FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf ·...

156
C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration Manual

Transcript of FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf ·...

Page 1: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

C122-E155-04EN

FUJITSU Server

PRIMEQUEST 1000 Series SAN Boot Environment Configuration Manual

Page 2: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

i

Preface This manual is a revised version of APPENDIX D Configuring the SAN Boot Environment from the

PRIMEQUEST 1000 Series Installation Manual (C122-E107EN). The manual describes procedures for

installing the SAN boot environment and provides the latest information including notes on design.

The manual describes the procedures applicable to the following UEFI driver versions:

FC SAN boot: Procedures for setting UEFI driver version 4.00a1 or earlier and version 4.12a7 or later

The manual is intended for system administrators.

For details on the regulatory compliance statements and safety precautions, see the PRIMEQUEST 1000 Series

Safety and Regulatory Information (C122-E115EN).

Errata and addenda for the manual

PRIMEQUEST 1000 Series Errata and Addenda (C122-E119EN) provides errata and addenda for the manual.

Read the PRIMEQUEST 1000 Series Errata and Addenda (C122-E119EN) thoroughly in reference to the

manual.

For Safe Operation

How to use this manual

This manual contains important information about the safe use of this product. Read the manual thoroughly to

understand the information in it before using this product. Be sure to keep this manual in a safe and convenient

location for quick reference.

Fujitsu makes every effort to prevent users and bystanders from being injured and to prevent property damage.

Be sure to use the product according to the instructions in the manual.

About this product

This product is designed and manufactured for standard applications. Such applications include, but are not

limited to, general office work, personal and home use, and general industrial use. The product is not intended

for applications that require extremely high levels of safety to be guaranteed (referred to below as

"safety-critical" applications). Use of the product for a safety-critical application may present a significant risk

of personal injury and/or death. Such applications include, but are not limited to, nuclear reactor control, aircraft

flight control, air traffic control, mass transit control, medical life support, and missile launch control.

Customers shall not use the product for a safety-critical application without guaranteeing the required level of

safety. Customers who plan to use the product in a safety-critical system are requested to consult the Fujitsu

sales representatives in charge.

Storage of accessories

Keep the accessories in a safe place because they are required for server operation.

Page 3: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

ii

Organization and Notation of This Manual

This section describes the following topics:

- Organization of this manual

- Manuals for the PRIMEQUEST 1000 series

- Related manuals

- Abbreviations

- Notation

- Notation for the CLI (command line interface)

- Notes on notations

- Alert messages

- Product operating environment

- Trademarks

Organization of this manual

This manual is organized as follows.

CHAPTER 1 Configuring the SAN Boot Environment

Chapter 1 describes the procedure for installing the SAN boot environment and provides notes on design.

CHAPTER 2 Settings on the Fiber Channel Card (FC Card)

Chapter 2 describes the settings to be made on the FC card to start the system from an LUN of the SAN

storage unit in the FC SAN boot environment.

CHAPTER 3 Installing Windows

Chapter 3 describes how to install Windows in the FC SAN boot environment.

CHAPTER 4 Installing RHEL

Chapter 4 describes how to install Red Hat Enterprise Linux (RHEL) in the FC SAN boot environment.

CHAPTER 5 Installing VMware

Chapter 5 provides a link to the guides provided by VMware, Inc.

Page 4: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

iii

Manuals for the PRIMEQUEST 1000 series

The following manuals have been prepared to provide you with the information necessary to use the

PRIMEQUEST 1000 series.

You can access HTML versions of these manuals at the following sites:

Japanese-language site: http://jp.fujitsu.com/platform/server/primequest/manual/

Global site: http://jp.fujitsu.com/platform/server/primequest/manual-e/

Title Description Manual code

PRIMEQUEST 1000 Series

Getting Started Guide

Describes what manuals you should read and how to

access important information after unpacking the

PRIMEQUEST 1000 series server. (This manual

comes with the product.)

C122-E114XA

PRIMEQUEST 1000 Series

Safety and Regulatory

Information

Contains important information required for using the

PRIMEQUEST 1000 series safely. (This manual

comes with the product.)

C122-E115XA

PRIMEQUEST 1000 Series

Errata and Addenda

Provides errata and addenda for the PRIMEQUEST

1000 series manuals. This manual will be updated as

needed.

C122-E119EN

PRIMEQUEST 1000 Series

General Description

Describes the functions and features of the

PRIMEQUEST 1000 series.

C122-B022EN

SPARC

Enterprise/PRIMEQUEST

Common Installation

Planning Manual

Provides the necessary information and concepts you

should understand for installation and facility planning

for SPARC Enterprise and PRIMEQUEST

installations.

C120-H007EN

PRIMEQUEST 1000 Series

Hardware Installation

Manual

Includes the specifications of and the installation

location requirements for the PRIMEQUEST 1000

series.

C122-H004EN

PRIMEQUEST 1000 Series

Installation Manual

Describes how to set up the PRIMEQUEST 1000

series server, including the steps for installation

preparation, initialization, and software installation.

C122-E107EN

PRIMEQUEST 1000 Series

User Interface Operating

Instructions

Describes how to use the Web-UI and UEFI to assure

proper operation of the PRIMEQUEST 1000 series

server.

C122-E109EN

Page 5: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

iv

Title Description Manual code

PRIMEQUEST 1000 Series

Administration Manual

Describes how to use tools and software for system

administration and how to maintain the system

(component replacement and error notification).

C122-E108EN

PRIMEQUEST 1000 Series

Tool Reference

Provides information on operation methods and

settings, including details on the MMB, PSA, and

UEFI functions.

C122-E110EN

PRIMEQUEST 1000 Series

Message Reference

Lists the messages that may be displayed when a

problem occurs during operation and describes how to

respond to them.

C122-E111EN

PRIMEQUEST 1000 Series

REMCS Installation Manual

Describes REMCS service installation and operation. C122-E120EN

PRIMEQUEST 1000 Series

Glossary

Defines the PRIMEQUEST 1000 series related terms

and abbreviations.

C122-E116EN

PRIMEQUEST 1000 Series

SAN Boot Environment

Configuration Manual

Provides a revised version of APPENDIX D

Configuring the SAN Boot Environment from the

PRIMEQUEST 1000 Series Installation Manual

(C122-E107EN). The manual describes procedures for

installing the SAN boot environment and provides the

latest information including notes on design.

C122-E155EN

Related manuals

The following manuals relate to the PRIMEQUEST 1000 series.

You can access these manuals at the following site:

http://jp.fujitsu.com/platform/server/primequest/manual-e/

Contact your sales representative for inquiries about the ServerView manuals.

Title Description Manual code

ServerView Suite

ServerView Operations

Manager Quick Installation

(Windows)

Describes how to install and start ServerView

Operations Manager in a Windows environment.

None

Page 6: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

v

Title Description Manual code

ServerView Suite

ServerView Operations

Manager Quick Installation

(Linux)

Describes how to install and start ServerView

Operations Manager in a Linux environment.

None

ServerView Suite

ServerView Installation

Manager

Describes the installation procedure using ServerView

Installation Manager.

None

ServerView Suite

ServerView Operations

Manager Server

Management

Provides an overview of server monitoring using

ServerView Operations Manager, and describes the

user interface of ServerView Operations Manager.

None

ServerView Suite

ServerView RAID

Management User Manual

Describes RAID management using ServerView RAID

Manager

None

ServerView Suite

Basic Concepts

Describes the basic concepts of ServerView Suite. None

ServerView Operations

Manager

Installation ServerView

Agents for Linux

Describes installation and update installation of

ServerView Linux Agent.

None

ServerView Operations

Manager

Installation ServerView

Agents for Windows

Describes installation and update installation of

ServerView Windows Agent.

None

ServerView Mission Critical

Option User Manual

Describes the necessary functions unique to

PRIMEQUEST (notification via the MMB, hot

replacement command) and ServerView Mission

Critical Option (SVmco), which is required for

supporting these functions.

Also includes explanation of ServerView

Mission Critical Option for VM (SVmcovm)

required for VMware vSphere 5 server monitor.

None

Page 7: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

vi

Title Description Manual code

ServerView RAID Manager

VMware vSphere ESXi 5

Installation Guide

ServerView Describes the installation and

settings required to use ServerView RAID

Manager on the VMware vSphere ESXi 5 server.

None

MegaRAID SAS Software Provides technical information on using array

controllers.

Refer to the manual from the SVS-DVD2

supplied with the product or from the following URL:

The Fujitsu Technology Solutions manuals server

http://manuals.ts.fujitsu.com/

None

MegaRAID SAS Device

Driver Installation

Provides technical information on using array

controllers.

Refer to the manual from the SVS-DVD2

supplied with the product or from the following URL:

The Fujitsu Technology Solutions manuals server

http://manuals.ts.fujitsu.com/

None

Modular RAID Controller

Installation Guide

Provides technical information on using array

controllers.

Refer to the manual from the SVS-DVD2

supplied with the product or from the following URL:

The Fujitsu Technology Solutions manuals server

http://manuals.ts.fujitsu.com/

None

Page 8: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

vii

Abbreviations

This manual uses the following product name abbreviations.

Formal product name Abbreviation

Red Hat(R) Enterprise Linux(R) 5 (for Intel64)

Red Hat(R) Enterprise Linux(R) 5 (for x86)

Linux

RHEL5, RHEL

Red Hat(R) Enterprise Linux(R) 6 (for Intel64)

Red Hat(R) Enterprise Linux(R) 6 (for x86)

Linux

RHEL6, RHEL

Microsoft(R) Windows Server(R) 2003, Standard Edition

Microsoft(R) Windows Server(R) 2003, Enterprise Edition

Microsoft(R) Windows Server(R) 2003, Datacenter Edition

Microsoft(R) Windows Server(R) 2003, Standard x64 Edition

Microsoft(R) Windows Server(R) 2003, Enterprise x64 Edition

Microsoft(R) Windows Server(R) 2003, Datacenter x64 Edition

Microsoft(R) Windows Server(R) 2003 R2, Standard Edition

Microsoft(R) Windows Server(R) 2003 R2, Enterprise Edition

Microsoft(R) Windows Server(R) 2003 R2, Datacenter Edition

Microsoft(R) Windows Server(R) 2003 R2, Standard x64 Edition

Microsoft(R) Windows Server(R) 2003 R2, Enterprise x64 Edition

Microsoft(R) Windows Server(R) 2003 R2, Datacenter x64 Edition

Windows

Windows Server 2003

Microsoft(R) Windows Server(R) 2008 Standard

Microsoft(R) Windows Server(R) 2008 Enterprise

Microsoft(R) Windows Server(R) 2008 Datacenter

Microsoft(R) Windows Server(R) 2008 R2 Standard

Microsoft(R) Windows Server(R) 2008 R2 Enterprise

Microsoft(R) Windows Server(R) 2008 R2 Datacenter

Windows

Windows Server 2008

Microsoft(R) Windows Server(R) 2012 Datacenter

Microsoft(R) Windows Server(R) 2012 Standard

Windows

Windows Server 2012

VMware vSphere(R) 4 VMware, vSphere 4.x,

VMware 4.x

VMware vSphere(R) 5 VMware, vSphere 5.x,

VMware 5.x

VMware(R) ESX(R) 4 ESX, ESX 4.x

VMware(R) ESXi(TM) 5 ESXi, ESXi 5.x

Novell(R) SUSE(R) LINUX Enterprise Server 11 Service Pack 2 SLES11 SP2

Page 9: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

viii

Notation

This manual uses the following fonts and symbols to express specific types of information.

Font or

symbol

Meaning Example

italics Title of a manual that you should refer to See the PRIMEQUEST 1000 Series

Installation Manual (C122-E107EN).

[ ] Window names as well as the names of

buttons, tabs, and drop-down menus in

windows are enclosed in brackets.

Click the [OK] button.

Notation for the CLI (command line interface)

The following notation is used for commands.

Command syntax

The following notation is used for commands.

- Variables requiring the entry of a value are enclosed in angle brackets < >.

- Optional elements are enclosed in brackets [ ].

- Options for optional keywords are grouped in | (stroke) separated lists enclosed in brackets [ ].

- Options for required keywords are grouped in | (stroke) separated lists enclosed in braces { }.

Command syntax is written in a box.

Remarks

The command output shown in the PDF manuals may include line feeds at places where there is no line feed

symbol (\ at the end of the line).

Notes on notations

- In this manual, the Management Board and MMB firmware are abbreviated as "MMB."

- In this manual, IOBs and GSPBs (LIOBs and LGSPBs within partitions) are collectively referred to as IO

Units.

- Screenshots contained in this manual may differ from the actual product screen displays.

- The IP addresses, configuration information, and other such information appearing in this manual are display

examples and differ from that displayed during actual operation.

Page 10: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

Alert messages

This manual uses the following alert messages to prevent users and bystanders from being injured and to

prevent property damage.

This indicates a hazardous (potentially dangerous) situation that is likely to result

in death or serious personal injury if the user does not perform the procedure

correctly.

This indicates a hazardous situation that could result in minor or moderate personal

injury if the user does not perform the procedure correctly. This also indicates that

damage to the product or other property may occur if the user does not perform the

procedure correctly.

This indicates information that could help the user use the product more

efficiently.

Alert messages in the text

An alert statement follows an alert symbol. An alert statement is indented on both ends to distinguish it from

regular text. Similarly, one space line is inserted before and after the alert statement.

Only Fujitsu certified service engineers should perform the following tasks on this

product and the options provided by Fujitsu. Customers must not perform these tasks

under any circumstances. Otherwise, electric shock, injury, or fire may result.

- Newly installing or moving equipment

- Removing the front, rear, and side covers

- Installing and removing built-in options

- Connecting and disconnecting external interface cables

- Maintenance (repair and periodic diagnosis and maintenance)

The List of important alert items tables list important alert items.

Product operating environment

This product is a computer intended for use in a computer room environment. For details on the product

operating environment, see the following manual:

PRIMEQUEST 1000 Series Hardware Installation Manual (C122-H004EN)

ix

Page 11: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

x

Notes

- If you have a comment or request regarding this manual, or if you find any part of this manual unclear, please

take a moment to share it with us by filling in the form at the following webpage, stating your points specifically,

and sending the form to us:

http://jp.fujitsu.com/platform/server/primequest/contact/

- The contents of this manual may be revised without prior notice.

