FRANK L. BENNARDO, P.E. 3 MODULAR ROOMS · 4"Ø itw tapcon maxi-set anchor or 1 4"Ø itw tapcon...
Transcript of FRANK L. BENNARDO, P.E. 3 MODULAR ROOMS · 4"Ø itw tapcon maxi-set anchor or 1 4"Ø itw tapcon...
SEE
SCH
EDU
LESEE
SCH
EDU
LESEE
SCH
EDU
LE40'-0" MAX WALL
SEESCHEDULE
SEESCHEDULE
SEESCHEDULE
SEESCHEDULE
42'-0" MAX ROOF
13'-
0" M
AX R
OO
F12
'-0"
MAX W
ALL
SLOPED ROOF PLAN11 1/4" = 1'-0" PLAN
WALLHEADER,TYP
3" C
OM
POSIT
ERO
OF
PAN
EL,
TYP.
(REF
EREN
CE
FL#
1549
1.1)
D.S. EACORNER, TYP.
O
J
SEE
SCH
EDU
LESEE
SCH
EDU
LE
EXISTING HOSTSTRUCTURE,TYP
OPTIONAL FILLERPANEL AT CORNERPOSTS BASED ONROOM TYPE, TYP.
ATTACHMENT OF GLAZINGPRODUCTS TO MULLIONS TO BE PERSEPARATE PRODUCT APPROVAL OR
SEPARATE ENGINEERING
K
P Q R T
3" PANEL 3" PANEL 3" PANEL
3" PANEL 3" PANEL DRAINAGESYSTEM EACORNER, TYP.
3" COMPOSITEROOF PANEL, TYP.
SLOPED ROOF-SIDE ELEVATION31 1/4" = 1'-0" PLAN
EXISTING HOSTSTRUCTURE,TYP
12'-0" MAX
SEESCHEDULE
SEESCHEDULE
SEESCHEDULE
3"GUTTER,TYP.
GLAZINGPER
SEPARATEAPPROVAL
GLAZINGPER
SEPARATEAPPROVALGLAZING
PERSEPARATEAPPROVAL
P
ELEVATION TYPICAL FORMODULAR ROOMS WITH
GLAZING PRODUCTS
O
J
L N
Q R T
3" PANEL 3" PANEL 3" PANEL 3" PANEL
3" PANEL
3" WALLPANELS, TYP
3" COMPOSITEROOF PANEL, TYP.
SEE EAVE BEAMSCHEDULE
SEE
SCH
EDU
LEFO
R C
OLU
MN
HEI
GH
T
SEESCHEDULE
SEESCHEDULE
SEESCHEDULE
SEESCHEDULE
3" PANEL 3" PANEL 3" PANEL
SLOPED ROOF ELEVATION21 1/4" = 1'-0" ELEVATION
40'-0" MAX WALL
GUTTEREXTRUSION ATPANEL END
ELEVATION TYPICAL FORMODULAR ROOMS WITH
GLAZING PRODUCTS
GLAZINGPER
SEPARATEAPPROVAL
GLAZINGPER
SEPARATEAPPROVAL
GLAZINGPER
SEPARATEAPPROVAL
GLAZINGPER
SEPARATEAPPROVAL
L
DRAINAGESYSTEM EACORNER, TYP.
C D
NG H
B
O P Q R TO P Q R T
STATE SEALINDICATED
BELOW
VALID FOR 1 PERMIT ONLY U.N.O.VALID ONLY WITH ORIGINAL ENGINEER SEAL
THIS
DOC
UMEN
T IS
THE
PRO
PERT
Y OF
ENG
INEE
RING
EXP
RESS
,AN
D SH
ALL N
OT B
E RE
PROD
UCED
IN W
HOLE
OR
PART
WIT
HOUT
WRI
TTEN
CON
SENT
OF
ENGI
NEER
ING
EXPR
ESS.
ALT
ERAT
IONS
,AD
DITI
ONS,
OR
OTHE
R MA
RKIN
GS T
O TH
IS D
OCUM
ENT
ARE
NOT
PERM
ITTE
D AN
D IN
VALID
ATE
OUR
CERT
IFIC
ATIO
N.
OF
REM
ARKS
DRWNCHKD
DATE
SCALE:
COPYRIGHT ENGINEERING EXPRESS®
®
C:\U
sers
\term
user
.FLB
EN
GIN
EE
RIN
G\a
ppda
ta\lo
cal\t
emp\
AcP
ublis
h_72
48\1
6-32
18m
3'' M
odul
ar R
oom
MP
S (2
014
IBC
).dw
g05
/12/
2017
- 8:
53am
term
user
--
--
--
--
--
--
--
--
07/2
5/16
JCF
JCF
INIT
ISSU
E
NTS UNLESS NOTED
6
1
16-3218I
OLD
SM
AR ,
FL
- (8
13)
855-
2627
35
0 BU
RBAN
K R
D
STR
UCTA
LL B
UIL
DIN
G S
YSTE
MS,
INC.
FRANK L. BENNARDO, P.E.
3" MODULAR ROOMSGLASS WALL ROOM SYSTEMS
(SEE SHEET 6 FOR GENERAL NOTES)
**SEE SHEET 6 FOR GENERAL NOTES**
- THIS ENCLOSURE IS ONLY CERTIFIEDAS NON-HABITABLE PER AAMA 2100
- THIS ENCLOSURE DOES NOT QUALIFYFOR MISSILE IMPACT RESISTANCEUNDER ANY CIRCUMSTANCE
" MAX WALLSCHE
2'-0" MAX ROOF
PED ROOF PLA/4" = 1'-0"
ATTACHMENT OF GLAZINGPRODUCTS TO MULLIONS TO BE PESEPARATE PRODUCT APPROVAL O
SEPARATE ENGINEERING
SEE
SCH
EDU
LE
SEESCHEDULE
PLAN
D.S. EACORNER
31 1
3" PANEL
3
OPE
S
GLAZINGPER
SEPARATEAPPRO
3" PANEL
MPOSITEPANEL, TYP.
GLAZINGPER
EPA
ED2100
NOT QUALIFYSISTANCE
ANCE
M
GLAZINGR
EPA
IED210
NOTSIS
TAN
3" PANEL
3
OPE"
S
ATEPRO
S
N
ER
1
D
" MSCHED
2'-0
PED ROOF PLA/4"
EO
CHMENT OF GTO MULLIONPRODUCT A
RATE ENGIN
3" COMPOSITE ROOF PANEL,TYP. (REFERENCE FL#15491.1)OR PER SEPARATE APPROVAL
3" PANEL
3" PANEL
3" PANEL
3" PANEL
3" PANEL
3" PANEL
EXISTING HOST STRUCTUREBY OTHERS, TYP.
