çÅÅK
PM=çÅÅK=äç~Ç
NNMNëÑLRMëÑ=Z=OO=çÅÅK
NN=çÅÅK=äç~Ç
NNVUëÑLOMëÑ=Z=SM=çÅÅK
PM=çÅÅK=äç~Ç
PS=çÅÅK=äç~Ç
PT=çÅÅK=äç~Ç
PT=çÅÅK=äç~Ç
NN=çÅÅK=äç~Ç
SRNëÑLOMëÑ=Z=PP=çÅÅK
^aaN
^aaN
klkJo^qba=m^oqfqflk
pvj_li=====================================abp`ofmqflk========================================alloLa^jmbo===============moflofqv
WALL LEGEND
NJelro=cfob=m^oqfqflk
NJelro=cfob=_^oofbo
Efk`fabkq^i=rpbJf_`Le^w^oalrpJip`F
JJJ
OM=jfkI=`ilpboI=p=a^jmbop
mlpfqfsb=i^q`eI=QR=jfkI
`ilpboI=kl=a^jmbop=fc
e^oa=ar`qba
ENpqF
EOkaF
EJF
obcbo=ql=tNKN=C=tNKO=clo=^aafqflk^i=fkclK
fk`Krpb=Z=fk`fabkq^i=rpb
PROJECT NUMBER
DATE
This drawing shall not be reproduced, published, stored in an electronic retrieval system, or used in any way without written permission of the Architect. Copyright © Johnson Johnson Crabtree Architects P. C.
4551 T
rousdale
Drive
Nashvill
e, T
N 3
7204
tel
fax
615.8
37.0
656
615.8
37.0
657
Joh
nso
n J
ohn
son
Cra
btr
ee A
rch
itec
tsP
.C.
JJC
A
Cumulative Sheet Re-Issue
(Individual revisions cloudedand labeled within sheet)
August 16, 2016
2016
15654.01
August 3, 2016
^MKNLIFE SAFETY PLAN
q`^q=aáÅâëçå
aáÅâëçåI=qk
A N
ew
Health
Build
ing F
or:
`lkpqor`qflk=al`rjbkqp=J=p_`=@NSSLMMMJMQJOMNPjN
UDMUD
LIFE SAFETY PLAN
81616
![Page 21: JJCA - Amazon Simple Storage Service · Project Manual For A New Health Building for TCAT Dickson Dickson, TN JJCA Project #15654.01 SBC # 166/000-04-2013M1 August 3rd, 2016 TFM Number:](https://reader031.fdocuments.us/reader031/viewer/2022020305/5c303a0b09d3f217118b56e5/html5/thumbnails/21.jpg)
FIRST FLOOR0' - 0"
Level 210' - 0"
e
PD=J=N?PD=J=N?
PD=J=O?
QD=J=NM?
SD=J=Q?
iÉîÉä=N
MD=J=M?
iÉîÉä=O
NMD=J=M?
e
SD=J=M?
PD=J=Q?
OD=J=M?
ND=J=NM?
SD=J=O?
ND=J=NM?
PD=J=O?
UD=J=M?
PD=J=M?
q
q
SD=J=Q?
NMD=J=M?
q
ND=J=NM=NLO?
SD=J=N=PLQ?
ND=J=NM?
OD=J=M? OD=J=NN? OD=J=NN? OD=J=M?
NMD=J=M?
NMD=J=M?
q q q q
SD=J=O?
ND=J=NM?
PD=J=NN? PD=J=NN?
UD=J=M?
NMD=J=M?
ND=J=NM?
a
PD=J=O? OD=J=U? OD=J=U?
ND=J=NM?
SD=J=O?
ND=J=NM?
NMD=J=M?
q
q
UD=J=U?
q
ND=J=NM?
SD=J=O?
ND=J=NM?
OD=J=M?
q
NMD=J=M?
q q
ND=J=M? PD=J=M? PD=J=M? ND=J=Q?
UD=J=Q?
q
RD=J=M? OD=J=V=NLO? QD=J=U=NLO?
NMD=J=M?
q q q
NOD=J=U?
PD=J=O? QD=J=Q=NLO?
ND=J=NM?
SD=J=O?
ND=J=NM?
q
q
TD=J=U=NLO?
q
ND=J=S? PD=J=Q=NLO?
ND=J=NN?
SD=J=N?
MD=J=NM?
VD=J=M?
q
q
FIRST FLOOR0' - 0"
Level 210' - 0"
PD=J=O?
QD=J=M?
SD=J=M?
iÉîÉä=NMD=J=M?
iÉîÉä=ONMD=J=M?
OMD=J=V=NLO?
bn
bn
bn
OD=J=N=NLO?SD=J=V=NLO?OD=J=V=NLO?TD=J=M=NLO?ND=J=NM=NLO?
PSD=J=V=NLO?
bn
bn
bn
PD=J=Q=NLO?UD=J=NN?OD=J=V=NLO?UD=J=P=NLO?OD=J=V=NLO?UD=J=P=NLO?OD=J=N=NLO?
MD=J=NM? PD=J=O? PD=J=M? MD=J=NM?
UD=J=M?
OD=J=V=NLO?
TD=J=M=NLO?
NMD=J=M?
q qq
q
ND=J=NM?
SD=J=O?
ND=J=NM?
QD=J=Q=NLO?PD=J=O?
TD=J=U=NLO?
NMD=J=M?
q
q
q
OD=J=M?
OD=J=M?
OD=J=M?
OD=J=M?
ND=J=NM?
NMD=J=M?
QD=J=NM=NLO? TD=J=T=NLO?
NOD=J=U?
QD=J=M?
PD=J=O?
SD=J=M?
PROJECT NUMBER
DATE
This drawing shall not be reproduced, published, stored in an electronic retrieval system, or used in any way without written permission of the Architect. Copyright © Johnson Johnson Crabtree Architects P. C.
4551 T
rousdale
Drive
Nashvill
e, T
N 3
7204
tel
fax
615.8
37.0
656
615.8
37.0
657
Joh
nso
n J
ohn
son
Cra
btr
ee A
rch
itec
tsP
.C.
