Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto...

56
Daisy Kuo Assistant Product Manager E-mail: [email protected] BDBiosciences Introduction to Flow Cytometry -- BD FACSCanto II TM

Transcript of Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto...

Page 1: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

Daisy KuoAssistant Product ManagerE-mail: [email protected]

Introduction to Flow Cytometry

-- BD FACSCanto IITM

Page 2: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

2

Outline

• Basic Concept of Flow Cytometry

• FACSCanto II System Introduction

• Application Examples

Page 3: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

3

What is Flow Cytometry?

• Flow = Fluid• Cyto = Cell• Metry = Measurement

• A variety of measurements are made on cells, cell organelles, and other objects suspended in a liquid and flowing at rates of several thousands per second through a flow chamber.

Page 4: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

4

Particle Size

• Detection range: 0.5~50um

Page 5: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

5

What Can a Flow Cytometer Tell Us About a Cell?

Its relative size (Forward Scatter—FSC)

Its relative granularity or internal complexity (Side Scatter—SSC)

Its relative fluorescence intensity

Page 6: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

6

Scatter Light

FSC Sensor

Laser

SSC Sensor

Page 7: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

7

Lysed Whole Blood

Forward Scatter

Sid

e S

catte

r

Lymphocytes

Monocytes

Neutrophils

Page 8: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

8

Fluorescence Light

Page 9: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

9

Fluorescence

Page 10: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

10

BD FACSCanto IITM

Page 11: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

11

Subsystems

FluidicsTo introduce and focus the cells for interrogation.

OpticsTo generate and collect the light signals.

ElectronicsTo convert the optical signals to proportional digital signals, process the signals, and communicate with the computer.

Page 12: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

12

sheath sheathsample

Sample Flow

Hydrodynamic Focusing

Excitation Lasers

Page 13: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

13

Sample Differential

Sample

High Sample Pressure

120 µL/min

High Differential Pressure

LaminarFlow

Sheath Sheath

LaminarFlow

Low Differential Pressure

Sheath SheathSample

Low Sample Pressure

12 µL/min

Page 14: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

14

Optics

• Excitation optics– Lasers Lenses to shape and focus the laser beam

• Collection optics– A collection lens to collect light emitted from the

article-laser beam interaction– A system of optical mirrors and filters to route

specified wavelengths of emitted light to designated optical detectors

Page 15: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

15

Fluorochrome Spectra

Page 16: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

16

Excitation Optics

• Spatially separated laser beams lower the possibility of fluorescence spillover

Page 17: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

17

Collection Optics

Page 18: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

18

Optics-- ConfigurationOther Fluorochrome

GFP

PI

PI, PE-Cy5.5, 7-AAD

Alexa Fluor® 633

DAPI, Hoechst Dye

Cascade Blue®

Page 19: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

19

PMTs and preamps convert photons to voltage pulses.

Analog-to-digital converters translate analog signals to proportional digital signals.

Compute area and height for each pulse.

Perform compensation and calculate ratios and width.

An embedded computer interfaces with the computer workstation for data transfer.

Electronics

Page 20: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

20

Creation of a Voltage Pulse

Laser

Time (µs)

Volts

Pul

se H

eigh

t

Pulse Width

Page 21: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

21

Analog-to-Digital Converter

Baseline

16,364

Time

937

1,985

7,650

12,420

Hei

ght

351

383

375

406

377

318

367

319

375

423

432

937

1985

7650

1242

015

300

1325

657

9124

7184

243

333

131

130

837

634

941

482

313

7390

351

433

841

830

731

735

331

370

340

337

830

840

640

530

335

340

532

8

Digitized values

Page 22: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

22

Quantification of a Voltage Pulse

Page 23: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

23

Doublet Discrimination

Page 24: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

24

39,27139,271

Data Storage

Event 1Event 2Event 3

FSC SSC FITC PE0 60 120 89

10 160 65

30 650 160

List-Mode Data

39,271

89

675 30,621PE

FITC

675Time

PEFI

TC

39,271

22,688

30,621

6,189

Page 25: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

25

Data Display: Linear vs Log

Page 26: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

26

Spectral Overlap– Compensation Theory

APC PerCPPI

Wavelength (nm)400 500 600 700

100%

0%

Pacific Blue

Nor

mal

ized

Inte

nsity

FITC PEAmCyan PerCP-Cy5.5

800

PE-Cy7

Page 27: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

27

Spillover

FITC PE PerCP-Cy5.5

650 700

PerCP-Cy5.5695/40

500 600

FITC530/30

Rel

ativ

e In

tens

ity

Wavelength (nm)

550

PE585/42

PE-Cy7

PE-Cy7780/60

750 800

Page 28: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

28

FITC Spillover

650 700

PerCP-Cy5.5695/40

500 600

FITC530/30

Rel

ativ

e In

tens

ity

Wavelength (nm)

550

PE585/42

750 800

FITC

FITC

PEP

erC

P-C

y5.5

Page 29: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

29

650 700

PerCP-Cy5.5695/40

500 600

FITC530/30

Rel

ativ

e In

tens

ity

Wavelength (nm)550

PE585/42

FITC CompensationTo lower cluster, increase value.

