DRAWING LIST - Anacond Contracting Inc.

30
LEGEND DRAWING LIST DATE INITIAL REVISIONS No. DESIGN DATE: DRAWN CHECKED DRAWING NUMBER SIGNED SCALE: CONTRACT No. 2019-11-01 ISSUED FOR 60% CONSTRUCTION DOCUMENTS 1 WS2492514132 CITY ASSET No. 297 DUFFERIN GROVE PARK NORTH-WEST CORNER AND CLUBHOUSE IMPROVEMENTS DRAWING PRINT DATE: 7/10/2020 5:03:01 PM FILENAME: \\TAF_SERVER\taf_main\Projects\Current Projects\18173 DUFFERIN GROVE PARK IMPROVEMENTS\300 Design\301 ME Dwgs\18173 MECH\18173 m metric.dwg YA YA BZ JOB NUMBER: 18173 2020-01-17 ISSUED FOR 90% COORDINATION 2 2020-02-14 PROGRESS SET 3 2020-03-06 ISSUED FOR PERMIT 4 2020-03-06 2020-03-24 ISSUED FOR CD'S 5 2020-06-12 2020-06-12 ISSUED FOR TENDER 6

Transcript of DRAWING LIST - Anacond Contracting Inc.

LEGENDDRAWING LIST

DATE INITIALREVISIONSNo.

DESIGN

DATE:

DRAWNCHECKED

DRAWING NUMBER

SIGNED

SCALE: CONTRACT No.

2019-11-01 ISSUED FOR 60% CONSTRUCTION DOCUMENTS1

WS2492514132

CITY ASSET No. 297

DUFFERIN GROVE PARK NORTH-WEST CORNER

AND CLUBHOUSE IMPROVEMENTS

DR

AW

IN

G P

RIN

T D

AT

E: 7/10/2020 5:03:01 P

M

FIL

EN

AM

E: \\T

AF

_S

ER

VE

R\taf_m

ain

\P

ro

jects\C

urren

t P

ro

jects\18173 D

UF

FE

RIN

G

RO

VE

P

AR

K IM

PR

OV

EM

EN

TS

\300 D

esig

n\301 M

E D

wg

s\18173 M

EC

H\18173

m m

etric.d

wg

YA YA BZ

JOB NUMBER: 18173

2020-01-17 ISSUED FOR 90% COORDINATION2

2020-02-14 PROGRESS SET3

2020-03-06 ISSUED FOR PERMIT4

2020-03-06

2020-03-24 ISSUED FOR CD'S5

2020-06-12

2020-06-12 ISSUED FOR TENDER6

AutoCAD SHX Text
RETURN AIR GRILLE
AutoCAD SHX Text
WATER CLOSET
AutoCAD SHX Text
WC
AutoCAD SHX Text
LAVATORY
AutoCAD SHX Text
L
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
WALL/FLOOR CLEAN OUT
AutoCAD SHX Text
PIPE RISER
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
DN
AutoCAD SHX Text
CTE
AutoCAD SHX Text
CONNECT TO EXISTING
AutoCAD SHX Text
THERMOSTAT
AutoCAD SHX Text
T
AutoCAD SHX Text
RETURN/EXHAUST AIR DUCT RISER
AutoCAD SHX Text
SUPPLY/FRESH AIR DUCT RISER
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
SPIN-ON FITTING WITH BALANCING DAMPER
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
A
AutoCAD SHX Text
C-TYPE OF DIFFUSER/GRILLE/REGISTER
AutoCAD SHX Text
B-AIR QUANTITY (L/S)
AutoCAD SHX Text
A-SIZE OF DIFFUSER/GRILLE/REGISTER
AutoCAD SHX Text
PENDANT/SEMI-RECESSED TYPE SPRINKLER HEAD
AutoCAD SHX Text
CONCEALED RECESSED TYPE SPRINKLER HEAD
AutoCAD SHX Text
UPRIGHT TYPE SPRINKLER HEAD
AutoCAD SHX Text
SUPPLY AIR DUCT
AutoCAD SHX Text
SAD
AutoCAD SHX Text
RETURN AIR DUCT
AutoCAD SHX Text
RAD
AutoCAD SHX Text
EXHAUST AIR DUCT
AutoCAD SHX Text
EAD
AutoCAD SHX Text
BD
AutoCAD SHX Text
VOLUME DAMPER
AutoCAD SHX Text
BALANCING DAMPER
AutoCAD SHX Text
VD
AutoCAD SHX Text
RETURN AIR
AutoCAD SHX Text
R/A
AutoCAD SHX Text
PLAQUE TYPE SUPPLY AIR DIFFUSER
AutoCAD SHX Text
TRANSFER AIR DUCT
AutoCAD SHX Text
TAD
AutoCAD SHX Text
ACOUSTICALLY LINED DUCTWORK
AutoCAD SHX Text
BD
AutoCAD SHX Text
REMOVE EXISTING RIGID DUCTWORK
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
SAN
AutoCAD SHX Text
STM
AutoCAD SHX Text
SAN
AutoCAD SHX Text
STM
AutoCAD SHX Text
EXISTING SUPPLY AIR DUCT
AutoCAD SHX Text
EXISTING SANITARY LINE (BELOW GRADE)
AutoCAD SHX Text
EXISTING STORM LINE (BELOW GRADE)
AutoCAD SHX Text
NEW SANITARY LINE (BELOW GRADE)
AutoCAD SHX Text
NEW STORM LINE (ABOVE GRADE)
AutoCAD SHX Text
SAN
AutoCAD SHX Text
NEW SANITARY LINE (ABOVE GRADE)
AutoCAD SHX Text
V
AutoCAD SHX Text
VENT LINE
AutoCAD SHX Text
F.E.
AutoCAD SHX Text
FIRE EXTINGUISHER
AutoCAD SHX Text
NEW SUPPLY AIR DUCT
AutoCAD SHX Text
EXISTING SPRINKLER HEAD
AutoCAD SHX Text
RELOCATE
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
FLOOR DRAIN
AutoCAD SHX Text
FD
AutoCAD SHX Text
EXISTING/NEW DOMESTIC HOT WATER PIPE
AutoCAD SHX Text
EXISTING/NEW DOMESTIC COLD WATER PIPE
AutoCAD SHX Text
DOOR UNDERCUT (SIZE AS NOTED)
AutoCAD SHX Text
U/C
AutoCAD SHX Text
SENSOR FOR THERMOSTAT
AutoCAD SHX Text
S
AutoCAD SHX Text
E
AutoCAD SHX Text
SP
AutoCAD SHX Text
EXISTING SPRINKLER LINE
AutoCAD SHX Text
E
AutoCAD SHX Text
FUNNEL DRAIN
AutoCAD SHX Text
FFD
AutoCAD SHX Text
WATER FOUNTAIN
AutoCAD SHX Text
WF
AutoCAD SHX Text
ROOF DRAIN
AutoCAD SHX Text
RD
AutoCAD SHX Text
EYE WASH STATION
AutoCAD SHX Text
EW
AutoCAD SHX Text
HOSE BIB
AutoCAD SHX Text
HB
AutoCAD SHX Text
NON-FREEZE HOSE BIB
AutoCAD SHX Text
NFHB
AutoCAD SHX Text
BOTTLE FILLER
AutoCAD SHX Text
BF
AutoCAD SHX Text
MECHANICAL HVAC PLANS
AutoCAD SHX Text
KITCHEN ROOF PLAN
AutoCAD SHX Text
PLUMBING PLAN-1
AutoCAD SHX Text
CALCULATION
AutoCAD SHX Text
MECHANICAL DETAILS-1
AutoCAD SHX Text
MECHANICAL DETAILS-2
AutoCAD SHX Text
MECHANICAL DETAIL-3
AutoCAD SHX Text
DRAINAGE PLAN-1
AutoCAD SHX Text
MECHANICAL SCHEDULE-1
AutoCAD SHX Text
M1
AutoCAD SHX Text
M2
AutoCAD SHX Text
M3
AutoCAD SHX Text
M4.1
AutoCAD SHX Text
M4.2
AutoCAD SHX Text
M4.3
AutoCAD SHX Text
M5.1
AutoCAD SHX Text
M5.2
AutoCAD SHX Text
M5.3
AutoCAD SHX Text
M6
AutoCAD SHX Text
M7
AutoCAD SHX Text
M8.1
AutoCAD SHX Text
M8.2
AutoCAD SHX Text
M8.3
AutoCAD SHX Text
MECHANICAL LEGEND & DRAWING LIST
AutoCAD SHX Text
PLUMBING PLAN-2
AutoCAD SHX Text
PLUMBING PLAN-3
AutoCAD SHX Text
DRAINAGE PLAN-2
AutoCAD SHX Text
DRAINAGE PLAN-3
AutoCAD SHX Text
MECHANICAL SCHEDULE-2
AutoCAD SHX Text
M6.1
AutoCAD SHX Text
LEGEND AND DRAWING LIST
AutoCAD SHX Text
M1
AutoCAD SHX Text
PH.: (905) 946 4260 FAX: (905) 946 0901
AutoCAD SHX Text
MARKHAM ONTARIO L3R 1A3
AutoCAD SHX Text
UNIT 229
AutoCAD SHX Text
7181 WOODBINE AVE
AutoCAD SHX Text
%%UTHOMAS A. FEKETE LIMITED

REFLECTED CEILING PLAN1

HVAC CODED NOTES:

B C D

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

AE

2

C A

4

3

DB

1

DATE INITIALREVISIONSNo.

DESIGN

DATE:

DRAWNCHECKED

DRAWING NUMBER

SIGNED

SCALE: CONTRACT No.

