INSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC RANGE WITH DOUBLE OVENS Table of Contents RANGE SAFETY ......................................................................... 2 INSTALLATION REQUIREMENTS ............................................ 3 Tools and Parts........................................................................ 3 Location Requirements ........................................................... 3 Electrical Requirements........................................................... 5 INSTALLATION INSTRUCTIONS .............................................. 6 Unpack Range ......................................................................... 6 Adjust Leveling Legs................................................................ 6 Install Anti-Tip Bracket ............................................................ 7 Electrical Connection............................................................... 8 Verify Anti-Tip Bracket Location............................................ 13 Level Range ........................................................................... 14 Complete Installation ............................................................. 14 Moving the Range.................................................................. 15 IMPORTANT: Save for local electrical inspector's use. W10270322A

Transcript of INSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC · PDF fileINSTALLATION INSTRUCTIONS...

Page 1: INSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC · PDF fileINSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC RANGE WITH ... If installing a range hood or microwave hood ... *The NEC

INSTALLATION INSTRUCTIONSFREESTANDING ELECTRIC RANGE WITH DOUBLE OVENS

Table of ContentsRANGE SAFETY ......................................................................... 2INSTALLATION REQUIREMENTS............................................ 3

Tools and Parts........................................................................ 3Location Requirements ........................................................... 3Electrical Requirements........................................................... 5

INSTALLATION INSTRUCTIONS.............................................. 6Unpack Range ......................................................................... 6Adjust Leveling Legs................................................................ 6Install Anti-Tip Bracket ............................................................ 7Electrical Connection............................................................... 8Verify Anti-Tip Bracket Location............................................ 13Level Range ........................................................................... 14Complete Installation............................................................. 14Moving the Range.................................................................. 15

IMPORTANT: Save for local electrical inspector's use.

W10270322A

Page 2: INSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC · PDF fileINSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC RANGE WITH ... If installing a range hood or microwave hood ... *The NEC

2

RANGE SAFETY

You can be killed or seriously injured if you don't immediately

You can be killed or seriously injured if you don't follow

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what canhappen if the instructions are not followed.

Your safety and the safety of others are very important.We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

This is the safety alert symbol.

This symbol alerts you to potential hazards that can kill or hurt you and others.

All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”These words mean:

follow instructions.

instructions.

DANGER

WARNING

WARNINGTip Over Hazard

A child or adult can tip the range and be killed.

Connect anti-tip bracket to rear range foot.

Reconnect the anti-tip bracket, if the range is moved.

Failure to follow these instructions can result in death or serious burns to children and adults.

Page 3: INSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC · PDF fileINSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC RANGE WITH ... If installing a range hood or microwave hood ... *The NEC

3

INSTALLATION REQUIREMENTSTools and Parts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.Tools needed

Parts suppliedCheck that all parts are included.■ 3 - 10–32 hex nuts (attached to terminal block)

■ 3 - Terminal lugs

■ Oven racks

■ 2 - #12 x 1⁵⁄₈" screws (for mounting anti-tip bracket)

■ Anti-tip bracket (taped inside upper oven with literature package)

Anti-tip bracket must be securely mounted to back wall or floor. Thickness of floor may require longer screws to anchor bracket to subfloor. Longer screws are available from your local hardware store.

Parts neededIf using a power supply cord:■ A UL listed power supply cord kit marked for use with ranges.

The cord should be rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 1³⁄₈" (3.5 cm) diameter connection opening and must end in ring terminals or open-end spade terminals with upturned ends.

■ A UL listed strain relief.

Check local codes. Check existing electrical supply. See “Electrical Requirements” section.It is recommended that all electrical connections be made by a licensed, qualified electrical installer.

Location RequirementsIMPORTANT: Observe all governing codes and ordinances.■ It is the installer’s responsibility to comply with installation

clearances specified on the model/serial number rating label. The model/serial number rating label is located on the bottom right front of the toe kick plate.

■ The range should be located for convenient use in the kitchen.

■ To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of the cabinets.

■ Cabinet opening dimensions that are shown must be used. Given dimensions are minimum clearances.

■ The floor anti-tip bracket must be installed. To install the anti-tip bracket shipped with the range, see “Install Anti-Tip Bracket” section.

■ Grounded electrical supply is required. See “Electrical Requirements” section.

IMPORTANT: To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage. This range has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194°F (90°C).

Mobile Home - Additional Installation RequirementsThe installation of this range must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280). When such standard is not applicable, the Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A or with local codes.Mobile home installations require:■ When this range is installed in a mobile home, it must be

secured to the floor during transit. Any method of securing the range is adequate as long as it conforms to the standards listed above.

