ECUE-XX-XXX-XX-XX-XX-1-XX-MKT - Samtec...

6
THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN, MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC, INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS WRITTEN CONSENT OF SAMTEC, INC. PROPRIETARY NOTE * * THIS PRODUCT MANUFACTURED WITH LEAD-FREE PROCESSING Pb C C NOT TOOLED * NOT TOOLED * DO NOT SCALE FROM THIS PRINT * DESIGNED & DIMENSIONED IN MILLIMETERS[INCHES] No OF PAIRS END 2 OPTION ASSEMBLY LENGTH SHIELDED CABLE TYPE OPTION WIRING OPTION (SEE TABLE 1) -1 -12 (T1 & C1 CABLE ONLY) -08 (T2 CABLE ONLY) 007 - 999 cm (SEE NOTE 8) -C1: TCF-3850 (38AWG COAX,12 PAIRS ONLY) -T1: TTF-36100 (36AWG TWINAX,12 PAIRS ONLY) -T2: TTF-34100 (34AWG TWINAX, 8 PAIRS ONLY) -FF: ECUE -EC: ECDP -01 "A1 TO A19" -02 "A1 TO B1" -B4 (8 PAIR ONLY) "A1 TO B19" (LOW PROFILE) BLANK: STANDARD FIREFLY -D1: DECOUPLING CAPACITORS (SEE NOTE 7) ONLY AVAILABLE WITH -02 & -B4 WIRE OPTION NOT AVAILABLE WITH -EC OPTION ASSEMBLY LENGTH (cm) 1% C HDRL-11 (SEE NOTE 5) J1 J2 A19 A1 A1 A19 7.98 .314 REF PCB-108173-ECUE-02 (2 PLCS) 11.50 .453 REF 20.10 .791 REF 01 10 B19 B1 B19 B1 10 01 FIG 1 WIRING OPTION -01 ECUE-12-XXX-C1-FF-01-1 SHOWN ECUE-XX-XXX-XX-XX-XX-1-XX FIREFLY CABLE ASSEMBLY SHEET OF BY: ECUE-XX-XXX-XX-XX-XX-1-XX DWG. NO. DESCRIPTION: DO NOT SCALE DRAWING RMSANTOS 10/9/2014 6 1 TOLERANCES DO NOT APPLY TO REFERENCE DIMENSIONS. .X: .3[.01] 2 .XX: .13[.005] .XXX: .051[.0020] DECIMALS ANGLES TOLERANCES ARE: UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE IN MILLIMETERS. DECIMALS ANGLES F:\DWG\MISC\MKTG\ECUE-XX-XXX-XX-XX-XX-1-XX-MKT.SLDDRW 520 PARK EAST BLVD, NEW ALBANY, IN 47150 PHONE: 812-944-6733 FAX: 812-948-5047 e-Mail [email protected] code 55322 NOTES: 1. C REPRESENTS A CRITICAL DIMENSION 2. PARTS TO BE PROCESSED PER SAMTEC WORKMANSHIP GUIDELINES 3. ALL ASSEMBLIES TO BE 100% ELECTRICALLY TESTED 4. ALL ASSEMBLIES TO BE 100% HI-POT TESTED AT 300V 5. LABEL TO BE CENTERED ON CABLE AS SHOWN. LABEL TO CONTAIN: LINE 1 - PART NUMBER “ECUE-XX-XXX-XX-XX-XX-1-XX” LINE 2 - SHOP ORDER NUMBER “XXXXXX” LINE 3 - DATE CODE “XXXXX” LINE 4 - PATENT PENDING 6. FOR SUB-ASSEMBLY AND FINISHED GOOD PACKAGING REQUIREMENTS, REFERENCE SAMTEC PACKAGING STANDARD 7. -D1 OPTION USES 0.1µF DECOUPLING CAPACITORS 8. CABLE LENGTHS LONGER THAN 150 cm NOT SUPPORTED BY SI TEST DATA 9. PIN 3 ON UCC8 CONNECTION TIED TO GROUND, REMAINDER ARE NO CONNECT HOUSING: LCP LATCH: STAINLESS STEEL WELD TAB: BRASS CABLE: JACKET: PVC DIELECTRIC: FEP CONDUCTORS: SILVER PLATED COPPER SHIELD: SERVED SILVER PLATED COPPER PCB: FR4, COPPER MATERIAL: REVISION J

Transcript of ECUE-XX-XXX-XX-XX-XX-1-XX-MKT - Samtec...

