E024S
7326421 - Rev. A
E024S
ATTENZIONE
PRIMA DI EFFETTUARE IL SETUP SELEZIONARE CON I DIP SWITCH DS1(DS3-DS4) L’OPERATORE COLLEGATO ALL’APPARECCHIATURA E024S.PER TUTTI GLI ALTRI SETTAGGI FARE RIFERIMENTO AL MANUALE ISTRUZIONI E024S.
ATTENTION
BEFORE PERFORMING THE SETUP, SELECT THE OPERATOR CONNECTED TO THE E024S EQUIPMENT WITH THE DS1(DS3-DS4) DIP SWITCHES.FOR ALL OTHER SETTINGS, REFER TO THE E024S INSTRUCTION MANUAL.
ATTENTION
AVANT D'EFFECTUER LE SETUP, SÉLECTIONNER L'OPÉRATEUR CONNECTÉ À L'ÉQUIPEMENT E024S À L'AIDE DES DIP SWITCH DS1(DS3-DS4).POUR TOUTES LES AUTRES OPÉRATIONS DE SETUP, REPORTEZ-VOUS AU MANUEL D'INSTRUCTIONS E024S.
ACHTUNG
VOR DER DURCHFÜHRUNG EINES SETUPS MUSS MIT DEN DIP-SWITCHES DS1(DS3-DS4) DER AN DIE ANLAGE E024S ANGESCHLOSSENE ANTRIEB ANGEWÄHLT WERDEN.ANLEITUNGEN ÜBER ALLE ANDEREN EINSTELLUNGEN SIND DER BETRIEBSANLEITUNG E024S ZU ENTNEHMEN.
ATENCIÓN
ANTES DE EFECTUAR EL SETUP SELECCIONAR CON LOS DIP SWITCHES DS1 (DS3-DS4) EL OPERADOR CONECTADO AL EQUIPO E024S.PARA TODAS LAS OTRAS CONFIGURACIONES TOMAR COMO REFERENCIA EL MANUAL DE INSTRUCCIONES E024S.
LET OP
ALVORENS DE SETUP UIT TE VOEREN, MOET MET DE DIPSCHAKELAARS (DS3-DS4) DE AANDRIJVING WORDEN GESELECTEERD DIE OP HET APPARAAT E024S IS AANGESLOTEN.RAADPLEEG VOOR ALLE ANDERE INSTELLINGEN DE INSTRUCTIEHANDLEIDING E024S.
DS4 DS3 DS2 DS1 Description
OFF OFF 391
ON OFF S418
OFF ON 412-413-415-390-770
ON ON HYDRAULIC MOTORS450H/S700H/S800H/S800H ENC
OFF OFF LOW FORCE
ON OFF MEDIUM - LOW FORCE
OFF ON MEDIUM - HIGH FORCE
ON ON HIGH FORCE
E024S 3 732642 - Rev. F
WARNINGS• Important!Forthesafetyofpeople,itisimportantthatalltheinstructionsbecarefullyobserved.• Incorrectinstallationorincorrectuseoftheproductcouldcauseseriousharmtopeople.• Carefullyreadtheinstructionsbeforebeginningtoinstalltheproductandkeepthemforfuturereference.• Thesymbol indicatesnotesthatareimportantforthesafetyofpersonsandforthegoodconditionoftheautomatedsystem.
• Thesymbol drawsyourattentiontothenotesonthecharacteristicsandoperationoftheproduct.
CE DECLARATION OF CONFORMITY Manufacturer: FAACS.p.A.Address: ViaCalari,10-40069ZolaPredosaBOLOGNA-ITALYDeclares that: Controlboardmod.E024S,
•conformstotheessentialsafetyrequirementsofthefollowingEECdirectives: 2006/95/ECLowVoltageDirective
2004/108/EC ElectromagneticCompatibilityDirective Additionalinformation: Thisproductunderwentatestinatypical,uniformconfiguration. (allproductsmadebyFAACS.p.A)Bologna10-11-2014 CEO A.Marcellan
INDEX BOX LAYOUT ............................................................................................................................................4
1 WARNINGS E024S ............................................................................................................................5
2 LAYOUT AND CONNECTIONS E024S .................................................................................................5
1 WARNINGS E024S FITTED ON 391 .....................................................................................................6
2 LAYOUT AND CONNECTIONS E024S FITTED ON 391 .........................................................................6
3 TECHNICAL SPECIFICATIONS ...........................................................................................................73.1 DESCRIPTION OF COMPONENTS ........................................................................................................ 7
3.2 DESCRIPTION OF TERMINAL-BOARDS ................................................................................................. 7
3.3 ANTI-CRUSHING FUNCTION ................................................................................................................ 7
4 PROGRAMMING THE LOGIC ............................................................................................................7
5 PROGRAMMING THE SPEED ..............................................................................................................7
6 START-UP ...........................................................................................................................................86.1 LEDS CHECK...................................................................................................................................... 8
6.2 PROGRAMMING THE DIP-SWITCHES ................................................................................................... 8
6.3 TIME LEARNING – SETUP ..................................................................................................................... 8
6.3.1 AUTOMATIC SETUP .................................................................................................................................................8 6.3.2 MANUAL SETUP ......................................................................................................................................................86.3.3 PROGRAMMING THE LOGIC .....................................................................................................................................96.3.4 SECOND LEVEL PROGRAMMING ............................................................................................................................96.3.5 RETURN TO DEFAULT SETTINGS..............................................................................................................................106.3.6 PARAMETER DEFINITION .......................................................................................................................................10
7 INSTALLATION OF BUS ACCESSORIES ..............................................................................................107.1 SETTING THE BUS PHOTOCELLS ......................................................................................................... 10
7.2 MEMORY STORAGE OF BUS ACCESSORIES ...................................................................................... 11
8 MEMORY STORING THE RADIO CODE .............................................................................................118.1 MEMORY STORAGE OF DS RADIO CONTROLS ........................................................................................................................... 11
8.2 MEMORY STORAGE OF SLH-SLH LR RADIO CONTROLS .................................................................................................................. 11
8.3 MEMORY STORAGE OF RC/LC RADIO CONTROLS .............................................................................................. 12
8.3.1 REMOTE MEMORY STORAGE OF RC/LC RADIO CONTROLS ..................................................................................128.4 RADIO CONTROLS DELETION PROCEDURE ....................................................................................... 12
9 BATTERY KIT OF E024S (OPTIONAL)..................................................................................................12 9.1 BATTERY KIT OF E024S ON 391 (OPTIONAL) ........................................................................................ 13
10 AUTOMATED SYSTEM TEST ...............................................................................................................13
11 BUS ENCODER WIRING ..................................................................................................................13
12 FUNCTION LOGICS .........................................................................................................................15
EN
GLIS
H
E024S 4 732642 - Rev. F
A
A CB
C
225
Fig.B Fig.F
Fig.C
Fig.D
Fig.E
230V -> 2,5A - 250V 115V -> 4A - 120V
Fig.A130
64
306
BOX LAYOUT
Fig.Bshowsthefour5mmdiam.holesforsecuringthebox(ref.a)tothewall,thethreefacilitiesforistallingthecablegrip-persM16/M20/M25(ref.b)andthetwocoverhinges(ref.c).