EXISTING 3KSI CONCRETE SLAB OR WOOD
DECK (G=0.55 MIN. WOOD) BY OTHERS, TYP.
N.T.S.
ISOMETRICEXPLODED2
1MODULAR ROOM
GLAZING PERSEPARATEAPPROVAL
GLAZING PERSEPARATEAPPROVAL
ISOMETRIC
GLAZING PERSEPARATEAPPROVAL
GLAZING PERSEPARATEAPPROVAL
ATTACHMENT OF GLAZINGPRODUCTS TO MULLIONS
TO BE PER SEPARATEPRODUCT APPROVAL ORSEPARATE ENGINEERING
F
A B
N
C DJ
F
O P
J
F
F
F
F
F
F
L
NL
NL
NL
NL
NL
Q R T
O P Q R T
E
F
2"X3" THERMOMODULAR ROOMMALE MULLION
3" RECEIVING CHANNEL(ALSO USED FORNON-THERMO TOP CAP)
2"X3" MODULARROOM MALEMULLION
K
2"X3" MODULARROOM FEMALEMULLION
L M N 2"X3" THERMOMODULAR ROOMFEMALE MULLION
0.050"TYP.
0.050"TYP.
0.050"TYP.
0.050"TYP.
3.14
0"
1.722"
1.500"
3.14
0"
1.305"
3.16
5
1.500"
3.16
5"
3.240"
0.050"1.
500"
C 3" NON-THERMOBASE CHANNEL
B.1
D 3" THERMO BASECHANNEL
0.053"
1.44
3"
0.045"
3.155"
0.563"
GH
3" KEYED RECEIVER3" WALL NON-THERMOHEADER
3.236"
2.74
3"
1.87
3"
0.065"
0.050"0.045"
0.053"0.050"
3.008"
0.045"
3.260"
0.050"
0.055" 1.50
0"
3" WALL THERMOHEADER
0.702"0.0250"
1.073"
3" THERMO TOP CAPPLATE (UPPERASSEMBLY) B.2
3" THERMO TOP CAPPLATE (LOWERASSEMBLY)
3.218"
0.060"
O P COMPLETE REINFORCEDTHERMO MODULAR MULLIONWITH 3"X3" INSERT
FULL LENGTH3"x3"x1
8" 6063-T6ALUM. INSERT
14" Ø SEX
BOLTS SAEGR. 5 @ 18"O.C. AND 4"FROM ENDS
L
L
N
N
FULL LENGTH3"x3"x1
8" 6063-T6ALUM. INSERT
14" Ø SEX BOLTS SAE
GR. 5 @ 18" O.C.AND 4" FROM ENDS
3.811"
GUTTER EXTRUSIONI4.125"
5.00
0"
0.066"
0.066"
4.06
5"
4.180"
4.18
0"
0.062"
3.180" 1.000"
3" THERMO MODULARROOM CORNER POSTJ
52
CORNERPOSTTIE-DOWNDETAIL
0.050"TYP.3.
140"
2.000" 2.000"
Q 2"X3" NON-THERMOMODULARCOMPLETE MULLIONWITHOUT INSERT
R 2"X3" THERMOMODULARCOMPLETEMULLION WITHOUTINSERT
3.16
5"
3.12
00
1.9800
0.0500
2.9860
3.16
50
S TI-BEAM MULLIONINSERT
COMPLETE REINFORCEDTHERMO MODULARMULLION WITH I-BEAMINSERT
COMPLETE REINFORCEDNON-THERMO MODULARMULLION WITH 3"X3" INSERT
M
M
S
A 3" THERMO TOP CAPCHANNEL
3.250"
3.140"0.055"
0.625"
0.055"
1.37
5"
14" Ø SEX BOLTS SAE
GR. 5 @ 18" O.C.AND 4" FROM ENDS
14" Ø SEX BOLTS
SAE GR. 5 @ 18"O.C. AND 4" FROMENDS
STATE SEALINDICATED
BELOW
VALID FOR 1 PERMIT ONLY U.N.O.VALID ONLY WITH ORIGINAL ENGINEER SEAL
THIS
DOC
UMEN
T IS
THE
PRO
PERT
Y OF
ENG
INEE
RING
EXP
RESS
,AN
D SH
ALL N
OT B
E RE
PROD
UCED
IN W
HOLE
OR
PART
WIT
HOUT
WRI
TTEN
CON
SENT
OF
ENGI
NEER
ING
EXPR
ESS.
ALT
ERAT
IONS
,AD
DITI
ONS,
OR
OTHE
R MA
RKIN
GS T
O TH
IS D
OCUM
ENT
ARE
NOT
PERM
ITTE
D AN
D IN
VALID
ATE
OUR
CERT
IFIC
ATIO
N.
OF
REM
ARKS
DRWNCHKD
DATE
SCALE:
COPYRIGHT ENGINEERING EXPRESS®
®
C:\U
sers
\term
user
.FLB
EN
GIN
EE
RIN
G\a
ppda
ta\lo
cal\t
emp\
AcP
ublis
h_72
48\1
6-32
18m
3'' M
odul
ar R
oom
MP
S (2
014
IBC
).dw
g05
/12/
2017
- 8:
53am
term
user
--
--
--
--
--
--
--
--
07/2
5/16
JCF
JCF
INIT
ISSU
E
NTS UNLESS NOTED
6
2
16-3218I
OLD
SM
AR ,
FL
- (8
13)
855-
2627
35
0 BU
RBAN
K R
D
STR
UCTA
LL B
UIL
DIN
G S
YSTE
MS,
INC.
FRANK L. BENNARDO, P.E.
1/4” SAE GR 5 THRUBOLTSMAY BE USED IN LIEU OF SEX
BOLTS IN ALL CASES
N 2"X3" THEMODUFE
0.050"TYP.
