Energy Efficient Elevators and Escalators and Regeneration

49
MSEE. Ibrahim GULESIN Pag. 1 a 49 The energy has become essential, but its high costs should motivate us to save wherever is possible. In particular, in Europe today there are nearly five million elevators and escalators, so 5 million of opportunities for action that could affect energy efficiency, energy recovery and the possibility of reducing the emission of carbon dioxide in the atmosphere (CO2) during the operation. It is therefore important to keep in mind that the less we consume, the less it pollution.

Transcript of Energy Efficient Elevators and Escalators and Regeneration

Page 1: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 1 a 49

The energy has become essential, but its high costs should motivate us to save wherever ispossible. In particular, in Europe today there are nearly five million elevators and escalators, so 5million of opportunities for action that could affect energy efficiency, energy recovery and thepossibility of reducing the emission of carbon dioxide in the atmosphere (CO2) during theoperation. It is therefore important to keep in mind that the less we consume, the less it pollution.

Page 2: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 2 a 49

Introduction....................................................................................................................................................... 3

Energy Transfer.................................................................................................................................................. 7

The method of Schroeder.................................................................................................................................. 9

The measurements of Doolard........................................................................................................................ 12

Calculating the power required to lift the load............................................................................................... 13

Energy consumption electric motor with inverter .......................................................................................... 15

Energy consumption for permanent magnet motor with inverter ................................................................. 15

Energy consumption for hydraulic drive ......................................................................................................... 18

The method of ISO........................................................................................................................................... 19

The electricity consumption of lifts in Europe................................................................................................. 28

Solutions for increased efficiency with the modernization of elevators .................................................... 28

General principles for achieving energy efficiency ..................................................................................... 28

Energy is consumed by the elevator and escalator mainly with:............................................................ 30

There are many factors that influence these losses to a system of elevator and escalators: .................... 30

Characteristics of equipment used.......................................................................................................... 30

The system configuration of lift / escalator. ........................................................................................... 30

The major producers of elevators What are you doing? ................................................................................ 31

SCHINDLER............................................................................................................................................... 31

KONE........................................................................................................................................................ 31

OTIS.......................................................................................................................................................... 32

ThyssenKrupp Elevator ............................................................................................................................ 32

Delbo S.P.A. ...........................................................................................Errore. Il segnalibro non è definito.

DB-Ecogen Energy from the sun to 'lift or escalator ............................................................................... 34

DB-Regen Energy Recovery ..................................................................................................................... 35

DB-StByGen standby energy production................................................................................................. 38

DB-6REGen Energy Recovery multiplex................................................................................................... 40

DB-SM-Gen Energy Recovery for escalators. .......................................................................................... 42

DB-Hydro-Gen Energy Recovery for hydraulic elevators ........................................................................ 44

Considerations for Energy Recovery Project ............................................................................................... 33

Conclusions and recommendations ............................................................................................................ 46

Bibliografia.................................................................................................................................................. 48

Page 3: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 3 a 49

IntroductionItaly is the European country that emits carbon dioxide into the atmosphere about 10 times higher than

Switzerland and much of that wasted energy that could easily be recovered for example, installing solar

panels for hot water, photovoltaic panels to produce electricity or thermal insulation in external walls androofs of buildings and produce elevators, high efficiency and low consumption or with energy recovery. It

can even have energy savings totally consumed in the building up to more than 50%. Considering that theless you consume, pollute less, if we want to respect the Kyoto protocol is necessary to implement

something concrete even in the elevator industry. Why, considering the table below:

COUNTRY No. of lifts installed (2010) No. of lifts sold annually (2010)

Spain 910.563 33.836

Italy 850.000 13.400

German 650.000 9.984

Turkiye 232.700 7.400

In Europa 4.752.233 116.226

There is already about 4,8 million lifts, as well as about 75 thousand escalators and moving walks installed in the

EU-27. Their energy consumption adds up to 3 to 5 % of the overall consumption of a building. About one third

of the final energy consumption in the European Community occurs in the tertiary and residential sector, mostly

in buildings. Due to the increasing comfort requirements, energy consumption in buildings recently experienced

a significant raise, being one of the leading reasons for a growing amount of CO2 emissions. High untapped

saving potentials exist with respect to energy-efficient equipment, investment decisions and behavioral

approaches, in these sectors.

Simulations indicate that on average a hydraulic lift at low load, running 100,000 starts a year, would use

1,900 kWh / year. On the other hand power consumption in standby can get a lift to 2 kW, which would

translate into 10,000 kWh / year for 5000 hours of standby time in a year. This represents a substantial

share of total annual electricity consumption of the elevator, which is between 25 and 80%.

The elevator systems have been designed individually for each specific application. Each of its parts

contribute differently to the overall efficiency of the lift. All elevator systems have common elements,

regardless of their principle of operation, including: a cabin, doors, lights and ventilation systems, a motor

and a control device (said control panel) with shaft,(an enclosed area where the car travels). There are two

main classes of systems: hydraulic lifts and electric traction. Electric traction can be further divided into two

categories: motor with gearbox (geared) and gearless.

The hydraulic elevators are typically have no counterweight, are the most inefficient and consumes an

amount of energy three times greater than an electric elevator. The energy is dissipated as heat when it

goes down. Hydraulic elevators traveling at low speeds, typically less than 1 m / s. The maximum stroke for

this type of plant is about 20 m. This is due to the fact that increasing the height of travel, the pistons of

larger diameter should be used to withstand the greater forces of instability. This increases the cost of the

equipment that makes the systems less attractive.

Page 4: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 4 a 49

The technological choice between the 2 types of lifts (hydraulic or electric) is based on a ratio of 3:1 ofdifference of energy consumed. Within the same category, the difference in energy consumed between themost efficient and least can get to 30-40%. Anyway, we must remember that at least two thirds of allsystems installed today are hydraulic elevator, however, limited to no more than seven stops, the rest arecalled elevators that use electric traction rope guided by pulleys driven by a motor and are fitted with acounterweight that reduces the weight to be lifted.

Dynamical systems are driven by motors with large rotating masses or used to move large loads of weight,

build up high levels of kinetic energy or potential energy and this means that when there is a slowdown or

shutdown may present a problem. Is thus required the motor to work in reverse and the motor behaves as

a generator of electrical energy that must be diverted or dissipated. An easy way to do this is to provide a

surplus of electricity to a resistor which converts it into thermal energy. Examples of systems that store

kinetic energy are centrifuges, press brakes, wind generators, large fans and trains, while examples of

potential energy sources are adapted elevators, escalators and cranes.

Between the drive systems of the motor of these lifts we can find DC motor with generator (MDC-G) that

has the lowest efficiency because of the large energy loss in the motor and the generator, which converts

electrical energy into mechanical energy and finally back into electrical energy. Another reason for the low

efficiency of the drive motor MDC-G is that the engine must be kept running when the elevator is idle.

Similarly, even AC motors to 1 or 2 speeds are considered less energy efficient. These motors usually one ortwo speeds, especially during acceleration and deceleration, consume electricity 4 or 6 times more thannormal which is dissipated as a result of overheating in the motor winding. The gearbox and flywheel iron /cast iron contributing to the low efficiency of the system.

These types of electric motors AC-1, AC-2 or VVVF are also used for escalators and moving walkways in sucha drive system (control panel) moves steps and handrails. Other elements that compose them are steps inaddition to the drive, sensors, brakes and chain. The escalators typically traveling at a speed of about 0.5 m/ s which is fast enough to provide a rapid shift without neglecting the comfort and safety. Escalators andmoving walkways are used especially in commercial centers, airports and metro and its drive system of theengine is running all the time regardless of the loading condition of the stairs or escalators. Thus theelectricity is continuously consumed even when there are no passengers on them. Much energy istherefore wasted if the number of passengers is widely fluctuating such as railway stations, commercialcenters and places like public transport and metro.

The hydraulic elevators dominate the market for buildings are not very high, because they have

substantially lower purchase prices. The market for buildings and buildings traditionally makes use of

elevators with electric motor (geared), while those without direct electric motor (gearless) are

predominant in high-rise buildings and skyscrapers. The oldest and least efficient elevators use electric

motors or induction as DC drive motor and electromechanical relays for control. Currently, the control

system with the relay has been abandoned and replaced with electronic control panels. Parallel to the

drive units for lifts to one or double speed, are giving way to the systems of compact motors with

permanent magnets and drive VVVF With PWM converter that will become an efficient use of equipment

with a braking system capable of regenerating electric energy .

