General Model RAKD Specifications Small Metal Rotameter · 2011-04-25 · Model RAKD Small Metal...

20
Model RAKD Small Metal Rotameter General Specifications A float is guided concentrically in a conic metal tube. The position of this float is magnetically transmitted to the indicator. The short-tube Rotameter is used for measurement of low flow rates of liquids and gases. Its special application is in troubled, opaque or aggressive mediums and under high pressure. The instrument is mounted in a vertical pipeline with flow direction upwards. When the process conditions are changed the scale needs to be replaced by a new one of which the values should be calculated. Fig. 1a Indicator RAKD with tube without valve Fig. 1b Tube RAKD with valve FeatureS - Different process connections like internal threads and flanges - With fine control valve (horizontal connection) and without valve (vertical connection) - All wetted parts of stainless steel AISI 316Ti (1.4571) - Measuring accuracy acc. Directive VDI/VDE 3513 sheet 2 (q G =50%) - Round industrial standardized stainless steel housing with degree of protection IP 66/67 - Light, guided floats resulting in low pressure loss and stable float movement - Maximum flow range 1-250 l/h water resp. 40-8000 l/h air, portioned in 13 flow ranges with a relation of 1:10 - Pressure controller (normal up to 25 bar at 20°C) for a maximum flow of 100 l/h water resp. 3.250 l/h air (only in combination with valve) - Electronic µP-controlled transmitter with linearized output - Electrical connection by fast connection technique (Quickon) - Limit switches, also available as “Fail Safe” version - Connection of common transformer isolated barriers and transmitter power supplies possible - Intrinsically safe version (Ex-i) (ATEX, CSA, SAA, NEPSI) - Suitable for SIL application, FMEDA report available Contents Features page 1 Standard Specification page 2 Controller (/R1, /R3) page 4 SIL- Compliance page 4 Hazardous Area Specifications page 4 Installation page 6 Temperature Specification page 8 Model and option specifications page 8 Dimensions page 14 Connection Types page 17 Installation Lengths depending on Connection Types and Size page 17 Weights page 17 Planning Hints page 17 GS 01R01B30-00E-E ©Copyright June 2004 (Rü) 8th edition, February 2009 (Rü7 Rota Yokogawa GmbH & Co. KG Rheinstr. 8 D-79664 Wehr Germany GS 01R01B30-00E-E

Transcript of General Model RAKD Specifications Small Metal Rotameter · 2011-04-25 · Model RAKD Small Metal...

Page 1: General Model RAKD Specifications Small Metal Rotameter · 2011-04-25 · Model RAKD Small Metal Rotameter General Specifications A float is guided concentrically in a conic metal

Model RAKDSmall Metal Rotameter

GeneralSpecifications

A float is guided concentrically in a conic metal tube. The position of this float is magnetically transmitted to the indicator.The short-tube Rotameter is used for measurement of low flow rates of liquids and gases.Its special application is in troubled, opaque or aggressive mediums and under high pressure.The instrument is mounted in a vertical pipeline with flow direction upwards.When the process conditions are changed the scale needs to be replaced by a new one of which the values should be calculated.

Fig. 1a Indicator RAKD with tube without valve

Fig. 1b Tube RAKD with valve

FeatureS- Different process connections like internal threads and flanges- With fine control valve (horizontal connection) and without valve (vertical connection)- All wetted parts of stainless steel AISI 316Ti (1.4571)- Measuring accuracy acc. Directive VDI/VDE 3513 sheet 2 (qG=50%)- Round industrial standardized stainless steel housing with degree of protection IP 66/67 - Light, guided floats resulting in low pressure loss and stable float movement- Maximum flow range 1-250 l/h water resp. 40-8000 l/h air, portioned in 13 flow ranges with a relation of 1:10- Pressure controller (normal up to 25 bar at 20°C) for a maximum flow of 100 l/h water resp. 3.250 l/h air (only in combination with valve)- Electronic µP-controlled transmitter with linearized output- Electrical connection by fast connection technique (Quickon) - Limit switches, also available as “Fail Safe” version - Connection of common transformer isolated barriers and transmitter power supplies possible- Intrinsically safe version (Ex-i) (ATEX, CSA, SAA, NEPSI)- Suitable for SIL application, FMEDA report available

ContentsFeatures page 1Standard Specification page 2Controller (/R1, /R3) page 4SIL- Compliance page 4Hazardous Area Specifications page 4Installation page 6Temperature Specification page 8Model and option specifications page 8Dimensions page 14Connection Types page 17Installation Lengths depending on Connection Types and Size

page 17

Weights page 17Planning Hints page 17

GS 01R01B30-00E-E©Copyright June 2004 (Rü)

8th edition, February 2009 (Rü7

Rota Yokogawa GmbH & Co. KGRheinstr. 8D-79664 WehrGermany

GS 01R01B30-00E-E

Page 2: General Model RAKD Specifications Small Metal Rotameter · 2011-04-25 · Model RAKD Small Metal Rotameter General Specifications A float is guided concentrically in a conic metal

2

GS 01R01B30-00E-E 8th edition, Feb. 19, 2009-00 All Rights Reserved. Copyright © 2004, Rota Yokogawa

StaNDarD SPeCIFICatIONSthe responsibility with respect to the suitability andaccording application of our flowmeter is only situated by the customer.

MeaSurING tubeMaterials of wetted parts : Stainless steel AISI 316Ti (1.4571) other materials on requestFluids to be measured : Liquid or gasMeasuring range : see flow tableMeasuring range ratio : 10:1Process connections :– Inner thread : G1/4; 1/4 NPT; G 3/8; 3/8; NPT– Cutting ring : 6 mm; 8 mm; 10 mm; 12 mm– Cutting ring (Swagelok) : 6 mm; 8 mm; 10 mm; 12 mm– Nozzle : 6 mm; 8 mm– Flange : acc. EN 1092-1 DN15 and DN25 PN40; acc. ASME B 16.5 ½” and 1” 150 lbs, 300 lbsProcess pressure : depends on process connection; see model codeProcess temperature : without valve -25°C to 250°C with valve -25°C to 150°C See also fig. 6. Lower temperatures on request.Measurement accuracy : acc. Directive VDI/VDE 3513 sheet 2 (qG=50%) 4% Installation :– Installation position : vertical– Flow direction : upwards– Face to face length : 125 mm (with flange 250 mm)Weight : see table 12