THE BOX CONTAINS THE E024S CONTROL UNIT AND THE DEVICES TO POWER IT. IT MUST THEREFORE BE HANDLED WITH CARE DURING ALL INSTALLATION STAGES, TO AVOID DAMAGING ITS COMPONENTS.
ThedimensionsoftheboxareshowninFig.A:
Thecoverhingescanbemovedupwardtoallowopeningtheboxhousing(Fig.C);theycanalsoberemovedandre-posi-tionedinordertoenablethecovertoopentotherightorleft.
Whenyouhavesecuredtheboxintheselectedposition,coverthesecuringholes(ref.a Fig.B)andthescrewswiththesuppliedplugsasshowninFig.D.
ConnectthepowercableasshowninFig.E.Afterhavingconnectedthecontrolboardtothedifferentpartsoftheautomatedsystem,closetheboxbyplacingthecoveronitsseatwithgasket.
Dimensions in mm
ELECTRICAL BOX E024S
Next,tightenthefoursuppliedscrewstoguaranteethedegreeofprotectionagainstexternalagents(Fig.F).
EN
GLIS
H
E024S 5 732642 - Rev. F
~
=
=
=
=
1 WARNINGS E024S
Before attempting any work on the control unit (connections, maintenance), always turn off power.- Install, upstream of the system, a differential thermal breaker with adequate tripping threshold,- Always separate power cables from control and safety cables (push-button, receiver, photocells, etc.).- To avoid any electrical disturbance, use separate sheaths or a shielded cable (with the shield earthed).
CONTROL UNIT E024S
2 LAYOUT AND CONNECTIONS E024S
(PARTIALOPENING)
(TOTALOPENING)
230 V~ 50HZor
115 V~ 60Hz *1
*1 THE POWER SUPPLY IS RELATED TO THE E024S PURCHASED VERSION.
Fig.1A
Motorsconnection2x2.5 mm ² / AVG 12for motor (minimum) (Max. length 20 m)
EN
GLIS
H
E024S 6 732642 - Rev. F
~ =
=
= =
1 WARNINGS E024S FITTED ON 391
Before attempting any work on the control unit (connections, maintenance), always turn off power.- Install, upstream of the system, a differential thermal breaker with adequate tripping threshold,- Always separate power cables from control and safety cables (push-button, receiver, photocells, etc.).- To avoid any electrical disturbance, use separate sheaths or a shielded cable (with the shield earthed).
CONTROL UNIT E024S fitted on 391
2 LAYOUT AND CONNECTIONS E024S FITTED ON 391
(PARTIALOPENING)
(TOTALOPENING)
230 V~ 50HZor
115 V~ 60Hz *1
*1 THE POWER SUPPLY IS RELATED TO THE E024S PURCHASED VERSION.
Fig.1B
Motorsconnection2x2.5 mm ² / AVG 12for motor (minimum) (Max. length 20 m)
EN
GLIS
H
E024S 7 732642 - Rev. F
3 TECHNICAL SPECIFICATIONS
Power supply voltage *230V~(+6%-10%)-50Hz
or115V~(+6%-10%)-60Hz
Absorbed power 4W
Motor max. load 150Wx2
Accessories max. current (+24V=)
250mA
BUS Accessories max.current 400mA
Operating ambient tempera-ture
-20°C...+55°C
Fuses *F1=self-resetting;
F2 = T2A-250V~ or T4A-120V~
Function logics A,E,AP,EP,A1,B,C
Work time (time-out) 5minutes(fixed)
Pause timeVariesaccordingtolearning
(max.10min.)
Terminal board inputsOpenA,OpenB,Stop,BUS
(I/O)
Connector inputsPowersupply,battery
moduleXF433orXF868
Terminal board outputs
Motors,flashinglamp,powersupplytoaccessories,elec-triclock,servicelightcontact
(90secfixed)
Programmable functions Speed(High-Low)
Learning functions Pausetime,leafclosingdelay
Integrated radio channels type
DS,SLH(max250channels)LC-RC(max250channels)
J1 POWERSUPPLYconnector
J2 SERVICELIGHTcommandterminal-board
J3 FLASHINGLAMPterminal-board
J4 ELECTRICLOCKterminal-board
J5 COMMANDSterminal-board
J7 MOTOR1terminal-board
J8 MOTOR2terminal-board
J9 RapidconnectionforXFMODULE
J10 BUSterminal-board
J11 BATTERYconnector
SW1 SETUPpush-button
SW2 SPEEDpush-button
SW3 LOGICpush-button
DS1 ProgrammingDip-switch
F1 Accessoriesprotectivefuse
F2 Fusesprotectingtransformersandmotors
LED SignallingLEDs
3.1 DESCRIPTION OF COMPONENTS
Terminal and/or terminal-board Description Device connected
1
J5
+24V= Powersupplyforaccessories
2 GND Negative
3 STOP
DevicewithNCcontactwhichcausestheautomatedsystemtoshutdown
4 OPENB DevicewithN.Ocontact5 OPENA
J10REDterminal
BUS SafetydeviceswithBUStechnology
J2GREYterminal
SERVICE LIGHT(onfor90sec.followingmovement)
ServiceLightcontroloutput(connectarelaycoilat24V=/100mAmax)
J3ORANGEterminal LAMP Flashinglamp
24V= / 15W
J4BLUEterminal LOCK
Electriclock12V~or24V=(tobeinstalledonleaf1)
J7 MOT1 Motor1(leaf1)
J8 MOT2 Motor2(leaf2)
3.2 DESCRIPTION OF TERMINAL-BOARDS
5 PROGRAMMING THE SPEEDThefunctionSPEEDcanbeadjustedatanytimebypressingpush-buttonSW2.TheselectedspeedisthendisplayedonLEDLD8:
LEDon =HIGHspeed LEDoff =LOWspeed
Leaf 1 means the leaf which opens first during the opening operation.