JJC
A
Cumulative Sheet Re-Issue
(Individual revisions cloudedand labeled within sheet)
August 16, 2016
2016
15654.01
August 3, 2016
^SKOWINDOWELEVATIONS
q`^q=aáÅâëçå
aáÅâëçåI=qk
A N
ew
Health
Build
ing F
or:
`lkpqor`qflk=al`rjbkqp=J=p_`=@NSSLMMMJMQJOMNPjN
^_`abcdefg
=buqboflo=pqlobcolkq=tfkalt=bibs^qflkp
fkqboflo=pqlobcolkq=^ka=eliilt=jbq^i=tfkalt=bibs^qflkp
ODQD M QD
ODQD M QD
O N
^irjfkrj=pqlobcolkq ^irjfkrj=pqlobcolkq ^irjfkrj=pqlobcolkq ^irjfkrj=pqlobcolkq ^irjfkrj=pqlobcolkq ^irjfkrj=pqlobcolkq ^irjfkrj=pqlobcolkq ^irjfkrj=pqlobcolkq ^irjfkrj=pqlobcolkq ^irjfkrj=pqlobcolkq
fkqboflo=^irjfkrj=eliilt=jbq^i fkqboflo=^irjfkrj=eliilt=jbq^i
hi
O=il`^qflkpW=@OMM=C=@OMM^=EjfoolobaF
pbb=_rfiafkd=bibs^qflkp=clo
il`^qflk
pbb=_rfiafkd=bibs^qflkp=clo
il`^qflk
P
fkqboflo=^irjfkrj=pqlobcolkq
Q
fkqboflo=^irjfkrj=pqlobcolkq
j
^irjfkrj=pqlobcolkq
R
fkqboflo=^irjfkrj=eliilt=jbq^i
^q=il`^qflkp=fkaf`^qba=ql
_b=o^qbaI=molsfab=SM=jfk
o^qfkd=^q=tfkalt=^ka=^q
alloK
^q=il`^qflkp=fkaf`^qba=ql
_b=o^qbaI=molsfab=SM=jfk
o^qfkd=^q=tfkaltK
^aaN ^aaN
81616
![Page 22: JJCA - Amazon Simple Storage Service · Project Manual For A New Health Building for TCAT Dickson Dickson, TN JJCA Project #15654.01 SBC # 166/000-04-2013M1 August 3rd, 2016 TFM Number:](https://reader031.fdocuments.us/reader031/viewer/2022020305/5c303a0b09d3f217118b56e5/html5/thumbnails/22.jpg)
BUILDING LIGHTING FIXTURE SCHEDULETYPE MANUFACTURER
SERIES NUMBER(BASIS OF DESIGN) VOLTAGE LAMPS
MAX INPUTWATTAGE MOUNTING DESCRIPTION
A2 LITHONIA 2VT8 120 / 277 (2) - 32W T8 60 RECESSED GRID 2X4 VOLUMETRIC TROFFER, ACRYLIC PRISMATIC DIFFUSER, (1) 2-LAMPBALLASTS.
A2E LITHONIA 2VT8 120 / 277 (2) - 32W T8 60 RECESSED GRID 2X4 VOLUMETRIC TROFFER, ACRYLIC PRISMATIC DIFFUSER, (1) 2-LAMPBALLASTS, 1400 LUMEN EMERGENCY BATTERY PACK.
A2FE LITHONIA 2VT8 120 / 277 (2) - 32W T8 60 RECESSED FLANGE2X4 VOLUMETRIC TROFFER, ACRYLIC PRISMATIC DIFFUSER, (1) 2-LAMPBALLASTS, DRYWALL CEILING ADAPTER, 1400 LUMEN EMERGENCY BATTERYPACK.
A3 LITHONIA 2VT8 120 / 277 (3) - 32W T8 85 RECESSED GRID 2X4 VOLUMETRIC TROFFER, ACRYLIC PRISMATIC DIFFUSER, (1) 2-LAMP AND (1)1-LAMP BALLAST CONFIGURATION.
A3E LITHONIA 2VT8 120 / 277 (3) - 32W T8 85 RECESSED GRID 2X4 VOLUMETRIC TROFFER, ACRYLIC PRISMATIC DIFFUSER, (1) 2-LAMP AND (1)1-LAMP BALLAST CONFIGURATION, 1400 LUMEN EMERGENCY BATTERY PACK.
B21 LITHONIA 2SP 120 / 277 (2) - 32W T8 60 RECESSED GRID 2X4 LENSED TROFFER, WHITE FLUSH STEEL DOOR, #12 PATTERN 0.125"ACRYLIC LENS, (1) 2-LAMP BALLAST.
B22 LITHONIA 2SP 120 / 277 (2) - 32W T8 60 RECESSED GRID 2X4 LENSED TROFFER, WHITE FLUSH STEEL DOOR, #12 PATTERN 0.125"ACRYLIC LENS, (2) 1-LAMP BALLASTS.
B3 LITHONIA 2SP 120 / 277 (3) - 32W T8 85 RECESSED GRID 2X4 LENSED TROFFER, WHITE FLUSH STEEL DOOR, #12 PATTERN 0.125"ACRYLIC LENS, (1) 2-LAMP AND (1) 1-LAMP BALLAST CONFIGURATION.
C1 PEERLESS CRW7 120 (1) - 32W T8 34 SURFACESEE ARCH. ELEV.
4' INDIRECT WITH PERFORATED LOWER HOUSING, 1-LAMP, WHITE REFLECTOR,PAINTED ALUMINUM FINISH, DUST COVER.
C1E PEERLESS CRW7 120 (1) - 32W T8 34 SURFACESEE ARCH. ELEV.
4' INDIRECT WITH PERFORATED LOWER HOUSING, 1-LAMP, WHITE REFLECTOR,PAINTED ALUMINUM FINISH, DUST COVER, 1400 LUMEN EMERGENCY BATTERYPACK.
C2 PEERLESS CRW4 120 (1) - 32W T8 34 SURFACESEE ARCH. ELEV.
4' INDIRECT WITH PERFORATED AND LOUVERED LOWER HOUSING, 1-LAMP,WHITE REFLECTOR, PAINTED ALUMINUM FINISH, DUST COVER.
D1 GOTHAM EVO 120 / 277 LED 19 RECESSED FLANGE 6" DOWNLIGHT, 1500 LUMENS, CLEAR APERTURE/TRIM COLOR, SELF-FLANGED,WIDE DISTRIBUTION, SPECULAR FINISH.
D1E GOTHAM EVO 120 / 277 LED 19 RECESSED FLANGE6" DOWNLIGHT, 1500 LUMENS, CLEAR APERTURE/TRIM COLOR, SELF-FLANGED,WIDE DISTRIBUTION, SPECULAR FINISH, EMERGENCY BATTERY PACK WITHINTEGRAL TEST SWITCH.
D2 GOTHAM EVO 120 / 277 LED 37 RECESSED FLANGE 6" DOWNLIGHT, 3000 LUMENS, CLEAR APERTURE/TRIM COLOR, SELF-FLANGED,MEDIUM DISTRIBUTION, SPECULAR FINISH.
D3 GOTHAM EVO 120 / 277 LED 12 RECESSED FLANGE 6" DOWNLIGHT, 1000 LUMENS, CLEAR APERTURE/TRIM COLOR, SELF-FLANGED,MEDIUM DISTRIBUTION, SPECULAR FINISH.
D3E GOTHAM EVO 120 / 277 LED 12 RECESSED FLANGE6" DOWNLIGHT, 1000 LUMENS, CLEAR APERTURE/TRIM COLOR, SELF-FLANGED,WIDE DISTRIBUTION, SPECULAR FINISH, EMERGENCY BATTERY PACK WITHINTEGRAL TEST SWITCH.
F LITHONIA C 120 / 277 (2) - 32W T8 60 SUSPENDED+10' AFF 4' STRIP, (1) 2-LAMP BALLAST, WIRE GUARD, CHAIN HANGER.
G2 KENALL AUCLED 120 LED 13 SURFACE 2' UNDER CABINET, SOLID FRONT, MATTE WHITE FINISH, 700 LUMENS.
G4 KENALL AUCLED 120 LED 23 SURFACE 4' UNDER CABINET, SOLID FRONT, MATTE WHITE FINISH, 1300 LUMENS.
T1 LITHONIA TWF 120 / 277 (2) - 26W TRT 52 SURFACESEE ARCH. ELEV.
EXTERIOR WALL SCONCE, (2) ONE-LAMP ELECTRONIC BALLASTS, COLDWEATHER EMERGENCY BATTERY PACK, DARK BRONZE TEXTURED FINISH.
X1 LITHONIA LE 120 / 277 LED 5 UNIVERSAL SINGLE-FACE EXIT SIGN, GREEN LETTER, WHITE HOUSING, BATTERY BACK-UP.
X2 LITHONIA LE 120 / 277 LED 5 UNIVERSAL DUAL-FACE EXIT SIGN, GREEN LETTER, WHITE HOUSING, BATTERY BACKUP.