■ Four-wire power supply cord or cable must be used in a mobile home installation. The appliance wiring will need to be revised. See “Electrical Connection” section.

■ Tape measure

■ Level

■ Phillips screwdriver

■ Flat-blade screwdriver

■ Wrench or pliers

■ ³⁄₈" nut driver

■ Hand or electric drill

■ ¹⁄₈" (3.2 mm) drill bit

Page 4: INSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC · PDF fileINSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC RANGE WITH ... If installing a range hood or microwave hood ... *The NEC

4

Product Dimensions

*Excludes handle. Dimension given is from wall to front of oven door and will vary based on electric outlet receptacle installation.

Cabinet Dimensions

Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height.IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.A freestanding range may be installed next to combustible walls with zero clearance.

NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet is covered by not less than ¹⁄₄" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet.

A. 46⁷⁄₈" (119.9 cm)B. Model/serial number rating

label (located on bottom right front of the toe kick plate)

C. 35⁷⁄₈" (91.4 cm) D. 29⁷⁄₈" (75.9 cm)E. 26⁵⁄₁₆" - 27¼" (66.8 - 69.2 cm)*

A

E*

D

C

B

A. 13" (33 cm) upper cabinet depth

B. 30" (76.2 cm) min. opening width

C. For minimum clearance to the top of the cooktop,see NOTE.

D. 30" (76.2 cm) min. opening width

E. Cabinet door or hinge should not extend into cutout.

F. 3-wire shaded area - 7" (17.8 cm) min. from left side cabinet, 5¾" (14.6 cm) max. from floor, 6" (15.2 cm) max. width*

G. 4-wire shaded area - 10" (25.4 cm) min. from right side cabinet, 5¾" (14.6 cm) max. from floor, 6" (15.2 cm) max. width*

H. 1½" (3.8 cm) min. from floor if using a flush mount outlet.

*Nothing located in shaded areas can extend more than 1½" (3.8 cm) from wall or range will not slide all the way back.

A

B

D

F

E

C

G

H

Page 5: INSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC · PDF fileINSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC RANGE WITH ... If installing a range hood or microwave hood ... *The NEC

5

Electrical RequirementsIf codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path and wire gauge are in accordance with local codes.Do not use an extension cord.Be sure that the electrical connection and wire size are adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition and all local codes and ordinances.A copy of the above code standards can be obtained from: National Fire Protection AssociationOne Batterymarch ParkQuincy, MA 02269.WARNING: Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service technician if you are in doubt as to whether the appliance is properly grounded. Do not modify the power supply cord plug. If it will not fit the outlet, have a proper outlet installed by a qualified electrician.

Electrical ConnectionTo properly install your range, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.■ Range must be connected to the proper electrical voltage and

frequency as specified on the model/serial number rating label. The model/serial number rating label is located on the bottom right front of the toe kick plate. Refer to the figures in the “Product Dimensions” section of the “Location Requirements” section.

■ This range is manufactured with the neutral terminal connected to the cabinet. Use a 3-wire, UL listed, 40- or 50-amp power supply cord (pigtail) (see following Range Rating chart). If local codes do not permit ground through the neutral, use a 4-wire power supply cord rated at 250 volts, 40 or 50 amps and investigated for use with ranges.

*The NEC calculated load is less than the total connected load listed on the model/serial number rating label.

**If connecting to a 50-amp circuit, use a 50-amp rated cord with kit. For 50-amp rated cord kits, use kits that specify use with a nominal 1³⁄₈" (34.9 mm) diameter connection opening.

■ A circuit breaker is recommended.

■ The range can be connected directly to the circuit breaker box (or fused disconnect) through flexible or nonmetallic sheathed, copper or aluminum cable. See “Electrical Connection.”

■ Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that the range can be moved if servicing is ever necessary.

■ A UL listed conduit connector must be provided at each end of the power supply cable (at the range and at the junction box).

■ Wire sizes and connections must conform with the rating of the range.

■ The wiring diagram is located on the back of the range or inside the storage drawer in a clear plastic bag.

