HP 5130 EI Switch Series data sheet - CurveSales.com · HP 5130 EI Switch Series comprises Gigabit...

16
Key features • Fixed 10GbE ports for high-speed stacking or uplinks • Support for multiple services • Comprehensive security control policies • Diversified quality of service (QoS) policies • Excellent manageability Product overview HP 5130 EI Switch Series comprises Gigabit Ethernet switches that support static and RIP Layer 3 routing, diversified services, and IPv6 forwarding, as well as provides four 10-Gigabit Ethernet (10GbE) interfaces. Unique Intelligent Resilient Fabric (IRF) technology creates a virtual fabric by managing several switches as one logical device, which increases network resilience, performance, and availability, while reducing operational complexity. These switches provide Gigabit Ethernet access and can be used at the edge of a network or to connect server clusters in small data centers. High availability, simplified management, and comprehensive security control policies are among the key features that distinguish this series. Data sheet HP 5130 EI Switch Series

Transcript of HP 5130 EI Switch Series data sheet - CurveSales.com · HP 5130 EI Switch Series comprises Gigabit...

Key features•Fixed10GbEportsforhigh-speedstackingoruplinks

•Supportformultipleservices

•Comprehensivesecuritycontrolpolicies

•Diversifiedqualityofservice(QoS)policies

•Excellentmanageability

Product overviewHP5130EISwitchSeriescomprisesGigabitEthernetswitchesthatsupportstaticandRIPLayer3routing,diversifiedservices,andIPv6forwarding,aswellasprovidesfour10-GigabitEthernet(10GbE)interfaces.UniqueIntelligentResilientFabric(IRF)technologycreatesavirtualfabricbymanagingseveralswitchesasonelogicaldevice,whichincreasesnetworkresilience,performance,andavailability,whilereducingoperationalcomplexity.TheseswitchesprovideGigabitEthernetaccessandcanbeusedattheedgeofanetworkortoconnectserverclustersinsmalldatacenters.Highavailability,simplifiedmanagement,andcomprehensivesecuritycontrolpoliciesareamongthekeyfeaturesthatdistinguishthisseries.

Data sheet

HP 5130 EI Switch Series

2

Datasheet|HP5130EISwitchSeries

Features and benefitsSoftware-defined networking•OpenFlow

SupportsOpenFlow1.3specificationtoenableSDNbyallowingseparationofthedata(packet forwarding)andcontrol(routingdecision)paths

Quality of service (QoS)•Broadcastcontrol

Allowslimitationofbroadcasttrafficratetocutdownonunwantednetworkbroadcasttraffic

•Advancedclassifier-basedQoS

ClassifiestrafficusingmultiplematchcriteriabasedonLayer2,3,and4information;appliesQoSpoliciessuchassettingprioritylevelandratelimittoselectedtrafficonaport,VLAN,orwholeswitch

•PowerfulQoSfeature

Supportsthefollowingcongestionactions:strictpriority(SP)queuing,weightedroundrobin(WRR),andSP+WRR

•Trafficpolicing

SupportsCommittedAccessRate(CAR)andlinerate

Management•Remoteconfigurationandmanagement

EnablesconfigurationandmanagementthroughasecureWebbrowseroraCLIlocatedonaremotedevice

•Managerandoperatorprivilegelevels

Providesread-only(operator)andreadorwrite(manager)accessonCLIandWebbrowsermanagementinterfaces

•Commandauthorization

LeveragesHWTACACStolinkacustomlistofCLIcommandstoanindividualnetworkadministrator’slogin;alsoprovidesanaudittrail

•SecureWebGUI

Providesasecure,easy-to-usegraphicalinterfaceforconfiguringthemoduleviaHTTPS

•Multipleconfigurationfiles

Storeseasilytotheflashimage

•Completesessionlogging

Providesdetailedinformationforproblemidentificationandresolution

•Remotemonitoring(RMON)

UsesstandardSNMPtomonitoressentialnetworkfunctions;supportsevents,alarm,history,andstatisticsgroupplusaprivatealarmextensiongroup

•IEEE802.1ABLinkLayerDiscoveryProtocol(LLDP)

Advertisesandreceivesmanagementinformationfromadjacentdevicesonanetwork,facilitatingeasymappingbynetworkmanagementapplications

•sFlow®(RFC3176)

ProvidesscalableASIC-basedwirespeednetworkmonitoringandaccountingwithnoimpactonnetworkperformance;thisallowsnetworkoperatorstogatheravarietyofsophisticatednetworkstatisticsandinformationforcapacityplanningandreal-timenetworkmonitoringpurposes

•ManagementVLAN

Segmentstraffictoandfrommanagementinterfaces,includingCLI/Telnet,aWebbrowserinterface,andSNMP

3

Datasheet|HP5130EISwitchSeries

•Remoteintelligentmirroring

Mirrorsingress/egressACL-selectedtrafficfromaswitchportorVLANtoalocalorremoteswitchportanywhereonthenetwork

•DeviceLinkDetectionProtocol(DLDP)

Monitorsacablebetweentwoswitchesandshutsdowntheportsonbothendsifthecableisbroken,whichpreventsnetworkproblemssuchasloops

•IPv6management

Providesfuture-proofnetworkingbecausetheswitchiscapableofbeingmanagedwhethertheattachednetworkisrunningIPv4orIPv6;supportspingv6,tracertv6,Telnetv6,TFTPv6,DNSv6,syslogv6,FTPv6,SNMPv6,DHCPv6,andRADIUSforIPv6

•Troubleshooting

Ingressandegressportmonitoringenablesnetworkproblem-solving;virtualcabletestsprovidevisibilityintocableproblems

•HPIntelligentManagementCenter(IMC)

Integratesfaultmanagement,elementconfiguration,andnetworkmonitoringfromacentralvantagepoint;built-insupportforthird-partydevicesenablesnetworkadministratorstocentrallymanageallnetworkelementswithavarietyofautomatedtasks,includingdiscovery,categorization,baselineconfigurations,andsoftwareimages;thesoftwarealsoprovidesconfigurationcomparisontools,versiontracking,changealerts,andmore

•Networkmanagement

OffersSNMPv1/v2c/v3,withTraps,andRADIUSAuthenticationClientMIB(RFC2618);embeddedHTMLmanagementtoolwithsecureaccess