Page 5: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 5 a 49

Fig.1. PWM Converter Fig.2. Control panel VVVF

A recent Canadian study on total energy consumption can be up to 3,000 GWh / year. There are about150,000 lifts in Switzerland who consume about 300 GWh, equivalent 0.5% of electricity needs of thecountry. The standby power lifts is about 160 GWh.

Technological development in the elevator industry was mainly driven by factors other than energyefficiency. Travel speed, acoustic noise, ride comfort and space are the main concerns of the lift design.However, the demand for energy efficient and greener buildings has increased in recent years and theelevator industry has responded accordingly, presenting its customers with solutions to meet thesegrowing needs.

The increase in electricity prices has also made an important contribution to the demand for more efficientenergy solutions. In most applications, electricity costs are often higher than the same cost of equipmentpurchased, which is why it is so convenient to invest in an elevator with high energy efficiency.The energy is used for efficient technological developments that take different approaches addressingseveral sources of inefficiency in vertical transportation systems. These causes can be divided into two maingroups: direct and indirect. The direct causes are those that can be directly connected to the device, whilethe underlying causes are related to the operation of the equipment. The most common direct causes are:frictional losses, transmission losses, motor losses and losses on the brake resistor and brake.

The energy consumption of an installation of an elevator is a significant percentage of the total electrical

load of the building. Estimates range from 5 to 15% depending on other services installed in the building.

The understanding of energy use and costs is becoming increasingly important for customers of this

industry. Therefore it is necessary to predict, with reasonable accuracy, the use of energy in a new

installation and modernization of already existing plants.

If the objective is to recognize the energy efficiency of the lifts, the most important consideration is that

they must be regarded as the best engineering systems, once installed the basic elements (cab

compartment) these will be used for the life of 'building (in many cases 30 to 100 years). However, during

this life of service, many factors that can affect energy consumption, they may still be replaced.

Spain is home to the world of elevators, followed by Italy and Germany. Italy is the country that has the

highest number of elevators, after Spain, which is about 850,000, the rate of growth and new facilities are

impressive. Install each year from 10,000 to 20,000.

Page 6: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 6 a 49

As we know, the life cycle of a plant is 10-30 years where it is undergoing major renovations that would

correspond to about 20.000-40.000/anno. On average, in Italy, there are approximately 50,000 new plants

and renovated facilities.

In Europe you have then about 5 million of opportunities for action on energy efficiency of elevator. Most

major manufacturers of elevators currently producing sytems can produce energy savings of 20-30%

compared to traditional systems, which Delbo SpA, the market offers systems that can produce energy

savings of 30% -80% with DB-EcoGen, DB-ReGen, and DB-6ReGen DB-HydroGen and 93% with DB-StByGen

standby applies to new installations or existing installations for all types of elevators, escalators and moving

walkways.

MSEE. Ibrahim GULESIN

Page 7: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 7 a 49

Energy TransferAn rope elevator, and counterweight, serves as a storage device for energy. In an ideal world without

friction losses, energy is never consumed in an elevator, is borrowed and then returned. Taking as an

example only of a building that houses offices, all passengers who take the elevator upward in the morning,

will resume in the afternoon to go down. The potential energy that has been "stored" in the morning it will

be returned to the system in the afternoon. The inefficiency of the system to cause the loss of energy. The

system of the lift substantially converts electrical energy into mechanical energy input in the output, with

losses in the form of heat. Taking a simplified diagram that represents the flow of energy in and out (see

Figure 3), there are three active phases in the flow of energy during acceleration, constant speed and

deceleration phase.

Fig.3 Diagram representing the Idea flow of energy use when the various phases of a journey of elevator

1. When the elevator is at rest before the trip, the only energy consumed is that necessary tomaintain the controller running.

2. Once the elevator starts to accelerate, the system absorbs energy to deliver kinetic energy to themasses in motion. It will also be consumed or returned, as in the following phase the potentialenergy.

3. At the end of the acceleration phase, the kinetic energy is no longer necessary because the velocityis constant. During the movement to the top: if the car is loaded with its load exceeds theacceleration phase to the constant speed and deceleration. The potential energy is required tomove the masses unbalanced while the kinetic energy is stored / dissipated in the masses in motion(the weight of the car and the weight of the counterweight).

4. The system is therefore designed to store potential energy. If the counterweight is heavier, thesystem returns potential energy. Similarly in the cars traveling to the bottom, the potential energycan be saved or restored.

Page 8: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 8 a 49

5. At the end of the constant speed, the elevator begins to slow down and is returned to the kineticenergy stored in moving masses. The potential energy will be drawn or returned as the final stage.From the moment the elevator stops at the floor, back to the first phase where the only energyconsumed is needed to keep the controller running (standby).

6. When the net energy required is negative, the unit will return regenerative energy in thedistribution network, or consumed as a heat engine or as a heating resistor.

Fig.4 Diagram representing the flow of real power during the different stages of a journey of elevator

1. When the elevator is at rest before the trip, the only energy consumed is that necessary tomaintain the controller running.

2. Once the elevator starts to accelerate, the system can absorb energy 3-6 times greater than therated current of the motor or pump (if Example. Current Rating = 10 Amps can be up to 60AmperPower = 26 kW and drops with oscillation in 2-3 seconds at the nominal current and power kW =7kW) to provide kinetic energy to the masses in motion. It will also be consumed or returned, as inthe following stage, the potential energy.

3. At the end of the acceleration phase, the kinetic energy is smaller but still useful because thevelocity is constant (depends on the type and installation of the installation and performance of themotor). During the run toward the cabin is high load and with its load exceeds the accelerationphase, that of constant speed and deceleration. Potential energy is required to move the massesunbalanced. The potential energy is required to move the masses unbalanced while the kineticenergy is stored / dissipated in the masses in motion (the weight of the car and the weight of thecounterweight).

4. The system is therefore designed to store potential energy. If the counterweight is heavier, thesystem returns potential energy. Similarly in the cars traveling to the bottom, the potential energycan be saved or restored.

5. At the end of the constant speed, the elevator begins to decelerate to slow down and is returned tothe kinetic energy stored in moving masses. The potential energy will be drawn or returned 3-4

Page 9: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 9 a 49

times more than the rated current of the motor or pump (if Example. Current Rating = 10 Amps canbe up to 40Amper Power = 18 kW with a drops down in 2-3 seconds at rated current Power =1,5kW as in the last phase. At the moment when the elevator stops at the floor, returns to the firstphase where the only power consumed is necessary to maintain the controller running.

6. When the net energy required is negative, the unit will return regenerative energy in thedistribution network, or consumed as a heat engine or as a heating resistor.

The method of SchroederSchroeder has developed a simple method to calculate the energy consumption and using a table of basicformulas. The table estimates the typical duration of a trip of a elevator according to the number of floorsof the building and the speed of the lift. Using the number of start movement per day, and assuming thatthe motor has been used at full capacity during execution, has made an estimate of daily energyconsumption of the elevator. Multiplying this by the number of days worked per year and then dividing bythe area the building, is the possibility of calculating a figure of merit for evaluating the energy consumedby the building's elevators per m2 per year. For the first time has taken the average for an engine rubricm% (see Table 1) He then proceeds to another factor - the typical time travel - TP, which depends on thenumber of floors of the building, the type of actuation and consequently the speed of year. Table 2 showsthe values calculated by Schroeder for several drives.

Tabella 1

azionamento piani edificio m%

Campo Media

OleodinamicoSenza contrappeso

3-4 22-28 25

Con riduttoreAC 2 velocità 4-8 37-50 44

ACVV(peso basso)6-12 29-33 31

ACVV(peso alto)6-12 21-23 27

Senza riduttore Motore- generatore12-18 17-25 21

Tiristori 12-18 12-21 17

Page 10: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 10 a 49

Tabella 2

azionamento piani edificio TP[sec.]