1.500"
0.0
L
4.180"
3" THERMO MODULARROOM CORNER POSTJ
52
2"X3" MODULARROOM MALE
ONK
0.05T
3.14
0"
22"
FULL LENGT3"x3"x1
8" 6ALUM. INSE
N
3" PANEL
EXISTING 3KSI CODECK (G=0.55 M
ERRRRTE
OVAL
F
NL
NEL
PANEL
GLAZING PERRRRSEPARATEAPPROVAL
F
N
O P Q
3" COMPOSITE RTYP. (REFERENCOR PER SEP
CTUREYP.
F
RENC
EPA
CTUYP.
NE
P
F
N
Q
3
TING 3KSI COCK (G=0.55 M
ERRRRATEROV
F
ROOM ON
722
T6E
W
05T
N THEDU
FEM
2
0
" THERMOROOM CORN
EXISTING WOOD TRUSSOR RAFTER (G=0.55
MIN WOOD) BY OTHERS.PROVIDE (4)-#14
WOOD SCREWS ATEACH RAFTER END WITH
212" THREAD
PENETRATION, 34" EDGEDISTANCE.
3" SNAP-N-LOCKCOMPOSITE PANELPER SEPARATE ENG
(2)-#14 WOOD SCREWSWITH 1"Ø WASHER, 11
2"MIN. THREAD PENETRATIONTO FASCIA, 34" EDGE DIST.,1" MIN. SPACING PER PAIR.SPACE ANCHOR PAIRS AT
1112" MAX O.C., TYP.
EXISTING WOODFASCIA (G=0.55 MIN.)WOOD, TYP.
WOOD HOST SECTION3
5
3" SNAP-N-LOCKCOMPOSITE PANELPER SEPARATE ENG
14"Ø ITW TAPCON MAXI-SET
ANCHOR OR 14"Ø ITWTAPCON WITH 1"Ø WASHER,
134" EMBED TO 3KSI
CONCRETE, 212" EDGE DIST.,
SPACED AT 938" O.C. OR 14"Ø
ELCO ULTRACON WITH 1"ØWASHER, 21
4" EMBED TOGROUT FILLED BLOCK, 21
2"EDGE DIST., SPACED AT 7"
O.C. (DO NOT SPACEANCHOR CLOSER THAN 41
4"TO ANY ADJACENT
CONCRETE/BLOCK ANCHOR).
EXISTING 3KSI CONCRETEOR HOLLOW BLOCK (ASTMC-90 BLOCK) HOSTSTRUCTURE, TYP.
CONC. OR BLOCK HOSTSECTION3
6
3" SNAP-N-LOCKCOMPOSITE PANELPER SEPARATE ENG
EXISTING WOODDECK (G=0.55 MIN.WOOD) OR 3KSICONCRETE SLAB, TYP.BY OTHERS
WALL PANEL TO HOST BASESECTION3
9
#14 WOOD SCREW WITH 1"ØWASHER, 2" MIN. THREADPENETRATION, 34" EDGE DIST.,AT 63
4" MAX O.C. OR 14"Ø ITWTAPCONS WITH 1"Ø WASHER,13
4" EMBEDMENT, 212" EDGE
DIST., SPACED AT 10" O.C.
#12 SAE GRADE 5SHEET METALSCREWS AT 12" O.C.EA SIDE, TYP.
#12 SAE GRADE 5SHEET METALSCREWS AT 12" O.C.EA SIDE, TYP.
#12 SAE GRADE 5SHEET METAL
SCREWS AT 12" O.C.EA SIDE, TYP.
ROOF DETAILSECTION3
3FAN BEAM IN PANEL
PANEL FILLSECTION3
11ROOF PANEL TO
ROOF PANEL TO
HEAD/SILL
3" SNAP-N-LOCKCOMPOSITE PANEL
PER SEPARATEENG
#12 SAE GRADE 5SHEET METALSCREWS AT 12" O.C.EA SIDE, TYP.
WINDOW PERMANUFACTURERSSPECS
3" SNAP-N-LOCKCOMPOSITE PANELPER SEPARATE ENG
50LB MAXIMUM FANOR LIGHT FIXTURE,TYP.
CONTINUOUS 112"x3"x0.05"
6063-T6 ALUMINUM FANBEAM, TYP.
L N
G H
G H
C D
F
3" SNAP-N-LOCK COMPOSITEPANEL PER SEPARATE ENG
N.T.S.
HOST SIDE WALLPLAN VIEW3
7
#14 WOOD SCREW WITH 1"ØWASHER, 11
2" MIN. THREADPENETRATION, 34" EDGE DIST.OR 14"Ø ITW TAPCONS WITH1"Ø WASHER (14"Ø MAXI-SETTAPCON OPTIONAL), 13
4"EMBEDMENT, 21
2" EDGE DIST.OR 14"Ø ELCO ULTRACON WITH1"Ø WASHER, 21
4" EMBEDMENT,21
2" EDGE DIST., SPACED AT24" MAX O.C. (DO NOT SPACECONCRETE/BLOCK ANCHORSCLOSER THAN 41
2" O.C.).
14" Ø SAE GRADE 5 SEX BOLTS
AT 18" O.C. AND 4" FROMENDS, TYP.
WALL PANEL TO
E
HOSTSTRUCTUREBY OTHERS
N.T.S.
PANEL FILLPLAN VIEW3
12WIND JAMB AT
3" SNAP-N-LOCKCOMPOSITE PANELPER SEPARATE ENG WINDOW PER
MANUFACTURERSSPECS
LF
14" Ø SAE GRADE 5
SEX BOLTS AT 18"O.C. AND 4" FROMENDS, TYP.
N.T.S. N.T.S. N.T.S.
N.T.S.
3" SNAP-N-LOCKCOMPOSITE PANELPER SEPARATE ENG
3" SNAP-N-LOCKCOMPOSITE PANELPER SEPARATE ENG
CONTINUOUS 14"BEAD OFELASTOMERICSEALANT, TYP.
N.T.S.
AT EAVESECTION3
1
14"Ø SAE GRADE 5 SMS WITH 58"Ø INTEGRATEDALUMINUM/NEOPRENE WASHER. UTILIZE 11
2"ØALUMINUM/NEOPRENE WASHER & PROVIDE 5
PINCHES MIN. PAST THE WALL TOPCAP THREADPLANE SPACED WITH 6.0" O.C.
ROOF TO WALL PANEL
#12 SAE GRADE 5SHEET METAL
SCREWS AT 10"O.C., TYP.
PROVIDE (2)-1/2"THICK CONTINUOUS
BEADS OF 400 PSISTRUCTURAL GRADE
ADHESIVE TO ATTACHPANEL TO TOP CAP
ASSEMBLY, TYP.