If connecting to a 4-wire system:This range is manufactured with the ground connected to the neutral by a link. The ground must be revised so the green ground wire of the 4-wire power supply cord is connected to the cabinet. See “Electrical Connection.”Grounding through the neutral conductor is prohibited for new branch-circuit installations (1996 NEC); mobile homes; and recreational vehicles, or an area where local codes prohibit grounding through the neutral conductor.When a 4-wire receptacle of NEMA Type 14-50R is used, a matching UL listed, 4-wire, 250-volt, 40- or 50-amp, range power supply cord (pigtail) must be used. This cord contains 4 copper conductors with ring terminals or open-end spade terminals with upturned ends, terminating in a NEMA Type 14-50P plug on the supply end. The fourth (grounding) conductor must be identified by a green or green/yellow cover and the neutral conductor by a white cover. Cord should be Type SRD or SRDT with a UL listed strain relief and be at least 4 ft (1.22 m) long.

The minimum conductor sized for the copper 4-wire power cord are:40-amp circuit2 No.-8 conductors1 No.-10 white neutral1 No.-8 green grounding

If connecting to a 3-wire system:Local codes may permit the use of a UL listed, 3-wire, 250-volt, 40- or 50-amp range power supply cord (pigtail). This cord contains 3 copper conductors with ring terminals or open-end spade terminals with upturned ends, terminating in a NEMA Type 10-50P plug on the supply end. Connectors on the appliance end must be provided at the point the power supply cord enters the appliance. This uses a 3-wire receptacle of NEMA Type 10-50R.

Range Rating* Specified Rating of Power Supply Cord Kit and Circuit Protection

120/240 Volts 120/208 Volts Amps

8.8 - 16.5 KW16.6 - 22.5 KW

7.8 - 12.5 KW12.6 - 18.5 KW

40 or 50**50

4-wire receptacle (14-50R)

3-wire receptacle (10-50R)

Page 6: INSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC · PDF fileINSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC RANGE WITH ... If installing a range hood or microwave hood ... *The NEC

6

INSTALLATION INSTRUCTIONSUnpack Range

1. Remove shipping materials, tape and film from the range. Keep cardboard bottom under range.

2. Remove oven racks and parts package from inside oven.3. To place range on its back, take 4 cardboard corners from the

carton. Stack one cardboard corner on top of another. Repeat with the other 2 corners. Place them lengthwise on the floor behind the range to support the range when it is laid on its back.

4. Using 2 or more people, firmly grasp the range and gently lay it on its back on the cardboard corners.

5. Pull cardboard bottom firmly to remove.6. Use an adjustable wrench to loosen the leveling legs.7. Place cardboard or hardboard in front of range. Using 2 or

more people, stand range back up onto cardboard or hardboard.

Adjust Leveling Legs1. If range height adjustment is necessary, use a wrench or pliers

to loosen the 4 leveling legs.This may be done with the range on its back or with the range supported on 2 legs after the range has been placed back to a standing position.

NOTE: To place range back up into a standing position, put a sheet of cardboard or hardboard in front of range. Using 2 or more people, stand range back up onto the cardboard or hardboard.

2. Adjust the leveling legs to the correct height. Leveling legs can be loosened to add up to a maximum of 1" (2.5 cm). A minimum of ³⁄₁₆" (5.0 mm) is needed to engage the anti-tip bracket.NOTE: If height adjustment is made when range is standing, tilt the range back to adjust the front legs, then tilt forward to adjust the rear legs.

3. When the range is at the correct height, check that there is adequate clearance under the range for the anti-tip bracket. Before sliding range into its final location, check that the anti-tip bracket will slide under the range and onto the rear leveling leg prior to anti-tip bracket installation.

WARNINGExcessive Weight Hazard

Use two or more people to move and install range.

Failure to do so can result in back or other injury.

WARNING

Tip Over Hazard

A child or adult can tip the range and be killed.

Connect anti-tip bracket to rear range foot.

Reconnect the anti-tip bracket, if the range is moved.

Failure to follow these instructions can result in death or serious burns to children and adults.

Page 7: INSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC · PDF fileINSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC RANGE WITH ... If installing a range hood or microwave hood ... *The NEC

7

Install Anti-Tip Bracket1. Remove the anti-tip bracket that is taped inside the upper

oven with the package containing literature.2. Determine which mounting method to use: floor or wall.

If you have a stone or masonry floor you can use the wall mounting method.

3. Determine and mark edge of range in the cutout space. The mounting bracket can be installed on either the left side or right side of the cutout. Position mounting bracket in cutout so that right (or left) edge of the bracket is ¹⁵⁄₁₆" (2.4 cm) from the marked edge of the range, as shown.

4. Drill two ¹⁄₈" (3.0 mm) holes that correspond to the bracket holes of the determined mounting method. See the following.