Campo Media

OleodinamicoSenza contrappeso Meno

di 65-7 6

Con riduttoreAC 2 velocità 6 9-12 10.5

ACVV(peso basso)12 7-10 8.5

ACVV(peso alto)12 5-8 6.5

Senza riduttoreMotore- Generatore 18 4-6 5

Tiristori 18 3-5 4

The factor TP is inserted into the following formula:

where:And - the daily energy consumption in kWh / dayR - motor power in kWST - the number of departures per dayThe parameter "ST" is to be esteemed or measured, which affects the accuracyof estimation.The value of "E" is used to calculate the annual energy consumption

Instead (e) per unit surface:

Example 1:A building is equipped with four elevators, each having the operating speed of 1.52 m / s, 10 passengersand a drive motor-generator. TP is the factor from the tables be 5 seconds (mean value). The power of anengine is 18.5 kW. To determine the daily energy consumption of the only parameter that is missing, andthat has to be estimated, is ST the number of departures per day. A simple method to estimate the numberof starts is consider two peaks of two hours each, during which we obtain the maximum value of 240times per hour. We consider then another eight hours of regular traffic of 40 departures per hour(so we considered 12 hours a day 7:00 to 19:00). We have as a result the number total starts a day:

Page 11: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 11 a 49

S = 2 × 240 + 2 × 240 + 8 × 40 = 1280 start per day

So the total consumption per day for each lift:

Eday=(18,5 x 1280 x 5) / 3600 =32,9 kWh/day per lift

For all four elevators: 32,9x4=131,6 kWh/day

The annual energy consumption for 269 days:

Eyear=131,6 x 269 =35407,5 kWh

emissions of carbon monoxide CO2=27618 kg/year

Estand-by = 4,7 x 24 x 365 = 41172 kWh/year

emissions of carbon monoxide CO2=23468 kg/year

annual cost: €.18.380

Considering 600 people in the building and 20 m2 for each person, you get:

eanno=131,6 x 269 x 0,85 / 600 x 20 =25,07 kWh/m2 year

Page 12: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 12 a 49

The measurements of DoolardDoolard has performed a large number of measurements on thirty elevator. He measured the energyconsumed by each lift when performing a round trip of three floors. The elevators were empty. The resultswere normalized with respect to the mass of the car and plotted with respect to the nominal speed. Initself, the measurements of Doolard were not a means to calculate the energy consumption of otherinstallations of lift, but a comparison indicative between the different types of lifts. CIBSE Guide D Systemstransport in buildings provides a method for the use of the results of Doolard so that the data can beapplied to other plants.

Of which is seen that hydraulic elevators consume the most energy of a rope type 2 speed and VVVF system

consumes less.

Page 13: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 13 a 49

Calculating the power required to lift the load

Fig.5

where:T = load to be lifted (traction difference in Kg) (The traction difference depends on the balance of the plantand by the weight of the ropes (in the absence of compensation ropes).V = speed of the car in m / s.ηa = Efficiency of the winch (0.6 to 0.75 with worms in 1 start, 0.8 to 0.9 with screws with no end in 2 or more active).Yield = ηv compartment (0.9 to traditional arcades, arches 0.8 per cantilever) ηp = Efficiency of pulleys (usually 0.98 each pulley). N = Number of sheavesχ = Safety factor for possible overload (typically 1.1).

Example: a plant capacity of 4 people with capacity 320 kg, speed 1.2 m / s, stroke 30 m, 3 ropes 10mmdiameter, without compensation ropes and 1 pulley;yields are ηa ηv = 0.8 = 0.9; ηp = 0.98.

Balance type:1) Balance at 50% The difference in shooting uphill climb at full load will be:

T = Capacity - (Range * 0.5) + Ropes Weight = 320 - 160 + (0.37 * 30 * 3) = 193 Kg

Page 14: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 14 a 49

The motor power required, using the formula written above, will be:

P = (1,1 x 193 x 1,2) / (0,8 x 0,9 x 0,98 x 1 x 102) = 3,6 kW

1) Balance 35%The difference in shooting uphill climb at full load will be:

T = Capacity - (Capacity * 0.35) + Ropes Weight = 320 to 112 +33.3 = 242 Kg

The motor power required will be in this case:

P = (1.1 x 1.2 x 242) / (0.8 x 0.9 x 0.98 x 1 x 102) = 4.44 kW

Page 15: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 15 a 49

Energy consumption electric motor with inverter

Fig,6

where:

E inv: energy consumption kWh/day

P : power of motor kW

ST : daily running with people

TP: travel time

Example: Motor power 4.4 kW, speed of the elevator 1m / s, running daily start 100, TP (door open+ door close + departure + arrival + time to travel + arrival + door open +door close) is 12 secondsfor 360 days

Einv = 0.52 x 4.4 x 100 x 12/3600 = 0.762 kWh / day

Eanno = 0.762 x 360 = 275 kWh / year

Page 16: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 16 a 49

Estand-by = 0.500 x 24 x 365 = 4380 kWh

Annual cost: 0.24 x 4655 = € .1117,00

Energy consumption for permanent magnet motor with inverter

Fig.7

Example: Engine power 2.8 kW, speed of the 1m / s, running daily 100, TP (departure gate closure + + +

Expected + stroke length door opening) is 6 seconds for 360 days

Einv = 0.3 x 2.8 x 100 x 6/3600 = 0.14 kWh / day

Eanno = 0.14 x 360 = 50.4 kWh / year 36% savings compared with traditional gear

Page 17: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 17 a 49

Estand-by = 0.500 x 24 x 365 = 4380 kWh

Annual cost: 0.24 x 4431 = € .1063,00

Page 18: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 18 a 49

Energy consumption for hydraulic drive

Fig.8

Example: motor power 15kW, del'impianto speed 1m / s, running daily 100, TP (departure gate closure + +

+ Expected + stroke length door opening) is 6 seconds for 360 days

Einv = 1.7 x 15 x 100 x 6/3600 = 4.25 kWh / day

Eanno = 4.25 x 360 = 1530 kWh / year

Estand-by = 0.500 x 24 x 365 = 4380 kWh

Annual cost: 0.24 x 5910 = € .1419,00

Page 19: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 19 a 49

The method of ISO

standards of energy consumption of elevators and calculated using the following formula:

where:E-Annual energy consumptionk2-compartment height factor (two levels: 1, other: 0.5)k1-average load factor (tension: 0.35; regenerative traction +: 0.21; hydraulic: 0.3)Pm - motor power [kW]v-speed lifthmax-height bayZ-number of cycles per year of racing

Example 2:A building had a hydraulic system, range 4 persons, motor power 11 kW, speed 1m / s, height of room 20mST the number of departures per day. A simple method to estimate the number of starts isconsider two peaks of two hours each, during which we obtain the maximum value of 50times per hour. We consider then another eight hours of normal traffic of 20 per hour starting(so we considered 12 hours a day 7:00 to 19:00), but another 10 from 19:00 to 00:00 starting time.We have as a result the total number of departures per day:ST = 2 x 50 + 2 x 50 + 8 x 20 + 5 x 10 = 410 startsNumber of cycles per year of racing:Z = 410 x 360 = 147,600 annual starting.Annual energy consumption:E = (147 600 x 0.3 x 0.5 x 20 x 11) / (1 x 3600) = 1353 kWh

Power stand-by;E = 1.5 x 24 x 365 = 13,140 kWh (which includes consumption of switchgear, relays, contactors, cab light,display, buttons ... etc..)Annual cost: 0.24 +0.24 x1353 x13140 = € .3478,4

Fig.9 consumption of energy and stand-by operating according to the number of cycles of runs

Page 20: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 20 a 49

Fig.10 Percentages of energy consumption stand-by mode based on the type of buildingIt may be noted that the energy consumption in standby generally vary between 20% and 85%

Fig.11 Amount of energy consumption of an elevator during the stand-by

1 - Electronic control panel2 - Display of plan3 - Buttons plan4 - booth Buttons5 - Network of photocells for the car door6 - Inverter7 - Cabin Lighting8 - Door Operator

Page 21: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 21 a 49

MethodologyFor the measurement of the energy consumption of the lifts and escalators audited, and to ensure therepeatability of the measurements throughout the campaign, a methodology was developed, based on thefollowing documents:

Draft International Standard ISO/DIS 25745-1 Energy Performance of Lifts and Escalators – Part 1:Energy Measurement and conformance, 2008 [1];

EN 60359:2002 Electrical and electronic measurement equipment - Expression of the performance[2];

Nipkow J. Elekrizitaetsverbrauch und Einspar-Potenziale bei Aufzuegen, Schlussbericht November2005, Im Auftrag des Bundesamtes fuer Energie [3];

Lindegger Urs, Energy estimation: Document for E4, ELA, VDI & ISO, 11 June 2008 [4];

Gharibaan Esfandiar, Load Factor for Escalators, EG (09/05/2008) [5].Only a brief description of the methodology is made in this report, to help readers understand the basicprocedures behind the measurements made. A detailed description of the methodology can be found onthe project’s website (www.e4project.eu).The aim of the measurements was to determine the direct energy consumption of the installation itself – inthe case of a lift this includes the direct electrical power consumption ofthe lift, but does not include additional equipment such as the machine room ventilation or shaft lighting.Thermal losses in buildings from shaft ventilation are also not part of the audits.