The PDF file of this manual is intended for display using Adobe® Reader® in single page viewing mode at

100% zoom.

- The PRIMEQUEST 1800E2/1800E model supports only 200 V power supply.

Trademarks

- Microsoft, Windows, and Windows Server are trademarks or registered trademarks of Microsoft Corporation

in the United States and/or other countries.

- Linux is a registered trademark of Linus Torvalds.

- Red Hat, the Shadowman logo and JBoss are registered trademarks of Red Hat, Inc. in the U.S. and other

countries.

- Intel and Xeon are trademarks or registered trademarks of Intel Corporation.

- Ethernet is a registered trademark of Fuji Xerox Co., Ltd. in Japan and is a registered trademark of Xerox

Corp. in the United States and other countries.

- VMware is a trademark or registered trademark of VMware, Inc. in the United States and other countries.

- Novell and SUSE Linux Enterprise Server are trademarks of Novell, Inc.

- Xen is a trademark or registered trademark of Citrix Systems, Inc. or its subsidiaries in the United States and

other countries.

- Other company names and product names are the trademarks or registered trademarks of their respective

owners.

- Trademark indications (TM, (R)) are omitted for some system and product names in this manual.

Page 12: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

Safety Precautions

List of important alert items

The following tables list the important alert items contained in this manual.

Only field engineers should perform the following tasks on this product and the options

provided by Fujitsu. Customers must not perform these tasks under any circumstances.

Otherwise, electric shock, injury, or fire may result.

Work

category

Warning Location

Setup - Newly installing or moving equipment

- Removing the front, rear, and side covers

- Installing and removing built-in options

- Connecting and disconnecting external interface cables

- Maintenance (repair and periodic diagnosis and maintenance)

CHAPTER 1

Configuring the

SAN Boot

Environment

xi

Page 13: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

Warning labels

The following warning labels are affixed to this product. These labels are intended for the users of this product.

Never remove the warning labels.

* The label is affixed at either location.

Warning label location (PRIMEQUEST 1800E2/1800E rear)

xiiWarning label location (PRIMEQUEST 1800E2/1800E rear) (IOBs removed)

Page 14: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

Warning label location (PCI_Box)

xiii

Page 15: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

Notes on Handling the Product

Adding optional products

For stable operation of the PRIMEQUEST 1000 series server, use only a Fujitsu certified optional product as an

added option.

Note that the PRIMEQUEST 1000 series server is not guaranteed to operate with any optional product not

certified by Fujitsu.

Maintenance

Only Fujitsu certified service engineers should perform the following tasks on this product and

the options provided by Fujitsu. Customers must not perform these tasks under any circumstances.

Otherwise, electric shock, injury, or fire may result.

- Newly installing or moving equipment

- Removing the front, rear, and side covers

- Installing and removing built-in options

- Connecting and disconnecting external interface cables

- Maintenance (repair and periodic diagnosis and maintenance)

Only Fujitsu certified service engineers should perform the following tasks on this product and

the options provided by Fujitsu. Customers must not perform these tasks under any circumstances.

Otherwise, product failure may result.

- Unpacking an optional Fujitsu product, such as an optional adapter, delivered to the customer

Modifying or recycling the product

Modifying this product or recycling a secondhand product by overhauling it without prior

approval may result in personal injury to users and/or bystanders or damage to the product and/or

other property.

xiv

Page 16: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

xv

Note on erasing data from hard disks when disposing of the product or

transferring it

Disposing of this product or transferring it as is may enable third parties to access the data on the hard disk and

use it for unforeseen purposes. To prevent the leakage of confidential information and important data, all of the

data on the hard disk must be erased before disposal or transfer of the product.

However, it can be difficult to completely erase all of the data from the hard disk. Simply initializing

(reformatting) the hard disk or deleting files on the operating system is insufficient to erase the data, even

though the data appears at a glance to have been erased. This type of operation only makes it impossible to

access the data from the operating system. Malicious third parties can restore this data.

If you save your confidential information or other important data on the hard disk, you should completely erase

the data, instead of simply carrying out the aforementioned operation, to prevent the data from being restored.

To prevent important data on the hard disk from being leaked when the product is disposed of or transferred,

you will need to take care to erase all the data recorded on the hard disk on your own responsibility.

Furthermore, if a software license agreement restricts the transfer of the software (operating system and

application software) on the hard disk in the server or other product to a third party, transferring the product

without deleting the software from the hard disk may violate the agreement. Adequate verification from this

point of view is also necessary.

Support and Service

SupportDesk (available only in Japan, for a fee)

For stable system operation, we recommend concluding our SupportDesk agreement, which provides a

maintenance and operation support service. SupportDesk agreement customers receive a same-day

response service for hardware problems. They are eligible for regular checkups, remote notification of

potential-failure predictions, and information on system problems. Moreover, they can avail themselves of

other services such as troubleshooting support by phone for hardware and software problems, and access

to operation support information from a dedicated website for our customers. For details, see "Product

support" on the SupportDesk homepage

(http://jp.fujitsu.com/solutions/support/sdk/index.html).

Product and service inquiries

For all product use and technical inquiries, contact the store where you purchased the product, or a Fujitsu

sales representative or systems engineer (SE). If you do not know the appropriate contact address for

inquiries about the PRIMEQUEST 1000 series, use the Fujitsu contact line.

Page 17: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

xvi

Fujitsu contact line

We accept Web inquiries. For details, visit our website:

https://www-s.fujitsu.com/global/contact/computing/PRMQST_feedback.html

Warranty

If a component failure occurs during the warranty period, we will repair it free of charge in accordance

with the terms of the warranty agreement. For details, see the warranty.

Before requesting a repair

If a problem occurs with the product, confirm the problem by referring to 11.2 Troubleshooting in the

PRIMEQUEST 1000 Series Administration Manual (C122-E108EN). If the error recurs, contact your sales

representative or a field engineer.

Confirm the model name and serial number shown on the label affixed to the right front of the device and

report it. Also check any other required items beforehand according to 11.2 Troubleshooting in the

PRIMEQUEST 1000 Series Administration Manual (C122-E108EN).

The system settings saved by the customer will be used during maintenance.

Page 18: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

xvii

Revision History Edition Date Revised location

(type) (*1)

Description

01 2011-02-01 All pages

(appropriated and

revised)

- Appropriated all the pages of APPENDIX D Configuring

the SAN Boot Environment from the PRIMEQUEST 1000

Series Installation Manual (C122-E107EN) and revised the

pages.

02 2011-05-31 All pages - Added the procedure for setting UEFI driver version 4.12a7

or later.

04 2012-12-21 All pages - Added descriptions about Windows Server 2012.

- Added descriptions about installing SLES11 SP2.

*1 Item numbers in the "Revised location" column refer to those in the latest edition of the document.

However, a number marked with an asterisk (*) denotes an item in a previous edition of the document.

This manual shall not be reproduced or copied without the permission of Fujitsu Limited.

Copyright 2010 - 2012 FUJITSU LIMITED

Page 19: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

xviii

Contents

CHAPTER 1 Configuring the SAN Boot Environment ........................................................................1

1.1 Preparing to Configure the SAN Boot Environment ...................................................................1

1.2 SAN Boot Environment Configuration Flow ..............................................................................2

1.3 Notes on SAN Boot Environment Design ...................................................................................5

1.3.1 Notes on system design ...............................................................................................................5

1.3.2 Notes on system installation ........................................................................................................5

1.3.3 Notes on system operation...........................................................................................................6

1.4 ETERNUS Connection Settings ..................................................................................................7

1.4.1 Settings for Windows ..............................................................................................................7

1.4.2 Settings for Linux ..................................................................................................................10

1.4.3 Settings for VMware ESX.....................................................................................................11

CHAPTER 2 Settings on the Fiber Channel Card (FC Card) .............................................................14

2.1 UEFI Driver Settings on the FC Card........................................................................................14

2.1.1 Selecting the method of making settings for the FC card (1) ....................................................15

2.1.2 Selecting the method of making settings for the FC card (2) ....................................................17

2.2 Procedure for Setting UEFI Driver Version 4.00a1 or Earlier on the FC Card .........................20

2.2.1 Displaying the driver list ...........................................................................................................20

2.2.2 Displaying the HBA list ............................................................................................................21

2.2.3 Starting the HBA setup utility ...................................................................................................23

2.2.4 Displaying the HBA setup utility ..............................................................................................24

2.2.5 Acquiring an HBA WWN .........................................................................................................25

2.2.6 Initializing the HBA setting.......................................................................................................26

2.2.7 Enabling BIOS...........................................................................................................................29

2.2.8 Speed and Topology settings .....................................................................................................31

2.2.9 Boot device setting ....................................................................................................................39

2.2.10 Applying settings.....................................................................................................................47

2.2.11 Recording the WWN of the FC port........................................................................................47

2.3 Procedure for Setting UEFI Driver Version 4.12a7 or Later on the FC Card............................49

2.3.1 Displaying the Device Manager ................................................................................................49

2.3.2 Starting the HBA setup utility ...................................................................................................50

2.3.3 Acquiring an HBA WWN .........................................................................................................52

2.3.4 Selecting an HBA......................................................................................................................53

2.3.5 Initializing the HBA setting.......................................................................................................55

Page 20: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

xix

2.3.6 Enabling BIOS...........................................................................................................................57

2.3.7 Speed and Topology settings .....................................................................................................59

2.3.8 Boot device setting ....................................................................................................................68

2.3.9 Applying settings.......................................................................................................................80

2.3.10 Recording the WWN of the FC port........................................................................................82

CHAPTER 3 Installing Windows .......................................................................................................84

3.1 Installing Windows Server 2008/2012.......................................................................................84

3.1.1 Preparing for Windows Server 2008/2012 installation..............................................................84

3.1.2 Installing the OS and bundled software.....................................................................................88

3.1.3 Various post-installation settings...............................................................................................89

3.1.4 Advanced settings of driver parameters.....................................................................................90

3.1.5 For a multipath configuration ....................................................................................................91

3.2 Installing Windows Server 2003 SP2 ........................................................................................92

3.2.1 Preparing to install Windows Server 2003 SP2.........................................................................92

3.2.2 Preparing for the FC card driver................................................................................................92

3.2.3 Installing the OS and bundled software.....................................................................................93

3.2.4 Installing HBAnyware...............................................................................................................96

3.2.5 Making various settings after installation..................................................................................97

3.2.6 Advanced settings of driver parameters.....................................................................................98

3.2.7 For a multipath configuration ....................................................................................................99

3.3 Changing and Checking the Setting of Detailed FC Card Information ...................................100

3.3.1 Setting driver parameters (for HBAnyware)........................................................................100

3.4 Checking Registry Information................................................................................................101

3.4.1 Checking the TimeOutValue setting value..............................................................................102

3.5 Completing the Windows Installation .....................................................................................102

CHAPTER 4 Installing RHEL ..........................................................................................................103

4.1 Installing RHEL.......................................................................................................................103

4.1.1 Preparing for RHEL installation..............................................................................................103

4.1.2 Installing the OS and bundled software...................................................................................103

4.1.3 Making various settings after installation................................................................................105

4.1.4 Installing HBAnyware.............................................................................................................105

4.2 Using the Built-in Disk with RHEL.........................................................................................108

4.2.1 Checking the disk connection state before mounting the built-in disk ....................................108

4.2.2 Mounting the built-in disk .......................................................................................................108

4.2.3 Configuring the RAID of the built-in disk (when using the SAS array disk unit)...................108

4.2.4 Configuring the UEFI..............................................................................................................109

Page 21: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

xx

4.2.5 Using a LUN of a non-boot disk..............................................................................................118

4.2.6 Using other disks .....................................................................................................................118

CHAPTER 5 Installing SUSE Linux Enterprise Server 11 Service Pack 2 ......................................119

5.1 Installing SLES11 SP2 ............................................................................................................119

5.1.1 Preparing for SLES11 SP2 installation....................................................................................119

5.1.2 Installing the OS and bundled software...................................................................................119

5.1.3 Making various settings after installation................................................................................121

5.2 Using the Built-in Disk with SLES11 SP2 ..............................................................................123

5.2.1 Checking the disk connection state before mounting the built-in disk ....................................123

5.2.2 Mounting the built-in disk .......................................................................................................123

5.2.3 Configuring the RAID of the built-in disk (when using the SAS array disk unit)...................123

5.2.4 Configuring the UEFI..............................................................................................................124

CHAPTER 6 Installing VMware ......................................................................................................134

Page 22: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

CHAPTER 1 Configuring the SAN Boot

Environment This chapter describes the procedure for installing the SAN boot environment and provides notes on design.

The chapter assumes that an ETERNUS model is used as the SAN storage unit.

Only field engineers should perform the following tasks on this product and the options provided

by Fujitsu. Customers must not perform these tasks under any circumstances. Otherwise, electric

shock, injury, or fire may result.

- Newly installing or moving equipment

- Removing the front, rear, and side covers

- Installing and removing built-in options

- Connecting and disconnecting external interface cables

- Maintenance (repair and periodic diagnosis and maintenance)

1.1 Preparing to Configure the SAN Boot Environment

The following hardware and software are required to configure the SAN boot environment.

Required hardware

PRIMEQUEST 1000 series main unit

Fibre Channel card (FC card) or converged network adapter.

The main unit for performing a SAN boot must have a mounted FC card (8 Gbps) or converged network

adapter.

FC switch

PC for the setup of the SAN storage unit (ETERNUS) and FC switch (If the PC requirements are

satisfied, it can also be used as another console such as the MMB console. For details, see the manual for

each device.)

1

Page 23: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2

Remarks

For information on the FC card and converged network adapter, contact the distributor where you purchased

your product, or your sales representative.

Required software

For details on the operating systems that support the SAN boot, the FC card driver/firmware, and the FC card

firmware version, visit the following website.

Also, the latest driver and firmware can be obtained from the following website. For a multipath configuration,

the ETERNUS multipath driver is required.

- Driver/firmware website

http://jp.fujitsu.com/platform/server/primequest/download-e/

Acquire the drivers and utilities for the FC card or converged network adapter from the above website.

For a multipath configuration, the ETERNUS multipath driver is required.