X4 LITHONIA ELM2 LED 120 / 277 LED 5 UNIVERSAL DUAL-HEAD EMERGENCY LIGHT, WHITE HOUSING.
GENERAL NOTES (BUILDING INTERIOR LIGHTING FIXTURE SCHEDULE ONLY):
A. SERIES NUMBERS LISTED ARE BY THE BASIS OF DESIGN MANUFACTURER. OTHER ACCEPTABLE MANUFACTURES ARE LISTED IN THE ELECTRICAL SPECIFICATIONS.
B. FURNISH AND INSTALL ALL LINEAR FLUORESCENT (T8, T5, T5HO) FIXTURES WITH 3500K, 80+ CRI, LAMPS AND SOLID-STATE ELECTRONIC PROGRAMMED RAPID START BALLASTS, UNLESS OTHERWISE NOTED ON THIS SCHEDULE.
C. ALL LED EQUIPPED FIXTURES SHALL UTILIZE 3500K SOURCES AND SHALL INCLUDE 0-10V DIMMING, MINIMUM DIMMING LEVEL 10%, UNLESS OTHERWISE NOTED ON THIS SCHEDULE. COORDINATE DIMMING REQUIREMENTS WITH FIXTURE AND CONTROL MANUFACTURERS PRIOR TO ORDERING.
D. CONTRACTOR SHALL VERIFY CEILING TYPE AND MOUNTING REQUIREMENTS PRIOR TO INSTALLATION.
LIGHTING CONTROLS DEVICE SCHEDULESYMBOL MANUFACTURER SERIES NUMBER DESCRIPTION
LUTRON DVSTV WALL DIMMER, 0-10V
LUTRON MAF DIGITAL DIMMER, PROVIDES TRUE THREE-WAY DIMMING
HUBBELL BUILDINGAUTOMATION LHIRS1 WALL SWITCH, PIR, AUTO ON / MANUAL ON OPERATING MODES
HUBBELL BUILDINGAUTOMATION LHDIRS3 WALL SWITCH, PIR, AUTO ON / MANUAL ON OPERATING MODES,
BUILT-IN PHOTOCELL FOR DAYLIGHT HARVESTING CONTROL.
HUBBELL BUILDINGAUTOMATION ONMIDT2000 CEILING MOUNTED, ULTRASONIC AND INFRARED, 2000 SQ. FT.
HUBBELL BUILDINGAUTOMATION LUXSTATSW2AUTO DIGITAL SWITCH, 2-BUTTON
HUBBELL BUILDINGAUTOMATION LUXSTATSW4 DIGITAL SWITCH, 4-BUTTON
HUBBELL BUILDINGAUTOMATION LUXSTATOCM
DAYLIGHT HARVESTING CONTROLLER, UP TO 3 ZONES, ON/OFFCONTROL, INDIVIDUAL ADJUSTMENT OF 3 ZONES, INTEGRATIONWITH OCC. SENSORS AND MANUAL OVERRIDE CONTROLS.
NOTES:1. LISTED MANUFACTURER IS BASIS OF DESIGN; SERIES NUMBER IS BY THE BASIS OF DESIGN MANUFACTURER. OTHER ACCEPTABLE MANUFACTURERS ARE LISTED IN THE ELECTRICAL SPECIFICATIONS.2. ALL SENSOR LOCATIONS ARE APPROXIMATE. REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS PRIOR TO INSTALLATION.3. ULTRASONIC CEILING MOUNTED SENSORS SHOULD BE LOCATED A MINIMUM OF SIX (6) FEET FROM HVAC SUPPLY/RETURN VENTS.4. CONTRACTOR IS RESPONSIBLE FOR PROPER SENSITIVITY AND TIME DELAY SETTINGS, FOR NON-ADAPTIVE PRODUCTS, FOLLOWING THE MANUFACTURER'S RECOMMENDED PLACEMENT, AND FIELD VERIFICATION OF CIRCUITS WITH RESPECT TO POWER PACK PLACEMENT.5. POWER PACKS (HUBBELL BUILDING AUTOMATION #UVPP) ARE REQUIRED FOR CEILING MOUNTED OCCUPANCY SENSORS.6. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF REQUIRED NUMBER OF POWER PACKS: -ONE POWER PACK IS REQUIRED FOR EACH CONTROLLED CIRCUIT. -SEVERAL SENSORS AND ADD-A-RELAYS CAN BE WIRED IN PARALLEL TO A SINGLE POWER PACK, NOT TO EXCEED 150mA TOTAL POWER CONSUMPTION. -IF MULTIPLE CIRCUITS ARE TO TO BE CONTROLLED BY A SINGLE SENSOR, AUXILIARY RELAYS MAY BE USED IN CONJUNCTION WITH A POWER PACK.7. SENSORS MOUNTED OVER DOORWAYS SHOULD BE PLACED ONE (1) FOOT INSIDE THRESHOLD.8. POWER PACK (HUBBELL BUILDING AUTOMATION #LUXSTATPP) IS REQUIRED FOR DAYLIGHT HARVESTING CONTROLLER.
SD
OC
SM
DS-1
DS-2
SD3
SM2
DHC
PROJECT NUMBER
DATE
This drawing shall not be reproduced, published, stored in an electronic retrieval system, or used in any way without written permission of the Architect. Copyright © Johnson Johnson Crabtree Architects P. C.
4551
Tro
usda
le D
rive
Nas
hville
, TN
372
04te
lfa
x61
5.83
7.06
5661
5.83
7.06
57Jo
hnso
n Jo
hnso
nC
rabt
ree
Arc
hite
cts
P.C
.
JJC
A
Cumulative Sheet Re-Issue
(Individual revisions cloudedand labeled within sheet)
4633 Trousdale DriveNashville, TN 37204Phone: 615.661.6211Env Project #15104.00
August 16, 2016
2016
15654.01
August 3, 2016
E0.1Lighting FixtureSchedule
TC
AT D
icks
onD
icks
on, T
N
A Ne
w He
alth
Bui
ldin
g Fo
r:
CONSTRUCTION DOCUMENTS - SBC #166/000-04-2013M1
1
![Page 23: JJCA - Amazon Simple Storage Service · Project Manual For A New Health Building for TCAT Dickson Dickson, TN JJCA Project #15654.01 SBC # 166/000-04-2013M1 August 3rd, 2016 TFM Number:](https://reader031.fdocuments.us/reader031/viewer/2022020305/5c303a0b09d3f217118b56e5/html5/thumbnails/23.jpg)
COPPER FEEDER SCHEDULE
NUMBER CONDUCTORS THW COPPER CONDUIT
CONDUITWITHOUTNEUTRAL
FEEDERAMPACITY
1 4#12, 1#12G 3/4" 1/2" 25 A
2 2#10, 1#10G 1/2" N/A 35 A
3 4#10, 1#10G 3/4" 1/2" 35 A
4 4#8, 1#10G 1" 1" 50 A
5 4#6, 1#8G 1-1/4" 1" 65 A
6 4#4, 1#8G 1-1/4" 1-1/4" 85 A
7 4#3, 1#8G 1-1/4" 1-1/4" 100 A
8 4#2, 1#6G 1-1/2" 1-1/4" 115 A
9 4#1, 1#6G 2" 1-1/2" 130 A
10 4#1/0, 1#6G 2" 1-1/2" 150 A
11 4#2/0, 1#6G 2" 2" 175 A
12 4#3/0, 1#6G 2-1/2" 2" 200 A
13 4#4/0, 1#4G 2-1/2" 2" 230 A
14 4#250MCM, 1#4G 3" 2-1/2" 255 A
15 4#300MCM, 1#4G 3" 2-1/2" 285 A
16 4#350MCM, 1#3G 3" 3" 310 A
17 4#400MCM, 1#3G 3" 3" 335 A
18 4#500MCM, 1#3G 3−1/2" 3" 380 A
19 4#600MCM, 1#2G 4" 3-1/2" 420 A
20 4#750MCM, 1#2G 4" 3-1/2" 475 A
21 (2 SETS) 4#4/0, 1#2G 2-1/2" EA 2" EA 460 A
22 (2 SETS) 4#250MCM, 1#2G 3" EA 2-1/2" EA 510 A
23 (2 SETS) 4#350MCM, 1#1G 3" EA 3" EA 620 A
24 (2 SETS) 4#500MCM, 1#1/0G 3-1/2" EA 3" EA 760 A
25 (2 SETS) 4#600MCM, 1#2/0G 4" EA 3-1/2" EA 840 A
26 (3 SETS) 4#350MCM, 1#2/0G 3" EA 3" EA 930 A
27 (3 SETS) 4#400MCM, 1#2/0G 3-1/2" EA 3" EA 1005 A
28 (3 SETS) 4#750MCM, 1#3/0G 5" EA 4" EA 1425 A
29 (4 SETS) 4#600MCM, 1#4/0G 4" EA 3−1/2" EA 1680 A
NOTES:
1. WHERE FEEDER SIZE IS SHOWN WITH A SUBSCRIPT "N", THE NEUTRAL CONDUCTOR SHALL BE DELETED FROM THE CONDUCTORS SHOWN IN THE FEEDER SCHEDULE.