Page 1: ECUE-XX-XXX-XX-XX-XX-1-XX-MKT - Samtec …suddendocs.samtec.com/prints/ecue-xx-xxx-xx-xx-xx-1-xx...THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN, MANUFACTURING,

THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN, MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC, INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS WRITTEN CONSENT OF SAMTEC, INC.

PROPRIETARY NOTE* *

THIS PRODUCT MANUFACTUREDWITH LEAD-FREE PROCESSINGPb

CC

NOT TOOLED*

NOT TOOLED*

DO NOTSCALE FROM

THIS PRINT

*

DESIGNED & DIMENSIONEDIN MILLIMETERS[INCHES]

No OF PAIRS

END 2 OPTION

ASSEMBLY LENGTH

SHIELDED CABLE TYPE

OPTION

WIRING OPTION (SEE TABLE 1)

-1

-12 (T1 & C1 CABLE ONLY)-08 (T2 CABLE ONLY)

007 - 999 cm (SEE NOTE 8)

-C1: TCF-3850 (38AWG COAX,12 PAIRS ONLY)-T1: TTF-36100 (36AWG TWINAX,12 PAIRS ONLY)-T2: TTF-34100 (34AWG TWINAX, 8 PAIRS ONLY)

-FF: ECUE-EC: ECDP

-01 "A1 TO A19" -02 "A1 TO B1"-B4 (8 PAIR ONLY) "A1 TO B19"

(LOW PROFILE)

BLANK: STANDARD FIREFLY-D1: DECOUPLING CAPACITORS (SEE NOTE 7) ONLY AVAILABLE WITH -02 & -B4 WIRE OPTION NOT AVAILABLE WITH -EC OPTION

ASSEMBLY LENGTH (cm) 1% C

HDRL-11(SEE NOTE 5)

J1 J2

A19

A1

A1

A19

7.98 .314REF

PCB-108173-ECUE-02 (2 PLCS)

11.50 .453REF

20.10 .791 REF01

10B19

B1 B19

B1

10

01FIG 1WIRING OPTION -01

ECUE-12-XXX-C1-FF-01-1 SHOWN

ECUE-XX-XXX-XX-XX-XX-1-XX

FIREFLY CABLE ASSEMBLY

SHEET OFBY:ECUE-XX-XXX-XX-XX-XX-1-XXDWG. NO.

DESCRIPTION:DO NOT SCALE DRAWING

RMSANTOS 10/9/2014 61

TOLERANCES DO NOT APPLYTO REFERENCE DIMENSIONS.

.X: .3[.01] 2

.XX: .13[.005]

.XXX: .051[.0020]

DECIMALS ANGLESTOLERANCES ARE:

UNLESS OTHERWISE SPECIFIED,DIMENSIONS ARE IN MILLIMETERS.

DECIMALS ANGLES

F:\DWG\MISC\MKTG\ECUE-XX-XXX-XX-XX-XX-1-XX-MKT.SLDDRW

520 PARK EAST BLVD, NEW ALBANY, IN 47150PHONE: 812-944-6733 FAX: 812-948-5047e-Mail [email protected] code 55322

NOTES: 1. C REPRESENTS A CRITICAL DIMENSION 2. PARTS TO BE PROCESSED PER SAMTEC WORKMANSHIP GUIDELINES 3. ALL ASSEMBLIES TO BE 100% ELECTRICALLY TESTED 4. ALL ASSEMBLIES TO BE 100% HI-POT TESTED AT 300V 5. LABEL TO BE CENTERED ON CABLE AS SHOWN. LABEL TO CONTAIN:

LINE 1 - PART NUMBER “ECUE-XX-XXX-XX-XX-XX-1-XX”LINE 2 - SHOP ORDER NUMBER “XXXXXX”LINE 3 - DATE CODE “XXXXX” LINE 4 - PATENT PENDING