1.2 SAN Boot Environment Configuration Flow This section describes the configuration flow for SAN boot environment. Follow steps 1 to 4 below to

configure the SAN boot environment.

Notes

Use a single path configuration (connection with only one FC cable) until the installation of the operating

system and multipath driver is completed.

After installing the operating system and multipath driver, connect the FC cable to restore the original

state. Then, power on the partition of the PRIMEQUEST 1000 series server again.

Register the LUN that is the destination of operating system installation in all of the HBAs to be used for

starting the system.

Before turning on the power to the partition of the PRIMEQUEST 1000 series server, confirm that the

SAN storage where the operating system is to be stored and the FC switch are completely ready.

1. Designing the SAN boot environment

Create a drawing for FC cabling between the SAN storage unit and the PRIMEQUEST 1000 series server

in which the SAN boot environment is to be configured. Also create a zone design drawing.

Design the RAID (LUN_R) settings and partition (LUN) for the SAN storage that stores the target

operating system of SAN boot.

Page 24: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

3

Check 1.3 Notes on SAN Boot Environment Design.

2. Making the settings for the PRIMEQUEST 1000 series server

Change the UEFI setting of the PRIMEQUEST 1000 series server and the HBA UEFI/extended BIOS

setting of the FC card or converged network adapter.

Record the WWN for each FC port. Also record the WWNN as required.

3. Making the settings for the SAN environment

According to the drawing for FC cabling designed in step 1, install the SAN storage and FC switch and

connect them with cables.

Based on the RAID setting, partition design, and zone information designed in step 1 and on the WWN

information written down in step 2, make the settings for the SAN storage and FC switches.

In the setting of the HBA UEFI/extended BIOS of the FC card / converged network adapter included in

the PRIMEQUEST 1000 series server, search for the WWN of the connection destination SAN storage

and set it.

Page 25: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

4

4. Installing the OS and bundled software

Use SVIM to install the OS and bundled software.

Install the multipath driver as required.

According to the drawing for FC cabling designed in step 1, connect the PRIMEQUEST 1000 series

server with the SAN storage/FC switch.

Register the boot disk (LUN that is the destination of operating system installation) in all of the HBAs to

be used for starting the system.

Specify the priority of the boot devices with the UEFI of the PRIMEQUEST 1000 series server.

Page 26: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

5

1.3 Notes on SAN Boot Environment Design This section provides notes on designing the SAN boot environment.

1.3.1 Notes on system design

1.3.2 Notes on system installation

1.3.3 Notes on system operation

1.3.1 Notes on system design

Note the following points when designing the system.

Traffic on the FC may be maximized for some software used. Be sure to measure its performance on a

system such as a pseudo system before installing it.

For SAN storage, the boot disk to be assigned for each server must be configured so that it is exclusively

accessed from other servers. This is done by zoning or masking LUNs (LUN) or combining them. (In a

SAN boot environment, boot disk LUNs (LUN) must be such that servers and storage have a one-to-one

correspondence.)

Restriction: The following Windows operating systems can be installed in the SAN boot environment.

- Windows Server 2003 SP2

- Windows Server 2003 R2 SP2

- Windows Server 2008 SP2

- Windows Server 2008 R2

- Windows Server 2008 R2 SP1

- Windows Server 2012

1.3.2 Notes on system installation

Keep the following points in mind when installing the system.

For Notes on ServerView Suite, contact the distributor where you purchased your product, or your sales

representative.

Every disk except the boot disk must not be visible during installation of the operating system.

Disconnect all disks other than the installation destination disk. For a multipath configuration, change it to

a single-path configuration (only one FC cable connected). Also, the settings on the ETERNUS side must

be such that only the boot disk is visible.

For details on settings on the ETERNUS side, see 1.4 ETERNUS Connection Settings.

If you install the operating system while multiple HDDs are connected, a subsequent boot of the operating

system may require the HDDs that were connected at the installation time. Therefore, at this time, connect

only the installation destination HDD, and do not connect other HDDs.

Page 27: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

6

1.3.3 Notes on system operation

Keep the following points in mind when operating the system.

Be sure to confirm that the SAN storage and FC switch are completely in the Ready state.

Use the MMB Web-UI to set the time period until the power-on of the partition.

When the partition is started, the boot disk may not be found. In this case, try partition reset from the UEFI.

Record the dates and times of server switching (FC card replacement and converged network adapter

replacement. Including move.) on separate media. Prepare this media in case the possibly faulty part of the

hardware can no longer be located in an event log primary analysis, at a hardware failure, or at the occurrence

of another problem.

When the FC card or the converged network adapter has been replaced with a maintenance part, the HBA

UEFI/expansion BIOS must be reset. Also, the SAN storage unit must be reset.

In the SAN boot environment, OS boot may fail depending on the quality of the FC transmission path. In such

a case, use the FC switch and SAN storage unit to check the alarm or system status and identify the faulty part.

Then, select [Reset] from the [Power Control] window of the MMB Web-UI to restart the system.

In a Linux environment, a SAN boot in a multipath configuration may be performed. To start up in Rescue

mode and automatically mount the ETERNUS disk in such cases, enable only one FC port in advance of

startup.

If the multipath configuration is left as is, the system may fail to start up normally.

Even if you do not use automatic mounting, we recommend enabling only one FC port in advance of startup

in Rescue mode in order to prevent operational errors.

For details, see the notes on operating system installation in 1.3.2 Notes on system installation.

Page 28: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

7

1.4 ETERNUS Connection Settings For details on the settings required on the ETERNUS when connecting to it, see the ETERNUS manuals at the

following website:

http://www.fujitsu.com/global/services/computing/storage/eternus/documentation/

1.4.1 Settings for Windows

This section describes settings for Windows for a connection to the ETERNUS.

TABLE 1.1 Reservation Conflict responses to Test Unit Ready (for Windows)

Condition

Operating system MSCS or WSFC

used

SafeCLUSTER

used

VERITAS Cluster

Server used Other

Windows Server 2003

SP2,

Windows Server 2003 R2

SP2

Conflict response

Normal

response

(Default)

Windows Server 2008

SP2,

Windows Server 2008

R2, R2 SP1 ,

Windows Server 2012

Normal response

(Default) -

Normal response

(Default)

Normal

response

(Default)

Set the Vendor Unique sense code of the host response for the ETERNUS4000/ETERNUS8000 series by referring to

TABLE 1.2. Vendor Unique sense codes (for Windows). However, the Vendor Unique sense code is suppressed by

default for the ETERNUS DX series and the ETERNUS DX S2 series (current product), so no setting is needed for it.

Page 29: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

8

TABLE 1.2 Vendor Unique sense codes (for Windows)

Server model to be connected

PRIMERGY, PRIMEQUEST 1000 series, or IA server manufactured by another company

GR/ETERNUS multipath driver GR/ETERNUS device driver

ETERNUS disk array

Operating system

Used Not used

Standard multipath driver for Windows Server 2008 (msdsm)

VERITAS Storage Foundation for Windows

Windows Server

2003 SP2,

Windows Server

2003 R2 SP2

- -

ETERNUS 4000

model

400/600

ETERNUS 8000

model

800/1200/2200

Windows Server

2008 SP2,

Windows Server

2008 R2,

Windows Server

2008 R2 SP1

Windows Server

2012

Do not report

(Default)

Do not report

(Default)

Do not report

(Default)

Do not report

(Default)

Windows Server

2003 SP2,

Windows Server

2003 R2 SP2

- -

ETERNUS 4000

model

300/500

ETERNUS 8000

model

700/900/1100/2100

Windows

Server 2008

SP2,

Windows

Server 2008

R2,

Windows

Server 2008 R2

SP1

Windows

Server 2012

Report

(Default)

Report

(Default) Do not report

Report

(Default)

Page 30: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

9

To use the ETERNUS multipath driver or GR multipath driver for a multipath connection, or to use the

ETERNUS device driver or GR device driver for a single-path connection, set the sense code conversion

pattern of the host response to "Do not convert."

If the ETERNUS multipath driver, GR multipath driver, ETERNUS device driver, and GR device driver are not

used, set the sense code conversion pattern of the host response to "Windows (GR/ETERNUS multipath drivers

and device drivers not used) recommended."

TABLE 1.3 Sense code conversion patterns (for Windows)

GR/ETERNUS multipath driver

Operating

system Used Not used

Standard multipath driver

for Windows Server 2008

(msdsm)

VERITAS

Storage

Foundation for

Windows

Windows

Server 2003

SP2,

Windows

Server 2003

R2 SP2

-

Windows

Server 2008

SP2,

Windows

Server 2008

R2,

Windows

Server 2008

R2 SP1

Windows

Server 2012

Do not convert

(Default)

Windows

(GR/ETERNUS

multipath drivers

and device drivers

not used)

recommended

Windows

(GR/ETERNUS

multipath drivers and

device drivers not used)

recommended

Windows

(GR/ETERNUS

multipath drivers

and device

drivers not used)

recommended

For a Windows server that has VMware VCB Proxy installed and operates while sharing LUNs with VMware

ESX, make settings by referring to 1.4.3 Settings for VMware ESX.

Page 31: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

10

TABLE 1.4 Vendor Unique sense code (for Windows)

Setting item Server model to be connected

Vendor Unique sense code

PRIMEQUEST 1000 series Do not report

TABLE 1.5 Sense code conversion pattern (for Windows)

SAN boot environment Server model to be connected

Used Not used

PRIMEQUEST 1000 series Linux (Linux GR multipath driver not

used) recommended

Conforms to setting in each

environment

Note

If this setting does not match the setting in the respective operating system, give priority to this setting.

1.4.2 Settings for Linux

This section describes settings for Linux for a connection to the ETERNUS.

TABLE 1.6 Vendor Unique sense code (for Linux)

Setting item Server model to be connected

Vendor Unique sense code

PRIMEQUEST 1000 series Do not report

TABLE 1.7 Sense code conversion pattern (for Linux)

SAN boot environment Server model to be connected

Used Not used

PRIMEQUEST 1000 series Linux (Linux GR multipath driver not

used) recommended

Conforms to setting in each

environment

Note

- If this setting does not match the setting in the respective operating system, give priority to this setting.

- To use a SAN boot configuration, select "Linux (Linux GR multipath driver not used) recommended" shown

in TABLE 1.7 Sense code conversion pattern (for Linux).

Page 32: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

11

1.4.3 Settings for VMware ESX

Make settings for a connection with the VMware ESX main unit by referring to the following tables:

TABLE 1.8 Inquiry Standard Data Version (for VMware ESX)

TABLE 1.9 Sense code conversion pattern (for VMware ESX)

TABLE 1.10 Host specific mode (for VMware ESX)

TABLE 1.11 Asymmetric/Symmetric Logical Unit Access (for VMware ESX)

The setting values depend on the ETERNUS disk array model used and the ESX version.

TABLE 1.8 Inquiry Standard Data Version (for VMware ESX)

Setting item

Inquiry Standard Data Version

Operating system ETERNUS 4000 model 300/500

ETERNUS 8000 model

700/900/1100/2100

ETERNUS 4000 model 400/600

ETERNUS 8000 model

800/1200/2200

VMware vSphere (ESX4.1,

ESX4.0 / ESXi4.1, ESXi4.0) Version 05 (Default)

VMware vSphere

(ESXi5.1, ESXi5.0) - Version 05 (Default)

TABLE 1.9 Sense code conversion pattern (for VMware ESX)

Setting item

Sense code conversion pattern

Operating system ETERNUS 4000 model 300/500

ETERNUS 8000 model

700/900/1100/2100

ETERNUS 4000 model 400/600

ETERNUS 8000 model

800/1200/2200

VMware vSphere (ESX4.1,

ESX4.0 / ESXi4.1, ESXi4.0) Linux (Linux GR multipath driver not used) recommended

VMware vSphere

(ESXi5.1, ESXi5.0) -

Linux (Linux GR multipath driver

not used)

recommended

Page 33: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

12

TABLE 1.10 Host specific mode (for VMware ESX)

Setting item

Host specific mode

Operating system ETERNUS 4000 model 300/500

ETERNUS 8000 model

700/900/1100/2100

ETERNUS 4000 model 400/600

ETERNUS 8000 model

800/1200/2200

VMware vSphere (ESX4.1,

ESX4.0 / ESXi4.1, ESXi4.0) VMware Mode Normal Mode (Default)

ESX4.1, ESX4.0 / ESXi4.1,

ESXi4.0 - Normal Mode (Default)

TABLE 1.11 Asymmetric/Symmetric Logical Unit Access (for VMware ESX)

Setting item

Asymmetric/Symmetric Logical Unit Access Operating system

ETERNUS 4000 model 300/400/500/600ETERNUS 8000 model

700/800/900/1100/1200/2100/2200

VMware vSphere

(ESX4.1, ESX4.0 /

ESXi4.1, ESXi4.0)

ACTIVE-ACTIVE/PREFERRED_PATH ACTIVE/ACTIVE (Default)

VMware vSphere

(ESXi5.1, ESXi5.0) - ACTIVE/ACTIVE (Default)

For a Windows server that has VMware VCB Proxy installed and operates while sharing LUNs with VMware

ESX, make settings by referring to the following tables:

TABLE 1.12 Inquiry Standard Data Version (for VMware ESX)

TABLE 1.13 Host specific mode (for VMware ESX)

For details on VMware VCB Proxy, see the VMware, Inc. website.

TABLE 1.12 Inquiry Standard Data Version (for VMware ESX)

Setting item Operating system

Inquiry Standard Data Version

Windows Server 2008 SP2 running

as VCB Proxy server Version 05 (Default)

VMware vSphere (ESX 4.1,

ESX 4.0)

Windows Server 2003 SP2 running

as VCB Proxy server Version 04

Page 34: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

13

TABLE 1.13 Host specific mode (for VMware ESX)

Setting item Operating system

Host specific mode

Windows Server 2008 SP2 running

as VCB Proxy server VMware Mode

VMware vSphere (ESX 4.1,

ESX 4.0)

Windows Server 2003 SP2 running

as VCB Proxy server Normal Mode (Default)

For the PRIMEQUEST 1000 series server connected in a SAN boot configuration, make settings by referring to

TABLE 1.15 Sense code conversion pattern (for VMware ESX (PRIMEQUEST 1000 series server

connection)).

