 Hotfix 4 functions

 1

Project data

 2

 

SIMATIC HMI

 WinCC flexible 2007 Hotfix 4Functions

Readme

02/2008

Page 2: Functions Wincc Flexible 2007 Hf4

8/3/2019 Functions Wincc Flexible 2007 Hf4

http://slidepdf.com/reader/full/functions-wincc-flexible-2007-hf4 2/7

 Safety Guidelines

This manual contains notices you have to observe in order to ensure your personal safety, as well as to preventdamage to property. The notices referring to your personal safety are highlighted in the manual by a safety alertsymbol, notices referring only to property damage have no safety alert symbol. These notices shown below aregraded according to the degree of danger.

DANGER

indicates that death or severe personal injury will result if proper precautions are not taken.

WARNING

indicates that death or severe personal injury may result if proper precautions are not taken.

CAUTION

with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken.

CAUTION

without a safety alert symbol, indicates that property damage can result if proper precautions are not taken.

NOTICE

indicates that an unintended result or situation can occur if the corresponding information is not taken intoaccount.

If more than one degree of danger is present, the warning notice representing the highest degree of danger willbe used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating toproperty damage.

Qualified Personnel

The device/system may only be set up and used in conjunction with this documentation. Commissioning andoperation of a device/system may only be performed by qualified personnel. Within the context of the safety notesin this documentation qualified persons are defined as persons who are authorized to commission, ground andlabel devices, systems and circuits in accordance with established safety practices and standards.

Prescribed Usage

Note the following:

WARNING

This device may only be used for the applications described in the catalog or the technical description and onlyin connection with devices or components from other manufacturers which have been approved or recommended by Siemens. Correct, reliable operation of the product requires proper transport, storage,positioning and assembly as well as careful operation and maintenance.

Trademarks

All names identified by ® are registered trademarks of the Siemens AG. The remaining trademarks in thispublication may be trademarks whose use by third parties for their own purposes could violate the rights of theowner.

Disclaimer of LiabilityWe have reviewed the contents of this publication to ensure consistency with the hardware and softwaredescribed. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, theinformation in this publication is reviewed regularly and any necessary corrections are included in subsequenteditions.

Siemens AGAutomation and DrivesPostfach 48 4890327 NÜRNBERGGERMANY

Ⓟ 02/2008Copyright © Siemens AG .Technical data subject to change

 

Page 3: Functions Wincc Flexible 2007 Hf4

8/3/2019 Functions Wincc Flexible 2007 Hf4

http://slidepdf.com/reader/full/functions-wincc-flexible-2007-hf4 3/7

 

Table of contents

1 Hotfix 4 functions ....................................................................................................................................... 4

2 Project data ............................................................................................................................................... 6

WinCC flexible 2007 Hotfix 4 FunctionsReadme, 02/2008 3 

Page 4: Functions Wincc Flexible 2007 Hf4

8/3/2019 Functions Wincc Flexible 2007 Hf4

http://slidepdf.com/reader/full/functions-wincc-flexible-2007-hf4 4/7

 

Hotfix 4 functions 1New features in Hotfix 4

By installing this Hotfix you enable the integration of WinCC flexible in SIMOTION SCOUT .The integration of WinCC flexible in SIMOTION SCOUT is subject to certain restrictions,which are described in the chapter project data.

NoteNote on terms used:

•  Integrated mode: WinCC flexible runs in the context of SIMOTION SCOUT

•  Non-integrated operation: WinCC flexible runs as a stand-alone application. In it, you canprocess SIMOTION projects just as you would in integrated operation.

System requirements

The following requirements have to be met to ensure trouble-free operation of WinCC flexible integrated in SIMOTION SCOUT:

●  Memory: 4 GB●  Processor: Dual Core

Features

If you configure WinCC flexible in integrated operation in SIMOTION SCOUT, you areputting a high demand on the system memory. That is the reason why some UseCases arenot permitted in this operating mode. These restrictions are described in the chapter "projectdata".

You cannot execute non-permitted UseCases in non-integrated operation.

If a user works in integrated operation, there is a risk that memory usage may be pushed to

its limits. To signal this state in time, we have implemented the new function"Display memory usage in toolbar".