LOCaL INDICatOr(Indicator/Code -T)Principle :The indication is made by magnetic coupling of a magnet enclosed in the float and a magnet in the indication unit, which follows the movements of the float.Indication scale : Flow unitsIndicator housing– Material : Stainless steel AISI 304 (1.4301)– Degree of Protection : IP66/67Scales : - Standard : removable aluminium plate with scale (double scale as option)transportation and storage condition : - 40°C to +110°C.

eLeCtrONIC traNSMItter (Indicator/Code -E)temperature range : -25°C to +65°Ctransportation and storage condition : -40°C to +70°CProcess-/ ambient temperature : The dependency of the process temperature from the ambient temperature is shown in fig.6. Power supply : 13.5 ... 30 V DCLoad resistance : (U-13.5V) /20mAanalog output : 4-20 mALinearity : ≤ ± 0.25% f.s.Hysteresis : ≤ ± 0.15% f.s.Repeatability : ≤ ± 0.16% f.s.Influence of power supply : ≤ ± 0.1% f.s.Temp. coefficient of analog output : ≤ ± 0.5% /10 K f.s.AC-part of analog output : ≤ ± 0.15% f.s. Long time stability : ≤ ± 0.2% / yearMaximum output current : 21.5 mAOutput current in case of failure : ≤ 3.6 mA (NAMUR NE 43)Response time (99%) : approx. 1 sPulse output (Option /CP) : Electronic switch with galvanic isolation acc. EN 60947-5-6 (NAMUR)- Pulse length : 200 ms- Max. frequency : 4 Hz- Pulse rate : Qmax ≤ 1 → 0.0001 : 1 < Qmax ≤ 10 → 0.001 etc. e.g.. Qmax = 1 m3/h → 1 Puls = 0.0001 m3 = 0.1 electromagnetic compatibility (eMC) - Acc. EN 61326-1: 2006, Class A, Table 2 and EN 61326-2-3 : 2006

POWer SuPPLY FOr eLeCtrONIC traNSMItter (Option /U__) type : power supply with galvanically separated input and output SINEAX B811Supply voltage : 24 V to 60 V AC/DC 85 V to 230 V AC Maximum load : 750 ΩOutput signal : 0/4 mA - 20 mA

eLeCtrICaL CONNeCtION (Indicator/Code -E) :type : QuickonCable diameter : 4 – 6 mmMaximum cross section of core : Ø 0.34 to 0.75 mm2

Page 3: General Model RAKD Specifications Small Metal Rotameter · 2011-04-25 · Model RAKD Small Metal Rotameter General Specifications A float is guided concentrically in a conic metal

3

GS 01R01B30-00E-E 8th edition, Feb. 19, 2009-00All Rights Reserved. Copyright © 2004, Rota Yokogawa

LIMIt SWItCHeS IN StaNDarD verSION (option /K1 to /K3)type : Inductive proximity switch SC2-NO acc. DIN EN 60947-5-6 Nominal voltage : 8V DCOutput signal : ≤ 1 mA or ≥ 3 mAHysteresis : < 0.5mm

LIMIt SWItCHeS IN FaIL SaFe verSION (option /K6 to /K10)type : Inductive proximity switch SJ2-SN; SJ2-S1N acc. DIN EN 60947-5-6 Nominal voltage : 8V DCOutput signal : ≤ 1 mA or ≥ 3 mAHysteresis : < 0.5mm

HYStereSIS OF LIMIt SWItCHeSMin-contact / Max-contact :- pointer movement : ≈ 0.8 mm- float movement : ≈ 0.8 mmMinimum distance between 2 contacts : ≈ 8 mm

eLeCtrICaL CONNeCtION (option /K1 to /K10) :type : QuickonCable diameter : 4 – 6 mmMaximum cross section of core : Ø 0.34 to 0.75 mm2

POWer SuPPLY FOr LIMIt SWItCHeS (Option /W__) type : Transmitter relay acc. DIN EN 50227 (NAMUR) - KFA6-SR2-Ex1-W (230 V AC) - KFA5-SR2-Ex1-W (115 V AC) - KFD2-SR2-Ex1-W (24 V DC) - KHA6-SH-Ex1 (230 V AC), Fail Safe, only one channel - KFD2-SH-Ex1 (24 V DC), Fail Safe, only one channelPower supply : - 230 V AC ± 10%, 45-65Hz - 115 V AC ± 10%, 45-65Hz - 24 V DC ± 25%relay output : 1 or 2 potential-free change over contact(s) Switching capacity : max. 250V AC, max. 2 ANote :If Fail-Safe limit switch option /K6 or /K7 is ordered, for power supply option /W2E or /W4E must be selected.If Fail-Safe limit switch option /K8, /K9 or /K10 is ordered, for power supply option /W2F or /W4F must be selected.

SWItCHING LeveLS FOr LIMIt SWItCHeS table 1 Min, Max and Min-Max-contact in standard version

Option /K1 Option /K2 Option /K3

Function PointerSignal Signal Signal

SC2-N0 SC2-N0 SC2-N0

MAXabove LV below LV

---- ----

1 mA 3 mA

1 mA 3 mA

Function PointerSignal Signal Signal

SC2-N0 SC2-N0 SC2-N0

MINabove LV below LV

3 mA 1 mA

---- ----

3 mA 1 mA

Note: LV = Limit value

table 2 Min, Max and Min-Max-contact in fail-safe version

Option /K6 Option /K7 Option /K8

Function PointerSignal Signal Signal

SJ2-SN SJ2-SN SJ2-SN

MAXabove LV below LVFail Safe

---- --------

1 mA 3 mA1 mA

1 mA 3 mA1 mA

Function PointerSignal Signal Signal

SJ2-SN SJ2-SN SJ2-SN

MINabove LV below LVFail Safe

3 mA 1 mA1 mA

---- --------

3 mA 1 mA1 mA

Note: LV = Limit value

table 3 Limit switch as Min-Min-contact in fail-safe version

Option /K9

Function PointerSignal

SJ2-S1N

MINabove LV below LVFail Safe

3 mA 1 mA1 mA

Function PointerSignal

SJ2-SN

MINabove LV below LVFail Safe

3 mA 1 mA1 mA

Note: LV = Limit value

table 4 Limit switch as Max-Max-contact in fail-safe version

Option /K10

Function PointerSignal

SJ2-SN

MAXabove LV below LVFail Safe

1 mA 3 mA1 mA

Function PointerSignal

SJ2-S1N

MAXabove LV below LVFail Safe

1 mA 3 mA1 mA

Note: LV = Limit value

Page 4: General Model RAKD Specifications Small Metal Rotameter · 2011-04-25 · Model RAKD Small Metal Rotameter General Specifications A float is guided concentrically in a conic metal

