![Page 2: H igh E fficiency L ighting P rojects Let us HELP you!](https://reader036.fdocuments.us/reader036/viewer/2022062800/56814101550346895dacc940/html5/thumbnails/2.jpg)
From a 455 Watt metal halide fixture to a ‘daylight’ T8, 6
lamp, 8’ fixture at 224 Watts
Same grid - replaced 1 for 1
• Was burning 86,450 Watts• Is burning 42,560 Watts• Savings: +50% • Payback: 11 months
with +30% more light!
Direct Mail & Merchandise Co.
![Page 3: H igh E fficiency L ighting P rojects Let us HELP you!](https://reader036.fdocuments.us/reader036/viewer/2022062800/56814101550346895dacc940/html5/thumbnails/3.jpg)
Notice the increase in lumens on the floor of the
completed side
With a brighter, whiter, crisper light
![Page 4: H igh E fficiency L ighting P rojects Let us HELP you!](https://reader036.fdocuments.us/reader036/viewer/2022062800/56814101550346895dacc940/html5/thumbnails/4.jpg)
Replaced a total of 287 (455 Watts) fixtures with a total of 384 (156 Watts) 16’ fixtures:
• Was burning 130,585 Watts• Is burning 27,423 Watts• Savings with sensors: 79% • With more light!• Payback: 5.5 months
Warehouse
Ceilings = 28’ to the bar joists
![Page 5: H igh E fficiency L ighting P rojects Let us HELP you!](https://reader036.fdocuments.us/reader036/viewer/2022062800/56814101550346895dacc940/html5/thumbnails/5.jpg)
Ma
inte
na
nc
e Costs• We install 24,000 hour lamps, your HID’s are 20,000 hour
• Our lamps cost $2.00/piece, your HID lamps cost $50.00/piece
• Our ballasts cost $15.00/piece, HID ballasts cost $65.00/ea.
![Page 6: H igh E fficiency L ighting P rojects Let us HELP you!](https://reader036.fdocuments.us/reader036/viewer/2022062800/56814101550346895dacc940/html5/thumbnails/6.jpg)
Retail Merchandise Mail Order Company
From: 400 Watt Metal Halide
To: 6 lamp, T8, 8’ fixtures, 224 Watts
Energy Savings: 50%
Payback: 10 months
![Page 7: H igh E fficiency L ighting P rojects Let us HELP you!](https://reader036.fdocuments.us/reader036/viewer/2022062800/56814101550346895dacc940/html5/thumbnails/7.jpg)
Metal halide fixtures create poor light distribution. See the difference on the
bags
Using the same grid, 1:1 replacement
![Page 8: H igh E fficiency L ighting P rojects Let us HELP you!](https://reader036.fdocuments.us/reader036/viewer/2022062800/56814101550346895dacc940/html5/thumbnails/8.jpg)
Notice the real color of the wall using 5000K lamps
Previous T12 lamps distorts color rendition
Wood working shop specializing in showcase cabinetry
![Page 9: H igh E fficiency L ighting P rojects Let us HELP you!](https://reader036.fdocuments.us/reader036/viewer/2022062800/56814101550346895dacc940/html5/thumbnails/9.jpg)
Finishing Stain Room
Last stop before product delivery to the customer
From 2 lamp, 238 Watt, 8’, T12 fixtures retrofit to 4 lamp, 112 Watt,
T8 fixtures.
Energy savings: 50%
Payback: 13 months “I can see the real colors now!”
![Page 10: H igh E fficiency L ighting P rojects Let us HELP you!](https://reader036.fdocuments.us/reader036/viewer/2022062800/56814101550346895dacc940/html5/thumbnails/10.jpg)
From this to this!
![Page 11: H igh E fficiency L ighting P rojects Let us HELP you!](https://reader036.fdocuments.us/reader036/viewer/2022062800/56814101550346895dacc940/html5/thumbnails/11.jpg)
Metal Distributor
Our fixture match the lumen output of a HID fixture with a
NEW lamp!
![Page 12: H igh E fficiency L ighting P rojects Let us HELP you!](https://reader036.fdocuments.us/reader036/viewer/2022062800/56814101550346895dacc940/html5/thumbnails/12.jpg)
Metal Distributor:
At 36 feet:Qty 66 – 455 Watt HPS
Qty 72 – 145 Watt, 4’, T12, 2 lamp, high output
At 36 feet:Qty 66 – 224 Watt High Intensity Fluorescent fixtures
Qty 72 – 78 Watt, 4’, 2 lamp, high lumen, T8 with a Mira4 high bay reflector
![Page 13: H igh E fficiency L ighting P rojects Let us HELP you!](https://reader036.fdocuments.us/reader036/viewer/2022062800/56814101550346895dacc940/html5/thumbnails/13.jpg)
Was burning 40,470 Watts Is burning 20,400 Watts
![Page 14: H igh E fficiency L ighting P rojects Let us HELP you!](https://reader036.fdocuments.us/reader036/viewer/2022062800/56814101550346895dacc940/html5/thumbnails/14.jpg)
Machine & Metal Stamping
See this sign?