Connectivity•Auto-MDIX

Adjustsautomaticallyforstraight-throughorcrossovercablesonall10/100/1000ports

•Flowcontrol

ProvidesbackpressureusingstandardIEEE802.3x,reducingcongestioninheavytrafficsituations

•High-densityconnectivity

Providesupto48fixed10/100/1000BASE-TportsinaLayer2/Layer3switch

•IEEE802.3atPoweroverEthernet(PoE+)support

Simplifiesdeploymentanddramaticallyreducesinstallationcostsbyhelpingtoeliminatethetimeandcostinvolvedinsupplyinglocalpowerateachaccesspointlocation

•Ethernetoperations,administrationandmaintenance(OAM)

Detectsdatalinklayerproblemsthatoccurredinthe“lastmile”usingtheIEEE802.3ahOAMstandard;monitorsthestatusofthelinkbetweentwodevices

Performance•Non-blockingarchitecture

Upto176Gbpsnon-blockingswitchingfabricprovideswirespeedswitchingwithupto130.9 millionppsthroughput

•Hardware-basedwirespeedaccesscontrollists(ACLs)

Helpsprovidehighlevelsofsecurityandeaseofadministrationwithoutimpactingnetworkperformancewithafeature-richTCAM-basedACLimplementation

Resiliency and high availability•Separatedataandcontrolpaths

Separatescontrolfromservicesandkeepsserviceprocessingisolated;increasessecurityand performance

•Externalredundantpowersupply

Provideshighreliability

4

Datasheet|HP5130EISwitchSeries

•SmartLink

Allowsunder100msfailoverbetweenlinks

•SpanningTree/PVST+,MSTP,RSTP

Providesredundantlinkswhilepreventingnetworkloops,supportsupto64instancesofMSTP

•IntelligentResilientFabric(IRF)

Createsvirtualresilientswitchingfabrics,wheretwotonineswitchesperformasasingleL2 switchandL3router;switchesdonothavetobeco-locatedandcanbepartofadisaster-recoverysystem;serversorswitchescanbeattachedusingstandardLACPforautomaticloadbalancingandhighavailability;canreduceneedforcomplexprotocolslikeSpanningTreeProtocol,Equal-CostMultipath(ECMP),orVRRP,therebysimplifyingnetworkoperation

Layer 2 switching•16KMACaddresstable

ProvidesaccesstomanyLayer2devices

•VLANsupportandtagging

SupportsIEEE802.1Qwith4,094simultaneousVLANIDs

•IEEE802.1adQinQandselectiveQinQ

IncreasesthescalabilityofanEthernetnetworkbyprovidingahierarchicalstructure;connectsmultipleLANsonahigh-speedcampusormetronetwork

•10GbEportaggregation

Allowsgroupingofportstoincreaseoveralldatathroughputtoaremotedevice

•DeviceLinkDetectionProtocol(DLDP)

Monitorslinkconnectivityandshutsdownportsatbothendsifunidirectionaltrafficisdetected,preventingloopsinSTP-basednetworks

•Jumboframesupport

Improvestheperformanceoflargedatatransfers;supportsframesizeofupto9K-bytes

Layer 3 services•AddressResolutionProtocol(ARP)

DeterminestheMACaddressofanotherIPhostinthesamesubnet;supportsstaticARPs;gratuitousARPallowsdetectionofduplicateIPaddresses;proxyARPallowsnormalARPoperationbetweensubnetsorwhensubnetsareseparatedbyaLayer2network

•DynamicHostConfigurationProtocol(DHCP)

SimplifiesthemanagementoflargeIPnetworks;supportsclient;DHCPRelayenablesDHCPoperationacrosssubnets

•Loopbackinterfaceaddress

Definesanaddressthatcanalwaysbereachable,improvingdiagnosticcapability

•UserDatagramProtocol(UDP)helperfunction

AllowsUDPbroadcaststobedirectedacrossrouterinterfacestospecificIPunicastorsubnetbroadcastaddressesandpreventsserverspoofingforUDPservicessuchasDHCP

•Routemaps

Providesmorecontrolduringrouteredistribution;allowsfilteringandalteringofroutemetrics

Layer 3 routing•StaticIProuting

ProvidesmanuallyconfiguredroutingforbothIPv4andIPv6networks

•RoutingInformationProtocol(RIP)

UsesadistancevectoralgorithmwithUDPpacketsforroutedetermination;supportsRIPv1andRIPv2routing;includesloopprotection

5

Datasheet|HP5130EISwitchSeries

Security•Accesscontrollists(ACLs)

ProvidesIPLayer2toLayer4trafficfiltering;supportsglobalACL,VLANACL,portACL,andIPv6ACL

•IEEE802.1X

Industry-standardmethodofuserauthenticationusinganIEEE802.1XsupplicantontheclientinconjunctionwithaRADIUSserver

•MAC-basedauthentication

ClientisauthenticatedwiththeRADIUSserverbasedontheclient’sMACaddress

•Identity-drivensecurityandaccesscontrol

– Per-userACLs

Permitsordeniesuseraccesstospecificnetworkresourcesbasedonuseridentityandtimeofday,allowingmultipletypesofusersonthesamenetworktoaccessspecificnetworkserviceswithoutriskingnetworksecurityorprovidingunauthorizedaccesstosensitivedata

– AutomaticVLANassignment

AutomaticallyassignsuserstotheappropriateVLANbasedontheiridentities

•Securemanagementaccess

Deliverssecureencryptionofallaccessmethods(CLI,GUI,orMIB)throughSSHv2,SSL,HTTPS,and/orSNMPv3

•SecureFTP/SCP

Allowssecurefiletransfertoandfromtheswitch;protectsagainstunwantedfiledownloadsorunauthorizedcopyingofaswitchconfigurationfile

•GuestVLAN

Providesabrowser-basedenvironmenttoauthenticatedclientsthatissimilartoIEEE802.1X

•Portsecurity

AllowsaccessonlytospecifiedMACaddresses,whichcanbelearnedorspecifiedbythe administrator

•Portisolation

Securesandaddsprivacy,andpreventsmaliciousattackersfromobtaininguserinformation

•STPBPDUportprotection

BlocksBridgeProtocolDataUnits(BPDUs)onportsthatdonotrequireBPDUs,preventingforgedBPDUattacks

