FLOWCONTROL FLOW RATESEmitter Flow

Part NumberOutlet

SpacingEmitter Flow Rate Q-100 Emitter

ExponentFiltration

Requirementgph lph gpm/100 ft lph/1 meterin cm mesh (micron)@ 10 psi @ 0.7 bar @ 10 psi @ 0.7 bar

0.13 gph emitterEAFCXxx1222 12 30 0.13 0.51 0.22 1.66

0.3 150 (98)EAFCXxx2411 24 60 0.13 0.51 0.11 0.83

0.20 gph emitterEAFCXxx0667 6 15 0.20 0.76 0.67 4.99

0.3 150 (98)

EAFCXxx0850 8 20 0.20 0.76 0.50 3.74

EAFCXxx1234 12 30 0.20 0.76 0.34 2.50

EAFCXxx1625 16 40 0.20 0.76 0.25 1.87

EAFCXxx1822 18 45 0.20 0.76 0.22 1.67

EAFCXxx2417 24 60 0.20 0.76 0.17 1.25

0.27 gph emitterEAFCXxx0690 6 15 0.27 1.01 0.90 6.66

0.3 150 (98)

EAFCXxx0867 8 20 0.27 1.01 0.67 4.99

EAFCXxx1245 12 30 0.27 1.01 0.45 3.33

EAFCXxx1634 16 40 0.27 1.01 0.34 2.50

EAFCXxx1830 18 45 0.27 1.01 0.30 2.22

EAFCXxx2422 24 60 0.27 1.01 0.22 1.67

Emitter Flow vs PressureEmitter Flow vs Pressure

Flow

Rat

e (g

ph)

Pressure (psi)

0.00

0.05

0.10

0.15

0.20

0.25

0.30

0.35

0.40

4 6 8 10 12 14 16 18 20 22 24

0.20 gph @ 10 psi

0.27 gph @ 10 psi

0.13 gph @ 10 psi

FLOWCONTROL™ FLOWCONTROL™

FLOWCONTROL WALL THICKNESSDiameter Wall

ThicknessOperating Pressure Reel Length Reel Weight

psi barft meters lbs kg

min max† min max†

5/8” (16mm)0.635”

6 mil 4 16 0.3 1.1 10,000 3,048 64 29

8 mil 4 16 0.3 1.1 7,500 2,286 66 30

10 mil 4 25 0.3 1.7 6,000 1,829 63 29

12 mil 4 25 0.3 1.7 5,100 1,554 63 29

15 mil 4 25 0.3 1.7 4,000 1,219 63 29

7/8” (22mm)0.880”

8 mil 4 15 0.3 1.0 6,000 1,829 72 33

10 mil 4 20 0.3 1.4 4,400 1,341 71 32

12 mil 4 20 0.3 1.4 4,000 1,219 72 33

15 mil 4 22 0.3 1.5 3,000 914 66 30

1 3/8” (35mm)1.380”

15 mil 4 18 0.3 1.3 2,700 823 87 39

Page 5: FLOWCONTROL - Toro

0 1000 2000 3000 4000 5000 6000

1 ⅜

0.11

0.17

0.22

0.25

0.30

0.34

0.45

0.5

0.67

0.90

Note: Information contained in Length of Run Charts represents single lateral uniformities only. While operating or flushing, pressures within laterals are not to exceed maximum pressure specification. Charts are for reference only – a professional irrigation system designer should be used when designing an irrigation system. For more irrigation design information, refer to AquaFlow at aquaflow.toro.com.