From: T12, two 8’ slimline lamps, total of 138 Watts
To: T8, two 4’ lamps, high lumen, total of 78 Watts
![Page 15: H igh E fficiency L ighting P rojects Let us HELP you!](https://reader036.fdocuments.us/reader036/viewer/2022062800/56814101550346895dacc940/html5/thumbnails/15.jpg)
Tool & Die
It is hard to believe this is the same metal stamping shop
From: 2 lamp, T12, 8’, slimline lamps
To: two 4’, T8 lamps, 8’ fixtures with aluminum polished reflectors and electronic ballasts
Energy Savings: 50%
Payback: 12 months
![Page 16: H igh E fficiency L ighting P rojects Let us HELP you!](https://reader036.fdocuments.us/reader036/viewer/2022062800/56814101550346895dacc940/html5/thumbnails/16.jpg)
Corrugated Box Manufacturing Building (just before moving in)
455 watt (with ballast) metal halide fixtures
Each fixture has one lamp to fire the fixture
224 Watt (with ballast) high intensity fluorescent fixtures
Each fixture has six, T8, 4’, daylight lamps
If one lamp prematurely burns out the other 5 stay on
![Page 17: H igh E fficiency L ighting P rojects Let us HELP you!](https://reader036.fdocuments.us/reader036/viewer/2022062800/56814101550346895dacc940/html5/thumbnails/17.jpg)
Our lighting projects flood the area with our broadband specular reflector versus your circular point source lighting that is typical on HID fixtures
Think of circular MH or HPS light fixtures like a flashlight. There are dark spots between the fixtures and lots of shadows
![Page 18: H igh E fficiency L ighting P rojects Let us HELP you!](https://reader036.fdocuments.us/reader036/viewer/2022062800/56814101550346895dacc940/html5/thumbnails/18.jpg)
Manufacturer of metal laser cutting machines
Was: 455 Watt (with ballast)metal halide
Is: 224 Watt, (with ballast) 6 lamp, T8 high lumen fixtures
Simple payback: <12 months
![Page 19: H igh E fficiency L ighting P rojects Let us HELP you!](https://reader036.fdocuments.us/reader036/viewer/2022062800/56814101550346895dacc940/html5/thumbnails/19.jpg)
T12 fluorescents in this room
(you can tell by the green tint)
Metal halides in this room
T8, daylight lamps provide the same color around the entire
facility
![Page 20: H igh E fficiency L ighting P rojects Let us HELP you!](https://reader036.fdocuments.us/reader036/viewer/2022062800/56814101550346895dacc940/html5/thumbnails/20.jpg)
Three 455 watt metal halide fixtures spaced 16’ apart
Replaced with three 224 Watt, 8’, 6 lamp, high
lumen, T8 fixtures mounted end to end
Customer Training & Show Room
![Page 21: H igh E fficiency L ighting P rojects Let us HELP you!](https://reader036.fdocuments.us/reader036/viewer/2022062800/56814101550346895dacc940/html5/thumbnails/21.jpg)
Beer Distributor
From 400 Watt metal halide to 8’, 6 lamp, T8 at half the watts per fixture
![Page 22: H igh E fficiency L ighting P rojects Let us HELP you!](https://reader036.fdocuments.us/reader036/viewer/2022062800/56814101550346895dacc940/html5/thumbnails/22.jpg)
Re-tread Tire Manufacturer
![Page 23: H igh E fficiency L ighting P rojects Let us HELP you!](https://reader036.fdocuments.us/reader036/viewer/2022062800/56814101550346895dacc940/html5/thumbnails/23.jpg)
Replaced 320 Watt Pulse Start Metal Halide with 224 Watt, 6 lamp, T8, 8’ fixture
with daylight lamps
![Page 24: H igh E fficiency L ighting P rojects Let us HELP you!](https://reader036.fdocuments.us/reader036/viewer/2022062800/56814101550346895dacc940/html5/thumbnails/24.jpg)
The color rendering index of the existing metal halide lamps
is 65 at best
ESG installs daylight lamps with a CRI of 85
Look at the difference on the walls
![Page 25: H igh E fficiency L ighting P rojects Let us HELP you!](https://reader036.fdocuments.us/reader036/viewer/2022062800/56814101550346895dacc940/html5/thumbnails/25.jpg)
Water Bottling Plant
24 x 7 x 365 Operation
![Page 26: H igh E fficiency L ighting P rojects Let us HELP you!](https://reader036.fdocuments.us/reader036/viewer/2022062800/56814101550346895dacc940/html5/thumbnails/26.jpg)
The grid pattern remained the same. Each fixture was replaced 1:1 with a
high efficiency fluorescent fixture
Replaced all 455 Watt, metal halide fixtures 224 Watt high
intensity fluorescent T8 fixtures
![Page 27: H igh E fficiency L ighting P rojects Let us HELP you!](https://reader036.fdocuments.us/reader036/viewer/2022062800/56814101550346895dacc940/html5/thumbnails/27.jpg)
Food Distribution Warehouse
Aisle 47
From 465 Watt High Pressure Sodium to 224 Watt, 6 lamp, T8
fixtures with daylight lamps
1:1 replacement