The electrical power demand of both the 3-phase power coupling for the drive circuit and the single phase

power coupling for the lift ancillary circuit were monitored. Figure 5-3 shows the measuring points used for

the German monitoring campaign. For some lifts it was not possible to differentiate between the twobranches of power supply, e.g. for reasons of accessibility; for these installations, the energy consumption

was measured before the splitting point (see Figure 5-1, Figure 5-3).

The methodology considers energy measurement relating to the normal operation of the lift, escalator and

moving walk including: Main energy - elevating/escalating/moving walk equipment such as: motor,

frequency converter, controls, brake and door.

Ancillary energy - car auxiliary equipment such as: light, fan, alarm system, etc. Other consumption such as

hoistway and machine room illumination, heating, ventilation and air conditioning were excluded from themeasurements.The reference measurement cycle for lifts, starting at the bottom landing, consists of:

Opening the Door

Closing the Door

Driving the car from the bottom landing to the top landing, without passengers

Opening the Door

Closing the Door

Driving the car from top landing to the bottom landing, without passengers

Opening the Door

Closing the Door

6 2

Page 22: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 22 a 49

The total running energy consumption per one cycle is calculated using the recorded values of

The total running energy consumption per one cycle is calculated using the recorded values ofactive power and time

The measurement of the standby energy consumption starts 5 minutes after the lastmovement of the car.Both values, running energy and standby energy, are combined with usage patterns toestimate the annual energy consumption, in kWh, of the installation.

Where,Elift Energy used by the lift in one year [kWh/year]caml Average motor load factor.catd Average travel distance factor (1; 0,5 or 0,3)h Rise height [m]ntrip Trips per year [1/year]Estandby Standby Energy used in 1 year [kWh/year]Ecycle Energy for a cycle trip [Wh]cbal Balancing factor

The annual standby energy used is calculated in the following way:

Where,Estandby Standby Energy used in 1 year [kWh/year]catd Average travel distance factor (1, 0.5 or 0.3)h Rise height [m]ntrip Trips per year [1/year]Pstandby Standby Power [W]v Speed of lift [m/s]All measurements are made with an empty car. Since lifts do not run empty all the time underreal conditions, adjustments via a typical load collective2 were done. The average motor loadfactor Caml, as shown in Table 5‐2 is used for this calculation.

Page 23: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 23 a 49

Fig.12 shows a typical cycle of an elevator traction. (source E4-WP6)

The initial transient, typical of a direct starting of an AC motor, it is evident. In this case, in the starting

phase in downward (empty car) the power active energy is 145% (7 times) more than the rated engine

power. This value can vary with the load and the balance of the system with the counterweight and during

the "trip down" is necessary to overcome the difference in weight between the car and counterweight.

When "travels up", as the counterweight is heavier than the cabin, the active power required is quite

reduced. Arrived at the end of each trip, there is a peak in the active power corresponding to the braking

power of the motorized system.

Page 24: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 24 a 49

Figure 13. Typical cycle of a hydraulic lift. (source E4-WP6)

When the elevator "travels down", the total active power required by the hydraulic lift system is practically

nothing compared to the consumption of standby. this small consumption is mainly due to the

maintenance of hydraulic fluid pressure because the descent valve allows the flow of hydraulic fluid to

move towards the tank. The real energy consumption high as the entire weight of the car must be raised,

requiring high electrical power and power as you move upwards as shown in the graph. The consumption

of the entire cycle of the lift stroke is highly dependent on the number of floors.

Page 25: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 25 a 49

Figure 14. Percentage of standby mode and race to the overall energy consumption of elevators in the

residential sector. (source E4-WP6)

It 'clear that the standby power lift is a very important issue. The stand-by consumption is between 4.2%

and 90.2% of the total consumption of the lift. It is important to note that among the models used has an

important influence the relationship between power and running in standby energy consumption of lifts

which is greater in the installation as a whole. The figure below illustrates the various states of operation of

a scale Mobile features a variable speed drive..

Page 26: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 26 a 49

Figure 15. Active power of an escalator in different operating modes (source E4-WP6)

Typically, three modes of operation are provided by a variable speed escalator. Determined period of

inactivity, these escalators reduce their speed and reach the so-called mode "reduced speed". The

consumption in this phase is more or less half of the consumption in the normal operation mode. After

reaching this mode of operation, and After another interval of time, the scale is put in a stop mode. At this

point, only the control system and the passenger detection system (pressure sensor on the stairs,

photocells or infrared rays), are kept running. When a passenger is detected, the escalator slowly begins to

move again, slowly speeding up to reach the rated speed. According to a methodology developed, the

standby consumption is considered to be the sum of the low speed and consumption in shutdown mode.

Page 27: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 27 a 49

Figure 16. Annual electricity consumption of escalators monitored (source E4-WP6)

Page 28: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 28 a 49

The electricity consumption of lifts in EuropeAccording to statistics of the equipment installed as part of Work Package 2 of project E4, there are

approximately 4.8 million elevators installed in the 19 countries surveyed. The data obtained through the

investigation of WP2, for 19 countries, were adjusted to EU-27 plus Switzerland and Norway. Using the

methodology previously described, the total electricity consumed by plants trucks is estimated at 18.4

TWh, of which 6.7 TWh in the residential sector, 10.9 TWh in the tertiary sector and only 810 GWh in the

industry.

Solutions for increased efficiency with the modernization of elevators

The efficiency of the engine has a significant effect on energy efficiency. The motors that can be used in

installations elevators are: DC motor with power factor 0.5 to 0.7, asynchronous motors with alternating

current power factor from 0.7 to 0.85 and synchronous motors with permanent magnets with power factor

0.85 -0.98. The DC motors have good control characteristics, however, are expensive and produce noise in

the power network and the efficiency of the engine is less than 60%. The asynchronous motors do not have

a good power factor (power factor) but the efficiency of the engine and less than 70%. Due to the

development of magnetic materials, modern elevators are starting to use the permanent magnet

synchronous motors of small size. Due to the low inertia, are easier to control, and have a very high power

factor and efficiency of the engine greater than 85%.

Technological development in the elevator industry was mainly driven by factors other than energy

efficiency. Travel speed, acoustic noise, ride comfort and space are the main concerns of the lift design.

However, the demand for energy efficient and greener buildings has increased in recent years and the

elevator industry has responded accordingly, presenting its customers with solutions to meet these

growing needs.

The increase in electricity prices has also made an important contribution to the demand for more efficient

energy solutions. In most applications, electricity costs are often higher than the same cost of equipment

purchased, which is why it is so convenient to invest in an elevator with high energy efficiency.

The energy is used for efficient technological developments that take different approaches addressing

several sources of inefficiency in vertical transportation systems. These causes can be divided into two main

groups: direct and indirect. The direct causes are those that can be directly connected to the device, while

the underlying causes are related to the operation of the equipment. The most common direct causes are:

frictional losses, transmission losses, motor losses, losses on the brake resistor and brake heat and heat

losses.

General principles for achieving energy efficiency

In general, the principles for the achievement of energy efficiency for plants lifts / escalators are the

following:

1. Define the equipment or device for energy efficiency.

2. Do not change the design of existing systems.

3. Place items in a suitable area.

4. Appropriate control and energy management of lifting equipment.

5. Use lightweight materials for the coating of the cab

6. Frequent maintenance for proper seal.

Page 29: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 29 a 49

As established above, one of the energy losses of the lifting equipment are the friction during its operation.

In modern installations of an elevator, various methods are employed to reduce the loss of these friction.

Some of these measures to be taken are:

1. The use of transmission gears with high efficiency to reduce the transmission loss.

2. The use of bearings for the shaft of the pulley.

3. The suspension of the car from a point above its center of gravity instead of the geometric center of the

crosspiece so as to reduce the lateral thrust on roller rubbing of the guide.

4. The use of roller guide shoes instead of skates rubbing.

5. The reduction in the number of pulleys. The smaller the pulley consequently less friction will result. If the

engine is mounted under (lower level), it is more efficient to locate the traction sheave in the hoistway to

have two additional pulleys to divert the ropes from the machine room in the hoistway.

6. The use of pulleys of large diameter. The greater will be ildiametro of the pulley, the lower the tensile

force required for the rope to overcome the moment of friction of the bearings.

7. The use of ropes and pulleys suitable plant itself to improve the performance of work.

The energy efficiency of hydraulic lifts

The hydraulic lift in itself is not fundamentally a machine with high efficiency

compared with an elevator rope. The energy is discharged in the following ways:

1. Energy loss in the motor (drive of the hydraulic pump) during the conversion of electrical energy into

kinetic energy.

