WicoLine Concrete WLC - ITW constructions · 18 LINE WICO Installation using Spit TAPCON® Dome...

6
13 www.itwconstruction.ee LINE WICO WicoLine Concrete WLC Concrete support mount for windows and doors Attach the window mounts to the wall. Attach the push and pull fittings to the window. Place the window on the mounts and attach the push and pull fittings to the wall. The window can be mounted before or after the exterior insulation is securely attached or a new exterior wall is built. Concrete

Transcript of WicoLine Concrete WLC - ITW constructions · 18 LINE WICO Installation using Spit TAPCON® Dome...

Page 1: WicoLine Concrete WLC - ITW constructions · 18 LINE WICO Installation using Spit TAPCON® Dome Min. 60 mm 6 mm drill bit 60 mm TX 30 Tightening max. 10 Nm Pre-drilling with 6 mm

13www.itwconstruction.ee

LINEWICO

WicoLine Concrete WLCConcrete support mount for windows and doors

Attach the window mounts to the wall.

Attach the push and pull fittings to the window. Place the window on the mounts and attach the push and pull fittings to the wall.

The window can be mounted before or after the exterior insulation is securely attached or a new exterior wall is built.

Concrete

Page 2: WicoLine Concrete WLC - ITW constructions · 18 LINE WICO Installation using Spit TAPCON® Dome Min. 60 mm 6 mm drill bit 60 mm TX 30 Tightening max. 10 Nm Pre-drilling with 6 mm

14 www.itwconstruction.ee

LINEWICO

WicoLine Concrete WLCConcrete support mount for windows and doors

Areas of application Benefits— For external attachment of windows and doors in

wall structures

— For use in concrete

— By exterior façade renovation in new construction

— Time-saving installation, only one part

— Flexible building process, since the mounts can be fitted from the inside without the use of scaffolding

— Long durability due to pre-galvanised high-grade steel with 20 μm

— Minimal thermal bridge due to continuous insulation around the window

— Flexible system in different dimensions depending on the thickness of the insulating material

— High wear capacity equal to 80 kg per mount/0.8 kN per mount

— Spit TAPCON® Dome 6.0 × 60

Choice of attachment

Con

cret

e

Concrete WLC mount fitting

Type length

Page 3: WicoLine Concrete WLC - ITW constructions · 18 LINE WICO Installation using Spit TAPCON® Dome Min. 60 mm 6 mm drill bit 60 mm TX 30 Tightening max. 10 Nm Pre-drilling with 6 mm

15www.itwconstruction.ee

LINEWICO

Scale drawing

TypeDimension

L × H × W × t [mm]

DimensionsF

[mm]

Number of holes Ø5

[mm]

Number of holes Ø8.5

[mm]

Weight[g]

Number of units in

cardboard box

Number of cardboard boxes

per palletDB no. ITW no.

WLC 85 85 × 49 × 51 × 2 12 2 1 185 20 21 1869730 210955

WLC 110 110 × 60 × 51 × 2 15 2 1 250 20 21 1869731 210956

WLC 120 120 × 65 × 51 × 2 15 2 1 284 20 21 1869732 210957

WLC 130 130 × 70 × 51 × 2 20 2 1 319 20 21 1869733 210958

WLC 145 145 × 77 × 51 × 2 20 2 1 353 20 21 1869734 210959

WLC 155 155 × 83 × 51 × 2 30 2 1 387 20 21 1869735 210960

WLC 170 170 × 90 × 51 × 2 30 2 1 431 20 21 1869736 210961

WLC 180 180 × 95 × 51 × 2 30 2 1 475 20 21 1869737 210962

WLC 190 190 × 100 × 51 × 2 30 2 1 515 20 21 1869738 210963

WLC 215 215 × 112 × 51 × 2 30 2 1 626 20 21 1869739 210964

WLC 240 240 × 125 × 51 × 2 30 2 1 737 20 21 1869740 210965

WLC 280 280 × 145 × 51 × 2 30 2 1 932 10 21 1869741 210966

WLC 300 300 × 155 × 51 × 2 30 2 1 1042 10 21 1869742 910967

WLC 330 330 × 170 × 51 × 2 30 2 1 1219 10 21 1869743 210968

10

L + 65

L 65

2

14

5

F

H

51

22

.5

13

24

20 Ø8.5

8

Dimensions: Length: 85-330 mm Height: 49-170 mmMaterials: S250GD + Z275MA According to: EN10346Surface treatment: Hot galvanised approx.