BRANCH CIRCUIT VOLTAGE DROP CHART277 VOLT CIRCUITS 120 VOLT CIRCUITS
CONDUCTORSIZE
MAXIMUM BRANCH CIRCUITLENGTH
CONDUCTORSIZE
MAXIMUM BRANCH CIRCUITLENGTH
#12 180 FEET #12 80 FEET
#10 290 FEET #10 125 FEET
#8 460 FEET #8 200FEET
#6 720 FEET #6 310 FEET
NOTES:
1. BRANCH CIRCUIT CONDUCTOR SHALL BE SIZED PER "BRANCH CIRCUIT VOLTAGE DROP CHART" UNLESS OTHERWISE NOTED.2. MAXIMUM BRACH CIRCUIT LENGTH IS BASED ON A 16 AMP LOAD WITH A MAXIMUM ALLOWABLE VOLTAGE DROP OF 4%.
PANEL: MDP OC DEVICE TYPE: Breaker ENCLOSURE: NEMA 1 MAINS(A): 600A MCB CONTINUOUS(A): 600 LOCATION: ELECTRICAL ROOM DEVICE FAMILY: Bolt On MOUNTING: Surface WIRING: 3-Phase 4-Wire BUS SC RATING(A) 35000 FED FROM: BUS-UTIL VOLTAGE: 208/120 FAULT CURRENT(A): 16083 *MAIN BREAKER SHALL BE 100% RATED.
CUBICLE CONNECTED DEMAND DESIGN DESIGN OC DEVICE NO DESCRIPTION kVA kVA kVA MAX AMPS TYPE SIZE P NOTES
1 RTU-1 103.40 102.72 102.72 285.11 350 3 2 HWP-1 1.33 1.13 1.13 3.15 15 3 3 HWP-2 1.33 1.13 1.13 3.15 15 3 4 HWP-3 2.81 2.39 2.39 6.63 15 3 5 HWP-4 2.81 2.39 2.39 6.63 15 3 6 BUS-L1 60.75 48.96 53.27 160.12 250 3 100% RATED 7 BUS-L3 53.25 37.92 37.92 116.34 200 3 100% RATED 8 SPACE 0.00 0.00 0.00 0.00 0 3 9 SPACE 0.00 0.00 0.00 0.00 0 3 10 SPD-SE 0.00 0.00 0.00 0.00 30 3
ALL CONNECTED KVA MAX PH AMPS * PHASE TOTALS VA AMPS BUS TOTALS KVA TOTAL CONNECTED 225.59 626.2 * A-N 75197.2 626.2 CONNECTED 225.59 TOTAL DEMAND 176.37 489.5 * B-N 75197.2 626.2 DEMAND 176.37 TOTAL DESIGN 180.67 501.5 * C-N 75197.2 626.2 DESIGN 180.67
PANEL: L1 OC DEVICE TYPE: Breaker ENCLOSURE: NEMA 1 MAINS(A): MLO CONTINUOUS(A): 250 LOCATION: ELECTRICAL ROOM DEVICE FAMILY: Bolt On MOUNTING: Surface WIRING: 3-Phase 4-Wire BUS SC RATING(A) 35000 FED FROM: BUS- MDP VOLTAGE: 208/120 FAULT CURRENT(A): 15288 *PANEL SHALL HAVE FEED-THRU LUGS
OC NOTES DESCRIPTION DEMAND VA CKT PHASE LOADS VA CKT VA DEMAND DESCRIPTION NOTES OC AMPS P CODE A B C CODE AMPS P
20 1 GFCI TLT SENSORS & EWC EQP 1300 1 2245 2 948 LTS CORR EGRESS LTS 20 1 20 1 TLT/ELEC/JC REC REC 1260 3 2090 4 830 LTS MECH/ELEC/TLT LTS 20 1 20 1 MECH RM REC REC 360 5 1452 6 1092 LTS LOBBY LTS 20 1 20 1 GFCI VENDING MACHINE REC 1201 7 2698 8 1497 LTS CLASSRM/OFFICE LTS 20 1 20 1 GFCI VENDING MACHINE REC 1201 9 2471 10 1270 LTS SIM LAB/STORAGE LTS 20 1 20 1 VENDING REF REC 780 11 1747 12 967 LTS CLASSROOM LTS 20 1 20 1 VENDING REF REC 780 13 1475 14 695 LTS CORR LTS 20 1 20 1 VENDING COUNTER REC REC 1575 15 2153 16 578 LTS TREATMENT RMS LTS 20 1 20 1 VENDING COUNTER REC REC 1575 17 2767 18 1192 LTS CLASSRM/OFF/LAB LTS 20 1 20 1 VENDING COUNTER REC REC 1575 19 2016 20 441 LTS EXTERIOR BLDG LTS 20 1 20 1 VENDING COUNTER REC REC 180 21 1680 22 1500 LTS BLDG SIGN - NORTH 20 1 20 1 VENDING COUNTER REC REC 180 23 1680 24 1500 LTS BLDG SIGN - NORTH 20 1 20 1 VENDING MICROWAVE REC 1656 25 3156 26 1500 LTS BLDG SIGN - EAST 20 1 20 1 VENDING MICROWAVE REC 1656 27 2254 28 600 EQP FIRE/SMOKE DMPR XFMR 20 1 20 1 VENDING MICROWAVE REC 1656 29 2254 30 600 EQP FIRE/SMOKE DMPR XFMR 20 1 20 1 LOBBY REC REC 1440 31 2038 32 600 EQP FIRE/SMOKE DMPR XFMR 20 1 20 1 LOBBY REC REC 720 33 1318 34 600 EQP TEMP CTRL PANEL 20 1 20 1 LOCKERS/CORR REC REC 540 35 1470 36 1860 LTS PARKING LTS 20 2 30 3 SPD-BP EQP 0 37 930 38 - "" "" "" "" - 39 698 40 1395 LTS PARKING LTS 20 2 "" "" - 41 698 42 - "" ""
ALL CONNECTED KVA MAX PH AMPS * PHASE TOTALS VA AMPS BUS TOTALS KVA TOTAL CONNECTED 39.28 121.2 * A-N 14554.1 121.2 CONNECTED 60.75 TOTAL DEMAND 33.64 101.1 * B-N 12661.7 105.4 DEMAND 48.96 TOTAL DESIGN 37.96 113.6 * C-N 12066.4 100.5 DESIGN 53.27
PANEL: L2 OC DEVICE TYPE: Breaker ENCLOSURE: NEMA 1 MAINS(A): MLO CONTINUOUS(A): 250 LOCATION: ELECTRICAL ROOM DEVICE FAMILY: Bolt On MOUNTING: Surface WIRING: 3-Phase 4-Wire BUS SC RATING(A) 35000 FED FROM: BUS-L1 VOLTAGE: 208/120 FAULT CURRENT(A): 15179
OC NOTES DESCRIPTION DEMAND VA CKT PHASE LOADS VA CKT VA DEMAND DESCRIPTION NOTES OC AMPS P CODE A B C CODE AMPS P
