A R C H I T E C T A N D FAC I L I T Y M A NAG E M E N T G U I D E
Entrance Systemsfor Health Care
Horton Entrance Systemsfor Health Care
The automatic choice for performance,convenience and peace of mindHospitals and medical facilities have highly specialized access needs that
drive some of the toughest building codes in North America. In these
facilities, patients must be moved safely and often swiftly. Extra safeguards
must be in place related to fire, smoke, wind, security and dozens of other
critical considerations. Each facility must also host hundreds and even
thousands of staff and visitors that pass through its doors each day.
And it must do all of that efficiently in a 24/7 environment where
the doors are never closed. That is health care today. And that is
the world of Horton Automatics, the industry leader in door
systems for hospitals, out-patient care clinics, nursing
homes and other medical facilities.
“We are glad to have collaborated with Horton Automatics on the
SouthwestWashington Medical Center project. Not only did Horton meet
stringent time and quality requirements, but they also implemented
aesthetic and superior design that helped us differentiate our offering.”
Leigh Sutphin, PrincipalNBBJ
Client: Southwest Washington Medical Center, Vancouver, Washington(front cover photo)
2
Linear drive operators for slidingdoors provide smooth, quietoperation and long life.
Rugged Corner Block Construction – A Horton Exclusive!Heavy duty rail design with integral corner blocks adds structuralintegrity to all Horton door systems. Mortise-style corner blockconstruction is far superior to mass produced through-bolt panels.
Four #10-24 boltssecure corner blockto horizontal rail
Two Grade 8, 1/4-20bolts secure cornerblock to vertical rail
Concave steel back-up plate engineeredas built-in selflocking device forGrade 8 bolts
Simple adjustments for open-closespeeds and actuation allow Horton swing
door systems to adapt to your facility’schanging needs.
Smooth operatorsPreferred by architects for sleek aesthetics as well as
durability, Horton operators are also the choice of facility
managers for low maintenance. Horton operators meet
virtually any high or low energy access need.
Integrated solutionsCombining Horton doors, controls, sensors and other access
solutions throughout your facility will allow you to reduce
maintenance worries and confusion. Consider an integrated
Horton platform for ultimate continuity in facility design
and management.
Specify Horton quality andreliability for your facilityAmong the top concerns of any health care facility
manager is that a major entrance must be shut down and
traffic re-routed. With Horton long life operators and high
strength doors, you are choosing the most reliable door
systems available. And if service is needed, Horton
distributors are available to fix the problem promptly and
keep your entrances functioning.
Depend on HortonProfessional Service
Did you know that access issues and
properly maintained door systems
are now an important component of
JCAHO* inspections? Ask your Horton
Automatics distributor to provide
regular preventive maintenance that
will help assure swift approval on
this portion of your accreditation.
* Joint Commission on Accreditationof Healthcare Organizations
3
Folding DoorsOur folding doors are used for entrances as
well as corridors that require a wide opening
but cannot accept a conventional door
because of space limitations.
Swing DoorsDesigned for high traffic entrances providing
convenience and reliability. The variety of
header designs will satisfy any architectural
requirement.
Solutionsdesigned tomeet specifichealth careapplicationrequirements.
Main Entrances
Emergency
Administration
Intensive Care
Cardiac Care
Corridors
Department Entrances
Patient Rooms
Pharmacy
Admissions
Accounts Payable
Gift Shop
4
Revolving DoorsTurn an ordinary entrance into an energy-
efficient vestibule system. This large
diameter automatic revolving entrance
easily accommodates mobile beds.
Sliding DoorsOur broad offering of sliding doors gives
you a wide range of choices to meet your
exacting requirements for size, color, and
finish as well as function, grade of
construction and security.
ICU/CCU DoorsPatients are always in full view through
the sliding glass door. The full breakaway
feature allows for all panels to swing out
of the way providing a large opening for
swift removal of patients or equipment.
Fire Rated DoorsOffering the cleanest possible installation
for fire rated applications in hospitals
and other health care facilities requiring
an automated fire door system.
5
Add security plusconvenience for drive-up
or walk-up traffic inpharmacies, labs and
other areas.
