Page 1: INSTALLATION AND OPERATION MANUAL Manual_P-100.pdf · Water Hero P -100 is plumbed into a water supply line. Improper installation can cause leaks. Ensure installation is completed

INSTALLATIONANDOPERATIONMANUAL

Page 2: INSTALLATION AND OPERATION MANUAL Manual_P-100.pdf · Water Hero P -100 is plumbed into a water supply line. Improper installation can cause leaks. Ensure installation is completed

MainController WaterMeter,SensorCap&Unions

SensorCable[~6footlength]

MotorizedBallValve[~6footcordlength]

5VPowerSupply[~6footcordlength]

1

ThankyouforpurchasingtheWaterHeroP-100,whichofferswhole-buildingleakdetectionandwaterconservationmonitoring.Thisboxcontains:

WaterHeroP-100

Page 3: INSTALLATION AND OPERATION MANUAL Manual_P-100.pdf · Water Hero P -100 is plumbed into a water supply line. Improper installation can cause leaks. Ensure installation is completed

Warning

2

WaterHeroP-100isplumbedintoawatersupplyline.Improperinstallationcancauseleaks.Ensureinstallationiscompletedbyalicensedplumberandabidesbythefollowingguidelines:• Inaccordancewithstate/localbuilding

codes• Wearpersonalprotectiveequipment

wheninstallingtheWaterHeroP-100• DonotopentheWaterHeroMain

ControllerorSensorCap.Ifyouhavetrouble,contactWaterHerosupport

• UsetheWaterHeroonlywhereitcomplieswithapplicablerulesandregulations

• InstalltheWaterHeroP-100Systemindoorswhereitwillnotbeexposedtodirectsunlight,waterorextremelyloworhightemperatures.Noexposuretowater.RH<90%;Temp0to140F

• AccuracyoftheWaterHeroP-100isdependentonflowrate– accuracyistypicallywithin10%

Terms&Conditions

AllWaterHerotermsandconditions,privacypoliciesandwarrantypoliciescanbefoundontheWaterHerowebsitewww.waterheroinc.com/legal

Contactus

Forinstallationandtechnicalsupportquestions,reachouttousat:[email protected]

Page 4: INSTALLATION AND OPERATION MANUAL Manual_P-100.pdf · Water Hero P -100 is plumbed into a water supply line. Improper installation can cause leaks. Ensure installation is completed

3

Page 5: INSTALLATION AND OPERATION MANUAL Manual_P-100.pdf · Water Hero P -100 is plumbed into a water supply line. Improper installation can cause leaks. Ensure installation is completed

Start-upGuide

4

Page 6: INSTALLATION AND OPERATION MANUAL Manual_P-100.pdf · Water Hero P -100 is plumbed into a water supply line. Improper installation can cause leaks. Ensure installation is completed

ConnectyourWaterHero

5

1. PlaceWaterHeroneardesiredinstallationsite2. ConnectSensorCablefromMainControllertoSensorCap3. ConnectyourValvePowerCordtotheMainController4. EnsurethatyourWi-FiAccessPointisonandoperating5. PlugPowerSupplyintoMainControllerandthenintooutlet

HouseholdPower

SensorCable

ValvePowerCord

Wi-FiAccessPointisoperating

Page 7: INSTALLATION AND OPERATION MANUAL Manual_P-100.pdf · Water Hero P -100 is plumbed into a water supply line. Improper installation can cause leaks. Ensure installation is completed

6

1. Usingyourdevice(i.e.computer,laptop,ormobiledevice),openawebbrowser.EnterURLmy.waterheroinc.com andselect“Createanaccount”

2. Enteryoure-mailaddressanddesiredpassword.Rememberyouraccounte-mailandpassword

3. Select“CreateAccount”

CreateaWaterHeroAccount

Page 8: INSTALLATION AND OPERATION MANUAL Manual_P-100.pdf · Water Hero P -100 is plumbed into a water supply line. Improper installation can cause leaks. Ensure installation is completed

7

SensorCable&OtherConnections

*IfYellowlightisnotilluminatedperformaNetworkReset,P.19ofmanual

2. Connectyourdevicetothe“WaterHeroAP”network

3. Openaninternetbrowser(e.g.InternetExplorer,Chrome)andenterURL“http://192.168.1.1”tobedirectedtotheDeviceConfigurationpage

