Features Package Arrangement - Tuba-Turbine

14
CENTAUR 40 Gas Turbine Generator Set Package Arrangement Gas Turbine Centaur ® 40 Industrial, Single-Shaft Axial Compressor – 11 Stages Annular Combustion Chamber 10 Fuel Injectors Coatings – Compressor: Inorganic Aluminum Turbine and Nozzle Blades: Precious Metal Diffusion Aluminide Proximity Probe Vibration Transducers Main Reduction Drive Epicyclic 1800 or 1500 rpm – Acceleration Vibration Transducers Generator Salient Pole, 3 Phase, 6 Wire, Wye Connected, Synchronous with Brushless Exciter Open Drip-Proof Construction Sleeve Bearings Velocity Vibration Transducers Solid-State Voltage Regulation with Permanent Magnet Generator NEMA Class F Insulation with F Rise Continuous Duty Rating Package Steel Base Frame with Drip Pans Direct-Drive AC Start System Natural Gas Fuel System Features Industrial Gas Turbine Package Compact, Integrated Package Providing Ease of Installation Factory Tested Dry, Low Emission (SoLoNOx™) Combustion Available Control System – Microprocessor-Based PLC – Generator Control Vibration and Temperature Monitoring – Auto Synchronizing Integrated Lube Oil System Turbine-Driven Lube Pump AC Pre/Post Lube Pump Backup Lube Pump Air/Oil Cooler Integral Lube Oil Tank Lube Oil Tank Heater Lube Oil Filter Documentation – Drawings Quality Control Data Book Inspection and Test Plan – Test Reports O&M Manuals Factory Testing of Turbine and Package Optional Equipment/Services Generator Options: WPII, TEWAC Standby Duty Rating Standard Voltages: 3300, 6600, 11,000 50 Hz; 4160, 6900, 12,470, 13,800 60 Hz Fuel Systems – Liquid – Dual (Gas/Liquid) SoLoNOx, Dry, Low Emission Alternate Fuels (such as naphtha, propane, low Btu) Lube Oil System Water/Oil Lube Cooler – Electrostatic Demister Duplex Lube Oil Filters Control System Remote Display/Control Terminal Heat Recovery Application Interface Serial Link Supervisory Interface KW Control KVAR/Power Factor Control Turbine Performance Map – Historical Displays – Printer/Logger Predictive Emissions Monitoring Field Programming Terminal Accessory Equipment – 24-VDC Battery/Charger System – Turbine Cleaning System: On-Crank and On-line Package Lifting Kit Weatherproof Acoustic Enclosure Ancillary Equipment: Various Air Inlet and Exhaust Systems Inlet and Exhaust Silencers Self-Cleaning or Prefilter/Barrier Air Inlet Filter Inlet Evaporative Cooler Inlet Chiller Coils Ancillary Support Frame Onskid Microprocessor-Control with Auto Sync Capability Multiple Fuel Capability Industrial/Utility Grade

Transcript of Features Package Arrangement - Tuba-Turbine

CENTAUR 40Gas Turbine Generator Set

Package Arrangement

Gas Turbine

• Centaur ® 40 Industrial, Single-Shaft

• Axial Compressor – 11 Stages

• Annular Combustion Chamber

– 10 Fuel Injectors

• Coatings

– Compressor: Inorganic Aluminum

– Turbine and Nozzle Blades:

Precious Metal Diffusion Aluminide

• Proximity Probe Vibration Transducers

Main Reduction Drive

• Epicyclic

– 1800 or 1500 rpm

– Acceleration Vibration Transducers

Generator

• Salient Pole, 3 Phase, 6 Wire,Wye Connected, Synchronous withBrushless Exciter

• Open Drip-Proof Construction

• Sleeve Bearings

• Velocity Vibration Transducers

• Solid-State Voltage Regulation withPermanent Magnet Generator

• NEMA Class F Insulation with F Rise

• Continuous Duty Rating

Package

• Steel Base Frame with Drip Pans

• Direct-Drive AC Start System

• Natural Gas Fuel System

Features

• Industrial Gas Turbine Package

• Compact, Integrated PackageProviding Ease of Installation

• Factory Tested

• Dry, Low Emission (SoLoNOx™)Combustion Available

• Control System

– Microprocessor-Based PLC

– Generator Control

– Vibration and Temperature Monitoring

– Auto Synchronizing

• Integrated Lube Oil System

– Turbine-Driven Lube Pump

– AC Pre/Post Lube Pump

– Backup Lube Pump

– Air/Oil Cooler

– Integral Lube Oil Tank

– Lube Oil Tank Heater

– Lube Oil Filter

• Documentation

– Drawings

– Quality Control Data Book

– Inspection and Test Plan

– Test Reports

– O&M Manuals

• Factory Testing of Turbine and Package

Optional Equipment/Services

• Generator Options:

– WPII, TEWAC

– Standby Duty Rating

– Standard Voltages:3300, 6600, 11,000 50 Hz;4160, 6900, 12,470, 13,800 60 Hz

• Fuel Systems

– Liquid

– Dual (Gas/Liquid)

– SoLoNOx, Dry, Low Emission

– Alternate Fuels (such as naphtha,propane, low Btu)