B
L N
MIN
6"
EAVE
BEA
M P
ERTA
BLE
1
14" Ø SAE GRADE 5SEX BOLTS AT 18"O.C. AND 4" FROM
ENDS, TYP.
N.T.S.
DETAILSECTION3
4ROOF PANEL GUTTER
3" SNAP-N-LOCKCOMPOSITE PANELPER SEPARATE ENG
I
#12 SAE GRADE 5SHEET METAL
SCREWS AT 12" O.C.AND 4" FROM ENDS
EA SIDE, TYP.
N.T.S.
AT RAKESECTION3
2ROOF TO WALL PANEL
3" SNAP-N-LOCKCOMPOSITEPANEL PER
SEPARATE ENG.
3" SNAP-N-LOCKCOMPOSITE PANELPER SEPARATE ENG
14"Ø SAE GRADE 5 SMS WITH 58"Ø INTEGRATED
ALUMINUM/NEOPRENE WASHER. UTILIZE 112"Ø
ALUMINUM/NEOPRENE WASHER & PROVIDE 5PINCHES MIN. PAST THE WALL TOPCAP THREADPLANE AT 10" MAX O.C., TYP.
#12 SAE GRADE 5SHEET METALSCREWS AT 10"O.C., TYP.
PROVIDE (2)-1/2"THICK CONTINUOUS
BEADS OF 400 PSISTRUCTURAL GRADE
ADHESIVE TO ATTACHPANEL TO TOP CAP
ASSEMBLY, TYP.
A
E L
MIN
6"
EAVE
BEA
M P
ERTA
BLE
1
N1
4" Ø SAE GRADE 5SEX BOLTS AT 18"O.C. AND 4" FROM
ENDS, TYP.
3" SNAP-N-LOCK COMPOSITEPANEL PER SEPARATE ENG
3" SNAP-N-LOCKCOMPOSITE PANELPER SEPARATE ENG
N.T.S.
CORNER COLUMN DETAILPLAN3
8
I
14" Ø SAE GRADE 5 SEX BOLTS
AT 18" O.C. AND 4" FROMENDS, TYP.
14"Ø SAE GRADE 5 SMS
SEE DETAIL 1/3 FORMORE INFORMATION
14"Ø SAE GRADE 5 SEX
BOLT WITH 14" SAEGRADE WASHER AND NUT
THROUGH TOP CAPCHANNEL TO CORNER
POST, TYP.
(1)-#12 SAE GRADE 5 SMSTHROUGH KEYED RECEIVER
TO PANEL EACH SIDE OFPOST, TYP.
OPTIONAL2"x2"x0.063"x2"LONG 6063-T6ALUMINUM ANGLEEA SIDE OF POST(SEE DETAIL 4/4 FORCLIP ANCHORS), TYP
SEE DETAIL 2/4 FOR TYPICALSMS ANCHOR NOTATION FORTHE ANCHORS ILLUSTRATED
HEREIN, TYP.
N.T.S.
TO TOPCAP CONNECTIONELEVATION3
10CORNER POST
J
A B
L N E
STATE SEALINDICATED
BELOW
VALID FOR 1 PERMIT ONLY U.N.O.VALID ONLY WITH ORIGINAL ENGINEER SEAL
THIS
DOC
UMEN
T IS
THE
PRO
PERT
Y OF
ENG
INEE
RING
EXP
RESS
,AN
D SH
ALL N
OT B
E RE
PROD
UCED
IN W
HOLE
OR
PART
WIT
HOUT
WRI
TTEN
CON
SENT
OF
ENGI
NEER
ING
EXPR
ESS.
ALT
ERAT
IONS
,AD
DITI
ONS,
OR
OTHE
R MA
RKIN
GS T
O TH
IS D
OCUM
ENT
ARE
NOT
PERM
ITTE
D AN
D IN
VALID
ATE
OUR
CERT
IFIC
ATIO
N.
OF
REM
ARKS
DRWNCHKD
DATE
SCALE:
COPYRIGHT ENGINEERING EXPRESS®
®
C:\U
sers
\term
user
.FLB
EN
GIN
EE
RIN
G\a
ppda
ta\lo
cal\t
emp\
AcP
ublis
h_72
48\1
6-32
18m
3'' M
odul
ar R
oom
MP
S (2
014
IBC
).dw
g05
/12/
2017
- 8:
53am
term
user
--
--
--
--
--
--
--
--
07/2
5/16
JCF
JCF
INIT
ISSU
E
NTS UNLESS NOTED
6
3
16-3218I
OLD
SM
AR ,
FL
- (8
13)
855-
2627
35
0 BU
RBAN
K R
D
STR
UCTA
LL B
UIL
DIN
G S
YSTE
MS,
INC.
FRANK L. BENNARDO, P.E.
1/4” SAE GR 5 THRUBOLTSMAY BE USED IN LIEU OF SEX
BOLTS IN ALL CASES
14"Ø ITW TAPC
ANCHORAPCON WITH
134" EM
ONCRETE, 212
PACED AT 938
ELCO ULTRAWASHER,
GROUT FILEDGE DIS
O.CANCHOR
CONCR
PANEL
3" SNAP-N-COMPOSITEPER SEPARA
0LB MAXIMUM FANR LIGHT FIXTURE,YP.
SECTI
L PANEL
WSER, 11
2"ETRATION
4" EDGE DIST.,PACING PER PAIR.
ANCHOR PAIRS A11
2" MAX O.C.
WOOD HOST S3
5
XI-SET"Ø ITWASHER,O 3KSIDIST.,
OR 14"ØTH 1"ØBED TOK, 21
2"D AT
EXISTIOR
ROOF PANEL
G H
N-LOCKITE PANELARATE ENG
C.
/4” SAE GMAY BE USE
BOLTS IN
LLPLAN VIEW
PACECHORS
" O.C.).
3" SNAPANEL
14"
AT EN
SS
NA
S3 FOR
RMATION
UTOP CAP
O CORNERPOST, TYP.
E GRADE 5 SMEYED RECEIVEL EACH SIDE O
POST, TY
DETAIL 2/4 FOR TYPICALANCHOR NOTATION FORANCHORS ILLUSTRATED
EREIN, TYP.