4

GS 01R01B30-00E-E 8th edition, Feb. 19, 2009-00 All Rights Reserved. Copyright © 2004, Rota Yokogawa

HazarDOuS area SPeCIFICatIONSraKD with ateX- certification “intrinsic safe” (option /KS1) Certificate : KEMA 00ATEX 1037XOutput signal : 4–20 mAexplosion proof : Ex ia IIC T6; group II ; category 2Gentity parameter : Table 6

analog output

Pulse output

Limit switch type 2/K1-/K3

Limit switch type 3/K1-/K3

Limit switch type 2/K6-/K8

Limit switch type 3/K6-/K8

Ui [V] 30 16 16 16 16 16

Ii[ mA] 100 20 25 52 25 52

Pi [mW] 750 64 64 169 64 169

Li [mH] 0.73 0 0.15 0.15 0.1 0.1

Ci [nF] 2.4 0 150 150 30 30

temperature specification :Table 7

Configura-tion

Max. ambient

temperature

Max. process tem-

perature

temperature class

Transmitter4-20mA / Pulse

65°C 65°CT6

50°C 80°C

45°C 100°C T5

38°C 135°C T4

Limit switch(es) type 2

65°C 65°C T6

80°C 80°CT5

59°C 100°C

100°C 100°CT4

73°C 135°C

Limit switch(es)type 3

24°C 65°C T6

37°C 80°CT5

34°C 100°C

57°C 80°C

T454°C 100°C

48°C 135°CFor the configuration where a transmitter is combined with limit switches, the temperature class is determined by the most restrictive combinations of maximum ambient temperature and maximum process temperature.Description of limit switch type 2 and 3 see ATEX certificates from Pepperl & Fuchs:- PTB 99 ATEX 2219X ( SC2-NO) for /K1 to /K3- PTB 00 ATEX 2049X (SJ2-S.N) for /K6 to /K10

raKD “non incendive” (option /KN1)Type “n” (non incendive) acc. EN 60079-15.explosion proof : Ex nL IIC T6 protection „nL”; group II ; category 3GDust proof : Ex II 3D; group II ; category 3D Max. surface temperature : 80°C entity parameter : see table 6temperature specification : see table 7

CONtrOLLer (Option /r1 and r3)Differential pressure controller for a constant flow at fluctuations of the process pressure.These are no valves to reduce the pressure.- Controller /r1 for liquids with variable inlet or outlet pressure and for gases with variable inlet pressure and constant back pressure.- Controller /r3 for gases with fluctuations of the back pressure.Max. liquid flow : 100 l/hMax. gas flow : 3250 l/hMax. pressure : 25 barrecommended differential pressure : >400 mbartemperature range : -25°C to + 80°CMaterials :Table 5

Housing Diaphragm Springs

/R1 / /R3 CrNi-Steel PTFE CrNi-Steel

F2.EPS

l/h air at 20°C ; 1.013 bar abs.

Inlet pressure

Fig. 2 Diagram controller characteristic

SIL- COMPLIaNCe

raKD with local indicator and standard or fail safe limit switches (raKD[][]-[][]SS-[][][][][]-t[][]NNN/K1…K10):Suitable for application in safety functions up to and including SIL2.

raKD with valve and controller with local indicator and standard or fail safe limit switches(raKD[][]-[][]SS-[][]v[][]-t[][]NNN/r[]/K1…K10):Suitable for application in safety functions up to and including SIL1.

Reliability data available on request in FMEDA report.

Page 5: General Model RAKD Specifications Small Metal Rotameter · 2011-04-25 · Model RAKD Small Metal Rotameter General Specifications A float is guided concentrically in a conic metal

5

GS 01R01B30-00E-E 8th edition, Feb. 19, 2009-00All Rights Reserved. Copyright © 2004, Rota Yokogawa

raKD with NePSI- certification “intrinsic safe” (China) (option /NS1) :Certificate : GYJ05153Output signal : 4–20 mA explosion proof : Ex ia IIC T6Max. tamb. : 65°C Limit switches : option /K1 to /K8, see certificates GYJ06542X and GYJ06543Xentity parameter : Table 8

temperature specification :Table 9

Max. ambienttemperature

Max. process temperature

temperature class

65°C 65°C T650°C 80°C T645°C 95°C T5

Description of limit switch type 2 and 3 see ATEX certificates from Pepperl & Fuchs:- PTB 99 ATEX 2219X ( SC2-NO) for /K1 to /K3- PTB 00 ATEX 2049X (SJ2-S.N) for /K6 to /K10

raKD with CCOe- certification (India) Option /KS1 must be selected. CCOE- certificate is available at your Yokogawa Sales Office.

Intrinsically safe and dust proof limit switches with ateX-certification (only for indicator t with option /K1 ... /K10) (option /KS2) :Certificate : - PTB 99 ATEX 2219X ( SC2-NO) - PTB 00 ATEX 2049X (SJ 2-S.N) - ZELM 03 ATEX 0128X (for dust proof) explosion proof : EEx ia IIC T6, group II category 2GDust proof: Ex iaD 20 T 108 °C, group I I category 1D Max. surface temperature : T108°C entity parameter : see certificate of conformity