Floor Mounting

Wall Mounting

5. Using the Phillips screwdriver, mount anti-tip bracket to the wall or floor with the two #12 x 1⁵⁄₈" screws provided.

A. Anti-tip bracketB. Mark edge of range.C. ¹⁵⁄₁₆" (2.4 cm)

A

B

C

A. #12 x 1⁵⁄₈" screwsB. Anti-tip bracket

A. #12 x 1⁵⁄₈" screwsB. Anti-tip bracket

A B

A B

Page 8: INSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC · PDF fileINSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC RANGE WITH ... If installing a range hood or microwave hood ... *The NEC

8

Electrical Connection - U.S.A. Only

Power Supply Cord Direct Wire

1. Disconnect power.2. Use Phillips screwdriver to remove the terminal block cover

screw located on the back of the range. Pull cover down and toward you to remove cover.

3. Remove plastic tag holding three 10-32 hex nuts from the middle post of the terminal block.

4. Add strain relief.

Style 1: Power supply cord strain relief■ Assemble a UL listed strain relief in the opening.

■ Feed the power supply cord through the strain relief in the cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.

■ Tighten strain relief screw against the power supply cord.

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use a new 40 amp power supply cord.

Plug into a grounded outlet.

Failure to follow these instructions can result in death, fire, or electrical shock.

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use 8 gauge copper or 6 gauge aluminum wire.

Electrically ground range.

Failure to follow these instructions can result in death, fire, or electrical shock.

A. UL listed strain relief

A

Page 9: INSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC · PDF fileINSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC RANGE WITH ... If installing a range hood or microwave hood ... *The NEC

9

Style 2: Direct wire strain relief■ Use Phillips screwdriver to remove screws and slide

cord/conduit plate down and out.

■ Position cord/conduit plate as shown in the following illustration.

■ Replace cord/conduit plate and insert screws.

■ Assemble a UL listed conduit connector in the opening.

■ Feed the flexible conduit through the strain relief, allowing enough slack to easily attach wiring to the terminal block.

■ Tighten strain relief screw against the flexible conduit.

5. Replace back panel and screws on rear of range.6. Complete installation following instructions for your type of

electrical connection:4-wire (recommended)

3-wire (if 4-wire is not available)

A. Removable retaining nutB. Strain relief

A

B

Page 10: INSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC · PDF fileINSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC RANGE WITH ... If installing a range hood or microwave hood ... *The NEC

10

Electrical Connection Options

4-wire connection: Power Supply Cord

Use this method for:■ New branch-circuit installations (1996 NEC)

■ Mobile homes

■ Recreational vehicles

■ In an area where local codes prohibit grounding through the neutral

1. Part of metal ground strap must be cut out and removed.

2. Use Phillips screwdriver to remove the ground-link screw from the back of the range. Save the ground link screw and the end of the ground-link under the screw.

3. Feed the power supply cord through the strain relief in the cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.

4. Use Phillips screwdriver to connect the green ground wire from the power supply cord to the range with the ground-link screw. The ground wire must be attached first.

5. Use ³⁄₈" nut driver to connect the neutral (white) wire to the center terminal block post with one of the 10–32 hex nuts.

6. Connect line 1 (black) and line 2 (red) wires to the outer terminal block posts with 10-32 hex nuts.

7. Securely tighten hex nuts.NOTE: For power supply cord replacement, only use a power cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 1³⁄₈" (3.5 cm) diameter connection opening, with ring terminals and marked for use with ranges.

8. Replace terminal block access cover.

If your home has: And you will be connecting to:

Go to Section:

4-wire receptacle(NEMA type 14-50R)

A UL listed, 250-volt minimum, 40-amp, range power supply cord

4-wire connection: Power supply cord

4-wire direct A fused disconnect or circuit breaker box

4-wire connection: Direct wire

3-wire receptacle(NEMA type 10-50R)

A UL listed, 250-volt minimum, 40-amp, range power supply cord

3-wire connection: Power supply cord

3-wire direct A fused disconnect or circuit breaker box

3-wire connection:Direct wire

A. Metal ground strapB. DiscardC. Ground-link screw

(12.7 cm)5"

3"(7.6 cm)

1"(2.5 cm)

ABC

A. Terminal blockB. Ground-link screwC. Cord/conduit plateD. Power supply cord wires

A. 10–32 hex nutB. Ground-link screwC. Line 1 (black)

D. Green ground wireE. Neutral (center) wire F. Line 2 (red)

A

B

CD

A

B

C

F

D

E

Page 11: INSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC · PDF fileINSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC RANGE WITH ... If installing a range hood or microwave hood ... *The NEC

11

3-wire connection: Power Supply Cord

Use this method only if local codes permit connecting chassis ground conductor to neutral wire of power supply cord.1. Feed the power supply cord through the strain relief in the

cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.

