6
KAFLON M&C INSTRUMENTS Electromagnetic flowmeter KFL-DC SERIALS Standard Model > Local display > 4-20mA output > Pulse output > Flange Connection > Lining: CR (DN65 - DN 500) F46 (DN6 - DN 50) > Electrode: 316L SS > Working pressure: 1.6MPa > Accuracy: 1%R; 0.5%R(Opt.) > Working temperature: <60C Thread Connection Model > Local display > 4-20mA output > Pulse output > Thread Connection > Lining: F46 (DN6 - DN 50) > Electrode: 316L SS > Working pressure: 1.6MPa > Accuracy: 1%R; 0.5%R(Opt.) > Working temperature: <120C Batch Control Model > Local display > Contact output > Pulse output > Flange or Thread Connection > Lining: F46 (DN6 - DN 50) > Electrode: 316L SS > Working pressure: 1.6MPa > Accuracy: 0.5%R > Working temperature: <120C Process Control Model > Low cost > No local display > 4-20 mA output > Flange or Thread Connection > Lining: CR (DN40 - DN 500) > Electrode: 316L SS > Working pressure: 1.6MPa > Accuracy: 1.0%R > Working temperature: <60C KFL-DCT SERIALS KFL-DCB SERIALS KFL-DCP SERIALS KFL-DCT SERIALS > Local display > 4-20mA output > Flange Connection > Lining: F46 (DN6 - DN 100) > Electrode: 316L SS > Working pressure: 2.5MPa - 42MPa > Accuracy: 1%R; 0.5%R(Opt.) > Working temperature: <60C KFL-DCW SERIALS > Local display > Flange or Thread Connection > Lining: CR (DN50 - DN 300) F46 (DN6 - DN 50) > Electrode: 316L SS > Working pressure: 1.6MPa > Accuracy: 1%R; 0.5%R(Opt.) > Working temperature: <60C High Pressure Model Battery Supply Model

Transcript of Electromagnetic flowmeterf02.s.alicdn.com/kf/HTB1G0hoFVXXXXafXXXX.PRXFXXX0.pdf · Electromagnetic...

Page 1: Electromagnetic flowmeterf02.s.alicdn.com/kf/HTB1G0hoFVXXXXafXXXX.PRXFXXX0.pdf · Electromagnetic flowmeter KFL-DC SERIALS Standard Model > Local display > 4-20mA output >

KAFLON M&C INSTRUMENTS

Electromagnetic flowmeterKFL-DC SERIALSStandard Model> Local display> 4-20mA output> Pulse output> Flange Connection> Lining: CR (DN65 - DN 500) F46 (DN6 - DN 50)> Electrode: 316L SS> Working pressure: 1.6MPa> Accuracy: 1%R; 0.5%R(Opt.)> Working temperature: <60C

Thread Connection Model

> Local display> 4-20mA output> Pulse output> Thread Connection> Lining: F46 (DN6 - DN 50)> Electrode: 316L SS> Working pressure: 1.6MPa> Accuracy: 1%R; 0.5%R(Opt.)> Working temperature: <120C

Batch Control Model> Local display> Contact output> Pulse output> Flange or Thread Connection > Lining: F46 (DN6 - DN 50)> Electrode: 316L SS> Working pressure: 1.6MPa> Accuracy: 0.5%R> Working temperature: <120C

Process Control Model

> Low cost> No local display> 4-20 mA output> Flange or Thread Connection > Lining: CR (DN40 - DN 500)> Electrode: 316L SS> Working pressure: 1.6MPa> Accuracy: 1.0%R> Working temperature: <60C

KFL-DCT SERIALS

KFL-DCB SERIALS

KFL-DCP SERIALS

KFL-DCT SERIALS

> Local display> 4-20mA output> Flange Connection> Lining: F46 (DN6 - DN 100)> Electrode: 316L SS> Working pressure: 2.5MPa - 42MPa> Accuracy: 1%R; 0.5%R(Opt.)> Working temperature: <60C

KFL-DCW SERIALS

> Local display> Flange or Thread Connection> Lining: CR (DN50 - DN 300) F46 (DN6 - DN 50)> Electrode: 316L SS> Working pressure: 1.6MPa> Accuracy: 1%R; 0.5%R(Opt.)> Working temperature: <60C

High Pressure Model Battery Supply Model

Page 2: Electromagnetic flowmeterf02.s.alicdn.com/kf/HTB1G0hoFVXXXXafXXXX.PRXFXXX0.pdf · Electromagnetic flowmeter KFL-DC SERIALS Standard Model > Local display > 4-20mA output >

KAFLON M&C INSTRUMENTS

Electromagnetic flowmeter Battery supply serials

KFL-DCW-D SERIALSRemote Type> Local display> Battery supply> Without output> Length of wire: <10m> Life of battery: 3 years> Accuracy: 1.0%R, 0.5%R

Integral Type

> Local display> Installed with sensor> Battery supply> Accuracy: 1.0%R; 0.5%R(Opt.)> Working temperature: -20C-50C> Protection class: IP68

Battery Supply with GPRS Model> Local display> Battery supply> Communication: GPRS, SMS> Accuracy: 1.0%R, 0.5%R> Life of Battery: 3 years> Working temperature: -20C-120C> Protection Class: IP68