The service light control is active during the entire gate opening or closing movement and for the successive 90 seconds.
*Thepowersupplyandthefusearerelatedtothepurchasedversion. Theself-resettingfuseF1stopsthepowersupplytotheaccessoriesbyopeningacircuit ifacurrentover500mAisdetected.Itautomaticallyresetsafter5seconds.
3.3 ANTI-CRUSHING FUNCTIONTheelectronicanti-crushingfunctionisobtainedbycontrollingthe current consumption or the encoder of themotorsconnectedtotheE024Sunit.Ifthegatedetectsanobstacleduringtheopeningorclosingmovement,theanti-crushingfunctionactivatesandreversesthesenseofdirectionoftheoperator,thusincreasingthesafetydegreeoftheautomatedsystem.
4 PROGRAMMING THE LOGIC RepeatedlypresstheSW3LOGICpush-buttontoselectoneofthe7programminglogicsavailable.TheselectedlogicissignaledbytheLD7LED:thenumberofflashingscorrespondstothenumberoftheselectedlogic.See paragraph 6.3.3.
EN
GLIS
H
E024S 8 732642 - Rev. F
6 START-UP6.1 LEDS CHECK
Checkthestatusoftheinputs,fromtheLEDsontheboard(Tab.1).Tab.1:inputLEDstatus(theconditionofclosedautomation instandby isprovided inbold)
LED STATUSES
LED ACTIVE CONTROL NOT ACTIVE CONTROL
STOP Off On
OPENA On Off
OPENB On Off
BUS Seeparagraph7.2
6.2 PROGRAMMING THE DIP-SWITCHESThesettingsoftheDS1dip-switchforprogrammingtheforceandthetypeofmotorareshowninthefollowingtable.
Tab. 2 - DS programming
(default settings in bold)
Before performing the Setup, select the op-erator connected to the E024S unit with the DS1(DS3-DS4) DIP switches.
6.3.1 AUTOMATIC SETUP
ToentertheAutomaticsetup,presstheSETUPpush-buttonuntilthetwoLD4andLD5LEDsarepermanentlylit.ThenreleasetheSETUPpush-button.
DuringtheSetupphasebothLEDsflash.
Theleavesstarttoopenoneatatime,fromanyposition,tilltheydetecttheopeninglimitstop.Next,theleavesstarttoclose,oneatatime,tilltheydetecttheclosinglimitstop.
Then,theleavesstartagaintomoveautomaticallyoneatatimefromtheclosedposition.
1. Whentheleavesdetecttheopeninglimitstop,theystopin
theopenpositionandtheset-upiscompleted.
IftheSETUPprocedureisperformedcorrectly,theLD4andLD5LEDsturnoffattheend.OtherwisetheprocedureendsbyaskinganewSETUPwithflashingLEDs.
With the AUTOMATIC SETUP, the deceleration spaces, the leaf closing delays and the pause time (30 s, with logic A) are automatically preset during setup.
6.3.2 MANUAL SETUP
Toenter theManualsetup,press theSETUPpush-buttonuntilbothLD4,presstheSETUPpush-buttonuntilthetwoLD4andLD5LEDsarepermanentlylit.Keepitpresseduntiltheautomatedsystemstartsmovingautomatically.
DuringtheSetupphasebothLEDsflash.
Theleavesstarttoopenoneatatime,fromanypositiontilltheydetecttheopeninglimitstop.Nexttheleavesstarttocloseoneatatimetilltheydetecttheclosinglimitstop.
Thentheleavesstartagaintomoveautomaticallyoneatatimefromtheclosedposition.
1.Openimpulse--->leaf1deceleratedopeningandstartof thesearchforleaf1openinglimitstop -ifthelimitstopisdetected,itissetasstoppointforleaf1 andleaf2startstoopen.(*)ifanopencommandisdetected,itissetasopeningstoppointforleaf1andleaf2startstoopen.2.Openimpulse--->leaf2deceleratedopeningandstartofthesearchforleaf2openinglimitstop. -ifthelimitstopisdetected,itissetasopeningstoppointforleaf2. (*)ifanopencommandisdetected,itissetasopeningstop pointforleaf2.
DS4 DS3 DS2 DS1 Description
OFF OFF MOTOR 391
ON OFF MOTOR 418
OFF ON MOTOR 412-413-415-390-770
ON ON HYDRAULICMOTOR(*)S450H/S700H/S800H/S800H ENC
OFF OFF LOW FORCE
ON OFF MEDIUM - LOW FORCE
OFF ON MEDIUM - HIGH FORCE
ON ON HIGH FORCE
6.3 TIME LEARNING – SETUP
Before any manoeuvre is executed, a SETUP cycle must first be run.
If the motor type is changed with the DS3 and DS4 dip-switches after the SETUP, a new SETUP is requested with flashing LD4 and LD5 LEDs.
If, after the start of the SETUP procedure, the leaves close instead of open, reverse the motor power cables
(*) with the DS3-DS4 selection on ON the opera-tor connected to the encoder is automatically recognized during the set-up phase
Important:
The dip-switch arrangement on the E024S board for 391 is overturned.
WhentheboardispoweredupandaSETUPcyclehasneverbeenexecuted,LEDsLD4andLD5begintoflashslowlytosignalthataSETUPcyclemustbeexecuted.TherearetwopossibletypesofSETUP:-AUTOMATICSETUP-MANUALSETUP
(*) During SETUP, to set the stop point, the OPEN command must ONLY be used with SAFECODER
EN
GLIS
H
E024S 9 732642 - Rev. F
DescriptionPressing
SW2 (Speed)
LD7 LED status
(Logic)
LD8 LED flashing (Speed)
1
Windproof function
(anti-crushing sensitivity)
Once
Enabled ON (low obstacle sensitivity)
Disabled OFF (high obstacle sensitivity)
1 flash
2 Reversing stroke twice Enabled ON Disabled OFF
Flashing twice
3 Soft-Touch 3 times Enabled ON Disabled OFF
Flashing 3 times
4 Pre-flashing 4 times Enabled ON Disabled OFF
Flashing 4 times
5 Leaf opening delay 5 times Enabled ON ( 2 sec.)
Disabled OFF Flashing 5 times
6Leaf closing delay*( Default 5 s)
6 times
ON (SW3 pressing)OFF (no pressure)
Flashing 6 times
7 Pause time*(Default 30 s) 7 times ON (SW3 pressing)
OFF (no pressure) Flashing 7 times
8
Stop point search space
(function only active if SAFECODER available)
8 times HIGH (Short leaf) OFF LOW (Long leaf) ON
Flashing 8 times
6.3.3 PROGRAMMING THE LOGIC
RepeatedlypresstheSW3push-buttontoselectoneofthe7programminglogicsavailable.TheselectedlogicissignaledbytheLD7LED.Thenumberofflashingscorrespondstothenumberoftheselectedlogic: (default settings in bold)
3.Fromnowon,untilnextopenimpulse,thepausetimeis counted.
