INSIDE Fluid Transfer Division Floating suctions – C0001-C0013, C0015, C0093 C0001-C0013, C0015, C0093 EMCO WHEATON floating suctions Design: various designs, depending on the tank dimensions and inlet position sizes: 2“ to 24“ the product is always is transferred within a defined distance under the liquid level contamination dirt /sedi- ments /solid particles and heavy fluids remain separa- ted on the tank bottom constant product quality independent from liquid level long lifetime and low wear characteristics due to splitt flange ball bearing swivel joints easy installation via internal swivel joint flanging high pressure rating for both internal and external (pres- sure variations) vortex prevention through optimal inlet design pressure-proof floats Floating suctions compared with per- manently fixed nozzles have the follo- wing advantages:

Transcript of Floating suctions – C0001-C0013, C0015, C0093 ... - … · EMCO WHEATON floating suctions...

INSIDE

Fluid Transfer Division

Floating suctions – C0001-C0013, C0015, C0093

C00

01-C

0013

, C00

15, C

0093

EMCO WHEATON floating suctions

Design:

• variousdesigns,dependingonthetankdimensionsandinletposition

• sizes:2“to24“

• theproductisalwaysistransferredwithinadefineddistanceundertheliquidlevel

• contaminationdirt /sedi-ments/solidparticlesandheavyfluidsremainsepara-tedonthetankbottom

• constantproductqualityindependentfromliquidlevel

• longlifetimeandlowwearcharacteristicsduetosplittflangeballbearingswiveljoints

• easyinstallationviainternalswiveljointflanging

• highpressureratingforbothinternalandexternal(pres-surevariations)

• vortexpreventionthroughoptimalinletdesign

• pressure-prooffloats

Floating suctions compared with per-manently fixed nozzles have the follo-wing advantages:

EMCOWHEATONUSAINC9111JackrabbitRoad·Houston,Texas77095·USA

Phone+1281856-1300·Fax+1281856-1325www.emcowheaton.com·[email protected]

Whilst the content of this leaflet has been edited with the greatest care, we are not liable for any errors and/or omissions. Subject to change without notice.

ISO9001

Materials and technical data

C00

01-C

0013

,C00

15,C

0093

US

A0

7/06

Dimensions and technical data

Floating suctions – C0001-C0013, C0015, C0093

EMCO WHEATON floating suction for any container/tankFor use in semi-buried tankage with lateral outlet on the centre-line

C0001 right hand design C0002 left hand design C0003 centre design

single arm

For use in buried tankage with the outlet through the manhole

C0004 connection at Pos. I C0005 connection at Pos. II C0006 connection at in Pos. III C0007 connection at Pos. IV C0008 connection at Pos. V

single arm

For use in above ground tankage with lateral outlet near the bottom

C0009 right hand design C0010 left hand design C0011 centre design at Pos. V

single arm

For use in vertical storage tanks with lateral outlet near the bottom

C0012 left hand design

C0013 left hand design

double arm

triple arm

The tank diameter must be bigger than the maximum fluid level.

At fluid levels bigger than the tank diameter double or triple arm floating suctions may be required depending on the relation between ∅ and height.

For articulated drainage units with floating ceiling/floating roof

C0015 left hand design „hanging“two-pieces

The loads resulting from the weight of the floating suction must be absorbed by the floating ceiling/roof.

For articulated drainage units with floating ceiling/floating roof

C0093 right hand design with rollsingle arm

Tank roof design must absorb the force of floating suction.

Aluminum, Steel or Stainless steel

Buna, Viton or PTFE (other seals available)

pressureless

+14 °F up to +125 °F

materials of product carrying parts

materials of seals

design pressure

design temperatureAlternativeconfigurationsonrequest.

• Theexactsizeisdependantontherequiredsuctionspeed.Theflowvelocityshouldnotexceed3ft/s.

• Designandlength(s)offloatingsuctionwillbedeterminedbykindoftankconfigurationandallrelevantdimensions.

• Optimisingthedesignofthefloatingsuctionpleasefillinour„datasheetfloatingsuctions“.

• Iftherearenospecialinstruc-tionsthefloatingsuctionwillbedesignedthatallpartscanbeinstalledthroughamanholesize24inch.Thefloatingsuctionwillbedeliveredinparts.