TOPCARNER P
J
MS3 FO
RMA
SNA
UTOP C
O C
E GRADE 5 SMEYED RECEIVEL EACH SIDE O
Y
DETAIL 2/4 FOANCHOR NOTAANCHORS ILL
E
TOPCAPRNER PO
ALLW
PACNCH
2" O
PP
END
SST
NITA
EWSER,
NET4" E
PACA
1
STS
X"AO
OTBC 2"D AT S
STINOR
C
L
GEDN
1/4” M
G
.S A
C.
OOOF PA
CR
M2
8A
R, L
ST.C
OR
CR
PANEL
0RY
L PA1
TA
OP
LEA
I
6" MIN SNAP-N-LOCKEAVE BEAM, TYP.
14"Ø SAE GRADE 5 SHEET METAL SCREW
SEE DETAIL 1/3 FOR MORE INFORMATION
6" M
IN.
L
UTILIZE (2)-#12x114" LONG SAE
GRADE 5 SMS EACH SIDE OFMULLION TO FEMALE MULLION
SCREW BOSS, TYP.
N.T.S.
OPTION #1SECTION4
1CONNECTION AT EAVE & POST
N.T.S.
OPTION #1ELEVATION4
2CONNECTION AT EAVE & POST
PROVIDE (2)-1/2" THICK CONTINUOUSBEADS OF 400 PSI STRUCTURAL GRADEADHESIVE TO ATTACH PANEL TO TOP CAPASSEMBLY, TYP.
N
B E
O P
14" Ø SAE GRADE 5 SEX BOLTS
WITH SAE GRADE WASHERTHROUGH TOP CAP CHANNEL
TO POST, TYP.
6" MIN. DEEPSNAP-N-LOCK EAVEBEAM, TYP.
14"Ø SAE GRADE 5 SMS SEE
DETAIL 1/3 FOR MOREINFORMATION
SPACEPER
DETAIL1/3
UTILIZE (2)-#12x114" LONG SAE
GRADE 5 SMS EACH SIDE OFMULLION TO FEMALE MULLION
SCREW BOSS, TYP.
6" MIN
.
14" Ø SAE GRADE 5SEX BOLTS AT 18"MAX O.C. AND 4"FROM ENDS, TYP.
41
B E
F
L N
14" Ø SAE GRADE 5 SEX BOLTS
THROUGH CHANNELS TOKEYED RECEIVER EA SIDE OF
POST AT TOP AND BOTTOM OFEAVE (4 BOLTS TOTAL)
SEE POSTS O, P, Q, R AND TON SHEET 2 FOR STICHING
REQUIREMENTS (REINFORCEDPOST SHOWN)
14" Ø SAE GRADE 5 SEX BOLTS
THROUGH CHANNELS TOKEYED RECEIVER EA SIDE OF
POST AT TOP AND BOTTOM OFEAVE (4 BOLTS TOTAL)
Q R TO P Q R T (* O OR P SHOWN)
STATE SEALINDICATED
BELOW
VALID FOR 1 PERMIT ONLY U.N.O.VALID ONLY WITH ORIGINAL ENGINEER SEAL
THIS
DOC
UMEN
T IS
THE
PRO
PERT
Y OF
ENG
INEE
RING
EXP
RESS
,AN
D SH
ALL N
OT B
E RE
PROD
UCED
IN W
HOLE
OR
PART
WIT
HOUT
WRI
TTEN
CON
SENT
OF
ENGI
NEER
ING
EXPR
ESS.
ALT
ERAT
IONS
,AD
DITI
ONS,
OR
OTHE
R MA
RKIN
GS T
O TH
IS D
OCUM
ENT
ARE
NOT
PERM
ITTE
D AN
D IN
VALID
ATE
OUR
CERT
IFIC
ATIO
N.
OF
REM
ARKS
DRWNCHKD
DATE
SCALE:
COPYRIGHT ENGINEERING EXPRESS®
®
C:\U
sers
\term
user
.FLB
EN
GIN
EE
RIN
G\a
ppda
ta\lo
cal\t
emp\
AcP
ublis
h_72
48\1
6-32
18m
3'' M
odul
ar R
oom
MP
S (2
014
IBC
).dw
g05
/12/
2017
- 8:
53am
term
user
--
--
--
--
--
--
--
--
07/2
5/16
JCF
JCF
INIT
ISSU
E
NTS UNLESS NOTED
6
4
16-3218I
OLD
SM
AR ,
FL
- (8
13)
855-
2627
35
0 BU
RBAN
K R
D
STR
UCTA
LL B
UIL
DIN
G S
YSTE
MS,
INC.
FRANK L. BENNARDO, P.E.
1/4” SAE GR 5 THRUBOLTSMAY BE USED IN LIEU OF SEX
BOLTS IN ALL CASES
L
ON #1NECTION AT EAVE
N
O P Q
SECTION
POST
I
6" MIN
.
SAE GRADE 5BOLTS AT 18"
AX O.C. AND 4"ROM ENDS, TYP.
GRADE 5 SEX BOLTSOUGH CHANNELS TO
RECEIVER EA SIDE OFTOP AND BOTTOM OF
EAVE (4 BOLTS TOTAL)
, Q, R AND FOR STICHING
TS (REINFORCEDPOST SHOWN)
PACEPER
DETAIL1/3
SPA
S
P
I
2)
X A
ROM ENDS, TYP.
GO
RET
EA
, Q, R AND 2 FOR STICHINGTS (REINFORCED
D
SHA
R EAD BOTBOLTS
L
INECTION AT EAVE
N
Q
1
VELOCITY & EXPOSURE UPLIFT GRAVITY MAX ROOF SPAN MAX EAVE BEAM SPAN
90 MPH, "B" THROUGH 100 MPH,EXP "C" & 110 MPH EXP "B"
22.5 PSF 36.5 PSF 12.00 FT 5.00 FT
110 MPH, "C" & 120 MPH "B" 22.5 PSF 36.5 PSF 12.00 FT 5.00 FT120 MPH, "C" 22.5 PSF 36.5 PSF 12.00 FT 5.00 FT
3" MODULAR ROOM EAVE BEAM: GLAZED WALL SYSTEMSTABLE 1:
1. MAX ALLOWABLE EAVE BEAM SPAN= 5'-0"2. MAX ALLOWABLE ROOF SPAN= 12'-0"3. DEFLECTION LIMIT = L/180.4. EAVE BEAMS DEEPER THAN 6" MAY BE USED
TABLE 1 NOTES:
DESCRIPTIONANCHORTYPE
WINDTIER
ANCHOR# 1 SCHEDULE A:
90 "B"-TO-
110 "B"
110 "C"-TO-
120 "C"
1
1
(1)- 14"Ø SAE GRADE 5 SEX BOLT WITH1/4" SAE GRADE WASHER
(1)-3/8"Ø SAE GRADE 5 SEX BOLT WITH3/8" SAE GRADE WASHER
QUANTITY REQUIREDANCHOR 2SUBSTRATE
WINDTIER
ANCHOR #2 SCHEDULE B:
90 "B"-TO-
110 "B"
CONNECTIONAT CONCRETE
(2)-3/8"Ø ITW TAPCONS WITH 112"Ø WASHER,
212" EMBED, 3" EDGE, 4" SPACING, TYP.