WinCC flexible 2007 Hotfix 4 Functions4 Readme, 02/2008

Page 5: Functions Wincc Flexible 2007 Hf4

8/3/2019 Functions Wincc Flexible 2007 Hf4

http://slidepdf.com/reader/full/functions-wincc-flexible-2007-hf4 5/7

Hotfix 4 functions 

Display of memory usage in toolbar of SIMOTION SCOUT

For fault-free integration of WinCC flexible, a new function monitors the memory usage of the

configuration PC during integrated operation of WinCC flexible in SIMOTION SCOUT.

Note

Data loss with memory overload

The message "Application will be terminated without save" will be displayed, if theapplication uses the entire memory allocated to this application by the Windows operatingsystem.

SIMOTION SCOUT will be terminated automatically and all changes after the last saveprocess will be lost.

Do not continue working on your WinCC flexible project in integrated operation in SIMOTIONSCOUT.

Open the project directly in WinCC flexible and continue working in non-integrated operation. Operation of button "Memory usage"

●  If you move the mouse cursor over the button "Memory usage", you will see a tooltip thatindicates the actual state of memory usage in percent.

●  If you click on the button "Memory usage", you will see the actual state of the memoryusage in a message box.

●  In case of memory overload, proceed as follows:

 –   Acknowledge this message: "Application will be terminated without save".

 –   Exit the DOS box with confirmation by pressing any key. –   Open the project in WinCC flexible and continue working on the project in non-

integrated operation.

WinCC flexible 2007 Hotfix 4 FunctionsReadme, 02/2008 5 

Page 6: Functions Wincc Flexible 2007 Hf4

8/3/2019 Functions Wincc Flexible 2007 Hf4

http://slidepdf.com/reader/full/functions-wincc-flexible-2007-hf4 6/7

 

Project data 2Features of integrated operation

Note the following restrictions for integrated operation of WinCC flexible inSIMOTION SCOUT.

●  If you try to open a project with HMI percentage in integrated operation, you will receivean error message if the versions of SIMOTION Scout and/or WinCC flexible do not

correspond to a valid release combination.●  Only the following applications are to run simultaneously:

 –   2x SIMOTION SCOUT

 –   1x SIMOTION SCOUT + 1x WinCC flexible

●  Conversion of projects in STAND-ALONE mode only.

 –   Cancel the conversion of the WinCC flexible project after opening a project of theprevious version of WinCC flexible in SIMOTION SCOUT.

 –   Copy devices and mass operations (copying several screens) may take place inSTAND-ALONE operation only.

●  Only images which do not contain faceplate instances may be placed in the library.

●  "Small" projects may be processed in integrated operation.

●  You can process new projects in integrated operation during the initial phase; projectconsistency cannot be ensured as soon as the project data has been exceeded and youwill have to continue working on the project in STAND-ALONE mode.

●  Large projects may be processed in STAND-ALONE mode only.

Note

The new function "Memory monitoring" in the SIMOTION SCOUT toolbar will support youin not exceeding the capacity of your configuration PC.

The message "Application will be terminated without save" will be displayed, if the

application uses the entire memory allocated to this application by the Windows operatingsystem.

WinCC flexible 2007 Hotfix 4 Functions6 Readme, 02/2008

Page 7: Functions Wincc Flexible 2007 Hf4

8/3/2019 Functions Wincc Flexible 2007 Hf4

http://slidepdf.com/reader/full/functions-wincc-flexible-2007-hf4 7/7

Project data 

Objects and actions

Objects Maximum numberHMI devices 3 PC systems (offers best functionality)

or 

2 MP panels

Screens 40 per device with approximately 50 objects per screen

Symbols (CPU variables) 500 per device

Text / image lists 50 per device

Runtime languages 5 per device (means five times as many texts and images)

Number of images in the project 30 per device, 100 kB per language

Number of texts in the project 300 per device, 1 kB per language

Recipes 10 recipes per device with 20 entries each

Logs 2 logs per device

Scripts 50 scripts with approximately 10 lines in the project

Actions Number

Delete devices 3x

Drag devices to library STAND-ALONE mode only

Drag devices from library into project STAND-ALONE mode only

Copy and insert device STAND-ALONE only

Create TO screens for a device For 6 axes (= 36 screens)Copy TO screen of first device and insert in seconddevice

3x

Save and compile all Always

Reconnect symbols Cross reference lists

WinCC flexible 2007 Hotfix 4 FunctionsReadme, 02/2008 7