4.Openimpulse--->Pausetimeacquisitionandstartofleaf 2closingmovement.
5.Openimpulse--->leaf2deceleratedclosureandstartof thesearchforleaf2closinglimitstop. -ifthelimitstopisdetected,itissetasleaf2stoppointand leaf1startstoclose.(*) ifanopencommandisdetected,itissetasleaf2stop pointandleaf1startstoclose.
6.Openimpulse--->leaf1deceleratedclosureandstartof thesearchforleaf1closinglimitstop.
- ifthelimitstopisdetected,itissetasleaf1closingstop point.
(*)ifanopencommandisdetected,itissetasleaf1closing stoppoint.
If the SETUPprocedure is performedcorrectly, the LD4andLD5LEDsturnoffattheend.OtherwisetheprocedureendsbyaskinganewSETUPwithflashingLEDs.
To eliminate decelerated opening and closing, send 2 consecutive open impulses to determine the opening and closing stop point, otherwise have the leaf find the opening and closing limit stop if you want to use the limit stop facility.
With the MANUAL SETUP the decelerated spaces, the leaf closing delay and the pause time are manually set on the board during setup. You can modify them without repeating the setup procedure by using the 2nd level programming.
Logic Description SW3 pressing(LOGIC) LD7 flashing
A Logic A (Automatic) once Flashing onceE Semi-automatic twice Flashing twice
AP Step-by-step automatic 3 times Flashing 3 times
EP Step-by-step semi-automatic 4 times Flashing 4 times
A1 Automatic 1 5 times Flashing 5 timesb Semi-automatic “b” 6 times Flashing 6 timesc Dead man 7 times Flashing 7 times
6.3.4 SECOND LEVEL PROGRAMMING
Toenterthe2ndlevelmenu,presstheSW2SPEEDpush-buttonformorethan2.5seconds.BothSETUPLEDslightonwithsteadybeam.Inthismode,theSPEEDkeyhasthemenuscrollingfunction.Youcanscrollthemenubypressingitthesamenumberoftimesshownfortheparameter.ThedifferentmenusareidentifiedbythenumberofflashingofLD8.TheLOGICkeyisusedtosettheparametervalue.Youcanexitthe2ndlevelmenubypressingtheSPEEDkeyfor2.5seconds. (default settings in bold)
* With menus 6 and 7, keep the LOGIC push-button pressed until reaching the time to be set. The time can be set between 0 and 4.25 minutes.
EN
GLIS
H
E024S 10 732642 - Rev. F
7.1 SETTING THE BUS PHOTOCELLS
Important to give both the transmitter and the receiver the same address.
Make sure that there are not two or more pairs of photocells with the same address.
If no BUS accessory is used, leave the BUS con-nector free (J10 - fig. 1).
PAIR Dip1 Dip2 Dip3 Dip4 Ref. Type
1 OFF OFF OFF OFF
B-C OPENING
2 OFF OFF OFF ON
3 OFF OFF ON OFF
4 OFF OFF ON ON
5 OFF ON ON OFF
6 OFF ON ON ON
7 ON OFF OFF OFF
D CLOSING
8 ON OFF OFF ON
9 ON OFF ON OFF
10 ON OFF ON ON
11 ON ON OFF OFF
12 ON ON OFF ON
13 ON ON ON OFF
14 OFF ON OFF OFFA OPENING
andCLOSING15 OFF ON OFF ON
16 ON ON ON ON / OPENPULSE
Tab. 3 - Setting of bus photocells
Table3showstheprogrammingoperationsofthedip-switchinsidethetransmitterandoftheBUSPhotocellsreceiver.
Amaximumof16BUSphotocellpairscanbeconnectedtotheboard.Thephotocellsaresplitintogroups:
Openingphotocells: max6Closingphotocells: max7Opening/Closingphotocells: max2PhotocellusedasanOPENpulse: max1
Fig.2showsa2-swingleafautomatedsystemindicatingthecoveragebeamsofthephotocells:
A: PhotocellswithOPENINGandCLOSINGaction.
B: PhotocellswithOPENINGaction
C: PhotocellswithOPENINGaction
D: PhotocellswithCLOSINGaction
6.3.5 RETURN TO DEFAULT SETTINGS
Restorethedefaultsettingsasfollows:1. KeeptheSETUPpush-buttonpressedtoswitchtheboardON.2. BothSETUPLEDsarealternatelylit3. Theboardresetstheparameters.4. UntiltheSETUPpush-buttonispressed,movementsareinhibited.5. WhentheSETUPpush-buttonisreleased,bothLD4andLD5
LEDsflash.6. ThedefaultconfigurationisresetandthenewSetupcanbe
started.
Fig.26.3.6 PARAMETER DEFINITION
- Anti-wind:theantiwindfunctionenablesthegatetooperate eveniftherearegustsofwind.Theobstacledetectiontimeis setto5sandcommandsthereversalofmotion.
- Reversing stroke:whenthegateisclosed,thereversingstroke functionmakesitpossiblethatbeforetheopeningmovement, themotorspushtocloseforapprox.3stofacilitateuncoupling theelectriclock.
- Soft-touch:thesofttouchfunctionmakesitpossiblethat,after touchingtheclosinglimitstop,theleavesreverseandthen restgently.Thisfunctioncanbeusefultoobservetheimpact curveasrequestedbycurrentstandards.
- Pre-flashing:itactivatesapprox.3sbeforeeveryopening andclosingmovement
- Leaf delay at opening: itdelaystheleaf2startatopening withrespecttoleaf1,avoidingthusanyinterferencebetween theleaves.
- Leaf delay at closure: itdelaysleaf1atclosurewithrespect toleaf2.