•STProotguard

Protectstherootbridgefrommaliciousattacksorconfigurationmistakes

•DHCPprotection

BlocksDHCPpacketsfromunauthorizedDHCPservers,preventingdenial-of-serviceattacks

•IPsourceguard

HelpspreventIPspoofingattacks

•DynamicARPprotection

BlocksARPbroadcastsfromunauthorizedhosts,preventingeavesdroppingortheftofnetworkdata

•RADIUS/HWTACACS

Easesswitchmanagementsecurityadministrationbyusingapasswordauthenticationserver

Convergence•IEEE802.1ABLinkLayerDiscoveryProtocol(LLDP)

FacilitateseasymappingusingnetworkmanagementapplicationswithLLDPautomateddevicediscoveryprotocol

6

Datasheet|HP5130EISwitchSeries

•LLDP-MED

Isastandardextensionthatautomaticallyconfiguresnetworkdevices,includingLLDP-capableIPphones

•LLDP-CDPcompatibility

ReceivesandrecognizesCDPpacketsfromCisco’sIPphonesforseamlessinteroperation

•IEEE802.3atPoweroverEthernet(PoE+)

Providesupto30WperportthatallowssupportofthelatestPoE+-capabledevicessuchasIPphones,wirelessaccesspoints,andsecuritycameras,aswellasanyIEEE802.3af-compliantenddevice;eliminatesthecostofadditionalelectricalcablingandcircuitsthatwouldotherwisebenecessaryinIPphoneandWLANdeployments

•PoEallocations

Supportsmultiplemethods(automatic,IEEE802.3afclass,LLDP-MED,oruser-specified)toallocatePoEpowerformoreefficientenergysavings

•VoiceVLAN

AutomaticallyassignsVLANandpriorityforIPphones,simplifyingnetworkconfigurationand maintenance

•IPmulticastsnooping(data-drivenIGMP)

PreventsfloodingofIPmulticasttraffic

Device support•Pre-standardPoESupport

Detectsandprovidespowertopre-standardPoEdevicessuchaswirelessLANaccesspointsandIPphones

Additional information•GreenITandpower

Improvesenergyefficiencythroughtheuseofthelatestadvancesinsilicondevelopment;shutsoffunusedportsandutilizesvariable-speedfans,reducingenergycosts

•Greeninitiativesupport

ProvidessupportforRoHSandWEEEregulations

•UnifiedHPComwareoperatingsystemwithmodulararchitecture

Providesaneasy-to-enhance-and-extendfeatureset,whichdoesn’trequirewhole-scalechanges;allswitching,routing,andsecurityplatformsleveragetheComwareOS,acommonunifiedmodularoperatingsystem

•EnergyEfficientEthernet(EEE)Support

ReducespowerconsumptioninaccordancewithIEEE802.3az

Warranty and support•LimitedLifetimeWarranty2.0

Advancehardwarereplacementwithnext-business-daydelivery(availableinmostcountries).Seehp.com/networking/warrantysummaryfordurationdetails

•Electronicandtelephonesupport(forLimitedLifetimeWarranty2.0)

Limited24x7telephonesupportisavailablefromHPforthefirst3years;limitedelectronicandbusinesshourstelephonesupportisavailablefromHPfortheentirewarrantyperiod;toreachoursupportcenters,refertohp.com/networking/contact-support;fordetailsonthedurationofsupportprovidedwithyourproductpurchase,refertohp.com/networking/warrantysummary

•Softwarereleases

Tofindsoftwareforyourproduct,refertohp.com/networking/support;fordetailsonthesoftwarereleasesavailablewithyourproductpurchase,refertohp.com/networking/warrantysummary

7

Datasheet|HP5130EISwitchSeries

HP 5130 EI Switch SeriesSpecifications

HP 5130-24G-4SFP+ EI Switch (JG932A) HP 5130-24G-SFP-4SFP+ EI Switch (JG933A)

HP 5130-48G-4SFP+ EI Switch (JG934A)

I/O ports and slots 24RJ-45autosensing10/100/1000ports(IEEE802.3Type10BASE-T,IEEE802.3uType100BASE-TX,IEEE802.3abType1000BASE-T);Duplex:10BASE-T/100BASE-TX:halforfull;1000BASE-T:fullonly4SFP+fixed1000/10000SFP+ports

16SFP100/1000Mbpsports8SFPdual-personalityports;100/1000BASE-Xor100/1000BASE-TRJ-45ComboPorts4SFP+fixed1000/10000SFP+ports

48RJ-45autosensing10/100/1000ports(IEEE802.3Type10BASE-T,IEEE802.3uType100BASE-TX,IEEE802.3abType1000BASE-T);Duplex:10BASE-T/100BASE-TX:halforfull;1000BASE-T:fullonly4SFP+fixed1000/10000SFP+ports

Additional ports and slots 1RJ-45serialconsoleport 1RJ-45serialconsoleport 1RJ-45serialconsoleport

Power supplies 2powersupplyslots1minimumpowersupplyrequired(orderedseparately)

Physical characteristicsDimensions

Weight

17.32(w)x6.3(d)x1.72(h)in.(44x16x4.36cm)(1Uheight)11.02lb(5kg)

17.32(w)x14.17(d)x1.72(h)in.(44x36x4.36cm)(1Uheight)17.64lb(8kg)

17.32(w)x10.24(d)x1.72(h)in.(44x26x4.36cm)(1Uheight)11.02lb(5kg)

Memory and processor 1GBSDRAM,512MBflash;packetbuffersize:1.5MB

1GBSDRAM,512MBflash;packetbuffersize:1.5MB

1GBSDRAM,512MBflash;packetbuffersize:3MB

Mounting and enclosure MountsinanEIAstandard19-inchtelco rackorequipmentcabinet(hardwareincluded)

MountsinanEIAstandard19-inchtelco rackorequipmentcabinet(hardwareincluded)

MountsinanEIAstandard19-inchtelco rackorequipmentcabinet(hardwareincluded)

Performance1000MbLatency10GbpsLatencyThroughputRouting/SwitchingcapacityRoutingtablesizeMACaddresstablesize

<5µs<1.5µs96Mpps128Gbps512entries(IPv4),256entries(IPv6)16384entries

<5µs<1.5µs96Mpps128Gbps512entries(IPv4),256entries(IPv6)16384entries

<5µs<1.5µs130.9Mpps176Gbps512entries(IPv4),256entries(IPv6)16384entries

ReliabilityMTBF(years) 98.1 52.79 61.4

EnvironmentOperatingtemperatureOperatingrelativehumidityNon-operating/StoragetemperatureNon-operating/StoragerelativehumidityAcoustic