2019-11-01 ISSUED FOR 60% CONSTRUCTION DOCUMENTS1

WS2492514132

CITY ASSET No. 297

DUFFERIN GROVE PARK NORTH-WEST CORNER

AND CLUBHOUSE IMPROVEMENTS

DR

AW

IN

G P

RIN

T D

AT

E: 7/10/2020 5:03:08 P

M

FIL

EN

AM

E: \\T

AF

_S

ER

VE

R\taf_m

ain

\P

ro

jects\C

urren

t P

ro

jects\18173 D

UF

FE

RIN

G

RO

VE

P

AR

K IM

PR

OV

EM

EN

TS

\300 D

esig

n\301 M

E D

wg

s\18173 M

EC

H\18173

m m

etric.d

wg

YA YA BZ

JOB NUMBER: 18173

2020-01-17 ISSUED FOR 90% COORDINATION2

2020-02-14 PROGRESS SET3

2020-03-06 ISSUED FOR PERMIT4

2020-03-06

2020-03-24 ISSUED FOR CD'S5

2020-06-12

2020-06-12 ISSUED FOR TENDER6

AutoCAD SHX Text
EF-1
AutoCAD SHX Text
350X300
AutoCAD SHX Text
BD
AutoCAD SHX Text
300%%C
AutoCAD SHX Text
300%%C
AutoCAD SHX Text
BD
AutoCAD SHX Text
BD
AutoCAD SHX Text
250%%C
AutoCAD SHX Text
250%%C
AutoCAD SHX Text
FRESH AIR INTAKE
AutoCAD SHX Text
200%%C
AutoCAD SHX Text
BD
AutoCAD SHX Text
500X400
AutoCAD SHX Text
BD
AutoCAD SHX Text
EF-5
AutoCAD SHX Text
400X250
AutoCAD SHX Text
500X500
AutoCAD SHX Text
BD
AutoCAD SHX Text
BD
AutoCAD SHX Text
350%%C
AutoCAD SHX Text
RTU-1 7.5 TON
AutoCAD SHX Text
171
AutoCAD SHX Text
A
AutoCAD SHX Text
300%%C
AutoCAD SHX Text
TYPICAL OF 4
AutoCAD SHX Text
212
AutoCAD SHX Text
A
AutoCAD SHX Text
300%%C
AutoCAD SHX Text
TYPICAL OF 2
AutoCAD SHX Text
BD
AutoCAD SHX Text
250%%C
AutoCAD SHX Text
118
AutoCAD SHX Text
B
AutoCAD SHX Text
600X600
AutoCAD SHX Text
71
AutoCAD SHX Text
B
AutoCAD SHX Text
600X600
AutoCAD SHX Text
350X350
AutoCAD SHX Text
250%%C
AutoCAD SHX Text
250%%C
AutoCAD SHX Text
47
AutoCAD SHX Text
H
AutoCAD SHX Text
250X150
AutoCAD SHX Text
350X250
AutoCAD SHX Text
BD
AutoCAD SHX Text
BD
AutoCAD SHX Text
250%%C
AutoCAD SHX Text
250%%C
AutoCAD SHX Text
189
AutoCAD SHX Text
B
AutoCAD SHX Text
600X600
AutoCAD SHX Text
TYPICAL OF 2
AutoCAD SHX Text
71
AutoCAD SHX Text
H
AutoCAD SHX Text
250X150
AutoCAD SHX Text
SCALE : 1:100
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
EF-3
AutoCAD SHX Text
BD
AutoCAD SHX Text
BD
AutoCAD SHX Text
BD
AutoCAD SHX Text
BD
AutoCAD SHX Text
BD
AutoCAD SHX Text
EF-4
AutoCAD SHX Text
UP THROUGH ROOF
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
4
AutoCAD SHX Text
3
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
SUPPLY AND INSTALL CO-CENTRIC VENTILATION KIT FOR THE GAS FIRE PLACE. PIPE SHALL TERMINATE AT ROOF.
AutoCAD SHX Text
#
AutoCAD SHX Text
11
AutoCAD SHX Text
1
AutoCAD SHX Text
BD
AutoCAD SHX Text
250X300
AutoCAD SHX Text
BD
AutoCAD SHX Text
350X350
AutoCAD SHX Text
236
AutoCAD SHX Text
F
AutoCAD SHX Text
450X300
AutoCAD SHX Text
TYPICAL OF 3
AutoCAD SHX Text
378
AutoCAD SHX Text
F
AutoCAD SHX Text
300X600
AutoCAD SHX Text
450X400
AutoCAD SHX Text
550X500
AutoCAD SHX Text
400X350
AutoCAD SHX Text
300X300
AutoCAD SHX Text
CREATE A VERTICAL DUCT DROP AND TERMINATES AT 300MM AFF. SUPPLY AND INSTALL RETURN/EXHAUST GRILLE ON THE SIDE OF THE VERTICAL DROP AT LOW LEVEL.
AutoCAD SHX Text
2
AutoCAD SHX Text
542
AutoCAD SHX Text
G
AutoCAD SHX Text
1200X1200
AutoCAD SHX Text
TYPICAL OF 2
AutoCAD SHX Text
MD-1&2
AutoCAD SHX Text
MD-3
AutoCAD SHX Text
SUPPLY AND INSTALL FRESH AIR LOUVERS. COMPLETE WITH BIRD SCREEN AND MOTORIZED DAMPERS. INTERLOCK DAMPER WITH EXHAUST FAN-3. REFER TO 'REFRIGERATION ROOM (002) SEQUENCE OF OPERATION' AND DETAIL FOR INSTALLATION AND CONTROL. MOTORIZED DAMPER ACTUATORS SHALL BE BELIMO FIRE&SMOKE SERIES. LOW VOLTAGE DONE BY MECHANICAL CONTRACTOR.
AutoCAD SHX Text
CF-1
AutoCAD SHX Text
CF-2
AutoCAD SHX Text
CF-3
AutoCAD SHX Text
CF-4
AutoCAD SHX Text
CF-5
AutoCAD SHX Text
CF-6
AutoCAD SHX Text
CF-7
AutoCAD SHX Text
CF-8
AutoCAD SHX Text
BD
AutoCAD SHX Text
3
AutoCAD SHX Text
UH-2
AutoCAD SHX Text
UH-1
AutoCAD SHX Text
T
AutoCAD SHX Text
350X300
AutoCAD SHX Text
350X350
AutoCAD SHX Text
UP TO ROOF DECK
AutoCAD SHX Text
VEST
AutoCAD SHX Text
001
AutoCAD SHX Text
MECH
AutoCAD SHX Text
003
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
004
AutoCAD SHX Text
STAFF
AutoCAD SHX Text
018
AutoCAD SHX Text
POS
AutoCAD SHX Text
016
AutoCAD SHX Text
CRP OFFICE
AutoCAD SHX Text
015
AutoCAD SHX Text
JC
AutoCAD SHX Text
012
AutoCAD SHX Text
COMMS
AutoCAD SHX Text
011
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
020
AutoCAD SHX Text
CIRCULATION
AutoCAD SHX Text
005
AutoCAD SHX Text
REFRIGERATION
AutoCAD SHX Text
002
AutoCAD SHX Text
U-WC
AutoCAD SHX Text
010
AutoCAD SHX Text
WC
AutoCAD SHX Text
009
AutoCAD SHX Text
WC
AutoCAD SHX Text
008
AutoCAD SHX Text
WC
AutoCAD SHX Text
007
AutoCAD SHX Text
WC
AutoCAD SHX Text
006
AutoCAD SHX Text
MULTI-PURPOSE
AutoCAD SHX Text
014
AutoCAD SHX Text
MULTI-PURPOSE
AutoCAD SHX Text
013
AutoCAD SHX Text
SKATES
AutoCAD SHX Text
017
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
019
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
100 DRYER VENT
AutoCAD SHX Text
SKATE SHARPENER EXHAUST (150 )
AutoCAD SHX Text
100 DRYER VENTUP THROUGH ROOF
AutoCAD SHX Text
COORDINATE ALL DUCT WORK WITH STRUCTURAL MEMBERS. CONFIRM EXACT ROUTE OF DUCT WORK ON SITE.
AutoCAD SHX Text
4
AutoCAD SHX Text
4
AutoCAD SHX Text
4
AutoCAD SHX Text
4
AutoCAD SHX Text
SUPPLY AND INSTALL UNIT HEATER AS INDICATED ON THE DRAWING. REFER TO SCHEDULE FOR MODEL NUMBER.
AutoCAD SHX Text
5
AutoCAD SHX Text
EF-2
AutoCAD SHX Text
SUPPLY AND INSTALL TRANSFER AIR GRILLES FOR ELECTRICAL/MECHANICAL ROOM AS INDICATED ON THE DRAWING.
AutoCAD SHX Text
6
AutoCAD SHX Text
SUPPLY AND INSTALL EXHAUST FAN WITHIN THE MECHANICAL/ELECTRICAL ROOM FOR AIR CIRCULATION.
AutoCAD SHX Text
7
AutoCAD SHX Text
SUPPLY AND INSTALL EXHAUST FAN FOR WASHROOMS AND JANITOR ROOM. EACH GRILLE SHALL BE BALANCED AS PER THE DRAWING. PUT UNDER CUT ON DOORS.
AutoCAD SHX Text
8
AutoCAD SHX Text
35
AutoCAD SHX Text
F
AutoCAD SHX Text
300X300
AutoCAD SHX Text
TYPICAL OF 6
AutoCAD SHX Text
SUPPLY AND INSTALL CEILING FAN AS INDICATED ON THE DRAWING.
AutoCAD SHX Text
9
AutoCAD SHX Text
INSTALL DRYER VENT PIPING UP THROUGH ROOF AS INDICATED. MAKE SURE VENT TERMINAL AT THE ROOF HAS ENOUGH CLEARANCE FROM ANY FRESH AIR INTAKES ACCORDING TO APPLICABLE CODES.
AutoCAD SHX Text
10
AutoCAD SHX Text
INSTALL SKATE GRINDER VENT PIPING UP THROUGH ROOF AS INDICATED. MAKE SURE VENT TERMINAL AT THE ROOF HAS ENOUGH CLEARANCE FROM ANY FRESH AIR INTAKES ACCORDING TO APPLICABLE CODES.
AutoCAD SHX Text
11
AutoCAD SHX Text
FD
AutoCAD SHX Text
-
AutoCAD SHX Text
G
AutoCAD SHX Text
450X300
AutoCAD SHX Text
HWT-1
AutoCAD SHX Text
CONNECT 150 INTAKE AND EXHAUST DUCT FOR THE HOT WATER TANK-1.TERMINATES AT THE CONCENTRIC VENT KIT ABOVE ROOF. OFFSET SO THAT THE KIT HAS ENOUGH CLEARANCE FROM FRESH AIR INTAKES.
AutoCAD SHX Text
12
AutoCAD SHX Text
12
AutoCAD SHX Text
CONNECT 150 INTAKE AND EXHAUST DUCT FOR THE HOT WATER TANK-2.TERMINATES AT THE CONCENTRIC VENT KIT ON THE SIDE WALL AS HIGH AS POSSIBLE.
AutoCAD SHX Text
13
AutoCAD SHX Text
13
AutoCAD SHX Text
HWT-2
AutoCAD SHX Text
-
AutoCAD SHX Text
I
AutoCAD SHX Text
500X400
AutoCAD SHX Text
T
AutoCAD SHX Text
FFH-1
AutoCAD SHX Text
2KW
AutoCAD SHX Text
SUPPLY AND INSTALL NEW FORCE FLOW HEATER ACCORDING TO THE DRAWING. COMPLETE WITH BUILT IN SENSOR.
AutoCAD SHX Text
14
AutoCAD SHX Text
14
AutoCAD SHX Text
300%%C
AutoCAD SHX Text
150%%C
AutoCAD SHX Text
150%%C
AutoCAD SHX Text
150%%C
AutoCAD SHX Text
150%%C
AutoCAD SHX Text
150%%C
AutoCAD SHX Text
150%%C
AutoCAD SHX Text
250%%C
AutoCAD SHX Text
300%%C GOOSENECK INTAKE
AutoCAD SHX Text
SUPPLY AND INSTALL GOOSENECK FOR AIR CIRCULATION. COMPLETE WITH MOTORIZED DAMPER AND INTERLOCK ACTUATOR WITH EF-2. MD-4 SHALL BE BELIMO FAIL SAFE SERIES.
AutoCAD SHX Text
15
AutoCAD SHX Text
15
AutoCAD SHX Text
M
AutoCAD SHX Text
MD-4
AutoCAD SHX Text
MD-5
AutoCAD SHX Text
M
AutoCAD SHX Text
CONCENTRIC VENT
AutoCAD SHX Text
CONCENTRIC VENT
AutoCAD SHX Text
350X300
AutoCAD SHX Text
T
AutoCAD SHX Text
SUPPLY AND INSTALL FRESH AIR INTAKE LOUVER, COMPLETE WITH MOTORIZED DAMPER (MD-5). ACTUATOR SHALL BE BELIMO FAIL-SAFE ACTUATOR. ACTUATOR INTERLOCKED WITH EF-5.
AutoCAD SHX Text
16
AutoCAD SHX Text
16
AutoCAD SHX Text
T
AutoCAD SHX Text
T
AutoCAD SHX Text
UH-4
AutoCAD SHX Text
2KW
AutoCAD SHX Text
5
AutoCAD SHX Text
HOOD CONTROL PANEL
AutoCAD SHX Text
REMOTE FUELING PANEL
AutoCAD SHX Text
REMOTE FUELING PANEL SHALL BE INTERLOCKED WITH THE MECHANICAL EXHAUST FAN. PROVIDED CEILING MOUNTED METHANE DETECTOR.
AutoCAD SHX Text
17
AutoCAD SHX Text
17
AutoCAD SHX Text
D
AutoCAD SHX Text
ROOF DECK HEIGHT CHANGE
AutoCAD SHX Text
-
AutoCAD SHX Text
J
AutoCAD SHX Text
300X300
AutoCAD SHX Text
SUPPLY AND INSTALL FIRE RATED DOOR GRILLE FOR JANITOR ROOM. SIZE IS INDICATED ON THE DRAWING.
AutoCAD SHX Text
18
AutoCAD SHX Text
18
AutoCAD SHX Text
UH-3
AutoCAD SHX Text
2KW
AutoCAD SHX Text
5
AutoCAD SHX Text
REFRIGERANT ROOM CONTROL PANEL
AutoCAD SHX Text
T
AutoCAD SHX Text
378
AutoCAD SHX Text
F
AutoCAD SHX Text
350X300
AutoCAD SHX Text
S
AutoCAD SHX Text
SWITCH FOR EF-3 MANUAL OVERRIDE
AutoCAD SHX Text
S
AutoCAD SHX Text
SWITCH FOR EF-3 MANUAL OVERRIDE
AutoCAD SHX Text
HVAC PLAN
AutoCAD SHX Text
M2
AutoCAD SHX Text
PH.: (905) 946 4260 FAX: (905) 946 0901
AutoCAD SHX Text
MARKHAM ONTARIO L3R 1A3
AutoCAD SHX Text
UNIT 229
AutoCAD SHX Text
7181 WOODBINE AVE
AutoCAD SHX Text
%%UTHOMAS A. FEKETE LIMITED