CONNECTIONAT WOOD
110 "C"-TO-
120 "C"
(3)-1/4"Ø LAG SCREWS 112"Ø WASHER, 21
2"THREAD PENETRATION, 1" EDGE, 1" SPACING
CONNECTIONAT CONCRETE
CONNECTIONAT WOOD
(4)-1/4"Ø LAG SCREWS 112"Ø WASHER, 21
2"THREAD PENETRATION, 1" EDGE, 1" SPACING
N.T.S. DETAIL52 FOR GLASS WALL SYSTEMS
TYPICAL POST CONNECTION
EXISTING 3KSICONCRETE OR WOOD(G=0.55 MIN.) HOSTSTRUCTURE BYOTHERS, TYP.
3" SNAP-N-LOCKPANEL, TYP. PERSEPARATE ENG
EMBED
PER
SCH
ED
ANCHOR #1: SEESCHEDULE A
ANCHOR #2: SEESCHEDULE B
SEE SCHEDULE FORANCHOR INFO AND
QUANTITIESREQUIRED, TYP.
SEE DETAIL 9/3 FORTYPICAL ANCHOR TYPEAND SPACING
SEE DETAIL 9/3 FOR TYPICALANCHOR TYPE AND SPACING
F
C D
O P Q R T
(2)-3/8"Ø ITW TAPCONS WITH 112"Ø WASHER,
212" EMBED, 3" EDGE, 4" SPACING, TYP.
SEE SHEET 2FOR SEX BOLTREQUIREMENTSFOR STITCHING
14" Ø SAE GRADE 5 SEX BOLTS
THROUGH KEYED RECEIVER TOPANEL, TYP.
(4)-5/16"Ø SEX BOLTS THROUGHKEYED RECEIVER TO MULLION,
TYP.
3" = 1'-0"
TIE-DOWN FOR ALL SYSTEMSDETAIL5
1TYPICAL CORNER POST
UTILIZE (3)-#12 SAEGRADE 5 SMS THROUGHEACH CLIP ANGLE TOPOST, TYP.
2"x2"x0.063"x2"LONG 6063-T6ALUMINUM ANGLE,(1) EA SIDE OFPOST ON THEINSIDE FACE (2CLIPS TOTAL). SEEPLAN VIEW A-A FORPLACEMENTINFORMATION, TYP.
(1)- 14"Ø ITW TAPCON WITH 112"Ø
WASHER PER ANGLE, 214" EMBED,
318" EDGE, 33
4" MIN. SPACING TOANY ADJACENT CONCRETE ANCHOROR (4)-1/4"Ø LAG SCREWS WITH 1"ØWASHER, 21
2" THREADPENETRATION, 1" EDGE DISTANCE,1" MIN. SPACING TO ANY ADJACENTWOOD ANCHOR, TYP.
33 4"
MIN
PLAN VIEWA-A
AA
J
C D
J
14" Ø SAE GRADE 5 SEX BOLTS WITHSAE GRADE WASHER THROUGH TOP
CAP CHANNEL TO POST, TYP.
EAVEBEAMSPAN
EAVEBEAMSPAN
EAVEBEAMSPAN
ROOF
SPAN
* GLAZING NOT SHOWNFOR CLARITY
EAVE BEAM CLEAR SPANISOMETRIC DETAIL*
N.T.S.
SPACING ISOMETRICISOMETRIC5
4EAVE-BEAM
STATE SEALINDICATED
BELOW
VALID FOR 1 PERMIT ONLY U.N.O.VALID ONLY WITH ORIGINAL ENGINEER SEAL
THIS
DOC
UMEN
T IS
THE
PRO
PERT
Y OF
ENG
INEE
RING
EXP
RESS
,AN
D SH
ALL N
OT B
E RE
PROD
UCED
IN W
HOLE
OR
PART
WIT
HOUT
WRI
TTEN
CON
SENT
OF
ENGI
NEER
ING
EXPR
ESS.
ALT
ERAT
IONS
,AD
DITI
ONS,
OR
OTHE
R MA
RKIN
GS T
O TH
IS D
OCUM
ENT
ARE
NOT
PERM
ITTE
D AN
D IN
VALID
ATE
OUR
CERT
IFIC
ATIO
N.
OF
REM
ARKS
DRWNCHKD
DATE
SCALE:
COPYRIGHT ENGINEERING EXPRESS®
®
C:\U
sers
\term
user
.FLB
EN
GIN
EE
RIN
G\a
ppda
ta\lo
cal\t
emp\
AcP
ublis
h_72
48\1
6-32
18m
3'' M
odul
ar R
oom
MP
S (2
014
IBC
).dw
g05
/12/
2017
- 8:
53am
term
user
--
--
--
--
--
--
--
--
07/2
5/16
JCF
JCF
INIT
ISSU
E
NTS UNLESS NOTED
6
5
16-3218I
OLD
SM
AR ,
FL
- (8
13)
855-
2627
35
0 BU
RBAN
K R
D
STR
UCTA
LL B
UIL
DIN
G S
YSTE
MS,
INC.
FRANK L. BENNARDO, P.E.
1/4” SAE GR 5 THRUBOLTSMAY BE USED IN LIEU OF SEX
BOLTS IN ALL CASES
CRIPTION
LE A:
RADE 5 SEX BOLT WITHE WASHER
GRADE 5 SEX BOLT WITHE WASHER
A
N.T.S52 FOR GLASS WA
TYPICAL POST
DR
HOR #
DET
L SYSTONNECTION
EXICON(G=0.STRUCTOTHERS
EMBEDED
M PERER
SCH
EDDCH
SEE DTYPAN
C D
SIOR WOODN.) HOST
E BYYP.