20 1 B-1 EQP 200 1 1400 2 1200 MED EQP TREAT. X-RAY 20 1 20 1 B-2 EQP 200 3 1400 4 1200 MED EQP TREAT. CHAIR GFCI 20 1 20 1 EF-1 MOTORS 697 5 1897 6 1200 MED EQP TREAT. X-RAY 20 1 20 1 EF-2 MOTORS 697 7 1897 8 1200 MED EQP TREAT. CHAIR GFCI 20 1 20 1 WH-1 EQP 200 9 1400 10 1200 MED EQP TREAT. X-RAY 20 1 20 1 PP-1 EQP 200 11 1400 12 1200 MED EQP TREAT. CHAIR GFCI 20 1 20 1 LCP EQP 600 13 1800 14 1200 MED EQP TREAT. X-RAY 20 1 20 1 LOCK-ON FACP EQP 600 15 1800 16 1200 MED EQP TREAT. CHAIR GFCI 20 1 20 1 VENDING DISPOSAL MOTORS 1177 17 1894 18 720 REC TREAT. REC 20 1 20 1 GFCI, LOCKOUT CIVIL HOTBOX HEAT 1000 19 1712 20 720 REC TREAT. REC 20 1 25 1 GFCI, LOCKOUT CIVIL HOTBOX HEAT 2000 21 2958 22 961 EQP VAV BOXES 20 1 25 1 GFCI, LOCKOUT CIVIL HOTBOX HEAT 2000 23 2000 24 0 SPARE SPARE 20 1 20 1 SPARE SPARE 0 25 0 26 0 SPARE SPARE 20 1 20 1 SPARE SPARE 0 27 0 28 0 SPARE SPARE 20 1 20 1 SPARE SPARE 0 29 0 30 0 SPARE SPARE 20 1 20 1 SPARE SPARE 0 31 0 32 0 SPARE SPARE 20 1 20 1 SPARE SPARE 0 33 0 34 0 SPARE SPARE 20 1 20 1 SPARE SPARE 0 35 0 36 0 SPARE SPARE 20 1 20 1 SPARE SPARE 0 37 0 38 0 SPARE SPARE 20 1 20 1 SPARE SPARE 0 39 0 40 0 SPARE SPARE 20 1 20 1 SPARE SPARE 0 41 0 42 0 SPARE SPARE 20 1
ALL CONNECTED KVA MAX PH AMPS * PHASE TOTALS VA AMPS BUS TOTALS KVA TOTAL CONNECTED 21.55 62.9 * A-N 6808.7 56.7 CONNECTED 21.55 TOTAL DEMAND 16.10 47.5 * B-N 7554.9 62.9 DEMAND 16.10 TOTAL DESIGN 16.10 47.5 * C-N 7182.4 59.8 DESIGN 16.10
PANEL: L3 OC DEVICE TYPE: Breaker ENCLOSURE: NEMA 1 MAINS(A): MLO CONTINUOUS(A): 200 LOCATION: STORAGE ROOM DEVICE FAMILY: Bolt On MOUNTING: Surface WIRING: 3-Phase 4-Wire BUS SC RATING(A) 35000 FED FROM: BUS- MDP VOLTAGE: 208/120 FAULT CURRENT(A): 8302
OC NOTES DESCRIPTION DEMAND VA CKT PHASE LOADS VA CKT VA DEMAND DESCRIPTION NOTES OC AMPS P CODE A B C CODE AMPS P
20 1 CLASSRM REC REC 1080 1 1980 2 900 REC CLASSRM REC 20 1 20 1 CLASSRM REC REC 1200 3 2040 4 840 REC CLASSRM REC 20 1 20 1 WORK RM REC REC 540 5 1440 6 900 REC OFFICE/STOR REC 20 1 20 1 OFFICE REC REC 1080 7 1440 8 360 REC ROOFTOP REC 20 1 20 1 OFFICE REC REC 720 9 1894 10 1177 MOTORS EF-3 20 1 20 1 SIM LAB REC REC 1440 11 1543 12 208 MOTORS AH-1 15 2 20 1 SIM LAB REC REC 1440 13 1543 14 - "" "" 20 1 SIM LAB REC REC 1440 15 3515 16 4160 A/C HP-1 30 2 20 1 SIM LAB REC REC 1440 17 3515 18 - "" "" 20 1 LAPTOP CART REC REC 1800 19 3596 20 1801 MOTORS DAC-1 30 1 20 1 LAPTOP CART REC REC 1800 21 3158 22 2725 MOTORS DVP-1 20 2 20 1 CORR/LKRS/STOR REC REC 1080 23 2439 24 - "" "" 20 1 COMM RM REC REC 360 25 1721 26 2725 MOTORS DVP-2 20 2 20 1 COMM RM REC REC 360 27 1721 28 - "" "" 20 1 WASHING MACHINE REC 1200 29 1897 30 697 REC LAB LATHE 20 1 30 2 DRYER HEAT 4784 31 3079 32 697 REC LAB LATHE 20 1 "" "" - 33 3245 34 865 REC LAB TRIMMER 20 1 20 1 CLASSRM REC REC 900 35 1765 36 865 REC LAB TRIMMER 20 1 20 1 CLASSRM REC REC 1020 37 1885 38 865 REC LAB TRIMMER 20 1 20 1 DARK RM REC REC 900 39 1765 40 865 REC LAB TRIMMER 20 1 20 1 X-RAY MED EQP 1921 41 2998 42 1080 REC LAB PLUGMOLD 20 1 20 1 LAB AUTOCLAVE REC 1500 43 2760 44 1260 REC LAB PLUGMOLD 20 1 20 1 DISHWASHER REC 1092 45 1291 46 200 EQP AIR/VAC CTRL PNL 20 1 20 1 CLASSROOM FLOORBOX REC 360 47 360 48 0 SPARE SPARE 20 1 20 1 CLASSROOM FLOORBOX REC 360 49 360 50 0 SPARE SPARE 20 1 20 1 CLASSROOM FLOORBOX REC 360 51 360 52 0 SPARE SPARE 20 1 20 1 SPARE SPARE 0 53 0 54 0 SPARE SPARE 20 1 20 1 SPARE SPARE 0 55 0 56 0 SPARE SPARE 20 1 20 1 SPARE SPARE 0 57 0 58 0 SPARE SPARE 20 1 20 1 SPARE SPARE 0 59 0 60 0 SPARE SPARE 20 1
ALL CONNECTED KVA MAX PH AMPS * PHASE TOTALS VA AMPS BUS TOTALS KVA TOTAL CONNECTED 53.25 158.0 * A-N 18336.4 152.7 CONNECTED 53.25 TOTAL DEMAND 37.92 116.3 * B-N 18969.3 158.0 DEMAND 37.92 TOTAL DESIGN 37.92 116.3 * C-N 15949.6 132.8 DESIGN 37.92
BUILDINGEXTERIOR
ELECTRICALROOM
TO UTILITY POLE
PADMOUNTED
XFMR
SPD-SE
3
(2 SETS) 4#350MCM, 3"C EA
#2/0 CU GND - 3/4"C
PANELMDP
120/208V600AMCB
PANEL
120/208VL1
250AMLO
PANEL
120/208VL3
200AMLO
PANEL
120/208VL2
250AMLO
14
12
SPD-BP
3
M
FURNISH ANDINSTALL
METER BASE
STORAGEROOM
14
LIGHTINGCONTROL
PANEL(LCP)
PC ROOFMOUNTED
(2) 4"C
PROJECT NUMBER
DATE
This drawing shall not be reproduced, published, stored in an electronic retrieval system, or used in any way without written permission of the Architect. Copyright © Johnson Johnson Crabtree Architects P. C.