• Lube Oil System

– Water/Oil Lube Cooler

– Electrostatic Demister

– Duplex Lube Oil Filters

• Control System

– Remote Display/Control Terminal

– Heat Recovery Application Interface

– Serial Link Supervisory Interface

– KW Control

– KVAR/Power Factor Control

– Turbine Performance Map

– Historical Displays

– Printer/Logger

– Predictive Emissions Monitoring

– Field Programming Terminal

• Accessory Equipment

– 24-VDC Battery/Charger System

– Turbine Cleaning System: On-Crankand On-line

– Package Lifting Kit

• Weatherproof Acoustic Enclosure

• Ancillary Equipment: Various Air Inletand Exhaust Systems

– Inlet and Exhaust Silencers

– Self-Cleaning or Prefilter/BarrierAir Inlet Filter

– Inlet Evaporative Cooler

– Inlet Chiller Coils

– Ancillary Support Frame

• Onskid Microprocessor-Controlwith Auto Sync Capability

• Multiple Fuel Capability

Industrial/Utility Grade

Solar Turbines IncorporatedP.O. Box 85376San Diego, CA 92186-5376

Caterpillar is a trademark of Caterpillar Inc.Solar, Centaur and SoLoNOx are trademarks of Solar Turbines Incorporated.Specifications subject to change without notice. Printed in U.S.A.©1998 Solar Turbines Incorporated. All rights reserved.DS40IPG/1198/5M

FOR MORE INFORMATION

Telephone: (+1) 619-544-5352Telefax: (+1) 619-544-2633Telex: 695045Internet: www.solarturbines.com

CENTAUR 40Gas Turbine Generator Set

Available PerformanceNominal Performance*

Output Power, kWeISO: 15°C (59°F), sea level 3515

Heat Rate, kJ/kWe-hr 12 912(Btu/kWe-hr) (12,240)

Exhaust Flow, kg/hr 67 004

(lb/hr) (147,718)

Exhaust Temperature, °C 437(°F) (819)

* No inlet or exhaust lossesRelative humidity 60%Natural gas fuel withLHV = 31.5 to 43.3 MJ/nm3

(800 to 1100 Btu/scf)

Forward End

• Turbine Control Box

Left Side

• Lube Oil: Drain, Vent, Cooler

• Generator Control Box, Power

• Generator Drip Pan Drain

• AC Power

– Lube Tank Heater

– Pre/Post Lube Pump

– Backup Lube Pump

Right Side

• AC Power - Start Motor

• Generator Monitor Box

Aft End

• Fuel Inlet

• Turbine Cleaning

• Fuel Filter, Combustor andExhaust Collector Drains

• Auxiliary Air (optional) for:

– Liquid Fuel Atomizing

– Self-Cleaning Filter

• AC Power

– Liquid Fuel Pump (optional)

• Package Ground

Typical Service Connections

Length: 9754 mm (32’ 0”)

Width: 2438 mm (8’ 0”)

Height: 2591 mm (8’ 6”)

Approx.

Weight: 26 015 kg (57,350 lb)

DS40IPG-003M

Aft EndLeft SideForward End

250 (482)

OU

TP

UT

PO

WE

R A

T G

EN

ER

AT

OR

TE

RM

INA

L, M

We

6.0

-30 (-22)

INLET AIR TEMPERATURE, °C (°F)

5.5

5.0

4.5

4.0

3.5

3.0

2.5

2.0

1.5

1.0

0.5

10 (50)

18 (61)

16 (55)

14 (48)

12 (41)

10 (34)

8 (27)

300 (572)350 (662)

400 (752)

450 (842)

500 (932)

76 (

168)

74 (

163)

72 (

159)

70 (

154)

68 (

150)

64 (

141)

62 (

137)

Fuel Flow, MW (MM Btu/hr)

Exhaust Temperature, °C (°F) Exh

au

st F

low

, T

ho

usa

nd

s kg

/hr

(lb

/hr)

50 (122)30 (86)

66 (

146)

Full Load Output

-10 (14)

DS40IPG-002M

CENTAUR 50Gas Turbine Generator Set

Package Arrangement

Gas Turbine

• Centaur ® 50 Industrial, Single-Shaft

• Axial Compressor – 11 Stages

• Annular Combustion Chamber

– 12 Fuel Injectors

• Coatings

– Compressor: Inorganic Aluminum

– Turbine and Nozzle Blades:

Precious Metal Diffusion Aluminide

• Proximity Probe Vibration Transducers

Main Reduction Drive

• Epicyclic

– 1800 or 1500 rpm

– Acceleration Vibration Transducers

Generator

• Salient Pole, 3 Phase, 6 Wire,Wye Connected, Synchronous withBrushless Exciter

• Open Drip-Proof Construction

• Sleeve Bearings

• Velocity Vibration Transducers

• Solid-State Voltage Regulation withPermanent Magnet Generator

• NEMA Class F Insulation with F Rise

• Continuous Duty Rating

Package

• Steel Base Frame with Drip Pans

• Direct-Drive AC Start System

• Natural Gas Fuel System

Features

• Industrial Gas Turbine Package

• Compact, Integrated PackageProviding Ease of Installation

• Factory Tested

• Dry, Low Emission (SoLoNOx™)Combustion Available

• Control System

– Microprocessor-Based PLC

– Generator Control

– Vibration and Temperature Monitoring

– Auto Synchronizing

• Integrated Lube Oil System

– Turbine-Driven Lube Pump

– AC Pre/Post Lube Pump

– Backup Lube Pump

– Air/Oil Cooler

– Integral Lube Oil Tank

– Lube Oil Tank Heater

– Lube Oil Filter

• Documentation

– Drawings

– Quality Control Data Book

– Inspection and Test Plan

– Test Reports

– O&M Manuals

• Factory Testing of Turbine and Package

Optional Equipment/Services

• Generator Options:

– WPII, TEWAC

– Standby Duty Rating

– Standard Voltages:3300, 6600, 11,000 50 Hz;4160, 6900, 12,470, 13,800 60 Hz

• Fuel Systems

– Liquid

– Dual (Gas/Liquid)

– SoLoNOx, Dry, Low Emission

– Alternate Fuels (such as naphtha,propane, low Btu)

• Lube Oil System

– Water/Oil Lube Cooler

– Electrostatic Demister

– Duplex Lube Oil Filters

• Control System

– Remote Display/Control Terminal

– Heat Recovery Application Interface

– Serial Link Supervisory Interface

– KW Control

– KVAR/Power Factor Control

– Turbine Performance Map

– Historical Displays

– Printer/Logger

– Predictive Emissions Monitoring

– Field Programming Terminal

• Accessory Equipment

– 24-VDC Battery/Charger System

– Turbine Cleaning System: On-Crankand On-line

– Package Lifting Kit

• Weatherproof Acoustic Enclosure

• Ancillary Equipment: Various Air Inletand Exhaust Systems

– Inlet and Exhaust Silencers

– Self-Cleaning or Prefilter/BarrierAir Inlet Filter

– Inlet Evaporative Cooler

– Inlet Chiller Coils

– Ancillary Support Frame

• Onskid Microprocessor-Controlwith Auto Sync Capability

• Multiple Fuel Capability

Industrial/Utility Grade

Solar Turbines IncorporatedP.O. Box 85376San Diego, CA 92186-5376

Caterpillar is a trademark of Caterpillar Inc.Solar, Centaur and SoLoNOx are trademarks of Solar Turbines Incorporated.Specifications subject to change without notice. Printed in U.S.A.©1998 Solar Turbines Incorporated. All rights reserved.DS50IPG/1198/5M

FOR MORE INFORMATION

Telephone: (+1) 619-544-5352Telefax: (+1) 619-544-2633Telex: 695045Internet: www.solarturbines.com

CENTAUR 50Gas Turbine Generator Set

Available PerformanceNominal Performance*

Output Power, kWeISO: 15°C (59°F), sea level 4600

Heat Rate, kJ/kWe-hr 12 269(Btu/kWe-hr) (11,628)

Exhaust Flow, kg/hr 68 680

(lb/hr) (151,410)

Exhaust Temperature, °C 509(°F) (949)

* No inlet or exhaust lossesRelative humidity 60%Natural gas fuel withLHV = 31.5 to 43.3 MJ/nm3

(800 to 1100 Btu/scf)

Forward End

• Turbine Control Box

Left Side

• Lube Oil: Drain, Vent, Cooler

• Generator Control Box, Power

• Generator Drip Pan Drain

• AC Power

– Lube Tank Heater

– Pre/Post Lube Pump

– Backup Lube Pump

Right Side

• AC Power - Start Motor

• Generator Monitor Box

Aft End

• Fuel Inlet

• Turbine Cleaning

• Fuel Filter, Combustor andExhaust Collector Drains

• Auxiliary Air (optional) for:

– Liquid Fuel Atomizing

– Self-Cleaning Filter

• AC Power

– Liquid Fuel Pump (optional)

• Package Ground

Typical Service Connections

Length: 9754 mm (32’ 0”)

Width: 2438 mm (8’ 0”)

Height: 2591 mm (8’ 6”)

Approx.

Weight: 27 430 kg (60,470 lb)

DS50IPG-003M

Aft EndLeft SideForward End

INLET AIR TEMPERATURE, °C (°F)DS50IPG-002M

-40 (-40) -20 (-4) 0 (32) 20 (68) 40 (104)

OU

TP

UT

PO

WE

R A

T G

EN

ER

AT

OR

TE

RM

INA

L,

MW

E

6.5

6.0

5.5

4.5

4.0

3.5

3.0

2.5

2.0

1.5

1.0

5.0

20 (68)

18 (61)

550 (1022)

Full Load Output450 (842)

400 (752)

350 (662)

250 (482)

200 (392)

16 (55)

14 (48)

12 (41)

300 (572)10 (34)

8 (27)

Fuel Flow, MW (MM Btu/hr)Exhaust Temperature, °C (°F)

500 (932)

78

(1

72

)

74

(1

63

)

70

(1

54

) 66

(1

46

)

62

(1

37

)

58 (

129)

Exh

aust

Flo

w, T

housa

nds

kg/h

r (lb/h

r)

General SpecificationsMars® 100 Gas Turbine

• Industrial, Two-Shaft

• Axial Compressor– 15-Stage– Variable Inlet Guide Vanes– Compression Ratio: 17.4:1– Inlet Airflow:

41.3 kg/sec (91.0 lb/sec)– Max. Speed: 11,168 rpm– Vertically Split Case

• Combustion Chamber– Annular-Type– Conventional or Lean-Premixed,

Dry, Low Emission (SoLoNOx ™)– 21 Fuel Injectors (Conventional)– 14 Fuel Injectors (SoLoNOx )– Torch Ignitor System

• Gas Producer Turbine– 2-Stage, Reaction– Max. Speed: 11,168 rpm

• Power Turbine– 2-Stage, Reaction– Max. Speed: 9500 rpm

• Bearings– Journal: Tilting-Pad– Thrust, Active: Tilting-Pad– Thrust, Inactive:

Fixed Tapered Land

• Coatings– Compressor Stators and Drum:

Inorganic Aluminum– Turbine and Nozzle Blades:

Precious Metal Diffusion Aluminide

• Vibration Transducer Type– Proximity Probes

Key Package Features

• Driver Skid with Drip Pans

• Driven Equipment Skid– Compressor– Compressor Auxiliary Systems

• 316L Stainless Steel Piping <4"

• Compression-Type Tube Fittings

• Gauge Panel Options– Fluid Gauges– Digital Display

• Electrical System Options– NEC, Class I, Group D, Div 1 or 2– CENELEC, Zone 1

• Turbotronic™ MicroprocessorControl System– Freestanding Control Console– Color Video Display– Vibration Monitoring

• Control Options– 24-VDC Control Battery/

Charger System– 120-VDC Accessory Battery/

Charger System– Gas Turbine and Package

Temperature Monitoring– Serial Link Supervisory Interface– Turbine Performance Map– Compressor Performance Map– Historical Displays– Printer/Logger– Predictive Emissions Monitoring– Process Controls– Compressor Anti-Surge Control– Field Programming

• Start Systems– Pneumatic– Direct Drive AC

• Fuel Systems– Natural Gas– Dual (Gas/Liquid)

• Integrated Lube Oil System– Turbine-Driven Accessories– AC Motor-Driven Accessories

• Oil System Options– Oil Cooler– Oil Heater– Tank Vent Separator– Flame Trap

• Axial Compressor Cleaning Systems– On-Crank– On-Crank/On-Line– Portable Cleaning Tank

• Gearbox (if applicable)– Speed Increaser– Speed Decreaser

• Air Inlet and ExhaustSystem Options

• Enclosure and Associated Options

• Factory Testing of Turbineand Package

• Documentation– Drawings– Quality Control Data Book– Inspection and Test Plan– Test Reports– Operation and Maintenance

Manuals

MARS 100Gas Turbine Compressor Set

Solar Turbines IncorporatedP.O. Box 85376San Diego, CA 92186-5376 U.S.A.

Available PowerPerformanceNo Inlet/Exhaust Losses,Relative Humidity 60%,Natural Gas Fuel withLHV = 31.5 to 43.3 MJ/nm3

(800 to 1100 Btu/scf)Optimum Power Turbine SpeedAC-Driven AccessoriesEngine Efficiency: 34.0%

Nominal Rating – ISOAt 15°C (59°F), Sea Level

Output Power11 185 kW (15,000 hp)

Heat Rate10 545 kJ/kW-hr (7490 Btu/hp-hr)

Exhaust Flow150 700 kg/hr (331,500 lb/hr)

Exhaust Temp486°C (906°F)

15°C (59°F) Turbine Rating Match.Other Turbine Rating Match PointsAre Available.

Package Dimensions

Caterpillar is a trademark of Caterpillar Inc.Solar, Mars, SoLoNOx , and Turbotronic are trademarks of Solar Turbines Incorporated.Specifications subject to change without notice. Printed in U.S.A.© 1999 Solar Turbines Incorporated. All rights reserved.DS100CS/699/2M

FOR MORE INFORMATIONTelephone: (+1) 619-544-5352Telefax: (+1) 619-544-2633Internet: www.solarturbines.com

MARS 100Gas Turbine Compressor Set

TURBINEAIR INLET

TURBINEEXHAUST

8611 mm(29' 6")

3563 m

m(1

1' 8

-1/4

")

DS100CS-003M

5512 mm (18' 1")

Typical Weight: 73 331 kg (161,616 lb) Width: 2794 mm (9' 2")

40 (136)

35 (119)

30 (102)

25 (85)

20 (68)

15 (51)

10 (34)

170

(375

)

160 (353)

150 (331)

140 (309)

130 (287)

120 (265)

110 (243)

100 (220)

90 (198)

80 (176)

70 (154)

525 (977)475 (887)

425 (797)

375 (707)

325 (617)

275 (527)

Full Load Output

Fuel Flow, MW (MM Btu/hr)

Exhaust Flow, Thousands kg/hr (lb/hr)7000

(9387)

9000(12,069)

5000(6705)

3000(4023)

1000(1341)

(14,751)

13 000(17,433)

OU

TP

UT

PO

WE

R P

AR

AM

ET

ER

, kW

(hp)

INLET AIR TEMPERATURE, ˚C (˚F) DS100CS-002M

-40 -30 -20 -10 0 10 20 30 40 50(-40) (-22) (-4) (14) (32) (50) (68) (86) (104)

15 000(20,115)

Exhaust T

emperature, ˚C

(˚F)

(122)

11 000

SATURN 20Gas Turbine Generator Set

Package Arrangement

Gas Turbine

• Saturn® 20 Industrial, Single-Shaft

• Axial Compressor – 8 Stages

• Annular Combustion Chamber

– 12 Fuel Injectors

• Coatings

– Compressor: Inorganic Aluminum

– Turbine and Nozzle Blades:

Precious Metal Diffusion Aluminide

• Velocity Vibration Transducers

Main Reduction Drive

• Epicyclic

– 1800 or 1500 rpm

– Acceleration Vibration Transducers

Generator

• Salient Pole, 3 Phase, 6 Wire,Wye Connected, Synchronous withBrushless Exciter

• Open Drip-Proof Construction

• Sleeve Bearings

• Velocity Vibration Transducers

• Solid-State Voltage Regulation withPermanent Magnet Generator

• NEMA Class H Insulation with H Rise

• Continuous Duty Rating

Features

• Industrial Gas Turbine Package

• Compact, Integrated PackageProviding Ease of Installation

• Factory Tested

• Multiple Fuel Capability

Package

• Steel Base Frame with Drip Pans

• Direct-Drive AC or PneumaticStart System

• Natural Gas Fuel System

• Control System

– Microprocessor-Based PLC

– Generator Control

– Vibration and Temperature Monitoring

– Auto Synchronizing

• Integrated Lube Oil System

– Turbine-Driven Lube Pump

– AC Pre/Post Lube Pump

– Air/Oil Cooler

– Integral Lube Oil Tank

– Lube Oil Filter

• Documentation

– Drawings

– Quality Control Data Book

– Inspection and Test Plan

– Test Reports

– O&M Manuals

• Factory Testing of Turbine and Package

• Weatherproof Acoustic Enclosure

Optional Equipment/Services

• Generator Options:

– Standby Duty Rating

– Standard Voltages: 380, 415, 3300 50 Hz;240, 480 2400, 4160 60 Hz

• Fuel Systems

– Liquid

– Dual (Gas/Liquid)

– Water Injection for NOx Control

– Alternate Fuels (such as naphtha,propane, low Btu)

• Lube Oil System

– Water/Oil Lube Cooler

– Electrostatic Demister

– Lube Oil Tank Heater

• Control System

– Remote Display/Control Terminal

– Heat Recovery Application Interface

– Serial Link Supervisory Interface

– KW Control

– KVAR/Power Factor Control

• Accessory Equipment

– Turbine Cleaning System: On-Crankand On-line

– Package Lifting Kit

• Ancillary Equipment: Various Air Inletand Exhaust Systems

– Inlet and Exhaust Silencers

– Self-Cleaning or Prefilter/BarrierAir Inlet Filter

– Inlet Evaporative Cooler

– Inlet Chiller Coils

– Ancillary Support Frame

• Onskid Microprocessor-Controlwith Auto Sync Capability

Industrial/Utility Grade

Solar Turbines IncorporatedP.O. Box 85376San Diego, CA 92186-5376

Caterpillar is a trademark of Caterpillar Inc.Solar and Saturn are trademarks of Solar Turbines Incorporated.Specifications subject to change without notice. Printed in U.S.A.©1998 Solar Turbines Incorporated. All rights reserved.DS20IPG/1198/5M

FOR MORE INFORMATION

Telephone: (+1) 619-544-5352Telefax: (+1) 619-544-2633Telex: 695045Internet: www.solarturbines.com

SATURN 20Gas Turbine Generator Set

Available PerformanceNominal Performance*

Output Power, kWeISO: 15°C (59°F), sea level 1210

Heat Rate, kJ/kWe-hr 14 741(Btu/kWe-hr) (13,972)

Exhaust Flow, kg/hr 23 220

(lb/hr) (51,240)

Exhaust Temperature, °C 516(°F) (960)

* No inlet or exhaust lossesRelative humidity 60%Natural gas fuel withLHV = 31.5 to 43.3 MJ/nm3

(800 to 1100 Btu/scf)

Typical Package Configuration

5.0 (17.1)

4.0 (13.6)

3.5 (12)

2.5 (8.5)300 (572)

350 (662)

400 (752)

450 (842)

500 (932)

550 (1022)

Exh

au

st F

low

, T

ho

usa

nd

s kg

/hr

(lb

/hr)

3.0 (10.2)

4.5 (15.4)

250 (482)

Full Load Output

Fuel Flow, MW (MMBtu/hr)

2.0 (6.8)

5.5 (18.8)

26 (

58)

25 (

56)

24 (

54)

23 (

52)

22

(5

0)

21

(4

8)

Exhaust Temperature, °C (°F)

500

OU

TP

UT

PO

WE

R A

T G

EN

ER

AT

OR

TE

RM

INA

L,

kWe

DS20IPG-002M

600

700

800

900

1000

1100

1200

1300

1400

1500

400

-30 (-22) -10 (14) 10 (50) 30 (86) 50 (122)

INLET AIR TEMPERATURE, °C (°F)

300

200

100

TURBINE AIRINLET CLEANER

LUBE OILCOOLER

PACKAGEGAUGE PANEL

ENCLOSUREVENT FAN

VENTSILENCER

ENCLOSUREVENT AIRINLET

PACKAGECONTROLCONSOLE

LUBE OILTANK HEATER

ENCLOSUREVENT AIREXHAUST

TURBINEEXHAUST

5982 mm(19' 7-1/2")813 mm(2' 8")

TURBINEAIR INLET

ENCLOSUREVENT AIREXHAUST

TURBINEAIR INLET

DS20IPG-003MWeight: 8980 kg (19,800 lb)

2134 m

m (

7' 0

")

1727 mm (5' 8")

(Inside)

(Inside)

TAURUS 60Gas Turbine Generator Set

Package Arrangement

Gas Turbine

• Taurus™ 60 Industrial, Single-Shaft

• Axial Compressor – 12 Stages

• Annular Combustion Chamber

– 12 Fuel Injectors

• Coatings

– Compressor: Inorganic Aluminum

– Turbine and Nozzle Blades:

Precious Metal Diffusion Aluminide

• Proximity Probe Vibration Transducers

Main Reduction Drive

• Epicyclic

– 1800 or 1500 rpm

– Acceleration Vibration Transducers

Generator

• Salient Pole, 3 Phase, 6 Wire,Wye Connected, Synchronous withBrushless Exciter

• Open Drip-Proof Construction

• Sleeve Bearings

• Velocity Vibration Transducers

• Solid-State Voltage Regulation withPermanent Magnet Generator

• NEMA Class F Insulation with F Rise

• Continuous Duty Rating

Package

• Steel Base Frame with Drip Pans

• Direct-Drive AC Start System

• Natural Gas Fuel System

Features

• Industrial Gas Turbine Package

• Compact, Integrated PackageProviding Ease of Installation

• Factory Tested

• Dry, Low Emission (SoLoNOx™)Combustion Available

• Control System

– Microprocessor-Based PLC

– Generator Control

– Vibration and Temperature Monitoring

– Auto Synchronizing

• Integrated Lube Oil System

– Turbine-Driven Lube Pump

– AC Pre/Post Lube Pump

– Backup Lube Pump

– Air/Oil Cooler

– Integral Lube Oil Tank

– Lube Oil Tank Heater

– Lube Oil Filter

• Documentation

– Drawings

– Quality Control Data Book

– Inspection and Test Plan

– Test Reports

– O&M Manuals

• Factory Testing of Turbine and Package

Optional Equipment/Services

• Generator Options:

– WPII, TEWAC

– Standby Duty Rating

– Standard Voltages:3300, 6600, 11,000 50 Hz;4160, 6900, 12,470, 13,800 60 Hz

• Fuel Systems

– Liquid

– Dual (Gas/Liquid)

– SoLoNOx, Dry, Low Emission

– Alternate Fuels (such as naphtha,propane, low Btu)

• Lube Oil System

– Water/Oil Lube Cooler

– Electrostatic Demister

– Duplex Lube Oil Filters

• Control System

– Remote Display/Control Terminal

– Heat Recovery Application Interface

– Serial Link Supervisory Interface

– KW Control

– KVAR/Power Factor Control

– Turbine Performance Map

– Historical Displays

– Printer/Logger

– Predictive Emissions Monitoring

– Field Programming Terminal

• Accessory Equipment

– 24-VDC Battery/Charger System

– Turbine Cleaning System: On-Crankand On-line

– Package Lifting Kit

• Weatherproof Acoustic Enclosure

• Ancillary Equipment: Various Air Inletand Exhaust Systems

– Inlet and Exhaust Silencers

– Self-Cleaning or Prefilter/BarrierAir Inlet Filter

– Inlet Evaporative Cooler

– Inlet Chiller Coils

– Ancillary Support Frame

• Onskid Microprocessor-Controlwith Auto Sync Capability

• Multiple Fuel Capability

Industrial/Utility Grade

Solar Turbines IncorporatedP.O. Box 85376San Diego, CA 92186-5376

Caterpillar is a trademark of Caterpillar Inc.Solar, Taurus and SoLoNOx are trademarks of Solar Turbines Incorporated.Specifications subject to change without notice. Printed in U.S.A.©1998 Solar Turbines Incorporated. All rights reserved.DS60IPG(5200)/1198/5M

FOR MORE INFORMATION

Telephone: (+1) 619-544-5352Telefax: (+1) 619-544-2633Telex: 695045Internet: www.solarturbines.com

TAURUS 60Gas Turbine Generator Set

Available PerformanceNominal Performance*

Output Power, kWeISO: 15°C (59°F), sea level 5200

Heat Rate, kJ/kWe-hr 11 882(Btu/kWe-hr) (11,263)

Exhaust Flow, kg/hr 79 284

(lb/hr) (174,798)

Exhaust Temperature, °C 486(°F) (906)

* No inlet or exhaust lossesRelative humidity 60%Natural gas fuel withLHV = 31.5 to 43.3 MJ/nm3

(800 to 1100 Btu/scf)

Forward End

• Turbine Control Box

Left Side

• Lube Oil: Drain, Vent, Cooler

• Generator Control Box, Power

• Generator Drip Pan Drain

• AC Power

– Lube Tank Heater

– Pre/Post Lube Pump

– Backup Lube Pump

Right Side

• AC Power - Start Motor

• Generator Monitor Box

Aft End

• Fuel Inlet

• Turbine Cleaning

• Fuel Filter, Combustor andExhaust Collector Drains

• Auxiliary Air (optional) for:

– Liquid Fuel Atomizing

– Self-Cleaning Filter

• AC Power

– Liquid Fuel Pump (optional)

• Package Ground

Typical Service Connections

OU

TP

UT

PO

WE

R A

T G

EN

ER

AT

OR

TE

RM

INA

L, M

We

7

6

5

4

3

2

1

-40 (-40) -20 (-4) 0 (32) 20 (68) 40 (104)

INLET AIR TEMPERATURE, °C (°F)

21 (72)

19 (65)

17 (58)

15 (51)

13 (44)

11 (38)

9 (31)

7 (24)

200 (392)

250 (482)

300 (572)

350 (662)

400 (752)

450 (842)

500 (932)

550 (1022)

89 (

196)

86 (

190)

83 (

183)

80 (

176)

77 (

170)

74 (

163)

71 (

157)

68 (

150)

Fuel Flow, MW (MM Btu/hr)

Full Load Output

Exh

aust

Flo

w,T

housa

nds

kg/h

r (lb/h

r)

Exhaust Temperature, °C (°F)

DS60IPG-002M

Length: 9754 mm (32’ 0”)

Width: 2438 mm (8’ 0”)

Height: 2591 mm (8’ 6”)

Approx.

