ENCAP SYSTEMS INC.
“Encapsulating and
Protecting building systems
for a stronger tomorrow”
ENCAP SYSTEMS OVERVIEW
ENCAP Systems Corporation is a manufacturer and
contractor specializing in lead paint abatement. ENCAP
offers a proven solution to lead based paint problems, with
several successfully completed encapsulation projects.
Several million square feet of lead based paint has been
encapsulated with Encap products. ENCAP Systems
Corporation has been in the hazardous remediation and
lead paint abatement industry since January, 1988, and has
successfully completed numerous projects ranging in size
from $500,000 to $2,000,000.
WHO IS ENCAP SYSTEMS
COMPANY HISTORY
In 1987, Roy E. Johnson was the founder of a system to encapsulate lead based
paint. The system is now being used for the rehabilitation of old buildings and as a
replacement for stucco in new construction. In 1988, Roy formed Encap Systems
Corporation, to market the product to the Federal Government and also to public
housing for the encapsulation of lead based paint.
Roy was successful in bidding the First lead based paint demonstration that was
conducted by Dewberry and Davis, mandated by the US Congress, as one of the
sixteen abatement contractors chosen from one hundred and twenty five other
larger companies. Encap System Corporation, under Mr. Johnson’s
management, became the only contractor/ manufacturer/ minority firm that was a
part of this exclusive work.
Roy was a member of the Army Corp of Engineers, the Chamber of Commerce and
the Urban Business Professional Association, Roy was a committee member of the
National institute of Building Science, where he helped develop the Guide
Specifications for reducing lead based paint hazards and the lead based paint
operations and maintenance work practice manual. He also served on the
committee EO 6.23, of the Association of Standard Testing Methods (ASTM) where
he helped develop standards for the testing procedures for lead encapsulation
materials. Roy assisted in developing the State laws for lead abatement workers
and contractors for the State of Ohio. Roy served on the State Lead Advisory
Committee in Ohio.
INDUSTRY QUANDARIES
WATER INTRUSION THROUGH:
CRACKED STUCCO/BRICK/
CONCRETE WALLS
ROOFING COVERING MATERIALS
ELEVATED SLABS
BASEMENT WALLS
MULTI FAMILY, COMMERCIAL &
RESIDENDTIAL STRUCTURES
COMPETITIVE ADVANTAGES
Only Cementitious based coating system in the US
approved by the Health Departments and the EPA
in all 50 States, as a safe product to be used around
children.
More durable and cost effective than traditional
stucco and other wall applications
Moisture resistant and allows for breathability
Extensive positive track record and testimonials
Moisture curing capabilities
Easy application process
Eight standard colors
Extreme adhesion and compaction strength
4500psi
Past Performance
Dewberry & Davis Study
Andros Island Navy Sub
Base
Patuxten Naval Air Station
Ohio Adjutant general Army
New Haven Court House
Authority
Oakland Housing Authority
Patrick Air Force Base
Veteran’s Hoapital-
Oakland,CA
Veteran’s Hospital- Vieira, FL
Veterans Hospital, Orlando, FL
F.D.O.T
Tyndall Air Base
Greater Orlando Aviation
Authority
Orlando Expressway Authority
Virgin Islands Port Authority/
Marine & Air
Federal Emergency
Management Agency
Homestead Air Base
Ft. Myer, Arlington, VA
Orlando Utilities Commission,
Orlando FL
Past Performance Con’t
Arlington Cemetary, MD
Housing Authority, Oakland,
CA
Housing Authority, New
Jersey
Housing Authority, Chicago
Housing Authority, Sanford, FL
Housing Authority, Fort Wayne,
ID
Army Base, Fort Dix
Potential Projects
• Enviro Tubes
• Gabion Baskets
EnviroTubes
The Encap Systems, Inc.
Potential customer:
ARMY CORPS of Engineers
EnviroTubes
Enviro-Tubes currently
deployed, shoreline protection and
wetland re-nourishment systems.
Currently for Enviro-Tube protection, we
are the only manufacturer of a coating
system that “significantly” adherers to the
petroleum based Bag Fabric.
ENCAP has been recommended for use
on both shore line protection systems, the
Enviro tubes.
Enviro Tube damage by hurricane force
winds in Galveston, TX
Shore Line Tubes damaged by
hurricanes
Severe damage where the tube protection
was missing
Gabion Baskets
The Encap Systems, Inc.
U.S. ARMY CORPS OF
ENGINEERS (USACE)
Flood protection used as Sea Wall
• Used in New Orleans as a buffer for Sea
Walls to keep them upright during high
winds and waves during storms.
Gabion basket filled with
sand. UV from the sun will
deteriorate the fabric
within 2 years causing the
basket to fail. ENCAP
SEAL will prevent fabric
failure.
This is the area where the
leavy walls were knocked
over by the storms.
Test for adhesion of
ENCAP SEAL to the
fabric and metal
frame.
Finished Project
Examples of Past Performance
Structure Wall
Repair
The Encap Systems, Inc.
Window opening created
Insulation placed in
opening. Plywood cut to
size with glass Fabric
affixed.
ENCAP product applied with
fabric imbedded. Then
sponged to texture matching
existing wall.
Brick lines etched
into the ENCAP
SEAL matching the
existing block before
painting.
Finished project prior to painting.
BRICK RESTORATION/
ENCAPSULATION
Bethune Cookman College,
Dayton Beach, FL
The Encap Systems, Inc.
Wall prepared
prior to applying
ENCAP SEAL.
Total building coated
with ENCAP SEAL
forming a water
resistant coat.
Etching brick façade after
applying ENCAP product in
a color matching the
previous brick.
BEFORE AFTER
Finished project
ENCAP SEALWater Intrusion Test
ASTM 1601
The Encap Systems, Inc.