4551
Tro
usda
le D
rive
Nas
hville
, TN
372
04te
lfa
x61
5.83
7.06
5661
5.83
7.06
57Jo
hnso
n Jo
hnso
nC
rabt
ree
Arc
hite
cts
P.C
.
JJC
A
Cumulative Sheet Re-Issue
(Individual revisions cloudedand labeled within sheet)
4633 Trousdale DriveNashville, TN 37204Phone: 615.661.6211Env Project #15104.00
August 16, 2016
2016
15654.01
August 3, 2016
E0.2Electrical Riser andPanel Schedules
TC
AT D
icks
onD
icks
on, T
N
A Ne
w He
alth
Bui
ldin
g Fo
r:
CONSTRUCTION DOCUMENTS - SBC #166/000-04-2013M1
1
![Page 24: JJCA - Amazon Simple Storage Service · Project Manual For A New Health Building for TCAT Dickson Dickson, TN JJCA Project #15654.01 SBC # 166/000-04-2013M1 August 3rd, 2016 TFM Number:](https://reader031.fdocuments.us/reader031/viewer/2022020305/5c303a0b09d3f217118b56e5/html5/thumbnails/24.jpg)
M
M
OC
OC
MMM
M
M
M
MM
M
M
OC
DM
D
M
LV
D
OC
OC
OC
PCPC
OC
33
33
LV
33
3
LV
PC
PC
OC
OC
D
44
3
SIM. LAB110
OFFICE108
LKRS.101
LOCKERS201
CLASSROOM206
COMM103
LAUNDRY105
DARKROOM211
AIR COMP.212
TREAT.203
TREAT.202
X-RAY209
CLASSROOM102
CLASSROOM113
239 SFSTORAGE
112
86 SFSTORAGE
207
105 SFOFFICE
208
WORK/VIEWING106
OFFICE107
OFFICE109
73 SFSTORAGE
111
233 SFMECH
00579 SFELEC006
196 SFTLT.007
62 SFJAN008
194 SFTLT.009
253 SFVENDING
004
REF
PANTOS 16
LAPTOP CART
CV5R
AIRSTAR21
24 HALF-HEIGHTLOCKERS ANDCOAT HOOKS
56 HALF-HEIGHTLOCKERS ANDCOAT HOOKS
VENDINGMACINES
1315 SFLOBBY
002
RESOURCESHELVES
104
VEST001
VEST003
PODIUM
PODIUM
REF
TV
CO
AT
HO
OK
S
DW
STERILIZATION AREA: 30"-DEEPCOUNTERTOP, SINK, 120V OUTLETFOR AUTOCLAVE,
UPPER CABINETS WITHUNDER CABINET LIGHTING
(INDICATED WITHDASHED LINES)
LAB210
PROVIDE HOBDRAIN AT FILM
PROCESSOR
TREAT.204
TREAT.205
PODIUM
CORR.010
CORR.100
CORR.200
A B C D E G I
1
2
4
7
8
3
F
H
B21L1-10
B21L1-10
B21L1-10
B3L2-18
A2EL1-2 B21
L2-18
A2L1-12c
A2L1-12b
A2EL1-12b
A2L1-12c
A2L1-12b
A2L1-12b
A2L1-12c
A2EL1-12c
A2L1-12c
A2L1-12c
A2L1-12a
A2L1-12a
A2EL1-12c
A2L1-12a
A2L1-12a
B21L2-18
B21L2-18
A2EL1-2f
A2L1-14f
A2EL1-2f
A2EL1-2f
B22L1-16
B22L1-16
B22L1-16
B22L1-16
B22L1-16
B22L1-16
B22L1-16
B22L1-16
A2L1-4
A2L1-4
A2L2-18
A2L2-18
A3L2-18a,b
A3EL2-18a,b
A2L1-6
A2EL1-2
A2L1-6
A3L2-18a,b
A3L2-18a,b
A3EL2-18a,b
A3L2-18a,b
D1L2-18c
D1L2-18c
A3L1-8a
A3L1-8a
A3EL1-8c
A3L1-8a
A3L1-8a
A3L1-8c
A3L1-8b
A3EL1-8b
A3L1-8c
A3EL1-8b
A3L1-8b
A3L1-8c
A3EL1-10a,b
B21L1-10
A3L1-10a,b
A3L1-10
A3L1-10
A3EL1-10a,b
A3L1-10
A3L1-10
A3L1-10a,b
A3L1-10
A3EL1-10
A3L1-10
A3L1-10
A2L1-8
A2L1-8 A2
L1-8A2L1-8
A2L2-18
A2L2-18
A2EL1-2f
A2L1-14f
A2EL1-2f
A2L1-14f
A2L1-14f
A2L1-14f
A2L1-14f
A2EL1-2f A2
L1-14f
A2L1-14f
A2L1-14g
A2EL1-2g
A2EL1-2g
A2L1-14g
A2EL1-2g
B21L1-4
A2FEL1-2
D1L1-4
D1L1-4
D1L1-4
D1EL1-4
D1EL1-4
D1L1-4
D1L1-4
D1L1-4
D1L1-8d
D1L1-8d
D1L1-8d
D1L1-12d
D1L1-12d
D1L1-12d
B21L1-16D1
L1-14g
D1L1-16
D1L1-16
A2L1-4
A3L1-8
A3EL1-8
A2L1-6
A2EL1-2
D1L1-6
D2L1-6
D2L1-6
D2L1-6
D2L1-6
D2L1-6
D2L1-6
D2L1-6
D2L1-6
D2L1-6
D2L1-6
D2L1-6
D2L1-6
A2EL1-2
D1L1-6
D3L1-6
D1L1-6
C1EL1-2
C1EL1-2
X1L1-12
X1L1-12
X1L1-2
X1L1-2
X1L1-2
X1L1-10
X1L1-10
X1L1-8
X1L1-2
X1L1-2
X1L1-8
X1L1-2
X1L1-2
D1L1-14f
D1L1-14f
D1L1-14g
C1L1-6
C1L1-6
C1L1-6
C1L1-6
C1L1-6
C1L1-6
X4L1-4
X4L1-4
D3EL2-20
D3L2-20
D3EL2-20
D3L2-20
D3EL2-20
D3L2-20
D3L2-20
T1L2-20
T1L2-20
T1L2-20
1
DS-2DS-222
B21L2-18
1
DS-22
DS-
2
2
C2L1-4
C2L1-4
A2L1-6
A2L1-6
A2FEL1-2
D1L1-14f
FL1-4
FL1-4
FL1-4
FL1-4
FL1-4
FL1-4
D3EL2-20
D3L2-20
D3L2-20
D3L2-20
D3L2-20
D3L2-20
D1L2-18c
D3L2-20
D3L2-20
G2 G2 G2
G4
C1L1-6
C1L1-6
1
DHC
DHC
d
d
3
4
c
4
4
4
4
4
X1L1-2
ba
LCP
5
4
4
ba
ba
ab
f
f
g
g
1
1
COORDINATE WITH ARCHITECTURAL REFLECTED CEILING PLAN FOR CEILINGTYPES AND EXACT LOACTIONS OF LIGHT FIXTURES .