23°Fto113°F(-5°Cto45°C)10%to90%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensingHigh-speedfan:39.7dB;ISO7779

23°Fto113°F(-5°Cto45°C)10%to90%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensingLow-speedfan:47.1dB,High-speedfan: 50.7dB;ISO7779

23°Fto113°F(-5°Cto45°C)10%to90%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensingLow-speedfan:43.1dB,High-speedfan: 53.4dB;ISO7779

8

Datasheet|HP5130EISwitchSeries

HP 5130-24G-4SFP+ EI Switch (JG932A) HP 5130-24G-SFP-4SFP+ EI Switch (JG933A)

HP 5130-48G-4SFP+ EI Switch (JG934A)

Electrical characteristicsFrequencyMaximumheatdissipation

ACvoltageDCvoltageCurrentMaximumpowerratingIdlepower

50/60Hz64/88BTU/hr(67.52/92.84kJ/hr)

100–240VAC

2A26W19W

NotesIdlepoweristheactualpowerconsumptionofthedevicewithnoportsconnected.Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

50/60Hz102/204BTU/hr(107.61/215.22kJ/hr),forACpoweredunits.ForDCpoweredunitsheatdissipationis130BTU/hrminimum,232BTU/hrmaximum.100–240VAC-48to-60VDC5A60W30W

Idlepoweristheactualpowerconsumptionofthedevicewithnoportsconnected.Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.PowerratingsforACpowersupplyindicatedabove.ForDCinputpower,idlepoweris38Wandmaximumis68W.DCmaximuminputcurrentis8A.Unitsaresuppliedwithoutapowersupply.Customermustbuy1or2JD362A(AC)orJD366A(DC)powersupply.

50/60Hz130/153BTU/hr(137.15/161.42kJ/hr),for ACpoweredunits.ForDCpoweredunitsheatdissipationis130BTU/hrminimum,171BTU/hrmaximum.100–240VAC-48to-60VDC10A45W38W

Idlepoweristheactualpowerconsumptionofthedevicewithnoportsconnected.Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.PowerratingsforACpowerindicatedabove.Currentusedis5AmaximumwhenDCpowerused.ForDCinputpower,idlepoweris38W,maximumDCpowerusedis50W.

Safety UL60950-1;EN60825-1SafetyofLaserProducts-Part1;EN60825-2Safetyof LaserProducts-Part2;IEC60950-1;CAN/CSA-C22.2No.60950-1;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;RoHSCompliance

UL60950-1;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60950-1;CAN/CSA-C22.2No.60950-1;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;RoHSCompliance

UL60950-1;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60950-1;CAN/CSA-C22.2No.60950-1;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;ROHSCompliance

Emissions EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA;EN61000-4-11:2004;ANSIC63.4-2009;EN61000-3-3:2008;VCCIV-4/2012.04;EN6100-3-2:2006+A1:2009+A2:2009;EN61000-3-2:2006+A1:2009+A2:2009;EN61000-4-3:2006;EN61000-4-4:2012;EN61000-4-5:2006;EN61000-4-6:2009;AS/NZSCISPR22:2009ClassA;CISPR22:2008ClassA;EN55022:2010ClassA;EN61000-4-29:2000;CISPR24:2010;EN300386V1.6.1;VCCIV-3/2013.04ClassA

EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA;EN61000-4-11:2004;ANSIC63.4-2009;EN61000-3-3:2008;VCCIV-4/2012.04;EN6100-3-2:2006+A1:2009+A2:2009;EN61000-3-2:2006+A1:2009+A2:2009;EN61000-4-3:2006;EN61000-4-4:2012;EN61000-4-5:2006;EN61000-4-6:2009;AS/NZSCISPR22:2009ClassA;CISPR22:2008ClassA;EN55022:2010ClassA;EN61000-4-29:2000;CISPR24:2010;EN300386V1.6.1;VCCIV-3/2013.04ClassA

EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA;EN61000-4-11:2004;ANSIC63.4-2009;EN61000-3-3:2008;VCCIV-4/2012.04;EN6100-3-2:2006+A1:2009+A2:2009;EN61000-3-2:2006+A1:2009+A2:2009;EN61000-4-3:2006;EN61000-4-4:2012;EN61000-4-5:2006;EN61000-4-6:2009;AS/NZSCISPR22:2009ClassA;CISPR22:2008ClassA;EN55022:2010ClassA;EN61000-4-29:2000;CISPR24:2010;EN300386V1.6.1;VCCIV-3/2013.04ClassA

Immunity GenericESD

EN55024EN300386

EN55024EN300386

EN55024EN300386

Management IMC—IntelligentManagementCenter;command-lineinterface;Webbrowser;SNMPManager

IMC—IntelligentManagementCenter;command-lineinterface;Webbrowser;SNMPManager

IMC—IntelligentManagementCenter;command-lineinterface;Webbrowser;SNMPManager

Services RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

9

Datasheet|HP5130EISwitchSeries

HP 5130-24G-PoE+-4SFP+ (370W) EI Switch (JG936A)

HP 5130-48G-PoE+-4SFP+ (370W) EI Switch (JG937A)

HP 5130-24G-2SFP+-2XGT EI Switch (JG938A)

I/O ports and slots 24RJ-45autosensing10/100/1000ports(IEEE802.3Type10BASE-T,IEEE802.3uType100BASE-TX,IEEE802.3abType1000BASE-T);Duplex:10BASE-T/100BASE-TX:halforfull;1000BASE-T:fullonly4SFP+fixed1000/10000SFP+ports

48RJ-45autosensing10/100/1000ports(IEEE802.3Type10BASE-T,IEEE802.3uType100BASE-TX,IEEE802.3abType1000BASE-T);Duplex:10BASE-T/100BASE-TX:halforfull;1000BASE-T:fullonly4SFP+fixed1000/10000SFP+ports

24RJ-45autosensing10/100/1000ports(IEEE802.3Type10BASE-T,IEEE802.3uType100BASE-TX,IEEE802.3abType1000BASE-T);Duplex:10BASE-T/100BASE-TX:halforfull;1000BASE-T:fullonly2SFP+fixed1000/10000SFP+ports2RJ-451/10GBASE-Tports

Additional ports and slots 1RJ-45serialconsoleport 1RJ-45serialconsoleport 1RJ-45SerialConsolePort