Intrinsically safe limit switches with Saa-certification (australia) (only for indicator t with option /K1 ... /K10) (option /SS1) :Certificate : AUS Ex 02.3838Xexplosion proof : Ex ia IIC T1 ... T6entity parameter : see certificate of conformity

analog output

Pulse output

Limit switch type 2/K1-/K3

Limit switch type 3/K1-/K3

Limit switch type 2/K6-/K8

Limit switch type 3/K6-/K8

Ui [V] 30 16 20 20 16 16

Ii[ mA] 100 20 25 52 25 52

Pi [mW] 750 64 64 169 64 169

Li [mH] 0.73 0 0.15 0.15 0.1 0.1

Ci [nF] 2.4 0 150 150 30 30

Intrinsically safe limit switches with CSa-certification (uSa + Canada) (only for indicator t with option /K1 ... /K10) (option /CS1) :Certificate : 1007121 (LR 96321-2)explosion proof : Cl. I, Div. 1, Grp A, B, C, D Cl. II, Div. 1, Grp. E, F, G Cl. III, Div. 1 or Class I, Zone 0, Gp. IIC T6 (Ta = 60°C)entity parameter : see FM-control drawing 116-0165b

Power Supply for the intrinsically safe electronic transmitter (option /u__)type : Intrinsically safe power supply with galvanically separated input and output. SINEAX B811Certificate : PTB 97 ATEX 2083Supply voltage : 24 V to 60 V AC/DC 85 V to 230 V AC Maximum load impedance: 750 ΩOutput signal : 0/4 mA - 20 mAControl circuit : [EEx ia] IIC; group II; category (1)Gentity parameters : see fig. 5 and certificate

Power supply for intrinsically safe limit switches (option W__) type : acc. DIN EN 50227 (NAMUR) - KFA5-SR2-Ex*-W (115 V AC) - KFA6-SR2-Ex*-W (230 V AC) - KFD2-SR2-Ex*-W (24 V DC) - KHA6-SH-Ex1 (230 V AC), Fail Safe, 1 channel - KFD2-SH-Ex1 (24 V DC), Fail Safe, 1 channelCertificates - KFA5-SR2-Ex*-W: ATEX: PTB 00 ATEX 2081 CSA: 1029981 (LR 36087-19) SAA: AUS Ex 3631X - KFA6-SR2-Ex*-W: ATEX: PTB 00 ATEX 2081 CSA: 1029981 (LR 36087-19) SAA: AUS Ex 3631X - KHA6-SH-Ex1: ATEX: PTB 00 ATEX 2043 - KFD2-SR2-Ex*-W: ATEX: PTB 00 ATEX 2080 CSA: 1029981 (LR 36087-19) SAA: AUS Ex 2244X NEPSI: GYJ071116 - KFD2-SH-Ex1: ATEX: PTB 00 ATEX 2042 NEPSI: GYJ04443 Control circuit (ateX): [EEx ia] IIC; group II; category (1)GDentity parameter: see fig. 5 (ATEX) and certificatePower supply : - 230 V AC ± 10%, 45-65Hz - 115 V AC ± 10%, 45-65Hz - 24 V DC ± 25%relay output : 1 or 2 potential-free changeover contact(s) Switching capacity : max. 250V AC, max. 2 A

Page 6: General Model RAKD Specifications Small Metal Rotameter · 2011-04-25 · Model RAKD Small Metal Rotameter General Specifications A float is guided concentrically in a conic metal

6

GS 01R01B30-00E-E 8th edition, Feb. 19, 2009-00 All Rights Reserved. Copyright © 2004, Rota Yokogawa

-

+

+

-

-

+-

+

~ ~

T; S = Connector QUICKON

EN 60947-5-6 (NAMUR) Limit switch SC2-N0

RAKD - T80 /KS1

Transmitter relayKFA6-SR2-Ex2.W

ooooo

PTB 00ATEX 2081

L = 97mHC = 2320nF

I = 19.1mAP = 51mW

U = 10.6VEEx ia IIC

KFA6-SR2-Ex2.W

Power supply 230V AC

Limit switch MIN

Limit switch MAX

BU2

BN

BU

BN

1

2

1

10

12

6

4

3

1

11

7

8

9

14 15

MIN

F

MAX

S

T

U

Hazardous Area Safe Area

F3.EPS

i i i i i

KEMA 00ATEX 1037X

L = 0.15mHC = 150nF

I = 25mAP = 64mW

U = 16VEx ia IIC T6...T5

Limit switch type 2

Fig. 3 ATEX- version of RAKD with 2 limit switches in combination with transmitter relay

INStaLLatION

Power supplyU = 13.5 to 30V DC

T = Connector QUICKON

F

RAKD-E80

G

T

Output 4-20mA

U - 13.5V20mA

R <L

2

-

+

1

+ -

-

+

F4.EPS

Fig. 4 RAKD with electronic transmitter

Page 7: General Model RAKD Specifications Small Metal Rotameter · 2011-04-25 · Model RAKD Small Metal Rotameter General Specifications A float is guided concentrically in a conic metal

7

GS 01R01B30-00E-E 8th edition, Feb. 19, 2009-00All Rights Reserved. Copyright © 2004, Rota Yokogawa

Limit switch / Puls

T; S = Connector QUICKON

Ex ia IIC T6...T5U = 16V

P = 64mWI = 20mA

C = 0nFL = 0mH

KEMA 00ATEX 1037X

Puls outputEx ia IIC T6...T5 U = 10.6V

KEMA 00ATEX 1037X

L = 0.15mHC = 150nF

U = 16VI = 25mAP = 64mW

PTB 00ATEX 2081

L = 97mHC = 2320nF

I = 19.1mAP = 51mW

Limit switch type 2

EN 60947-5-6 (NAMUR)

Limit switch orPulse output

KFA6-SR2-Ex1.W

KFA6-SR2-Ex1.WTransmitter relay

EEx ia IIC

4-20mA output

I = 100mAU = 30V

KEMA 00ATEX 1037X

L = 0.73mHC = 2.4nFP = 0.75W

Ex ia IIC T6...T5

RAKD-E80 Option /KS1 SINEAX B 811

Option: /U2FTransmitter power supply

PTB 97ATEX 2083

Tamax = 55°C

C = 178nFL = 6.7mH

SINEAX B 811

U = 21V

P = 0.66W

EEx ia IIC

I = 75mA

Output4-20mA

Power supply230V AC

iii

ii

o

iii

ii

oo

oo

-P+P

-

-+

~ ~

ii

iii o

+

L-

L+

-

+

-

+

oo

oo

BU

1 K

15 K2

1

2

31

14

78

9

15

BN 1

1

2

+/~

1 IN

-/~5

6 IN

10

OUT4

OUT 9

S

S U

F

G

T T

Hazardous Area Safe Area

Fig. 5 ATEX- version of RAKD with electronic transmitter with power supply and limit switch or pulse output in combination with transmitter relay

