ELECTRICAL MODELING OF MAIN INJECTOR SEXTUPOLE MAGNETS Si Fang February 1, 1995 1. Introduction The electrical rnodels for the main injector sextupole magnet is obtained based on three terminal device impedance matrix measurement. The measurement data are analyzed and curve fitted into their equivalent circuits by using circuit simulation program Spice. 2. Electrical Measurement The sextupole magnet is a three-terminal device. Fig 1 depicts the sextupole magnet three-terminal representation. Terminal 1 and 2 are the coil bus terminals and terminal 3 is the magnet case ground. The electrical characteristics of the magnet at non saturation can be described by its admittance matrix. The equations for this Sextupole Magnet three-terminal device network can be written as Fig 1 Sextupole Three-Terminal Representation Yll Y12 Y13 Y21 Y22 Y23 Y31 Y32 Y33 I[ Vl v2 v3 I (1) The 3x3 matrix on the right hand side of Eqn. (1) is called shorted circuit admittance matrix of the considered three-terminal sextupole magnet. The elements in the shorted circuit admittance matrix are frequency dependent variables. The way to measure this 3x3 matrix elements is depicts in figure 2. The excitation source used here is a high power frequency generator (Elgar Model 500) that can output current up to 5 amps. the output voltage can be adjusted from 0 to 1.50 Vrms, and the frequency can be varied from 10 Hz to 1OKHz. A Tektronix current probe, which has the bandwidth of DC to 50 MHz, was used for current measurement. Both voltage and current as well as phase shifted between 1 v2 Z32= T37 = 13 Fig 2 Admittance Matrix Measurement

Transcript of I[beamdocs.fnal.gov/AD/DocDB/0001/000130/002/MI-0135.pdf · Fig 1 Sextupole Three-Terminal...

ELECTRICAL MODELING OF MAIN INJECTOR SEXTUPOLE MAGNETS Si Fang

February 1, 1995

1. Introduction

The electrical rnodels for the main injector sextupole magnet is obtained based on three terminal device impedance matrix measurement. The measurement data are analyzed and curve fitted into their equivalent circuits by using circuit simulation program Spice.

2. Electrical Measurement

The sextupole magnet is a three-terminal device. Fig 1 depicts the sextupole magnet three-terminal representation. Terminal 1 and 2 are the coil bus terminals and terminal 3 is the magnet case ground. The electrical characteristics of the magnet at non saturation can be described by its admittance matrix. The equations for this

Sextupole Magnet

three-terminal device network can be written as

Fig 1 Sextupole Three-Terminal Representation

Yll Y12 Y13

Y21 Y22 Y23

Y31 Y32 Y33 I[ Vl

v2

v3 I (1)

The 3x3 matrix on the right hand side of Eqn. (1) is called shorted circuit admittance matrix of the considered three-terminal sextupole magnet. The elements in the shorted circuit admittance matrix are frequency dependent variables. The way to measure this 3x3 matrix elements is depicts in figure 2. The excitation source used here is a high power frequency generator (Elgar Model 500) that can output current up to 5 amps. the output voltage can be adjusted from 0 to 1.50 Vrms, and the frequency can be varied from 10 Hz to 1OKHz. A Tektronix current probe, which has the bandwidth of DC to 50 MHz, was used for current measurement. Both voltage and current as well as phase shifted between

1 v2 Z32= T37 = 13

Fig 2 Admittance Matrix Measurement

voltage and current were measured by Tektronix scope. Ratio of peak to peak value of current to voltage was obtained for the shorted circuit admittance at the frequency of interest. Scope measurement for voltage and current made sure the signals being measured were not distorted.

3. Measurement Data Fitting

DC Resistance of the coil bus is measured at 18 “C. The resistance then is scaled to the resistance at 40 “C by using the formula:

R(40”C)=R(18°C)~[1+0.004/o C(4O”C-18”C)] (2)

Coil Impedance measurement is performed by Zr 1, 222, 212, 221. ZI 1 and 222 are equal both in magnitude and phase for the frequency up to 10 KHz. 212 and 221 are also the same both in magnitude and phase. Zll and Z12 are the same in magnitude but 180” out of phase because the reverse direction of the current. This implies the Sextupole is symmetrical since impedance looking into both coil bus terminals is equal.