B C D

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

AE

2

C A

4

3

DB

1

ELEC PANEL VFD CABINET

ROOF PLAN1

DATE INITIALREVISIONSNo.

DESIGN

DATE:

DRAWNCHECKED

DRAWING NUMBER

SIGNED

SCALE: CONTRACT No.

2019-11-01 ISSUED FOR 60% CONSTRUCTION DOCUMENTS1

WS2492514132

CITY ASSET No. 297

DUFFERIN GROVE PARK NORTH-WEST CORNER

AND CLUBHOUSE IMPROVEMENTS

DR

AW

IN

G P

RIN

T D

AT

E: 7/10/2020 5:03:13 P

M

FIL

EN

AM

E: \\T

AF

_S

ER

VE

R\taf_m

ain

\P

ro

jects\C

urren

t P

ro

jects\18173 D

UF

FE

RIN

G

RO

VE

P

AR

K IM

PR

OV

EM

EN

TS

\300 D

esig

n\301 M

E D

wg

s\18173 M

EC

H\18173

m m

etric.d

wg

YA YA BZ

JOB NUMBER: 18173

2020-01-17 ISSUED FOR 90% COORDINATION2

2020-02-14 PROGRESS SET3

2020-03-06 ISSUED FOR PERMIT4

2020-03-06

2020-03-24 ISSUED FOR CD'S5

2020-06-12

2020-06-12 ISSUED FOR TENDER6

AutoCAD SHX Text
G
AutoCAD SHX Text
TO RTU-2
AutoCAD SHX Text
TO MUA-1
AutoCAD SHX Text
MUA-1
AutoCAD SHX Text
EF-1
AutoCAD SHX Text
AIRFLOW
AutoCAD SHX Text
RTU-1 7.5 TON
AutoCAD SHX Text
EF-2
AutoCAD SHX Text
75 WASHROOM VENT
AutoCAD SHX Text
150 SKATESTORAGE EXHAUST
AutoCAD SHX Text
75 VENT
AutoCAD SHX Text
SCALE : 1:100
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
EF-3
AutoCAD SHX Text
EF-4
AutoCAD SHX Text
RD-4
AutoCAD SHX Text
RD-5
AutoCAD SHX Text
RD-3
AutoCAD SHX Text
RD-2
AutoCAD SHX Text
RD-1
AutoCAD SHX Text
ROOF DRAIN LOADS
AutoCAD SHX Text
ROOF DRAIN TAG
AutoCAD SHX Text
MAXIMUM FLOW (US GPM)
AutoCAD SHX Text
RD-1
AutoCAD SHX Text
COVERED AREA (SQFT)
AutoCAD SHX Text
RD-2
AutoCAD SHX Text
RD-3
AutoCAD SHX Text
RD-4
AutoCAD SHX Text
RD-5
AutoCAD SHX Text
667.4
AutoCAD SHX Text
20.6
AutoCAD SHX Text
656.6
AutoCAD SHX Text
20.6
AutoCAD SHX Text
1087.2
AutoCAD SHX Text
22.2
AutoCAD SHX Text
549.0
AutoCAD SHX Text
20.6
AutoCAD SHX Text
549.0
AutoCAD SHX Text
20.6
AutoCAD SHX Text
RTU-2 2.0 TON
AutoCAD SHX Text
100 DRYER VENT
AutoCAD SHX Text
75 VENT
AutoCAD SHX Text
75 VENT
AutoCAD SHX Text
G
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
CONCENTRIC VENT KIT FOR HWT-1
AutoCAD SHX Text
TOWARDS ZAMBONI GARAGE
AutoCAD SHX Text
GOOSE NECK
AutoCAD SHX Text
38
AutoCAD SHX Text
25
AutoCAD SHX Text
19
AutoCAD SHX Text
19
AutoCAD SHX Text
50
AutoCAD SHX Text
HIGH ROOF EDGE
AutoCAD SHX Text
38
AutoCAD SHX Text
ROOF PLAN
AutoCAD SHX Text
M3
AutoCAD SHX Text
PH.: (905) 946 4260 FAX: (905) 946 0901
AutoCAD SHX Text
MARKHAM ONTARIO L3R 1A3
AutoCAD SHX Text
UNIT 229
AutoCAD SHX Text
7181 WOODBINE AVE
AutoCAD SHX Text
%%UTHOMAS A. FEKETE LIMITED

B C D

1

2

3

4

5

6

7

8

9

10

AE

PLUMBING CODED NOTES:

DATE INITIALREVISIONSNo.

DESIGN

DATE:

DRAWNCHECKED

DRAWING NUMBER

SIGNED

SCALE: CONTRACT No.