Weight: 29 300 kg (64,590 lb)

DS60IPG-003M

Aft EndLeft SideForward End

Mobile Power - When and Where You Need It

Easy to Install and Relocate• Highway Transportable

• Modular Design for Quick Set-Upand Connection

• No Concrete Foundation Required

• Compact Footprint to Minimize SpaceRequirements

• Ideal for Rental Fleets and Utility

Equipment Pools

Environmentally Friendly• Low Emissions State-of-the-Art SoLoNOx™

Dry Low NOx Combustion System

• No Visible Emissions

• Sound Attenuation Package for Quiet Operation

• Low Profile Design to Minimize Installed Height

• Easy to Permit

The Taurus™ 60 Mobile Power Unit is the prime choice if you’re looking to produce reliable, low-cost, onsitepeaking power. Designed as an onsite generator system to optimize service for seasonal or cyclical loads, theTaurus 60 Mobile Generator System includes these key features:

Flexible Solution

• Leasing and Rental Options Available

• 5-MW Size for Highly Flexible Capacity Additionand Operation

• Fuel Flexibility, Gas or Diesel with Dual Fuel Option

Complete Systems Solution• Set-Up and Commissioning

• Site Preparation (if needed)

• Ancillary Support Systems (if needed)

• Wide Range of Product Support Programs

Operational Features• Dispatchable to be On Line in Six Minutes

(from cold start)

• Range of Control System Options for RemoteOperation and SCADA Integration

• Utility Grade Switchgear and ProtectiveRelay Module

• KVAR Control for Excellent ReactivePower Capability

TAURUS 60Mobile Power Unit

Solar Turbines IncorporatedP.O. Box 85376 MZ SP3-QSan Diego, CA 92186-5376 U.S.A.

Caterpillar is a trademark of Caterpillar Inc.Solar, Taurus and SoLoNOx are trademarks of Solar Turbines Incorporated.Specifications subject to change without notice. Printed in U.S.A.©2002 Solar Turbines Incorporated. All rights reserved.DS60MPU/702/4M

FOR MORE INFORMATIONTelephone: (+1) 619-544-5352Telefax: (+1) 858-694-6715

E-mail: [email protected]: www.solarturbines.com

TAURUS 60Mobile Power Unit

Nominal Generator SetPerformance

Typical Dimensions

Output Power, kWeISO: 15°C (59°F), sea level 5,500

Heat Rate, Btu/kWe-hr 11,263

At the core of the Mobile Power Unit is the 5.5 MW

Taurus 60 industrial gas turbine, with a population of

more than 1085 units in the field. The Mobile Power Unit

combines the features and benefits of the proven

Taurus 60 industrial gas turbine with a mobile system

that is easy to relocate and connect.

For information on price, delivery and how the

Taurus 60 Mobile Power Unit can meet your needs

for short-term capacity and reduce your exposure

to market spikes, e-mail: [email protected]

or call (858) 694-6570.

Sited Configuration of Taurus 60 Mobile Power Unit

Mobile Power -When and Where You Need It

EXHAUST STACK AND SILENCER

ATOMIZINGAIR COMPRESSOR

GAS FUELFILTER

TURBINE INLET AIR FILTER

TAURUS 60 GEN SET

PREFABRICATED POWERCONTROL ROOM

ACCESS PLATFORM

OIL MIST ELIMINATOR

8' 6

"

5' 1

/4"

5' 3

"

4' 0

"

PREFABRICATED POWERCONTROL ROOM

GROUND

RESISTOR

25

' 0"

3' 6

"

13

' 10

"

27' 0" 12' 1"6' 10"

UP

UP

GROUND

RESISTOR

AUXILIARY

TRANSFORMER

AUXILIARY

TRANSFORMER

LUBE OIL

COOLER

LUBE OIL

COOLER

INSTALLATION PLAN VIEW

POWER CONTROL MODULE

TRAILER

TRAILER

GENERATOR MODULE

LIQUID FUELFILTER SKID

GAS FUELMETER

TURBINE INLETAIR FILTER

OIL MISTELIMINATOR

14

' 7/8

"

23

' 7"

8' 6

"

EXHAUST STACK

EXHAUST SILENCER

LIQUID FUELFILTER SKID

ATOMIZINGAIR COMPRESSOR

10

' 0"

8' 7

"5

' 4-1

/2"

INLET AIR TEMPERATURE, ˚C (˚F)

45(113)

30(86)

15(59)

0(32)

-15(5)

OU

TP

UT

PO

WE

R, K

We

6500

6000

5500

5000

4500

4000

3500

OUTPUT POWER

TAURUS 70Gas Turbine Generator Set

Gas Turbine

• Taurus™ 70 Industrial, Single-Shaft

• Axial Compressor

– 14-Stage

– Variable Inlet Guide Vanesand Stators

– Compression Ratio 16:1

– Inlet Airflow: 26.2 kg/sec(57.7 lb/sec)

– Speed: 15,200 rpm

– Vertically Split Case

• Annular Combustion Chamber

– Conventional or Lean-Premixed,

Dry, Low Emission (SoLoNOx)

– 12 Fuel Injectors

– Torch Ignitor System

• Proximity Probe VibrationTransducers

• Turbine

– 3-Stage, Axial Flow

– Speed: 15,200 rpm

Main Reduction Drive

• Epicyclic

– 1500 or 1800 rpm (50 or 60 Hz)

– Acceleration Vibration Transducer

Generator

• Continuous Duty Rating

• Salient Pole, 3 Phase, 6 Wire,Wye Connected, Synchronous withBrushless Exciter

• Permanent Magnet Generator

• Open Drip-Proof Construction

• Sleeve Bearings

• Velocity Vibration Transducers

• NEMA Class F Insulation with F Rise

Package

• Steel Base Frame with Drip Pans• Direct-Drive AC Start System• Natural Gas Fuel System• Turbotronic™ 4 Control System