By analyzing the coil impedance measurement data Zlt and 222. The data can be represented by straight-line asymptotes as shown in Fig 3. The bus DC resistance has effect on coil impedance at very low frequency(c< 10 Hz), therefore it is not shown in the impedance asymptote representation here. The coil bus impedance is inductive at the frequency between 10 Hz and Fl , F2 and F3 because the slope of the magnitude asymptote line is 20 dB/decade and the phase is 90”. The coil bus becomes small resistive at the frequency between Fl and F2, and above F3. In the other word, the inductance of the coil decreases as the frequency increases.

A’ IZI dB

ZOdB/decade

F3

/

10 Frequency (Hz)

IOK

Fig 3 Coil Impedance Data Asymptote Representation

R3 R2

Rl I mLlr L2

w

Fl- ;i2 FZ=Ro F3-5

Z-T-L2 Z*Tr*Lo 2rnCLl

where Ll*L2 R2bR3 Lc=LltL2 R"=R2+R3

An electrical circuit shown in Fig 4 can be used to represent the straight-line asymptote characteristics in Fig 3. The L Fig 4 Circuit For Fig 3 Straight-Line Asymptote -- comer frequency break points are approximately given by the formula in figure 4.

Bus Capacitance Measurement is obtained by 213, 231, 223, 232, and 233. 233 measures the total bus to ground capacitance. 213 and 231 measures the capacitance between terminal 1 and ground while

terminal 2 is shorted to ground. Similarly, 223 and 232 measures the capacitance between terminal 2

2

and ground while terminal 1 is grounded. The 213, 231, 223, 232, and 233 are capacitance measurement because the slope of the measurement data is -2OdB/decade in the magnitude plot. The capacitance is determined by the following formula

(3)

wherefis the excitation frequency in Hz and 2 is the impedance in ohms.

4. Sextupole Electrical Model

The impedance matrix measurement data for the sextupole are given in Appendix A. The DC resistance is measured at 18 “C and the value is 15.62 n-&J. The resistance at 40 “C is calculated to be 17 & by using Eqn (2). Rl in Fig 4 is the DC resistance.

Sextupole

14700 Hi!

10 100 1000 10000

Frequency (Hz)

Fig 5 Straight Line Asymptote Representation of Sextupole Coil Impedance

Coil Impedance measurement is obtained by Zt 1, 222, 212, 221. They all have the same magnitude as function of frequency. Figure 5 shows Zll measurement data where the data can be represented by straight line asymptotes. The parameters in the circuit (Fig 4) can be determined according to the data. Referring to Fig 5, the corner frequency break points, the total coil inductance at low frequency (10 Hz), the inductance at high frequency (1OKHz) are obtained as:

F1=640 Hz F2=1300 Hz F3=14700 Hz

Total Inductance @ 10 Hz: LT= 1 I I -log-l[~] = 2.8 mH where lZlll= -15.1 dB

Wf

3

Inductance @ 5 KHz: LI = J- log-’ [- I I 211

I = 1*3 mH where IZlll= 32.2 dB

2M 20

The value of the circuit elements can be calculated since the total coil inductance, inductance at the frequency of F2 c f < F3 , and the corner frequency break points are known.

L2 Inductance: L2= LT--1 = 1.5 Id3

R2: R2=2.n.Fl-L2 =6Q

R3: R4=2.n:-F3.L1 = 120R

Bus Capacitance is measured by Zts, Zst, 225, 252, and Zss. The total bus to magnet case ground capacitance (CT) is measured by Z55. Z15 and Z51 measures the capacitance (Cl) between terminal 1 and ground while terminal 2 is shorted to ground. Similarly, 225 and 252 measures the capacitance (0) between terminal 2 and ground while terminal 1 is grounded.