2019-11-01 ISSUED FOR 60% CONSTRUCTION DOCUMENTS1

WS2492514132

CITY ASSET No. 297

DUFFERIN GROVE PARK NORTH-WEST CORNER

AND CLUBHOUSE IMPROVEMENTS

DR

AW

IN

G P

RIN

T D

AT

E: 7/10/2020 5:08:45 P

M

FIL

EN

AM

E: \\T

AF

_S

ER

VE

R\taf_m

ain

\P

ro

jects\C

urren

t P

ro

jects\18173 D

UF

FE

RIN

G

RO

VE

P

AR

K IM

PR

OV

EM

EN

TS

\300 D

esig

n\301 M

E D

wg

s\18173 M

EC

H\18173

m m

etric.d

wg

YA YA BZ

JOB NUMBER: 18173

2020-01-17 ISSUED FOR 90% COORDINATION2

2020-02-14 PROGRESS SET3

2020-03-06 ISSUED FOR PERMIT4

2020-03-06

2020-03-24 ISSUED FOR CD'S5

2020-06-12

2020-06-12 ISSUED FOR TENDER6

B C D

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

A

E

2

C A

4

3

DB

1

PLUMBING PLAN-11

AutoCAD SHX Text
M
AutoCAD SHX Text
VEST
AutoCAD SHX Text
001
AutoCAD SHX Text
MECH
AutoCAD SHX Text
003
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
004
AutoCAD SHX Text
CRP OFFICE
AutoCAD SHX Text
015
AutoCAD SHX Text
JC
AutoCAD SHX Text
012
AutoCAD SHX Text
COMMS
AutoCAD SHX Text
011
AutoCAD SHX Text
CIRCULATION
AutoCAD SHX Text
005
AutoCAD SHX Text
REFRIGERATION
AutoCAD SHX Text
002
AutoCAD SHX Text
U-WC
AutoCAD SHX Text
010
AutoCAD SHX Text
WC
AutoCAD SHX Text
009
AutoCAD SHX Text
WC
AutoCAD SHX Text
008
AutoCAD SHX Text
WC
AutoCAD SHX Text
007
AutoCAD SHX Text
WC
AutoCAD SHX Text
006
AutoCAD SHX Text
MULTI-PURPOSE
AutoCAD SHX Text
013
AutoCAD SHX Text
M
AutoCAD SHX Text
BFP
AutoCAD SHX Text
WATER METER
AutoCAD SHX Text
HWT-1
AutoCAD SHX Text
DN FROM ROOF
AutoCAD SHX Text
RUN BELOW TRENCH
AutoCAD SHX Text
DN TO HWT-1
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
38%%C DHW
AutoCAD SHX Text
50%%C DCW
AutoCAD SHX Text
50%%CDCW
AutoCAD SHX Text
DN TO GAS FIRE PLACE
AutoCAD SHX Text
CTE
AutoCAD SHX Text
1
AutoCAD SHX Text
100%%C
AutoCAD SHX Text
63%%C
AutoCAD SHX Text
TSP
AutoCAD SHX Text
TSP
AutoCAD SHX Text
TSP
AutoCAD SHX Text
13%%C DHWR
AutoCAD SHX Text
19%%CDHW
AutoCAD SHX Text
CONNECT TO EXISTING BOTTLE FILLING STATION & HOSE BIB
AutoCAD SHX Text
EW
AutoCAD SHX Text
NFHB
AutoCAD SHX Text
EW
AutoCAD SHX Text
HOSE BIB (TYPICAL FOR ALL WASHROOM)
AutoCAD SHX Text
HB
AutoCAD SHX Text
WASHER WALL BOX
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
4
AutoCAD SHX Text
6
AutoCAD SHX Text
6
AutoCAD SHX Text
10
AutoCAD SHX Text
38
AutoCAD SHX Text
19
AutoCAD SHX Text
32
AutoCAD SHX Text
MATCH LINE
AutoCAD SHX Text
25
AutoCAD SHX Text
CTE
AutoCAD SHX Text
CTE
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
LAVATORY
AutoCAD SHX Text
HB
AutoCAD SHX Text
SK-1
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
4
AutoCAD SHX Text
3
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
SUPPLY AND INSTALL NEW FLUSH VALVE TOILETS. CONNECT 25 WATER PIPE DOWN TOTHE FLUSH VALVE INLET. (TYPICAL FOR ALL) SUPPLY AND INSTALL NEW LAVATORIES. SUPPLY AND INSTALL NEW LAVATORIES. CONNECT TO 13 DCW AND DHW AS INDICATED ON THE DRAWING. SUPPLY AND INSTALLINTERIOR HOSE BIB IN EACH WASHROOM.
AutoCAD SHX Text
#
AutoCAD SHX Text
PLUMBING AND DRAINAGE GENERAL NOTES
AutoCAD SHX Text
NEW SANITARY LINE SHALL BE PRESSURE TESTED PER LOCAL CODES WITH A MINIMUM REQUIREMENT OF HOLDING 10 FT W.C. FOR 2 (TWO) HOURS.
AutoCAD SHX Text
FURNISH AND INSTALL WATER HAMMER ARRESTORS IN THE DOMESTIC COLD AND HOT WATER PIPING. WATER HAMMER ARRESTORS TO BE LOCATED IN AN ACCESSIBLE LOCATION. UNITS AS MANUFACTURED BY SIOUX OR PRECISION PLUMBING PRODUCTS ARE ACCEPTABLE.
AutoCAD SHX Text
ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOP VALVES TO ISOLATE EACH FIXTURE. REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR FUTURE INFORMATION.
AutoCAD SHX Text
FUR OUT DEMISING WALL FOR PLUMBING FIXTURES INSTALLATION.
AutoCAD SHX Text
PLUMBING CONTRACTOR TO VERIFY ALL CONDITIONS IN THE FIELD PRIOR TO BIDDING WORK. ANY CONDITIONS THAT AFFECT THE INSTALLATION OF THIS PROJECT MUST IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE CONSTRUCTION MANAGER OR BE INCORPORATED IN THE BID.
AutoCAD SHX Text
ALL PIPING WILL BE COPPER OR CAST IRON. ALL PIPING WILL BE PROPERLY HUNG AND SECURED TO AVOID MOVEMENT. DO NOT USE 90° FITTINGS ON TURNS.
AutoCAD SHX Text
SLAB SHALL BE X-RAY SCANNED PRIOR TO CORE DRILLING AND BE FIRE-STOPPED AND WATER-PROOF BY THIS CONTRACTOR. ALLOW FOR AFTER-HOUR X-RAY AND SCANNING FOR ANY CORING/SLAB PENETRATIONS REQUIRED.
AutoCAD SHX Text
WASHROOM FIXTURES TO BE COMMERCIAL GRADE AND ENERGY EFFICIENT (LOW CONSUMPTION MODEL).
AutoCAD SHX Text
PROVIDE ADEQUATE ACCESS TO MAIN DCW ISOLATION VALVE.
AutoCAD SHX Text
COORDINATE ALL UNDER FLOOR PLUMBING WITH EXISTING SERVICES BELOW.
AutoCAD SHX Text
USE GALVANIZED STEEL FOR PUMPED SANITARY IN ACCORDANCE WITH ASTM A53/A53M, NATURAL GAS USE STEEL PIPE: ASTM A53,S CHEDULE 40, GRADE B SEAMLESS.
AutoCAD SHX Text
SUPPLY AND INSTALL NEW INTERIOR HOSE BIB AS INDICATED ON THE DRAWING. CONNECT TO 13 DCW. COORDINATE WITH ARCHITECTURAL DRAWING FOR EXACT LOCATION.
AutoCAD SHX Text
SUPPLY AND INSTALL TRAP PRIMER FOR ALL FLOOR DRAINS.
AutoCAD SHX Text
SUPPLY AND INSTALL EYEWASH STATIONS AS INDICATED ON THE DRAWING. ALL EYEWASH STATIONS SHALL BE SUPPLIED THROUGH TEMPERED MIXING VALVES.
AutoCAD SHX Text
SUPPLY AND INSTALL DISHWASHER. CONNECT DCW&DHW AS REQUIRED.
AutoCAD SHX Text
SUPPLY AND INSTALL NON FREEZE HOSE BIB ALONG THE EXTERIOR WALL AS INDICATED. COMPLETE WITH LOCKABLE COVER FOR ALL THE HOSE BIBS (EXISTING OR NEW).
AutoCAD SHX Text
SUPPLY AND INSTALL FUEL MAKER STATION FOR THE ZAMBONI. REFER TO MANUFACTURER INSTALLATION MANUAL FOR DETAILS.
AutoCAD SHX Text
8
AutoCAD SHX Text
RUN DCW&DHW WATER PIPE DOWN THROUGH THE SHAFT WALL AND FEED FIXTURES BY RUNNING THE PIPES BEHIND THE COUNTER WITHIN A CHASE.
AutoCAD SHX Text
9
AutoCAD SHX Text
REFER TO L201 FOR EXACT LOCATION OF THE BOTTLE FILLING LOCATION.
AutoCAD SHX Text
10
AutoCAD SHX Text
FOR THE HOT WATER TANKS, COMPLETE WITH 150 CONCENTRIC TERMINATION FOREXHAUST AND AIR INTAKE. HOT WATER TANK-1, TERMINATES ON ROOM. REFER TO DETAIL 12. FOR HOT WATER TANK-2, TERMINATES AT THE SIDE WALL AS HIGH AS POSSIBLE. REFER TO DETAIL 11.
AutoCAD SHX Text
NEW SOLENOID GAS SHUT OFF VALVE. INTERLOCKED WITH KITCHEN FIRE SUPPRESSION SYSTEM. ENSURE GAS RISER IS LOCATED WITHIN STAINLESS WALL. ONLY SHUT OFF VALVE IS EXPOSED AT THE END OF THE WALL.
AutoCAD SHX Text
11
AutoCAD SHX Text
SUPPLY AND INSTALL NEW BOTTLE FILLER AS INDICATED ON THE DRAWING. COORDINATE WITH ARCHITECT INTERIOR ELEVATION FOR EXACT LOCATION.
AutoCAD SHX Text
12
AutoCAD SHX Text
SUPPLY AND INSTALL UNDERGROUND WATER LINE TOWARDS THE BOTTLE FILLING STATION NEXT TO THE HOCKEY RINK. COORDINATE WITH SITE PLAN ON EXACT LOCATION OF THE BOTTLE FILLING STATION.
AutoCAD SHX Text
13
AutoCAD SHX Text
SUPPLY AND INSTALL 1" HOT WATER HOSE BIBB FOR THE SNOW MELTING PIT. OUTLET SIZE SHALL BE 25MM. COMPLETE WITH SHUT OFF VALVE.
AutoCAD SHX Text
14
AutoCAD SHX Text
PLUMBING PLAN-1
AutoCAD SHX Text
M4.1
AutoCAD SHX Text
PH.: (905) 946 4260 FAX: (905) 946 0901
AutoCAD SHX Text
MARKHAM ONTARIO L3R 1A3
AutoCAD SHX Text
UNIT 229
AutoCAD SHX Text
7181 WOODBINE AVE
AutoCAD SHX Text
%%UTHOMAS A. FEKETE LIMITED
AutoCAD SHX Text
M
AutoCAD SHX Text
VEST
AutoCAD SHX Text
001
AutoCAD SHX Text
MECH
AutoCAD SHX Text
003
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
004
AutoCAD SHX Text
STAFF
AutoCAD SHX Text
018
AutoCAD SHX Text
POS
AutoCAD SHX Text
016
AutoCAD SHX Text
CRP OFFICE
AutoCAD SHX Text
015
AutoCAD SHX Text
JC
AutoCAD SHX Text
012
AutoCAD SHX Text
COMMS
AutoCAD SHX Text
011
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
020
AutoCAD SHX Text
CIRCULATION
AutoCAD SHX Text
005
AutoCAD SHX Text
REFRIGERATION
AutoCAD SHX Text
002
AutoCAD SHX Text
U-WC
AutoCAD SHX Text
010
AutoCAD SHX Text
WC
AutoCAD SHX Text
009
AutoCAD SHX Text
WC
AutoCAD SHX Text
008
AutoCAD SHX Text
WC
AutoCAD SHX Text
007
AutoCAD SHX Text
WC
AutoCAD SHX Text
006
AutoCAD SHX Text
MULTI-PURPOSE
AutoCAD SHX Text
014
AutoCAD SHX Text
MULTI-PURPOSE
AutoCAD SHX Text
013
AutoCAD SHX Text
SKATES
AutoCAD SHX Text
017
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
019
AutoCAD SHX Text
1:50
AutoCAD SHX Text
KEY PLAN (NTS)

PLUMBING CODED NOTES:

9

10

11

12

13

14

15

16

17

18

19

DATE INITIALREVISIONSNo.