TABLE 1.14 Sense code conversion pattern (for VMware ESX)

SAN boot configuration Server model to be connected

Used Not used

PRIMEQUEST 1000 series Linux (Linux GR multipath driver not

used) recommended

Conforms to setting in each

environment

Note

If this setting does not match the setting in the respective operating system, give priority to this setting.

Page 35: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

14

CHAPTER 2 Settings on the Fiber Channel Card

(FC Card) This chapter describes the settings to be made on the FC card in the PRIMEQUEST 1000 series server. With the

resultant settings, the system starts from an LUN of the SAN storage unit in the FC SAN boot environment.

2.1 UEFI Driver Settings on the FC Card

To have the system start from a LUN of the SAN storage unit in the SAN boot environment, the operation

described below is required for all of the HBAs to be used for starting the system.

Executing this operation registers in the HBA the SAN storage unit LUN from which the system is to be started.

This section uses examples of screen displays resulting from the use of UEFI driver versions 4.00a1 and 4.12a7.

All screenshots appearing below are display examples whose contents vary depending on the system

configuration, etc.

Notes

If the UEFI boot menu has the setup menu, select the setup menu and proceed to the work described in

2.2.3 Starting the HBA setup utility.

Different FC card firmware versions cannot be mixed in a single partition. Moreover, different UEFI

driver versions cannot be mixed in a single partition. If you have different versions of the FC card

firmware or UEFI driver, install the same version of the firmware driver, respectively.

According to the UEFI driver version set for the FC card, there is a difference in the following operations:

- Displaying the HBA list

- Starting the HBA setup utility

- Method of making settings for the FC card

Confirm the setting method by referring to the procedures in 2.1.1 Selecting the method of making

settings for the FC card (1) and 2.1.2 Selecting the method of making settings for the FC card (2).

Page 36: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2.1.1 Selecting the method of making settings for the FC card (1)

First, check whether different versions of the UEFI driver have not been set for the FC card.

Note

If there is a mixture of different UEFI driver versions, settings for the FC card cannot be made correctly.

1. Select [Force boot into EFI Boot Manager] from [Boot Selector] in the [Power Control] window of the

MMB. Then, turn on the power. Start the UEFI Shell.

2. From the UEFI Shell, enter the following command to display the driver list.

> drivers

For details on UEFI operation, see the PRIMEQUEST 1000 Series User Interface Operating Instructions

(C122-E109EN) and the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN).

Display in cases without a mixture of different UEFI driver versions for the FC card

The list displays only one [Emulex SCSI Pass Thru Driver] line.

In the following example, [00041214] in the [Emulex SCSI Pass Thru Driver] line indicates the UEFI

driver version.

FIGURE 2.1 Example of driver list output (1)

15

Page 37: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

Remarks

If the list of drivers is not displayed on a single page on the screen, enter "drivers -b".

The list is displayed in units of pages on the screen.

Display in cases with a mixture of different UEFI driver versions for the FC card

The list displays multiple [Emulex SCSI Pass Thru Driver] lines.

In the following example, [00041214] and [00040011] in the [Emulex SCSI Pass Thru Driver] lines

indicate the UEFI driver versions. This means that there are two UEFI driver versions.

In this case, replace UEFI drivers for FC cards to make all the versions the same. Then, try this operation

again.

FIGURE 2.2 Example of driver list output (2)

Remarks

If the list of drivers is not displayed on a single page on the screen, enter "drivers -b".

The list is displayed in units of pages on the screen.

16

Page 38: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2.1.2 Selecting the method of making settings for the FC card (2)

Check the UEFI driver version from the [Device Manager] screen of the Boot Manager Front Page.

1. Select [Force boot into EFI Boot Manager] from [Boot Selector] in the [Power Control] window of the

MMB. Then, turn on the power. Start the UEFI Shell.

2. From the UEFI Shell, enter the following command to display the Boot Manager Front Page.

> exit

3. The Boot Manager Front Page appears. Select [Device Manager], and then press the [Enter] key.

FIGURE 2.3 Boot Manager front page (screen display example)

17

Page 39: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

4. The [Device Manager] screen appears. The setting procedures vary depending on the UEFI driver version.

For the setting procedures, see TABLE 2.1 UEFI driver version display.

TABLE 2.1 UEFI driver version display

UEFI driver version Emulex Configuration Utility shown

on [Device List] screen Item (reference)

4.00a1 or earlier Version not displayed 2.2 Procedure for Setting UEFI Driver

Version 4.00a1 or Earlier on the FC Card

4.12a7 or later Version displayed 2.3 Procedure for Setting UEFI Driver

Version 4.12a7 or Later on the FC Card

[Screen display example]

[Device List] (version not displayed) FIGURE 2.4

18

Page 40: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

FIGURE 2.5 [Device List] (version displayed)

Note

Note the following points when using UEFI driver version 4.12a7 or later to set a SAN boot configuration on

the FC card. (In the above example, Emulex Configuration Utility Ver. is 4.12a7.)

Before deleting a registered boot entry with the Delete Boot Device process, be sure to change the BIOS

enable setting (Set Boot from SAN) to Disable.

Executing the Delete Boot Device process with Enable as the BIOS enable setting (Set Boot from SAN)

may render Emulex Configuration Utility inoperable on rare occasions. In such cases, select [Reset] from

the [Power Control] window of the MMB Web-UI to restart the system. Then, make the settings on the

FC card again.

19

Page 41: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2.2 Procedure for Setting UEFI Driver Version 4.00a1 or Earlier on the FC Card

This section describes the procedure for setting UEFI driver version 4.00a1 or earlier.

2.2.1 Displaying the driver list

1. Select [Force boot into EFI Boot Manager] from [Boot Selector] in the [Power Control] window

of the MMB. Then, turn on the power. Start the UEFI Shell.

2. From the UEFI Shell, enter the following command to display the driver list.

> drivers

FIGURE 2.6 Example of driver list output (3)

Remarks

If the list of drivers is not displayed on a single page on the screen, enter "drivers -b".

The list is displayed in units of pages on the screen.

20

Page 42: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

FIGURE 2.7 Example of driver list output (4)

Remarks

If the list of drivers is not displayed on a single page on the screen, enter "drivers -b".

The list is displayed in units of pages on the screen.

2.2.2 Displaying the HBA list

1. Select [Force boot into EFI Boot Manager] from [Boot Selector] in the [Power Control] window of the

MMB. Then, turn on the power. Start the UEFI Shell.

2. From the UEFI Shell, enter the following command to display an HBA list.

Driver identification numbers are those displayed in the leftmost column in FIGURE D.2 Example of driver

list output.

Specify the driver identification number of the driver whose [DRIVER NAME] is displayed as [Emulex

SCSI Pass Thru Driver].

It is C4 in FIGURE 2.7 Example of driver list output (4).

21

Page 43: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

> drvcfg -s <driver identification number>

FIGURE 2.8 HBA list (1)

22

Page 44: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2.2.3 Starting the HBA setup utility

1. Select the HBA to be used for SAN boot, and then press the [Enter] key.

The menu for HBA setup is displayed.

HBA list (2) FIGURE 2.9

The MMB Web-UI displays the slot containing the mounted HBA as the [PCI-Express Slots] item whose

[Seg/Bus/Dev] values match the Seg#, Bus#, and Dev# values on the screen shown in FIGURE 2.9 HBA list (2).

Remarks

The [IOB] and [PCI_Box] screens of the System menu display the [PCI-Express Slots] items.

Emulex FC EFI-Bios Utility uses hexadecimal notation for the displayed values, and the MMB Web-UI uses

decimal notation.

For details on mounting locations, see APPENDIX B Physical Mounting Locations and Port Numbers in the

PRIMEQUEST 1000 Series Administration Manual (C122-E108EN).

23

Page 45: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

MMB Web-UI display FIGURE 2.10

2.2.4 Displaying the HBA setup utility

From the menu for HBA setup, select [1. Setup Utility], and then press the [Enter] key.

HBA setup FIGURE 2.11

24

Page 46: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2.2.5 Acquiring an HBA WWN

Confirm the WWN of the HBA for which setup is currently being performed.

The WWN of the HBA is displayed as a [Port Name].

HBA setup utility FIGURE 2.12

25

Page 47: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2.2.6 Initializing the HBA setting

Restore the HBA setting to the default state.

Remarks

An HBA that has just been shipped from the factory has initialized settings and does not require the work below.

Perform this work to initialize them again.

1. Select [4. Reset to Default Values] and then press the [Enter] key.

[4. Reset to Default Values] selection screen FIGURE 2.13

26

Page 48: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2. Enter [y].

HBA initialization (1) FIGURE 2.14

3. After the completion of initialization, press any key.

HBA initialization (2) FIGURE 2.15

27

Page 49: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

4. You are returned to the menu.

HBA setup utility FIGURE 2.16

28

Page 50: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2.2.7 Enabling BIOS

Enable the HBA BIOS so that the HBA can recognize the LUNs of the ETERNUS and to enable the system to

be started from one of them.

1. As shown in FIGURE 2.16 HBA setup utility, select [1. Enable or Disable BIOS], and then press the [Enter]

key.

2. When the screen displays the [Disabled] and [Enabled] options, select [Enabled] and then press the [Enter]

key.

Enabling BIOS (1) FIGURE 2.17

29

Page 51: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

3. Confirm that [EFI-Bios Boot Option is Currently ENABLED] is displayed.

Enabling BIOS (2) FIGURE 2.18

4. Press the [Esc] key to return to the screen in FIGURE 2.16 HBA setup utility.

30

Page 52: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2.2.8 Speed and Topology settings

The following describes how to make the Speed and Topology settings.

Static Topology setting

On the [Adapter Configuration Main Menu] screen, make the following setting that corresponds to the

connection pattern (Fabric connection/FCAL connection).

Fabric connection: Point to Point.

FCAL connection: FCAL

Note

Do not set [AUTO Loop First - default.] or [AUTO Point to Point first.]. First, make the above fixed setting.

Otherwise, the connected device will not be normally recognized.

1. Select [2. Configure HBA Parameters], and then press the [Enter] key.

FIGURE 2.19 Static Topology setting (1)

31

Page 53: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2. Select [2. Topology Selection], and then press the [Enter] key.

FIGURE 2.20 Static Topology setting (2)

3. Select the connection method, and then press the [Enter] key.

Fabric connection: Point to Point.

FCAL connection: FCAL

32

Page 54: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

FIGURE 2.21 Selecting [Point to Point.]

FIGURE 2.22 [Point to Point.] displayed

33

Page 55: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

FIGURE 2.23 Selecting [FCAL.]

FIGURE 2.24 [FCAL.] displayed

4. Press the [Esc] key to return to the previous screen.

34

Page 56: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

Static Link Speed setting

With EFI-Bios, make the following setting that corresponds to the connection link speed (2 Gbps/4 Gbps/8

Gbps).

Note

Do not set [Auto negotiate - Default]. First, make the fixed setting for Link Speed. Otherwise, the connected

device will not be normally recognized.

1. After making the static topology setting, press the [Esc] key to return to the screen in FIGURE 2.20 Static

Topology setting (2).

2. Select [4. Force Link Speed], and then press the [Enter] key.

FIGURE 2.25 [4. Force Link Speed] selected on the screen

35

Page 57: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

3. Select the link speed corresponding to the connection environment (connected FC switch or SAN storage

unit), and then press the [Enter] key.

Static Link Speed setting (1) FIGURE 2.26

36

Page 58: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

4. Confirm that the specified link speed is displayed for [Link speed set to x Gb/s].

FIGURE 2.27 Static Link Speed setting (2)

37

Page 59: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

5. Press the [Esc] key to return to the menu.

FIGURE 2.28 Static Link Speed setting (3)

6. Then, press the [Esc] key to return to the next higher menu.

Changing the setting of the opposing device

The setting of the opposing Fibre Channel switch and SAN storage unit disk array must also be made static so

that it corresponds to the static setting of the FC card.

For details on the settings required on the ETERNUS when connecting to it, see the ETERNUS manuals at the

following website:

http://www.fujitsu.com/global/services/computing/storage/eternus/documentation/

38

Page 60: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2.2.9 Boot device setting

1. Select [3. Configure Boot Parameters], and then press the [Enter] key.

Boot device setting (1) FIGURE 2.29

2. The menu for setting boot parameters appears.

Select [4. Configure Boot Devices], and then press the [Enter] key.

Boot device setting (2) FIGURE 2.30

39

Page 61: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

3. A window displays a list of boot entries.

All the entries are empty in the default state as shown in the following figure. Select [01: DID:000000

WWN:00000000 00000000], which is an empty entry. Then press the [Enter] key.

Boot device setting (3) FIGURE 2.31

40

Page 62: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

4. The setting screen for the entry [01: DID:000000 WWN:00000000 00000000] is displayed.

Select [1. Scan Targets], and then press the [Enter] key.

FIGURE 2.32 Boot device setting (4)

Remarks

If the expected LUN is not displayed, there is a possibility that the setting of the SAN storage or the setting or

physical connection of the FC switch is incorrect.

Confirm these settings once again.

41

Page 63: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

5. A list of the targets appears.

Select a target, and then press the [Enter] key.

Boot device setting (5) FIGURE 2.33

6. The LUN connected to the selected target is displayed.

Select the LUN from which the system is to be started. Then press the [Enter] key.

Boot device setting (6) FIGURE 2.34

42

Page 64: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

7. Select the LUN from which the system is to be started. Select [1. Boot this device via WWN.], and then

press the [Enter] key.

Boot device setting (7) FIGURE 2.35

43

Page 65: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

8. Confirm that the list of boot entries displays the LUN registered in entry [01].

FIGURE 2.36 Boot device setting (8)

9. Press the [Esc] key to return to the higher menu.

FIGURE 2.37 Boot device setting (9)

44

Page 66: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

10. Then, press the [Esc] key to return to the next higher menu.

Boot device setting (10) FIGURE 2.38

11. Then, press the [Esc] key to return to the next higher menu.

Boot device setting (11) FIGURE 2.39

45

Page 67: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

12. Then, press the [Esc] key to return to the next higher menu.

Boot device setting (12) FIGURE 2.40

13. For a multipath configuration, make the settings described in the sections from 2.2.3 Starting the HBA setup

utility to 2.2.8 Speed and Topology settings for all the HBAs connected to the SAN storage unit LUN from

which the system is started. Also, after installing the operating system and multipath driver, perform the

operation described in 2.2.9 Boot device setting for all the HBAs used to start the system.