Page 8: General Model RAKD Specifications Small Metal Rotameter · 2011-04-25 · Model RAKD Small Metal Rotameter General Specifications A float is guided concentrically in a conic metal

8

GS 01R01B30-00E-E 8th edition, Feb. 19, 2009-00 All Rights Reserved. Copyright © 2004, Rota Yokogawa

teMPerature SPeCIFICatION

50 55 60 65 7075

100

200

Illustration of maximum allowable operation temperature depending onambient temperature for Rotameter type RAKD

Max

. ope

ratio

n te

mpe

ratu

re [°

C]

Ambient temperature [°C]

75 80

125

150

175

225

250

275

Version without valve Version with valve F6.EPS

MODeL aND OPtION SPeCIFICatIONSPlease make your decision in this order:1. Option controller with controller without controller with controller without controller

2. Version with valve without valve with valve without valve3. Max. Flow

Cone

1.0 - 100 l/h water40 - 3250 l/h air31 - 51

1.0 - 250 l/h water40 - 8000 l/h air31 - 53

1.0 - 100 l/h water40 - 3250 l/h air31 - 51

1.0 - 250 l/h water5000 - 8000 l/h air52 - 53

4. Process connection Inner threadCutting ringCutting ring (Swagelok)Nozzle

Inner threadCutting ringCutting ring (Swagelok)Nozzle

Inner threadCutting ringCutting ring (Swagelok)NozzleFlange

Inner threadCutting ringCutting ring (Swagelok)Flange

Specify the model code according the mentioned page

Page 9 Page 10 Page 11 Page 12

Ordering instructionsStandard:a: Model, suffix and option codeb: Flow conditionsc: Temperatured: Pressuree: Viscosityf: DensityFor gases: cross reference of the scaleOption/Bx: customer specification notes

Fig. 6

For option /KS1 or /KN1 (Ex-i-versions ATEX) the maximum values for ambient and process temperature according to the respec-tive temperature class mentioned in fig. 5 and table 7 must be regarded.For option /NS1 (Ex-i-version NEPSI) the maximum values for ambient and process temperature according to the respective tem-perature class mentioned in table 9 must be regarded.The minimum ambient temperature is -25°C. Lower temperatures on request.

Page 9: General Model RAKD Specifications Small Metal Rotameter · 2011-04-25 · Model RAKD Small Metal Rotameter General Specifications A float is guided concentrically in a conic metal

9

GS 01R01B30-00E-E 8th edition, Feb. 19, 2009-00All Rights Reserved. Copyright © 2004, Rota Yokogawa

RA

KD

with

va

lve

an

d c

on

tro

ller

(op

tion

/R

1 a

nd

/R

3)

1. 0

- 1

00

l/h

wa

ter

/ 4

0 -

32

50

l/h

air:

Pro

cess

co

nn

ect

ion

Inte

rna

l th

rea

d:

R

p 1

/4 P

N 2

5

41

R

3

1/4

NP

T P

N 2

5

41

T

3

Cu

ttin

g r

ing:

?

6 P

N 2

5

53

C

3

? 8

PN

25

54

C3

? 1

0 P

N 2

5

55

C

3

? 1

2 P

N 2

5

56

C3

No

zzle

:

?

6 P

N 1

0

53

P1

?

8 P

N 1

0

54

P1

Material: 1.4571 / AISI 316Ti S

S

Ind

ica

tor

Typ

e:

L

oca

l in

dic

ato

r T

In

dic

ato

r w

ith

ele

ctric

ou

tpu

t

E

Ho

usi

ng

typ

e:

Sta

inle

ss s

tee

l 8

0

Po

we

r su

pp

ly:

no

ne

,

for

loca

l in

dic

ato

r „T

“ N

NN

for

ele

ctric

typ

e „

E“,

2

4V

DC

, 2-w

ire

,

4-2

0m

A

42

4

Ve

rsio

n

W

ith v

alv

e in

inle

t

Gask

et

Va

lve

se

at

P

TF

E

Silv

er

VS

E

PT

FE

P

CT

FE

V

PE

W

ith v

alv

e in

ou

tlet

Ga

sket

Va

lve

se

at

P

TF

E

Silb

er

VS

A

PT

FE

P

CT

FE

V

PA

Ma

x. F

low

C

on

e

Wa

ter

(l/h

) A

ir

(l/h

)

1

40

31

1.6

6

0

32

2.5

100

33

4.0

1

50

34

6.0

2

00

37

10

32

5

41

16

5

00

42

25

8

00

43

40

1

40

0

44

60

2

00

0

47

10

0

32

50

51

Co

ne

Dp

mb

ar

31-3

7

6

41-4

3

8

44-5

1

11

R

KD

A

S

S

8

0

/

For

calc

ula

tion to o

ther

fluid

s / pro

cess

conditi

ons

ple

ase

use

our

sizi

ng p

rogra

m D

ure

p_V

.

T6.EPS

optio

ns

Sw

ag

elo

k:

? 6

PN

25

53

W

3 ?

8 P

N 2

5

54

W3

? 1

0 P

N 2

5

55

W

3 ?

12

PN

25

56

W3

Page 10: General Model RAKD Specifications Small Metal Rotameter · 2011-04-25 · Model RAKD Small Metal Rotameter General Specifications A float is guided concentrically in a conic metal

10

GS 01R01B30-00E-E 8th edition, Feb. 19, 2009-00 All Rights Reserved. Copyright © 2004, Rota Yokogawa

RA

KD

with v

alv

e 1.0

– 2

50 l/h

wate

r / 40

– 8

000 l/h

air:

P

roce

ss

conn

ectio

n

Inte

rna

l th

rea

d:

G 1

/4 P

N 4

0

41

G4

G 1

/4 P

N 1

00

41

G6

1/4

NP

T P

N 4

0

41

T4

1/4

NP

T P

N 1

00

41

T6

Cu

ttin

g r

ing:

?

6 P

N 4

0

53

C

4

? 6

PN

10

0

53

C

6

? 8

PN

40

54

C4

? 8

PN

100

54

C6

? 1

0 P

N 4

0

55

C4

? 1

0 P

N 1

00

55

C

6

? 1

2 P

N 4

0

56

C4

? 1

2 P

N 1

00

56

C6

No

zzle

:

?