6. FOR SUB-ASSEMBLY AND FINISHED GOOD PACKAGING REQUIREMENTS, REFERENCE SAMTEC PACKAGING STANDARD 7. -D1 OPTION USES 0.1µF DECOUPLING CAPACITORS 8. CABLE LENGTHS LONGER THAN 150 cm NOT SUPPORTED BY SI TEST DATA 9. PIN 3 ON UCC8 CONNECTION TIED TO GROUND, REMAINDER ARE NO CONNECT

HOUSING: LCPLATCH: STAINLESS STEELWELD TAB: BRASSCABLE: JACKET: PVC DIELECTRIC: FEP CONDUCTORS: SILVER PLATED COPPER SHIELD: SERVED SILVER PLATED COPPERPCB: FR4, COPPER

MATERIAL:

REVISION J

Page 2: ECUE-XX-XXX-XX-XX-XX-1-XX-MKT - Samtec …suddendocs.samtec.com/prints/ecue-xx-xxx-xx-xx-xx-1-xx...THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN, MANUFACTURING,

THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN, MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC, INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS WRITTEN CONSENT OF SAMTEC, INC.

PROPRIETARY NOTE* *

3.81 .150

1.78 .070

0.76 .030

C

C

C

SOLDER DIPPED

STRIP DIMENSIONS

PRESS FIT HOLES

WT-101-01-T

ECUE-12-2

6.08 .239APPLY TO BOTH ENDS

OF THE HOUSING

C

IN PROCESS 3INSERT WELD TABS & ATTACH TO BOARD

LTC-43-01

IN PROCESS 4ATTACH LATCH AND

ROTATE INTO DOWN POSITION

IN PROCESS 5SOLDER WELD TABS

FIRST CABLE CUT LENGTH = ASSEMBLY LENGTH (cm) - "A" (mm) ± 1%

(SEE TABLE 3)

IN PROCESS 1SOLDER FIRST CABLE TO PCB

IN PROCESS 2SOLDER SECOND CABLE TO PCB

SECOND CABLE CUT LENGTH = ASSEMBLY LENGTH (cm) - "B" (mm) ± 1%

(SEE TABLE 3)

FIREFLY CABLE ASSEMBLY

SHEET OFBY:ECUE-XX-XXX-XX-XX-XX-1-XXDWG. NO.

DESCRIPTION:DO NOT SCALE DRAWING

RMSANTOS 10/9/2014 62F:\DWG\MISC\MKTG\ECUE-XX-XXX-XX-XX-XX-1-XX-MKT.SLDDRW

REVISION J

520 PARK EAST BLVD, NEW ALBANY, IN 47150PHONE: 812-944-6733 FAX: 812-948-5047e-Mail [email protected] code 55322

Page 3: ECUE-XX-XXX-XX-XX-XX-1-XX-MKT - Samtec …suddendocs.samtec.com/prints/ecue-xx-xxx-xx-xx-xx-1-xx...THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN, MANUFACTURING,

THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN, MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC, INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS WRITTEN CONSENT OF SAMTEC, INC.

PROPRIETARY NOTE* *

A19

A1 B1

B19

J2J1

SUB-TTF-36100-12-01-XX.XX

B19

B1

A19

A1

FIG 2WIRING OPTION -02

ECUE-12-XXX-T1-FF-02-1-D1 SHOWN(SAME AS FIG 1 EXCEPT AS NOTED)

SHEET OF

FIREFLY CABLE ASSEMBLY

BY:ECUE-XX-XXX-XX-XX-XX-1-XXDWG. NO.

DESCRIPTION:

RMSANTOS 10/9/2014 63F:\DWG\MISC\MKTG\ECUE-XX-XXX-XX-XX-XX-1-XX-MKT.SLDDRW

REVISION J

520 PARK EAST BLVD, NEW ALBANY, IN 47150PHONE: 812-944-6733 FAX: 812-948-5047e-Mail [email protected] code 55322

Page 4: ECUE-XX-XXX-XX-XX-XX-1-XX-MKT - Samtec …suddendocs.samtec.com/prints/ecue-xx-xxx-xx-xx-xx-1-xx...THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN, MANUFACTURING,

THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN, MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC, INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS WRITTEN CONSENT OF SAMTEC, INC.