2. Energy loss in the same hydraulic pump.

3. Energy loss in the valve assembly due to pressure drop.

4. Energy loss in the transmission of the hydraulic fluid.

5. The engine has no feature of regenerative energy.

6. Loss of energy, as the heat dissipation of the hydraulic fluid.

7. The system usually is not equipped with a counterweight to compensate for potential energy demand of

the cabin.

8. The pump always has a flow and a constant speed in spite of the various weight to lift. If the speed is

lower than the nominal speed (such as during acceleration and deceleration), part of the hydraulic fluid is

returned to the reservoir through by-pass. The loss is significant when the car accelerates and decelerates.

9. In some cases, extreme separate arrangements of cooling (for example cooling coils) are required to

avoid excessive heating of the hydraulic fluid.

10. With friction of moving parts like the cylinder, pads, leads, etc..

11. During acceleration and deceleration consumes electricity 4 or 6 times more than the nominal that is

dissipated as a result of overheating of the oil.

Factors that affect the consumption of energy in the system of elevators and

escalators

GeneralityThe mode of vertical transportation in buildings can be classified in three main ways:

1. Frequent use (traffic) on the scale

2. Frequent use (traffic) of the lift

3. Frequent use (traffic) of the escalator

Page 30: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 30 a 49

Each of these modes of vertical transport has its own characteristics and limitations. Despite the extensive

use of different lift, there are basically two main categories of lifting equipment, ie the electric and

hydraulic lift.

From the point of view of energy efficiency, the electric elevator rope has more energy efficient of the

hydraulic lifting system. Once installed the hydraulic lift, it uses a considerable amount of energy that is

wasted in heating the hydraulic fluid through hydraulic pressure. Some installations do not even have to

separate chillers to cool the fluid to prevent overheating. In addition, hydraulic elevators are not usually

provided with a counterweight, therefore, the lifting motor must be large enough to lift the rated load plus

the dead weight of the cab. Electric elevator, the maximum weight to be lifted under normal conditions is

only about half of its rated load. Therefore, designers must navigate the search materials and systems more

energy efficient systems for ascensoristici and escalators.

Energy is consumed by the elevator and escalator mainly with:1. Losses due to friction incurred during the trip.2. Dynamic damage losses during starting and stopping.3. The potential transfer of energy when moving uphill or downhill.4. Regenerative energy recovery, or the fuel system.5. The general approach to energy efficiency in air lifts and escalatorsonly to minimize frictional losses and losses of the system dynamics.

There are many factors that influence these losses to a system of elevator and

escalators:Characteristics of equipment used1. The type of control system (panel Maneuver) to operate the motor and the machine.2. Inner lining of the cab.3. Means for reducing friction in the moving parts (eg guide pads).4. The type of elevators and escalators.5. The speed of the elevator / escalator.6. The pulley apparatus.

Characteristics of local1. The distribution of local machines.2. The type of premises.3. The height of the premises.4. Type of structure that maintain the local machines.

The system configuration of lift / escalator.

1. The zoning of the lifting system.2. The combination of the components of elevators and escalators.3. The strategies for the vertical transport.4. The degree of service required of the system.

Page 31: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 31 a 49

The major producers of elevators What are doing?

SCHINDLER

The leader in elevators and escalators, today, thanks to the project Schindler energy. You can save on

energy costs by producing clean energy lift. The news was in Florence turned to condominiums, hotels and

businesses. It should be noted that the annual expenditure for the electricity consumed is greater than the

elevator to the annual fee for maintenance of the facility. In contrast, for those who adhere to the project,

will be sufficient to install photovoltaic solar panels that store energy from the sun, will transmit the

electricity grid. The lift will work thanks to this energy, clean and cost. Also, you will need to anticipate any

amount of money. The investment required for the supply and installation of solar photovoltaic panels can

be reimbursed through state subsidies, which encourage the production of clean energy. Specifically

Schindler is committed to implementing responsible use of resources, limiting the effect that the materials

purchased and delivered may have on the environment throughout their life cycle where possible and

replacing them with eco-friendly materials, to continue in all the locations saving energy, reducing CO2

emissions and electricity consumption.

KONE

It 'a technology used to convert mechanical energy into electrical energy when the elevator shaft acts as a

generator. When an empty car or a full salt down. The counterweight or the cab itself act as a motor and

the KONE EcoDisc becomes a generator. The regeneration system recovers energy and converts it into

electricity, which can be used for example to illuminate the building. You can convert up to 25% of the total

energy used by the elevator.

Economical operation with regeneration energy KONE: The elevators are moving within the compartment is

filled with that empty cabin. The energy consumption is higher when a full or empty car down salt. But

when a car goes full or empty room is higher than that generated energy consumption: it creates so the

braking energy. In systems with traction power is dissipated by braking resistors: the energy is converted

into heat and dissipates, often making it necessary to use more energy to cool or ventilate the space where

the braking resistors are placed. With KONE regenerative solutions for medium to low buildings, the

elevator converts this energy into electricity ready for reuse within the building. With the engine operating

as a generator, it converts the braking energy into electricity that can be used for other applications within

the building or to move other elevators. Electromagnetic interference and harmonic distortion are kept

well below the allowable values. The regenerated energy, with low harmonic distortion is clean. Up to 20%

of the total electricity used in the lift can be recovered. The result is a reduced net power consumption of

the building. You get so considerable savings during the life cycle.

Page 32: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 32 a 49

OTIS

Generating clean energy, so they shared empty elevator that goes up and down an elevator load?. An

amount of excess energy, which often is dissipated as heat. The drive ReGen converts this energy into

electricity and returns it to the electricity network of the building for reuse by other loads such as lighting.

It produces clean energy.

GeN2 Comfort can be equipped with the drive ReGen, a new technology efficient from the point of view of

energy that can provide savings of up to 75% compared to the conventional elevator systems. (hydraulic).

When the cabine is full capacity, used gravity to make the ride down, enabling the machine to produce

instead of consuming energy, just like a generator. The same occurs when a cabin empty or lightly loaded

makes its upward running, the counterweight is heavier and moves downward due to gravity, thus

generating energy. ReGen Drive, exclusive of OTIS, is able to use this energy and making it available to the

electrical network of the building, where it can be used to power other electrical components.

ThyssenKrupp Elevator

ThyssenKrupp Elevator has started since last March in Germany, the marketing of an elevator that takes

advantage of all the passive energy during deceleration or braking, reimmettendola in the circuit with a

recovery of 30% of electricity, although it is still premature to determine the date entry into the market, is

determined by its Italian division to launch this type of ecological lift in our country. And 'a' holding our

local ECO SUN POWER instead patent ERS (Energy retrive System). That is a system that can retrieve and

store the kinetic energy caused by the movement of ascent and descent of the elevator and use it to power

lights of stairs, door opening, intercoms and more as part of a building that functions electronically.

Page 33: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 33 a 49

Considerations for Energy Recovery Project

1. When a system is used in energy recovery must take special precautions to ensure that the quality

of the regenerated power is of sufficient quality to be accepted by the network and the network is

fully protected against short circuits and disorders.

2. The values of capacitance of the capacitors for the removal of harmonics must be carefully

calculated to make sure that together with the distribution transformer capacitors do not create a

resonant circuit.

3. The variable frequency drive type VVVF and hardware (electrical and electronic components), may

influence the choice of filter components and each of the following points must be taken into

consideration:

the type of modulation and the modulation factor of the drive

the switching frequency for the regeneration

the impedance of the drive and power supply

the length of cables

special characteristics of the drive (circuit to raise the voltage of the DC link)

E 'is also important to remember that the power distribution network may not always be free to accept

regenerated energy, due to unplanned power outages or other unforeseen problems. Thus, a braking

resistor will almost certainly be required for dynamic braking or reserve for emergency situations.

Page 34: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 34 a 49

DB-EcoGen Energy from the sun to lift or escalator

Fig.17 DB-EcoGen a typical photovoltaic generating system connected to the network of lifts

A solution for every situation: energy from the sun. The solar photovoltaic technology. This technology

enables the direct conversion of solar energy into electricity. The base unit is "the photovoltaic cell," which

consists of a small slab of semiconductor material (almost always silicon) that treated in the appropriate

way, creates the potential difference between the upper surface (-) and lower (+). The solar radiation that

hits the cell starts to move the electrons inside the material, which move from the negative to the positive.