1. TurntheMainControllertoitsside;ensuretheyellowlightisonandthegreenlightisblinking*

AccesstheDeviceConfigurationpage

Page 9: INSTALLATION AND OPERATION MANUAL Manual_P-100.pdf · Water Hero P -100 is plumbed into a water supply line. Improper installation can cause leaks. Ensure installation is completed

8

*Use“ManualInput”onlyif“DiscoveredNetworks”dropdownmenuisfull**TextEntryFieldsaresensitivetospelling,capitalsandspaces

1. Clickthedropdownmenuunder“DiscoveredNetworks”.Ifavailable,selectthe(SSID)Wi-FiNetworkthatyou’dlikeWaterHerotoconnectwith.Nexttoeachdiscoverednetworkisanindicationofsignalstrength- theclosertozero,thestrongerthesignal.Ifyournetworkisnotshownselect“None”andmanuallyinputyourSSIDandwebencryption(onyourrouter)*

2. EnteryourWi-Finetworkpassword**3. Entertheaccounte-mailaddress(fromP.6)**4. Onceallinformationisentered,press“Add”

EnterWi-FiNetworkInformation

Page 10: INSTALLATION AND OPERATION MANUAL Manual_P-100.pdf · Water Hero P -100 is plumbed into a water supply line. Improper installation can cause leaks. Ensure installation is completed

VerifyWaterHeroConnection

*Ifgreenlightnotblinking,conductNetworkResetonP.20ofmanual9

MainController[SideView]

1. Uponsuccessfulconnection,redlightwillblink,yellowlightwillblinkandthengreenlightwillremainblinking*

2. OpenabrowserandenterURLmy.waterheroinc.com3. Enteraccountusernameandpasswordandpresslogintoview

yourdeviceonline

SensorCable&OtherConnections

Page 11: INSTALLATION AND OPERATION MANUAL Manual_P-100.pdf · Water Hero P -100 is plumbed into a water supply line. Improper installation can cause leaks. Ensure installation is completed

PrepareforinstallationofWaterHeroP-100

10

• TheWaterHeroP-100canbeinstalledinahorizontalorverticalorientation

• Motorized BallValveshouldbeinstalledupstreamfromthemeter

• WaterHeroP-100MUSTbeinstalleddownstreamoffiresuppressionsystems andisrecommendedforinstallationdownstreamofirrigationandwatersoftenersystems

• WaterHeroshouldbeinstalledindoors,protectedfromtheelements,freezingtemperaturesorexcessivehumidity

• Unit’sMainControllerispoweredbya5Vpowersupplyandshouldbelocatedwithaccesstoa2.4GHzWi-Ficonnection*

• UnscrewSensorCapanddisconnectMotorizedBallValvefromMainControllerbeforeplumbinginWaterHero

*Wi-Finetworkscannotbebehindacorporatefirewallorsign-inpage

Page 12: INSTALLATION AND OPERATION MANUAL Manual_P-100.pdf · Water Hero P -100 is plumbed into a water supply line. Improper installation can cause leaks. Ensure installation is completed

PlumbWaterHeroMeter&MotorizedBallValveintopipe- reconnectcordsandassemblywhencomplete;verifyconnection(blinkinggreenlight)*

MainWaterSupply

Streetside

MotorizedBallValve

WARNING:WaterHeroP-100MUSTbeplumbedafter(downstreamof)firesuppressionsystems.

WaterMeter,SensorCap&Unions

MainController

Inbuilding

11*PressReboot(Button1,P.19)ifgreenlightisnotblinkingafterreconnection

Page 13: INSTALLATION AND OPERATION MANUAL Manual_P-100.pdf · Water Hero P -100 is plumbed into a water supply line. Improper installation can cause leaks. Ensure installation is completed

Features&Functionality

12

Page 14: INSTALLATION AND OPERATION MANUAL Manual_P-100.pdf · Water Hero P -100 is plumbed into a water supply line. Improper installation can cause leaks. Ensure installation is completed

13

MyDevices

Logintoyouraccountatmy.waterheroinc.com andyouwillbepresentedthe“MyDevices”tab.ThistabshowsallWaterHerodevicesregisteredtotheaccount.Italsoshowstotalwaterflowamountforeachdevicelistedandtheambienttemperatureatthemetersensor.