6 P

N 1

0

53

P

1?

8 P

N 1

0

54

S

S

In

dic

ato

r

Typ

e:

L

oca

l in

dic

ato

rT

In

dic

ato

r w

ith

e

lectr

ic o

utp

ut

E

Ho

usin

g typ

e:

S

tain

less s

tee

l8

0

Po

we

r su

pp

ly:

no

ne

,fo

r lo

ca

l in

dic

ato

r „T

“N

NN

for

ele

ctr

ic t

yp

e „

E“,

24

V D

C,

2w

ire

, -2

0m

A

42

4

Ve

r sio

n

With

va

lve in

inp

ut

Ga

ske

t V

alv

e s

eat

PT

FE

S

i lver

PT

FE

P

CT

FE

With v

alv

e in

ou

tpu

t

Ga

ske

t V

alv

e s

ea

t

PT

FE

S

i lver

P

TF

E

PC

TF

E

Ma

x.

Flo

w

Cone

W

ate

r (l/h

) A

i r

(l/h

)

1

40

31

1.6

6

0

32

2.5

1

00

33

4.0

1

50

34

6.0

2

00

37

10

3

25

41

16

5

00

42

25

80

0

43

40

14

00

44

60

2

00

0

47

10

0

32

50

51

16

0

50

00

52

25

0

80

00

53

Ko

nu

s

Dp

mb

ar

31- 3

7

6

41-4

3

8

44-5

1

11

52-5

3

13

R

KD

A

S

S

8

0

/

siz

ing

pro

gra

m D

ure

p_

V.

T7.EPS

op

tio

ns

Sw

ag

elo

k:

?

6 P

N 4

0

53

W

4 ?

6 P

N 1

00

53

W

6 ?

8 P

N 4

0

54

W4

? 8

PN

100

54

W6

? 1

0 P

N 4

0

55

W4

? 1

0 P

N 1

00

55

W

6 ?

12

PN

40

56

W4

? 1

2 P

N 1

00

56

W6

P1

Fo

r ca

lcu

latio

n t

o o

the

r flu

ids /

pro

ce

ss c

on

ditio

ns p

lea

se

use

ou

r

Material: 1.4571 / AISI 316Ti

Page 11: General Model RAKD Specifications Small Metal Rotameter · 2011-04-25 · Model RAKD Small Metal Rotameter General Specifications A float is guided concentrically in a conic metal

11

GS 01R01B30-00E-E 8th edition, Feb. 19, 2009-00All Rights Reserved. Copyright © 2004, Rota Yokogawa

RA

KD

with

ou

t va

lve

1

.0

– 1

00

l/h

wa

ter

/ 4

0

– 3

25

0 l/h

air:

Ma

x.

Flo

w

Co

ne

W

ate

r

(l/h

)

Air

(l/h

)

1

40

31

1.6

6

0

32

2.5

1

00

33

4.0

1

50

34

6.0

2

00

37

10

3

25

41

16

5

00

42

25

8

00

43

40

1

40

0

44

60

2

00

0

47

10

0

32

50

51

Co

ne

Dp m

ba

r 31-3

7

6

41-4

3

8

44-5

1

11

Pro

ce

ss

co

nn

ection

F

lan

ge

:

DN

15

PN

40

01

D4

DN

25

PN

40

02

D

4

AN

SI ½

15

0 lbs

01

A

1

AN

SI 1

150

lbs

02

A

1

AN

SI

½ 3

00

lb

s

01

A2

A

NS

I 1

30

0 lb

s

02

A

2

In

tern

al th

rea

d:

G

1/4

PN

100

41

G

6

G 1

/4 P

N 1

60

41

G7

1/4

NP

T P

N 1

00

41

T

6

1/4

NP

T P

N 1

60

41

T7

C

utt

ing

rin

g:

?

6 P

N 1

00

53

C

6

? 6

PN

160

53

C7

? 8

PN

100

54

C6

? 8

PN

160

54

C7

? 1

0 P

N 1

00

55

C

6

? 1

0 P

N 1

60

55

C7

? 1

2 P

N 1

00

56

C6

? 1

2 P

N 1

60

56

C

7

N

ozzle

:

? 6

PN

10

53

P1

? 8

PN

10

54

P1

S

S

Ve

rsio

n

W

ith

ou

t va

lve

NN

N

Ind

ica

tor

T

yp

e:

L

oca

l in

dic

ato

r T

In

dic

ato

r w

ith

e

lectr

ic o

utp

ut

E

H

ou

sin

g typ

e:

Sta

inle

ss s

tee

l 8

0

P

ow

er

su

pp

ly:

no

ne

,

for

loca

l in

dic

ato

r „T

“ N

NN

for

ele

ctr

ic t

yp

e „

E“,

24

V D

C,

2-w

ire

, 4-2

0m

A

42

4

R

KD

A

S

S

N

NN

80

/

Fo

r ca

lcu

latio

n to

oth

er

flu

ids /

pro

ce

ss c

on

ditio

ns p

lea

se

use

ou

rsiz

ing

pro

gra

m D

ure

p_

V.

T8.EPS

options

S

wa

ge

lok:

?

6 P

N 1

00

53

W

6 ?

6 P

N 1

60

53

W7

? 8

PN

100

54

W6

? 8

PN

160

54

W7

? 1

0 P

N 1

00

55

W

6 ?

10

PN

16

0

55

W7

? 1

2 P

N 1

00

56

W6

? 1

2 P

N 1

60

56

W

7

Material: 1.4571 / AISI 316Ti

Page 12: General Model RAKD Specifications Small Metal Rotameter · 2011-04-25 · Model RAKD Small Metal Rotameter General Specifications A float is guided concentrically in a conic metal

12

GS 01R01B30-00E-E 8th edition, Feb. 19, 2009-00 All Rights Reserved. Copyright © 2004, Rota Yokogawa

RA

KD

with

out v

alve

160

250

l/h w

ater

/ 50

00 –

800

0 l/h

air:

Max

. Flo

w

Con

e

Wat

e r

(l/h)

A

ir

(l/h )

160

5000

52

25

0 80

00

53

Con

e D

p m

bar

52-5

3 13

Pro

cess

co

nnec

tion

Fla

nge:

D

N 1

5 P

N 4

0 01

D

4 D

N 2

5 P

N 4

0 02

D

4 A

NS

I ½ 1

50 lb

s 01

A

1

AN

SI 1

150

lbs

02

A1

A

NS

I ½ 3

00 lb

s 01

A

2

AN

SI 1

300

lbs

02

A2

In

tern

al th

read

:

G 3

/8 P

N 1

00

42

G6

G 3

/8 P

N 1

60

42

G7

3/8

NP

T P

N 1

00

42

T6

3/8

NP

T P

N 1

60

42

T7

Cut

ting

ring:

?