KFL-DCW-M SERIALS

KFL-DCWS SERIALS

KFL-DCWS SERIALS

> Local display> Battery supply> Communication: GPRS, SMS> Accuracy: 1.0%R, 0.5%R> Life of Battery: 3 years> Working temperature: -20C-120C> Protection Class: IP68

Battery Supply with GPRS Model

Zhiyang zhu, Mobile: 0086-13567771170, Email: [email protected] KAFLON

Page 3: Electromagnetic flowmeterf02.s.alicdn.com/kf/HTB1G0hoFVXXXXafXXXX.PRXFXXX0.pdf · Electromagnetic flowmeter KFL-DC SERIALS Standard Model > Local display > 4-20mA output >
Page 4: Electromagnetic flowmeterf02.s.alicdn.com/kf/HTB1G0hoFVXXXXafXXXX.PRXFXXX0.pdf · Electromagnetic flowmeter KFL-DC SERIALS Standard Model > Local display > 4-20mA output >
Page 5: Electromagnetic flowmeterf02.s.alicdn.com/kf/HTB1G0hoFVXXXXafXXXX.PRXFXXX0.pdf · Electromagnetic flowmeter KFL-DC SERIALS Standard Model > Local display > 4-20mA output >

KAFLON M&C INSTRUMENTS

Magnetic vortex flowmeterKFL-CD SERIALSStandard Model> Battery supply or 24VDC supply> 4-20mA output (Optional)> Pulse output (Optional)> Flange Connection> Electrode: 316L SS> Working pressure: (1.6-42)MPa> Accuracy: 1%R> Working temperature: <60C

Welding Connection Model

> Battery supply or 24VDC supply> 4-20mA output (Optional)> Pulse output (Optional)> Welding Connection > Electrode: 316L SS> Working pressure: 1.6MPa> Accuracy: 1%R> Working temperature: <60C

High Temperature Model> Battery supply> Thread Connection > DN6 - DN 50 mm> Electrode: 316L SS> Working pressure: (2.5-35)MPa> Accuracy: 1.0%R> Working temperature: <120C

Vortex Model

> 24VDC supply> Measuring medium: liquids, gas> 4-20 mA output> Flange Connection > Electrode: 316L SS> Working pressure: 1.6MPa> Accuracy: 1.0%R> Working temperature: <60C

KFL-CDH SERIALS

KFL-CDT-G SERIALS

KFL-CDV SERIALS

KFL-CDT SERIALS

> Battery supply or 24VDC supply> Measuring medium: conductive liquids> 4-20mA output (Optional)> Pulse output (Optional)> Thread Connection > Electrode: 316L SS> Working pressure: 2.5 MPa> Accuracy: 1%R> Working temperature: <60C

KFL-CDJ SERIALS

> Battery supply>Measuting medium: conductive liquids> Underside inlet, horizontal outlet> Easy maintenance> Less investment> Flange Connection> Electrode: 316L SS> Working pressure: (1.6-42) MPa> Accuracy: 1%R> Working temperature: <60C

Thread Connection Model Vertical Model (DN20-DN100mm)

FLow automatic controller

KFL-CDK SERIALS

> 220VAC supply> Measuring medium: conductive liquids> Less manpower> Automatic control flow rate > 4-20 mA output (24VDC)> Flange Connection > Electrode: 316L SS> Working pressure: (1.6-25) MPa> Accuracy: 1.0%R> Working temperature: <60C

Page 6: Electromagnetic flowmeterf02.s.alicdn.com/kf/HTB1G0hoFVXXXXafXXXX.PRXFXXX0.pdf · Electromagnetic flowmeter KFL-DC SERIALS Standard Model > Local display > 4-20mA output >

KAFLON M&C INSTRUMENTS

Turbine flowmeterKFL-LWGY SERIALSStandard Model> Battery supply supply> Flange Connection> Working pressure: (1.6-4)MPa> Accuracy: 1%R> Working temperature: <60C

Local display with 4-20mA output

> Battery supply or 24VDC supply> 4-20mA output (24VDC)> Working pressure: (1.6-4) MPa> Accuracy: 1%R> Working temperature: <60C

Pulse output Model> 5-24VDC supply> Thread Connection > DN6 - DN 40 mm> Pulse output> Body material: 304SS> Working pressure: (1.6-42)MPa> Accuracy: 1.0%R

Pulse output Model

> 5-24VDC supply> Measuring medium: liquids, gas> Pulse output> Flange Connection >Body material:304SS> Working pressure: (1.6-4) MPa> Accuracy: 1.0%R> Working temperature: <60C

KFL- LWGB SERIALS

KFL-LWGP SERIALS

KFL-LWGP SERIALS

KFL-LWGY SERIALS

> Battery supply or 24VDC supply> 4-20mA output (Optional)> Pulse output (Optional)> Thread Connection > Body material: 304SS> Working pressure: 2.5 MPa> Accuracy: 1%R> Working temperature: <60C

Thread Connection Model

Turbine flowmeter

> Supply: 24VDC, Battery supply> Flow range: 0.04 to 800 m3/h> Accuracy: 1.0% R> Signal output: Pulse, 4-20mA> Connection: Flange, Thread > Body material: 304SS> Working pressure: (1.6-42) MPa

Technical Specifications