- Pause time:InlogicAitisthetimesetfortheleafre-closure aftertheopening.
- Stop point search space: this parameter adjusts themechanicalstopsearchanglewithinwhichtheboardstopsthemovementwithoutreversingifanobstacleisencounteredorthemechanicalstopitselfcanbeadjusted.
7 INSTALLATION OF BUS ACCESSORIES
Thisboard is suppliedwithaBUScircuitenablingeasycon-nectionofahighnumberofBUSaccessories (e.g.upto16photocellspairs),appropriatelyprogrammed,usingonlytwocablewithoutpolarity.Belowwedescribe theaddressingandmemory storageoftheBUSphotocells.Forotherfutureaccessories,refertothespecificinstructions.
EN
GLIS
H
E024S 11 732642 - Rev. F
a
a
8 MEMORY STORING THE RADIO CODE
Thecontrolunithasanintegrated2-channeldecodingsystem(DS,SLH,LC)namedOMNIDEC.Thissystemmakesitpossibletomemory-storebothtotalopening(OPENA)andpartialopeningOPENB)oftheautomatedsystem-thisismadepossiblebyanadditionalreceivermodule(fig.3Aref.a)andFig.3Bref.1forE024Sfor391)andradiocontrolsonthesamefrequency.
The 3 types of radio codes (DS, LSH, RC) cannot coexist.
Only one radio code can be used at a time.
8.1 MEMORY STORAGE OF DS RADIO CONTROLS
A maximum of two codes can be stored. One on the OPEN A channel and one on the OPEN B channel.
1. On the DS radio control, select the requiredON-OFFcombinationforthe12dip-switches.
2. PresstheLOGIC(SW3)orSPEED(SW2)push-button,tomemorystorerespectivelytotalopening(OPENA)orpartialopening(OPENB),andasyouholditdown,alsopresstheSETUP(SW1)push-button.TherelevantLEDstartstoflashslowlyfor5sec.
3. Releasebothpush-buttons.4. Withinthese5sec.,presstheappropriatepush-buttononthe
radiocontrol.5. TherelevantLEDlightsuponsteadybeamfor1secondand
thengoesOFF,indicatingthatstoragewasexecuted.6. Toaddotherradiocontrols,setthesameON-OFFcombination
usedinpoint1.
8.2 MEMORY STORAGE OF SLH-SLH LR RADIO CONTROLS
A maximum of 250 codes can be memory stored, split between OPEN A and OPEN B.
1. OntheSLHradiocontrol,simultaneouslypressandholddownpush-buttonsP1andP2.
2. TheradiocontrolLEDbeginstoflash.3. Releasebothpush-buttons.4. Within5s,whiletheradiocontrolLEDisstillflashing,pressand
holddowntheselectedpush-buttonontheradiocontrol(theradiocontrolLEDlightsonwithsteadybeam).
5. Press the LOGIC (SW3) or SPEED (SW2) push-button torespectivelymemory store total opening (OPEN A) orpartialopening(OPENB)and,byholdingitdown,pressthe push-buttonSETUP(SW1
6. TheLEDontheboardlightsuponsteadybeamfor1secondandthengoesOFF,indicatingthatstoragewasexecuted.
7. Releasetheradiocontrolpush-button.8. Quicklypresstwicethememorystoredradiocontrolpush-
button.
The automated system performs one opening operation. Make sure that the automated
7.2 MEMORY STORAGE OF BUS ACCESSORIES
ItispossibletoaddBUSaccessoriestothesystematanytimebysimplysavingthemontheboard,inthefollowingmanner:1. Install andprogram theaccessories using the required
address(seeparagraph7.1)2. Cutpowertotheboard.3. Connectthetwoaccessoriescablestotheredterminal-board
J10(anypolaritywilldo).4. Poweruptheboard,takingcaretofirstconnectthemainpower
supply(transformeroutput)andthenanybatteriesandwaitfortheBUSLEDtolighton.
5. QuicklypressonceonlytheSW1(SETUP)push-button,toexecutelearning.TheBUSLEDflashes.
6. GiveanOPENimpulse,leaveswillmoveandtheBUSlearningprocedureisover.
TheboardhasmemorystoredtheBUSaccessories.FollowtheinstructionsinthetablebelowtocheckiftheBUSconnectioniscorrect.
Tab. 4 - Description of BUS LED
Steady lightNormal operation (LEDONeven in theabsenceofphotocells)
Slow flashing lamp (flashevery0.5sec)
At least one input engaged: photocellengagedornotaligned,OpenAorOpenBorStopinputengaged
Light OFF(flashevery2.5sec)
BUSlineshortcircuited
Fast flashing lamp (flashevery0.2sec)
If youhavedetecteda BUSconnectionerror,repeattheacquisitionprocedure.Iftheerrorisrepeated,makesurethatthereisnomore thanoneaccessorywith thesameaddressinthesystem(alsoseetheaccessoriesinstructions)
To change over from one code to another, you must delete the existing one (see paragraph on deletion), and repeat the memory-storage procedure.
Fig.3B
Fig.3A
E024S on 391
E024S in box
EN
GLIS
H
E024S 12 732642 - Rev. F
a
10 MM
16 MM16 MM
8.3.1 REMOTE MEMORY STORAGE OF RC/LC RADIO CONTROLS
OtherradiocontrolscanberemotelystoredonlywiththeRC/LCradiocontrols,i.e.withoutusingtheLOGIC-SPEED-SETUPpush-buttons,butusingapreviouslystoredradiocontrol.1. Getaradiocontrolalreadystoredononeofthe2channels
(OPENAorOPENB).2. Pressandholddownpush-buttonsP1andP2simultaneously
untilboththeLEDsflashslowlyfor5sec.3. Within5sec.pressthepush-buttonoftheradiocontrolthathad
beenmemorystoredtoenablelearningontheselectedchannel.
system is free of any obstacle created by persons or things.
To add other radio controls, transfer the code of the memory-storedpush-buttonoftheradiocontroltotherelevantpush-buttonoftheradiocontrolstobeadded,observingthefollowingprocedure.
• Onthememorystoredradiocontrol,simultaneouslypressandholddownpush-buttonsP1andP2.
• TheradiocontrolLEDbeginstoflash.• Releasebothpush-buttons.• Pressthememorystoredpush-buttonandholditdown(theradiocontrolLEDlightsuponsteadybeam).