When all the settings are completed, press the [Esc] key to return to the UEFI Shell.

46

Page 68: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2.2.10 Applying settings

Restart the system to apply the changes in the settings

Execute the reset command with the UEFI Shell, or select [Reset] from the [Power Control] window of the

MMB Web-UI to restart the system.

FIGURE 2.41 Restarting the system

2.2.11 Recording the WWN of the FC port

According to the design drawing of the SAN boot environment, write down the WWN (World Wide Name),

specific address information assigned to the FC port of the FC card of each server.

To check the WWN, select [1. Setup Utility] from the menu displayed with Emulex FC EFI-Bios Utility, and

then check [Port Name] on the displayed screen.

Remarks

If you are updating FC card firmware (e.g., Boot BIOS), check the WWN after the firmware update.

47

Page 69: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

48

To clearly identify the mounting location of the FC card, record the host name (the one that identifies the

PRIMEQUEST 1000 series server), mounted card, mounting slot location, BUS number, and DEV number.

For the BUS number and slot number, check the BUS number and slot number of the target HBA from the

[IOB] menu and [PCI_Box] menu of the MMB Web-UI.

The BUS number appears as the middle number of the three numbers delimited by "/" in the [Seg/Bus/Dev]

item.

The following example shows how the WWNs are recorded.

TABLE 2.2 WWN recording example

PCI FC port Host name (to identify a

server)

Mounted card (type)

BUS-DEV I/O

address WWN

0x - 00 x000 10 00 00 00 C9 ** Server #1 MC-0JFC21

0x - 00 x000 10 00 00 00 C9 **

0x - 00 x000 10 00 00 00 C9 ** Server #2 MC-0JFC21

0x - 00 x000 10 00 00 00 C9 **

: : : : :

: : : : :

Notes

Always keep the WWN information up to date, and share and manage it together with the SAN boot

system administrator and maintenance personnel.

If the WWN information is wrong, connection to the SAN storage is disabled and problems such as being

unable to start the operating system occur.

When an FC card is moved or hardware is replaced for maintenance purposes, the WWN may be

changed.

Page 70: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2.3 Procedure for Setting UEFI Driver Version 4.12a7 or Later on the FC Card

This section describes the procedure for setting UEFI driver version 4.12a7 or later.

2.3.1 Displaying the Device Manager

1. From the UEFI Shell, enter the following command to display the Boot Manager Front Page.

> exit

2. Select [Device Manager], and then press the [Enter] key.

FIGURE 2.42 Boot Manager front page (screen display example)

3. The [Device Manager] screen appears.

49

Page 71: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2.3.2 Starting the HBA setup utility

1. Select [Emulex Configuration Utility Ver: x.xxxx] from the [Device Manager] screen, and then press the

[Enter] key

FIGURE 2.43 Device Manager screen

50

Page 72: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2. Select [Emulex Configuration Setup Utility] from the [Emulex Configuration Utility] screen, and then press

the [Enter] key.

FIGURE 2.44 Emulex Configuration Utility screen

3. An HBA list appears for selecting the setup target.

51

Page 73: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2.3.3 Acquiring an HBA WWN

Confirm the WWN of the HBA for which setup is currently being performed.

The WWN of the HBA is displayed as [Port Name].

FIGURE 2.45 HBA list (Port Name displayed)

52

Page 74: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2.3.4 Selecting an HBA

1. From the [Adapter Selection] screen, select the HBA to be used for SAN boot, and then press the [Enter]

key.

FIGURE 2.46 [Adapter Selection] screen (HBA list)

2. The [Emulex Adapter Configuration Main Menu] screen appears.

FIGURE 2.47 [Emulex Adapter Configuration Main Menu] screen

53

Page 75: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

The MMB Web-UI displays the slot containing the mounted HBA as the [PCI-Express Slots] item whose

[Seg/Bus/Dev] values match the Seg#, Bus#, and Dev# values on the screen shown in FIGURE 2.46 [Adapter

Selection] screen (HBA list).

Remarks

The [IOB] and [PCI_Box] screens of the System menu display the [PCI-Express Slots] items.

The [Emulex FC EFI-Bios Utility] screen uses hexadecimal notation for the displayed values, and the MMB

Web-UI uses decimal notation.

For details on mounting locations, see APPENDIX B Physical Mounting Locations and Port Numbers in the

PRIMEQUEST 1000 Series Administration Manual (C122-E108EN).

FIGURE 2.48 MMB Web-UI display

54

Page 76: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2.3.5 Initializing the HBA setting

Restore the HBA setting to the default state.

Remarks

An HBA that has just been shipped from the factory has initialized settings and does not require the work below.

Perform this work to initialize them again.

1. Select [Set Emulex Adapter to Default Settings], and then press the [Enter] key.

FIGURE 2.49 Menu for HBA setup

55

Page 77: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2. The [Set Emulex Adapter to Default Settings] screen appears. Select [Set Adapter Defaults], and then press

the [Enter] key.

FIGURE 2.50 [Set Emulex Adapter to Default Settings] screen

3. After the completion of initialization, you are returned to the [Adapter Selection] screen.

FIGURE 2.51 [Adapter Selection] screen (HBA list)

56

Page 78: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2.3.6 Enabling BIOS

Enable the HBA BIOS so that the HBA can recognize the LUNs of the ETERNUS and to enable the system to

be started from one of them.

1. Select [Set Boot from SAN <Disable>] from the [Emulex Adapter Configuration Main Menu] screen.

The screen for selecting <Disable> or <Enable> appears. Select <Enable>, and then press the [Enter] key.

FIGURE 2.52 [Set Boot from SAN] (Enabling boot (1))

57

Page 79: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2. Confirm that [Set Boot from SAN < Enable >] is displayed.

FIGURE 2.53 [Set Boot from SAN] (Enabling boot (2))

58

Page 80: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2.3.7 Speed and Topology settings

The following describes how to make the Speed and Topology settings.

Note

Do not set [AUTO Loop First - default.] or [AUTO Point to Point first.]. First, make the fixed setting.

Otherwise, the connected device will not be normally recognized.

Static Topology setting

On the [Emulex Adapter Configuration Main Menu] screen, make the following setting that corresponds to the

connection pattern (Fabric connection/FCAL connection).

1. Select [Configure HBA and Boot Parameters], and then press the [Enter] key.

FIGURE 2.54 Static Topology setting (1)

59

Page 81: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2. Select [Topology Selection <AUTO Loop First –default>], and then press the [Enter] key.

FIGURE 2.55 Static Topology setting (2)

60

Page 82: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

3. Select the connection method, and then press the [Enter] key. Change the setting from the default setting of

[AUTO Loop First -default] as follows.

Fabric connection: Point to Point.

FCAL connection: FCAL

FIGURE 2.56 Selecting [Point to Point.]

61

Page 83: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

FIGURE 2.57 [Point to Point.] displayed

FIGURE 2.58 Selecting [FCAL.]

62

Page 84: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

FIGURE 2.59 [FCAL.] displayed

63

Page 85: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

Static Link Speed setting

With EFI-Bios, make the following setting that corresponds to the connection link speed (2 Gbps/4 Gbps/8

Gbps).

Note

Do not set [Auto negotiate - Default]. First, make the fixed setting for Link Speed. Otherwise, the connected

device will not be normally recognized.

1. Select [Force Link Speed <Auto negotiate - Default>], and then press the [Enter] key.

FIGURE 2.60 Static Link Speed setting (1)

64

Page 86: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2. Select the link speed corresponding to the connection environment (connected FC switch or SAN storage

unit), and then press the [Enter] key.

FIGURE 2.61 Static Link Speed setting (2)

3. Confirm that the specified link speed is displayed for [Force Link speed <xxxxxxx>].

FIGURE 2.62 Static Link Speed setting (3)

65

Page 87: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

4. Select [Commit Changes], and then press the [Enter] key.

FIGURE 2.63 Topology / Link Speed change confirmation (1)

66

Page 88: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

5. After the completion of the Commit Changes process, you are returned to the [Emulex Adapter

Configuration Main Menu] screen.

FIGURE 2.64 Topology / Link Speed change confirmation (2)

Remarks

After changing the [Topology Selection] or [Force Link Speed] settings and then selecting [Discard Changes],

if you are returned to the screen for changing settings, the changes to the FC card settings have been discarded.

However, you may still see the changed settings displayed by the utility.

If so, select the FC card again from the menu as described in 2.3.4 Selecting an HBA, before proceeding with

the work.

Changing the setting of the opposing device

The setting of the opposing Fibre Channel switch and SAN storage unit disk array must also be made static so

that it corresponds to the static setting of the FC card.

For details on the settings required on the ETERNUS when connecting to it, see the ETERNUS manuals at the

following website:

http://www.fujitsu.com/global/services/computing/storage/eternus/documentation/

67

Page 89: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2.3.8 Boot device setting

1. Select [Scan for Fibre Device] from the [Emulex Adapter Configuration Main Menu] screen, and then press

the [Enter] key.

FIGURE 2.65 Boot device setting (1)

68

Page 90: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2. [Please Wait] is displayed during the search process.

FIGURE 2.66 Boot device setting (2)

3. Fibre Device information appears when the search process has been successful.

FIGURE 2.67 Boot device setting (3)

69

Page 91: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

Remarks

If the expected Fibre Device is not displayed, there is a possibility that the setting of the SAN storage or the

setting or physical connection of the FC switch is incorrect.

Confirm these settings once again.

4. Select [Go to Configuration Main Menu], and then press the [Enter] key.

FIGURE 2.68 Boot device setting (4)

70

Page 92: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

5. The [Emulex Adapter Configuration Main Menu] screen appears. Select [Add Boot Device], and then press

the [Enter] key.

FIGURE 2.69 Boot device setting (5)

71

Page 93: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

6. The [SAN Discovery Target List] screen displays the targets found in the search by [Scan for Fibre Device].

Select the Fibre Device specifying the boot device, and then press the [Enter] key.

FIGURE 2.70 Boot device setting (6)

72

Page 94: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

7. The LUN connected to the selected target is displayed. Select the LUN from which the system is to be

started. Then, press the [Enter] key. A confirmation screen appears.

FIGURE 2.71 Boot device setting (7)

8. Select [Commit Changes], and then press the [Enter] key.

FIGURE 2.72 Boot device setting (8)

73

Page 95: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

9. Select [Return to Previous Page], and then press the [Enter] key to return to the higher menu.

FIGURE 2.73 Boot device setting (9)

10. Select [Go to Configuration Main Menu], and then press the [Enter] key to return to the higher menu.

FIGURE 2.74 Boot device setting (10)

74

Page 96: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

11. Select [Delete Boot Device] from the [Emulex Adapter Configuration Main Menu] screen, and then press

the [Enter] key. (Here, confirm only the registration status of the boot device that was set with [Commit

Changes].)

FIGURE 2.75 Boot device setting (11)

75

Page 97: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

12. Confirm the registration of the boot device that was set with [Commit Changes].

In the following example, LUN 0007 is confirmed connected with the target WWN: 207100B 5D6A0510.

FIGURE 2.76 Boot device setting (12)

13. Select [Discard Changes], and then press the [Enter] key to return to the higher menu.

FIGURE 2.77 Boot device setting (13)

76

Page 98: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

14. Select [Back to Display Adapters and RECONNECT DEVICES], and then press the [Enter] key to return to

the higher menu.

FIGURE 2.78 Boot device setting (14)

77

Page 99: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

15. For a multipath configuration, make the settings described in the sections from 2.3.2 Starting the HBA setup

utility to 2.2.7 Speed and Topology settings for all the HBAs connected to the SAN storage unit LUN from

which the system is started. Also, after installing the operating system and multipath driver, perform the

operation described in 2.2.8 Boot device setting for all the HBAs used to start the system.

After finishing all the settings, select [Exit Emulex HBA Configuration Utility], and then press the [Enter]

key to return to the Device Manager menu.

FIGURE 2.79 Boot device setting (15)

Note

If "Save changes? (Y/N)" appears following the operations below, press the [N] key. You need not perform

another operation here because the [Commit Changes] or [Discard Changes] operation from the menu

completes the task of changing or discarding settings.

Select the relevant item from the [Delete Boot Device] or [Change Boot Device Order] menu.

Select [Commit Changes] or [Discard Changes].

Go back to the [Delete Boot Device] or [Change Boot Device Order] menu.

78

Page 100: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

FIGURE 2.80 [Save changes?] dialog box

Remarks

If the [Delete Boot Device] or [Change Boot Device Order] menu is used only for a status check (no setting

change operation), "Save changes? (Y/N)" does not appear.

79

Page 101: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2.3.9 Applying settings

Restart the system to apply the changes in the settings.

To restart the system, use the following procedure, or select [Reset] from the [Power Control] window of the

MMB Web-UI.

1. Press the [Esc] key to go to the Boot Manager Front Page.

FIGURE 2.81 Restarting the system (1)

80

Page 102: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2. Select [Boot Maintenance Manager], and then press the [Enter] key to go to the [Boot Maintenance

Manager] screen.

FIGURE 2.82 Restarting the system (2)

3. Select [Reset System], and then press the [Enter] key. The system is restarted.

FIGURE 2.83 Restarting the system (3)

81

Page 103: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2.3.10 Recording the WWN of the FC port

According to the design drawing of the SAN boot environment, write down the WWN (World Wide Name),

specific address information assigned to the FC port of the FC card of each server.

Confirm the WWN with [Port Name] in the [Adapter Selection] menu. The menu appears after the [Emulex

Configuration Utility] restart.

FIGURE 2.84 [Adapter Selection] menu

Remarks

If you are updating FC card firmware (e.g., Boot BIOS), check the WWN after the firmware update.

To clearly identify the mounting location of the FC card, record the host name (the one that identifies the

PRIMEQUEST 1000 series server), mounted card, mounting slot location, BUS number, and DEV number.