DESIGN

DATE:

DRAWNCHECKED

DRAWING NUMBER

SIGNED

SCALE: CONTRACT No.

2019-11-01 ISSUED FOR 60% CONSTRUCTION DOCUMENTS1

WS2492514132

CITY ASSET No. 297

DUFFERIN GROVE PARK NORTH-WEST CORNER

AND CLUBHOUSE IMPROVEMENTS

DR

AW

IN

G P

RIN

T D

AT

E: 7/10/2020 5:08:53 P

M

FIL

EN

AM

E: \\T

AF

_S

ER

VE

R\taf_m

ain

\P

ro

jects\C

urren

t P

ro

jects\18173 D

UF

FE

RIN

G

RO

VE

P

AR

K IM

PR

OV

EM

EN

TS

\300 D

esig

n\301 M

E D

wg

s\18173 M

EC

H\18173

m m

etric.d

wg

YA YA BZ

JOB NUMBER: 18173

2020-01-17 ISSUED FOR 90% COORDINATION2

2020-02-14 PROGRESS SET3

2020-03-06 ISSUED FOR PERMIT4

2020-03-06

2020-03-24 ISSUED FOR CD'S5

2020-06-12

2020-06-12 ISSUED FOR TENDER6

B C D

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

A

E

2

C A

4

3

DB

1

PLUMBING PLAN-21

AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
4
AutoCAD SHX Text
3
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
SUPPLY AND INSTALL NEW FLUSH VALVE TOILETS. CONNECT 25 WATER PIPE DOWN TOTHE FLUSH VALVE INLET. (TYPICAL FOR ALL) SUPPLY AND INSTALL NEW LAVATORIES. SUPPLY AND INSTALL NEW LAVATORIES. CONNECT TO 13 DCW AND DHW AS INDICATED ON THE DRAWING. SUPPLY AND INSTALLINTERIOR HOSE BIB IN EACH WASHROOM.
AutoCAD SHX Text
#
AutoCAD SHX Text
PLUMBING AND DRAINAGE GENERAL NOTES
AutoCAD SHX Text
NEW SANITARY LINE SHALL BE PRESSURE TESTED PER LOCAL CODES WITH A MINIMUM REQUIREMENT OF HOLDING 10 FT W.C. FOR 2 (TWO) HOURS.
AutoCAD SHX Text
FURNISH AND INSTALL WATER HAMMER ARRESTORS IN THE DOMESTIC COLD AND HOT WATER PIPING. WATER HAMMER ARRESTORS TO BE LOCATED IN AN ACCESSIBLE LOCATION. UNITS AS MANUFACTURED BY SIOUX OR PRECISION PLUMBING PRODUCTS ARE ACCEPTABLE.
AutoCAD SHX Text
ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOP VALVES TO ISOLATE EACH FIXTURE. REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR FUTURE INFORMATION.
AutoCAD SHX Text
FUR OUT DEMISING WALL FOR PLUMBING FIXTURES INSTALLATION.
AutoCAD SHX Text
PLUMBING CONTRACTOR TO VERIFY ALL CONDITIONS IN THE FIELD PRIOR TO BIDDING WORK. ANY CONDITIONS THAT AFFECT THE INSTALLATION OF THIS PROJECT MUST IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE CONSTRUCTION MANAGER OR BE INCORPORATED IN THE BID.
AutoCAD SHX Text
ALL PIPING WILL BE COPPER OR CAST IRON. ALL PIPING WILL BE PROPERLY HUNG AND SECURED TO AVOID MOVEMENT. DO NOT USE 90° FITTINGS ON TURNS.
AutoCAD SHX Text
SLAB SHALL BE X-RAY SCANNED PRIOR TO CORE DRILLING AND BE FIRE-STOPPED AND WATER-PROOF BY THIS CONTRACTOR. ALLOW FOR AFTER-HOUR X-RAY AND SCANNING FOR ANY CORING/SLAB PENETRATIONS REQUIRED.
AutoCAD SHX Text
WASHROOM FIXTURES TO BE COMMERCIAL GRADE AND ENERGY EFFICIENT (LOW CONSUMPTION MODEL).
AutoCAD SHX Text
PROVIDE ADEQUATE ACCESS TO MAIN DCW ISOLATION VALVE.
AutoCAD SHX Text
COORDINATE ALL UNDER FLOOR PLUMBING WITH EXISTING SERVICES BELOW.
AutoCAD SHX Text
USE GALVANIZED STEEL FOR PUMPED SANITARY IN ACCORDANCE WITH ASTM A53/A53M, NATURAL GAS USE STEEL PIPE: ASTM A53,S CHEDULE 40, GRADE B SEAMLESS.
AutoCAD SHX Text
SUPPLY AND INSTALL NEW INTERIOR HOSE BIB AS INDICATED ON THE DRAWING. CONNECT TO 13 DCW. COORDINATE WITH ARCHITECTURAL DRAWING FOR EXACT LOCATION.
AutoCAD SHX Text
SUPPLY AND INSTALL TRAP PRIMER FOR ALL FLOOR DRAINS.
AutoCAD SHX Text
SUPPLY AND INSTALL EYEWASH STATIONS AS INDICATED ON THE DRAWING. ALL EYEWASH STATIONS SHALL BE SUPPLIED THROUGH TEMPERED MIXING VALVES.
AutoCAD SHX Text
SUPPLY AND INSTALL DISHWASHER. CONNECT DCW&DHW AS REQUIRED.
AutoCAD SHX Text
SUPPLY AND INSTALL NON FREEZE HOSE BIB ALONG THE EXTERIOR WALL AS INDICATED. COMPLETE WITH LOCKABLE COVER FOR ALL THE HOSE BIBS (EXISTING OR NEW).
AutoCAD SHX Text
SUPPLY AND INSTALL FUEL MAKER STATION FOR THE ZAMBONI. REFER TO MANUFACTURER INSTALLATION MANUAL FOR DETAILS.
AutoCAD SHX Text
8
AutoCAD SHX Text
RUN DCW&DHW WATER PIPE DOWN THROUGH THE SHAFT WALL AND FEED FIXTURES BY RUNNING THE PIPES BEHIND THE COUNTER WITHIN A CHASE.
AutoCAD SHX Text
9
AutoCAD SHX Text
REFER TO L201 FOR EXACT LOCATION OF THE BOTTLE FILLING LOCATION.
AutoCAD SHX Text
10
AutoCAD SHX Text
FOR THE HOT WATER TANKS, COMPLETE WITH 150 CONCENTRIC TERMINATION FOREXHAUST AND AIR INTAKE. HOT WATER TANK-1, TERMINATES ON ROOM. REFER TO DETAIL 12. FOR HOT WATER TANK-2, TERMINATES AT THE SIDE WALL AS HIGH AS POSSIBLE. REFER TO DETAIL 11.
AutoCAD SHX Text
NEW SOLENOID GAS SHUT OFF VALVE. INTERLOCKED WITH KITCHEN FIRE SUPPRESSION SYSTEM. ENSURE GAS RISER IS LOCATED WITHIN STAINLESS WALL. ONLY SHUT OFF VALVE IS EXPOSED AT THE END OF THE WALL.
AutoCAD SHX Text
11
AutoCAD SHX Text
SUPPLY AND INSTALL NEW BOTTLE FILLER AS INDICATED ON THE DRAWING. COORDINATE WITH ARCHITECT INTERIOR ELEVATION FOR EXACT LOCATION.
AutoCAD SHX Text
12
AutoCAD SHX Text
SUPPLY AND INSTALL UNDERGROUND WATER LINE TOWARDS THE BOTTLE FILLING STATION NEXT TO THE HOCKEY RINK. COORDINATE WITH SITE PLAN ON EXACT LOCATION OF THE BOTTLE FILLING STATION.
AutoCAD SHX Text
13
AutoCAD SHX Text
SUPPLY AND INSTALL 1" HOT WATER HOSE BIBB FOR THE SNOW MELTING PIT. OUTLET SIZE SHALL BE 25MM. COMPLETE WITH SHUT OFF VALVE.
AutoCAD SHX Text
14
AutoCAD SHX Text
STAFF
AutoCAD SHX Text
018
AutoCAD SHX Text
POS
AutoCAD SHX Text
016
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
020
AutoCAD SHX Text
MULTI-PURPOSE
AutoCAD SHX Text
014
AutoCAD SHX Text
MULTI-PURPOSE
AutoCAD SHX Text
013
AutoCAD SHX Text
SKATES
AutoCAD SHX Text
017
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
019
AutoCAD SHX Text
GAS METER
AutoCAD SHX Text
M
AutoCAD SHX Text
50 UP
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
TSP
AutoCAD SHX Text
NFHB WITH LOCKABLE COVER.
AutoCAD SHX Text
DW
AutoCAD SHX Text
EW
AutoCAD SHX Text
HB
AutoCAD SHX Text
WF
AutoCAD SHX Text
HB
AutoCAD SHX Text
32 UP
AutoCAD SHX Text
G
AutoCAD SHX Text
IN CEILING
AutoCAD SHX Text
TO GAS RANGE
AutoCAD SHX Text
WASHER &DRYER
AutoCAD SHX Text
WASHER WALL BOX
AutoCAD SHX Text
EW
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
4
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
DN
AutoCAD SHX Text
8
AutoCAD SHX Text
32
AutoCAD SHX Text
19
AutoCAD SHX Text
32
AutoCAD SHX Text
MATCH LINE
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13 DCW BELOW GRADETOWARDS BF STATION
AutoCAD SHX Text
SK-1
AutoCAD SHX Text
SK-1
AutoCAD SHX Text
SK-2
AutoCAD SHX Text
SK-3
AutoCAD SHX Text
PLUMBING PLAN-2
AutoCAD SHX Text
M4.2
AutoCAD SHX Text
PH.: (905) 946 4260 FAX: (905) 946 0901
AutoCAD SHX Text
MARKHAM ONTARIO L3R 1A3
AutoCAD SHX Text
UNIT 229
AutoCAD SHX Text
7181 WOODBINE AVE
AutoCAD SHX Text
%%UTHOMAS A. FEKETE LIMITED
AutoCAD SHX Text
M
AutoCAD SHX Text
VEST
AutoCAD SHX Text
001
AutoCAD SHX Text
MECH
AutoCAD SHX Text
003
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
004
AutoCAD SHX Text
STAFF
AutoCAD SHX Text
018
AutoCAD SHX Text
POS
AutoCAD SHX Text
016
AutoCAD SHX Text
CRP OFFICE
AutoCAD SHX Text
015
AutoCAD SHX Text
JC
AutoCAD SHX Text
012
AutoCAD SHX Text
COMMS
AutoCAD SHX Text
011
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
020
AutoCAD SHX Text
CIRCULATION
AutoCAD SHX Text
005
AutoCAD SHX Text
REFRIGERATION
AutoCAD SHX Text
002
AutoCAD SHX Text
U-WC
AutoCAD SHX Text
010
AutoCAD SHX Text
WC
AutoCAD SHX Text
009
AutoCAD SHX Text
WC
AutoCAD SHX Text
008
AutoCAD SHX Text
WC
AutoCAD SHX Text
007
AutoCAD SHX Text
WC
AutoCAD SHX Text
006
AutoCAD SHX Text
MULTI-PURPOSE
AutoCAD SHX Text
014
AutoCAD SHX Text
MULTI-PURPOSE
AutoCAD SHX Text
013
AutoCAD SHX Text
SKATES
AutoCAD SHX Text
017
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
019
AutoCAD SHX Text
1:50
AutoCAD SHX Text
KEY PLAN (NTS)

2

C A

4

3

DB

1

PLUMBING PLAN-31

PLUMBING CODED NOTES:

DATE INITIALREVISIONSNo.

DESIGN

DATE:

DRAWNCHECKED

DRAWING NUMBER

SIGNED

SCALE: CONTRACT No.

2019-11-01 ISSUED FOR 60% CONSTRUCTION DOCUMENTS1

WS2492514132

CITY ASSET No. 297

DUFFERIN GROVE PARK NORTH-WEST CORNER

AND CLUBHOUSE IMPROVEMENTS

DR

AW

IN

G P

RIN

T D

AT

E: 7/10/2020 5:09:04 P

M

FIL

EN

AM

E: \\T

AF

_S

ER

VE

R\taf_m

ain

\P

ro

jects\C

urren

t P

ro

jects\18173 D

UF

FE

RIN

G

RO

VE

P

AR

K IM

PR

OV

EM

EN

TS

\300 D

esig

n\301 M

E D

wg

s\18173 M

EC

H\18173

m m

etric.d

wg

YA YA BZ

JOB NUMBER: 18173

2020-01-17 ISSUED FOR 90% COORDINATION2

2020-02-14 PROGRESS SET3

2020-03-06 ISSUED FOR PERMIT4

2020-03-06

2020-03-24 ISSUED FOR CD'S5

2020-06-12

2020-06-12 ISSUED FOR TENDER6

B C D

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

A

E

2

C A

4

3

DB

1

AutoCAD SHX Text
HWT-2
AutoCAD SHX Text
UP
AutoCAD SHX Text
TOWARDS HWT-2 AND UNIT HEATER
AutoCAD SHX Text
BFP
AutoCAD SHX Text
EW
AutoCAD SHX Text
ZAMBONI FUEL MAKER
AutoCAD SHX Text
REMOTE FUELING PANEL
AutoCAD SHX Text
MIXING VALVE
AutoCAD SHX Text
WATER FILL STATION
AutoCAD SHX Text
4
AutoCAD SHX Text
7
AutoCAD SHX Text
NFHB
AutoCAD SHX Text
6
AutoCAD SHX Text
10
AutoCAD SHX Text
SCALE : 1:50
AutoCAD SHX Text
UH-1
AutoCAD SHX Text
32%%C
AutoCAD SHX Text
19%%C
AutoCAD SHX Text
25%%C
AutoCAD SHX Text
13%%C
AutoCAD SHX Text
13%%C
AutoCAD SHX Text
19%%C
AutoCAD SHX Text
19%%C
AutoCAD SHX Text
25%%C
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
4
AutoCAD SHX Text
3
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
SUPPLY AND INSTALL NEW FLUSH VALVE TOILETS. CONNECT 25 WATER PIPE DOWN TOTHE FLUSH VALVE INLET. (TYPICAL FOR ALL) SUPPLY AND INSTALL NEW LAVATORIES. SUPPLY AND INSTALL NEW LAVATORIES. CONNECT TO 13 DCW AND DHW AS INDICATED ON THE DRAWING. SUPPLY AND INSTALLINTERIOR HOSE BIB IN EACH WASHROOM.
AutoCAD SHX Text
#
AutoCAD SHX Text
PLUMBING AND DRAINAGE GENERAL NOTES
AutoCAD SHX Text
NEW SANITARY LINE SHALL BE PRESSURE TESTED PER LOCAL CODES WITH A MINIMUM REQUIREMENT OF HOLDING 10 FT W.C. FOR 2 (TWO) HOURS.
AutoCAD SHX Text
FURNISH AND INSTALL WATER HAMMER ARRESTORS IN THE DOMESTIC COLD AND HOT WATER PIPING. WATER HAMMER ARRESTORS TO BE LOCATED IN AN ACCESSIBLE LOCATION. UNITS AS MANUFACTURED BY SIOUX OR PRECISION PLUMBING PRODUCTS ARE ACCEPTABLE.
AutoCAD SHX Text
ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOP VALVES TO ISOLATE EACH FIXTURE. REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR FUTURE INFORMATION.
AutoCAD SHX Text
FUR OUT DEMISING WALL FOR PLUMBING FIXTURES INSTALLATION.
AutoCAD SHX Text
PLUMBING CONTRACTOR TO VERIFY ALL CONDITIONS IN THE FIELD PRIOR TO BIDDING WORK. ANY CONDITIONS THAT AFFECT THE INSTALLATION OF THIS PROJECT MUST IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE CONSTRUCTION MANAGER OR BE INCORPORATED IN THE BID.
AutoCAD SHX Text
ALL PIPING WILL BE COPPER OR CAST IRON. ALL PIPING WILL BE PROPERLY HUNG AND SECURED TO AVOID MOVEMENT. DO NOT USE 90° FITTINGS ON TURNS.
AutoCAD SHX Text
SLAB SHALL BE X-RAY SCANNED PRIOR TO CORE DRILLING AND BE FIRE-STOPPED AND WATER-PROOF BY THIS CONTRACTOR. ALLOW FOR AFTER-HOUR X-RAY AND SCANNING FOR ANY CORING/SLAB PENETRATIONS REQUIRED.
AutoCAD SHX Text
WASHROOM FIXTURES TO BE COMMERCIAL GRADE AND ENERGY EFFICIENT (LOW CONSUMPTION MODEL).
AutoCAD SHX Text
PROVIDE ADEQUATE ACCESS TO MAIN DCW ISOLATION VALVE.
AutoCAD SHX Text
COORDINATE ALL UNDER FLOOR PLUMBING WITH EXISTING SERVICES BELOW.
AutoCAD SHX Text
USE GALVANIZED STEEL FOR PUMPED SANITARY IN ACCORDANCE WITH ASTM A53/A53M, NATURAL GAS USE STEEL PIPE: ASTM A53,S CHEDULE 40, GRADE B SEAMLESS.
AutoCAD SHX Text
SUPPLY AND INSTALL NEW INTERIOR HOSE BIB AS INDICATED ON THE DRAWING. CONNECT TO 13 DCW. COORDINATE WITH ARCHITECTURAL DRAWING FOR EXACT LOCATION.
AutoCAD SHX Text
SUPPLY AND INSTALL TRAP PRIMER FOR ALL FLOOR DRAINS.
AutoCAD SHX Text
SUPPLY AND INSTALL EYEWASH STATIONS AS INDICATED ON THE DRAWING. ALL EYEWASH STATIONS SHALL BE SUPPLIED THROUGH TEMPERED MIXING VALVES.
AutoCAD SHX Text
SUPPLY AND INSTALL DISHWASHER. CONNECT DCW&DHW AS REQUIRED.
AutoCAD SHX Text
SUPPLY AND INSTALL NON FREEZE HOSE BIB ALONG THE EXTERIOR WALL AS INDICATED. COMPLETE WITH LOCKABLE COVER FOR ALL THE HOSE BIBS (EXISTING OR NEW).
AutoCAD SHX Text
SUPPLY AND INSTALL FUEL MAKER STATION FOR THE ZAMBONI. REFER TO MANUFACTURER INSTALLATION MANUAL FOR DETAILS.
AutoCAD SHX Text
8
AutoCAD SHX Text
RUN DCW&DHW WATER PIPE DOWN THROUGH THE SHAFT WALL AND FEED FIXTURES BY RUNNING THE PIPES BEHIND THE COUNTER WITHIN A CHASE.
AutoCAD SHX Text
9
AutoCAD SHX Text
REFER TO L201 FOR EXACT LOCATION OF THE BOTTLE FILLING LOCATION.
AutoCAD SHX Text
10
AutoCAD SHX Text
FOR THE HOT WATER TANKS, COMPLETE WITH 150 CONCENTRIC TERMINATION FOREXHAUST AND AIR INTAKE. HOT WATER TANK-1, TERMINATES ON ROOM. REFER TO DETAIL 12. FOR HOT WATER TANK-2, TERMINATES AT THE SIDE WALL AS HIGH AS POSSIBLE. REFER TO DETAIL 11.
AutoCAD SHX Text
NEW SOLENOID GAS SHUT OFF VALVE. INTERLOCKED WITH KITCHEN FIRE SUPPRESSION SYSTEM. ENSURE GAS RISER IS LOCATED WITHIN STAINLESS WALL. ONLY SHUT OFF VALVE IS EXPOSED AT THE END OF THE WALL.
AutoCAD SHX Text
11
AutoCAD SHX Text
SUPPLY AND INSTALL NEW BOTTLE FILLER AS INDICATED ON THE DRAWING. COORDINATE WITH ARCHITECT INTERIOR ELEVATION FOR EXACT LOCATION.
AutoCAD SHX Text
12
AutoCAD SHX Text
SUPPLY AND INSTALL UNDERGROUND WATER LINE TOWARDS THE BOTTLE FILLING STATION NEXT TO THE HOCKEY RINK. COORDINATE WITH SITE PLAN ON EXACT LOCATION OF THE BOTTLE FILLING STATION.
AutoCAD SHX Text
13
AutoCAD SHX Text
SUPPLY AND INSTALL 1" HOT WATER HOSE BIBB FOR THE SNOW MELTING PIT. OUTLET SIZE SHALL BE 25MM. COMPLETE WITH SHUT OFF VALVE.
AutoCAD SHX Text
14
AutoCAD SHX Text
PLUMBING PLAN-3
AutoCAD SHX Text
M4.3
AutoCAD SHX Text
PH.: (905) 946 4260 FAX: (905) 946 0901
AutoCAD SHX Text
MARKHAM ONTARIO L3R 1A3
AutoCAD SHX Text
UNIT 229
AutoCAD SHX Text
7181 WOODBINE AVE
AutoCAD SHX Text
%%UTHOMAS A. FEKETE LIMITED
AutoCAD SHX Text
M
AutoCAD SHX Text
VEST
AutoCAD SHX Text
001
AutoCAD SHX Text
MECH
AutoCAD SHX Text
003
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
004
AutoCAD SHX Text
STAFF
AutoCAD SHX Text
018
AutoCAD SHX Text
POS
AutoCAD SHX Text
016
AutoCAD SHX Text
CRP OFFICE
AutoCAD SHX Text
015
AutoCAD SHX Text
JC
AutoCAD SHX Text
012
AutoCAD SHX Text
COMMS
AutoCAD SHX Text
011
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
020
AutoCAD SHX Text
CIRCULATION
AutoCAD SHX Text
005
AutoCAD SHX Text
REFRIGERATION
AutoCAD SHX Text
002
AutoCAD SHX Text
U-WC
AutoCAD SHX Text
010
AutoCAD SHX Text
WC
AutoCAD SHX Text
009
AutoCAD SHX Text
WC
AutoCAD SHX Text
008
AutoCAD SHX Text
WC
AutoCAD SHX Text
007
AutoCAD SHX Text
WC
AutoCAD SHX Text
006
AutoCAD SHX Text
MULTI-PURPOSE
AutoCAD SHX Text
014
AutoCAD SHX Text
MULTI-PURPOSE
AutoCAD SHX Text
013
AutoCAD SHX Text
SKATES
AutoCAD SHX Text
017
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
019
AutoCAD SHX Text
KEY PLAN (NTS)

PLUMBING CODED NOTES:

B C D

1

2

3

4

5

6

7

8

9

10

AE

DATE INITIALREVISIONSNo.

DESIGN

DATE:

DRAWNCHECKED

DRAWING NUMBER

SIGNED

SCALE: CONTRACT No.

2019-11-01 ISSUED FOR 60% CONSTRUCTION DOCUMENTS1

WS2492514132

CITY ASSET No. 297

DUFFERIN GROVE PARK NORTH-WEST CORNER

AND CLUBHOUSE IMPROVEMENTS

DR

AW

IN

G P

RIN

T D

AT

E: 7/10/2020 5:09:14 P

M

FIL

EN

AM

E: \\T

AF

_S

ER

VE

R\taf_m

ain

\P

ro

jects\C

urren

t P

ro

jects\18173 D

UF

FE

RIN

G

RO

VE

P

AR

K IM

PR

OV

EM

EN

TS

\300 D

esig

n\301 M

E D

wg

s\18173 M

EC

H\18173

m m

etric.d

wg

YA YA BZ

JOB NUMBER: 18173

2020-01-17 ISSUED FOR 90% COORDINATION2

2020-02-14 PROGRESS SET3

2020-03-06 ISSUED FOR PERMIT4

2020-03-06

2020-03-24 ISSUED FOR CD'S5

2020-06-12

2020-06-12 ISSUED FOR TENDER6

B C D

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

A

E

2

C A

4

3

DB

1

DRAINAGE PLAN-11

AutoCAD SHX Text
1
AutoCAD SHX Text
#
AutoCAD SHX Text
PLUMBING AND DRAINAGE GENERAL NOTES
AutoCAD SHX Text
NEW SANITARY LINE SHALL BE PRESSURE TESTED PER LOCAL CODES WITH A MINIMUM REQUIREMENT OF HOLDING 10 FT W.C. FOR 2 (TWO) HOURS.
AutoCAD SHX Text
FURNISH AND INSTALL WATER HAMMER ARRESTORS IN THE DOMESTIC COLD AND HOT WATER PIPING. WATER HAMMER ARRESTORS TO BE LOCATED IN AN ACCESSIBLE LOCATION. UNITS AS MANUFACTURED BY SIOUX OR PRECISION PLUMBING PRODUCTS ARE ACCEPTABLE.
AutoCAD SHX Text
ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOP VALVES TO ISOLATE EACH FIXTURE. REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR FUTURE INFORMATION.
AutoCAD SHX Text
PROVIDE MIXING VALVE, MAX TEMP. SET POINT @ 110°F FOR TEMPEREDWATER AT LAVATORY FOR 1070 ANSI. FIELD VERIFY EXISTING CONDITIONS.
AutoCAD SHX Text
FUR OUT DEMISING WALL FOR PLUMBING FIXTURES INSTALLATION.
AutoCAD SHX Text
PLUMBING CONTRACTOR TO VERIFY ALL CONDITIONS IN THE FIELD PRIOR TO BIDDING WORK. ANY CONDITIONS THAT AFFECT THE INSTALLATION OF THIS PROJECT MUST IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE CONSTRUCTION MANAGER OR BE INCORPORATED IN THE BID.
AutoCAD SHX Text
ALL PIPING WILL BE COPPER OR CAST IRON. ALL PIPING WILL BE PROPERLY HUNG AND SECURED TO AVOID MOVEMENT. DO NOT USE 90° FITTINGS ON TURNS.
AutoCAD SHX Text
SLAB SHALL BE X-RAY SCANNED PRIOR TO CORE DRILLING AND BE FIRE-STOPPED AND WATER-PROOF BY THIS CONTRACTOR. ALLOW FOR AFTER-HOUR X-RAY AND SCANNING FOR ANY CORING/SLAB PENETRATIONS REQUIRED.
AutoCAD SHX Text
WASHROOM FIXTURES TO BE COMMERCIAL GRADE AND ENERGY EFFICIENT (LOW CONSUMPTION MODEL).
AutoCAD SHX Text
PROVIDE ADEQUATE ACCESS TO MAIN DCW ISOLATION VALVE.
AutoCAD SHX Text
COORDINATE ALL UNDER FLOOR PLUMBING WITH LANDLORD AND EXISTING SERVICES BELOW.
AutoCAD SHX Text
3"
AutoCAD SHX Text
SUPPLY AND INSTALL NEW FLUSH VALVE TOILETS. CONNECT 100 SANITARY AND 38 VENTPIPE. (TYPICAL FOR ALL) SUPPLY AND INSTALL NEW LAVATORIES. CONNECT TO 75 SUPPLY AND INSTALL NEW LAVATORIES. CONNECT TO 75 SANITARY AND 32 VENT AS INDICATED ON THE DRAWING. INSTALL FLOOR DRAIN WITHINEACH WASHROOM.
AutoCAD SHX Text
2
AutoCAD SHX Text
SUPPLY AND INSTALL NEW FLOOR DRAINS AS SHOWN ON THE PLAN. CONNECT TO 32 VENT PIPE. TIE INTO MAIN BRANCH AS INDICATED ON THE DRAWING.
AutoCAD SHX Text
3
AutoCAD SHX Text
SUPPLY AND INSTALL SINKS WITHIN THE KITCHEN. VENT AND SANITARY SHALL BE RUN THROUGH CAVITY BEHIND THE COUNTER.
AutoCAD SHX Text
4
AutoCAD SHX Text
SUPPLY AND INSTALL ROOF DRAINS AS INDICATED ON THE DRAWING.
AutoCAD SHX Text
5
AutoCAD SHX Text
SUPPLY AND INSTALL TRENCH DRAIN WITHIN THE ZAMBONI GARAGE. CONNECT TO SANITARY AND VENT AS NEEDED.
AutoCAD SHX Text
6
AutoCAD SHX Text
SUPPLY AND INSTALL SUMP PUMPS WITHIN THE SUMP PIT. CONNECT TO SANITARY AND VENT AS INDICATED.
AutoCAD SHX Text
7
AutoCAD SHX Text
VENT PIPE AT THE GARAGE ROOF SHALL BE TALLER THAN THE PARAPET.
AutoCAD SHX Text
8
AutoCAD SHX Text
OVERFLOW DRAIN PIPE SHALL BE 75 . REFER TO ARCHITECT DRAWING FOR SECTION.
AutoCAD SHX Text
9
AutoCAD SHX Text
SUPPLY AND INSTALL NEW GREASE INTERCEPTOR BELOW 3 COMPARTMENT SINK. INTERCEPTOR SHALL BE VENTED. INTERCEPTOR SHALL BE SEMI-RECESSED TO THE FLOOR.
AutoCAD SHX Text
M
AutoCAD SHX Text
VEST
AutoCAD SHX Text
001
AutoCAD SHX Text
MECH
AutoCAD SHX Text
003
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
004
AutoCAD SHX Text
CRP OFFICE
AutoCAD SHX Text
015
AutoCAD SHX Text
JC
AutoCAD SHX Text
012
AutoCAD SHX Text
COMMS
AutoCAD SHX Text
011
AutoCAD SHX Text
CIRCULATION
AutoCAD SHX Text
005
AutoCAD SHX Text
REFRIGERATION
AutoCAD SHX Text
002
AutoCAD SHX Text
U-WC
AutoCAD SHX Text
010
AutoCAD SHX Text
WC
AutoCAD SHX Text
009
AutoCAD SHX Text
WC
AutoCAD SHX Text
008
AutoCAD SHX Text
WC
AutoCAD SHX Text
007
AutoCAD SHX Text
WC
AutoCAD SHX Text
006
AutoCAD SHX Text
MULTI-PURPOSE
AutoCAD SHX Text
013
AutoCAD SHX Text
100
AutoCAD SHX Text
HD
AutoCAD SHX Text
FD
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
FFD
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
FD
AutoCAD SHX Text
FD
AutoCAD SHX Text
FD
AutoCAD SHX Text
FD
AutoCAD SHX Text
FD
AutoCAD SHX Text
FD
AutoCAD SHX Text
FD
AutoCAD SHX Text
FD
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
75 PUMPED SANITARY
AutoCAD SHX Text
RD-4
AutoCAD SHX Text
RD-5
AutoCAD SHX Text
RD-3
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
100 DN
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
CTE
AutoCAD SHX Text
EXISTING STORM
AutoCAD SHX Text
100
AutoCAD SHX Text
75
AutoCAD SHX Text
100
AutoCAD SHX Text
75
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
EW
AutoCAD SHX Text
EW
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
75 VENTTHROUGH ROOF
AutoCAD SHX Text
75 VENTTHROUGH ROOF
AutoCAD SHX Text
V
AutoCAD SHX Text
V
AutoCAD SHX Text
V
AutoCAD SHX Text
V
AutoCAD SHX Text
V
AutoCAD SHX Text
V
AutoCAD SHX Text
V
AutoCAD SHX Text
V
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
4
AutoCAD SHX Text
4
AutoCAD SHX Text
4
AutoCAD SHX Text
MATCH LINE
AutoCAD SHX Text
100%%C
AutoCAD SHX Text
150
AutoCAD SHX Text
100
AutoCAD SHX Text
100
AutoCAD SHX Text
100
AutoCAD SHX Text
150
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
DN
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
DRAINAGE PLAN-1
AutoCAD SHX Text
M5.1
AutoCAD SHX Text
PH.: (905) 946 4260 FAX: (905) 946 0901
AutoCAD SHX Text
MARKHAM ONTARIO L3R 1A3
AutoCAD SHX Text
UNIT 229
AutoCAD SHX Text
7181 WOODBINE AVE
AutoCAD SHX Text
%%UTHOMAS A. FEKETE LIMITED
AutoCAD SHX Text
M
AutoCAD SHX Text
VEST
AutoCAD SHX Text
001
AutoCAD SHX Text
MECH
AutoCAD SHX Text
003
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
004
AutoCAD SHX Text
STAFF
AutoCAD SHX Text
018
AutoCAD SHX Text
POS
AutoCAD SHX Text
016
AutoCAD SHX Text
CRP OFFICE
AutoCAD SHX Text
015
AutoCAD SHX Text
JC
AutoCAD SHX Text
012
AutoCAD SHX Text
COMMS
AutoCAD SHX Text
011
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
020
AutoCAD SHX Text
CIRCULATION
AutoCAD SHX Text
005
AutoCAD SHX Text
REFRIGERATION
AutoCAD SHX Text
002
AutoCAD SHX Text
U-WC
AutoCAD SHX Text
010
AutoCAD SHX Text
WC
AutoCAD SHX Text
009
AutoCAD SHX Text
WC
AutoCAD SHX Text
008
AutoCAD SHX Text
WC
AutoCAD SHX Text
007
AutoCAD SHX Text
WC
AutoCAD SHX Text
006
AutoCAD SHX Text
MULTI-PURPOSE
AutoCAD SHX Text
014
AutoCAD SHX Text
MULTI-PURPOSE
AutoCAD SHX Text
013
AutoCAD SHX Text
SKATES
AutoCAD SHX Text
017
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
019
AutoCAD SHX Text
KEY PLAN (NTS)
AutoCAD SHX Text
SCALE : 1:50