• Bringtheradiocontrolsnear,pressandholddownthepush-buttonoftheradiocontroltobeadded,releasingitonlyafter thedouble flashof the radiocontrol LED,whichindicatesmemorystorageexecuted.
• Quicklypresstwicethepush-buttonofthememorystoredradiocontrol.
The automated system performs one opening operation. Make sure that the automated system is free of any obstacle created by persons or things.
8.3 MEMORY STORAGE OF RC/LC RADIO CONTROLS
A maximum of 250 codes can be memory stored, split between OPEN A and OPEN B.
1. UseRC/LCremotecontrolsonlywithreceivermoduleat433MHz.
2. PresstheLOGIC(SW3)orSPEED(SW2)push-button,tomemorystorerespectivelytotalopening(OPENA)orpartialopening(OPENB),andasyouholditdown,alsopresstheSETUP(SW1)push-button.TherelevantLEDstartstoflashslowlyfor5sec.
3. Releasebothpush-buttons.Withinthese5sec.,presstheappropriatepush-buttonontheRCorLCremotecontrol.
4. TheLEDlightsuponsteadybeamfor1second,indicatingmemorystorageexecuted,andthenresumesflashingforanother5sec.,duringwhichanotherradiocontrol(point4)canbememorystored.
5. Whenthe5sec.haveelapsed,theLEDgoesOFFindicatingtheendoftheprocedure.
6. Toaddotherradiocontrols,repeattheoperationatpoint1.
4. TheLEDontheboardrelatingtothechannelbeinglearnedflashesfor5sec.,withinwhichtimethecodeofanotherradiocontrolmustbetransmitted.
5. TheLEDlightsuponsteadybeamfor2seconds,indicatingmemorystorageexecuted,andthenresumesflashingfor5sec.,duringwhichotherradiocontrolscanbememorystored,andthengoesOFF.
8.4 RADIO CONTROLS DELETION PROCEDURE
1. TodeleteALLtheinputradiocontrolcodes,presspush-buttonLOGIC(SW3)orSPEED(SW2)and,whileholdingitdown,alsopresspush-buttonSETUP(SW1)for10sec.
2. TheLEDrelatingtothepressedpush-buttonflashesforthefirst5sec,andthenflashesmorequicklyforthenext5sec.
3. BothLEDslightuponsteadybeamfor2secandthengoOFF(deletion completed).
4. Releasebothpush-buttons.
This operation is NOT reversible. All codes of radio controls stored as OPEN A and OPEN B will be deleted.
9 BATTERY KIT OF E024S (OPTIONAL)Thebufferbatterykitwasbuilt for insertion inside thecontrolboardsupport.This support (Fig.4 ref.a) was pre-moulded to permit the batteryhousingtobeopened.1. Remove the board support material covering the
batteryhousing,cutting thematerialconnectionsalongtheperimeter.
2. Insertthebatteryinthehousingyouhavejustcreated,andsecureitontheanchoringsupports(Fig.5).
3. TocorrectlyfastenandconnectthecontrolunittotheJ11con-nector,refertotheinstructionsenclosedwiththebatterykit.
Fig.4
Fig.5
EN
GLIS
H
E024S 13 732642 - Rev. F
1
2 3.9x16
11 BUS ENCODER WIRING
10 AUTOMATED SYSTEM TESTWhenyouhavefinishedprogramming,checkifthesystemisoperatingcorrectly. Inparticular,checkifthesafetydevicesareoperatingcorrectly.
Fig.6
9.1 BATTERY KIT OF E024S ON 391 (OPTIONAL)
Thebatterykitenablesyoutoactivatetheautomatedsystemeven in theeventofamainspower fault.Thebatteriesarehousedinaspecificcompartment insidetheoperator(seesequenceinfig.6).Toinstall,refertothespecificinstructions.
The batteries start operating when mains voltage fails.
E024Sisusedtocontrolbusencoders.Anyencodersconnectedtotheredbusterminalarerecognisedduringbusdeviceacquisition(chapter7.2).Theuseofthistypeofencoderofferspreciseandconstantinformationonleafposition,guaranteeingreversemovementincaseofobstacles.Theencoder iscompulsoryonhydraulicoperators (S450H,S700H,S800H,S800HENC)andoptionalonelectromechanicaloperators.
Leaf1 Leaf2 Leaf1Leaf2
Leaf 1 opens as first and closes as second
Leaf 1 (DL1, DL2 on) Leaf 2 (DL1 on)
S450H, 412, 413, 415, 770 , 770NSAFECODER
Absolute encoder
DL1DL2DL3
DL1DL2DL3
S700H/S800HRelative encoder
DL1
DL2DL3
DL1
DL2DL3
S800H ENCRelative encoder
(It only works as a relative encoder on E024S)
DL1DL2DL3
DL1DL2DL3
1. Connectthe2encodercablestotheBUSinput(redterminal)ontheelectronicboard.2. EnsurethattheencoderLEDslightupasreportedinthetable.TheLEDsmustbecheckedwiththeleafstopped.
Fig.7
EN
GLIS
H
E024S 14 732642 - Rev. F
DL1DL2DL3
DL1DL2DL3
Fig.8
If necessary, swap the 2 connecting wires to obtain the correct coupling of the encoder with the leaf as indicated in the following figure.