Physical characteristicsDimensions

Weight

17.32(w)x11.81(d)x1.72(h)in.(44x30x4.37cm)(1Uheight)17.64lb(8kg)

17.32(w)x14.17(d)x1.72(h)in.(44x36x4.36cm)(1Uheight)17.64lb(8kg)

17.32(w)x6.3(d)x1.72(h)in.(44x16x 4.37cm)(1Uheight)6.61lb(3kg)

Memory and processor 1GBSDRAM,512MBflash;packetbuffersize:1.5MB

1GBSDRAM,512MBflash;packetbuffersize:3MB

1GBSDRAM;Packetbuffersize:1.5MB,512MBflash

Mounting and enclosure MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded)

MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded)

MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded)

Performance1000MbLatency10GbpsLatencyThroughputRouting/SwitchingcapacityRoutingtablesizeMACaddresstablesize

<5µs<1.5µs96Mpps128Gbps512entries(IPv4),256entries(IPv6)16384entries

<5µs<1.5µs130.9Mpps176Gbps512entries(IPv4),256entries(IPv6)16384entries

<5µs<1.5µsupto96Mpps128Gbps512entries(IPv4),256entries(IPv6)16384entries

ReliabilityMTBF(years) 48.3 37.1 87.2

EnvironmentOperatingtemperatureOperatingrelativehumidityNon-operating/StoragetemperatureNon-operating/StoragerelativehumidityAcoustic

23°Fto113°F(-5°Cto45°C)10%to90%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensingLow-speedfan:49.8dB,High-speedfan:52.9dB;ISO 7779

23°Fto113°F(-5°Cto45°C)10%to90%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensingLow-speedfan:50.6dB,High-speedfan:54.6dB;ISO7779

23°Fto113°F(-5°Cto45°C)10%to90%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensingLow-speedfan:19dB,High-speedfan:44.5dB;ISO7779

HP 5130 EI Switch SeriesSpecifications (continued)

10

Datasheet|HP5130EISwitchSeries

HP 5130-24G-PoE+-4SFP+ (370W) EI Switch (JG936A)

HP 5130-48G-PoE+-4SFP+ (370W) EI Switch (JG937A)

HP 5130-24G-2SFP+-2XGT EI Switch (JG938A)

Electrical characteristicsFrequencyMaximumheatdissipation

ACvoltageCurrentMaximumpowerratingIdlepowerPoEpower

50/60Hz102/1569BTU/hr(107.61/1655.29kJ/hr),forACpower.ForDCpowerminimumheatdissipationis85BTU/hrandmaximumheatdissipationis2559BTU/hr.100–240VAC10A460W30W370WPoE+

NotesMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.PoEpoweristhepowersuppliedbytheinternalpowersupply.WhensupplementedwiththeuseofanHP RPS1600RedundantPowerSystem,upto740WofPoE+canbesupplied.MaximumcurrentratingforDCpoweris25A.ACinputpoweris30Wtypical,and460Wmaximum(including370WPoE+consumption).DCinputvoltagerangeis-54to-57VDC.TotalDCinputpoweris25Wtypicaland790 Wwith740WPoE+powerconsumption.DCinputvoltagerangeis-54VDCto-57VDC.DCinputsourceistheHPRPS1600.

50/60Hz160/1671BTU/hr(168.8/1762.91kJ/hr),forACpower.ForDCpowerminimumheatdissipationis147BTU/hrand3037BTU/hrmaximum.100–240VAC10A490W47W370WPoE+

Idlepoweristheactualpowerconsumptionofthedevicewithnoportsconnected.Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.PoEpoweristhepowersuppliedbytheinternalpowersupply.WhensupplementedwiththeuseofanHP RPS1600RedundantPowerSystem,upto740WofPoE+canbesupplied.MaximumcurrentratingforDCpoweris25A.ACinputpoweris47Wtypical,and490Wmaximum(including370WPoE+consumption).DCinputvoltagerangeis-54 to-57VDC.TotalDCinputpoweris43Wtypicaland890Wwith800WPoE+powerconsumption.DCinputvoltagerangeis-54VDCto-57VDC.DCinputsourceistheHP RPS1600.

50/60Hz68/116BTU/hr(71.74/122.38kJ/hr)

100–240VAC,rated2A34W20W

Idlepoweristheactualpowerconsumptionofthedevicewithnoportsconnected.Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(if equipped),100%traffic,allportspluggedin,andallmodulespopulated.

Safety UL60950-1;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60950-1;CAN/CSA-C22.2No.60950-1;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;RoHSCompliance

UL60950-1;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60950-1;CAN/CSA-C22.2No.60950-1;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;RoHSCompliance

UL60950-1;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60950-1;CAN/CSA-C22.2No.60950-1;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;ROHSCompliance

Emissions EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA;EN61000-4-11:2004;ANSIC63.4-2009;EN61000-3-3:2008;VCCIV-4/2012.04;EN6100-3-2:2006+A1:2009+A2:2009;EN 61000-3-2:2006+A1:2009+A2:2009;EN61000-4-3:2006;EN61000-4-4:2012;EN61000-4-5:2006;EN61000-4-6:2009;AS/NZSCISPR22:2009ClassA;CISPR22:2008ClassA;EN55022:2010ClassA;EN61000-4-29:2000;CISPR24:2010;EN300386V1.6.1;VCCIV-3/2013.04ClassA

EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA;EN61000-4-11:2004;ANSIC63.4-2009;EN61000-3-3:2008;VCCIV-4/2012.04;EN6100-3-2:2006+A1:2009+A2:2009;EN 61000-3-2:2006+A1:2009+A2:2009;EN61000-4-3:2006;EN61000-4-4:2012;EN61000-4-5:2006;EN61000-4-6:2009;AS/NZSCISPR22:2009ClassA;CISPR22:2008ClassA;EN55022:2010ClassA;EN61000-4-29:2000;CISPR24:2010;EN300386V1.6.1;VCCIV-3/2013.04ClassA

EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA;EN61000-4-11:2004;ANSIC63.4-2009;EN61000-3-3:2008;VCCIV-4/2012.04;EN 6100-3-2:2006+A1:2009+A2:2009;EN61000-3-2:2006+A1:2009+A2:2009;EN61000-4-3:2006;EN61000-4-4:2012;EN61000-4-5:2006;EN61000-4-6:2009;AS/NZSCISPR22:2009ClassA;CISPR22:2008ClassA;EN55022:2010ClassA;EN61000-4-29:2000;CISPR24:2010;EN300386V1.6.1;VCCIV-3/2013.04ClassA