2. Use ³⁄₈" nut driver to connect the neutral (white) wire to the center terminal block post with one of the 10–32 hex nuts.

3. Connect line 1 (black) and line 2 (red) wires to the outer terminal block posts with 10-32 hex nuts.

4. Securely tighten hex nuts.NOTE: For power supply cord replacement, only use a power cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 1³⁄₈" (3.5 cm) diameter connection opening, with ring terminals and marked for use with ranges.

5. Replace terminal block access cover.

Direct Wire Installation: Copper or Aluminum Wire

This range may be connected directly to the fuse disconnect or circuit breaker box. Depending on your electrical supply, make the required 3-wire or 4-wire connection.1. Strip outer covering back 3" (7.6 cm) to expose wires. Strip

the insulation back 1" (2.5 cm) from the end of each wire.

2. Allow enough slack in the wire to easily attach the wiring terminal block.

3. Complete electrical connection according to your type of electrical supply (4-wire or 3-wire connection).

4-wire Connection: Direct Wire

Use this method for:■ New branch-circuit installations (1996 NEC)

■ Mobile homes

■ Recreational vehicles

■ In an area where local codes prohibit grounding through the neutral

1. Part of metal ground strap must be cut out and removed.

2. Use Phillips screwdriver to remove the ground-link screw from the back of the range. Save the ground-link screw and the end of the ground link under the screw.

A. Terminal blockB. Ground-link screwC. Cord/conduit plateD. Power supply cord wires

A. 10–32 hex nutB. Line 1 (black)C. Ground-link screw

D. Neutral (white) wireE. Line 2 (red)

A

C

B

D

A

B

C

D

E

A. Metal ground strapB. DiscardC. Ground-link screw

3"(7.6 cm)

1"(2.5 cm)

ABC

Page 12: INSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC · PDF fileINSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC RANGE WITH ... If installing a range hood or microwave hood ... *The NEC

12

3. Pull the conduit through the strain relief on cord/conduit plate on bottom of range. Allow enough slack to easily attach wiring to the terminal block.

4. Attach terminal lugs to line 1 (black), neutral (white), and line 2 (red) wires. Loosen (do not remove) the setscrew on the front of the terminal lug and insert exposed wire end through bottom of terminal lugs. Securely tighten setscrew to XX lbs-in. torque. See Bare Wire Torque Specifications chart.

Bare Wire Torque SpecificationsAttaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)

5. Use Phillips screwdriver to connect the bare (green) ground wire to the range with the ground-link screw. The ground wire must be attached first and must not contact any other terminal.

6. Use ³⁄₈" nut driver to connect the neutral (white) wire to the center terminal block post with one of the 10–32 hex nuts.

7. Connect line 1 (black) and line 2 (red) wires to the outer terminal block posts with 10-32 hex nuts.

8. Securely tighten hex nuts.9. Replace terminal block access cover.

A. Terminal blockB. Ground-link screwC. Cord/conduit plateD. Line 2 (red) wire

E. Neutral (white) wireF. Line 1 (black) wireG. Bare (green) ground wire

A. Terminal lugB. SetscrewC. Line 1 (black) wireD. Neutral (white) wireE. Line 2 (red) wire

A

B

C

D

EF

G

A

B

C D E

Wire Awg Torque

8 gauge copper 25 lbs-in. (2.8 N-m)

6 gauge aluminum 35 lbs-in. (4.0 N-m)

A. 10–32 hex nutB. Line 1 (black)C. Bare (green) ground wireD. Ground-link screw

E. Neutral (white) wireF. Line 2 (red)G. Terminal lug

B

AG

EC

D

F

Page 13: INSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC · PDF fileINSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC RANGE WITH ... If installing a range hood or microwave hood ... *The NEC

13

3-wire connection: Direct Wire

Use this method only if local codes permit connecting ground conductor to neutral supply wire.1. Pull the conduit through the hole and conduit plate on bottom

of range. Allow enough slack to easily attach the wiring to the terminal block.

2. Attach terminal lugs to line 1 (black), bare (green) ground, and line 2 (red) wires. Loosen (do not remove) the setscrew on the front of the terminal lug and insert exposed wire end through bottom of terminal lugs. Securely tighten setscrew to XX lbs-in. torque. See Bare Wire Torque Specifications chart.