ClickontheDeviceNametoaccessadashboardthatshowsreal-timeinformation

Page 15: INSTALLATION AND OPERATION MANUAL Manual_P-100.pdf · Water Hero P -100 is plumbed into a water supply line. Improper installation can cause leaks. Ensure installation is completed

*Home/awaymodealertsandshut-offscanbeadjustedinSettings14

Dashboard

Leakdetectionmode

selector*

Gaugedisplaysrealtimeflowinformation

RemoteValveOperationSelector

AmbientairtemperatureatWater

HeroSensor

Hourlywaterusagedata

Page 16: INSTALLATION AND OPERATION MANUAL Manual_P-100.pdf · Water Hero P -100 is plumbed into a water supply line. Improper installation can cause leaks. Ensure installation is completed

15

Utilities

“MeasureFlow”isastopwatchfeaturethatallowsusertoviewtheamountofwaterthathasbeenusedoveraperiodoftime

“TimedMeasurement”allowsusertofindouthowmuchwaterwasusedduringaspecificperiodoftime

Page 17: INSTALLATION AND OPERATION MANUAL Manual_P-100.pdf · Water Hero P -100 is plumbed into a water supply line. Improper installation can cause leaks. Ensure installation is completed

16

Settings

HomeandAwayModepanelsallowusertosetlimitsafterwhichalertsandautomaticshut-offaretriggered

Temperaturealertspanelallowusertosetlowandhightemperaturewarnings.Temperatureextremescouldindicatefrozenpipesorafire

Notificationspanelallowsusertoselectmethodbywhichwarningsandalertsaresent

Page 18: INSTALLATION AND OPERATION MANUAL Manual_P-100.pdf · Water Hero P -100 is plumbed into a water supply line. Improper installation can cause leaks. Ensure installation is completed

17

Preferences

Enablesswitchingbetweenimperialandmetricunitsofmeasurementforvolumeandtemperature

Indicatese-mail,nameandphonenumberforyouraccount

Page 19: INSTALLATION AND OPERATION MANUAL Manual_P-100.pdf · Water Hero P -100 is plumbed into a water supply line. Improper installation can cause leaks. Ensure installation is completed

AdvancedSetup

18

Page 20: INSTALLATION AND OPERATION MANUAL Manual_P-100.pdf · Water Hero P -100 is plumbed into a water supply line. Improper installation can cause leaks. Ensure installation is completed

19

Diagnostics

WaterHeroAccessPointMode[greenblinking;yellowsolid]

NormalOperation[greenblinking]

Sensorcablenotconnected[redblinking]

1 Reboot

2 ValveOpen/Close

3 NetworkReset(SeeP.20)

MainController[SideView]

Buttons

LEDs

Buttons

SensorCable&OtherConnections

LEDs

1 2 3

Page 21: INSTALLATION AND OPERATION MANUAL Manual_P-100.pdf · Water Hero P -100 is plumbed into a water supply line. Improper installation can cause leaks. Ensure installation is completed

20

NetworkReset

1. PressandreleaseButton1;allLEDsilluminate2. WhileallLEDsareilluminated,pressandholdButton3until

theredLEDturnsoff3. Afterapproximately15seconds,yellowLEDwillilluminate

andthegreenLEDwillblink;WaterHerowillbeinAccessPointmode*

4. FollowdirectionsonP.8toconnectWaterHerotonetwork

Performanetworkresettoconnectthedevicetoanewwirelessnetworkormodifye-mailaccount*

MainController[SideView]

Buttons

SensorCable&OtherConnections

LEDs

*Duetobatteryback-upunpluggingthedevicewillnotresetthedevice

1 2 3

Page 22: INSTALLATION AND OPERATION MANUAL Manual_P-100.pdf · Water Hero P -100 is plumbed into a water supply line. Improper installation can cause leaks. Ensure installation is completed

2017WaterHero,Inc