11

Datasheet|HP5130EISwitchSeries

HP 5130-24G-PoE+-4SFP+ (370W) EI Switch (JG936A)

HP 5130-48G-PoE+-4SFP+ (370W) EI Switch (JG937A)

HP 5130-24G-2SFP+-2XGT EI Switch (JG938A)

Immunity GenericESD

EN55024EN300386

EN55024EN300386

EN55024EN300386

Management IMC—IntelligentManagementCenter;command-lineinterface;Webbrowser;SNMPManager

IMC—IntelligentManagementCenter;command-lineinterface;Webbrowser;SNMPManager

IMC—IntelligentManagementCenter;Command-lineinterface;Webbrowser;SNMPManager

Services RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

12

HP 5130 EI Switch SeriesSpecifications (continued)

HP 5130-48G-2SFP+-2XGT EI Switch (JG939A)

HP 5130-24G-PoE+-2SFP+-2XGT (370W) EI Switch (JG940A)

HP 5130-48G-PoE+-2SFP+-2XGT (370W) EI Switch (JG941A)

I/O ports and slots 24RJ-45autosensing10/100/1000ports(IEEE802.3Type10BASE-T,IEEE802.3uType100BASE-TX,IEEE802.3abType1000BASE-T);Duplex:10BASE-T/100BASE-TX:halforfull;1000BASE-T:fullonly2SFP+fixed1000/10000SFP+ports2RJ-451/10GBASE-Tports

24RJ-45autosensing10/100/1000ports(IEEE802.3Type10BASE-T,IEEE802.3uType100BASE-TX,IEEE802.3abType1000BASE-T);Duplex:10BASE-T/100BASE-TX:halforfull;1000BASE-T:fullonly2SFP+fixed1000/10000SFP+ports2RJ-451/10GBASE-Tports

48RJ-45autosensing10/100/1000ports(IEEE802.3Type10BASE-T,IEEE802.3uType100BASE-TX,IEEE802.3abType1000BASE-T);Duplex:10BASE-T/100BASE-TX:halforfull;1000BASE-T:fullonly2SFP+fixed1000/10000SFP+ports2RJ-451/10GBASE-Tports

Additional ports and slots 1RJ-45serialconsoleport 1RJ-45serialconsoleport 1RJ-45serialconsoleport

Physical characteristicsDimensions

Weight

17.32(w)x6.3(d)x1.72(h)in.(44x16x4.37cm)(1Uheight)11.02lb(5kg)

17.32(w)x16.54(d)x1.72(h)in.(44x42x4.37cm)(1Uheight)13.23lb(6kg)

17.32(w)x16.54(d)x1.72(h)in.(44x42x4.37cm)(1Uheight)15.43lb(7kg)

Mounting and enclosure MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded)

MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded)

MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded)

Performance1000MbLatency10GbpsLatencyThroughputRouting/SwitchingcapacityRoutingtablesizeMACaddresstablesize

<5µs<1.5µsupto130.9Mpps176Gbps512entries(IPv4),256entries(IPv6)16384entries

<5µs<1.5µsupto96Mpps128Gbps512entries(IPv4),256entries(IPv6)16384entries

<5µs<1.5µsupto130.9Mpps176Gbps512entries(IPv4),256entries(IPv6)16384entries

ReliabilityMTBF(years) 51.0 44.4 26.8

EnvironmentOperatingtemperatureOperatingrelativehumidityNonoperating/StoragetemperatureNonoperating/StoragerelativehumidityAcoustic

23°Fto113°F(-5°Cto45°C)10%to90%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensingLow-speedfan:43.1dB,High-speedfan:53.4dB;ISO7779

23°Fto113°F(-5°Cto45°C)10%to90%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensingLow-speedfan:37.3dB,High-speedfan:47.1dB;ISO7779

23°Fto113°F(-5°Cto45°C)10%to90%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensingLow-speedfan:47.3dB,High-speedfan:50dB;ISO7779

Datasheet|HP5130EISwitchSeries

13

Datasheet|HP5130EISwitchSeries

HP 5130-48G-2SFP+-2XGT EI Switch (JG939A)

HP 5130-24G-PoE+-2SFP+-2XGT (370W) EI Switch (JG940A)

HP 5130-48G-PoE+-2SFP+-2XGT (370W) EI Switch (JG941A)

Electrical characteristicsFrequencyMaximumheatdissipation

Voltage

CurrentMaximumpowerratingIdlePowerPoEPower

50/60Hz122/184BTU/hr(128.71/194.12kJ/hr)

100–240VAC,rated(dependingonpowersupplychosen)2A54W36W

NotesPowerratingsforACpowerindicatedabove.Currentusedis5AMaxwhenDC Powerused.ForDCinputpower,idle poweris36W,maximumDCpowerusedis54W.

50/60Hz151/1450BTU/hr(159.3/1529.75kJ/hr),forACpower.ForDCPower68BTU/hrandmaxheatdissipationis2627.3BTU/hr100–240VAC,rated(dependingonpowersupplychosen)10A460W31W370WPoE+

PoEPoweristhepowersuppliedbytheinternalpowersupply.WhensupplementedwiththeuseofanHP RPS1600RedundantPowerSystem,upto740WofPoE+canbesupplied.MaxcurrentratingforDCpoweris25A.ACInputpoweris31Wtypical,and460Wmax(including370WPoE+consumption.DCInputvoltagerangeis-54to-57VDC.TotalDCinputpoweris25WTypicaland790Wwith740WPoE+Powerconsumption.DCInputSourceistheHP RPS1600.

50/60Hz147/1603BTU/hr(155.08/1691.17kJ/hr),forACpower.ForDCpowerminheatdissipationis102BTU/hrandmaxheatdissipationis3105BTU/hr100–240VAC,rated(dependingonpowersupplychosen)10A70W43W370WPoE+

PoEPoweristhepowersuppliedbytheinternalpowersupply.WhensupplementedwiththeuseofanHP RPS1600RedundantPowerSystem,upto740WofPoE+canbesupplied.MaxcurrentratingforDCpoweris25A.ACInputpoweris43Wtypical,and470Wmax(including370WPoE+consumption.DCInputvoltagerangeis-54to-57VDC.TotalDCinputpoweris30Wtypicaland910Wwith800WPoE+Powerconsumption.DCInputSourceistheHP RPS1600.

