FEDERAL ELECTRICITY AND WATER AUTHORITY
UNITED ARAB EMIRATES
INTRODUCTION
FEDERAL ELECTRICITY AND WATER AUTHORITY (FEWA) IS ONE OF THE
UTILITY IN THE UNITED ARAB EMIRATES RESPONSIBLE FOR THE SUPPLY AND
DISTRIBUTION OF ELECTRICITY AND WATER IN THE NORTHERN EMIRATES.
THE AREAS OF NORTHERN EMIRATES COVERED BY FEWA ARE THE
FOLLOWING
AJMAN (WEST)
RAS AL KHAIMAH (NORTH)
UM AL QUWAIN (WEST)
FUJAIRAH (EAST)
DHAID (CENTRAL)
AMI PILOT PROJECT INITIATIVE BY FEWA
THE IDEA OF A IMPLEMENTING AN AUTOMATIC METER READING (AMR) PILOT PROJECT WAS INITIATED IN THE YEAR 2007 BY THE MANAGEMENT OF FEWA.
FEWA ATTENDED VARIOUS PRESENTATIONS, SEMINARS AND VISITED INSTALLATIONS TO UNDERSTAND THE TECHNLOGY THAT WAS AVAILABLE.
THE PILOT PROJECT IMPLEMENTATION WAS DELAYED DUE TO ONE
MAIN REASON …..….
“THERE WAS NO CLEAR AND SATISFACTORY INTEROPERABLE PROTOCOL THAT
WAS WELL DEFINED THAT COULD PROVIDE US WITH AN OPEN SYSTEM”
TODAY THE TECHNOLOGY HAS ADVANCED AND THERE IS A CLEAR DIRECTION
TOWARDS INTEROPERABILITY AND OPEN SYSTEMS.
FEWA BY WAY OF THE PILOT PROJECT IMPLEMENTATION WILL BE WELL
PLACED TO TAKE INTO CONSIDERATION FUTURE EVOVLING TECHNOLOGIES
IN THIS FIELD DURING THE FINAL ROLL OUTS.
BRIEF DETAILS OF AMI PILOT PROJECT
RESIDENTIAL VILLAS AND
SMALL COMMERCIAL
ESTABLISHMENTS
BUILDINGS FOR
OFFICES AND
RESIDENTIAL
APARTMETNS
INDUSTRIAL AREA
Nuaimiya Area - Ajman
ENTERPRISE
SAP SOLUTIONS
AMI MDM S/W
MDUS
HEAD ENDS
MDUS
PI INTEGRATOR
AMI SOFTWARE
AND SYSTEM
DATA
CONCENTRATORS
ELECTRICITY METERS
(RESIDENTIAL + C & I)
WATER METERS
SAPCurrently being
implemented
To be awarded to
any one
manufacturer
To be awarded to
two
manufacturers
BPLC
COMMUNICATIONS
To be awarded to
three
manufacturers
To be awarded to
three
manufacturers
To be awarded to
two manufacturers
APPROVALS AND
PREQUALIFICATION PROCESS
Consideration for
additional MDM
suppliers
To pre-qualify
three
manufacturers
To pre-qualify four
manufacturers
To pre-qualify six
manufacturers
To pre qualify six
manufacturers
START END
Details and Objectives
FEWA
ENTERPRISE
BACKEND
SYSTEM - SAP
A B C
A B C
A B C
AMI MDM S/W
MDUS
HEAD ENDS
MDUS
PI INTEGRATOR
AMI SOFTWARE
AND SYSTEM
DATA
CONCENTRATORS
ELECTRICITY
METERS
WATER METERS
INTEROPERABLE
PROTOCOLS
MDUS PROTOCOL
DLMS/COSEM
PROTOCOL
DLMS/COSEM
PROTOCOL
M-BUS
PROTOCOL
MV BPLC / WAN
LV PLC
WIRED / WIRELESS
MBUS
INTEROPERABILITY – Open Solutions
OBJECTIVES - OPEN SYSTEM
PROTOCOL
M-BUS PROTOCOL
DLMS / COSEM
DLMS / COSEM (TCP/IP)
AMI MDM SYSTEM
AMI MDM SYSTEM
MDUS
ENTERPRISE SAP SOLUTION
WATER METERS
ELECTRICITY METERS
DATA CONCENTRATORS
BROAD BAND OVER POWER LINE CARRIER COMMUNICATION FOR AMI
X X X X
Main WAN Intranet on Fiber, Pilot cable or Radio
X
RING MAIN UNIT
X X
BPLC modem
Ethernet port
DISTRIBUTION
TRANSFORMER
Ethernet
port
11 KV
Ethernet port
DC DC DC
LV
PLC
LV
PLC
LV
PLC
MV
BPLC
BROAD BAND OVER POWER LINE CARRIER COMMUNICATION OTHER APPLICATIONS
X X X X
Main WAN Intranet on Fiber, Pilot cable or Radio
X
RING MAIN UNIT
BPLC
modem
Ethernet port
DISTRIBUTION
TRANSFORMER
REMOTE
TERMINAL
UNIT
INDICATIONS AND ALARMS
MEASURMENTS
CONTROLS
ELECTRICAL
LINEAR
ACTUATOR
TRANSFORMER MONITORING
FORESEEN CONSTRAINTS
Lv P
ow
er
Lin
e C
arr
ier
M-Bus DATA CONCENTRATOR
FOR WATER METERS
M-Bus wired / wireless
PLC DATA
CONCENTRATOR
REACTIVE POWER
COMPENSATORS ON LV
NETWORK
LINE NOISE
CONSIDERATIONS OF DATA
THROUGHPUT
IDIS
Why is it considered by FEWA in Pilot Project ??
The IDIS group defines DLMS/COSEM compliant interoperability parameters
between
•Water meters and Electricity meters (Mbus protocol)
•Electricity meters and Data Concentrators (DLMS/COSEM Protocol)
•Data Concentrators and AMI MDM (DLMS/COSEM Protocol)
Extensive tests are already conducted by ERDF in France for interoperability
Using the IDIS interoperable standards for the FEWA pilot
project will save time and efforts in the open systems testing.
FEWA do not intend to have a specialized team or hire a third
party consultant for interoperable tests between various
vendors.
Conclusion