For the BUS number and slot number, check the BUS number and slot number of the target HBA from the

[IOB] menu and [PCI_Box] menu of the MMB Web-UI.

The BUS number appears as the middle number of the three numbers delimited by slash in the [Seg/Bus/Dev]

item.

The following example shows how the WWNs are recorded.

82

Page 104: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

83

TABLE 2.3 WWN recording example

PCI FC port Host name (to identify a

server)

Mounted card (type)

BUS-DEV WWN

0x - 00 10 00 00 00 C9 ** Server #1 MC-0JFC21

0x - 00 10 00 00 00 C9 **

0x - 00 10 00 00 00 C9 ** Server #2 MC-0JFC21

0x - 00 10 00 00 00 C9 **

: : : :

: : : :

Notes

- Always keep the WWN information up to date, and share and manage it together with the SAN boot system

administrator and maintenance personnel.

- If the WWN information is wrong, connection to the SAN storage is disabled and problems such as being

unable to start the operating system occur.

- When an FC card is moved or hardware is replaced for maintenance purposes, the WWN may be changed.

Page 105: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

84

CHAPTER 3 Installing Windows This section describes how to install Windows in the FC SAN boot environment.

This section describes the procedure for installing Windows on the PRIMEQUEST 1000 series server. After

carrying out the installation procedure in 3.1 Installing Windows Server 2008/2012 or 3.2 Installing Windows

Server 2003 SP2, carry out the procedures in 3.3 Changing and Checking the Setting of Detailed FC Card

Information to 3.5 Completing Installation.

3.1 Installing Windows Server 2008/2012 This section describes how to install the Windows Server 2008 SP2.

The same installation procedure also applies to Windows Server 2008 R2/Windows Server 2012

All screenshots appearing below are display examples whose contents vary depending on the system

configuration, etc.

3.1.1 Preparing for Windows Server 2008/2012 installation

Make settings for installation in advance.

For details on this advance setup, see 4.4.1 Advance setup in the PRIMEQUEST 1000 Series Installation

Manual (C122-E107EN).

For a multipath configuration, disconnect the secondary cable connected to the server.

Specifically, use a single path configuration (connection with only one FC cable) until you complete the

installation of the operating system and multipath driver.

If the server is in a multipath connection state, the operating system cannot be installed correctly. Manually

disconnect the secondary FC path beforehand (more specifically, disconnect the secondary cable of each

server).

Remarks

Disconnect all HDDs, including the built-in HDD, other than the HDD with the installation destination LUN.

You can confirm that all of them are disconnected, by starting the Boot Manager Front Page and selecting [Boot

Maintenance Manager] - [Boot Options] - [Change Legacy HDD Boot Priority].

For details on how to check the connected HDDs, see "How to check the connected HDDs."

Page 106: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

-How to check the connected HDDs

1. After powering on the partition, press any key ([Space] key, for example) other than the [Enter] key while

the FUJITSU logo is displayed, to display the Boot Manager Front Page.

FIGURE 3.1 Logo at startup

2. The Boot Manager Front Page appears. Select [Boot Maintenance Manager], and press the [Enter] key.

[BIOS] screen FIGURE 3.2

85

Page 107: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

3. The [Boot Maintenance Manager] screen appears. Select [Boot Options]. Press the [Enter] key.

[Boot Maintenance Manager] screen FIGURE 3.3

4. The [Boot Options] screen appears. Select [Change Legacy HDD Boot Priority], which is the sixth option

from the top. Press the [Enter] key.

[Boot Options] screen FIGURE 3.4

86

Page 108: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

5. The [Change Legacy HDD Boot Priority] screen appears. Confirm that all the devices displayed here are for

only one FC. FIGURE 3.5 [Change Legacy HDD Boot Priority] screen (example) shows PCI bus number

0x0D, device number 0, function number 0, WWN 220000E000A80481, and LUN 0x002B.

[Change Legacy Boot Order] screen (example) FIGURE 3.5

87

Page 109: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

3.1.2 Installing the OS and bundled software

Use SVIM to install the OS and bundled software.

1. Make the setting for booting the partition from a remote storage device.

Remarks

If the operating system supports UEFI mode, you can install it in UEFI mode by using the following

procedure to change the boot order.

1. After powering on the partition, press any key ([Space] key, for example) other than the [Enter] key

while the FUJITSU logo is displayed, to display the Boot Manager Front Page.

2. Select the following items from the menu in the following order, on the Boot Manager Front Page:

[Boot Maintenance Manager] - [Boot Options] - [Change Boot Order] - [Change the order]

3. Specify [UEFI:DVD/CD 0] as the highest-priority device to boot from remote storage.

[Change Boot Order] menu FIGURE 3.6

The following table describes the meaning of the menu.

88

Page 110: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

89

TABLE 3.1 [Change Boot Order] menu

Menu item Description

UEFI: Embedded DVD/CD Specify this item when using the built-in DVD drive for installation in

UEFI mode.

Legacy Boot Specify this item for BIOS mode. Also specify [Legacy Boot] when

using the built-in DVD drive for installation in BIOS mode.

UEFI Shell Do not use this item.

4. Specify [Commit Changes and Exit] - [Reset System] to reboot the partition.

2. Insert ServerView Suite DVD1 into the DVD drive. Then, power on the partition.

3. After a moment, the language selection window appears. Select [English] for installation in English.

4. In the initially displayed window, click the [Next] button.

5. Select [Deployment] in the [Welcome to ServerView Installation Manager] window.

6. Select an installation mode and the operating system to be installed. Then, set up the operating system.

7. Click [Install].

Installation begins.

Replace the media with the operating system installation media according to the SVIM instructions.

3.1.3 Various post-installation settings

Make various settings by referring to CHAPTER 5 Work after Operating System Installation (PRIMEQUEST

1800E2) or CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) in the

PRIMEQUEST 1000 Series Installation Manual (C122-E107EN).

Page 111: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

90

3.1.4 Advanced settings of driver parameters

Use the utility (HBAnyware) to make advanced settings of driver parameters.

Remarks

Depending on the driver version, read "HBAnyware" as "OneCommand Manager."

Install HBAnyware if the HBAnyware has not been installed.

The installation of HBAnyware can be confirmed by the existence of [Emulex] - [HBAnyware], which is

displayed by selecting [Programs] from the [Start] menu.

1. Download the driver and utility of the Fibre Channel card from the following URL:

http://jp.fujitsu.com/platform/server/primequest/download-e/

Note

The downloaded binary file has a description about the PRIMERGY, but the driver and utility can

be used for the PRIMEQUEST 1000 series.

2. Execute the downloaded file by double-clicking it.

3. The prompt screen for the cmd.exe (a window with a black background) is displayed for a while,

and then the file is extracted.

4. After the extraction is completed, the window is automatically closed.

The downloaded file is extracted and folders or files are newly created.

Remarks

If the window is not closed in spite of the display of "Installation Completed" in the window, click

the [Finish] button to close the window.

Page 112: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

91

5. Double-click storportminiportkit_XXXXX.exe in the extracted FC_vXXXXXX directory to run it.

Remarks

"XXXXX" represents the version and must be replaced with a suitable character string.

For details on advanced settings of driver parameters, see the manual of HBAnyware

This completes the installation procedure for a single path configuration. Proceed to 3.3 Changing and

Checking the Setting of Detailed FC Card Information. To use the built-in HDD, shut down the system

and then add the HDD.

For a multipath configuration, proceed to step 6 in 3.1.5 For a multipath configuration.

3.1.5 For a multipath configuration

1. Install the ETERNUS multipath driver.

Insert the CD-ROM disk of the ETERNUS multipath driver, and then run Setup.msi in the Japanese\Server

folder. Follow the instructions on the screen to perform the installation.

Remarks

At this time, leave the secondary FC path cable disconnected.

2. Restore the multipath connection.

After the installation of the ETERNUS multipath driver, a message prompting you to restart the system is

displayed. Select [No], and manually shut down the operating system.

After once powering off the partition, reconnect the cable of the FC path that was disconnected in step 1 and

then start the operating system.

Then, proceed to 3.3 Changing and Checking the Setting of Detailed FC Card Information.

Page 113: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

92

3.2 Installing Windows Server 2003 SP2 This section describes how to install the Windows Server 2008 SP2.

The same installation procedure also applies to Windows Server 2008 R2 SP2.

All screenshots appearing below are display examples whose contents vary depending on the system

configuration, etc.

3.2.1 Preparing to install Windows Server 2003 SP2

Before the installation, create an ISO image of the I/O controller. To create an ISO image, use ServerView Suite

DVD1 that comes with the PRIMEQUEST 1000 series server or the relevant module downloaded from the

PRIMEQUEST website.

For a multipath configuration, disconnect the secondary cable connected to the server.

Specifically, use a single path configuration (connection with only one FC cable) until you complete the

installation of the operating system and multipath driver.

If the server is in a multipath connection state, the operating system cannot be installed correctly. Manually

disconnect the secondary FC path beforehand.

Remarks

Disconnect all HDDs, including the built-in HDD, other than the HDD with the installation destination LUN.

You can confirm that all of them are disconnected, by starting the Boot Manager Front Page and selecting [Boot

Maintenance Manager] - [Boot Options] - [Change Legacy HDD Boot Priority].

For details on how to check the connected HDDs, see "How to check the connected HDDs."

3.2.2 Preparing for the FC card driver

1. In the Windows environment (Windows2000/XP/2000 Server/2003 Server, etc.), run

***StorportMiniportKit_***.exe stored in ServerView Suite DVD1.

Otherwise, download *** StorportMiniportKit_***.exe from the PRIMEQUEST website, and then run it.

2. When the [Storport Miniport Driver Kit] window appears, click the [Next] button.

3. Enter a destination folder to extract files (C:\Program Files\Emulex is set by default). Then, click the

[Install] button.

Files are extracted.

4. Uncheck the [Start AutoPilot Installer] check box. Then, click the [Finish] button.

Page 114: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

93

5. Copy to a formatted floppy disk the files in either of the following relevant folders, based on the

environment of the operating system to be installed.

for x86: C:\Program Files\Emulex\AutoPilot Installer\Drivers\Storport\x86

for x64: C:\Program Files\Emulex\AutoPilot Installer\Drivers\Storport\x64

Notes

The paths above assume that the extraction destination is the default folder of C:\Program Files\Emulex.

If the extraction destination is changed, replace this part with the changed path. The above created FD is

the FC card driver FD.

For a new installation of Windows Server 2003 SP2, you need to create the driver FD with v1.30a6 or

v1.30a9 of the FC card driver. The driver FD is required for operating system installation using FC card

driver v2.01a4 or later. After completing the operating system installation, use v2.01a4 or a later version

of the installation module to update the driver.

3.2.3 Installing the OS and bundled software

Use SVIM from the remote storage or the built-in DVD drive to install the OS and bundled software.

Use the following procedure.

1. Make the setting for booting the partition from the built-in DVD drive.

Remarks

To install Windows Server 2003 SP2 from the built-in DVD drive, be sure to set "Legacy Boot" as

described in TABLE 3.2 [Change Boot Order] menu. "UEFI : Embedded DVD/CD" is unsupported.

1. After powering on the partition, press any key ([Space] key, for example) other than the [Enter] key

while the FUJITSU logo is displayed, to display the Boot Manager Front Page.

2. Select the following items from the menu in the following order, on the Boot Manager Front Page:

[Boot Maintenance Manager] - [Boot Options] - [Change Boot Order] - [Change the order]

3. Specify [UEFI:DVD/CD 0] as the highest-priority device to boot from remote storage.

Page 115: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

[Change Boot Order] menu FIGURE 3.7

The following table describes the meaning of the menu.

TABLE 3.2 [Change Boot Order] menu

Menu item Description

UEFI: Embedded DVD/CD Specify this item when using the built-in DVD drive for installation in

UEFI mode.

Legacy Boot Specify this item for BIOS mode. Also specify [Legacy Boot] when

using the built-in DVD drive for installation in BIOS mode.

UEFI Shell Do not use this item.

4. Specify [Commit Changes and Exit] - [Reset System] to reboot the partition.

2. Insert ServerView Suite DVD1 into the DVD drive. Then, power on the partition.

3. After a moment, the language selection window appears. Select [English] for installation in English.

4. In the initially displayed window, click the [Next] button.

5. Select [Deployment] in the [Welcome to ServerView Installation Manager] window.

6. Select an installation mode and the operating system to be installed. Then, set up the operating system.

94

Page 116: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

95

7. Click [Install].

Installation begins.

Replace the media with the operating system installation media according to the SVIM instructions.

8. Install the FC card driver.

When the following message is displayed, press the [S] key.

To specify additional SCSI adapters, CD-ROM drives, or special disk controllers for use with

Windows, including those for which you have a device support disk from a mass storage device

manufacturer, press S.

When the following message is displayed, insert the previously created FC card driver FD into the remote

storage of the partition, and then press the [Enter] key.

Please insert the disk labeled Manufacturer-supplied hardware support disk into Drive A:

Then, the following message is displayed.

You have chosen to configure a SCSI Adapter for use with Windows, using a device support disk

provided by an adapter manufacturer. Select the SCSI Adapter you want from the following list, or

press ESC to return to the previous screen.

9. Select the following FC card.

Select [Emulex LPe11002] since the MC-0JFC21 card is the Emulex Lpe11002 PCIe-Fibre Channel

HBA.

10. Follow the instructions on the screen to perform the installation.

When a message telling you to insert the driver FD is displayed during the installation, insert the

previously created driver FD into the remote storage, and then press the [Enter] key.

11. Follow the instructions from the setup program to continue the installation work.

Note

A warning message about a restart by the setup program appears during the installation process. At that time,

wait for the automatic restart.

Page 117: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

96

For a SAN boot configuration, apply the following hot fix related to the Storport driver:

KB940467

Detailed information about this hot fix is available at the following Microsoft webpage:

http://support.microsoft.com/kb/940467/

If you have a SupportDesk Service agreement, contact SupportDesk for inquiries. Otherwise, acquire

information from Microsoft.

Note

For a SAN boot configuration, be sure to apply the above hot fix.

3.2.4 Installing HBAnyware

Confirm the utility (HBAnyware).

Remarks

Depending on the driver version, read "HBAnyware" as "OneCommand Manager."