– ControlLogix Processor– Standard Display with Discrete

Event Log, Strip Chart, HistoricalTrend, Maintenance Screen

– Gas Turbine and Generator Control– Vibration and Temperature

Monitoring– Auto Synchronizing– KW Control– CGCM Module– KVAR/Power Factor Control

(Optional)– Combination Generator Control

Module with Load Share,Synchronization, Voltage Control,Reactive Power Control, GeneratorProtection

• Integrated Lube Oil System– Turbine-Driven Lube Pump– Pre/Post Lube Pump– Backup Lube Pump– Air/Oil Cooler– Integral Lube Oil Tank– Lube Oil Tank Heater– Simplex Lube Oil Filter– Oil Mist Eliminator

• Documentation– Drawings– Quality Control Data Book– Inspection and Test Plan– Test Reports– Operation and Maintenance

Manuals• Turbine Cleaning System:

On-Crank and On-Line• Factory Testing of Turbine and

Package

Optional Equipment

Industrial/Utility Grade

Standard Package Configurations

• Generator Options:

– Totally Enclosed Water/Air Cooled

– Standard Voltages:6600, 11,000 V (50 Hz);4160, 12,470, 13,800 V (60 Hz)

• Fuel Systems

– Liquid

– Dual (Gas/Liquid)

– Alternate Fuels (such as naphtha,propane, low Btu gas)

– ElectricFuel Control

• Lube Oil System

– Water/Oil Lube Oil Cooler

– Duplex Lube Oil Filters

– Vent Flame Trap

• Control System

– Auxillary and Remote Display/Control Terminal

– Heat Recovery ApplicationInterface

– Serial Link Supervisory Interface

– Turbine Performance Map

– Historical Displays

– Printer/Logger

– Field Programming Terminal

• Accessory Equipment

– 120-VDC Battery/Charger System

– Package Lifting Kit

• Weatherproof Acoustic Enclosure

• Ancillary Equipment:

– Inlet and Exhaust Silencers

– Self-Cleaning or Prefilter/BarrierAir Inlet Filter

– Inlet Evaporative Cooler

– Inlet Chiller Coils

– Ancillary Support Frame

Solar Turbines IncorporatedP.O. Box 85376San Diego, CA 92186-5376 U.S.A.

Caterpillar is a trademark of Caterpillar Inc.Solar, Taurus, SoLoNOx and Turbotronic are trademarks of Solar Turbines IncorporatedAll other trademarks are the intellectual property of their respective companies..Specifications subject to change without notice. Printed in U.S.A.© 2003 Solar Turbines Incorporated. All rights reserved.DS70PG/103/1M

FOR MORE INFORMATION

Telephone: (+1) 619-544-5352Telefax: (+1) 858-694-6715Internet: www.solarturbines.com

TAURUS 70Gas Turbine Generator Set

Available PerformanceNominal Performance*

Output Power, kWe 7520

ISO: 15°C (59°F), sea level

Heat Rate, kJ/kWe-hr 10 650

(Btu/kWe-hr) (10,100)

Exhaust Flow, kg/hr 97 000

(lb/hr) (213,840)

Exhaust Temperature, °C 490

(°F) (910)

* No inlet or exhaust lossesRelative humidity 60%Natural gas fuel with

LHV = 31.5 to 43.3 MJ/nm3

(800 to 1100 Btu/scf)

Left Side

• Lube Oil: Cooler, Drain, Vent

• AC Power

– Starter Motor

– Liquid Fuel Pump

– Pre/Post Lube Pump

– Oil Tank Heater

• Package Ground

• DC Power, Backup Lube Pump

• Lube Oil Tank Drain

Aft End

• Combustor and ExhaustDiffuser Drains

• Fuel: Inlet, Filter, Drain, Vent

• Auxiliary Air (optional) for:

– Liquid Fuel Atomizing

– Self-Cleaning Filter

• Turbine Cleaning

• Turbine Drip Pan Drain

Typical Service Connections

Length: 11 278 mm (37’ 0”)

Width: 2932 mm (9’ 7-7/16”)

Height: 2743 mm (9’ 0”)

Approximate Weight (dry):

50 314 kg (110,923 lb)

Package Dimensions

Forward End

• Turbine Control Box

• Generator Drip Pan Drain

• Package Ground

• Generator Control Box

• Generator Terminal Box

DS70IPG-003M

Forward End Left Side Aft End

F16F16F15F15F14F14F13F13F12F12F11F11F10F10F9F9

F8F8F7F7F6F6F5F5F4F4F3F3F2F2F1F1

7 8 9

4 5 6

1 2 3

. 0 -

10105 6 7 8 9

1 2 3

16161111 1212 1313 1414 1515

22221717 1818 1919 2020 2121

4

28282323 2424 2525 2626 2727

11

9

7

5

3

1-40 (-40) -20 (-4) 0 (32) 20 (68) 40 (104)

INLET AIR TEMPERATURE, ˚C (˚F)

OU

TP

UT

PO

WE

R A

T G

EN

ER

AT

OR

TE

RM

INA

L, M

We

24 (82)

22 (75)

18 (61)

14 (48)

10 (34)

250 (482)

300 (572)

400 (752)

450 (842)

500 (932)

108 (238)

104 (229)

100 (220)

96 (212)

92 (203)

88 (194)

84 (185)

Fuel Flow, MW (MM Btu/hr)

Exhaust Flow, Thousands kg/hr (lb/hr)

Exhaust Temperature, ˚C (˚F)

DS70IPG-002M

Full Load Output

350 (662)

12 (41)

16 (55)

20 (68)

26 (89)

Right Side

• Lube Oil Tank Vent