FORR TYPE
UPLIF
H 100 MPH,PH EXP "B"
22.5 P
C" & 120 MPH "B"120 MPH, "C"
AM: G
AX ALLOWABLE EAAX ALLOWABLEFLECTION LIMVE BEAMS DE
LE 1 NOTES
GRAVITY MAX ROOF S
36.5 PSF 12.00 FT
12.00 FT12.00 FT
ED WALL SYSTEMS
S
T
GRAVITY
36.5 PSF
12.00 FT12.00 FT
ZED WALL SY
UPLIF
H 10MPH
P
"C" 1
AM: GL
AX ALLOWABLE EAAX ALLOWABLEEFLECTION LIMVE BEAMS DE
BLE 1 NOTES
DR
HOR #
ETA
L SYSTEMSONNECTION
XISTING 3KSNCRETE O0.55 MINCTURE
S, TY
DETAIL 9/3 FOPICAL ANCHOR
AN
C
L
GE
GD
A
AT
BOLT WITH
S
R GLA
TABLE 2:GLASS ALLOWABLE POST HEIGHT (3X3 INSERT): 120MPH, Exp 'C'
TABLE 3:GLASS ALLOWABLE POST HEIGHT (3X3 INSERT): 110MPH, Exp 'C', 120MPH, EXP 'B'
TABLE 4:GLASS ALLOWABLE POST HEIGHT (3X3 INSERT): 90MPH, Exp 'B' THROUGH 100 MPH, EXP 'C' & 110 MPH, EXP 'B'
TABLE 5:GLASS ALLOWABLE POST HEIGHT (I-BEAM INSERT): 120MPH, Exp 'C'
TABLE 6:
TABLE 7:GLASS ALLOWABLE POST HEIGHT (I-BEAM INSERT): 90MPH, Exp 'B' THROUGH 100 MPH, EXP 'C' & 110 MPH, EXP 'B'
TABLE 8:GLASS ALLOWABLE POST HEIGHT (NO INSERT): 120 MPH, EXP 'C''
TABLE 9:GLASS ALLOWABLE POST HEIGHT (NO INSERT): 110 MPH, EXP 'C', 120 MPH, EXP 'B'
TABLE 10:GLASS ALLOWABLE POST HEIGHT (NO INSERT): 90 MPH, EXP 'B', THROUGH 100 MPH, EXP 'C' & 110 MPH, EXP 'B'
GLASS ALLOWABLE POST HEIGHT (I-BEAM INSERT): 110MPH, Exp 'C', 120MPH, EXP 'B'
OPJ
OPJ
OPJ
TJ
TJ
TJ
QRJ
QRJ
QRJ
ROOF
SPAN
*GLAZING NOT SHOWNFOR CLARITY
POST SPACINGISOMETRIC DETAIL*
SPAN 1SPAN 2
SPAN 3
POST 1POST 2CORNER
POST
POST 2SPACING=
(12*SPAN 2)+(12*SPAN 3)
CORNER POSTSPACING=(12*SPAN 1)
N.T.S.
POST SPACING ISOMETRICISOMETRIC6
1
1. THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE STRUCTURAL PROVISIONS OF THE2012 & 2015 INTERNATIONAL BUILDING CODE & 2012 & 2015 INTERNATIONAL RESIDENTIAL CODE AS WELL AS CURRENT VERSIONSOF THE MN, NC, NJ, NY, OH, SC, VA BUILDING & RESIDENTIAL CODES AS APPLICABLE. STRUCTURE SHALL BE FABRICATED INACCORDANCE WITH ALL GOVERNING CODES. CONTRACTOR SHALL INVESTIGATE AND CONFORM TO ALL LOCAL BUILDING CODEAMENDMENTS WHICH MAY APPLY.
2. NO 33-1/3% INCREASE IN ALLOWABLE STRESS HAS BEEN USED IN THE DESIGN OF THIS SYSTEM. WIND LOAD DURATIONFACTOR Cd=1.6 HAS BEEN USED FOR WOOD ANCHOR DESIGN.
3. THE ARCHITECT/ENGINEER OF RECORD FOR THE PROJECT SUPERSTRUCTURE WITH WHICH THIS DESIGN IS USED SHALL BERESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL BE COORDINATED BY THEPERMITTING CONTRACTOR.
4. OPENINGS IN SUNROOMS, BALCONIES OR ENCLOSED PORCHES CONSTRUCTED UNDER EXISTING ROOFS OR DECKS ARE NOTREQUIRED TO BE PROTECTED PROVIDED THE SPACES ARE SEPARATED FROM THE BUILDING INTERIOR BY A WALL AND ALL OPENINGSIN THE SEPARATING WALL ARE PROTECTED IN ACCORDANCE WITH SECTION 1609.1.2 ABOVE. SUCH SPACES SHALL BE PERMITTEDTO BE DESIGNED AS EITHER PARTIALLY ENCLOSED OR ENCLOSED STRUCTURES.
5. ALL FASTENERS TO BE #12 OR GREATER SAE GRADE 5 UNLESS NOTED OTHERWISE. FASTENERS SHALL BE CADMIUM-PLATEDOR OTHERWISE CORROSION-RESISTANT MATERIAL AND SHALL COMPLY WITH "SPECIFICATIONS FOR ALUMINUM STRUCTURES"SECTION J.3.1 BY THE ALUMINUM ASSOCIATION, INC., & ANY APPLICABLE FEDERAL, STATE, AND/OR LOCAL CODES.
6. ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS. MINIMUM EMBEDMENT SHALLBE AS NOTED HEREIN. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDES STUCCO, FOAM, BRICK, AND OTHER WALL FINISHES.
7. ALL CONCRETE ANCHORS SHALL BE INSTALLED TO NON-CRACKED CONCRETE ONLY.8. THE CONTRACTOR IS RESPONSIBLE TO INSULATE ALL MEMBERS FROM DISSIMILAR MATERIALS TO PREVENT ELECTROLYSIS.9. ALL ALUMINUM SHALL BE 6063-T6 ALLOY AND TEMPER UNLESS NOTED OTHERWISE.10. ALL CONCRETE TO REACH A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI IN 7 DAYS.11. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY
CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES &APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, & CONSTRUCTION PRACTICES BEYOND THAT WHICHIS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN.