LED ON FLASHING OFF
DL 1 PowersupplyonandBUSconnectedtoboard
PowersupplyonbutBUSnotconnected
NopowersupplyorBUScommunication
DL 2 Leaf1encoder -- Leaf2encoder
DL 3 -- Pulsereadingduringleafmovement --
EN
GLIS
H
E024S 15 732642 - Rev. F
LOGIC “A” PULSES
AUTOMATED SYSTEM STATUS OPEN A OPEN B STOP FSW OP FSW CL FSW CL/OP
CLOSED opensandclosesafterpausetime
opensreleasedleafandclosesafterpausetime
noeffect (OPENdisabled)
noeffect (OPENdisabled) noeffect noeffect
(OPENdisabled)
OPENING noeffect(1) noeffect stopsoperation reversesat closure noeffect stopsandopensat
release(savesCLOSE)
OPEN IN PAUSE recharges pausetime(1)
recharges pausetimeofreleasedleaf
stopsoperation noeffectrecharges pausetime
(CLOSEdisabled)
recharges pausetime
(CLOSEdisabled)
CLOSING reopensleavesimmediately
reopensleavesimmediately stopsoperation noeffect reversesatopening stopsandopensatrelease(savesCLOSE)
BLOCKED closesleaves closesleavesnoeffect (OPEN/CLOSEdisabled)
noeffect (OPENdisabled)
noeffect (CLOSEdisabled)
noeffect (OPEN/CLOSEdisa-
bled)
(1)ifthecyclebeganwithOPEN-B(releasedleaf),bothleavesareactivatedatopening
12 FUNCTION LOGICS
LOGIC Automation status:stopped
Automation status:moving
Status:triggered photocell
A Automatic anOPENpulseopensthegateandclosesautomaticallyafterthe
pausetime
AnOPENpulseisignoredwhenthegateopens,isreappliedduringthepauseandreopenswhenthe
gatecloses
Theclosingphotocellsreapplythepause
E Semiautomatic anOPENpulseopensthegateandthefollowingoneclosesit
AnOPENpulsestopsthegatewhenopeningandreopenswhen
thegateisclosingThephotocellsinvertduringmotion
EP Semi-automatic,Step-by-Step anOPENpulseopensthegate
andthefollowingoneclosesitAnOPENpulseblocksduring
motion Thephotocellsinvertduringmotion
A1 Automatic1anOPENpulseopensthegateandclosesautomaticallyafterthe
pausetime
AnOPENpulseisignoredwhenthegateopens,isreappliedduringthepauseandreopenswhenthe
gatecloses
Theclosingphotocellsclosethegateonceagainduringthepau-se;theymemoriseclosurewhenthegateopensandimmediately
invertwhenclosing
AP Automatic,Step-by-Step anOPENpulseopensthegateandclosesautomaticallyafterthe
pausetime
AnOPENpulseblockswhenthegateopensandduringthepause
andinvertswhenitcloses
Theclosingphotocellsreapplythepause
b Semi-automatic“b”(OPEN-BinputsbecomeCLOSE)
logicwithtwoseparatecom-mands:OPEN-Apulseopens;
CLOSEpulsecloses
AnOPEN-Apulseopenswhenthegatecloses,aCLOSEpulse
closeswhenitopens
Thephotocellsinvertduringmotion
C Dead-man(OPEN-BinputsbecomeCLOSE)
logicwithtwoseparatecom-mands:pressedOPEN-Aopens;
pressedCLOSEcloses
AnOPEN-Apulseopenswhenthegatecloses;aCLOSEpulse
closeswhenitopens
Thephotocellsinvertduringmotion
EN
GLIS
H
E024S 16 732642 - Rev. F
(1)ifthecyclebeganwithOPEN-B(releasedleaf),bothleavesareactivatedatopening
LOGIC “EP” PULSES
AUTOMATED SYSTEM STATUS OPEN A OPEN B STOP FSW OP FSW CL FSW CL/OP
CLOSED openstheleaves opensreleasedleaf
noeffect (OPENdisabled)
noeffect (OPENdisabled) noeffect noeffect
(OPENdisabled)
OPENING stopsoperation(1) stopsoperation stopsoperation
immediately reversesatclo-
surenoeffect
stopsandopensatrelease
(OPENstops- savesCLOSE)
OPEN reclosesleaves immediately(1)
reclosesleaves immediately
noeffect (OPEN/CLOSEdisabled)
noeffect noeffect (CLOSEdisabled)
noeffect (OPEN/CLOSEdisabled)
CLOSING stopsoperation stopsoperation stopsoperation noeffect reversesatopening
stopsandopensatrelease
(OPENstops- savesCLOSE)
BLOCKED
restartsmovinginoppositedirection.Alwaysclosesafter
STOP
restartsmovinginoppositedirection.Alwaysclosesafter
STOP
noeffect (OPEN/CLOSEdisabled)
noeffect (OPENdisabled)
noeffect (CLOSEdisabled)
noeffect (OPENstops- savesCLOSE)
LOGIC “E” PULSES
AUTOMATED SYSTEM STATUS OPEN A OPEN B STOP FSW OP FSW CL FSW CL/OP
CLOSED openstheleaves opensreleasedleaf
noeffect (OPENdisabled)
noeffect (OPENdisabled) noeffect noeffect
(OPENdisabled)
OPENING stopsoperation(1) stopsoperation stopsoperation
immediately reversesat closure
noeffectstopsandopensatrelease(OPENstops-savesCLOSE)
OPEN reclosesleaves immediately(1)
reclosesleaves immediately
noeffect (OPEN/CLOSEdisabled)
noeffect noeffect (CLOSEdisabled)
noeffect (OPEN/CLOSEdisa-
bled)
CLOSING reopensleavesimmediately
reopensleavesimmediately stopsoperation noeffect reversesatopening
stopsandopensatrelease(OPENstops-savesCLOSE)
BLOCKED closesleaves closesleavesnoeffect (OPEN/CLOSEdisabled)
noeffect (OPENdisabled)
noeffect (CLOSEdisabled)
noeffect (OPENstops- savesCLOSE)
(1)ifthecyclebeganwithOPEN-B(releasedleaf),bothleavesareactivatedatopening
(1)ifthecyclebeganwithOPEN-B(releasedleaf),bothleavesareactivatedatopening
LOGIC “AP” PULSES
AUTOMATED SYSTEM STATUS OPEN A OPEN B STOP FSW OP FSW CL FSW CL/OP
CLOSED opensandclosesafterpausetime
opensreleasedleafandclosesafterpausetime
noeffect (OPENdisabled)
noeffect (OPENdisabled) noeffect noeffect
(OPENdisabled)
OPENING stopsoperation(1) stopsoperation stopsoperation
reversesat closure(saves
OPEN)noeffect
stopsandopensatrelease
