G17 AIRD M023 DataSheet SferiRec FCR v2 · 2019. 8. 25. · → 16 ARINC 429 inputs (speed...
Transcript of G17 AIRD M023 DataSheet SferiRec FCR v2 · 2019. 8. 25. · → 16 ARINC 429 inputs (speed...
SferiRec® FCRFixed Crash Recorder
Fully equipped recorder models for medium and large aircraft platforms.
▪ Single Box: DAU and CPM integrated▪ Combined: Recording of voice, data, video and data link▪ Maintenance Recorder: Via data carrier
HENSOLDT88039 Friedrichshafen, Germany
+49 7545 [email protected]
This document is not contractual. Subject to change without notice. © 2019 HENSOLDT Sensors GmbH. HENSOLDT, its logo are registered trademarks. All rights reserved.
SferiRec®
FCR
SferiRec FCR 200(ARINC 404 Mounting)
Solid State Data Carrier (SSDC) (Option)
External Cockpit Area Microphone (Option)
Interfaces
→ 8 Audio Inputs (selectable 3,5 kHz to 12 kHz) for Intercom and CAM
→ 2 dual MIL-BUS (MIL-STD 1553B) Interfaces (one of them optional)
→ 4 Ethernet inputs (e.g. for image recording)→ 16 ARINC 429 inputs (speed selectable)→ 16 Discrete inputs, 7 Frequency inputs→ 4 Analogue inputs with
optional potentiometer supply → 4 HDLC I/Os→ 1 ARINC 717 / ARINC 615 / RS422 / RS485
data interface→ Interface to deployable
HENSOLDT Deployable Crash Recorder (DCR)→ 1 SSDC Interface
Features
→ Physically segregated tracks according ED-112A→ Data storage capacity 1 GB
(up to 16 GB optional)→ Ful� ls ED-112A crash survival requirements→ Underwater Locator Beacon (ULB)
mounted on front panel → Optional Recorder Independent Power Supply
(RIPS) compatible function for CVR
SferiRec® FCR Technical Data
SferiRec® FCR Dimensions(WxDxH)
124mm x 203mm x 155mm (excluding front elements)
SferiRec® FCR Mass approx. 3,85 kg max. (including ULB and RIPS)
SferiRec FCR Tray Mass approx. 0,90 kg (SEFCA Mounting Tray)
Operating Temperature Range -45°C to + 70°C
Connector Type ARINC 400/600 type or MIL 38999 on front panel
Power Input 2 x 28 VDC max. 25 Watt, acc. EN 2282
Bulk Erase /Encryption optional Bulk Erase Function via Central Clear Command or Encryption
Internal Sensors - One 3-axis G sensor, range +/- 10G per axis - One internal Real Time Clock (24 hour base)
Status Outputs two fail indication outputs 28VDC
Status Message via MIL-Bus RTU function or Maintenance Panel Indicator
Maintenance Recording MR Function via SSDC with a capacity from 1 GB up to 2 TB
Build Standards ED-112A, RTCA/DO160F, RTCA/DO-178C, RTCA/DO-254
Mounting SEFCA mounting or ARINC 404 mounting
CPM Quali� cation
Impact Shock 3400g
Crash Safety 3 shocks in 3 axes
Penetration Resistance 227 kg from 3 m
Low Temperature Fire 260 °C for 10 hours
High Temperature Fire 1100 °C for 60 min
Sea Water Immersion 30 days
Deep Sea Pressure 60 Mpa for 24 hours
Fluid Immersion Resistant against actual chemical � uids
Underwater Location Beacon (ULB)
37,5 kHz, 6.000m, 90 days according to TSO-C121b