Fall 2015 Petroleum Systems Services Corporation ... - PSSC · The PSSC Pipeline PSSC • 2789...
Transcript of Fall 2015 Petroleum Systems Services Corporation ... - PSSC · The PSSC Pipeline PSSC • 2789...
PSSC has added additional
employees as well as several
new product lines over the
years to serve our customer’s
needs.
As we continue forward, we
never forget where we started
- as a company where
customer service and
satisfaction are the primary
goals.
Fall 2015 Petroleum Systems Services Corporation Vol, 25 Page 1
Your one source shop for
Grabner & Eralytics RVP
service
• Traceability to NIST standards
• Replacement calibration certificates
during your crucial ISO audit
• 22 years in business
• Over 100 years combined Vapor
Pressure Experience
Vapor Pressure Service Professionals - Experience counts.
Automatic Pensky-Martens Closed Cup Flash Point Analyzer
Specifications • Conforms to the specifications of: ASTM D93 Procedure A, B & C; IP 34; ISO 2719; DIN EN 22719;
JIS K2265;
• Detection System: Thermocouple and Ionization Ring
• Heating Rate: In accordance to ASTM D93 procedure A, B and C
• Stirring Rate: 0 to 300 ± 5 RPM
• Cycle Time: 5 minutes as per rapid fan cooling system
• Barometric Pressure: Automatic Pressure Correction
• Flash Temperature Correction
• Safety: Fire prevention, detection, and suppression systems standard
Test Method For flash point determination of biodiesel, distillate fuels, new lubricating oils, residual fuel
oils, cutback residue, used lubricating oils, mixtures of petroleum liquids with solids, and
petroleum liquids that tend to form a surface film during testing.
Part Number: KI-71000
PSSC • 2789 Route 9 • Malta, NY 12020 • (518) 581-0189 • [email protected] • www.pssc.org
Call PSSC for
ordering information
or visit our website
The PSSC Pipeline
PSSC • 2789 Route 9 • Malta, NY 12020 • (518) 581-0189 • [email protected] • www.pssc.org
CFR 40 part 80.47 updated to reflect changes in effect January 1st, 2016
ASTM D2622-10 Sulfur in gasoline:
2622 is now the only sulfur test method not required to meet the new precision and accuracy criteria for performance based test methods.
ASTM D2622-10
The "Referee" for January 1st, 2016 CFR 40 Part 80.47
Please call or email PSSC and we will be
happy to assist you.
A Few Benefits to Using This Service:
• 100% Financing Available
• Competitive Rates
• Increased Cash Flow
• Rent-to-Own Option
Fall 2015 Petroleum Systems Services Corporation Vol, 25 Page 2
Clora M-series
The Clora Bench-Top analyzer
is a compact Chlorine analyzer,
designed for use with liquid
hydrocarbons such as aromatics,
distillates, heavy fuels and
crude oils, as well as aqueous
solutions.
Clora 2XP
The Clora 2XP Benchtop analyzer
is ideal for testing related to
catalyst poisoning in reformers
or for sites with fluid catalytic
crackers and hydrocrackers
monitoring very low levels of
chlorine.
Total Chlorine analysis from aqueous solutions and aromatic products
to heavy fuels, crudes and catalyst
Features and Benefits:
• LOD: 0.013 ppm wt. in hydrocarbons
• Dynamic range:
0.013 ppm wt. up to 3000 ppm wt. • XR Package: 0.13 ppm wt. up to 4% wt.
• Automatic sulfur correction
• Extremely low maintenance
- No conversion gasses
- No columns
- No heating elements
- No quartz tubing
• Plug-it-in and measure
• User-friendly with touch screen
interface
• User programmable measurement
time: 30-900 s
• Replaceable air-cooled x-ray tube
• No sample conversion or
combustible gasses required
• Robust polyamide window for
easy cleaning
XOS & PSSC Your Partners in Lab and Process Automation
The PSSC Pipeline
PSSC • 2789 Route 9 • Malta, NY 12020 • (518) 581-0189 • [email protected] • www.pssc.org
Fall 2015 Petroleum Systems Services Corporation Vol, 25 Page 3
OUR NEOHEXANE SUPPLIER HAS INFORMED US
THAT THERE IS NO LONGER A DELIVERY DATE
FOR THE 2,2-DIMETHYLBUTANE (NEOHEXANE),
PLEASE CONSIDER THIS FOR FUTURE PLANS.
MEET THE STAFF! Nicole Barnes
Many of you have already spoken
to her, but we’d like to officially
welcome one of the newest
members to our team. Nicole has
been here almost a year now,
helping out in the shipping,
accounting and marketing
departments. Let’s all wish her
continued success here at PSSC!
accounting and marketing departments. She
comes in every day full of energy and always
ready to tackle a new task. She has a willingness
to learn and constantly improve. Let’s all wish her
continued success here at PSSC!
Jeffrey Kirkland, PhD
Corporation, a biofuels company where he was a
member of the R&D department in San Diego,
CA. We expect that Jeffrey’s chemical knowledge
and perspective will help PSSC better service your
analytical needs.
We are excited to welcome Dr.
Jeffrey R. Kirkland to our team of
vapor pressure experts. Jeffrey
brings experience to PSSC from
Colorado State University, Rutgers
University, and Verenium
Corporation, a biofuels company
where he was a member of the R
and D department in San Diego,
CA. We expect that Jeffrey’s
chemical knowledge and
perspective will help PSSC better
service your analytical needs.
Dates: December 06 2015 - December 10 2015
Location: JW Marriott Austin; Austin, TX USA
MARK YOUR CALENDARS!
ASTM D02 MEETING