(OPENstops- savesCLOSE)
OPEN IN PAUSE stopsoperation(1) stopsoperation stopsoperation noeffect
recharges pausetime
(CLOSEdisabled)
recharges pausetime
(CLOSEdisabled)
CLOSING reopensleavesimmediately
reopensleavesimmediately stopsoperation noeffect reversesatopening
stopsandopensatrelease
(OPENstops- savesCLOSE)
BLOCKED closesleaves closesleavesnoeffect (OPEN/CLOSEdisabled)
noeffect (OPENdisabled)
noeffect (CLOSEdisabled)
noeffect (OPEN/CLOSEdisa-
bled)
EN
GLIS
H
E024S 17 732642 - Rev. F
LOGIC “C” MAINTAINED COMMANDS PULSES
AUTOMATED SYSTEM STATUS OPEN A OPEN B STOP FSW OP FSW CL FSW CL/OP
CLOSED openstheleaves noeffect noeffect (OPENdisabled)
noeffect (OPENdisabled) noeffect noeffect
(OPENdisabled)
OPENING noeffect closesleaves stopsoperation stopsoperation noeffect stopsoperation
OPEN noeffect closesleavesnoeffect (OPEN/CLOSEdisabled)
noeffect noeffect (CLOSEdisabled)
noeffect (OPEN/CLOSEdisa-
bled)
CLOSING openstheleaves noeffect stopsoperation noeffect stopsoperation stopsoperation
BLOCKED openstheleaves closesleavesnoeffect (OPEN/CLOSEdisabled)
noeffect (OPENdisabled)
noeffect (CLOSEdisabled)
noeffect (OPEN/CLOSEdisa-
bled)
LOGIC “A1” PULSES
AUTOMATED SYSTEM STATUS OPEN A OPEN B STOP FSW OP FSW CL FSW CL/OP
CLOSED opensandclosesafterpausetime
opensreleasedleafandclosesafterpausetime
noeffect (OPENdisabled)
noeffect (OPENdisabled) noeffect noeffect
(OPENdisabled)
OPENING noeffect(1) noeffect stopsoperation reversescontinues
toopenandre-closesafter5s
stopsandopensatrelease(savesCLOSE)
OPEN IN PAUSE rechargespausetime(1)
rechargespausetime(1) stopsoperation noeffect
stopsandclosesonreleaseafter
5s
recharges pausetime
(CLOSEdisabled)
CLOSING reopensleaves reopensleaves stopsoperation noeffect reversesatopening stopsandopensatrelease(savesCLOSE)
BLOCKED closesleaves closesleavesnoeffect (OPEN/CLOSEdisabled)
noeffect (OPENdisabled)
noeffect (CLOSEdisabled)
noeffect (OPEN/CLOSEdisa-
bled)
LOGIC “B” PULSES
AUTOMATED SYSTEM STATUS OPEN A OPEN B STOP FSW OP FSW CL FSW CL/OP
CLOSED openstheleaves noeffect noeffect (OPENdisabled)
noeffect (OPENdisabled) noeffect noeffect
(OPENdisabled)
OPENING noeffect stopsoperation stopsoperation stopsoperation noeffect stopsoperation
OPEN noeffect closesleavesnoeffect (OPEN/CLOSEdisabled)
noeffect noeffect (CLOSEdisabled)
noeffect (OPEN/CLOSEdisa-
bled)
CLOSING openstheleaves noeffect stopsoperation noeffect stopsoperation stopsoperation
BLOCKED openstheleaves closesleavesnoeffect (OPEN/CLOSEdisabled)
noeffect (OPENdisabled)
noeffect (CLOSEdisabled)
noeffect (OPEN/CLOSEdisa-
bled)
(1)ifthecyclebeganwithOPEN-B(releasedleaf),bothleavesareactivatedatopening
EN
GLIS
H
SEDE - HEADQUARTERSFAAC S.p.A.Via Calari, 1040069 Zola Predosa (BO) - ITALYTel. +39 051 61724 - Fax +39 051 758518www.faac.it - www.faacgroup.com
SUBSIDIARIESAUSTRIAFAAC GMBHSalzburg - Austriatel. +43 662 8533950www.faac.atFAAC TUBULAR MOTORStel. +49 30 [email protected]
AUSTRALIAFAAC AUSTRALIA PTY LTDHomebush, Sydney - Australiatel. +61 2 87565644www.faac.com.au
BENELUXFAAC BENELUX NV/SABrugge - Belgiumtel. +32 50 320202www.faacbenelux.comFAAC TUBULAR MOTORStel. +31 475 [email protected]
CHINAFAAC SHANGHAIShanghai - Chinatel. +86 21 68182970www.faacgroup.cn
FRANCEFAAC FRANCESaint Priest, Lyon - Francetel. +33 4 72218700www.faac.frFAAC FRANCE - AGENCE PARISMassy, Paris - Francetel. +33 1 69191620www.faac.frFAAC FRANCE - DEPARTEMENT VOLETSSaint Denis de Pile - Bordeaux - Francetel. +33 5 57551890www.faac.fr
ASSISTENZA IN ITALIASEDEtel. +39 051 6172501www.faac.it/ita/assistenza
FIRENZEtel. +39 055 [email protected]
GERMANYFAAC GMBHFreilassing - Germanytel. +49 8654 49810www.faac.deFAAC TUBULAR MOTORStel. +49 30 5679 [email protected]
INDIAFAAC INDIA PVT. LTDNoida, Delhi - Indiatel. +91 120 3934100/4199 www.faacindia.com
IRELANDNATIONAL AUTOMATION LIMITEDBoyle,Co. Roscommon - Irelandtel. +353 071 9663893 www.faac.ie
MIDDLE EASTFAAC MIDDLE EAST FZEDubai Silicon Oasis free zonetel. +971 4 372 4187www.faac.ae
NORDIC REGIONSFAAC NORDIC ABPerstorp - Swedentel. +46 435 779500www.faac.se
POLANDFAAC POLSKA SP.ZO.OWarszawa - Polandtel. +48 22 8141422www.faac.pl
RUSSIAFAAC RUSSIA LLCMoscow - Russiatel. +7 495 646 24 29www.faac.ru
MILANOtel +39 02 [email protected]
PADOVAtel +39 049 [email protected]
ROMAtel +39 06 [email protected]
TORINOtel +39 011 [email protected]
SPAINCLEM, S.A.U.S. S. de los Reyes, Madrid - Spaintel. +34 091 358 1110www.faac.
SWITZERLANDFAAC AGAltdorf - Switzerlandtel. +41 41 8713440www.faac.ch
TURKEYFAAC OTOMATİK GEÇİS SİSTEMLERİSAN. VE TİC. LTD. ŞTİ.Çağlayan, Kağıthane, İstanbul - Turkeytel.+90 (0)212 – 3431311www.faac.com.tr
UNITED KINGDOMFAAC UK LTD.Basingstoke, Hampshire - UKtel. +44 1256 318100www.faac.co.uk
U.S.A.FAAC INTERNATIONAL INCRockledge, Florida - U.S.A.tel. +1 904 4488952www.faacusa.comFAAC INTERNATIONAL INCFullerton, California - U.S.A.tel. +1 714 446 9800www.faacusa.com
732642 - Rev. F