ROUTE ALL LIGHTING CIRCUITS VIA LIGHTING CONTROL PANEL, UNLESSOTHERWISE NOTED.
EXTERIOR BUILDING LIGHTING TO BE CONTROLLED BY THE INTERNAL TIMECLOCK OF THE LIGHTING CONTROL PANEL AND BY AN EXTERIOR PHOTOCELLMOUNTED ON THE BUILDING ROOF.
ROUTE UNSWITCHED PHASE CONDUCTOR TO ALL BATTERY BACK-UP FIXTURESPER MANUFACTURER'S REQUIREMENTS. REFER TO DETAIL ON ELECTRICALDETAILS SHEET.
ALL EXIT SIGNS SHALL BE NON-SWITCHED. FURNISH AND INSTALL ADDITIONALUNSWITCHED PHASE CONDUCTOR WHICH BYPASSES LOCAL AND CENTRALIZEDLIGHTING CONTROLS.
COORDINATE EXACT LOCATIONS AND QUANTITIES OF CEILING-MOUNTEDSENSORS WITH MANUFACTURER'S REQUIREMENTS PRIOR TO ROUGH-IN.
COORDINATE CEILING-MOUNTED SENSOR LOCATIONS WITH OTHER CEILING-MOUNTED EQUIPMENT SUCH AS LIGHTING FIXTURES, HVAC DIFFUSERS, SMOKEDETECTORS, SPRINKLER HEADS, ETC. DO NOT INSTALL CEILING-MOUNTEDSENSORS CLOSER THAN 2' TO HVAC DIFFUSERS OR RETURNS.
A.
B.
C.
D.
E.
F.
G.
FURNISH AND INSTALL 4-BUTTON LOW-VOLTAGE SWITCH CONNECTED TO LCP TOPROVIDE OVERRIDE CONTROL OF BUILDING LIGHTING.
REFER TO DAYLIGHTING SCHEME #2 DETAIL ON ELECTRICAL DETAILS SHEET.
CIRCUIT UNDERCABINET LIGHTS TO NEAREST NON-DEDICATED BRANCH RECEPTACLECIRCUIT.
ONE SWITCH TO CONTROL IN-BOARD LAMPS AND OTHER SWITCH TO CONTROL OUT-BOARD LAMPS FOR ALL FIXTURES IN THIS ROOM.
FURNISH AND INSTALL USER-PROGRAMMABLE LIGHTING CONTROL PANEL WITHCAPACITY FOR 32 RELAYS, LOCKABLE ENCLOSURE, ASTRONOMICAL TIME CLOCK, ANDEXTERNAL MANUAL OVERRIDE ADJACENT TO PANEL. HUBBELL "LX-32" SERIES ORAPPROVED EQUAL. PROVIDE WITH (16) SINGLE-POLE RELAYS AND (3) DOUBLE-POLERELAYS.
1.
2.
3.
4.
5.
GENERAL NOTES
# PLAN KEYNOTES:
NON-RATED PARTITION
SYMBOL DESCRIPTION DOOR/DAMPER PRIORITY
WALL LEGEND
1-HOUR FIRE PARTITION
1-HOUR FIRE BARRIER(INCIDENTAL USE-IBC/HAZARDOUS-LSC)
---
20 MIN, CLOSER, S DAMPERS
POSITIVE LATCH, 45 MIN,CLOSER, NO DAMPERS IFHARD DUCTED
(1ST)
(2ND)
(-)
REFER TO W1.1 & W1.2 FOR ADDITIONAL INFO.INC.USE = INCIDENTAL USE
PROJECT NUMBER
DATE
This drawing shall not be reproduced, published, stored in an electronic retrieval system, or used in any way without written permission of the Architect. Copyright © Johnson Johnson Crabtree Architects P. C.
4551
Tro
usda
le D
rive
Nas
hville
, TN
372
04te
lfa
x61
5.83
7.06
5661
5.83
7.06
57Jo
hnso
n Jo
hnso
nC
rabt
ree
Arc
hite
cts
P.C
.
JJC
A
Cumulative Sheet Re-Issue
(Individual revisions cloudedand labeled within sheet)
4633 Trousdale DriveNashville, TN 37204Phone: 615.661.6211Env Project #15104.00
August 16, 2016
2016
15654.01
August 3, 2016
E1.1Lighting First Floor
TC
AT D
icks
onD
icks
on, T
N
A Ne
w He
alth
Bui
ldin
g Fo
r:
CONSTRUCTION DOCUMENTS - SBC #166/000-04-2013M1
8'08'
Lighting First Floor
![Page 25: JJCA - Amazon Simple Storage Service · Project Manual For A New Health Building for TCAT Dickson Dickson, TN JJCA Project #15654.01 SBC # 166/000-04-2013M1 August 3rd, 2016 TFM Number:](https://reader031.fdocuments.us/reader031/viewer/2022020305/5c303a0b09d3f217118b56e5/html5/thumbnails/25.jpg)
F
F
F
F
F
F
FAC
P
FAA
S
S
F
F
F
S
F
S
SS
F
SS
F
SS
S
S
S
F
S
F
F
FS
CR
CR
CR
CR
CR
D
D
D
D
D
S
F
F
F
J
J
J
DH
DH
F
F
CR CRJ
D
J
D
J
COORDINATE EXACT LOCATION OF MECHANICAL EQUIPMENT WITH MECHANICALDRAWINGS.
FOR ALL VOICE/DATA DEVICE LOCATIONS, PROVIDE ROUGH-IN AND 1" CONDUITSTUBBED UP TO ABOVE ACCESSIBLE CEILING. CABLING TO BE PROVIDED BY THEOWNER.
COORDINATE LOCATIONS OF AND CONNECTIONS TO DUCT-MOUNTED SMOKEDETECTORS AT COMBINATION FIRE/SMOKE DAMPERS WITH HVAC DUCTWORKINSTALLATION.
LOCATE ALL FIRE ALARM RELAYS WITHIN THREE FEET OF THE DEVICE BEINGCONTROLLED.
FIRE ALARM CONDUCTORS SHALL BE INSTALLED IN CONDUIT.
CEILING SMOKE DETECTORS SHALL NOT BE LOCATED WITHIN THREE FEET OF ASUPPLY AIR GRILLE.
LOCATE ALL FIRE ALARM RELAYS WITHIN THREE FEET OF THE DEVICE BEINGCONTROLLED.
INDIVIDUAL FIRE ALARM NOTIFICATION DEVICE CANDELA (cd) AND DECIBEL (dBA)RATINGS LISTED ARE MINIMUM DEVICE REQUIREMENTS.
A.
B.
C.
D.
E.
F.
G.
H.
SINGLE-GANG BOX FOR INTRAORAL X-RAY CONNECTION.