Install HBAnyware if the following applies:

The FC card is installed,

and

HBAnyware has not been installed.

The installation of HBAnyware can be confirmed by the existence of [Emulex] - [HBAnyware], which is

displayed by selecting [All Programs] from the [Start] menu.

1. Download the driver and utility of the Fibre Channel card from the following URL:

http://primeserver.fujitsu.com/primequest/download-e/

Note

The downloaded binary file has a description about the PRIMERGY, but the driver and utility can be used

for the PRIMEQUEST 1000 series.

Page 118: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

97

2. Execute the downloaded file by double-clicking it.

The prompt screen for the cmd.exe (a window with the black background) is displayed for a while, and then

the file is extracted.

3. After the extraction is completed, the window is automatically closed.

The downloaded file is extracted and folders or files are newly created.

Remarks

If the window is not closed in spite of the display of "Installation Completed" in the window, click the

[Finish] button to close the window.

4. Double-click storportminiportkit_XXXXX.exe in the extracted FC_vXXXXXX directory to run it.

Remarks

"XXXXX" represents the version and must be replaced with a suitable character string.

5. This completes the installation procedure for a single path configuration. Proceed to 3.3 Changing and

Checking the Setting of Detailed FC Card Information. To use the built-in HDD, shut down the system and

then add the HDD.

For a multipath configuration, proceed to step 6 in 3.2.7 For a multipath configuration.

3.2.5 Making various settings after installation

Make various settings by referring to CHAPTER 5 Work after Operating System Installation (PRIMEQUEST

1800E2) or CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) in the

PRIMEQUEST 1000 Series Installation Manual (C122-E107EN).

Page 119: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

98

3.2.6 Advanced settings of driver parameters

Use the utility (HBAnyware) to make advanced settings of driver parameters.

Remarks

Depending on the driver version, read "HBAnyware" as "OneCommand Manager."

Install HBAnyware if the HBAnyware has not been installed.

The installation of HBAnyware can be confirmed by the existence of [Emulex] - [HBAnyware], which is

displayed by selecting [Programs] from the [Start] menu.

1. Download the driver and utility of the Fibre Channel card from the following URL:

http://jp.fujitsu.com/platform/server/primequest/download-e/

Note

The downloaded binary file has a description about the PRIMERGY, but the driver and utility can be used

for the PRIMEQUEST 1000 series.

2. Execute the downloaded file by double-clicking it.

3. The prompt screen for the cmd.exe (a window with a black background) is displayed for a while, and then

the file is extracted.

4. After the extraction is completed, the window is automatically closed.

The downloaded file is extracted and folders or files are newly created.

Remarks

If the window is not closed in spite of the display of "Installation Completed" in the window, click the

[Finish] button to close the window.

5. Double-click storportminiportkit_XXXXX.exe in the extracted FC_vXXXXXX directory to run it.

Remarks

"XXXXX" represents the version and must be replaced with a suitable character string.

For details on advanced settings of driver parameters, see the manual of HBAnyware.

Page 120: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

99

This completes the installation procedure for a single path configuration. Proceed to 3.3 Changing and

Checking the Setting of Detailed FC Card Information. To use the built-in HDD, shut down the system and

then add the HDD.

For a multipath configuration, proceed to step 3.2.7 For a multipath configuration.

3.2.7 For a multipath configuration

1. Install the ETERNUS multipath driver.

Insert the CD-ROM disk of the ETERNUS multipath driver, and then run Setup.msi in the

Japanese\Server folder. Follow the instructions on the screen to perform the installation.

Remarks

At this time, leave the secondary FC path cable disconnected.

2. Restore the multipath connection.

After the installation of the ETERNUS multipath driver, a message prompting you to restart the

system is displayed. Select [No], and manually shut down the operating system.

After once powering off the partition, connect the cable and then start the operating system. This

completes the work. To use the built-in HDD, confirm startup with a multipath before shutting

down the system, and then add the HDD.

Then, proceed to 3.3 Changing and Checking the Setting of Detailed FC Card Information.

Page 121: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

100

3.3 Changing and Checking the Setting of Detailed FC Card Information

To increase the stability of connectivity with the ETERNUS series machine, adjust some of the driver

parameters after installing the operating system and driver.

To increase the stability of connectivity with the ETERNUS series machine, adjust some of the driver

parameters after installing the operating system and driver.

3.3.1 Setting driver parameters (for HBAnyware)

1. Click the [Start] button to select [Programs] or [All programs], and then select [Emulex] - [HBAnyware].

HBAnyware starts.

The local server and the HBAs under its control are displayed in the left side of the window. Select the local

server and then click the [Driver Parameters] tab in the right side of the window.

Note

Driver parameters can be set not for the local server but for each HBA. If driver parameters are set for each

HBA, the HBA may be changed due to replacement for maintenance purposes or server switching. In such a

case, the driver parameters are set to the default setting values. As a rule, select the local server and then set the

driver parameters.

2. Set the following driver parameters.

Topology

Queue Depth

Queue Target

Link Speed

For details on the settings required on the ETERNUS when connecting to it, see the ETERNUS manuals at the

following website:

http://www.fujitsu.com/global/services/computing/storage/eternus/documentation/

Page 122: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

101

3. Confirm the settings made so far.

After finishing all the settings, from the [File] menu, select [Exit] to quit HBAnyware.

Then, proceed to 3.4 Checking Registry Information.

3.4 Checking Registry Information Check the set registry value for the PRIMEQUEST 1000 series server (registry value name: TimeOutValue).

If the registry does not have it (registry value name: TimeOutValue) create it. For details, see the user's guide

for the FC card.

Page 123: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

102

3.4.1 Checking the TimeOutValue setting value

For details on the settings required on the ETERNUS when connecting to it, see the ETERNUS manuals at the

following website:

http://www.fujitsu.com/global/services/computing/storage/eternus/documentation/l.

After completion of the registry setting check, proceed to 3.5 Completing Installation.

3.5 Completing the Windows Installation

After completing the Windows installation and settings, restart the system to enable the settings.

Page 124: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

103

CHAPTER 4 Installing RHEL This chapter describes how to install RHEL on the PRIMEQUEST 1000 series server.

4.1 Installing RHEL

This section describes how to install RHEL.

All screenshots appearing below are display examples whose contents vary depending on the system

configuration, etc.

4.1.1 Preparing for RHEL installation

Make settings for installation in advance.

For details on this advance setup, see 4.4.1 Advance setup in the PRIMEQUEST 1000 Series Installation

Manual (C122-E107EN).

For a multipath configuration, disconnect the secondary cable connected to the server.

Specifically, use a single path configuration (connection with only one FC cable) until you complete the

installation of the operating system and multipath driver.

If the server is in a multipath connection state, the operating system cannot be installed correctly. Manually

disconnect the secondary FC path beforehand.

Remarks

Disconnect all HDDs, including the built-in HDD, other than the HDD with the installation destination LUN.

You can confirm that all of them are disconnected, by starting the Boot Manager Front Page and selecting [Boot

Maintenance Manager] - [Boot Options] - [Change Legacy HDD Boot Priority].

For details on how to check the connected HDDs, see "How to check the connected HDDs" in 3.1.1 Preparing

for Windows Server 2008/2012 installation.

4.1.2 Installing the OS and bundled software

Use SVIM to install the OS and bundled software.

1. Make the setting for booting the partition from a remote storage device.

Remarks

If the operating system supports UEFI mode, you can install it in UEFI mode by using the following

procedure to change the boot order.

Page 125: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

1. After powering on the partition, press any key ([Space] key, for example) other than the [Enter] key

while the FUJITSU logo is displayed, to display the Boot Manager Front Page.

2. Select the following items from the menu in the following order, on the Boot Manager Front Page:

[Boot Maintenance Manager] - [Boot Options] - [Change Boot Order] - [Change the order]

3. Specify [UEFI:DVD/CD 0] as the highest-priority device to boot from remote storage.

[Change Boot Order] menu FIGURE 4.1

The following table describes the meaning of the menu.

TABLE 4.1 [Change Boot Order] menu

Menu item Description

UEFI: Embedded DVD/CD Specify this item when using the built-in DVD drive for installation in

UEFI mode.

Legacy Boot Specify this item for BIOS mode. Also specify [Legacy Boot] when

using the built-in DVD drive for installation in BIOS mode.

UEFI Shell Do not use this item.

4. Specify [Commit Changes and Exit] - [Reset System] to reboot the partition.

2. Insert ServerView Suite DVD1 into the DVD drive. Then, power on the partition.

104

Page 126: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

105

3. After a moment, the language selection window appears. Select [English] for installation in English.

4. In the initially displayed window, click the [Next] button.

5. Select [Deployment] in the [Welcome to ServerView Installation Manager] window.

6. Select an installation mode and the operating system to be installed. Then, set up the operating system.

7. Click [Install]. Installation begins.

Replace the media with the operating system installation media according to the SVIM instructions.

8. After the installation of the operating system, you will be asked to insert the FJ-LSP DVD. If you have a

SupportDesk Service agreement, insert the FJ-LSP DVD into the remote storage device according to the

instructions.

4.1.3 Making various settings after installation

Make various settings by referring to CHAPTER 5 Work after Operating System Installation (PRIMEQUEST

1800E2) or CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) in the

PRIMEQUEST 1000 Series Installation Manual (C122-E107EN).

4.1.4 Installing HBAnyware

Remarks

For RHEL 5.6 or later, read "HBAnyware" as "OneCommand Manager."

1. Install HBAnyware.

2. The libnl package is required to use HBAnyware. Install the libnl package.

From the webpage at the following URL, download the SNIA HBA API Library, and install it:

http://jp.fujitsu.com/platform/server/primequest/download-e/

Note

Although the downloaded binary file has descriptions referring to PRIMERGY, you can use the

driver and utility for the PRIMEQUEST 1000 series too.

Page 127: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

3. Copy the downloaded file to any directory of the PRIMEQUEST 1000 series server, and extract

files.

4. The following files are extracted:

FIGURE 4.2 SNIA HBA API Library (extracted files)

For details on how to install the SNIA HBA API Library, see readme.txt that has been extracted in

the HBA_API_LIB folder.

5. Install the ETERNUS multipath driver. For details on how to install the driver, see the manual of the

multipath driver.

Remarks

At this time, leave the secondary FC path cable disconnected.

6. Restore the multipath connection.

After completing the installation of the ETERNUS multipath driver, shut down the operating system.

After powering off the partition, reconnect the cable of the FC path that has been disconnected.

Remarks

Use the following procedure to confirm a multipath configuration.

1. Set the HBA UEFI driver. For details, see CHAPTER 2 Settings on the FC Card.

2. Start at the Boot Manager Front Page. Display the following screens in the order given: [Boot

Maintenance Manager] - [Boot Options] - [Change Legacy HDD Boot Priority].

3. Confirm that multiple disks with multiple HBAs are recognized, as shown in the following figure.

If the multiple disks are not recognized, reconfirm that there is no problem in how the multipath

connections were restored.

106

Page 128: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

FIGURE 4.3 [Change Legacy HDD Boot Priority] screen

(confirming a multipath configuration)

4. After confirming that the multiple disks are recognized, start the operating system.

107

Page 129: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

108

4.2 Using the Built-in Disk with RHEL To use the built-in disk, you need make a setting in the UEFI so that the following disk is recognized first as the

start disk: disk with which the SAN boot environment is configured on the ETERNUS machine. Therefore,

after installing the operating system, perform the following additional steps to use the built-in disk.

All screenshots appearing below are display examples whose contents vary depending on the system

configuration, etc.

4.2.1 Checking the disk connection state before mounting the built-in disk

Execute the following command while the partition is operating to check the current disk connection state.

# ls -l /dev/disk/by-id

4.2.2 Mounting the built-in disk

Use the following command to shut down the partition.

# shutdown -h now

After powering off the partition, mount the built-in disk.

4.2.3 Configuring the RAID of the built-in disk (when using the SAS array disk unit)

Initialize the built-in disk inside a RAID configuration, for example, since the built-in disk will be recognized

at the next startup. For details on building a RAID configuration with the built-in hard disk, see the MegaRAID

SAS User's Guide and the MegaRAID SAS Device Driver Installation User Guide.

Page 130: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

4.2.4 Configuring the UEFI

Start the Boot Manager front page. Select [Boot Maintenance Manager] - [Boot Options]- [Change Legacy

HDD Boot Priority]. Then, assign the boot disk that was built on ETERNUS to the top position.

The procedure for making this setting is as follows.

Starting the Boot Manager front page

1. Power on the target partition.

2. After one or two minutes, the window shown below appears. Press any key ([Space] key, for

example) other than the [Enter] key while the FUJITSU logo is displayed.

FIGURE 4.4 Logo at startup

109

Page 131: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

3. The Boot Manager front page appears. Use the down arrow key to select [Boot Maintenance

Manager], which is the option at the bottom. Press the [Enter] key.

FIGURE 4.5 [Boot Manager front page] screen

4. The [Boot Maintenance Manager] screen appears. Select [Boot Options]. Press the [Enter] key.

FIGURE 4.6 [Boot Maintenance Manager] screen

110

Page 132: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

Setting the order of devices

1. The [Boot Options] screen appears. Select [Change Legacy Boot Order], which is the fifth option

from the top. Press the [Enter] key.

FIGURE 4.7 [Boot Options] screen (for setting the order of devices)

2. The [Change Legacy Boot Order] screen appears.

If [DVD/CD Device] immediately follows [Change the order], no change is needed. Press the [Esc]

key several times to exit the Boot Manager front page.

If [DVD/CD Drive] does not immediately follow [Change the order], use the following procedure

so that [DVD/CD Device] immediately follows [Change the order].

111

Page 133: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

3. Select [Change the order]. Press the [Enter] key.

FIGURE 4.8 [Change Legacy Boot Order] screen (for setting the order of devices)

112

Page 134: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

4. The following screen appears. Use the [+] key and [-] key to move [DVD/CD Device] to the top.

Press the [Enter] key.

FIGURE 4.9 [Change Legacy Boot Order] screen (for changing the device order

settings)

5. Press the [Enter] key to return to the previous screen (Figure 4.9 [Change Legacy Boot Order]

screen (for changing the device order settings)). Select [Commit Change and Exit], and then press

the [Enter] key.