Revolving & SlidingDoor Applications
Main Entrances
Emergency
Administration
Grand® large diameter vestibule systemSpacious compartments provide an elegant, energy-efficient entrance up
to 16 ft. in overall diameter to manage high volume traffic needs including
wheel chairs, walkers and even hospital stretchers.
Easily customized with special finishes, metal cladding, roofpanel designs, Segmented® or round wall design as well asextended canopies
Choice of 3- or 4-wing models, all with quiet, smooth operationand emergency egress panels that fold against the core
Constant seal helps control energy costs and eliminates drafts
VistaScan™ electronic sensing system slows or stops the doorwhen objects are within 10" of the wings
Voice messages announce door slowing, resuming speed and“please step forward”
StormLock™ feature for high wind conditions
AutoFlow™ revolving systems rotateon approach, allow reduced speedsetting for wheel chairs
Glass ceilings and other custom touchesadd drama along with function.
Revolving Doors
ARCHITECT TOOLS:Specs - www.hortondoors.com/Specifications/specifications.htmlCAD Files - www.hortondoors.com/Drawing/drawings.html
Selection GuideType Inside Diameter Entry - 3 Wing Entry - 4 Wing
Manual 6' to 8' up to 3' 9 1⁄8" up to 5' 7 15⁄16"
Security 6' to 7' — up to 4' 8 13⁄16"
Automatic 9' to 10' up to 4' 7 3⁄8" up to 6' 9 5⁄16"
Segmented® Drum Round DrumOutside Diameter Entry - 3 Wing Entry - 3 Wing
MiniGrand® 11' to 12' up to 5' 3⁄4" up to 5' 2 3⁄16"
Outside Diameter Entry - 3 Wing Entry - 4 Wing
Grand® 12' to 16' up to 7' 3⁄8" up to 10' 7"
Entry
Outside Diameter
E
Wing
W
3-Wing
4-Wing
6
“Horton Automatics
consistently provides
excellent pre-
construction services.
They understand
our clients’ clinical
requirements and
their local
distributor is also
very responsive after
installation to meet
ongoing needs
of the medical
facilities we build.”
Chad R. PaaschProject ManagerM. A. MortensonCompanyMinneapolis, Minnesotawww.mortenson.com
Entry
Outside Diameter
W
Wing
MiniGrand®
The MiniGrand® offers the drum constructionof a Grand® and the center shaft and doorwing construction of an AutoFlow.®
7
Profiler® 2000 linear drive systemThese automatic sliding door systems are used in a wide range of health care
applications, both interior and exterior. Custom-manufactured to your
specifications, they are ADA compliant when properly specified and meet all
construction, safety and security requirements.
Unlimited custom options for size and finish
High strength corner block construction ensures durability fortrouble-free operation
Door panels break out for emergency egress
Advanced microprocessor controls with built-in diagnostics
Dual safety beams for added threshold protection
Selectable operating modes (day/night, hold open,one-way/two-way, partial opening, off)
Sliding Doors
ProSlide™ telescoping doors increaseclear openings by more than 35% inlimited spaces.
Elegant® all-glass system withheavy-duty belt drive system
Type 110
41 3/4"
Type SX-O(O-SX Reverse)
OptionalMuntinBar
24"
48"
SafetyBeams
8
8' to 16'7' to 9'
Type O-SX-SX-O
7
Type SX-O (O-SX Reverse) Type O-SX-SX-O
48"
24"
SafetyBeams
8' to 14'7' to 9'
4
Type 110
Type 110
SafetyBeams
48"
24"
Type SX-X-O(O-X-SX Reverse)
Optional Muntin Bar
O
7' to 12'
T
Selection Guide Breakout OpeningModel Type Unit Width Max Slide Opening Type 110 Type 310
Profiler® Single Slide 7' to 9' 3' to 4' 3' 31⁄2" to 4' 31⁄2" 6' 3" to 8' 3"Bi-part 8' to 16' 3' to 7' 3' 7" to 7' 7" 6' 91⁄2" to 14' 91⁄2"
Elegant® Single Slide 6' to 8' 2' 71⁄2" to 3' 8" 2' 71⁄2" to 3' 8" —Bi-part 8' to 14' 3' 4" to 6' 4" 3' 4" to 6' 4” —
ProSlide™ Half Telescoping 7' to 12' 3' 71⁄2" to 6' 111⁄2" 2' 1" to 3' 9" 5' 91⁄2" to 10' 91⁄2"Telescoping Bi-part 8' to 16' 3' 51⁄2" to 8' 91⁄2" 2' 3" to 4' 11" 5' 101⁄2" to 13' 101⁄2"
Manual SlidingDoor Applications
Intensive Care
Cardiac Care
Profiler-ICU® manual sliding door systemDesigned and built specifically for the critical care environment of ICU/CCU
operations, these multi-function doors keep patients in full view when closed.