CONDUIT TO BE INSTALLED UP TO ABOVE CEILING SPACE AND OVER AND DOWN TOREMOTE X-RAY SWITCH. FURNISH AND INSTALL 3#18 LOW-VOLTAGE WIRE IN (1) 3/4"CONDUIT WITH MINIMUM 6" OF WIRE AT EACH END.
CONDUIT TO BE STUBBED UP FLUSH WITH FLOOR.
(1) EMPTY 2" CONDUIT RUN UNDERSLAB TO WALL AND STUBBED UP TO ABOVEACCESSIBLE CEILING.
SINGLE-GANG BOX FOR REMOTE X-RAY SWITCH.
COORDINATE EXACT LOCATIONS, MOUNTING HEIGHTS, AND CONNECTIONREQUIREMENTS WITH DENTAL EQUIPMENT VENDOR FOR ALL DEVICES IN THIS AREA
FURNISH AND INSTALL PER TYPICAL TREATMENT ROOM.
FIRE ALARM CONTROL PANEL SHALL ALSO CONTAIN A MICROPHONE AND AMPLIFIERFOR VOICE NOTIFICATION. PROVIDE ADDITIONAL HARDWARE REQUIRED TO CONNECTTO VOICE NOTIFICATION SYSTEM IN EXISTING MAIN BUILDING. ALSO PROVIDEADDITIONAL HARDWARE REQUIRED TO CONNECT FACP TO EXISTING FIRE ALARMSYSTEM IN EXISTING MAIN BUILDING.
120V POWER CONNECTION TO SMOKE AND COMBINATION FIRE/SMOKE DAMPERS INTHIS AREA. REFER TO MECHANICAL DRAWINGS FOR LOCATIONS. FURNISH ANDINSTALL A FIRE ALARM MONITOR MODULE AND A 120V/1P TOGGLE SWITCHDISCONNECT AT EACH DAMPER. FURNISH AND INSTALL (1) FIRE ALARM MONITORMODULE PER CIRCUIT.
VAV POWER SUPPLY. FURNISH AND INSTALL 120V TOGGLE SWITCH FOR DISCONNECT.
FURNISH AND INSTALL 3-GANG EXTRA DEEP BOX FOR A/V CONNECTIONS. MOUNTBEHIND DISPLAY WITH (1) 1-1/4" CONDUIT STUBBED UP INTO ACCESSIBLE CEILINGABOVE. COORDINATE WITH A/V VENDOR DRAWINGS PRIOR TO ROUGH-IN.
120V POWER CONNECTION FOR TEMPERATURE CONTROL PANEL. COORDINATEEXACT LOCATION WITH MECHANICAL.
DATA OUTLET FOR CEILING-MOUNTED PROJECTOR. OUTLET SHALL BE MOUNTEDABOVE CEILING. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH A/VVENDOR PRIOR TO ROUGH-IN.
REFER TO POWER FIRST FLOOR PLAN FOR FLOOR BOX INFORMATION. COORDINATEDEVICE REQUIREMENTS WITH LOW-VOLTAGE VENDOR.
120V POWER CONNECTION FOR DENTAL AIR AND VACUUM PUMP CONTROL PANEL.COORDINATE EXACT LOCATION AND REQUIREMENTS WITH PLUMBING.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
GENERAL NOTES
# PLAN KEYNOTES:
1
SIM. LAB110
OFFICE108
LKRS.101
LOCKERS201
CLASSROOM206
COMM103
LAUNDRY105
DARKROOM211
AIR COMP.212
TREAT.203
TREAT.202
X-RAY209
CLASSROOM102
CLASSROOM113
239 SFSTORAGE
112
86 SFSTORAGE
207
105 SFOFFICE
208
WORK/VIEWING106
OFFICE107
OFFICE109
73 SFSTORAGE
111
233 SFMECH
00579 SFELEC006
196 SFTLT.007
62 SFJAN008
194 SFTLT.009
253 SFVENDING
004
REF
PANTOS 16
LAPTOP CART
CV5R
AIRSTAR21
24 HALF-HEIGHTLOCKERS ANDCOAT HOOKS
56 HALF-HEIGHTLOCKERS ANDCOAT HOOKS
VENDINGMACINES
1315 SFLOBBY
002
RESOURCESHELVES
104
VEST001
VEST003
PODIUM
PODIUM
REF
TV
CO
AT
HO
OK
S
DW
STERILIZATION AREA: 30"-DEEPCOUNTERTOP, SINK, 120V OUTLETFOR AUTOCLAVE,
UPPER CABINETS WITHUNDER CABINET LIGHTING
(INDICATED WITHDASHED LINES)
LAB210
PROVIDE HOBDRAIN AT FILM
PROCESSOR
TREAT.204
TREAT.205
PODIUM
CORR.010
CORR.100
CORR.200
A B C D E G I
1
2
4
7
8
3
F
H
1
5
2
3
4
DAC-1DVP-1
WH-1 PP-1
B-1B-2
HWP-1HWP-2
HWP-4HWP-3
DPS
DPS
DPS
DPS
DPS DPS
DPS
DPS
75cd80dBA
WP
TYPICAL TREATMENT ROOM
8
9
9
9
6
15cd60dBA
15cd
15cd
15cd
30cd80dBA
15cd
15cd60dBA
15cd
15cd60dBA
15cd
15cd50dBA
15cd
15cd
15cd
15cd
30cd60dBA
30cd60dBA
15cd60dBA
75cd60dBA
75cd60dBA
75cd60dBA
75cd
11
L2-15
AH-1
L1-28
L1-30
L1-32
12L1-34
13
13
13
DVP-2
14
14
14
7
7
7
PSL2-22
10
15cd
15
L3-46
60dBA
WP
75cd80dBA
15cd60dBA
15cd60dBA
15cd60dBA
75cd60dBA
D S
D R D R
NON-RATED PARTITION
SYMBOL DESCRIPTION DOOR/DAMPER PRIORITY
WALL LEGEND
1-HOUR FIRE PARTITION
1-HOUR FIRE BARRIER(INCIDENTAL USE-IBC/HAZARDOUS-LSC)
---
20 MIN, CLOSER, S DAMPERS
POSITIVE LATCH, 45 MIN,CLOSER, NO DAMPERS IFHARD DUCTED
(1ST)
(2ND)
(-)
REFER TO W1.1 & W1.2 FOR ADDITIONAL INFO.INC.USE = INCIDENTAL USE
PROJECT NUMBER
DATE
This drawing shall not be reproduced, published, stored in an electronic retrieval system, or used in any way without written permission of the Architect. Copyright © Johnson Johnson Crabtree Architects P. C.
4551
Tro
usda
le D
rive
Nas
hville
, TN
372
04te
lfa
x61
5.83
7.06
5661
5.83
7.06
57Jo
hnso
n Jo
hnso
nC
rabt
ree
Arc
hite
cts
P.C
.
JJC
A
Cumulative Sheet Re-Issue
(Individual revisions cloudedand labeled within sheet)
4633 Trousdale DriveNashville, TN 37204Phone: 615.661.6211Env Project #15104.00
August 16, 2016
2016
15654.01
August 3, 2016
E3.1Systems First Floor
TC
AT D
icks
onD
icks
on, T
N
A Ne
w He
alth
Bui
ldin
g Fo
r:
CONSTRUCTION DOCUMENTS - SBC #166/000-04-2013M1
8'08'
Systems First Floor
DECIBLE RATINGS HAVE BEENADDED TO ALL AUDIBLEDEVICES ON THIS SHEET.
1