12

PN

10 0

56

C

6 ?

12

PN

160

56

C

7

S

S

V

ersi

on

W

ithou

t val

ve

NN

N

Indi

cato

r

T

ype:

Loca

l ind

icat

or

T

Indi

cato

r w

ith

elec

tric

out

put

E

Hou

sing

type

:

S

tain

less

ste

el

80

Pow

er s

uppl

y:

none

, fo

r lo

cal i

ndic

ator

„T

“ N

NN

for

elec

tric

type

„E

“,

24V

DC

, 2- w

ire,

4-20

mA

424

R

KD

A

S

S

N

NN

80

/

For

cal

cula

tion

to o

ther

flui

ds /

proc

ess

cond

ition

s pl

ease

use

our

sizi

ng p

rogr

am D

urep

_V.

T9.EPS

optio

ns

Sw

agel

ok:

?

12

PN

10 0

56

W

6 ?

12

PN

160

56

W

7

Material: 1.4571 / AISI 316Ti

Page 13: General Model RAKD Specifications Small Metal Rotameter · 2011-04-25 · Model RAKD Small Metal Rotameter General Specifications A float is guided concentrically in a conic metal

13

GS 01R01B30-00E-E 8th edition, Feb. 19, 2009-00All Rights Reserved. Copyright © 2004, Rota Yokogawa

OPtIONSOptions Option

codeDescription restriction

Indicator /A12 US- engineering units Only for indicator E

Marking /B1/B4/B8/BG/BD

Tag plate (SS) fixed by wire and marking on scaleNeutral versionCustomer provided marking on labelCustomer specific notes on scaleDual Scale

Plate 12 x 40 mm; max. 45 digits Not with option /P6; not with Ex-proof type

Max. 45 digits Adjustment only possible for 1 fluid

Limit switches /K1/K2/K3/K6/K7/K8/K9/K10

MIN- contactMAX- contactMIN-MAX- contact, MIN-MIN- contact, MAX-MAX- contactMIN- contact “Fail safe” versionMAX- contact “Fail safe” versionMIN-MAX- contact “Fail safe” versionMIN-MIN- contact “Fail safe” versionMAX-MAX- contact “Fail safe” version

Only for indicator T

Only for indicator TOnly for indicator TOnly for indicator T

Pulse output /CP Pulse output, acc. EN 60947-5-6 (NAMUR) Only for indicator E; not with limit switches

Hazardous area approvals

/KS1/KS2/KN1/CS1/SS1/NS1

ATEX intrinsically safe „ia“ATEX gas and dust proof limit switches, category 2G 1DATEX category 3G „nL“ / 3DCSA intrinsic safe approval for limit switches (US+CAN) SAA approval for limit switches (Australia)NEPSI approval (China)

Not for indicator T without limit switchesOnly for indicator T with limit switchesNot for indicator T without limit switchOnly for indicator T with limit switchesOnly for indicator T with limit switchesNot for indicator T without limit switches

Test and certificates /H1/PP/P2/P3/P6/PM1/PM4/PM5

Oil + fat free for wetted surfaces acc.ASTM G93-03,level CPressure test report measuring systemCertificate of Compliance with the order acc. to EN 10204: 2004- 2.1As /P2 +Test report acc. to EN 10204: 2004- 2.2 Material certificate acc. to EN 10204: 2004- 3.1PAMI test (1 test point : metering tube)PAMI test (4 test points : metering tube, connection heads, sealing plug)PAMI test (5 test points : metering tube, connection pieces, slip on flanges)

Only for tube, connection heads, screw sealing plug

Only for models with valveOnly for models with process connection D4, A1, A2

Gost approval /QR1/QR2

Russian GOST approvalKazakh GOST approval

Controller /R1

/R3

Pre pressure controller 1.4571 (only with valve in inlet; for gas with variable pre pressure and liquids with variable pre and back pressure)Back pressure controller 1.4571 (only with valve in outlet; for gas with variable back pressure)

Only for process connection R3, T3, C3, W3, P1; only with valveOnly for process connection R3, T3, C3, W3, P1; only with valve

Power supply forelectronic transmitter

/U2F/U3F

SINEAX B811, 85 - 250 V AC, EEx iSINEAX B811, 24 V AC/DC, EEx i

Only for indicator E Only for indicator E

Power supply for limit switches (transmitter relay)

/W1A/W1B/W2A/W2B/W2E/W2F/W4A/W4B/W4E/W4F

KFA5-SR2-Ex1.W / 115 V AC, 1 channelKFA5-SR2-Ex2.W / 115 V AC, 2 channelKFA6-SR2-Ex1.W / 230 V AC, 1 channelKFA6-SR2-Ex2.W / 230 V AC, 2 channelKHA6-SH-Ex1 / 230 V AC, 1 channel, Fail Safe2x KHA6-SH-Ex1 / 230 V AC, 1 channel, Fail SafeKFD2-SR2-Ex1.W / 24 V DC, 1 channelKFD2-SR2-Ex2.W / 24 V DC, 2 channelKFD2-SH-Ex1 / 24 V DC, 1 channel, Fail Safe2x KFD2-SH-Ex1 / 24 V DC, 1 channel, Fail Safe

Only for limit switches /K1, /K2, /K3 Only for limit switches /K1, /K2, /K3Only for limit switches /K1, /K2, /K3Only for limit switches /K1, /K2, /K3Only for limit switches /K6, /K7Only for limit switches /K8, /K9, /K10Only for limit switches /K1, /K2, /K3Only for limit switches /K1, /K2, /K3Only for limit switches /K6, /K7Only for limit switches /K8, /K9, /K10

Instruction manuals /IEn/IDn/IFn

Quantity of instruction manuals in EnglishQuantity of instruction manuals in GermanQuantity of instruction manuals in French

n = 1 to 9 selectable n = 1 to 9 selectable n = 1 to 9 selectable If no instruction manual is selected, only a CD with instruction manuals is shipped with the flowmeter.