The panels also slide as well as swing out to provide maximum clearance for
beds and equipment.
Choice of 2-, 3- or 4-panel designs as well as custom configurations
Trackless design option for easier installation and a smooth floor surface
Engineered with the same strong corner block design as ourautomatic door systems
Recessed pull handles (standard), optional positive latch sets
Selection Guide Breakout OpeningUnit Width Max Slide Opening Type 110 Type 310
Single Slide 7' to 9' 3' to 4' 3' 31⁄2" to 4' 31⁄2" 6' 3" to 8' 3"
Bi-Part 8' to 16' 3' to 7' 3' 7" to 7' 7" 6' 91⁄2" to 12' 91⁄2"
Half-Telescoping 7' to 12' 4' 2" to 7' 6" — 6' 1" to 11' 1"
Multi-access design allows clearmonitoring of the room (top) plussliding access (middle) as well aseasy breakaway (bottom) to movepatients.
Custom corner configuration shown
ICU/CCU Sliding Doors
Up to 16'
Type SX-SO (SO-SX Reverse)
OptionalMuntin Bar
41 3/4"
7' to 9'
Type SO-SX-SX-SO
7'2
1/2"
Type 310
Type 110
Type 310
48"
24"
Type SX-SX-SO(SO-SX-SX Reverse)
T
SafetyBeams
7' to 12'
S
Optional Muntin Bar
7
Up to 16'
41 3/4"
Type SX-O (O-SX Reverse)
OptionalMuntin Bar
7' to 9'
7'2
1/2"
Type O-SX-SX-O T
8
9
Modified door nosings, bottom railsand interlock seals exceeds smokeinfiltration requirements of UL 1784.
Note: Consult factory fornewest configurations.
Profiler-ICU® Smoke Rated manual entrance solutionsThis door series provides flexible access to ICU/CCU patients along with smoke protection
per UL 1784 and NFPA standard 105.
Concealed high temperature weather-sweep and gasket design
Positive latching handle
Low-profile header for superior aesthetics
Slide doors available in trackless or recessed track configurations
SmokeSwing™ doors available in single, equal or unequal pair
Selection Guide Max Slide Opening Max Slide Opening Breakout OpeningUnit Width Type 110 & 310 Type 310 Trackless Type 110 Type 310
Single Slide 7' to 9' 3' to 4' 2' 9" to 3' 9" 3' 31⁄2" to 4' 31⁄2" 6' 3" to 8' 3"
SmokeSwing™ DimensionsDoor Width
Single up to 48"Equal Pair up to 48"Unequal Pair up to 48"
ARCHITECT TOOLS:Specs - www.hortondoors.com/Specifications/specifications.html
CAD Files - www.hortondoors.com/Drawing/drawings.html
Type SX-SO (SO-SX Reverse)
7' to 9'
"2/12'7
OptionalMuntinBar
Type SX-O (O-SX Reverse)
7' to 9'
"2/12'7
41 3/4"
OptionalMuntinBar
U
Unit width
Unit
heig
ht
Type 310
Type 110
SmokeSwing™ Pair
HD-Swing® fire door packageThe all-in-one fire rated steel door system, Series 4900DP is a popular
choice for hospital corridors where maximum clear opening is important.
It is designed for high traffic use and complies with ANSI requirements
for full energy (automatic) operation.