Safety UL60950-1;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60950-1;CAN/CSA-C22.2No.60950-1;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;ROHSCompliance

UL60950-1;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60950-1;CAN/CSA-C22.2No.60950-1;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;ROHSCompliance

UL60950-1;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60950-1;CAN/CSA-C22.2No.60950-1;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;ROHSCompliance

Emissions EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA;EN61000-4-11:2004;ANSIC63.4-2009;EN61000-3-3:2008;VCCIV-4/2012.04;EN6100-3-2:2006+A1:2009+A2:2009;EN61000-3-2:2006+A1:2009+A2:2009;EN61000-4-3:2006;EN61000-4-4:2012;EN61000-4-5:2006;EN61000-4-6:2009;AS/NZSCISPR22:2009ClassA;CISPR22:2008ClassA;EN55022:2010ClassA;EN61000-4-29:2000;CISPR24:2010;EN300386V1.6.1;VCCIV-3/2013.04ClassA

EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA;EN61000-4-11:2004;ANSIC63.4-2009;EN61000-3-3:2008;VCCIV-4/2012.04;EN6100-3-2:2006+A1:2009+A2:2009;EN61000-3-2:2006+A1:2009+A2:2009;EN61000-4-3:2006;EN61000-4-4:2012;EN61000-4-5:2006;EN61000-4-6:2009;AS/NZSCISPR22:2009ClassA;CISPR22:2008ClassA;EN55022:2010ClassA;EN61000-4-29:2000;CISPR24:2010;EN300386V1.6.1;VCCIV-3/2013.04ClassA

EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA;EN61000-4-11:2004;ANSIC63.4-2009;EN61000-3-3:2008;VCCIV-4/2012.04;EN6100-3-2:2006+A1:2009+A2:2009;EN61000-3-2:2006+A1:2009+A2:2009;EN61000-4-3:2006;EN61000-4-4:2012;EN61000-4-5:2006;EN61000-4-6:2009;AS/NZSCISPR22:2009ClassA;CISPR22:2008ClassA;EN55022:2010ClassA;EN61000-4-29:2000;CISPR24:2010;EN300386V1.6.1;VCCIV-3/2013.04ClassA

Immunity GenericESD

EN55024EN300386

EN55024EN300386

EN55024EN300386

Management IMC—IntelligentManagementCenter;Command-lineinterface;Webbrowser;SNMPManager

IMC—IntelligentManagementCenter;Command-lineinterface;Webbrowser;SNMPManager

IMC—IntelligentManagementCenter;Command-lineinterface;Webbrowser;SNMPManager

Services RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

14

Datasheet|HP5130EISwitchSeries

Standards and Protocols(appliestoallproductsinseries)

Device management RFC1157SNMPv1/v2cRFC1305NTPv3RFC2573(SNMPv3Applications)

RFC2819(RMONgroupsAlarm,Event,History,andStatisticsonly)RFC3416(SNMPProtocolOperationsv2)HTMLandTelnetmanagement

MultipleConfigurationFilesSNMPv3andRMONRFCsupportSSHv1/SSHv2SecureShellTACACS/TACACS+WebUI

General protocols IEEE802.1adQ-in-QIEEE802.1DMACBridgesIEEE802.1pPriorityIEEE802.1QVLANsIEEE802.1sMultipleSpanningTreesIEEE802.1wRapidReconfigurationofSpanningTreeIEEE802.1XPAEIEEE802.3Type10BASE-TIEEE802.3ab1000BASE-TIEEE802.3adLinkAggregationControlProtocol(LACP)IEEE802.3ae10-GigabitEthernetIEEE802.3afPoweroverEthernetIEEE802.3atPoweroverEthernetPlusIEEE802.3i10BASE-TIEEE802.3u100BASE-XIEEE802.3xFlowControlIEEE802.3z1000BASE-XRFC768UDPRFC783TFTPProtocol(revision2)

RFC791IPRFC792ICMPRFC793TCPRFC826ARPRFC854TELNETRFC951BOOTPRFC1213ManagementInformationBase forNetworkManagementofTCP/IP-basedInternetRFC1305NTPv3RFC1350TFTPProtocol(revision2)RFC1519CIDRRFC1812IPv4RoutingRFC1866HypertextMarkupLanguage—2.0RFC2131DHCPRFC2236IGMPSnoopingRFC2616HTTPCompatibilityv1.1RFC2665DefinitionsofManagedObjectsfortheEthernet-likeInterfaceTypes

RFC2668DefinitionsofManagedObjectsforIEEE802.3MediumAttachmentUnits(MAUs)RFC2865RemoteAuthenticationDialInUserService(RADIUS)RFC2866RADIUSAccountingRFC3414User-basedSecurityModel(USM)forversion3oftheSimpleNetworkManagementProtocol(SNMPv3)RFC3415View-basedAccessControlModel(VACM)fortheSimpleNetworkManagementProtocol(SNMP)RFC3418ManagementInformationBase(MIB)fortheSimpleNetworkManagementProtocol(SNMP)RFC3576ExttoRADIUS(CoAonly)RFC4213BasicIPv6TransitionMechanisms802.1r—GARPProprietaryAttributeRegistrationProtocol(GPRP)

IPv6 RFC1981IPv6PathMTUDiscoveryRFC2460IPv6SpecificationRFC2461IPv6NeighborDiscoveryRFC2463ICMPv6RFC2464TransmissionofIPv6overEthernetNetworksRFC3162RADIUSandIPv6

RFC3306Unicast-Prefix-basedIPv6MulticastAddressesRFC3315DHCPv6(clientandrelay)RFC3484DefaultAddressSelectionfor IPv6RFC3736StatelessDynamicHostConfigurationProtocol(DHCP)ServiceforIPv6

RFC4291IPversion6AddressingArchitectureRFC4293MIBforIPRFC4443ICMPv6RFC4861IPv6NeighborDiscoveryRFC4862IPv6StatelessAddressAuto-configuration

MIBs RFC1212ConciseMIBDefinitionsRFC1213MIB-IIRFC1493BridgeMIBRFC1757RemoteNetworkMonitoringMIBRFC2096IPForwardingTableMIBRFC2233InterfaceMIBRFC2571SNMPFrameworkMIBRFC2572SNMP-MPDMIB

