Set the device is used in a diver rescue equipment and is designed to provide breathing diver when leaving the submarine in accordance with the 'exit from emergency personnel submarine ", can be used as a means of temporary life support personnel in both compartments of the submarine, and in APU (SWR The total duration of the IDA-59M when leaving the submarine - at least 150 minutes. The unit is operable when the cylinder pressure from 19.6 to 3.0 MPa. Capacity oxygen tank - 1 liter. Cylinders AGK - 1 liter. Used in the tank mixture AGK - 25% of the oxygen-nitrogen-helium (Trimix). Capacity breathing bag - no more than 9 liters. Mark used a chemical - About TU-3 6-16-26. Mass of the substance O-3 - no more than 1800 Weight unfilled system (without a mask) - no more than 10.5 kg. Weight mask - not more than 400 g Overall dimensions of the unit, laid in a bag - no more 500h370h180 mm. Designated lifetime - not less than 10 years.

description

good inf

Transcript of IDA 59

Page 1: IDA 59

Set the device is used in a diver rescue equipment and is designed to provide breathing diver when leaving the submarine in accordance with the 'exit from emergency personnel submarine ", can be used as a means of temporary life support personnel in both compartments of the submarine, and in APU (SWR

The total duration of the IDA-59M when leaving the submarine - at least 150 minutes.

The unit is operable when the cylinder pressure from 19.6 to 3.0 MPa.

Capacity oxygen tank - 1 liter.

Cylinders AGK - 1 liter.

Used in the tank mixture AGK - 25% of the oxygen-nitrogen-helium (Trimix).

Capacity breathing bag - no more than 9 liters.

Mark used a chemical - About TU-3 6-16-26.

Mass of the substance O-3 - no more than 1800

Weight unfilled system (without a mask) - no more than 10.5 kg.

Weight mask - not more than 400 g

Overall dimensions of the unit, laid in a bag - no more 500h370h180 mm.

Designated lifetime - not less than 10 years.

Page 2: IDA 59

Bib - for accommodating the component parts of the apparatus. He has:

- Pockets for bottles;

- Pocket to accommodate regenerative box apparatus;

- Fastening strap breathing bag;

- Suspension system for attaching the device to the divers, consisting of a lap belt and crotch strap;

Breathing bag - ring-shaped reservoir to stock the gas mixture used for breathing. Inside the bag is

placed hose connecting the breathing machine with a nipple for connection to a tee reducer cylinder

AGK. Inside the bag also has bellows inhalation and exhalation, respectively, which are connected to

the inhalation and exhalation tubes located outside the breathing bag;

Safety valve - maintains the required pressure in the breathing bag. Resistance of the valve is

adjusted by turning the adjusting screw;

Machine breathing - for automatic feeding of the gas mixture from the cylinder into the breathing

bag AGC with a deficiency of volume mixture inspiratory volume and automatically maintain the

mixture at a pressure equalizing cavity pressure breathing bag with the environment;

Box valve - permits breathing apparatus with a gas mixture of air or from the surrounding

atmosphere. Switching valve chest breathing atmospheric air or on the machine by turning the handle

all the way in the direction of the arrows;

Regenerative box - is designed to clean the exhaled gas from the contained CO 2 enrichment and

O 2 breathing gas mixture;

Reducer oxygen cylinder - direct action with manual restart. The inclusion of the gear is done by

turning the handle.The gearbox is equipped with fusible link to protect the cylinder from damage

during heating;

Switch - to automatically change the oxygen flow rate, depending on the depth of the diver;

Reducer cylinder AGK - for reducing the high pressure gas mixture coming from the

tank. Structurally cylinder gear reducer AGC performed similarly to an oxygen cylinder, except for the

presence of holes in the lid, which serves to communicate nadmembrannoy the gear unit with the

environment.

Tee - for connection to the pin via a screw gear and oxygen to a breathing machine cylinder, as well

as to connect an optional helium balloon.

Page 3: IDA 59

Mask - Respiratory protection and vision diver from the environment.

Significantly longer lifetime compared with the device of the earlier work.

Fusible safety valves on cylinders, thus preventing degradation in case of overheating.

The use of more convenient government unit.

On the basis of the apparatus IDA-59M produced his training version IDA-59-U-M is designed for the

study of the structure and personnel training surfacing submarine.