Swing DoorApplications
Entrances
Corridors
Department Barriers
Patient Rooms
Series 4900DP packages include 18-gauge steel doors, frame,exit device and Series 4000 heavy-duty operator
Push-N-Go® function activates the door when pushed, SoftTouch®
reopens door if obstructed during closing
All hardware is factory installed for accurate alignment and timesaving installation.
Selection GuideDoor Width
Single Doors 3' 6" to 4' 3"
Pair of Doors 7' to 8' 6"
Low-profile push bar protrudes only1/2" for double egress doors in fullopen position, 1-1/16" for single orpairs of doors.
One-source solution incorporates a heavyduty operator concealed in the header.
Swing Doors
ARCHITECT TOOLS:Specs - www.hortondoors.com/Specifications/specifications.htmlCAD Files - www.hortondoors.com/Drawing/drawings.html
Header–Vertical Section
Top View
Door Panel with Power Arm
Operator
Wal
l
Door Panel
Operator
Steel Header
10
EasyAccess® low energy handicap operatorThe Series 7000 operator is ideal for new or converted
barrier-free openings per ANSI A117/156.19, ADA and local
building codes. Standard features include:
Automatic opening with button or push plate activation
Easily adjustable opening and closing speeds
Operator can be surface applied or overhead concealed
Push-N-Go® feature, SoftTouch® reversing and obstruction sensing
FoldingAccess® door system
Ideal for hospital corridors and vestibules that
require wide openings in a limited space, these
automatic folding doors incorporate Vista™
sensing technology.
Selection GuideUnit Width Opening Width
Single (2 door panels) 3' 5" to 4' 2' 811⁄16" to 3' 11⁄16"
Pair (4 door panels) 6' to 8' 4' 47⁄8" to 6' 47⁄8"
Emergency breakout
Finger guard at all hinge points
Accommodates 1-way or 2-way traffic
Also available in manual opening stylesfor ICU applications
Folding Doors
Folding DoorApplications
Corridors
Entrances
ICU
HD-Swing® LE low energy heavy duty handicap operator
Ideal for use with heavy doors, HD-Swing 4000LE series operators
exceed handicap access requirements of ANSI A117/A156.19 as
well as demands of high traffic hospital environments. Standard
features include:
Easy switching to full energy (automatic) operation
Heavy duty for larger doors
Choice of in-swing, out-swing, left or right handed operation
Fold Out-Type LHR-RHRFold In-Type LH-RH
6' to 8'
7'6"
Unit
Ht. Optional
MuntinBar
Fold Out-Type RHR (LHR Opposite)Fold In-Type RH (LH Opposite)
41 3/4"
3' 8" to 4'
X
11
Specified for hospital drive-through pharmacies
plus labs, supply rooms and other secure
interior areas, these windows can be equipped
with transaction drawers, bullet resistant
glass, a choice of counter tops and other
custom features.
Fully assembled for easy installation
Auto-close and reverse-on-contact functions
Maximum security locks
Sensor packages
SecurityWindowsAutomatic and manual systems
Setting The Standards For Professional Installation And Service
Horton Automatics brings you the professional support of factory-authorized distributors located throughout North
America. Whether your application involves a single automatic door or a complete hospital access and security plan,
you can expect all phases of the project to be handled professionally and responsively.
Call your Horton Automatics distributor today
for design, specification and and application
assistance. Visit www.hortondoors.com to find
the nearest distributor in your area.
Exterior view - automatic singleslide, flush mount shown
WinScan™ photoelectric beam HipScan™ activating system
Interior view with projectingpanels and roof
Auxiliary pushbuttonactivation
Specify Horton and demand AAADM certified installation.
Horton AutomaticsWorld Headquarters4242 Baldwin BoulevardCorpus Christi, Texas 78405-3399 USA
Phone: 800-531-3111, 361-888-5591Fax: 361-888-6510www.hortondoors.com
Horton Automatics, Ltd.United KingdomUnit A, Hortonwood 31Telford, Shropshire, England TF1-7YZ
Phone: 01952 670169Fax: 01952 670181
A Division ofOverhead Door CorporationA Sanwa Shutter Company Form No. HC1000 ©2007 Horton Automatics Printed in U.S.A.