Bare Wire Torque SpecificationsAttaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)

3. Use ³⁄₈" nut driver to connect the bare (green) ground wire to the center terminal block post with one of the 10–32 hex nuts.

4. Connect line 1 (black) and line 2 (red) wires to the outer terminal block posts with 10-32 hex nuts.

5. Securely tighten hex nuts.6. Replace terminal block access cover.

Verify Anti-Tip Bracket Location1. Make sure the anti-tip bracket is installed.

■ Look for the anti-tip bracket securely attached to floor or wall.

2. If not direct wired, plug power cord into appropriate outlet.3. Slide range back so rear range foot is engaged with anti-tip

bracket. Check that the flexible conduit or power supply cord is not bent.

A. Terminal blockB. Ground-link screwC. Cord/conduit plate

D. Line 2 (red) wireE. Bare (green) ground wireF. Line 1 (black) wire

A. Terminal lugB. SetscrewC. Line 1 (black) wireD. Bare (green) ground wireE. Line 2 (red) wire

A

B

C

D

EF

A

B

C D E

Wire Awg Torque

8 gauge copper 25 lbs-in. (2.8 N-m)

6 gauge aluminum 35 lbs-in. (4.0 N-m)

A. 10–32 hex nutB. Line 1 (black)C. Ground-link screw

D. Bare (green) ground wireE. Line 2 (red)F. Terminal lug

B

FA

E

DC

Page 14: INSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC · PDF fileINSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC RANGE WITH ... If installing a range hood or microwave hood ... *The NEC

14

Level Range1. Place oven rack in oven. 2. Place level on oven rack and check levelness of range, first

side to side; then front to back.

3. If range is not level, pull range forward until rear leveling leg is removed from the anti-tip bracket.

4. Use wrench to adjust leveling legs up or down until range is level. Push range back into position.

5. Check that rear leveling leg is engaged in anti-tip bracket.NOTE: Range must be level for satisfactory baking performance.

Complete Installation1. Check that all parts are now installed. If there is an extra part,

go back through the steps to see which step was skipped.2. Check that you have all of your tools.3. Dispose of/recycle all packaging materials.4. Check that the range is level. See “Level Range.”5. Use a mild solution of liquid household cleaner and warm

water to remove waxy residue caused by shipping material. Dry thoroughly with a soft cloth. For more information, read the “Range Care” section of the Use and Care Guide.

6. Read the range Use and Care Guide.7. Turn power on. Turn on surface burners and oven. See the

Use and Care Guide for specific instruction on range operation.

If range does not operate, check the following:■ Household fuse is intact and tight; or circuit breaker has not

tripped.

■ Range is plugged into an outlet.

■ Electrical supply is connected.

■ See “Troubleshooting” in the Use and Care Guide.

When the range has been on for 5 minutes, check for heat. If range is cold, turn off the range and contact a qualified technician.

Page 15: INSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC · PDF fileINSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC RANGE WITH ... If installing a range hood or microwave hood ... *The NEC

15

Moving the Range

When moving range, slide range onto cardboard or hardboard to avoid damaging the floor covering.If removing the range is necessary for cleaning or maintenance:

For power supply cord-connected ranges:1. Slide range forward.2. Unplug the power supply cord.3. Complete cleaning or maintenance.4. Plug in power supply cord.5. To check that anti-tip bracket is installed, use a flashlight and

look underneath the bottom of the range:■ Look for the anti-tip bracket securely attached to floor or

wall.

■ Slide range back so rear range foot is under anti-tip bracket.

6. Check that range is level.

For direct-wired ranges:

1. Disconnect power.2. Slide range forward.3. Complete cleaning or maintenance.4. To check that anti-tip bracket is installed, use a flashlight and

look underneath the bottom of the range:■ Look for the anti-tip bracket securely attached to floor or

wall.

■ Slide range back so rear range foot is under anti-tip bracket.

5. Check that range is level.6. Reconnect power.

WARNING

Tip Over Hazard

A child or adult can tip the range and be killed.

Connect anti-tip bracket to rear range foot.

Reconnect the anti-tip bracket, if the range is moved.

Failure to follow these instructions can result in death or serious burns to children and adults.

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

Page 16: INSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC · PDF fileINSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC RANGE WITH ... If installing a range hood or microwave hood ... *The NEC

W10270322A© 2009. Whirlpool Corporation.All rights reserved.

5/09Printed in U.S.A.