This movement generates current. The cells are connected together and coated in a manner to form larger

surfaces of the said "modules". The photovoltaic modules in turn are connected to each other to form the

"Photovoltaic Generator", able to generate substantial electrical energy thus produced by the generator

Photovoltaic during the hours of the day must be accumulated before they can be used at night.

The photovoltaic systems are divided into two main categories according to the type of storage used

1. In photovoltaic systems where there is no electricity grid (remote rural, mountainous and inaccessible),

accumulation is done through the use of Batteries: PV-grid installations

2. In systems of cities and urban areas of the DC current is converted to AC (via an inverter) and then fed

into the grid. In this way the current can be taken at the time of need and is the same network that

functions as an accumulator: photovoltaic systems on the network. This type can be used to supply

elevators, escalators and moving walkways. You can save on energy costs of the lift through the production

of clean energy. The lift will work thanks to this energy, clean and zero cost.

Page 35: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 35 a 49

DB-ReGen Energy Recovery

Fig.18 DB-Regen a typical energy recovery system connected to the distribution network

The efficiency of the engine has a significant effect on energy efficiency. Electrical energy is consumeddirectly from the drive system (Control panel) and the motor. In this way the motor is able to convertelectrical energy into kinetic energy. The history of technological development has changed enough for theequipment of a lift especially the engines.Some of these engines were / are in the elevator system:

1. Motors with DC generator (MDC-G).2. DC motors with solid-state regulator (DC SS).3. 1 or 2 speed AC motors.4. AC motors with variable voltage regulator (ACVV).5. AC motors with variable frequency and voltage controller (ACVVVF).

Between the drive systems of the above, MDC-G has the lowest efficiency because of the large energy lossin the motor and generator, which converts electrical energy into mechanical energy and finally back intoelectrical energy. Another reason for the low efficiency of the drive motor MDC-G is that the engine mustbe kept running when the elevator is idle.

Page 36: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 36 a 49

Infrared picture of running electric motor (Source: Future Energy Solutions, 2009)

Similarly, even AC motors to 1 or 2 speeds are considered less energy efficient. These motors usually one ortwo speeds, especially during acceleration and deceleration, consume electricity 4 or 6 times more thannormal which is dissipated as a result of overheating in the motor winding. The gearbox and flywheel iron /cast iron contributing to the low efficiency of the system.Combining a certain type of engine and a certain type of control system can be obtained consistentreductions as concerning the energy consumption of the lift than the old hydraulic elevator. For example, arevolutionary solution consists in the use of the permanent magnet motor without a reduction gear(GEARLESS). This solution increases the energy efficiency of 40% over the traditional system with tractionand 60% compared to the hydraulic system.

Today, electricity is becoming an increasingly precious commodity and it is therefore essential that most ofthis energy can be recycled back into making the power source - a process known as recovery. However,braking resistors may still be required as a backup system when the power supply network is not able toreceive power recovered, as in the case of absence of current, voltage levels incompatible or situationscritical to safety.

With the introduction of new Community legislation such as the European Directive 2005/32/EC EuP (EcoDesign of Energy-using Products) is the responsibility of designers and manufacturers to ensure thatproducts are energy efficient.

Fig.19 a cycle of consumption of an elevator. Stored energy is recovered.

Page 37: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 37 a 49

DB- ReGen Regenerative and a converter (converter energy recovery) as shown in figura.14. Kinetic energy

stored in moving masses is recovered.

A more concrete example was done on an elevator system that has the following characteristics;

Elevator has capacity: 1200kg

Capacity: 16 people

Size: 2:1

Vana stroke: 45m

Motor: Permanent Magnet Wittur (Gearless)

Poles: 22,

Power: 17.6 kW,

Nominal Current = 43Amper,

Rpm = 153 rpm,

Sheave diameter: 400mm

In an hour moving the elevator consumes active power: 13.8 kW

Energy recovered during deceleration: 6.2 kW. This means 45% of energy is recovered.

Harmonics THD = 8.6%,

Power factor and efficiency = 0.97%

Total energy consumption of the lift in 8 hours: 110.4 kW,

Energy recovered in 8 hours = 49.6 kW

The annual energy cost recovered: 49.6 x 0.24 x 360 = €. 4285.44

Energy recovered in a year: 49.6 x 360 = 17.856kW

The annual cost of energy consumed: 110.4 x 360 x 0.24 = €. 9538.56

Total energy consumption per year = 110.4 x 360 = 39,744

Reducing CO2 emissions to the atmosphere, 17,856 kg x 0.57 = 10177kg/anno

DB-Regen as shown in figura.18 composed of four main components that are connected between the

mains and the converter, which is connected to the load, connected to AC1-2-speed induction motors or

synchronous motors (permanent magnets) in this case a asynchronous motor. A back-to-back inverter was

chosen to recover energy from the network. Connection to the public supply network via a standard EMC

filter for removing conducted disturbances, resistors which are connected to the precharge circuit when

the inverter is first put under tension, to reduce the peak current and protect the capacitors of the DC link

during the charge, filter for the removal of harmonic frequencies in the wave sinusoidal current when the

power is recovered from the load to the distribution network. BOOST separate reactor that raises the

voltage of the DC link, thus allowing current to flow to the distribution network.

Page 38: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 38 a 49

DB-StByGen standby energy production

Fig.20 DB-StByGen a typical power system operating under the lift and accessories

The developments in microelectronics technology have also started to be used in systems andcontrol panels for lifts was relay and contactor have been abandoned and replaced with electroniccontrol panel. The advantages derived from the electronic control system have made neglecting theincreased use of energy during the stand-by mode. With the start of the use of security systems ofthe doors and of variable speed drives, which have been developed in successive periods, togetherwith the illuminated buttons, display inside and outside of the cabin, warning systems and securityand other electronic equipment, the energy requirements during the stand-by are increased in orderto keep active all these systems.Elevator motors at one speed or double speed, which were intensively used in earlier periods, havegiven way to the VVVF drive systems. With MRL (machine room less) systems, the size of themotor reduced, with permanent magnet motors the traveling comfort is increased and reducedpower consumption by up to 50% compared to traditional traction elevators. This application is alsoused as an alternative energy-efficient. Although an additional power consumption with the inverteris wrong with the overall power consumption of elevators, drive units with inverters have beenpresented as an energy efficient solution for all .. These systems were then imposed on consumers

Page 39: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 39 a 49

as the only energy-efficient solutions regardless of the use of the lift. Then, a new marketingstrategy supported by a discourse on ecology impernianti increase in unit sales ascensoristicheinverter.It 'was supported in a study supported by the Swiss Agency for Energy Efficiency (SAFE) on 33different lifts, the amount of energy consumed by the elevators in stand-by has reached 80% of totalenergy consumption. SAFE in research, is also indicated that lifts a lot of the solutions used withhydraulic drives have the same energy efficiency of electric MRL. The same conclusion wasdeduced from Leeds in his MSc thesis. These results do not support a general conclusion, whichindicates that the hydraulic elevators consume more energy than the electrical MRL.In the study of Leeds also stipulates that lifts with low use, the use of inverters increases the powerconsumption during stand-by and then, the traditional hydraulic lifts are still a good choice. It wasalso noted that if an elevator is in standby mode for 80%, the inverter consumes an amount ofenergy equal to 222 kWh / year for a lift. This means that the poor use of elevators, energyconsumption would increase despite the use of newer technologies that aim ascensoristiche energyefficiency. Another similar example could be the hydraulic systems with accumulators. Althoughthese systems are not used frequently because of initial costs, it is indicated that the system wouldconsume more energy when these types of lifts are used continuously at low loads. The uses thataffect energy consumption in stand-by mode are shown in Fig. 20. As can be seen in the cabinlighting always on, and the sealing system of the doors indicates the maximum use. These arefollowed by the control panel (QDM) and the inverter.DB-StByGen produces electricity from solar panels and converts direct current into alternatingcurrent and at the same time charging the battery backup for use in the evening with a range ofminimum two hours. And with Intelligent Controller is totally off the power of the QDM (sleepmode). Just get a call or a door opening / closing operation by the photocell receives a wake-upsignal and the QDM rialimenta

DB-StByGen is a kit consisting of photovoltaic module No. 2, No. 2 backup battery, intelligentcontroller No. 1 and No. 1 converter that can power the panel maneuver with minimum 14 hoursautonomy. You can use any type of hydraulic elevator, electrical, MRL, escalators and movingwalkways. If an elevator consumes energy in standby 1.8 kWh a year would consume 1.8 x 24 x360 = 15,552 kWh and the building would pay in a year: 15,552 x 0.24 = € .3732,48DB-Usandosi StByGen saves the cost of energy consumed in standby and reduces CO2 emissionsto the atmosphere every year 15,552 kg x 0.57 = 8864.64kg/anno

Page 40: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 40 a 49

DB-6REGen Energy Recovery multiplex

Fig.21 DB-6REGen a typical energy recovery system multiplex parallel connections DC Link

DB-6REGen is another way to recover electrical energy can be used with the multi drive systems. The

parallel connection of the DC link of several drives can power a PWM converter, the engine of which is used

in traction for braking energy / regenerated from another drive. This increases the efficiency of the system

since not all the energy recovered is wasted as heat generated by the braking resistors and less energy is

drawn from the mains. This can be particularly beneficial if you are using the facilities for Duplex, Triplex, ...