Water Intrusion in Central
Florida Homes During Hurricane Jeanne in September 2004
ENCAP SEAL VA hospital water intrusion
prevention project
Prepared by:
Dr. Mike Mullens, PE
Dr. Bob Hoekstra
Isabelina Nahmens
Felix Martinez
UCF Housing Constructability Lab
August 2006
Test Equipment and Procedure
ASTM C1601 - 04 Standard Test Method for Field
Determination of Water Penetration of Masonry
Wall Surfaces (ASTM C1601 - 04 2004) is a
pressurized water test that simulates wind
driven rain. The test measures the rate of water
flow out of a closed system under a given rate of
air pressure and water flow that simulates wind
speed and rainfall rate respectively.
Used by the University of Central Florida to determine the
reasons for water penetrations, new and old stucco
construction during heaving rains and hurricanes.
Application of
water intrusion
equipment
being installed to
the walls of the
VA hospital prior
to the application
of the ENCAP
SEAL System.
Water curtain
attached to the
wall of the VA
hospital prior to
the application
of the ENCAP
SEAL water
proofing
system.
Note water running down the wall
prior to the application of the
ENCAP SEAL system.
UCF pump equipment
Test Results For Masonry Walls
as defined by ASTM C1601
Results after ASTM Test on
ENCAP SEAL on the walls at the
VA hospital..083 Gallons/ hour intrusion
(.375 Gallons/ hour intrusion considered
excellent)
The Encap Systems, Inc.
Asbestos
&
Lead
The Encap Systems, Inc.
Historical
Renovation/PreservationLead Abatement/Encapsulation
• Preserves a historical building’s
appearance while abating the lead base
paint or asbestos wall cladding
Historical Renovation/Preservation
Lead abatement/
encapsulation with
the ENCAP Systems
products preserved a
historical building
appearance while
abating the lead base
paint and asbestos
wall cladding.
Lead
Paint
This is an example of paint that must
be removed prior to the application of
the ENCAP Lead abatement
encapsulation system. The balance is
left to be encapsulated by the product.
Before Lead Paint
Encapsulation
After with ENCAP Seal
encapsulated using a hopper
spray gun in order to preserve the
historical features.
EXAMPLES OF PRODUCT USE
WATER PROOFING ON WALLS AND ROOFSOUC
Water Storage Tank,
Lake Highland
Orlando, FL
Encap Seal was applied as
a roof coating this water
Tank.
As a water proof
coating on concrete /
stucco walls
Allowing heavy
lift crane to
traverse
without damage to
The coating.
INSULATED WALL PANELS
ENCAP SEAL applied to walls, Orlando
Florida
SYSTEM OVER T1-11 WOOD
SIDING AND OLD BRICK
Columbus, Ohio
CONCRETE STRUCTURAL
REPAIRS
Retaining walls repaired without the use of concrete
forms.
Shell Oil Company , Cleveland Ohio
DENSE GLASS
ENCAP SEAL applied to Dense Glass without
using a vapor barrier.
Tavares, Florida
PRODUCT SPECS
Designed to encapsulate lead
based paint.
Environmentally friendly
Encapsulates some forms of
asbestos
Adheres to most sub-straits
Encap Seal achieves maximum
strength of 4500 PSI in 28 days
NAICS CODES:
236115, 236117, 236220,
237310, 238350, 238990, 238110, 238140,
238310,
238340, 238910, 321114, 337110, 321911,
332323,
541310, 541320, 561790, 561730, 541620,
562910.
COMPETITIVE ADVANTAGESComparison Study of Landing and Patio water proofing systems
Products/ properties SONOGUARD VULKEM 350/351 ENCAP SEALProduct base/ make up Polyurethane/paint Polyurethane/paint Cementitious/mortar
Bonds to smooth surfaces no no Extremely well
Level of surface prep required extensive extensive- moderate minor
Water proofer yes yes yes
Allows for water vapor release no no yes
Available colors standard/limited standard/limited standard/unlimited
Installed applications 3 parts 2 parts 1 part
Tensile strength/ASTM C-780/D-412 752 320
530 PSI w/o fabric. W/
fabric exceeds 2500psi
Compressive strengths N/A 2200psi 4500psi
Adhesion/ peal strengths 275psi 30psi 406 psi
Color application topical applied through-out through-out
slip resistance topical applied sand topical applied sand product finish & texture
Moisture curing yes no yes
bridging limitations 1/16" max 1/16" max
1/2" or < w/o mesh
1/2" or> w/ mesh
Packaging/ coverage 50-80 sqft/gallon 40 & 100 sqft/gallon 40sqft/50lb bag
application thickness 25/25/20 wet mills 40 & 15 wet mills 1/8"-1/4" min.
abrasion resistance ASTM D-4060 1000 cycles 1000 cycles exceeds 1000 cycles
Weatherization/ UV exposure N/A N/A Impervious
Warranty N/A on product only 5 years L&M
Application Risks
Combustible liquid and
Vapor
Combustible liquid and
Vapor none
Requires maintenance agreement for
warranty Yes n/a No
Can be Pressure washed No No Yes
damaged by sharp objects, sand, gravel
metal yes yes no
Storage/shelf life 1 year/with proper storage n/a Unlimited w/proper storage
Clean up Reducer 990 or xylene Reducer 990 or xylene water
Manufacturers: BASF® Tremko, Industries The Encap Systems, Inc.
The Chemical company
ENCAPS Total System
50 lbs. Bag ENCAP SEAL Powder
450sqft Roll Glass Mesh
5 Gallon Pail ENCAP Bond
(5 gals. Mixes approximately 4.5 - 50 lb. Bags)
ENCAP SYSTEMS, INC.
CEO: Roy Johnson
President: Steve Bishop
www.encapsystems.com