Electromagnetic flowmeterf02.s.alicdn.com/kf/HTB1G0hoFVXXXXafXXXX.PRXFXXX0.pdf · Electromagnetic...
Transcript of Electromagnetic flowmeterf02.s.alicdn.com/kf/HTB1G0hoFVXXXXafXXXX.PRXFXXX0.pdf · Electromagnetic...
KAFLON M&C INSTRUMENTS
Electromagnetic flowmeterKFL-DC SERIALSStandard Model> Local display> 4-20mA output> Pulse output> Flange Connection> Lining: CR (DN65 - DN 500) F46 (DN6 - DN 50)> Electrode: 316L SS> Working pressure: 1.6MPa> Accuracy: 1%R; 0.5%R(Opt.)> Working temperature: <60C
Thread Connection Model
> Local display> 4-20mA output> Pulse output> Thread Connection> Lining: F46 (DN6 - DN 50)> Electrode: 316L SS> Working pressure: 1.6MPa> Accuracy: 1%R; 0.5%R(Opt.)> Working temperature: <120C
Batch Control Model> Local display> Contact output> Pulse output> Flange or Thread Connection > Lining: F46 (DN6 - DN 50)> Electrode: 316L SS> Working pressure: 1.6MPa> Accuracy: 0.5%R> Working temperature: <120C
Process Control Model
> Low cost> No local display> 4-20 mA output> Flange or Thread Connection > Lining: CR (DN40 - DN 500)> Electrode: 316L SS> Working pressure: 1.6MPa> Accuracy: 1.0%R> Working temperature: <60C
KFL-DCT SERIALS
KFL-DCB SERIALS
KFL-DCP SERIALS
KFL-DCT SERIALS
> Local display> 4-20mA output> Flange Connection> Lining: F46 (DN6 - DN 100)> Electrode: 316L SS> Working pressure: 2.5MPa - 42MPa> Accuracy: 1%R; 0.5%R(Opt.)> Working temperature: <60C
KFL-DCW SERIALS
> Local display> Flange or Thread Connection> Lining: CR (DN50 - DN 300) F46 (DN6 - DN 50)> Electrode: 316L SS> Working pressure: 1.6MPa> Accuracy: 1%R; 0.5%R(Opt.)> Working temperature: <60C
High Pressure Model Battery Supply Model
KAFLON M&C INSTRUMENTS
Electromagnetic flowmeter Battery supply serials
KFL-DCW-D SERIALSRemote Type> Local display> Battery supply> Without output> Length of wire: <10m> Life of battery: 3 years> Accuracy: 1.0%R, 0.5%R
Integral Type
> Local display> Installed with sensor> Battery supply> Accuracy: 1.0%R; 0.5%R(Opt.)> Working temperature: -20C-50C> Protection class: IP68
Battery Supply with GPRS Model> Local display> Battery supply> Communication: GPRS, SMS> Accuracy: 1.0%R, 0.5%R> Life of Battery: 3 years> Working temperature: -20C-120C> Protection Class: IP68
KFL-DCW-M SERIALS
KFL-DCWS SERIALS
KFL-DCWS SERIALS
> Local display> Battery supply> Communication: GPRS, SMS> Accuracy: 1.0%R, 0.5%R> Life of Battery: 3 years> Working temperature: -20C-120C> Protection Class: IP68
Battery Supply with GPRS Model
Zhiyang zhu, Mobile: 0086-13567771170, Email: [email protected] KAFLON
KAFLON M&C INSTRUMENTS
Magnetic vortex flowmeterKFL-CD SERIALSStandard Model> Battery supply or 24VDC supply> 4-20mA output (Optional)> Pulse output (Optional)> Flange Connection> Electrode: 316L SS> Working pressure: (1.6-42)MPa> Accuracy: 1%R> Working temperature: <60C
Welding Connection Model
> Battery supply or 24VDC supply> 4-20mA output (Optional)> Pulse output (Optional)> Welding Connection > Electrode: 316L SS> Working pressure: 1.6MPa> Accuracy: 1%R> Working temperature: <60C
High Temperature Model> Battery supply> Thread Connection > DN6 - DN 50 mm> Electrode: 316L SS> Working pressure: (2.5-35)MPa> Accuracy: 1.0%R> Working temperature: <120C
Vortex Model
> 24VDC supply> Measuring medium: liquids, gas> 4-20 mA output> Flange Connection > Electrode: 316L SS> Working pressure: 1.6MPa> Accuracy: 1.0%R> Working temperature: <60C
KFL-CDH SERIALS
KFL-CDT-G SERIALS
KFL-CDV SERIALS
KFL-CDT SERIALS
> Battery supply or 24VDC supply> Measuring medium: conductive liquids> 4-20mA output (Optional)> Pulse output (Optional)> Thread Connection > Electrode: 316L SS> Working pressure: 2.5 MPa> Accuracy: 1%R> Working temperature: <60C
KFL-CDJ SERIALS
> Battery supply>Measuting medium: conductive liquids> Underside inlet, horizontal outlet> Easy maintenance> Less investment> Flange Connection> Electrode: 316L SS> Working pressure: (1.6-42) MPa> Accuracy: 1%R> Working temperature: <60C
Thread Connection Model Vertical Model (DN20-DN100mm)
FLow automatic controller
KFL-CDK SERIALS
> 220VAC supply> Measuring medium: conductive liquids> Less manpower> Automatic control flow rate > 4-20 mA output (24VDC)> Flange Connection > Electrode: 316L SS> Working pressure: (1.6-25) MPa> Accuracy: 1.0%R> Working temperature: <60C
KAFLON M&C INSTRUMENTS
Turbine flowmeterKFL-LWGY SERIALSStandard Model> Battery supply supply> Flange Connection> Working pressure: (1.6-4)MPa> Accuracy: 1%R> Working temperature: <60C
Local display with 4-20mA output
> Battery supply or 24VDC supply> 4-20mA output (24VDC)> Working pressure: (1.6-4) MPa> Accuracy: 1%R> Working temperature: <60C
Pulse output Model> 5-24VDC supply> Thread Connection > DN6 - DN 40 mm> Pulse output> Body material: 304SS> Working pressure: (1.6-42)MPa> Accuracy: 1.0%R
Pulse output Model
> 5-24VDC supply> Measuring medium: liquids, gas> Pulse output> Flange Connection >Body material:304SS> Working pressure: (1.6-4) MPa> Accuracy: 1.0%R> Working temperature: <60C
KFL- LWGB SERIALS
KFL-LWGP SERIALS
KFL-LWGP SERIALS
KFL-LWGY SERIALS
> Battery supply or 24VDC supply> 4-20mA output (Optional)> Pulse output (Optional)> Thread Connection > Body material: 304SS> Working pressure: 2.5 MPa> Accuracy: 1%R> Working temperature: <60C
Thread Connection Model
Turbine flowmeter
> Supply: 24VDC, Battery supply> Flow range: 0.04 to 800 m3/h> Accuracy: 1.0% R> Signal output: Pulse, 4-20mA> Connection: Flange, Thread > Body material: 304SS> Working pressure: (1.6-42) MPa
Technical Specifications
Contact us:WENZHOU KAFLON M&C INSTRUMENTS CO., LTD.Address: No.1-1, Dongchuan Road, Yueqing, Zhejiang, ChinaTel: +86-(0)577- 62566951Fax:+86-(0)577- 62569171Website: http://www.kaflon.com.cn http://kflux.en.alibaba.comEmail: [email protected]