Sesduplex. Many DC bus systems are used in applications in high performance servo drives where

substantial amounts of energy are used in acceleration and braking from the drives.

• The group of varistor for surge protection provides input phase-phase and phase to earth.

• The use of a converter input bulk is preferred if the installation requires that all drives are connected to

different power.

• A high voltage capacitor polypropylene should be inserted between the terminals of the rectifier module

because this helps to reduce the peak inverse voltage switching and can also provide a way to RFI noise

currents in applications where there are long cable runs.

• The inductance of the DC link of standard drives tend to be down when the drive is powered with DC

voltage and then you need an external inductance value suitable for all drives connected to the DC link.

• By dividing equally the inductance between the positive and the negative line of the DC link, can provide

some impedance to limit fault currents if you see a ground fault in the line in the positive or negative line of

the DC link.

• The inductance of the DC link should be chosen with a value such as to maintain constant in a reasonable

time constant of the DC link.

Page 41: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 41 a 49

• The DC bus is connected to all inverters.

• The limitation of the inrush current is not required if each drive has its own soft start circuit (limiting

resistor and relay / contact) as a function until the DC link voltage reaches the correct level.

• Can be still necessary to have a resistor braking requirements for fail-safe.

Page 42: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 42 a 49

DB-SM-Gen Energy Recovery for escalators.

Fig.22 DB-SM-Gen a typical energy recovery system for escalators

These types of electric motors AC-1, AC-2 or VVVF are also used for escalators and moving walkways in such

a drive system (control panel) moves steps and handrails. Other elements that compose them are steps in

addition to the drive, sensors, brakes and chain. The escalators typically traveling at a speed of about 0.5 m

/ s which is fast enough to provide a rapid shift without neglecting the comfort and safety. Escalators and

moving walkways are used especially in malls, airports and metro and its drive system of the engine is

running all the time regardless of the loading condition of the stairs or escalators. Thus the electricity is

continuously consumed even when there are no passengers on them. Much energy is therefore wasted if

the number of passengers is widely fluctuating such as railway stations, shopping malls and places like

public transport and meter.

How you can save or recover energy supply if an escalator is in works continuously even when there are no

Page 43: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 43 a 49

passengers on them?

First of all if the escalator is 1 or 2 AC motor speed must be controlled by a control panel with VVVF. Energy

can be saved if the motor speed can be adjusted according to the frequency of transport of passengers.

This can be achieved technically through the use of scanning sensors or photocells to barriers for the

control of passengers and Intelligent controller that manages the inverter to adjust the speed of the engine.

The slow speed is simply to indicate that the escalator is operating. Once the passengers jump a boarding

area, the speed of the ladder before it resumes to normal passengers actually board a vessel of the

escalator or moving walks. With intelligent controller adjusting the speed of the escalator with the

frequency of passengers can achieve energy savings of 30%. If a drive is powered AC1-2 is used a VVVF

inverter and you can reach savings of up to 45%.

The recovery of energy from an escalator is via the transformation of electrical energy into potential

energy. When passengers are transported from one level lower than the motor acts as a generator and the

excess energy can be converted into heat using dynamic braking resistors or can be fed into the public

electricity distribution, which of course is more satisfactory if the additional costs of a more sophisticated

drive system can be justified by the application.

With DB-SM-Gen recovers energy as a function of the input from the escalator and into a network. The

power of the control panel is made directly from the DB-StByGen.

DB-StByGen produces electricity from solar panels and converted from direct current to alternating current

is guaranteed at least 14 hours autonomy with intelligent controller that manages to be a function of both

an escalator and energy conservation. And with Intelligent Power Controller is totally off the QDM (control

panel), as soon as a signal come from a sensor or photocell gives power to the system this way saves 69% of

energy from an escalator.

Page 44: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 44 a 49

DB-Hydro-Gen Energy Recovery for hydraulic elevators.

Fig.23 DB-Hydro-Gen a typical energy recovery system for hydraulic lifts

Hydraulic elevators typically do not have a counterweight, are the most inefficient, sometimes consume

three times more energy for electric lifts. The energy is dissipated as heat when it goes downhill. Hydraulic

lifts travel at low speeds, typically less than 1 m / s. The maximum stroke for this type of plant is about 20

m. This is due to the fact that with increasing height of travel, of larger diameter pistons must be used to

withstand the greater forces of instability. This increases the cost of equipment and facilities makes

hydraulic use a less attractive choice. In addition to the low initial cost, the hydraulic elevators have some

advantages compared to cable systems, namely:

• The installation is very simple and fast.

• The space occupied by the equipment, as controls (control panel), motor (pump) is small and, therefore,

the engine room becomes useless. These parts are usually located in low cost areas of the building, such as

basements or under the stairs.

• The unit does not have conventional hydraulic counterweights, allows a closer race in vain. The absence

of counterweights also decreases the load on the building structure.

• The load is transferred to the ground and not to the building structure that results in lower manufacturing

Page 45: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 45 a 49

requirements and costs.

• Emergency procedures in hydraulic systems are relatively simple. The machine can be lowered by means

of a manually operated valve of an emergency. Similarly, a hand pump can be used to lift the machine in

case of power failure or breakdown of control.

Some of the disadvantages of conventional hydraulic elevators are:

• High consumption of energy as the entire weight of the car must be raised.

• Request high electrical power and power when moving uphill

• the number of starts times are limited and the operation speed is slow.

• Since the changes of viscosity of the oil are changed with the temperature increase or decrease with its

sometimes necessary to maintain quality and performance of the oil deveno be heated or cooled.

With DB-Hydro-Gen you can save the total energy consumed in standby and the power of the panel in

operation of the maneuver.

Example: 11 kW engine power, speed del'impianto 1m / s, running daily 150, TP (departure gate closure + +

+ Expected + stroke length door opening) is 9 seconds, for 360 days

E = 1.7 x 11 x 150 x 9/3600 = 7.05 kWh / day

Eanno = 7.05 x 360 = 2524.5 kWh / year

Estand-by = 1.6 x 24 x 360 = 13,824 kWh / year CO2 emission = 7879.68kg/anno

Etot = 16348 kWh / year

Annual cost Standby: 0.24 x 13824 = € .3317,70

A total annual energy savings with DB-Hydro-Gen is 85% and saving money of € annal .3317,70

Page 46: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 46 a 49

Conclusions and recommendationsThere are currently over 4,8 million lifts installed in the EU‐27 and, each year, another 115 thousand units are placed into service. Lifts are responsible for the consumption of 18 TWh ofelectricity which corresponds to 0,7% of the total European electricity consumption. In addition, there are approximately 75 thousand escalator and moving walks units installed in the EU27 with about 3.500 newunits installed each year.The monitoring campaign carried out during the project covered 81 installations throughout Europe: 74 liftsand 7 escalators. The main goal of this monitoring campaign was to create a data basis to make valid estim

ations of the energy consumed by lifts and escalators. For this purpose a monitoring methodology was developed based on previous work carried out by international standardisation bodies and otherrelevant institutions.The monitoring results highlighted the relative importance of standby consumption, which in some installations can be as high as 90% of the overall lift electricity consumption. The proportion of standby to overall consumption is greatly influenced by the usage pattern. This explains the fact that the estimated proportion of standby to overall electricity consumption of lifts in the residential sector is dominant (68%),whereas in the tertiary sector it represents 41%.This usage patterns also helps to explain the following effects: Lifts in the residential sector, although being

the majority of lifts installed (64% of units), are responsible for only 35% or 7 TWh of the electricityconsumed. Lifts installed in the tertiary sector with a more intensive use, consume about 11 TWh ofelectricity annually, which corresponds to about 1.5 % of the electricity consumed in that sector.

