ITR LOAD BREAK SWITCHRated making short circuit current Ima kA 20 (ITR-L) 31,5 (ITR-N) ELECTRICAL...

2
ITR OUTDOOR VACUUM BREAKING SWITCH UP TO 52kV MAIN FEATURES • Used for railway electrification of catenaries and feeders. • Arrangement in horizontal position, single-pole or group operated. Options: earthing switch, enclosed/cubicle, grease free version for low maintenance. • Standards references : IEC 62271-1/103, EN 50152-2. TECHNICAL FEATURES Condition of use Outdoor Operating temperature range -25°C / +40°C (option : special service conditions) Seismic withstand ≤ 0,2 g (option : higher service conditions) Ice operation 10 mm (option: higher service conditions) SERVICE CONDITIONS FP107e 2018-08 Rated voltage Ur kV 25 Rated lightning impulse withstand voltage (BIL) Up kV 250 Rated frequency Fr Hz 50/60 Rated current Ir A 2 000 Short time current Ik max kA 31,5 Rated making short circuit current Ima kA 20 (ITR-L) 31,5 (ITR-N) ELECTRICAL Mechanical endurance / lifetime 10 000 operations - Creepage distance Cl3 (d) Cl4 (e) Insulator type Porcelain (brown) Composite Primary terminals Copper pads Tinned copper or silver plated copper MECHANICAL standard option OPTIONAL DEVICES Configurations Enclosed, grease free version Operating mechanisms Electrical drive or manual drive Earthing switch position 1 side Earthing switch operation type Independant or automatic Ik earthing switch (kA/1s) Disconnector values (contact us for 3s values) Interlocking device Mechanical ZAC du Saut du Moine • 38800 Champagnier • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com * When disconnector opens, earthing switch closes and conversely. For other values, please contact us. peak values (Ip peak) in kA for short time currents: 31,5kA: 82. LOAD BREAK SWITCH

Transcript of ITR LOAD BREAK SWITCHRated making short circuit current Ima kA 20 (ITR-L) 31,5 (ITR-N) ELECTRICAL...

Page 1: ITR LOAD BREAK SWITCHRated making short circuit current Ima kA 20 (ITR-L) 31,5 (ITR-N) ELECTRICAL Mechanical endurance / lifetime 10 000 operations - Creepage distance Cl3 (d) Cl4

ITROUTDOOR VACUUM BREAKING SWITCH UP TO 52kV

MAIN FEATURES• Used for railway electrification of catenaries and feeders.• Arrangement in horizontal position, single-pole or group operated. Options: earthing switch, enclosed/cubicle, grease free version for low maintenance. • Standards references : IEC 62271-1/103, EN 50152-2.

TECHNICAL FEATURES

Condition of use OutdoorOperating temperature range -25°C / +40°C (option : special service conditions)Seismic withstand ≤ 0,2 g (option : higher service conditions)Ice operation 10 mm (option: higher service conditions)

SERVICE CONDITIONS

FP107e 2018-08

Rated voltage Ur kV 25Rated lightning impulse withstand voltage (BIL) Up kV 250

Rated frequency Fr Hz 50/60Rated current Ir A 2 000Short time current Ik max kA 31,5Rated making short circuit current Ima kA 20 (ITR-L) 31,5 (ITR-N)

ELECTRICAL

Mechanical endurance / lifetime 10 000 operations -Creepage distance Cl3 (d) Cl4 (e)Insulator type Porcelain (brown) Composite

Primary terminals Copper pads Tinned copper or silver plated copper

MECHANICAL standard option

OPTIONAL DEVICES

Configurations Enclosed, grease free version

Operating mechanisms Electrical drive or manual drive Earthing switch position 1 sideEarthing switch operation type Independant or automaticIk earthing switch (kA/1s) Disconnector values (contact us for 3s values)Interlocking device Mechanical

ZAC du Saut du Moine • 38800 Champagnier • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com

* When disconnector opens, earthing switch closes and conversely. For other values, please contact us.

peak values (Ip peak) in kA for short time currents: 31,5kA: 82.

LOA

D B

REA

K S

WIT

CH

Page 2: ITR LOAD BREAK SWITCHRated making short circuit current Ima kA 20 (ITR-L) 31,5 (ITR-N) ELECTRICAL Mechanical endurance / lifetime 10 000 operations - Creepage distance Cl3 (d) Cl4

ITROUTLINE DRAWING

Due

to

prod

uct

evol

utio

ns, i

nfor

mat

ion

is s

ubje

ct t

o ev

olut

ions

and

val

id o

nly

afte

r co

nfirm

atio

n

RELATED EQUIPMENT

SBRROCKING

DISCONNECTOR

IT25NVACUUM

BREAK SWITCH

MR41EUNIVERSAL SMART

DRIVE

S-TORQUE MECHANICAL FAILURE

AND POSITION DETECTION

S-VOLTVOLTAGE DETECTOR

S-COM REMOTE CONTROL

BOARD

ZAC du Saut du Moine • 38800 Champagnier • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com

* H = Horizontal. Above are mentionned maximum dimensions, tolerance +10%. For other values, please consult us.

25kV 1250A H* 1320 1050 310 826 35550

52kV 2000A H* 1380 1095 310 887 355

Ur Ir max

Term

inal

s A B B’ C D Weight/pole(approx.)

mm mm mm mm mm kg

The drawing above is given for information only. Detailed layout and digital drawing available on request.

B’

C

85

D

A

B

open gap310 ±30

52° ±3°

to close