Total Bus to Ground Capacitance: 1

cT = 2. x. f . pssj = 3.8 nF

Terminal 1 to Ground Capacitance: CI = 1

2.n.f ./q = lo9 nF Or

1 c1= 2.7c.f.p5,1 = 1-9nF

Terminal 2 to Ground Capacitance: C2 = 1

2.n.f +4 = la9 nF Or

1 c2 = 2. x. f . lzs21 = la9 nF

The sextupole magnet electrical model is shown in Fig 6. The simulation results are given in Appendix A. The model matches the measurement data up to 10 KHz.

R3 R2 1 w

120 n 61-i

0 Rl pp)q-) Ll m LZ 0 I - a . . 17 rnn 1.3 mH 1.5 mH

Fig 6 Main Injector Sextupole Electrical Model

4

5. Conclusion

The sextupole electrical model is obtained based on the impedance matrix measurement. Spice simulation result shows the accuracy of the models. The electrical model can be used as a sub circuit to build a sextupole ring model to study the transient and frequency response of the system.

5

Appendix A- 1

Zll MAGNITUDE PLOT

30

-10

I

100

Frequency (Hz)

Measurement

180

140

8 120

5

s

100

e 80

z N 60

40

20

100

Zll PHASE PLOT

0 Measurement

Simulation

1000

Frequency (Hz)

Main Inj mar Q Sextupole

Appendix A-2

221 MAGNITUDE PLOT

40

30

s a *O

s -2 10

F E

74 0 N

-10

-20

Measurement -

7 10

Frequency (Hz)

221 PHASE PLOT

-20 Measurement

-40

% e

-60

Frequency (Hz)

7 Sextupole Main Injector

Appendix A-3

231 MAGNITUDE PLOT

r 130

0 Measurement

Simulation I:

s 120

5 110

.Z % m E 100

3 90

: I c 80

-1 70

Frequency (Hz)

1000 10000

231 PHASE PLOT

180

0 Measurement

160

140 j ! Simulation

I I I III/- I

G 120

a" - 100

s 2 80

;;: N 60

9

L

40

20

0

Frequency (Hz)

Main Injector 8 Sextupole

Appendix A-4

212 MAGNITUDE PLOT

40

30

g 20

s *z 10

z E

$1 0 N

-10

-20

I-

7F 10

Frequency (Hz)

-20

-40

9 e -60

: -80

2 2 -100

N -120

-140

-160

212 PHASE PLOT

Measurement

-180 i1 I I Illill I I Ill I I I I

10 100 1000

Frequency (Hz)

Main Injector 9 Sextupole

Appendix A-5

222 MAGNITUDE PLOT

40

30

RI

180

160

140

3 120

B - 100

s g 80

3 N 60

40

20

0

I- k c

-

-

-

-

-

/

-

-

L

Frequency (Hz)

222 PHASE PLOT

Measurement

100

Frequency (Hz)

1000 10000

Main Injector 10 Sextupole

Appendix A-6

232 MAGNITUDE PLOT.

130

$ 110 .% Gl Q 100

E

80

Measurement

Frequency (Hz)

1000 10000

180

160

140

9 120

e

s

100

g 80

2 N 60

40

20

232 PHASE PLOT

Measurement

/ I I dli

100

Frequency (Hz)

1000 10000

Main Injector 11 Sextupole

Appendix A-7

213 MAGNITUDE PLOT

140

130

3 120

$ 110

.Z

% m E 100

WI

z 90

80

70

10

c

c

I

r

I I I I

0 Measurement

Simulation / I

\ I P I I I I

\ ~I,1

I /

Frequency (Hz)

180

160

213 PHASE PLOT

Measureme

I? N 60

Frequency (Hz)

:nt

ilain Injector 12 Sextupole

Appendix A-8

223 MAGNITUDE PLOT

130

9

120

” 110

.%

5l m 100

E

a 90

80

70

0 Measurement

c

Frequency (Hz)

180

160

140

,--& 120

g 100

ii f 80

40

223 PHASE PLOT

Measurement

10

Frequency (Hz)

Main Injector 13 Sextupole