113

Page 135: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

Order of HDDs

1. On the [Boot Options] screen, select [Change Legacy HDD Boot Priority], which is the sixth option

from the top. Press the [Enter] key.

FIGURE 4.10 [Boot Options] screen (order of HDDs)

114

Page 136: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2. [Change Legacy HDD Boot Priority] screen appears. Select [Change the order]. Press the [Enter]

key.

FIGURE 4.11 [Change Legacy HDD Boot Priority] screen (order of HDDs)

115

Page 137: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

3. The following screen appears. Use the [+] key and [-] key to move FC to the top. Press the [Enter]

key.

FIGURE 4.12 [Change Legacy HDD Boot Priority] screen (for changing the order of

HDDs)

4. Press the [Enter] key to return to the previous screen ( Figure 4.12 [Change Legacy HDD Boot

Priority] screen (for changing the order of HDDs) ). Select [Commit Change and Exit]. Press the

[Enter] key.

Press the [Esc] key to return to FIGURE 4.5 [Boot Manager front page] screen.

This completes the setting of the boot order.

Configuring an SAS disk as a non-boot device

1. Open [Change the order] from the [Change Legacy HDD Boot Priority] menu.

2. Place the cursor on the SAS disk, and press the [Space] key.

3. The SAS disk becomes a non-boot device, indicated by two slashes ("//") added to the beginning of

the SAS disk name.

If there are multiple SAS disks, repeat the above setting for every SAS disk.

116

Page 138: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

4. Press the [Enter] key to return to the previous screen.

5. Execute [Commit Changes and Exit] to exit.

6. Open [Change Legacy HDD Boot Priority] again for confirmation.

7. Confirm the following:

- All SAS disk names are preceded by two slashes ("//").

- Boot disks are at the top and SAS disks at the bottom of the order.

FIGURE 4.13 [Change Legacy HDD Boot Priority] screen (confirming SAS boot)

Starting the partition and confirming the built-in disk

After completing the UEFI setting, start the partition.

After starting the partition, execute the following command to confirm the difference between the

current state and the state in which the built-in disk had not been mounted yet.

# ls -l /dev/disk/by-id

The disk that was confirmed not to exist before the addition of the built-in disk is the added built-in disk.

117

Page 139: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

118

Creating partitions of the built-in disk

Create disk partitions in the built-in disk, and create a swap file system and other necessary files.

Remarks

Fujitsu recommends you to place the swap partition in the built-in hard disk. For details, contact

your sales representative or a field engineer.

4.2.5 Using a LUN of a non-boot disk

To use a LUN of a non-boot disk such as a data disk, you need to change settings on the ETERNUS side after

operating system installation.

For details on the settings required on the ETERNUS when connecting to it, see the ETERNUS manuals at the

following website:

http://www.fujitsu.com/global/services/computing/storage/eternus/documentation/

4.2.6 Using other disks

To use the system while USB memory or another device recognized as a hard disk is mounted, the disk must be

configured as a non-bootable device. Devices that are recognized as hard disks are added to the [Change

Legacy HDD Boot Priority] menu. For details on how to make a hard disk non-bootable, see 4.2 Using the

Built-in Disk with RHEL.

Page 140: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

119

CHAPTER 5 Installing SUSE Linux Enterprise

Server 11 Service Pack 2 This chapter describes how to install SUSE Linux Enterprise Server 11 Service Pack 2 (referred to below as

SLES11 SP2) on the PRIMEQUEST 1000 series server.

5.1 Installing SLES11 SP2

This section describes how to install SLES11 SP2.

All screenshots appearing below are display examples whose contents vary depending on the system

configuration, etc.

5.1.1 Preparing for SLES11 SP2 installation

Make settings for installation in advance.

For details on this advance setup, see 4.4.1 Advance setup in the PRIMEQUEST 1000 Series Installation

Manual (C122-E107EN).

For a multipath configuration, disconnect the secondary cable connected to the server.

Specifically, use a single path configuration (connection with only one FC cable) until you complete the

installation of the operating system and multipath driver.

If the server is in a multipath connection state, the operating system cannot be installed correctly. Manually

disconnect the secondary FC path beforehand.

Remarks

Disconnect all HDDs, including the built-in HDD, other than the HDD with the installation destination LUN.

You can confirm that all of them are disconnected, by starting the Boot Manager Front Page and selecting [Boot

Maintenance Manager] - [Boot Options] - [Change Legacy HDD Boot Priority].

For details on how to check the connected HDDs, see "How to check the connected HDDs" in 3.1.1 Preparing

for Windows Server 2008/2012 installation.

5.1.2 Installing the OS and bundled software

Use SVIM to install the OS and bundled software.

1. Make the setting for booting the partition from a remote storage device.

Page 141: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

Remarks

If the operating system supports UEFI mode, you can install it in UEFI mode by using the following

procedure to change the boot order.

1. After powering on the partition, press any key ([Space] key, for example) other than the [Enter] key

while the FUJITSU logo is displayed, to display the Boot Manager Front Page.

2. Select the following items from the menu in the following order, on the Boot Manager Front Page:

[Boot Maintenance Manager] - [Boot Options] - [Change Boot Order] - [Change the order]

3. Specify [UEFI:DVD/CD 0] as the highest-priority device to boot from remote storage.

FIGURE 5.1 [Change Boot Order] menu

The following table describes the meaning of the menu.

TABLE 5.1 [Change Boot Order] menu

Menu item Description

UEFI: Embedded DVD/CD Specify this item when using the built-in DVD drive for installation in

UEFI mode.

Legacy Boot Specify this item for BIOS mode. Also specify [Legacy Boot] when

using the built-in DVD drive for installation in BIOS mode.

UEFI Shell Do not use this item.

120

Page 142: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

121

4. Specify [Commit Changes and Exit] - [Reset System] to reboot the partition.

2. Insert ServerView Suite DVD1 into the DVD drive. Then, power on the partition.

3. After a moment, the language selection window appears. Select [English] for installation in English.

4. In the initially displayed window, click the [Next] button.

5. Select [Deployment] in the [Welcome to ServerView Installation Manager] window.

6. Select an installation mode and the operating system to be installed. Then, set up the operating system.

7. Click [Install]. Installation begins.

Replace the media with the operating system installation media according to the SVIM instructions.

5.1.3 Making various settings after installation

Make various settings by referring to CHAPTER 5 Work after Operating System Installation (PRIMEQUEST

1800E2).

Remarks

For details on how to obtain the driver and utility of the Fibre Channel card, contact the distributor where you

purchased your product, or your sales representative.

1. Install the ETERNUS multipath driver. For details on how to install the driver, see the manual of the

multipath driver.

Remarks

At this time, leave the secondary FC path cable disconnected.

2. Restore the multipath connection.

After completing the installation of the ETERNUS multipath driver, shut down the operating system. After

powering off the partition, reconnect the cable of the FC path that has been disconnected.

Page 143: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

Remarks

Use the following procedure to confirm a multipath configuration.

1. Set the HBA UEFI driver. For details, see CHAPTER 2 Settings on the Fiber Channel Card (FC

Card).

2. Start at the Boot Manager Front Page. Display the following screens in the order given: [Boot

Maintenance Manager] - [Boot Options] - [Change Legacy HDD Boot Priority].

3. Confirm that multiple disks with multiple HBAs are recognized, as shown in the following figure.

If the multiple disks are not recognized, reconfirm that there is no problem in how the multipath

connections were restored.

FIGURE 5.2 [Change Legacy HDD Boot Priority] screen (confirming a multipath

configuration)

4. After confirming that the multiple disks are recognized, start the operating system.

122

Page 144: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

123

5.2 Using the Built-in Disk with SLES11 SP2 To use the built-in disk, you need make a setting in the UEFI so that the following disk is recognized first as the

start disk: disk with which the SAN boot environment is configured on the ETERNUS machine. Therefore,

after installing the operating system, perform the following additional steps to use the built-in disk.

All screenshots appearing below are display examples whose contents vary depending on the system

configuration, etc.

5.2.1 Checking the disk connection state before mounting the built-in disk

Execute the following command while the partition is operating to check the current disk connection state.

# ls -l /dev/disk/by-id

5.2.2 Mounting the built-in disk

Use the following command to shut down the partition.

# shutdown -h now

After powering off the partition, mount the built-in disk.

5.2.3 Configuring the RAID of the built-in disk (when using the SAS array disk unit)

Initialize the built-in disk inside a RAID configuration, for example, since the built-in disk will be recognized

at the next startup. For details on building a RAID configuration with the built-in hard disk, see the MegaRAID

SAS User's Guide and the MegaRAID SAS Device Driver Installation User Guide.

Page 145: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

5.2.4 Configuring the UEFI

Start the Boot Manager front page. Select [Boot Maintenance Manager] - [Boot Options]- [Change Legacy

HDD Boot Priority]. Then, assign the boot disk that was built on ETERNUS to the top position.

The procedure for making this setting is as follows.

Starting the Front Manager front page

1. Power on the target partition.

2. After one or two minutes, the window shown below appears. Press any key ([Space] key, for

example) other than the [Enter] key while the FUJITSU logo is displayed.

FIGURE 5.3 Logo at startup

124

Page 146: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

3. The Boot Manager front page appears. Use the down arrow key to select [Boot Maintenance

Manager], which is the option at the bottom. Press the [Enter] key.

FIGURE 5.4 [Boot Manager front page] screen

4. The [Boot Maintenance Manager] screen appears. Select [Boot Options]. Press the [Enter] key.

FIGURE 5.5 [Boot Maintenance Manager] screen

125

Page 147: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

Setting the order of devices

1. The [Boot Options] screen appears. Select [Change Legacy Boot Order], which is the fifth option

from the top. Press the [Enter] key.

FIGURE 5.6 [Boot Options] screen (for setting the order of devices)

2. The [Change Legacy Boot Order] screen appears.

If [DVD/CD Device] immediately follows [Change the order], no change is needed. Press the [Esc]

key several times to exit the Boot Manager front page.

If [DVD/CD Drive] does not immediately follow [Change the order], use the following procedure

so that [DVD/CD Device] immediately follows [Change the order].

126

Page 148: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

3. Select [Change the order]. Press the [Enter] key.

FIGURE 5.7 [Change Legacy Boot Order] screen (for setting the order of devices)

127

Page 149: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

4. The following screen appears. Use the [+] key and [-] key to move [DVD/CD Device] to the top.

Press the [Enter] key.

FIGURE 5.8 [Change Legacy Boot Order] screen (for changing the device order settings)

5. Press the [Enter] key to return to the previous screen (Figure 5.8 [Change Legacy Boot Order]

screen (for changing the device order settings)). Select [Commit Change and Exit], and then press

the [Enter] key.

128

Page 150: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

Order of HDDs

1. On the [Boot Options] screen, select [Change Legacy HDD Boot Priority], which is the sixth option

from the top. Press the [Enter] key.

FIGURE 5.9 [Boot Options] screen (order of HDDs)

129

Page 151: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

2. [Change Legacy HDD Boot Priority] screen appears. Select [Change the order]. Press the [Enter]

key.

FIGURE 5.10 [Change Legacy HDD Boot Priority] screen (order of HDDs)

130

Page 152: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

3. The following screen appears. Use the [+] key and [-] key to move FC to the top. Press the [Enter]

key.

FIGURE 5.11 [Change Legacy HDD Boot Priority] screen (for changing the order of

HDDs)

4. Press the [Enter] key to return to the previous screen ( Figure 5.11 [Change Legacy HDD Boot

Priority] screen (for changing the order of HDDs) ). Select [Commit Change and Exit]. Press the

[Enter] key.

Press the [Esc] key to return to FIGURE 5.4 [Boot Manager front page] screen.

This completes the setting of the boot order.

Configuring an SAS disk as a non-boot device

1. Open [Change the order] from the [Change Legacy HDD Boot Priority] menu.

2. Place the cursor on the SAS disk, and press the [Space] key.

3. The SAS disk becomes a non-boot device, indicated by two slashes ("//") added to the beginning of

the SAS disk name.

4. Press the [Enter] key to return to the previous screen.

5. Execute [Commit Changes and Exit] to exit.

6. Open [Change Legacy HDD Boot Priority] again for confirmation.

131

Page 153: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

7. Confirm the following:

- All SAS disk names are preceded by two slashes ("//").

- Boot disks are at the top and SAS disks at the bottom of the order.

FIGURE 5.12 [Change Legacy HDD Boot Priority] screen (for confirming SAS boot)

Starting the partition and confirming the built-in disk

After completing the UEFI setting, start the partition.

After starting the partition, execute the following command to confirm the difference between the

current state and the state in which the built-in disk had not been mounted yet.

# ls -l /dev/disk/by-id

The disk that was confirmed not to exist before the addition of the built-in disk is the added built-in disk.

Creating partitions of the built-in disk

Create disk partitions in the built-in disk, and create a swap file system and other necessary files.

Remarks

Fujitsu recommends you to place the swap partition in the built-in hard disk. For details, contact

your sales representative or a field engineer.

132

Page 154: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

133

5.2.5 Using a LUN of a non-boot disk

To use a LUN of a non-boot disk such as a data disk, you need to change settings on the ETERNUS side

after operating system installation.

For details on the settings required on the ETERNUS when connecting to it, see the ETERNUS manuals

at the following website:

http://www.fujitsu.com/global/services/computing/storage/eternus/documentation/

5.2.6 Using other disks

To use the system while USB memory or another device recognized as a hard disk is mounted, the disk

must be configured as a non-bootable device. Devices that are recognized as hard disks are added to the

[Change Legacy HDD Boot Priority] menu. For details on how to make a hard disk non-bootable, see 5.2

Using the Built-in Disk with SLES11 SP2.

Page 155: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration

134

CHAPTER 6 Installing VMware For the ESX installation procedure, see the installation guides provided by VMware, Inc.

http://www.vmware.com/support/pubs/

For the ESX servers, FC cards, and driver versions certified by VMware, see the following guides:

Systems Compatibility Guide

I/O Compatibility Guide

Page 156: FUJITSU Server PRIMEQUEST 1000 Seriesmanuals.ts.fujitsu.com/file/10082/c122-e155-04en.pdf · C122-E155-04EN FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration