E-SYNERGY RESIDENCE - Eagles Nest
Transcript of E-SYNERGY RESIDENCE - Eagles Nest
BUILDING CODE
2012 INTERNATIONAL BUILDING CODE (W/ LOCAL AMENDMENTS)2012 INTERNATIONAL RESIDENTIAL CODE (W/ LOCAL AMENDMENTS)2012 UNIFORM MECHANICAL CODE (W/ LOCAL AMENDMENTS)2012 UNIFORM PLUMBING CODE (W/ LOCAL AMENDMENTS)2011 NATIONAL ELECTRIC CODE (W/ LOCAL AMENDMENTS)2012 INTERNATIONAL ENERGY CONSERVATION CODE (W/ LOCAL AMENDMENTS)
OCCUPANCY GROUP
OCC: R-3/U-1
CONSTRUCTION
TYPE: V - N
BUILDING DEPARTMENT NOTES
EACH STRUCTURE INCLUDED IN THIS PLAN SET (BUILDINGS, FENCES, RETAINING WALLS, POOLS, ENCLOSURES, ETC.) REQUIRES A SEPARATE PERMIT AND APPLICATION. (MORE THAN ONE PERMIT MAY BE INCLUDED IN ONE SET OF PLANS)
PROJECT TEAM
STRUCTURAL ENGINEER
MECHANICAL ENGINEER
PROJECT DATA
PROJECT ADDRESS: 4049 HATCH, N. LAS VEGAS, NV. 89032APN: 139-06-411-035
AREA CALCULATIONS
VICINITY MAP
DR
AW
ING
S A
ND
SP
EC
IFIC
ATI
ON
S R
EM
AIN
TH
E P
RO
PE
RTY
OF
THE
DE
SIG
N P
RO
FES
SIO
NA
L. C
OP
IES
OF
THE
DR
AW
ING
S A
ND
SP
EC
IFIC
ATI
ON
S R
ETA
INE
D B
Y T
HE
CLI
EN
T M
AY
BE
UTI
LIZE
D O
NLY
FO
R H
IS U
SE
AN
D F
OR
OC
CU
PY
ING
TH
E P
RO
JEC
T FO
R W
HIC
H T
HE
Y W
ER
E P
RE
PA
RE
D, A
ND
NO
T FO
R T
HE
CO
NS
TRU
CTI
ON
OF
AN
Y O
THE
R P
RO
JEC
T.
SHEET NUMBER
RE
VIS
ION
S
DR
AW
ING
TIT
LE:
SEA
L
NEVADA STATE BOARD OF ARCHITECTURELICENSE # 90-P
DENNIS BEDFORDRESIDENTIAL DESIGNER7235 BERMUDA RD., SUITE GLAS VEGAS, NV 89119TEL: (702) 497-8686
DATE:
DESIGN BY:
DRAWN BY:
CHECKED BY:
D. B.
D.B.
D. B.
DA
TE
09-28-2018
IND
EX
AB
BR
EV
IAT
ION
S
LE
GE
ND
T-1.0
E-S
YN
ER
GY
RE
SID
EN
CE
404
9 H
AT
CH
ST
., N
. LA
SV
EG
AS
, N
V.
89
03
2
TIT
LE
SH
EE
T
E-SYNERGY RESIDENCE
4049 HATCH ST., N. LAS VEGAS, NV. 89032
SHEET INDEX
T-1.0 TITLE SHEET
A-1.0 SITE PLAN
A-2.0 BASEMENT - FLOOR PLAN
A-2.1 LOWER LEVEL - FLOOR PLAN
A-2.2 UPPER LEVEL - FLOOR PLAN
A-3.0 ROOF PLAN
A-4.0 EXTERIOR ELEVATION
A-4.1 EXTERIOR ELEVATION
D
UP
UP
DN
PROPERTY LINE196.96'
PROPERTY LINE196.96'
PR
OP
ER
TY
LIN
E1
03
.57
'
104
.1'
PR
OP
ER
TY
LIN
E
SAN JUAN AVE.
404
9 H
AT
CH
ST
.
SID
E S
ET
BA
CK
15
' -
0"
FRONT SETBACK
20' - 0"
SID
E S
ET
BA
CK
10
' -
0"
REAR SETBACK
20' - 0"
15
' -
0"
DRIVEWAY
WA
LK
WA
Y
DR
AW
ING
S A
ND
SP
EC
IFIC
ATI
ON
S R
EM
AIN
TH
E P
RO
PE
RTY
OF
THE
DE
SIG
N P
RO
FES
SIO
NA
L. C
OP
IES
OF
THE
DR
AW
ING
S A
ND
SP
EC
IFIC
ATI
ON
S R
ETA
INE
D B
Y T
HE
CLI
EN
T M
AY
BE
UTI
LIZE
D O
NLY
FO
R H
IS U
SE
AN
D F
OR
OC
CU
PY
ING
TH
E P
RO
JEC
T FO
R W
HIC
H T
HE
Y W
ER
E P
RE
PA
RE
D, A
ND
NO
T FO
R T
HE
CO
NS
TRU
CTI
ON
OF
AN
Y O
THE
R P
RO
JEC
T.
SHEET NUMBER
RE
VIS
ION
S
DR
AW
ING
TIT
LE
:
SE
AL
NEVADA STATE BOARD OF ARCHITECTURELICENSE # 90-P
DENNIS BEDFORDRESIDENTIAL DESIGNER320 E. WARM SPRINGS, SUITE # 2ALAS VEGAS, NV 89119TEL: (702) 497-8686
DATE:
DESIGN BY:
DRAWN BY:
CHECKED BY:
D. B.
D.B.
D. B.
DA
TE
Keyno
tes
Ge
ne
ral N
ote
s
3/19/2020 9:32:07 AM
A-1.0
E-S
YN
ER
GY
RE
SID
EN
CE
404
9 H
AT
CH
ST
., N
. LA
SV
EG
AS
, N
V.
89
03
2
SIT
E P
LA
N
1/8" = 1'-0"1SITE PLAN
NO
RT
H
UP
UP
DN
DN
REF.
DN
DN
GENERAL NOTES
1. NOT ALL KEYNOTES MAY APPLY.
2. SLEEPING ROOMS SHALL HAVE A WINDOW OR EXTERIOR DOOR FOR EMERGENCY ESCAPE. SILL HEIGHT SHALL NOT EXCEED 44" ABOVE THE FINISHED FLOOR. WINDOWS MUST HAVE AN OPENABLE AREA OF AT LEAST 5.7 SQ FT WITH THE MINIMUM OPENABLE WIDTH OF 20" AND THE MINIMUM OPENABLE HEIGHT OF 24". THE EMERGENCY DOOR OR WINDOW SHALL BE OPENABLE FROM THE INSIDE TO PROVIDE A FULL, CLEAR OPENING WITHOUT THE USE OF SEPARATE TOOLS (I.R.C. R310.1).
3. SHOWERS SHALL BE CONSTRUCTED IN ACCORDANCE WITH (U.P.C. 411.0)
4. ALL NEW GLAZING WILL BE INSTALLED WITH A CERTIFYING LABEL ATTACHED SHOWING THE U-VALUE.
5. ALL GLAZING SHALL COMPLY WITH I.R.C. AND LOCAL ORDINANCES. REFER TO THE ENERGY COMPLIANCE STATEMENT FOR ALL GLAZING REQUIREMENTS.
6. WINDOWS ADJACENT TO TUBS, SHOWERS AND TUB/SHOWERS, STAIRWAYS OR ADJACENT TO AND WITH 24" OF EITHER EDGE OF DOOR SHALL BE FULLY TEMPERED, LAMINATED SAFETY GLASS OR APPROVED PLASTIC PER I.R.C. GLASS TO BE ETCHED.
7. ALL EXTERIOR DOORS OF CONDITIONED SPACES SHALL BE FULLY WEATHER STRIPPED.
8. PROVIDE INSULATION EQUAL TO R-13 IN EXTERIOR WALLS AND R-38 IN ATTIC. ATTIC INSULATION TO BE FILLED TO TOP OF SHEATHING IN FLAT ROOF CONDITIONS. NOT ATTIC TO VENT IN THOSE CONDITIONS. VERIFY WITH ENERGY COMPLIANCE STATEMENT.
9. PROVIDE A MINIMUM OF 10 MIL. VAPOR BARRIER UNDER ALL POURED IN PLACE CONCRETE FLOOR SLAB WHERE SLAB SERVES AS THE FLOOR FOR INTERIOR ENVIRONMENT.
10. THE STREET ADDRESS SHALL BE POSTED ON THE BUILDING IN SUCH A POSITION TO BE PLAINLY LEGIBLE FROM THE STREET FRONTING THE PROPERTY AND MUST BE ILLUMINATED.
11. WHEN THERE IS USABLE SPACE BOTH ABOVE AND BELOW THE CONCEALED SPACE OF A FLOOR/ CEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1,000 SQUARE FEET. DRAFTSTOPPING SHALL DIVIDE THE CONCEALED SPACE INTO APPROXIMATE EQUAL AREAS. WHERE THE ASSEMBLY IS ENCLOSED BY A FLOOR MEMBRANE ABOVE AND A CEILING MEMBRANE BELOW DRAFTSTOPPING SHALL BE PROVIDED IN FLOOR/ CEILING ASSEMBLIES UNDER THE FOLLOWING CONDITIONS (I.R.C. R502.12).11.1. CEILING IS SUSPENDED UNDER THE FLOOR FRAMING.11.2. FLOOR FRAMING IS CONSTRUCTED OF TRUSS-TYPE OPEN WEB OR PERFORATED MEMBERS.
12. FIREBLOCKING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND HORIZONTAL) AND TO FORM AN EFFECTIVE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY AND A ROOF SPACE. FIREBLOCKING SHALL BE PROVIDED IN WOOD FRAME CONSTRUCTION IN THE FOLLOWING LOCATION IN ACCORDANCE WITH I.R.C. R602.8:12.1. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES & PARALLEL ROWS OF STUDS OR STAGGERED STUDS; AS FOLLOWS:12.1.1. VERTICALLY AT THE CEILING AND FLOOR LEVELS12.1.2. HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FEET12.2. AT ALL INTERCONNECTIONS BETWEEN CONCEALED, VERTICAL AND HORIZONTAL SPACES SUCH AS THOSE THAT OCCUR AT SOFFITS, DROPPED CEILING AND COVE CEILINGS.12.3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN.12.4. AT OPENINGS AROUND VENTS, PIPES, AND DUCTS AT CEILING AND FLOOR LEVEL, WITH AN APPROVED MATERIAL TO RESIST THE FREE PASSAGE OF FLAME AND PRODUCTS OF COMBUSTION.12.5. FOR THE FIREBLOCKING OF CHIMNEYS AND FIREPLACES, COMPLY WITH (I.R.C. R1003.19).
13. FACTORY BUILT FIREPLACES WHICH HAVE A LISTED AND LABLED GAS LOG SHAL MEET THE STANDARDS AND ARE INSTALLED IN ACCORDANCE WITH THE MFR'S INSTALLATION INSTRUCTIONS. THE FIREPLACE OPENING SHALL BE COMPLETELY ENCLOSED WITH A COVER OF SOLID GLASS, STEEL, OR CAST IRON. THE COVERING MAY EITHER BE SOLID OR OPERABLE. A CAUTION SIGN SHALL BE PERMANTLY BE INSTALLED AND MAINTAINED WHERE IT IS READILY VISIBLE AT ALL TIMES. THE SIGN SHALL STATE: "CAUTION APPROVED FORFUEL GAS ONLY. DAMPER SHALL BE PERMANENTLY BLOCKED OPEN." THE LETTERS ON THE SIGN SHALL BE A MIN. OF 3/8" IN HEIGHT. (R1007.1 AS AMENDED)14. SKYLIGHTS SHALL COMPLY WITH (I.R.C. R308.6).
15. WHERE 1/2" GYPSUM BOARD IS INSTALLED ON CEILINGS FRAMED AT 24" ON CENTER AND WHERE WATER-BASED TEXTURE FINISH IS TO BE APPLIED, OR WHERE IT WILL BE REQUIRED TO SUPPORT INSULATION ABOVE A CEILING, THE 1/2" GYPSUM BOARD SHALL BE SAG RESISTANT CEILING OR INCREASED TO 5/8" GYPSUM BOARD. (I.R.C. TABLE R 702.3.5)
16. UNLESS OTHERWISE PERMITTED BY I.R.C. R314.5 OR R314.6, FOAM PLASTIC SHALL BE SEPARATED FROM THE INTERIOR OF A BUILDING BY AN APPROVED THERMAL BARRIER OF A MINIMUM 1/2" GYPSUM WALL BOARD OR AN APPROVED FINISH MATERIAL EQUIVALENT TO A THERMAL BARRIER MATERIAL (I.R.C. R314.4).
BEDROOM
#4
CLG 9' 1"
CLOSET
CLG 9' - 1"CLOSET
CLG 9' - 1"
BATH #4
CLG 9' - 1"
BATH #5
CLG 9' - 1"
BEDROOM
#5
CLG 9' - 1" EXERCISE
CLG 9' - 1"
DANCE
CLG 9' - 1"
THEATRE
CLG 9' - 1"
SAFE
ROOM /
EQ
CLG 9' - 1"
POWDER
CLG 9' - 1"
MULTI-PURPOSE
CLG 9' - 1"COVERED
PATIO
CLG 9' - 1"
14' - 11 1/2" 24' - 5" 11' - 3 1/2" 9' - 3" 8' - 7 1/2" 15' - 4 1/2"
5' - 4" 17' - 9" 8' - 3 1/2" 8' - 3 1/2" 12' - 5 1/2" 17' - 3 1/2" 19' - 10"
83' - 11"
7' -
4"
21
' -
7 1
/2"
5' -
8 1
/2"
16
' -
5 1
/2"
5' -
4"
51
' -
1 1
/2"
17' - 11" 5' - 5" 17' - 10" 17' - 6 1/2" 6' - 3" 5' - 1"
9' - 6" 9' - 6"
83' - 11"
7' -
1"
17
' -
0"
5' -
4 1
/2"
7' -
0"
14
' -
8"
5' -
4"
29
' -
6"
21
' -
8"
51
' -
1 1
/2"5' - 4 1/2" 3' - 9" 4' - 1 1/2" 3' - 4" 6' - 2 1/2" 6' - 3" 17' - 3 1/2"
14
' -
2 1
/2"
7' -
11
1/2
"
29
' -
0"
70' - 0" 13' - 11"
1.11.0
1.3 1.31.0
1.1
5.7
5.7
5.7
7' -
4"
22
' -
2"
1.1
1.0
4.5
1
2
3
4
5
7
8
9
12 13
14
15
1 2 3 4
16
6
7
17
44
64
ELEV
OPEN
POWDER
CLG 9' - 1"
1.0
1.1
79 80 81
STORAGE
CLG 9' - 1"
MECHANICAL
CLG 9' - 1"
82
STORAGE
CLG 9' - 1"
19' - 0"
KITCHEN
CLG 9' - 1"
87
885.7
90
91
5.7
CLOSET
CLG 9' - 1"
5.7
DR
AW
ING
S A
ND
SP
EC
IFIC
ATI
ON
S R
EM
AIN
TH
E P
RO
PE
RTY
OF
THE
DE
SIG
N P
RO
FES
SIO
NA
L. C
OP
IES
OF
THE
DR
AW
ING
S A
ND
SP
EC
IFIC
ATI
ON
S R
ETA
INE
D B
Y T
HE
CLI
EN
T M
AY
BE
UTI
LIZE
D O
NLY
FO
R H
IS U
SE
AN
D F
OR
OC
CU
PY
ING
TH
E P
RO
JEC
T FO
R W
HIC
H T
HE
Y W
ER
E P
RE
PA
RE
D, A
ND
NO
T FO
R T
HE
CO
NS
TRU
CTI
ON
OF
AN
Y O
THE
R P
RO
JEC
T.
SHEET NUMBER
RE
VIS
ION
S
DR
AW
ING
TIT
LE
:
SE
AL
NEVADA STATE BOARD OF ARCHITECTURELICENSE # 90-P
DENNIS BEDFORDRESIDENTIAL DESIGNER320 E. WARM SPRINGS, SUITE # 2ALAS VEGAS, NV 89119TEL: (702) 497-8686
DATE:
DESIGN BY:
DRAWN BY:
CHECKED BY:
D. B.
D.B.
D. B.
DA
TE
Keyno
tes
Ge
ne
ral N
ote
s
3/19/2020 9:32:15 AM
A-2.0
E-S
YN
ER
GY
RE
SID
EN
CE
404
9 H
AT
CH
ST
., N
. LA
SV
EG
AS
, N
V.
89
03
2
BA
SE
ME
NT
-F
LO
OR
PL
AN
FLOOR PLAN - KEYNOTES
1.0 WATER CLOSET W/ 30" WIDE X 24" DEEP CLEAR SPACE CENTEREDON FRONT OF FIXTURE (I.R.C. R307) COMPLY W/UPC
1.1 LAVATORY - VERIFY DIM. W/ MFR. SPEC.
1.3 TUB/SHOWER COMBINATION W/ WAINSCOT TO 72" MIN. ABOVEDRAIN OVER DENSHIELD OR EQUAL FIBER CEMENT BACKERBOARD. VERIFY DIM. W/ MFR. SPEC.
1.4 SHOWER W/ WAINSCOT TO CLG. ABOVE DRAIN OVER DENSHIELDOR EQUAL FIBER CEMENT BACKER BOARD. VERIFY DIMS. W/ MFR.SPEC. TEMPERED GLAZING @ ENCLOSURE.
1.5 FREESTANDING TUB - VERIFY DIM. W/ MFR. SPEC. INSTALL PERMFR SPEC. PROVIDE CEILING FILLER.
2.0 KITCHEN SINK W/ GARBAGE DISPOSAL - VERIFY DIM. W/ MFR SPEC./R.O. WATER
2.1 DISHWASHER - PROVIDE SURFACE MOUNT AIR GAP - VERIFY DIM.W/ MFR. SPEC.
2.3 36" H. BASE CAB. W/ UPPER CABINETS PER PLAN.
4.0 WASHER SPACE: PROVIDE WATER CONTROL VALVES AND WASTERECESSED IN WALL. TOP OF BOX AT +42" A.F.F.
4.1 DRYER SPACE: PROVIDED SMOOTH METAL DRYER VENT DUCT TOOUTSIDE WITH BACKDRAFT DAMPER 4" DIA. AND 14' MAX. LENGTHWITH 2 ELBOWS MAX. (U.M.C. 504.3.2.1)
4.4 PANTRY SHELVES.
4.5 (5) SHELVES.
4.8 GAS FIRE PLACE APPLIANC, WOODLAND DIRECT: SUPERIO RDRC2000 DIRECT VENT UL LISTED AND 1721.88.
5.7 ROD & SHELF
13.1 5/8" TYPE 'X' GYP BD @ WALLS & CLG R302.5.1, R302.6.
16.4 42" H. RAILING: GUARDRAIL OPENING LIMITATIONS. REQ. GUARDSON OPEN SIDES OF STAIRWAYS, RAISED FLOOR AREAS, BALCONESAND PORCHES SHALL HAVE INTERMEDIATE RAILS ORORNAMENTAL CLOSURES WICH DO NOT ALLOW PASSAGE OF ASPHERE 4" OR MORE IN DIAMETER.
3/16" = 1'-0"1BASEMENT
UP
D W
DN
UP
GENERAL NOTES
1. NOT ALL KEYNOTES MAY APPLY.
2. SLEEPING ROOMS SHALL HAVE A WINDOW OR EXTERIOR DOOR FOR EMERGENCY ESCAPE. SILL HEIGHT SHALL NOT EXCEED 44" ABOVE THE FINISHED FLOOR. WINDOWS MUST HAVE AN OPENABLE AREA OF AT LEAST 5.7 SQ FT WITH THE MINIMUM OPENABLE WIDTH OF 20" AND THE MINIMUM OPENABLE HEIGHT OF 24". THE EMERGENCY DOOR OR WINDOW SHALL BE OPENABLE FROM THE INSIDE TO PROVIDE A FULL, CLEAR OPENING WITHOUT THE USE OF SEPARATE TOOLS (I.R.C. R310.1).
3. SHOWERS SHALL BE CONSTRUCTED IN ACCORDANCE WITH (U.P.C. 411.0)
4. ALL NEW GLAZING WILL BE INSTALLED WITH A CERTIFYING LABEL ATTACHED SHOWING THE U-VALUE.
5. ALL GLAZING SHALL COMPLY WITH I.R.C. AND LOCAL ORDINANCES. REFER TO THE ENERGY COMPLIANCE STATEMENT FOR ALL GLAZING REQUIREMENTS.
6. WINDOWS ADJACENT TO TUBS, SHOWERS AND TUB/SHOWERS, STAIRWAYS OR ADJACENT TO AND WITH 24" OF EITHER EDGE OF DOOR SHALL BE FULLY TEMPERED, LAMINATED SAFETY GLASS OR APPROVED PLASTIC PER I.R.C. GLASS TO BE ETCHED.
7. ALL EXTERIOR DOORS OF CONDITIONED SPACES SHALL BE FULLY WEATHER STRIPPED.
8. PROVIDE INSULATION EQUAL TO R-13 IN EXTERIOR WALLS AND R-38 IN ATTIC. ATTIC INSULATION TO BE FILLED TO TOP OF SHEATHING IN FLAT ROOF CONDITIONS. NOT ATTIC TO VENT IN THOSE CONDITIONS. VERIFY WITH ENERGY COMPLIANCE STATEMENT.
9. PROVIDE A MINIMUM OF 10 MIL. VAPOR BARRIER UNDER ALL POURED IN PLACE CONCRETE FLOOR SLAB WHERE SLAB SERVES AS THE FLOOR FOR INTERIOR ENVIRONMENT.
10. THE STREET ADDRESS SHALL BE POSTED ON THE BUILDING IN SUCH A POSITION TO BE PLAINLY LEGIBLE FROM THE STREET FRONTING THE PROPERTY AND MUST BE ILLUMINATED.
11. WHEN THERE IS USABLE SPACE BOTH ABOVE AND BELOW THE CONCEALED SPACE OF A FLOOR/ CEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1,000 SQUARE FEET. DRAFTSTOPPING SHALL DIVIDE THE CONCEALED SPACE INTO APPROXIMATE EQUAL AREAS. WHERE THE ASSEMBLY IS ENCLOSED BY A FLOOR MEMBRANE ABOVE AND A CEILING MEMBRANE BELOW DRAFTSTOPPING SHALL BE PROVIDED IN FLOOR/ CEILING ASSEMBLIES UNDER THE FOLLOWING CONDITIONS (I.R.C. R502.12).11.1. CEILING IS SUSPENDED UNDER THE FLOOR FRAMING.11.2. FLOOR FRAMING IS CONSTRUCTED OF TRUSS-TYPE OPEN WEB OR PERFORATED MEMBERS.
12. FIREBLOCKING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND HORIZONTAL) AND TO FORM AN EFFECTIVE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY AND A ROOF SPACE. FIREBLOCKING SHALL BE PROVIDED IN WOOD FRAME CONSTRUCTION IN THE FOLLOWING LOCATION IN ACCORDANCE WITH I.R.C. R602.8:12.1. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES & PARALLEL ROWS OF STUDS OR STAGGERED STUDS; AS FOLLOWS:12.1.1. VERTICALLY AT THE CEILING AND FLOOR LEVELS12.1.2. HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FEET12.2. AT ALL INTERCONNECTIONS BETWEEN CONCEALED, VERTICAL AND HORIZONTAL SPACES SUCH AS THOSE THAT OCCUR AT SOFFITS, DROPPED CEILING AND COVE CEILINGS.12.3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN.12.4. AT OPENINGS AROUND VENTS, PIPES, AND DUCTS AT CEILING AND FLOOR LEVEL, WITH AN APPROVED MATERIAL TO RESIST THE FREE PASSAGE OF FLAME AND PRODUCTS OF COMBUSTION.12.5. FOR THE FIREBLOCKING OF CHIMNEYS AND FIREPLACES, COMPLY WITH (I.R.C. R1003.19).
13. FACTORY BUILT FIREPLACES WHICH HAVE A LISTED AND LABLED GAS LOG SHAL MEET THE STANDARDS AND ARE INSTALLED IN ACCORDANCE WITH THE MFR'S INSTALLATION INSTRUCTIONS. THE FIREPLACE OPENING SHALL BE COMPLETELY ENCLOSED WITH A COVER OF SOLID GLASS, STEEL, OR CAST IRON. THE COVERING MAY EITHER BE SOLID OR OPERABLE. A CAUTION SIGN SHALL BE PERMANTLY BE INSTALLED AND MAINTAINED WHERE IT IS READILY VISIBLE AT ALL TIMES. THE SIGN SHALL STATE: "CAUTION APPROVED FORFUEL GAS ONLY. DAMPER SHALL BE PERMANENTLY BLOCKED OPEN." THE LETTERS ON THE SIGN SHALL BE A MIN. OF 3/8" IN HEIGHT. (R1007.1 AS AMENDED)14. SKYLIGHTS SHALL COMPLY WITH (I.R.C. R308.6).
15. WHERE 1/2" GYPSUM BOARD IS INSTALLED ON CEILINGS FRAMED AT 24" ON CENTER AND WHERE WATER-BASED TEXTURE FINISH IS TO BE APPLIED, OR WHERE IT WILL BE REQUIRED TO SUPPORT INSULATION ABOVE A CEILING, THE 1/2" GYPSUM BOARD SHALL BE SAG RESISTANT CEILING OR INCREASED TO 5/8" GYPSUM BOARD. (I.R.C. TABLE R 702.3.5)
16. UNLESS OTHERWISE PERMITTED BY I.R.C. R314.5 OR R314.6, FOAM PLASTIC SHALL BE SEPARATED FROM THE INTERIOR OF A BUILDING BY AN APPROVED THERMAL BARRIER OF A MINIMUM 1/2" GYPSUM WALL BOARD OR AN APPROVED FINISH MATERIAL EQUIVALENT TO A THERMAL BARRIER MATERIAL (I.R.C. R314.4).
CRAFT /
LAUNDRY
CLG 10' - 1"
W. I. C.
CLG 10' - 1"
W. I. C.
CLG 10' - 1"
CLOSET
CLG 10' - 1"
POWDER
CLG 10' - 1"
ENTRY
CLG 10' - 1"
GREAT
ROOM
CLG 10' - 1"
OFFICE
CLG 10' - 1"
CLOSET
CLG 10' - 1" POWDER
CLG 10' - 1"
POWDER
CLG 10' - 1"
PANTRY
CLG 10' - 1"
WALK-IN
COOLER
CLG 10' - 1"
WALK-IN
FREEZER
CLG 10' - 1"
KITCHEN
CLG 10' - 1"
DINING
CLG 10' - 1"
DECK
VAULTED CEILING
RV/
MULTI
PURPOSE
CLG 15' - 1"
SITTING
CLG 10' - 1"
MASTER
BEDROOM
CLG 10' - 1"
M/ BATH
CLG 10' - 1"
6' -
9"
13
' -
7"
20
' -
0"
12
' -
3"
14
' -
0 1
/2"
67' - 0 1/2" 13' - 0" 3' - 10 1/2"
12' - 5" 5' - 4" 47' - 0" 19' - 2"
5' - 4" 5' - 4 1/2" 7' - 8 1/2"
11
' -
1 1
/2"
11
' -
0 1
/2"
29
' -
6"
10
' -
7 1
/2"
14
' -
1"
6' -
6 1
/2"
7' - 6 1/2" 5' - 2 1/2" 5' - 4 1/2" 3' - 9" 4' - 1 1/2" 5' - 2 1/2" 31' - 6 1/2" 16' - 2"
3' - 7" 21' - 1" 21' - 9 1/2"
5' - 9 1/2" 5' - 4 1/2" 14' - 6" 5' - 0" 10' - 4 1/2" 11' - 11"
27
' -
0"
7' -
1"
15
' -
1"
6' -
7 1
/2"
6' -
5"
10
' - 1
1"
5' -
6 1
/2"
0' - 8"
0' -
8"
12
' - 1
1"
0' -
8"
7' -
0"
35
' -
5"
6' -
9 1
/2"
4' -
11
1/2
"1
1' -
0 1
/2"
13
' -
6"
28
' -
6 1
/2"
5' -
2 1
/2"
15
' -
5 1
/2"
29
' -
6"
18
19 20
21 22
23
24
26 2728
31
1112
32
33
34
35
36
37
39
40
42
43
13
45
14 15
47
48
65
23
24
25
4.04.12.3
4.5
5.7
5.7
1.1
1.11.0
1.4 1.5
5.7
2.0
2.3
4.5
4.54.4
16.4
13.11.0
1.1
5.7
67
SAFE
CLG 10' - 1"
1.0
1.113.1
69
19' - 0"
1.0 1.1
4.572
2.3
ELEV.
OPEN
1.0
7' -
10
1/2
"6
' -
0"
8' -
3 1
/2"
16' - 6"
19' - 0"
2.1
4.8
10' - 3 1/2" 14' - 0" 14' - 0" 14' - 0" 14' - 0" 15' - 7"
81' - 11"
78
' -
8"
40
27
' -
0"
51
' -
8"
78
' -
8"
83' - 11"
83
48
47
3' -
3 1
/2"
7' -
9 1
/2"
4' -
9 1
/2"
5' -
0 1
/2"
5.7 5.7
5.7
86
55 57 59 61
75
12' - 5 1/2" 5' - 2 1/2" 2' - 3"
DR
AW
ING
S A
ND
SP
EC
IFIC
ATI
ON
S R
EM
AIN
TH
E P
RO
PE
RTY
OF
THE
DE
SIG
N P
RO
FES
SIO
NA
L. C
OP
IES
OF
THE
DR
AW
ING
S A
ND
SP
EC
IFIC
ATI
ON
S R
ETA
INE
D B
Y T
HE
CLI
EN
T M
AY
BE
UTI
LIZE
D O
NLY
FO
R H
IS U
SE
AN
D F
OR
OC
CU
PY
ING
TH
E P
RO
JEC
T FO
R W
HIC
H T
HE
Y W
ER
E P
RE
PA
RE
D, A
ND
NO
T FO
R T
HE
CO
NS
TRU
CTI
ON
OF
AN
Y O
THE
R P
RO
JEC
T.
SHEET NUMBER
RE
VIS
ION
S
DR
AW
ING
TIT
LE
:
SE
AL
NEVADA STATE BOARD OF ARCHITECTURELICENSE # 90-P
DENNIS BEDFORDRESIDENTIAL DESIGNER320 E. WARM SPRINGS, SUITE # 2ALAS VEGAS, NV 89119TEL: (702) 497-8686
DATE:
DESIGN BY:
DRAWN BY:
CHECKED BY:
D. B.
D.B.
D. B.
DA
TE
Keyno
tes
Ge
ne
ral N
ote
s
3/19/2020 9:32:22 AM
A-2.1
E-S
YN
ER
GY
RE
SID
EN
CE
404
9 H
AT
CH
ST
., N
. LA
SV
EG
AS
, N
V.
89
03
2
LO
WE
R L
EV
EL
-F
LO
OR
PL
AN
3/16" = 1'-0"1LOWER LEVEL
FLOOR PLAN - KEYNOTES
1.0 WATER CLOSET W/ 30" WIDE X 24" DEEP CLEAR SPACE CENTEREDON FRONT OF FIXTURE (I.R.C. R307) COMPLY W/UPC
1.1 LAVATORY - VERIFY DIM. W/ MFR. SPEC.
1.3 TUB/SHOWER COMBINATION W/ WAINSCOT TO 72" MIN. ABOVEDRAIN OVER DENSHIELD OR EQUAL FIBER CEMENT BACKERBOARD. VERIFY DIM. W/ MFR. SPEC.
1.4 SHOWER W/ WAINSCOT TO CLG. ABOVE DRAIN OVER DENSHIELDOR EQUAL FIBER CEMENT BACKER BOARD. VERIFY DIMS. W/ MFR.SPEC. TEMPERED GLAZING @ ENCLOSURE.
1.5 FREESTANDING TUB - VERIFY DIM. W/ MFR. SPEC. INSTALL PERMFR SPEC. PROVIDE CEILING FILLER.
2.0 KITCHEN SINK W/ GARBAGE DISPOSAL - VERIFY DIM. W/ MFR SPEC./R.O. WATER
2.1 DISHWASHER - PROVIDE SURFACE MOUNT AIR GAP - VERIFY DIM.W/ MFR. SPEC.
2.3 36" H. BASE CAB. W/ UPPER CABINETS PER PLAN.
4.0 WASHER SPACE: PROVIDE WATER CONTROL VALVES AND WASTERECESSED IN WALL. TOP OF BOX AT +42" A.F.F.
4.1 DRYER SPACE: PROVIDED SMOOTH METAL DRYER VENT DUCT TOOUTSIDE WITH BACKDRAFT DAMPER 4" DIA. AND 14' MAX. LENGTHWITH 2 ELBOWS MAX. (U.M.C. 504.3.2.1)
4.4 PANTRY SHELVES.
4.5 (5) SHELVES.
4.8 GAS FIRE PLACE APPLIANC, WOODLAND DIRECT: SUPERIO RDRC2000 DIRECT VENT UL LISTED AND 1721.88.
5.7 ROD & SHELF
13.1 5/8" TYPE 'X' GYP BD @ WALLS & CLG R302.5.1, R302.6.
16.4 42" H. RAILING: GUARDRAIL OPENING LIMITATIONS. REQ. GUARDSON OPEN SIDES OF STAIRWAYS, RAISED FLOOR AREAS, BALCONESAND PORCHES SHALL HAVE INTERMEDIATE RAILS ORORNAMENTAL CLOSURES WICH DO NOT ALLOW PASSAGE OF ASPHERE 4" OR MORE IN DIAMETER.
DN
GENERAL NOTES
1. NOT ALL KEYNOTES MAY APPLY.
2. SLEEPING ROOMS SHALL HAVE A WINDOW OR EXTERIOR DOOR FOR EMERGENCY ESCAPE. SILL HEIGHT SHALL NOT EXCEED 44" ABOVE THE FINISHED FLOOR. WINDOWS MUST HAVE AN OPENABLE AREA OF AT LEAST 5.7 SQ FT WITH THE MINIMUM OPENABLE WIDTH OF 20" AND THE MINIMUM OPENABLE HEIGHT OF 24". THE EMERGENCY DOOR OR WINDOW SHALL BE OPENABLE FROM THE INSIDE TO PROVIDE A FULL, CLEAR OPENING WITHOUT THE USE OF SEPARATE TOOLS (I.R.C. R310.1).
3. SHOWERS SHALL BE CONSTRUCTED IN ACCORDANCE WITH (U.P.C. 411.0)
4. ALL NEW GLAZING WILL BE INSTALLED WITH A CERTIFYING LABEL ATTACHED SHOWING THE U-VALUE.
5. ALL GLAZING SHALL COMPLY WITH I.R.C. AND LOCAL ORDINANCES. REFER TO THE ENERGY COMPLIANCE STATEMENT FOR ALL GLAZING REQUIREMENTS.
6. WINDOWS ADJACENT TO TUBS, SHOWERS AND TUB/SHOWERS, STAIRWAYS OR ADJACENT TO AND WITH 24" OF EITHER EDGE OF DOOR SHALL BE FULLY TEMPERED, LAMINATED SAFETY GLASS OR APPROVED PLASTIC PER I.R.C. GLASS TO BE ETCHED.
7. ALL EXTERIOR DOORS OF CONDITIONED SPACES SHALL BE FULLY WEATHER STRIPPED.
8. PROVIDE INSULATION EQUAL TO R-13 IN EXTERIOR WALLS AND R-38 IN ATTIC. ATTIC INSULATION TO BE FILLED TO TOP OF SHEATHING IN FLAT ROOF CONDITIONS. NOT ATTIC TO VENT IN THOSE CONDITIONS. VERIFY WITH ENERGY COMPLIANCE STATEMENT.
9. PROVIDE A MINIMUM OF 10 MIL. VAPOR BARRIER UNDER ALL POURED IN PLACE CONCRETE FLOOR SLAB WHERE SLAB SERVES AS THE FLOOR FOR INTERIOR ENVIRONMENT.
10. THE STREET ADDRESS SHALL BE POSTED ON THE BUILDING IN SUCH A POSITION TO BE PLAINLY LEGIBLE FROM THE STREET FRONTING THE PROPERTY AND MUST BE ILLUMINATED.
11. WHEN THERE IS USABLE SPACE BOTH ABOVE AND BELOW THE CONCEALED SPACE OF A FLOOR/ CEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1,000 SQUARE FEET. DRAFTSTOPPING SHALL DIVIDE THE CONCEALED SPACE INTO APPROXIMATE EQUAL AREAS. WHERE THE ASSEMBLY IS ENCLOSED BY A FLOOR MEMBRANE ABOVE AND A CEILING MEMBRANE BELOW DRAFTSTOPPING SHALL BE PROVIDED IN FLOOR/ CEILING ASSEMBLIES UNDER THE FOLLOWING CONDITIONS (I.R.C. R502.12).11.1. CEILING IS SUSPENDED UNDER THE FLOOR FRAMING.11.2. FLOOR FRAMING IS CONSTRUCTED OF TRUSS-TYPE OPEN WEB OR PERFORATED MEMBERS.
12. FIREBLOCKING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND HORIZONTAL) AND TO FORM AN EFFECTIVE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY AND A ROOF SPACE. FIREBLOCKING SHALL BE PROVIDED IN WOOD FRAME CONSTRUCTION IN THE FOLLOWING LOCATION IN ACCORDANCE WITH I.R.C. R602.8:12.1. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES & PARALLEL ROWS OF STUDS OR STAGGERED STUDS; AS FOLLOWS:12.1.1. VERTICALLY AT THE CEILING AND FLOOR LEVELS12.1.2. HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FEET12.2. AT ALL INTERCONNECTIONS BETWEEN CONCEALED, VERTICAL AND HORIZONTAL SPACES SUCH AS THOSE THAT OCCUR AT SOFFITS, DROPPED CEILING AND COVE CEILINGS.12.3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN.12.4. AT OPENINGS AROUND VENTS, PIPES, AND DUCTS AT CEILING AND FLOOR LEVEL, WITH AN APPROVED MATERIAL TO RESIST THE FREE PASSAGE OF FLAME AND PRODUCTS OF COMBUSTION.12.5. FOR THE FIREBLOCKING OF CHIMNEYS AND FIREPLACES, COMPLY WITH (I.R.C. R1003.19).
13. FACTORY BUILT FIREPLACES WHICH HAVE A LISTED AND LABLED GAS LOG SHAL MEET THE STANDARDS AND ARE INSTALLED IN ACCORDANCE WITH THE MFR'S INSTALLATION INSTRUCTIONS. THE FIREPLACE OPENING SHALL BE COMPLETELY ENCLOSED WITH A COVER OF SOLID GLASS, STEEL, OR CAST IRON. THE COVERING MAY EITHER BE SOLID OR OPERABLE. A CAUTION SIGN SHALL BE PERMANTLY BE INSTALLED AND MAINTAINED WHERE IT IS READILY VISIBLE AT ALL TIMES. THE SIGN SHALL STATE: "CAUTION APPROVED FORFUEL GAS ONLY. DAMPER SHALL BE PERMANENTLY BLOCKED OPEN." THE LETTERS ON THE SIGN SHALL BE A MIN. OF 3/8" IN HEIGHT. (R1007.1 AS AMENDED)14. SKYLIGHTS SHALL COMPLY WITH (I.R.C. R308.6).
15. WHERE 1/2" GYPSUM BOARD IS INSTALLED ON CEILINGS FRAMED AT 24" ON CENTER AND WHERE WATER-BASED TEXTURE FINISH IS TO BE APPLIED, OR WHERE IT WILL BE REQUIRED TO SUPPORT INSULATION ABOVE A CEILING, THE 1/2" GYPSUM BOARD SHALL BE SAG RESISTANT CEILING OR INCREASED TO 5/8" GYPSUM BOARD. (I.R.C. TABLE R 702.3.5)
16. UNLESS OTHERWISE PERMITTED BY I.R.C. R314.5 OR R314.6, FOAM PLASTIC SHALL BE SEPARATED FROM THE INTERIOR OF A BUILDING BY AN APPROVED THERMAL BARRIER OF A MINIMUM 1/2" GYPSUM WALL BOARD OR AN APPROVED FINISH MATERIAL EQUIVALENT TO A THERMAL BARRIER MATERIAL (I.R.C. R314.4).
STORAGE
SLOPED CEILING
STORAGE
CLG 10' - 1"
STORAGE
SLOPED CEILING
COMMON
AREA
VAULTED CEILING
BEDROOM
#3
VAULTED CEILING
CLOSET
CLG 10' - 1"
BATH #3
VAULTED CEILINGMASTER
CLOSET
VAULTED CEILING
MASTER
BATH
VAULTED CEILING
MASTER
BEDROOM
#2
VAULTED CEILING
DECK
OPEN
5.7
4.5
1.11.0
1.3
5.7
1.1 1.1
1.4 1.51.0
5.7
16
49
50
51
52
53
54
55
57
58
59
20
21
6162 63
22
6' -
3 1
/2"
12
' -
1 1
/2"
12
' -
2 1
/2"
13
' - 1
0"
6' -
8 1
/2"
11
' -
2"
14
' -
7"
18
' -
8 1
/2"
22' - 0"
83' - 11"
12' - 4 1/2" 10' - 9" 7' - 8 1/2" 12' - 9 1/2" 10' - 0" 6' - 3 1/2" 24' - 0"
31' - 2" 26' - 1 1/2" 26' - 7 1/2"
28' - 1 1/2" 15' - 10 1/2" 15' - 11" 5' - 0"
12' - 4 1/2" 5' - 4 1/2" 5' - 4 1/2"
7' -
7"
4' - 0"
65' - 9" 13' - 6" 4' - 8"
7' - 5" 5' - 2 1/2" 4' - 7" 3' - 0" 8' - 9 1/2" 7' - 10"
76
53
28
29
85
84
65
83' - 11"
51
' -
1 1
/2"
1' -
7"
5' -
1 1
/2"
5' -
1 1
/2"
8' -
9"
4' -
11
1/2
"6
' -
9"
11
' -
2"
7' -
8 1
/2"
20
' -
7"
22
' - 1
0 1
/2"
51
' -
1 1
/2"
19' - 0"
8' - 9" 10' - 3"
83' - 11"
DR
AW
ING
S A
ND
SP
EC
IFIC
ATI
ON
S R
EM
AIN
TH
E P
RO
PE
RTY
OF
THE
DE
SIG
N P
RO
FES
SIO
NA
L. C
OP
IES
OF
THE
DR
AW
ING
S A
ND
SP
EC
IFIC
ATI
ON
S R
ETA
INE
D B
Y T
HE
CLI
EN
T M
AY
BE
UTI
LIZE
D O
NLY
FO
R H
IS U
SE
AN
D F
OR
OC
CU
PY
ING
TH
E P
RO
JEC
T FO
R W
HIC
H T
HE
Y W
ER
E P
RE
PA
RE
D, A
ND
NO
T FO
R T
HE
CO
NS
TRU
CTI
ON
OF
AN
Y O
THE
R P
RO
JEC
T.
SHEET NUMBER
RE
VIS
ION
S
DR
AW
ING
TIT
LE
:
SE
AL
NEVADA STATE BOARD OF ARCHITECTURELICENSE # 90-P
DENNIS BEDFORDRESIDENTIAL DESIGNER320 E. WARM SPRINGS, SUITE # 2ALAS VEGAS, NV 89119TEL: (702) 497-8686
DATE:
DESIGN BY:
DRAWN BY:
CHECKED BY:
D. B.
D.B.
D. B.
DA
TE
Keyno
tes
Ge
ne
ral N
ote
s
3/19/2020 9:32:29 AM
A-2.2
E-S
YN
ER
GY
RE
SID
EN
CE
404
9 H
AT
CH
ST
., N
. LA
SV
EG
AS
, N
V.
89
03
2
UP
PE
R L
EV
EL -
FLO
OR
PL
AN
FLOOR PLAN - KEYNOTES
1.0 WATER CLOSET W/ 30" WIDE X 24" DEEP CLEAR SPACE CENTEREDON FRONT OF FIXTURE (I.R.C. R307) COMPLY W/UPC
1.1 LAVATORY - VERIFY DIM. W/ MFR. SPEC.
1.3 TUB/SHOWER COMBINATION W/ WAINSCOT TO 72" MIN. ABOVEDRAIN OVER DENSHIELD OR EQUAL FIBER CEMENT BACKERBOARD. VERIFY DIM. W/ MFR. SPEC.
1.4 SHOWER W/ WAINSCOT TO CLG. ABOVE DRAIN OVER DENSHIELDOR EQUAL FIBER CEMENT BACKER BOARD. VERIFY DIMS. W/ MFR.SPEC. TEMPERED GLAZING @ ENCLOSURE.
1.5 FREESTANDING TUB - VERIFY DIM. W/ MFR. SPEC. INSTALL PERMFR SPEC. PROVIDE CEILING FILLER.
2.0 KITCHEN SINK W/ GARBAGE DISPOSAL - VERIFY DIM. W/ MFR SPEC./R.O. WATER
2.1 DISHWASHER - PROVIDE SURFACE MOUNT AIR GAP - VERIFY DIM.W/ MFR. SPEC.
2.3 36" H. BASE CAB. W/ UPPER CABINETS PER PLAN.
4.0 WASHER SPACE: PROVIDE WATER CONTROL VALVES AND WASTERECESSED IN WALL. TOP OF BOX AT +42" A.F.F.
4.1 DRYER SPACE: PROVIDED SMOOTH METAL DRYER VENT DUCT TOOUTSIDE WITH BACKDRAFT DAMPER 4" DIA. AND 14' MAX. LENGTHWITH 2 ELBOWS MAX. (U.M.C. 504.3.2.1)
4.4 PANTRY SHELVES.
4.5 (5) SHELVES.
4.8 GAS FIRE PLACE APPLIANC, WOODLAND DIRECT: SUPERIO RDRC2000 DIRECT VENT UL LISTED AND 1721.88.
5.7 ROD & SHELF
13.1 5/8" TYPE 'X' GYP BD @ WALLS & CLG R302.5.1, R302.6.
16.4 42" H. RAILING: GUARDRAIL OPENING LIMITATIONS. REQ. GUARDSON OPEN SIDES OF STAIRWAYS, RAISED FLOOR AREAS, BALCONESAND PORCHES SHALL HAVE INTERMEDIATE RAILS ORORNAMENTAL CLOSURES WICH DO NOT ALLOW PASSAGE OF ASPHERE 4" OR MORE IN DIAMETER.
3/16" = 1'-0"1UPPER LEVEL
ATTIC VENTILATION CALCULATION
ATTIC SPACES ABOVE LIVABLE AREAS SHALL BE CONDITIONED PER I.R.C. R806.4.
ATTIC VENTILATION: THE TOTAL NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1 TO 150 OF THE AREA OF THE SPACE VENTILATED EXCEPT THAT THE TOTAL AREA IS PERMITTED TO BE REDUCED TO 1 TO 300, PROVIDED AT LEAST 50 PERCENT AND NOT MORE THAN 80 PERCENT OF THE REQUIRED VENTILATING AREA IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE SPACE TO BE VENTILATED AT LEAST 3 FEET ABOVE EAVE OR CORNICE VENTS.
AREA 1 ELEVATION - A & B
VENTILATION REQUIRED: 1,560 x SQ. FT. / 300 = 5.2 SQ. FT.X 144 SQ. IN. = 749 SQ. IN.
VENTILATION PROVIDED:
HIGH VENTILATION REQUIRED = 375 SQ.IN(4)O'HAGEN VENTS @ 97.5 SQ.IN EA. = 390 SQ.INTOTAL HIGH VENTILATION PROVIDED 390 SQ.IN
LOW VENTILATION REQUIRED = 375 SQ.INLOW VENTILATION PROVIDED: (4) X OHAGEN VENTS @(97.5) SQ. IN. = 390 SQ.IN
TOTAL VENTILATION PROVIDED - (NET FREE) = 780 SQ.IN
1. NOT ALL KEYNOTES MAY APPLY.
2. PROVIDE 24 GA. G.I. "PAINT LOCK FLASHING AT ALL BREAKS IN ROOF COVERING
3. PROVIDE DRAFTS STOPS PER IRC.
4. LOCATION OF FAU IN THE ATTIC TO BE IN SUCH A MANNER THAT THE REQUIRED DISTANCE FROM THE VENT OUTLET TO THE TOP OF THE FLUE CAP IS WITH THE ATTIC ALLOWING THE EXTERIOR HEIGHT OF THE FLUE CAP ABOVE THE FINISHED ROOFING TO BE THE MINIMUM ALLOWED BY CODE.
5. ALL PLUMBING AND EQUIPMENT VENTS MUST BE CONSOLIDATED AND LOCATED IN AREAS THAT MINIMIZE THEIR VISIBILITY AND SHALL NOT BE LOCATED IN SLOPED ROOF AREAS. THESE SHALL BE LOCATED IN THE FLAT PORTIONS OF THE ROOF. VENTS MUST BE AS LOW IN HEIGHT AS ALLOWED BY CODE.
6. SEE DETAIL SHEET AD-1.0 FOR TYPICAL DETAILS.
7. NO ROOF PENETRATIONS TO OCCUR WITH IN 1'-6" OF VALLEY, HIPS OR RIDGES. (I.E. ATTIC VENTS, CHIMNEYS, PLUMBING OR DRYER VENTS, ETC.)
8. UNVENTED ATTIC ASSEMBLIES LOCATED WITHIN THE BUILDING THERMAL ENVELOPE SHALL BE CONDITIONED PER I.R.C. R806.4
- NO INTERIOR VAPOR RETARDERS ARE TO BE INSTALLED ON THE CEILING SIDE OF UNVENTED ATTIC SPACE.- AIR-IMPERMEABLE INSULATION ONLY, INSULATION SHALL BE APPLIED IN DIRECT CONTACT WITH THE UNDERSIDE OF THE STRUCTURAL ROOF SHEATHING.
8"
/ F
T
8"
/ F
T
8"
/ F
T
3"
/ F
T
4" / FT4" / FT
6"
/ F
T6"
/ F
T
6"
/ F
T
6"
/ F
T
6"
/ F
T
6"
/ F
T
DR
AW
ING
S A
ND
SP
EC
IFIC
ATI
ON
S R
EM
AIN
TH
E P
RO
PE
RTY
OF
THE
DE
SIG
N P
RO
FES
SIO
NA
L. C
OP
IES
OF
THE
DR
AW
ING
S A
ND
SP
EC
IFIC
ATI
ON
S R
ETA
INE
D B
Y T
HE
CLI
EN
T M
AY
BE
UTI
LIZE
D O
NLY
FO
R H
IS U
SE
AN
D F
OR
OC
CU
PY
ING
TH
E P
RO
JEC
T FO
R W
HIC
H T
HE
Y W
ER
E P
RE
PA
RE
D, A
ND
NO
T FO
R T
HE
CO
NS
TRU
CTI
ON
OF
AN
Y O
THE
R P
RO
JEC
T.
SHEET NUMBER
RE
VIS
ION
S
DR
AW
ING
TIT
LE
:
SE
AL
NEVADA STATE BOARD OF ARCHITECTURELICENSE # 90-P
DENNIS BEDFORDRESIDENTIAL DESIGNER320 E. WARM SPRINGS, SUITE # 2ALAS VEGAS, NV 89119TEL: (702) 497-8686
DATE:
DESIGN BY:
DRAWN BY:
CHECKED BY:
D. B.
D.B.
D. B.
DA
TE
Keyno
tes
Ge
ne
ral N
ote
s
3/19/2020 9:32:35 AM
A-3.0
E-S
YN
ER
GY
RE
SID
EN
CE
404
9 H
AT
CH
ST
., N
. LA
SV
EG
AS
, N
V.
89
03
2
RO
OF
PL
AN
3/16" = 1'-0"1ROOF PLAN
LOWER LEVEL0' - 0"
T.O. PLATE 210' - 1"
UPPER LEVEL12' - 2 1/8"
T.O. PLATE 322' - 3 1/8"
T.O. PLATEGARAGE
14' - 11 7/8"
H. H. WINDOWSUPPER LEVEL
18' - 10 1/8"
H. H. WINDOWSLOWER LEVEL
8' - 0"
T.O. PLATE 820' - 3 1/8"
LOWER LEVEL0' - 0"
T.O. PLATE 210' - 1"
UPPER LEVEL12' - 2 1/8"
T.O. PLATE 322' - 3 1/8"
T.O. PLATEGARAGE
14' - 11 7/8"
LOWER LEVEL0' - 0"
T.O. PLATE 210' - 1"
T.O. PLATE 1-2' - 1 1/8"
BASEMENT-11' - 2 1/8"
UPPER LEVEL12' - 2 1/8"
T.O. PLATE 322' - 3 1/8"
T.O. PLATEGARAGE
14' - 11 7/8"
H. H. WINDOWSUPPER LEVEL
18' - 10 1/8"
H. H. WINDOWSUPPER LEVEL
18' - 10 1/8"
H. H. WINDOWSLOWER LEVEL
8' - 0"H. H. WINDOWS
LOWER LEVEL8' - 0"
T.O. PLATE 820' - 3 1/8"
H. H. WINDOWSBASEMENT
-3' - 2 1/8"
DR
AW
ING
S A
ND
SP
EC
IFIC
ATI
ON
S R
EM
AIN
TH
E P
RO
PE
RTY
OF
THE
DE
SIG
N P
RO
FES
SIO
NA
L. C
OP
IES
OF
THE
DR
AW
ING
S A
ND
SP
EC
IFIC
ATI
ON
S R
ETA
INE
D B
Y T
HE
CLI
EN
T M
AY
BE
UTI
LIZE
D O
NLY
FO
R H
IS U
SE
AN
D F
OR
OC
CU
PY
ING
TH
E P
RO
JEC
T FO
R W
HIC
H T
HE
Y W
ER
E P
RE
PA
RE
D, A
ND
NO
T FO
R T
HE
CO
NS
TRU
CTI
ON
OF
AN
Y O
THE
R P
RO
JEC
T.
SHEET NUMBER
RE
VIS
ION
S
DR
AW
ING
TIT
LE
:
SE
AL
NEVADA STATE BOARD OF ARCHITECTURELICENSE # 90-P
DENNIS BEDFORDRESIDENTIAL DESIGNER320 E. WARM SPRINGS, SUITE # 2ALAS VEGAS, NV 89119TEL: (702) 497-8686
DATE:
DESIGN BY:
DRAWN BY:
CHECKED BY:
D. B.
D.B.
D. B.
DA
TE
Keyno
tes
Ge
ne
ral N
ote
s
3/19/2020 9:34:58 AM
A-4.0
E-S
YN
ER
GY
RE
SID
EN
CE
404
9 H
AT
CH
ST
., N
. LA
SV
EG
AS
, N
V.
89
03
2
EX
TE
RIO
R E
LE
VA
TIO
N
3/16" = 1'-0"1FRONT ELEVATION
3/16" = 1'-0"2RIGHT ELEVATION
3/16" = 1'-0"3REAR ELEVATION
LOWER LEVEL0' - 0"
T.O. PLATE 210' - 1"
T.O. PLATE 1-2' - 1 1/8"
BASEMENT-11' - 2 1/8"
UPPER LEVEL12' - 2 1/8"
T.O. PLATE 322' - 3 1/8"
H. H. WINDOWSUPPER LEVEL
18' - 10 1/8"
H. H. WINDOWSLOWER LEVEL
8' - 0"
T.O. PLATE 820' - 3 1/8"
H. H. WINDOWSBASEMENT
-3' - 2 1/8"
DR
AW
ING
S A
ND
SP
EC
IFIC
ATI
ON
S R
EM
AIN
TH
E P
RO
PE
RTY
OF
THE
DE
SIG
N P
RO
FES
SIO
NA
L. C
OP
IES
OF
THE
DR
AW
ING
S A
ND
SP
EC
IFIC
ATI
ON
S R
ETA
INE
D B
Y T
HE
CLI
EN
T M
AY
BE
UTI
LIZE
D O
NLY
FO
R H
IS U
SE
AN
D F
OR
OC
CU
PY
ING
TH
E P
RO
JEC
T FO
R W
HIC
H T
HE
Y W
ER
E P
RE
PA
RE
D, A
ND
NO
T FO
R T
HE
CO
NS
TRU
CTI
ON
OF
AN
Y O
THE
R P
RO
JEC
T.
SHEET NUMBER
RE
VIS
ION
S
DR
AW
ING
TIT
LE
:
SE
AL
NEVADA STATE BOARD OF ARCHITECTURELICENSE # 90-P
DENNIS BEDFORDRESIDENTIAL DESIGNER320 E. WARM SPRINGS, SUITE # 2ALAS VEGAS, NV 89119TEL: (702) 497-8686
DATE:
DESIGN BY:
DRAWN BY:
CHECKED BY:
D. B.
D.B.
D. B.
DA
TE
Keyno
tes
Ge
ne
ral N
ote
s
3/19/2020 9:37:01 AM
A-4.1
E-S
YN
ER
GY
RE
SID
EN
CE
404
9 H
AT
CH
ST
., N
. LA
SV
EG
AS
, N
V.
89
03
2
EX
TE
RIO
R E
LE
VA
TIO
N
3/16" = 1'-0"1LEFT ELEVATION