Fall 2015 Petroleum Systems Services Corporation ... - PSSC · The PSSC Pipeline PSSC • 2789...

3
PSSC has added additional employees as well as several new product lines over the years to serve our customer’s needs. As we continue forward, we never forget where we started - as a company where customer service and satisfaction are the primary goals. Fall 2015 Petroleum Systems Services Corporation Vol, 25 Page 1 Your one source shop for Grabner & Eralytics RVP service • Traceability to NIST standards • Replacement calibration certificates during your crucial ISO audit • 22 years in business • Over 100 years combined Vapor Pressure Experience Vapor Pressure Service Professionals - Experience counts. Automatic Pensky-Martens Closed Cup Flash Point Analyzer Specifications • Conforms to the specifications of: ASTM D93 Procedure A, B & C; IP 34; ISO 2719; DIN EN 22719; JIS K2265; • Detection System: Thermocouple and Ionization Ring • Heating Rate: In accordance to ASTM D93 procedure A, B and C • Stirring Rate: 0 to 300 ± 5 RPM • Cycle Time: 5 minutes as per rapid fan cooling system • Barometric Pressure: Automatic Pressure Correction • Flash Temperature Correction • Safety: Fire prevention, detection, and suppression systems standard Test Method For flash point determination of biodiesel, distillate fuels, new lubricating oils, residual fuel oils, cutback residue, used lubricating oils, mixtures of petroleum liquids with solids, and petroleum liquids that tend to form a surface film during testing. Part Number: KI-71000 PSSC • 2789 Route 9 • Malta, NY 12020 • (518) 581-0189 • [email protected] • www.pssc.org Call PSSC for ordering information or visit our website

Transcript of Fall 2015 Petroleum Systems Services Corporation ... - PSSC · The PSSC Pipeline PSSC • 2789...

PSSC has added additional

employees as well as several

new product lines over the

years to serve our customer’s

needs.

As we continue forward, we

never forget where we started

- as a company where

customer service and

satisfaction are the primary

goals.

Fall 2015 Petroleum Systems Services Corporation Vol, 25 Page 1

Your one source shop for

Grabner & Eralytics RVP

service

• Traceability to NIST standards

• Replacement calibration certificates

during your crucial ISO audit

• 22 years in business

• Over 100 years combined Vapor

Pressure Experience

Vapor Pressure Service Professionals - Experience counts.

Automatic Pensky-Martens Closed Cup Flash Point Analyzer

Specifications • Conforms to the specifications of: ASTM D93 Procedure A, B & C; IP 34; ISO 2719; DIN EN 22719;

JIS K2265;

• Detection System: Thermocouple and Ionization Ring

• Heating Rate: In accordance to ASTM D93 procedure A, B and C

• Stirring Rate: 0 to 300 ± 5 RPM

• Cycle Time: 5 minutes as per rapid fan cooling system

• Barometric Pressure: Automatic Pressure Correction

• Flash Temperature Correction

• Safety: Fire prevention, detection, and suppression systems standard

Test Method For flash point determination of biodiesel, distillate fuels, new lubricating oils, residual fuel

oils, cutback residue, used lubricating oils, mixtures of petroleum liquids with solids, and

petroleum liquids that tend to form a surface film during testing.

Part Number: KI-71000

PSSC • 2789 Route 9 • Malta, NY 12020 • (518) 581-0189 • [email protected] • www.pssc.org

Call PSSC for

ordering information

or visit our website

The PSSC Pipeline

PSSC • 2789 Route 9 • Malta, NY 12020 • (518) 581-0189 • [email protected] • www.pssc.org

CFR 40 part 80.47 updated to reflect changes in effect January 1st, 2016

ASTM D2622-10 Sulfur in gasoline:

2622 is now the only sulfur test method not required to meet the new precision and accuracy criteria for performance based test methods.

ASTM D2622-10

The "Referee" for January 1st, 2016 CFR 40 Part 80.47

Please call or email PSSC and we will be

happy to assist you.

A Few Benefits to Using This Service:

• 100% Financing Available

• Competitive Rates

• Increased Cash Flow

• Rent-to-Own Option

Fall 2015 Petroleum Systems Services Corporation Vol, 25 Page 2

Clora M-series

The Clora Bench-Top analyzer

is a compact Chlorine analyzer,

designed for use with liquid

hydrocarbons such as aromatics,

distillates, heavy fuels and

crude oils, as well as aqueous

solutions.

Clora 2XP

The Clora 2XP Benchtop analyzer

is ideal for testing related to

catalyst poisoning in reformers

or for sites with fluid catalytic

crackers and hydrocrackers

monitoring very low levels of

chlorine.

Total Chlorine analysis from aqueous solutions and aromatic products

to heavy fuels, crudes and catalyst

Features and Benefits:

• LOD: 0.013 ppm wt. in hydrocarbons

• Dynamic range:

0.013 ppm wt. up to 3000 ppm wt. • XR Package: 0.13 ppm wt. up to 4% wt.

• Automatic sulfur correction

• Extremely low maintenance

- No conversion gasses

- No columns

- No heating elements

- No quartz tubing

• Plug-it-in and measure

• User-friendly with touch screen

interface

• User programmable measurement

time: 30-900 s

• Replaceable air-cooled x-ray tube

• No sample conversion or

combustible gasses required

• Robust polyamide window for

easy cleaning

XOS & PSSC Your Partners in Lab and Process Automation

The PSSC Pipeline

PSSC • 2789 Route 9 • Malta, NY 12020 • (518) 581-0189 • [email protected] • www.pssc.org

Fall 2015 Petroleum Systems Services Corporation Vol, 25 Page 3

OUR NEOHEXANE SUPPLIER HAS INFORMED US

THAT THERE IS NO LONGER A DELIVERY DATE

FOR THE 2,2-DIMETHYLBUTANE (NEOHEXANE),

PLEASE CONSIDER THIS FOR FUTURE PLANS.

MEET THE STAFF! Nicole Barnes

Many of you have already spoken

to her, but we’d like to officially

welcome one of the newest

members to our team. Nicole has

been here almost a year now,

helping out in the shipping,

accounting and marketing

departments. Let’s all wish her

continued success here at PSSC!

accounting and marketing departments. She

comes in every day full of energy and always

ready to tackle a new task. She has a willingness

to learn and constantly improve. Let’s all wish her

continued success here at PSSC!

Jeffrey Kirkland, PhD

Corporation, a biofuels company where he was a

member of the R&D department in San Diego,

CA. We expect that Jeffrey’s chemical knowledge

and perspective will help PSSC better service your

analytical needs.

We are excited to welcome Dr.

Jeffrey R. Kirkland to our team of

vapor pressure experts. Jeffrey

brings experience to PSSC from

Colorado State University, Rutgers

University, and Verenium

Corporation, a biofuels company

where he was a member of the R

and D department in San Diego,

CA. We expect that Jeffrey’s

chemical knowledge and

perspective will help PSSC better

service your analytical needs.

Dates: December 06 2015 - December 10 2015

Location: JW Marriott Austin; Austin, TX USA

MARK YOUR CALENDARS!

ASTM D02 MEETING