12. THIS ENGINEER HAS NOT VISITED THIS JOBSITE. INFORMATION CONTAINED HEREIN IS BASED ON CONTRACTOR SUPPLIEDDATA AND MEASUREMENTS. THIS ENGINEER SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS ORINACCURATE DATA OR MEASUREMENTS. WORK SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION. THIS ENGINEER SHALL BENOTIFIED AND GIVEN AN OPPORTUNITY TO REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION PRIOR TOMODIFICATION OF EXISTING FIELD CONDITIONS AND FABRICATION AND INSTALLATION OF MATERIALS.
13. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED.14. ALTERATIONS, ADDITIONS, HIGHLIGHTING, OR OTHER MARKINGS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE
THIS CERTIFICATION.
GENERAL NOTES:
2012 AND 2015 INTERNATIONAL BUILDING CODE, ASCE 7-10Vult=VARIES PER DESIGN SCHEDULES, EXPOSURES 'C & C'RISK CATEGORY II, G=0.85, Kd=TABLE 30.3-1, Kz=0.85, Kzt=1.0(FLAT OR UNOBSTRUCTED TERRAIN ONLY)qh = 0.00256*Kz*Kzt*Kd*V*VP = qh((GCp)-(GCpi))
MRH= 15'ROOF LIVE LOAD: 30 PSFROOF DEAD LOAD: 2 PSF
*THIS DOCUMENT DOES NOT CERTIFY PRODUCT FOR USE AS A HABITABLE STRUCTURE.
DESIGN NOTES: STATE SEALINDICATED
BELOW
VALID FOR 1 PERMIT ONLY U.N.O.VALID ONLY WITH ORIGINAL ENGINEER SEAL
THIS
DOC
UMEN
T IS
THE
PRO
PERT
Y OF
ENG
INEE
RING
EXP
RESS
,AN
D SH
ALL N
OT B
E RE
PROD
UCED
IN W
HOLE
OR
PART
WIT
HOUT
WRI
TTEN
CON
SENT
OF
ENGI
NEER
ING
EXPR
ESS.
ALT
ERAT
IONS
,AD
DITI
ONS,
OR
OTHE
R MA
RKIN
GS T
O TH
IS D
OCUM
ENT
ARE
NOT
PERM
ITTE
D AN
D IN
VALID
ATE
OUR
CERT
IFIC
ATIO
N.
OF
REM
ARKS
DRWNCHKD
DATE
SCALE:
COPYRIGHT ENGINEERING EXPRESS®
®
C:\U
sers
\term
user
.FLB
EN
GIN
EE
RIN
G\a
ppda
ta\lo
cal\t
emp\
AcP
ublis
h_72
48\1
6-32
18m
3'' M
odul
ar R
oom
MP
S (2
014
IBC
).dw
g05
/12/
2017
- 8:
53am
term
user
--
--
--
--
--
--
--
-07
/25/
16JC
F JC
F IN
IT IS
SUE
NTS UNLESS NOTED
6
6
16-3218I
OLD
SM
AR ,
FL
- (8
13)
855-
2627
35
0 BU
RBAN
K R
D
STR
UCTA
LL B
UIL
DIN
G S
YSTE
MS,
INC.
FRANK L. BENNARDO, P.E.
TABLES 2-7 NOTES:1. WALL LOADS ARE BASED ON ASCE 7-10 "COMPONENTS AND CLADDING" METHOD, ENCLOSED STRUCTURE.2. DEFLECTION LIMIT = L/175.3. VALUES BELOW ALLOWABLE CEILING HEIGHT INTENDED TO BE BUILT ON KNEEWALLS OR OTHER
SUPPORTING STRUCTURES (CERTIFIED BY OTHERS).4. LOADING CRITERIA CONSIDERED IS THE GOVERNING CASE OF THE FOLLOWING SCENARIOS:
4.1. 2PSF ROOF DEAD LOAD & 30 PSF MINIMUM SOLID ROOF LIVE LOAD USED IN TABLES4.2. WALL WIND LOADS PER ASCE 7-10 C&C METHOD
5. ALL "THERMO" POSTS HAVE BEEN CALCULATED WITH A 10% STRENGTH REDUCTION TO ACCOUNT FOR THERMAL BREAK STRENGTH LOSS.Vasd MAY BE CALCULATED WITH THE FOLLOWING CONVERSION: Vasd=Vult*√0.6
ROOF
SPA
OWN
T SPACINGOMETRIC DETAIL*
SPA
POSTORNER
POST
OST=1)
UPON DION AND INSTA
TIONAL CERTIFICATITHER MARKINGS TO THI
POST 2PP
THER WALL
O PREVENT ELECTR
USE OF THIS SPECIFICATIONDAMAGES INCLUDING LEGAL FEE
STRUCTION PRACTICES BEYOND TN.REIN IS BASED ON CONTRACTOBLE IN ANY WAY FOR ERRONEONSTRUCTION. THIS ENGINEOF ANY INACCURATE INFORMAT OF MATERIALS.
R AFFIRMATIONS ARE INTENDED.UMENT ARE NOT PERMITTED AND IN
ALL
TABLE 6:
TABLE 7:GLASS ALLOWABLE PO
TABLE 8:GLASS ALLOW
GLASS ALLOWA
TJ
TJ
TJH
R TO
IDATE
(3X3 INSERT): 90M( )
EIGHT (I-BEAM INSERT): ( )
EIGHT (I-B
EIGHT (I-BE(
Exp 'C', 120MPH, EXP p , ,
OUGH 100 M
'
M
Exp
OUGH 100 M(3X3 INSERT): 90M( )
EIGHT (I-BEAM INSERT): ( )
EIGHT (I-B(
EIGHT (I-BE(
ALL
PO
ABLE 8GLASS ALLOWA
AB
TJ
THER WALL
O PREVENT ELECTR
USE OF THIS SPECIFICATIONDAMAGES INCLUDING LEGAL FEE
STRUCTION PRACTICES BEYOND THAT WHICHNREIN IS BASED ON CONTRACTORBLE IN ANY WAY FOR ERRONEO
ONSTRUCTION. THIS ENGINEOF ANY INACCURATE INFORMATION PRIOR
NRUMENT ARE NOT PERMITTED AND INVALI
TABLGLASS A
UDINGRACTICES
ED ON CONWAY FORN. TH
CCU
O
T SSO
SPA
TC
O=1
UPON DTION AND INSTA
TIONAL CERTIFICATIOTHER MARKINGS TO THI
F
PA
TAIL*