Page 14: General Model RAKD Specifications Small Metal Rotameter · 2011-04-25 · Model RAKD Small Metal Rotameter General Specifications A float is guided concentrically in a conic metal

14

GS 01R01B30-00E-E 8th edition, Feb. 19, 2009-00 All Rights Reserved. Copyright © 2004, Rota Yokogawa

DIMeNSIONSNote : The dimensions a ; b ; c ; L1 ; L2 ; L3 are listed in table 10 and 11.

F7.EPS

F8.EPS

Fig. 7 Version without valve Fig. 8 Version with flange connection

F13.EPS

Fig. 9 Back view with mounting

Page 15: General Model RAKD Specifications Small Metal Rotameter · 2011-04-25 · Model RAKD Small Metal Rotameter General Specifications A float is guided concentrically in a conic metal

15

GS 01R01B30-00E-E 8th edition, Feb. 19, 2009-00All Rights Reserved. Copyright © 2004, Rota Yokogawa

F9.EPS

Cutting ring

F12.EPS

Cutting ring

Fig. 10 Version with inlet valve

Fig. 11 Version with outlet valve

Page 16: General Model RAKD Specifications Small Metal Rotameter · 2011-04-25 · Model RAKD Small Metal Rotameter General Specifications A float is guided concentrically in a conic metal

16

GS 01R01B30-00E-E 8th edition, Feb. 19, 2009-00 All Rights Reserved. Copyright © 2004, Rota Yokogawa

Cutting ring

G or NPT thread approx. 135

approx. 113 approx. 60

F10.epsENG-018554

Cutting ring

G or NPT thread approx. 135

approx. 113 approx. 60

F11.epsENG-018555

Fig. 12 Version with inlet valve and inlet controller

Fig. 13 Version with outlet valve and back pressure controller

Page 17: General Model RAKD Specifications Small Metal Rotameter · 2011-04-25 · Model RAKD Small Metal Rotameter General Specifications A float is guided concentrically in a conic metal

17

GS 01R01B30-00E-E 8th edition, Feb. 19, 2009-00All Rights Reserved. Copyright © 2004, Rota Yokogawa

CONNeCtION tYPeSTable 10

Size a b c

Cone 31-51

Cone 52-53

Cone 31-53

Cone 31-51

ThreadG 1/4 G 3/8 G 1/4 G 1/4

1/4 NPT 3/8 NPT 1/4 NPT 1/4 NPT

INStaLLatION LeNGtHS DePeNDING ON CONNeCtION tYPe aND SIzeTable 11

L1 L2 L3

Process connection Size Cone 31-51 Cone 52-53 Cone 31-53 Cone 31-51

Cutting ring

6 mm 178 mm ------ 54.5 mm 164 mm

8 mm 172 mm ------ 51.5 mm 161 mm

10 mm 174 mm ------ 52.5 mm 162 mm

12 mm 174 mm 177 mm 52.5 mm 162 mm

Nozzle6 mm 182 mm ------ 56.5 mm 166 mm

8 mm 182 mm ------ 56.5 mm 166 mm

WeIGHtSTable 12

without valve with valve with controller

Weight approx. 600g approx. 1000g approx. 1800g

PLaNNING HINtS- The real working pressure has to be less than the specified pressure limit of the Rotameter.- Make sure that the wetted material is resistant to the medium.- Ambient and operation temperature has to be less than the specified maximum value.- If dirt accumulation is to be expected we recommend to install a bypass pipe.- To avoid float bouncing in case of gas application notice the recommendations of VDI/VDE 3513 Sheet 3.- To avoid mutual magnetic influence in case of a parallel design of several Rotameters take care that the distance between the tube middle axes is not less than 120 mm. The distance to other ferric materials should not be less than 60 mm.- The strength of external magnetic fields close by the Rotameter should be approximately 0mT.

Page 18: General Model RAKD Specifications Small Metal Rotameter · 2011-04-25 · Model RAKD Small Metal Rotameter General Specifications A float is guided concentrically in a conic metal

18

GS 01R01B30-00E-E 8th edition, Feb. 19, 2009-00 All Rights Reserved. Copyright © 2004, Rota Yokogawa

Page 19: General Model RAKD Specifications Small Metal Rotameter · 2011-04-25 · Model RAKD Small Metal Rotameter General Specifications A float is guided concentrically in a conic metal

19

GS 01R01B30-00E-E 8th edition, Feb. 19, 2009-00All Rights Reserved. Copyright © 2004, Rota Yokogawa

Page 20: General Model RAKD Specifications Small Metal Rotameter · 2011-04-25 · Model RAKD Small Metal Rotameter General Specifications A float is guided concentrically in a conic metal

20

GS 01R01B30-00E-E 8th edition, Feb. 19, 2009-00 All Rights Reserved. Copyright © 2004, Rota Yokogawa

Yokogawa has an extensive sales and distribution network. Please refer to the European website (www.yokogawa.com/eu) to contact your nearest representative.

Euroweg 23825 HD AMERSFOORTThe Netherlandswww.yokogawa.com/eu

YOKOGAWA ELECTRIC CORPORATIONWorld Headquarters9-32, Nakacho 2-chome, Musashino-shiTokyo 180-8750Japanwww.yokogawa.com

YOKOGAWA CORPORATION OF AMERICA2 Dart RoadNewnan GA 30265USAwww.yokogawa.com/us

YOKOGAWA ELECTRIC ASIA Pte. LTD.5 Bedok South RoadSingapore 469270Singaporewww.yokogawa.com/sg

YOKOGAWA CHINA CO. LTD.3F Tower D Cartelo Crocodile BuildingNo.568 West Tianshan Road Changing DistrictShanghai, Chinawww.yokogawa.com/cn

YOKOGAWA MIDDLE EAST B.S.C.(c)P.O. Box 10070, ManamaBuilding 577, Road 2516, Busaiteen 225Muharraq, Bahrainwww.yokogawa.com/bh

Subject to change without notice