Important variables
Air:
Water:
Conversion:
- Use ASHRAE tables I gave you:
- You can fine them online http://www.engineeringtoolbox.com/unit-converter-d_185.html
(be careful, not all online converters are correct)
![Page 2: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/2.jpg)
Objective
• Finish cooling & energy storage systems
• Define Building Zones
• Learn about air handling and water distribution systems
![Page 3: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/3.jpg)
Absorption Cycle
• Water is typical refrigerant• Strong vacuum - ~0.116 psi or 0.0008 MPa• Boiling point of water?
• Differences from vapor compression• No compressor
• Chemical (e.g. LiBr - hygroscopic) – Absorbs water vapor turns it into a liquid
– Regenerated by removing water
• Requires heat
![Page 4: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/4.jpg)
Absorption CycleStrong vacuum Refrigerant: water Absorber: lithium bromide
Replace compressor
![Page 5: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/5.jpg)
![Page 6: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/6.jpg)
Evaporative Cooling
• Wet media/water spray – direct• Raise absolute humidity, lowers temperature of
conditioned air
• Cooling tower – indirect• Cools through a heat exchanger• Lowers temperature, does not affect absolute
humidity• Can directly cool air in cold weather
![Page 7: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/7.jpg)
Evaporative Cooling
![Page 8: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/8.jpg)
Cooling
Evaporative cooling Compressor Cooling Sorption cooling
DX machine Chiller
Air CooledCondenser
Water CooledCondenser
Convert Cooling machine (DX machine) to heat pumps
Evaporative Chiller
![Page 9: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/9.jpg)
Daily distribution of cooling load
![Page 10: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/10.jpg)
Thermal Storage
• Make ice/chilled water at times of low demand or low energy prices
• Store water in insulated container
• Can be used to reduce overall demand
• Water can be used as secondary water source for fire protection
• Ice/snow
![Page 11: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/11.jpg)
Thermal Storage
![Page 12: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/12.jpg)
Thermal storage
![Page 13: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/13.jpg)
Ventilation Air-flow in Buildings
http://www.epa.gov/iaq/largebldgs/i-beam_html/qref_01_03.htm
![Page 14: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/14.jpg)
Zones In building
• How to define the zone in building
• Based on cooling/heating load requirement
• Based on ventilation requirement
• Based on use of buildings
– different apartments deferent zones
![Page 15: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/15.jpg)
Air Handling Units (AHU) Control of air Systems
• Provide conditioned air• Heating, cooling, humidification, dehumidification
• Ventilation• Provide fresh air, remove contaminated air
![Page 16: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/16.jpg)
Air Handling Unit (AHU)
Compressorand Condenser
Roof top AHU
Gas/Electric Heater
to building
Fan
air from building
fresh air
Evaporator
filtermixing
hotwater
coolwater
Return fan
Supply fan
flow control dampers
AHU
Fresh air
AHU schematic
Outdoor air To room
Exhaust From room
![Page 17: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/17.jpg)
Air Handling Units (AHS)
Equipment For AHU:• Fans• Cooling and heating coils• Combustion heat exchangers• Filtration• Dampers, controls, mixing valves• Humidification: steam/spray• Dehumidification: cooling coil/desiccant• Noise control
![Page 18: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/18.jpg)
Control of air Systems
• Vary temperature, constant flow
• Constant temperature, vary flow
• Vary temperature, vary flow
![Page 19: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/19.jpg)
How does a residential thermostat work?
A. Calculates difference between actual temperature and required temperature and adjusts furnace/AC output accordingly
B. Measures temperature continuously and turns equipment on and off when temperature is different from set point temperature
C. Measures temperature continuously and turns equipment on and off when temperature is outside of specified bounds
D. Calculates difference between actual temperature and required temperature and adjusts the velocity of the fan (flow-rate) accordingly
![Page 20: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/20.jpg)
Constant Temperature, Variable Volume
• On-off systems• Residential and small commercial• Vary volume by turning system on and off
![Page 21: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/21.jpg)
Constant Air Volume
• Single zone constant air volume• Fan always runs
• Vary temperature of air in response to space thermostat
• Single zone constant air volume with reheat• Often used for precise humidity control
• Multizone constant air volume with reheat• Good humidity control, flexible
• Not very efficient
![Page 22: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/22.jpg)
Constant Volume – temperature control
• Proportional control or Proportional Integral control • Thermostat measure: ΔT = T set point – T zone air • Send the signal to the valve of cooling/heating coil
![Page 23: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/23.jpg)
Multizone constant air volume with reheat
55°F
62°F 55°F
Require less
cooling
![Page 24: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/24.jpg)
Variable Air Volume
• Single zone VAV• Varies air flow based on room thermostat
• Multizone VAV• Central chilled air supply
• Zone thermostats control flow to each zone
• Can also use reheat• Still need to provide adequate air flow for ventilation and
for comfort
• Smaller energy penalty than CAV
![Page 25: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/25.jpg)
VAV terminal
![Page 26: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/26.jpg)
Multizone VAV
55°F
55°F 55°F
Vary the flow
![Page 27: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/27.jpg)
Dual-Duct Systems• Can be VAV or CAV• Two plenums with chilled air and heated air• Zone thermostats control ratio Separate duct
for each zone
![Page 28: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/28.jpg)
Reading Assignment
Tao and Janis
Chapter 3 Sections: 3.4.1- 3.4.16 (including 3.4.16)
Chapter 6 (from 6.1 to 6.7)
![Page 29: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/29.jpg)
Homework Assignment 4Table 1 Results of cooling load calculation and required amount of fresh air for ventilation
Zone 1Zone 2 Zone 3 Whole
building
Sensible cooling load for zone Time when the max cooling load appear
41000 Btu/hat 4 PM
45000 Btu/hat 6 PM
27000 Btu/hat 8 AM 92000 Btu/h
at 6 PMSensible cooling load for critical hour for whole building (6 PM)
37000 Btu/hat 6 PM
45000 Btu/hat 6 PM
9000 Btu/hat 6 PM
Latent cooling load (internal sources + infiltration)
5400 Btu/h 5200 Btu/h 5400 Btu/h 16000 Btu/h
Required amount of fresh air based on number of occupants
240 CFM(12 occupants)
520 CFM(26 occupants)
240 CFM(12 occupants)
1000 CFM(50 occupants)
![Page 30: Important variables Air: Water: Conversion: - Use ASHRAE tables I gave you: - You can fine them online .](https://reader030.fdocuments.us/reader030/viewer/2022032803/56649e315503460f94b22db5/html5/thumbnails/30.jpg)
Homework Assignment 4
• Supply air 55°F
• Recirculation air 76°F
• Fresh air (Dallas, TX) DBT=102°F