FITC FITC

FITC

Per

CP

-Cy5

.5

FITC

Per

CP

-Cy5

.5

PE-%FITC

PerCP-Cy5.5-%FITC

Page 30: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

30

Compensation Examples

Correct Compensation Undercompensation Overcompensation

Incorrect Compensation

Page 31: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

31

Review

Time

Time

Time

Time

Time

Data Processing

PE

FITC

SS

C

FSC

AP

C

PerCP-Cy5.5

Time

Page 32: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

ApplicationExamples

Page 33: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

33

Applications

• Phenotype Analysis (Cell Surface Antigens/Markers)• Intracellular Analysis

-- Eg. Cytokines, Signal Transduction molecules…etc.

• DNA Analysis-- Eg. Viability, Cell cycle, Apoptosis…etc.

• Cell Fuction Analysis-- Eg. Free radicals, Ca2+, Reporter genes…etc.

• CBA (Cytometric Bead Array)• Others

Page 34: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

34

• Ligand• Receptor• Adhesion molecule• …etc

Phenotype Analysis

Page 35: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

35

Lymphocyte Immunophenotyping

Granulocytes

Monocytes

Eosinophils

Basophils

NeutrophilsLymphocytes

T B NK

T Helper

TCytotoxic

Peripheral White Blood CellsCD45+

CD3+

CD4+ CD3+

CD8+

CD3+

CD3-

CD19+

CD3-

CD16+

CD56+

Monocytes

Page 36: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

36

Page 37: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

37

Permeabilizing solution

• Cytokine• Enzyme• signal transduction

molecule• …etc.

Intracellular Analysis

Fixation solution

Page 38: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

38

Cytokine Detection

Picture From www.fredonia.edu

Page 39: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

39

CD3CD28

PHA

Con A

IonomycinLPS

T cell

Stimulation

Fixation

Secretion stop(Brefeldin A or Monensin)

Only in vitro

PermeabilisationIntracellular Staining

To enhance the accumulation of intracellular cytokines.

Monensin: Cytokines accumulate in the ERBrefeldin A: in Golgi complex.

To maintain structural integrity.Formaldehyde or glutaraldehydeKeep the protein structure and doesn't change the(accessibility of the) epitopes too much

Saponin (permeablisation buffer).

Page 40: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

40

Combination of Cell Surface and Cytoplasmic Staining

Th1/Th2/Th17 Phenotyping Kit

Page 41: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

41

Signal Transduction

Page 42: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

42

Intracellular Staining in Activated Lysed Whole Blood

Page 43: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

43

DNA Analysis

Detergent

Nucleic Acid Dye

Ethanol

Page 44: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

44

G2M G0

G1

s

0 200 400 600 800 1000

G0G1

s G2 M

DNA content

Count

2N 4N

Cell Cycle Analysis

Page 45: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

45

Apoptosis (Sub G1)

Page 46: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

46

• Membrane Potential (DiOC6, JC-1)

• Oxidative Metabolism (Free Radicals)

• Intracellular PH Value (Snarf-1)

• Ca++ Influx (Fluo-4/Fura Red, Indo-1)

• Phagocytosis

• Cell Proliferation (PI, BrdU, Intracellular Cyclins)

• Apoptosis (Annexin V, active Caspase-3)

Cell Function Analysis

Page 47: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

47

C a++ C a++C a++

C a++

Externalization ofphosphatidylserine

Plasmamembrane

Apoptosis

Cytoplasm Cytoplasm

Annexin V-FITCconjugate

Annexin V Assay

Page 48: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

48

Annexin V/PI Double Staining

Bordón et al. Radiation Oncology 2009 4:58

Page 49: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

49

Cytometric Beads Array (CBA)

Single StepIncubation

Two-StepIncubation

or

Page 50: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

50

Beads Provide a Flexible Platform

Multiple sizes

Different fluorescence

intensities

Different colors with different intensities

Page 51: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

51

Advantages of Bead-Based Immunoassays• Analyze multiple analytes simultaneously• Reduced sample volume requirements• Reduced hands-on time by parallel analysis of samples• Wide dynamic range of fluorescence detection (requires

fewer sample dilutions)

Page 52: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

52

Proteins MeasuredA. Interleukin (IL)-2B. IL-4C. IL-5D. IL-10E. Tumor Necrosis Factor-F. Interferon-

Page 53: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

53

Cytometry Beads Array (CBA)

Page 54: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

54

Standard Curves

Page 55: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

55

CBA Flex Sets• Open configuration (Up to 30 plex)• Clustering based on Red and NIR fluorescence intensity• Need to be used at dual-laser(488nm blue v.s 633nm red) instrument

Page 56: Introduction to Flow Cytometry -- BD FACSCanto IIhomepage.ntu.edu.tw/~ntutechcomm/TCX/file/FACSCanto II... · 2019-08-13 · 21 Analog-to-Digital Converter Baseline 16,364 Time 937

56

CBA Functional Beads• Can be conjugated with any Ab