A technological assessment was carried out aiming at the characterisation of the existingtechnologies, as well as the identification of emerging energy efficient solutions which can provide electricity savingsboth in standby and in running of lifts and escalators. The most important keytechnologies identified include the following:

Premium efficiency induction motors or Super Premium efficiency permanent magnet synchronousmotors;

Efficient pumps in hydraulic elevators

Efficient drives with regeneration capability in buildings with intensive lift use;

Efficient transmission and roping;

Traffic management directed not only at efficacy when transporting passengers, butalso at energy efficiency

Low standby power components such as door operators, lamps, ventilators and displays

The technology assessment performance indicators, combined with the results from a market survey determining the main characteristics of the installed stock and of the monitoring campaign, were used toprovide a credible baseline for the evaluation of potential energy savings.Using the best available technologies would produce savings in the standby consumption of over 70%. In particular, energy efficient lighting options and the use of electronic components with low standby power (e.g. controllers and inverter) were found to play a major role in this reduction. Turning off non‐essential equipment or putting it into a very low power “sleep” mode, whenever possible, would produce even larger electricity savings.The potential overall (running plus standby) savings are estimated to be of 11 TWh,considering thatthe Best Available Technologies are used, or up to 13 TWh if technologies that are being developed but not yet widely used in the lift industry are applied. These savings translate into a reduction of carbon emissions of around 4,9 Mtons of CO2eq and 5,8 Mtons of CO2eq , respectively, considering the current electricity production mix in Europe.Concerning escalators our analyses came to the following results: The ability to adjustautomatically the speed of the escalator to the passenger demand is a solution that canproduce energy savings. The results of the monitored installations showed that escalatorsoperating in “reduced speed” mode consume approximately half of the electricity consumed innormal operation mode.

Page 47: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 47 a 49

The estimated electricity consumption of escalators in Europe is relatively modest (900 GWh),and a potential reduction of around 250 GWh (30%) could be feasible if all the escalatorsinstalled would be equipped with automatic speed controls and with low power standbymodes.However, before these potentials can be realized some barriers in the market need to beovercome that are present in the market today. In a further step, the most significant barrierswere identified, as well as possible strategies and measures to overcome those barriers. The main barriersidentified are:

lack of information and awareness of the actual electricity consumption of lift andescalator systems;

lack of information and awareness of the energy efficient technologies in the market;

low state of knowledge on the economic efficiency of the technological measures;

split incentives between general contractors, owners of installations as well as thosepaying for the energy consumption of installations .

These main barriers may be addressed by a combination of the following strategies:

Raising awareness through campaigns and the provision of information material for relevantstakeholder groups, such as the main dissemination materials (available online at www.e4project.eu) developed in this project:

a) “Options to improve lift energy efficiency”b) “Energy Efficient Elevators and Escalators – Technology Assessment”c) “Barriers to and strategies for promoting energy‐efficient lift and escalator technologies”d) “Guidelines for new lift installations and retrofitting”e) “Public Buildings Procurement Guidelines for Lifts and Escalators”National energy agencies can play a major role to improve awareness towards theselection and proper operation of energy‐efficient lift and escalator systems. ‐Implementation of a harmonized standard for measuring and predicting the electricity consumption for lifts and escalators, based on the previous international work and onthe methodology developed in this project.

‐Inclusion of lifts and escalators into a future revised version of the EPBD Directive, providing an incentive to use energy efficient technologies both in new buildings andin retrofits.‐Implementation of energy labels similar to those already in use in some European countries, providing easily accessible and understandable information, for buyers andspecifiers of lifts and escalators systems to support decision making processes‐Minimum energy performance indicators to be defined in close cooperation with lift and escalator manufacturers (e.g. maximum standby consumption for all systems, andmaximum specific consumption for non‐residential high traffic installations).

Page 48: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 48 a 49

Bibliografia

1. Braslavsky I. About the possibilities of energy saving under using controlled-velocityelectric drive.- Electrichestvo. 1998. №8 2-6 p. (rus)

2. Averbach I., Braslavsky I., Ishmatov Z., Barats E. I., Electric drive and automation ofindustrial plants as means of energy saving. Ekaterinburg: Sverdlovenergonadzor, 2002.(rus)

3. Braslavsky I., Ishmatov Z., Plotnikov Y. About efficiency of using frequency-controlledelectric drive in hosting gear applications. // Problems of automation drives. Theory andpractice. Herald NTU«Charkovsky polytechnic university». Output. 10, part. 1. Charkov,2003, с. 144-147. (rus)

4. Al-Sharif, L., Peters R. and Smith, R: “Elevator Energy Simulation Model”, IAEE, ElevatorTechnology 14, April 2004.

5. Al-Sharif , L: ”Lift and Escalator Energy Consumption”, Section 13: CIBSE Guide D,Transportation Systems in Buildings (The Chartered Institution of Building ServicesEngineers)(2000) ISBN 1 903287 09 X

6. Doolard D: “A Energy Consumption of different types of lift drive system ElevatorTechnology Proceedings of ELEVCON 1992” (The International Association of ElevatorEngineers) (1992)

7. Schroeder J: “The Energy Consumption of Elevators Elevator Technology 1”,(Chichester:Ellis Horwood) (1986)

8. Siikonen M : “On Traffic Planning Methodology Elevator Technology 10, Proceedings ofELEVCON 2000” (The International Association of Elevator Engineers) (2000)

9. Nipkow: “Elektriztastverbrauch und Einspar-Potenziale bea Aufzugen”. S.A.F.E.,2005,Zurich.

10. G. Lees: “A study of the actual power relative to the theoretical power consumption of avariable frequency drive hydraulic system and how it benefit the user”, master dissertation,University College Northampton, April, 2005

11. DRAFT INTERNATIONAL STANDARD ISO/DIS 25745‐ “Energy Performance of Lifts and Escalators – Part 1: Energy Measurement and conformance”, 2008

12. EN 60359:2002 “Electrical and electronic measurement equipment ‐ Expression of the performance”, 2002

13. Lindegger ,Urs: “Energy estimation: Document for E4, ELA, VDI & ISO”, 11 June 200814. Gharibaan, Esfandiar: “Load Factor for Escalators”, EG, May 200815. Dispan, J. (2006). Aufzüge und Fahrtreppen - eine Branche im Wandel. IG Metall.16. Sachs, Harvey M. (2005): Opportunities for Elevator Energy Efficiency Improvements

. ACEEE Available online at www.aceee.org/buildings/coml_equp/elevators.pdf.17. BrzozaBrzezina, Krzysztof (2008): Methodology of energy measurement and estimatio

n of annual energy consumption of lifts (elevators), escalators and moving walks. Project report of the E4 project.

18. Nipkow, Jürg (2005): Elektrizitätsverbrauch und Einspar‐Potenziale bei Aufzügen. Bundesamt für Energie Schweiz. Available online at: http://www.bfe.admin.ch/php/modules/enet/streamfile.php?file=000000008982.pdf&name=000000250057.pdf.

19. Barney, Gina (2007): 50 things you can do to make lifts energy efficient. Availableonline at www.cibseliftsgroup.org/CIBSE/papers/Barney‐onenergy%20efficiency%20of%20lifts.pdf.

20. Beier, Carsten (2009): Analyse des Energieverbrauchs und exemplarische Best‐practiceLösungenfür relevante Verbrauchssektoren in Krankenhäusern. Abschlussbericht.Fraunhofer UMSICHT. Available online at: http://www.umsicht.fhg.de/publikationen/stu

dien/EnEff_KH_Az_23472_Abschlussbericht_Download.pdf.

Page 49: Energy Efficient Elevators and Escalators and Regeneration

MSEE. Ibrahim GULESIN Pag. 49 a 49

21. European Commission (ed.) (2009): Reference Document on Best Available Techniques forEnergy Efficiency. Available online at http://ftp.jrc.es/eippcb/doc/ene_fd_0308.pdf.

22. Report with the results of the monitoring campaign. Project report D3.2 of the E4 project. (2010). Report of January 2010.

23. L’ascensore scende o sale? Servizio Centrale Studi Economici ANIE, 200824. Istituto Nazionale di Statisitica (ISTAT), Italian Census, 200125. Tecnoborsa, Italian families and real estate market26. ANCE - Confindustria. Survey on the construction sector, 200827. Technical Data – Electricity, TERNA, 200928. Climate Change Policies and Measures – Italian Greenhouse Inventory 1990-2006 –

National29. Inventory Report 2008, APAT Agency for Environmental Protection and Technical Services30. Agency for efficient energy use S.A.F.E., HTW Chur University of Applied Sciences, 2006