PROPRIETARY NOTE* *

THIS PRODUCT MANUFACTUREDWITH LEAD-FREE PROCESSINGPb

A19

A1

B19

B1

SUB-ECUE-12-C1-1-D1(2PLCS)

10.43 .411 REF

BLACK SOLDER MASK

1

2

19.80 .779 REFA1

A19B19

B1

FIG 3ECUE-12-XXX-C1-FF-02-1-D1 SHOWN(SAME AS FIG 1 EXCEPT AS NOTED)

J2J1

J1 & J2SUB-ECUE-12-C1-1-D1

SHEET OF

FIREFLY CABLE ASSEMBLY

BY:ECUE-XX-XXX-XX-XX-XX-1-XXDWG. NO.

DESCRIPTION:

RMSANTOS 10/9/2014 64F:\DWG\MISC\MKTG\ECUE-XX-XXX-XX-XX-XX-1-XX-MKT.SLDDRW

REVISION J

520 PARK EAST BLVD, NEW ALBANY, IN 47150PHONE: 812-944-6733 FAX: 812-948-5047e-Mail [email protected] code 55322

Page 5: ECUE-XX-XXX-XX-XX-XX-1-XX-MKT - Samtec …suddendocs.samtec.com/prints/ecue-xx-xxx-xx-xx-xx-1-xx...THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN, MANUFACTURING,

THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN, MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC, INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS WRITTEN CONSENT OF SAMTEC, INC.

PROPRIETARY NOTE* *

ORANGE CABLE COLOR SHOWNFOR ROUTING CLARITY ONLY

(CABLES CROSS)A19

A1

A1

A19

J2J1

B1

B19B1

B19

FIG 4WIRING OPTION -B4

ECUE-08-XXX-T2-FF-B4-1-D1 SHOWN(SAME AS FIG1 EXCEPT AS NOTED)

FIREFLY CABLE ASSEMBLY

SHEET OFBY:ECUE-XX-XXX-XX-XX-XX-1-XXDWG. NO.

DESCRIPTION:DO NOT SCALE DRAWING

RMSANTOS 10/9/2014 65SHEET SCALE: 1:1

F:\DWG\MISC\MKTG\ECUE-XX-XXX-XX-XX-XX-1-XX-MKT.SLDDRW

REVISION J

520 PARK EAST BLVD, NEW ALBANY, IN 47150PHONE: 812-944-6733 FAX: 812-948-5047e-Mail [email protected] code 55322

Page 6: ECUE-XX-XXX-XX-XX-XX-1-XX-MKT - Samtec …suddendocs.samtec.com/prints/ecue-xx-xxx-xx-xx-xx-1-xx...THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN, MANUFACTURING,

THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN, MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC, INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS WRITTEN CONSENT OF SAMTEC, INC.

PROPRIETARY NOTE* *

28.85 1.136REF

20.93 .824REF

A19

A1

LTC-32-XX(2PLCS)

STS-01(2 PLCS)

J2J1

37 38

21

A19

A1

J2J1

12

38 37

PCB-104465-HDR-01(2 PLCS) (*)

ECDP-12-01 (*)

ECDP-12-02 (*)

FIG 5ECUE-12-XXX-C1-EC-01-1 SHOWN(SAME AS FIG1 EXCEPT AS NOTED)

FIG 6ECUE-12-XXX-C1-EC-02-1 SHOWN(SAME AS FIG6 EXCEPT AS NOTED)

*NOT TOOLED

*NOT TOOLED

*NOT TOOLED

FIREFLY CABLE ASSEMBLY

SHEET OFBY:ECUE-XX-XXX-XX-XX-XX-1-XXDWG. NO.

DESCRIPTION:DO NOT SCALE DRAWING

RMSANTOS 10/9/2014 66SHEET SCALE: 1:1

F:\DWG\MISC\MKTG\ECUE-XX-XXX-XX-XX-XX-1-XX-MKT.SLDDRW

REVISION J

520 PARK EAST BLVD, NEW ALBANY, IN 47150PHONE: 812-944-6733 FAX: 812-948-5047e-Mail [email protected] code 55322