RFC2573SNMP-NotificationMIBRFC2573SNMP-TargetMIBRFC2574SNMPUSMMIBRFC2618RADIUSAuthenticationClientMIBRFC2620RADIUSAccountingClientMIBRFC2665Ethernet-like-MIBRFC2668802.3MAUMIBRFC2674802.1pandIEEE802.1QBridge MIB

RFC2737EntityMIB(version2)RFC2819RMONMIBRFC2863TheInterfacesGroupMIBRFC2925PingMIBRFC3414SNMP-user-based-SMMIBRFC3415SNMP-view-based-ACMMIBRFC3418MIBforSNMPv3RFC3621PowerEthernetMIB

Network management IEEE802.1ABLinkLayerDiscoveryProtocol(LLDP)

RFC2819fourgroupsofRMON:1 (statistics),2(history),3(alarm),and9 (events)

ANSI/TIA-1057LLDPMediaEndpointDiscovery(LLDP-MED)SNMPv1/v2c/v3

Security IEEE802.1XPort-basedNetworkAccess ControlRFC1492TACACS+RFC2138RADIUSAuthentication

RFC2139RADIUSAccountingRFC2865RADIUS(clientonly)RFC2866RADIUSAccounting

SecureSocketsLayer(SSL)SSHv2SecureShell

15

Datasheet|HP5130EISwitchSeries

HP 5130 EI Switch Series accessories (continued)

Transceivers HPX110100MSFPLCLH40Transceiver(JD090A)HPX110100MSFPLCLH80Transceiver(JD091A)HPX110100MSFPLCFXTransceiver(JD102B)HPX110100MSFPLCLXTransceiver(JD120B)HPX115100MSFPLCBX10-UTransceiver(JD100A)HPX115100MSFPLCBX10-DTransceiver(JD101A)HPX1251GSFPLCLH401310nmTransceiver(JD061A)HPX1201GSFPLCLH401550nmTransceiver(JD062A)HPX1251GSFPLCLH70Transceiver(JD063B)HPX1201GSFPLCLH100Transceiver(JD103A)HPX1201GSFPLCSXTransceiver(JD118B)HPX1201GSFPLCLXTransceiver(JD119B)HPX1201GSFPLCBX10-UTransceiver(JD098B)HPX1201GSFPLCBX10-DTransceiver(JD099B)HPX1201GSFPRJ-45TTransceiver(JD089B)HPX13010GSFP+LCSRTransceiver(JD092B)HPX13010GSFP+LCLRTransceiver(JD094B)HPX24010GSFP+toSFP+0.65mDirectAttachCopperCable(JD095C)HPX24010GSFP+toSFP+1.2mDirectAttachCopperCable(JD096C)HPX24010GSFP+toSFP+3mDirectAttachCopperCable(JD097C)HPX24010GSFP+toSFP+5mDirectAttachCopperCable(JG081C)

Cables HP0.5mMultimodeOM3LC/LCOpticalCable(AJ833A)HP1mMultimodeOM3LC/LCOpticalCable(AJ834A)HP2mMultimodeOM3LC/LCOpticalCable(AJ835A)HP5mMultimodeOM3LC/LCOpticalCable(AJ836A)HP15mMultimodeOM3LC/LCOpticalCable(AJ837A)HP30mMultimodeOM3LC/LCOpticalCable(AJ838A)HP50mMultimodeOM3LC/LCOpticalCable(AJ839A)HPPremierFlexLC/LCMulti-modeOM42fiber1mCable(QK732A)HPPremierFlexLC/LCMulti-modeOM42fiber2mCable(QK733A)HPPremierFlexLC/LCMulti-modeOM42fiber5mCable(QK734A)HPPremierFlexLC/LCMulti-modeOM42fiber15mCable(QK735A)HPPremierFlexLC/LCMulti-modeOM42fiber30mCable(QK736A)HPPremierFlexLC/LCMulti-modeOM42fiber50mCable(QK737A)

HP 5130-24G-SFP-4SFP+ EI Switch (JG933A) HP5500150WACPowerSupply(JD362A)HP5500150WDCPowerSupply(JD366A)

HP 5130-48G-4SFP+ EI Switch (JG934A) HPRPS800RedundantPowerSupply(JD183A)HPRPS1600RedundantPowerSystem(JG136A)HPRPS16001600WACPowerSupply(JG137A)HPX290500V1mRPSCable(JD186A)HPX2901000AJD5Non-PoE2mRPSCable(JD188A)

HP 5130-24G-PoE+-4SFP+ (370W) EI Switch (JG936A) HPRPS1600RedundantPowerSystem(JG136A)HPRPS16001600WACPowerSupply(JG137A)HPX2901000AJD52mRPSCable(JD187A)

RatethisdocumentSharewithcolleaguesSign up for updates hp.com/go/getupdated

©Copyright2014–2015Hewlett-PackardDevelopmentCompany,L.P.Theinformationcontainedhereinissubjecttochangewithoutnotice.TheonlywarrantiesforHPproductsandservicesaresetforthintheexpresswarrantystatementsaccompanyingsuchproductsandservices.Nothinghereinshouldbeconstruedasconstitutinganadditionalwarranty.HPshallnotbeliablefortechnicaloreditorialerrorsoromissionscontainedherein.

sFlowisaregisteredtrademarkofInMonCorp.

4AA5-4495ENW,August2015,Rev.5

Datasheet|HP5130EISwitchSeries

HP 5130-48G-PoE+-4SFP+ (370W) EI Switch (JG937A) HPRPS1600RedundantPowerSystem(JG136A)HPRPS16001600WACPowerSupply(JG137A)HPX2901000AJD52mRPSCable(JD187A)

HP 5130-48G-2SFP+-2XGT EI Switch (JG939A) HPRPS800RedundantPowerSupply(JD183A)HPRPS1600RedundantPowerSystem(JG136A)HPRPS16001600WACPowerSupply(JG137A)HPX290500V1mRPSCable(JD186A)HPX2901000AJD5Non-PoE2mRPSCable(JD188A)HP5130-24G-PoE+-2SFP+-2XGT(370W)EISwitch(JG940A)HPX2901000AJD52mRPSCable(JD187A)HP5130-48G-PoE+-2SFP+-2XGT(370W)EISwitch(JG941A)HPX2901000AJD52mRPSCable(JD187A)

Learn more at hp.com/networking

HP 5130 EI Switch Series accessories