20 μmApplication class: 1-2

Specification and product rangeConcrete support mount for windows and doors

Concrete

Page 4: WicoLine Concrete WLC - ITW constructions · 18 LINE WICO Installation using Spit TAPCON® Dome Min. 60 mm 6 mm drill bit 60 mm TX 30 Tightening max. 10 Nm Pre-drilling with 6 mm

16 www.itwconstruction.ee

LINEWICO

Con

cret

e

WicoLine push WLSPush fittings for absorbing horizontal compression forces

WicoLine pull WLTPull mount for absorbing horizontal tensile forces

Min. 2 brackets per standard window. The mounts are installed at a 45-degree angle in opposite direction at top and bottom

Min. 4 mounts per standard window with 2 mounts per side

Max. 90 cm between mounts

Areas of application

BenefitsBenefits

Wall attachmentWall attachment

Attachment to windows or doorsAttachment to windows or doors

Areas of application

See page 25-26 for line drawings and additional information about push and pull mounts.

Paslode screw 5.0 × 35

Spit frame anchor screw FS-H 7.5 × 62

Paslode screw 5.0 × 35

Spit frame anchor screw FS-H 7.5 × 62

— For bracing of windows and doors

— For installation alongside windows

— For bracing of windows and doors

— For installation at top and bottom of windows

— Spit frame anchor screw FS-H 7.5 × 62 — Spit frame anchor screw FS-H 7.5 × 62

— Paslode screw 5.0 × 35 or shorter — Paslode screw 5.0 × 35 or shorter

— Long durability due to pre-galvanised high-grade steel with 20 μm

— High strength due to angle bracket

— Minimal thermal bridge due to continuous insulation around the window

— Flexible system in different dimensions depending on the thickness of the insulating material

— Long durability due to pre-galvanised high-grade steel with 20 μm

— Minimal thermal bridge due to continuous insulation around the window

— Flexible system in different dimensions depending on the thickness of the insulating material

Page 5: WicoLine Concrete WLC - ITW constructions · 18 LINE WICO Installation using Spit TAPCON® Dome Min. 60 mm 6 mm drill bit 60 mm TX 30 Tightening max. 10 Nm Pre-drilling with 6 mm

17www.itwconstruction.ee

LINEWICO

Dimensioning

Minimum insulation thickness

WicoLine Concrete WLC Mount

WicoLine Push WLS Mount

WicoLine Pull WLT Mount

Recommended mounting

105 210955 WLC 85 210980 WLS 170 210970 WLT 232

Spit Tapcon®Dome 6.0 × 60

130 210956 WLC 110 210981 WLS 190 210971 WLT 260

140 210957 WLC 120 210981 WLS 190 210971 WLT 260

150 210958 WLC 130 210982 WLS 200 210972 WLT 275

165 210959 WLC 145 210983 WLS 215 210973 WLT 296

175 210960 WLC 155 210984 WLS 225 210974 WLT 310

190 210961 WLC 170 210985 WLS 240 210975 WLT 331

200 210962 WLC 180 210986 WLS 250 210976 WLT 345

210 210963 WLC 190 210986 WLS 250 210976 WLT 345

235 210964 WLC 215 210987 WLS 290 210977 WLT 400

260 210965 WLC 240 210987 WLS 290 210977 WLT 400

300 210966 WLC 280 210988 WLS 350 210978 WLT 487

320 210967 WLC 300 210989 WLS 370 210978 WLT 487

350 210968 WLC 330 210989 WLS 370 210978 WLT 487

There must be at least 20 mm insulation measured from the tip of the mount to the outer insulation due to corrosion and thermal bridge.

WLC is used, where the inner wall is at least concrete C20.

The maximum load on WicoLine Concrete Mount is approximately 80 kg or 0.8 kN.

Recommended dimensions

Concrete

Concrete WLC mount fitting

Min. 20 mm

Page 6: WicoLine Concrete WLC - ITW constructions · 18 LINE WICO Installation using Spit TAPCON® Dome Min. 60 mm 6 mm drill bit 60 mm TX 30 Tightening max. 10 Nm Pre-drilling with 6 mm

18 www.itwconstruction.ee

LINEWICO

Installation using Spit TAPCON® Dome

Min. 60 mm6 mm drill bit

60 mmTX 30

Tightening max. 10 Nm

Pre-drilling with 6 mm drill bit.

Tighten with TX 30 to a maximum of 10 Nm.

Blow 3 times to remove the last particles.

It is possible to use any other Spit TAPCON® concrete screws with a diameter of 6.0 mm and length of at least 60 mm.

DB no. ITW no. DimensionsQuantity

per package

1850592 058784 6.0 × 60/25 - 3 mm 100

Installation of WLC

Con

cret

e

ITW Construction Products OÜ Türi 10D • 11314 Tallinn • Estonia T +372 651 2462 • F +372 651 2463 www.itwconstruction.ee