Electronic Overload Relays - ABB Ltd · Cost savings The wide setting range and integrated tripping...

6
ABB Electronic Overload Relays New complete range up to 1250A New

Transcript of Electronic Overload Relays - ABB Ltd · Cost savings The wide setting range and integrated tripping...

ABB

Electronic Overload Relays

New complete range up to 1250A

New

■ Up to 1000V and temperature range from -25 … +70 °C■ Acc. to IEC/EN 60 947-4-1 and UL508■ Tripping classes 10, 20, 30■ ATEX / Ex-approved

■ Low-energy consumption■ Direct mounting to ABB contactors■ Separate mounting kits available■ Independent from ambient temperature ■ Wide setting range

Electronic overload relays…

…are environmental friendly ■ Low power consumption saves energy ■ Materials employed can be recycled

…are safe and fl exible■ Better accuracy ■ Digital evaluation■ Less variants

…save costs■ smaller cabinets due to less heat dissipation■ less inventory

Electronic overload relays from ABB A complete range from 0,1A …1250A

E16DU E45DU E80DU E140DU E200DU

E200DUE140DU

E80DU E45DU

E16DU

10 20 30 40 50 60 70 80 90 100 120 140 160

Motor Starter Combinations – Overview

Cost savings

✔ The wide setting range and integrated tripping classes 10, 20, 30 substantially reduce the number of different types. This is a major benefi t for planning, project implementation, inventory and logistics.

✔ The low power consumption saves energy costs

✔ The low level of heat dissipation reduces cost of cooling or ventilation

✔ Temperature compensation of -25 to +70 °C prevents nuisance shut-down in response to changes in temperature and assures high precision and reliability

Technical Features

✔ No external power supply needed✔ Low energy consumption✔ Low heat dissipation✔ Wide setting range✔ Wide temperature range from -25 … +70 °C✔ High safety standard✔ Stable and precise trip curve throughout the entire life cycle✔ Fast phase failure detection✔ Test functions✔ Manual and automatic reset✔ Stop button

Time

Ie (adjusted current)

No Tripping at 1.05 IeTripping at 1.2 Ie within 2 hours

Class 10 4 - 10 sec

1.2 Ie 7.2 Ie

Class 20 6 - 20 sec

Class 30 9 - 30 sec

E320DU E500DU E800DU E1250DU

E1250DUE800DU

E500DUE320DU

180 200 250 300 400 500 600 700 800 900 1000 1100 1250 [A]

Electronic Overload Relays class 10, 20, 30

Type Setting range Trip Class Order Code Contactor Designation

Type Description Order Code

Trip Class 10, 20, 30 selectable

E16DU 0.32 0.1 - 0.32A selectable 1SAX 111 001 R1101 B...6-B...7 / A...9...A...16...

E16DU 1.0 0.3 - 1.0A selectable 1SAX 111 001 R1102 B...6-B...7 / A...9...A...16...

E16DU 2.7 0.8 - 2.7A selectable 1SAX 111 001 R1103 B...6-B...7 / A...9...A...16...

E16DU 6.3 1.9 - 6.3A selectable 1SAX 111 001 R1104 B...6-B...7 / A...9...A...16...

E16DU 18.9 5.7 - 18.9A selectable 1SAX 111 001 R1105 B...6-B...7 / A...9...A...16...

E45DU 30 9 - 30A selectable 1SAX 211 001 R1101 A...26 ... A...40

E45DU 45 15 - 45A selectable 1SAX 211 001 R1102 A...26 ... A...40

E80DU 80 27 - 80A selectable 1SAX 311 001 R1101 A...50 ... A...75

E140DU 140 50 - 140A selectable 1SAX 321 001 R1101 A...95 ... A...110

E200DU 200 60 - 200A selectable 1SAX 511 001 R1101 A...145 ... A...185

E320DU 320 100 - 320A selectable 1SAX 521 001 R1101 A...210 ... A...300

E500DU 500 150 - 500A selectable 1SAX 711 001 R1101 A...400 ... A...460

E800DU 800 250 - 800A selectable 1SAX 811 001 R1101 A...580 ... A...750

E1250DU 375 - 1250A selectable 1SFA 739 001 R1000 A...1350 ... A...1630

Accessories

DB16E separate mounting kit 1SAX 101 110 R0001

DB45E separate mounting kit 1SAX 201 110 R1001

DB80E separate mounting kit 1SAX 301 110 R1001

DB140E separate mounting kit 1SAX 301 110 R1002

DT500/AF460L Busbar Kit for AF400, 460YD, revers. 1SAX 701 902 R1001

DT500/AF460S Busbar Kit for AF400, 460DOL 1SAX 701 902 R1011

DT800/AF750L Busbar Kit for AF580, 750YD, revers. 1SAX 801 902 R1001

DT800/AF750S Busbar Kit for AF580, 750DOL 1SAX 801 902 R1011

LT200E Terminal shrouds for E200DU 1SAX 501 904 R0001

LT320E Terminal shrouds for E320DU 1SAX 601 904 R0001

LT500E Terminal shrouds for E500DU 1SAX 701 904 R0001

LT800E Terminal shrouds for E800DU 1SAX 801 904 R0001

ABB has always been committed to the issue of protecting motors. After all, any overload to a motor used in an industrial plant can give rise to production downtime and repair work, all of which drive costs up to a level many times the expense of investing in reliable overload and motor protection.

Electronic overload relays protect the motor from:■ overload■ phase unbalance■ phase failure

Reliable motor protection

An electronic overload relay has advantages compared to a conventional thermal overload relay in a wider range of settings and temperatures and a higher accuracy. In addition, electronic relays can be used in standard motors and for heavy-duty start-ups. A complete range of electronic overload relays from 0,1A to 1250A with tripping classes 10,20 and 30 is available. Up from construction size E45DU the tripping classes 10, 20 or 30 can be selected directly on the device.

ATEX certifi cates are available for protection of motors in explosion areas.

These electronic overload relays are cost-effective – simply because you only need a few units to cover a wide measuring range. This delivers user benefi ts in terms of planning, inventory and service.

Another major advantage is the low power consumption, something which has a noticeable impact on energy costs and the cost of housings and cooling provisions.

Bro

chur

e N

o. 2

CD

C 1

07 0

12 B

0202

P

rinte

d in

the

Fede

ral R

epub

lic o

f Ger

man

y

(

11/0

7 •

3 •

GV

D)

ABBABB Global Contact Directory

The ABB Contact Directory (http://www.abb.com/contacts/) helps you fi nd local contacts for ABB products in your country. Please select the relevant product group from the dropdown menu to the right or from the page.

ABB STOTZ-KONTAKT GmbHP. O. Box 10 16 80D-69006 HeidelbergTelephone: ++49 62 21 / 701-0Telefax: ++49 62 21 / 701-729http://www.abb.de/stotzkontakt

Universal motor controller0.16 – 850ATripping classes 5, 10, 20, 30Integrated inputs/outputsMotor control and diagnostic functionsField bus connection

Thermal overload relays 0.1 – 310A Tripping classes 10, 20, 30

Electronic overload relays0.1 – 1250ATripping classes 10, 20, 30

Manual Motor Starters 0.1 – 100A Tripping classes 10, 20 Integrated short circuit protection

Motor Protection from ABB