PLUMBING CODED NOTES:

9

10

11

12

13

14

15

16

17

18

19

DATE INITIALREVISIONSNo.

DESIGN

DATE:

DRAWNCHECKED

DRAWING NUMBER

SIGNED

SCALE: CONTRACT No.

2019-11-01 ISSUED FOR 60% CONSTRUCTION DOCUMENTS1

WS2492514132

CITY ASSET No. 297

DUFFERIN GROVE PARK NORTH-WEST CORNER

AND CLUBHOUSE IMPROVEMENTS

DR

AW

IN

G P

RIN

T D

AT

E: 7/10/2020 5:09:23 P

M

FIL

EN

AM

E: \\T

AF

_S

ER

VE

R\taf_m

ain

\P

ro

jects\C

urren

t P

ro

jects\18173 D

UF

FE

RIN

G

RO

VE

P

AR

K IM

PR

OV

EM

EN

TS

\300 D

esig

n\301 M

E D

wg

s\18173 M

EC

H\18173

m m

etric.d

wg

YA YA BZ

JOB NUMBER: 18173

2020-01-17 ISSUED FOR 90% COORDINATION2

2020-02-14 PROGRESS SET3

2020-03-06 ISSUED FOR PERMIT4

2020-03-06

2020-03-24 ISSUED FOR CD'S5

2020-06-12

2020-06-12 ISSUED FOR TENDER6

B C D

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

AE

2

C A

4

3

DB

1

DRAINAGE PLAN-21

AutoCAD SHX Text
1
AutoCAD SHX Text
#
AutoCAD SHX Text
PLUMBING AND DRAINAGE GENERAL NOTES
AutoCAD SHX Text
NEW SANITARY LINE SHALL BE PRESSURE TESTED PER LOCAL CODES WITH A MINIMUM REQUIREMENT OF HOLDING 10 FT W.C. FOR 2 (TWO) HOURS.
AutoCAD SHX Text
FURNISH AND INSTALL WATER HAMMER ARRESTORS IN THE DOMESTIC COLD AND HOT WATER PIPING. WATER HAMMER ARRESTORS TO BE LOCATED IN AN ACCESSIBLE LOCATION. UNITS AS MANUFACTURED BY SIOUX OR PRECISION PLUMBING PRODUCTS ARE ACCEPTABLE.
AutoCAD SHX Text
ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOP VALVES TO ISOLATE EACH FIXTURE. REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR FUTURE INFORMATION.
AutoCAD SHX Text
PROVIDE MIXING VALVE, MAX TEMP. SET POINT @ 110°F FOR TEMPEREDWATER AT LAVATORY FOR 1070 ANSI. FIELD VERIFY EXISTING CONDITIONS.
AutoCAD SHX Text
FUR OUT DEMISING WALL FOR PLUMBING FIXTURES INSTALLATION.
AutoCAD SHX Text
PLUMBING CONTRACTOR TO VERIFY ALL CONDITIONS IN THE FIELD PRIOR TO BIDDING WORK. ANY CONDITIONS THAT AFFECT THE INSTALLATION OF THIS PROJECT MUST IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE CONSTRUCTION MANAGER OR BE INCORPORATED IN THE BID.
AutoCAD SHX Text
ALL PIPING WILL BE COPPER OR CAST IRON. ALL PIPING WILL BE PROPERLY HUNG AND SECURED TO AVOID MOVEMENT. DO NOT USE 90° FITTINGS ON TURNS.
AutoCAD SHX Text
SLAB SHALL BE X-RAY SCANNED PRIOR TO CORE DRILLING AND BE FIRE-STOPPED AND WATER-PROOF BY THIS CONTRACTOR. ALLOW FOR AFTER-HOUR X-RAY AND SCANNING FOR ANY CORING/SLAB PENETRATIONS REQUIRED.
AutoCAD SHX Text
WASHROOM FIXTURES TO BE COMMERCIAL GRADE AND ENERGY EFFICIENT (LOW CONSUMPTION MODEL).
AutoCAD SHX Text
PROVIDE ADEQUATE ACCESS TO MAIN DCW ISOLATION VALVE.
AutoCAD SHX Text
COORDINATE ALL UNDER FLOOR PLUMBING WITH LANDLORD AND EXISTING SERVICES BELOW.
AutoCAD SHX Text
3"
AutoCAD SHX Text
SUPPLY AND INSTALL NEW FLUSH VALVE TOILETS. CONNECT 100 SANITARY AND 38 VENTPIPE. (TYPICAL FOR ALL) SUPPLY AND INSTALL NEW LAVATORIES. CONNECT TO 75 SUPPLY AND INSTALL NEW LAVATORIES. CONNECT TO 75 SANITARY AND 32 VENT AS INDICATED ON THE DRAWING. INSTALL FLOOR DRAIN WITHINEACH WASHROOM.
AutoCAD SHX Text
2
AutoCAD SHX Text
SUPPLY AND INSTALL NEW FLOOR DRAINS AS SHOWN ON THE PLAN. CONNECT TO 32 VENT PIPE. TIE INTO MAIN BRANCH AS INDICATED ON THE DRAWING.
AutoCAD SHX Text
3
AutoCAD SHX Text
SUPPLY AND INSTALL SINKS WITHIN THE KITCHEN. VENT AND SANITARY SHALL BE RUN THROUGH CAVITY BEHIND THE COUNTER.
AutoCAD SHX Text
4
AutoCAD SHX Text
SUPPLY AND INSTALL ROOF DRAINS AS INDICATED ON THE DRAWING.
AutoCAD SHX Text
5
AutoCAD SHX Text
SUPPLY AND INSTALL TRENCH DRAIN WITHIN THE ZAMBONI GARAGE. CONNECT TO SANITARY AND VENT AS NEEDED.
AutoCAD SHX Text
6
AutoCAD SHX Text
SUPPLY AND INSTALL SUMP PUMPS WITHIN THE SUMP PIT. CONNECT TO SANITARY AND VENT AS INDICATED.
AutoCAD SHX Text
7
AutoCAD SHX Text
VENT PIPE AT THE GARAGE ROOF SHALL BE TALLER THAN THE PARAPET.
AutoCAD SHX Text
8
AutoCAD SHX Text
OVERFLOW DRAIN PIPE SHALL BE 75 . REFER TO ARCHITECT DRAWING FOR SECTION.
AutoCAD SHX Text
9
AutoCAD SHX Text
SUPPLY AND INSTALL NEW GREASE INTERCEPTOR BELOW 3 COMPARTMENT SINK. INTERCEPTOR SHALL BE VENTED. INTERCEPTOR SHALL BE SEMI-RECESSED TO THE FLOOR.
AutoCAD SHX Text
STAFF
AutoCAD SHX Text
018
AutoCAD SHX Text
POS
AutoCAD SHX Text
016
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
020
AutoCAD SHX Text
MULTI-PURPOSE
AutoCAD SHX Text
014
AutoCAD SHX Text
MULTI-PURPOSE
AutoCAD SHX Text
013
AutoCAD SHX Text
SKATES
AutoCAD SHX Text
017
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
019
AutoCAD SHX Text
EXISTING SANITARY LINE
AutoCAD SHX Text
100
AutoCAD SHX Text
100
AutoCAD SHX Text
DW
AutoCAD SHX Text
HD
AutoCAD SHX Text
FD
AutoCAD SHX Text
FD
AutoCAD SHX Text
FD
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
WF
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
RD-3
AutoCAD SHX Text
RD-2
AutoCAD SHX Text
RD-1
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
75
AutoCAD SHX Text
100
AutoCAD SHX Text
75
AutoCAD SHX Text
100 DN TOLOWER ROOF LEVEL
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
75
AutoCAD SHX Text
EW
AutoCAD SHX Text
38
AutoCAD SHX Text
38
AutoCAD SHX Text
38
AutoCAD SHX Text
V
AutoCAD SHX Text
V
AutoCAD SHX Text
V
AutoCAD SHX Text
V
AutoCAD SHX Text
V
AutoCAD SHX Text
V
AutoCAD SHX Text
V
AutoCAD SHX Text
V
AutoCAD SHX Text
V
AutoCAD SHX Text
V
AutoCAD SHX Text
V
AutoCAD SHX Text
FD
AutoCAD SHX Text
FD
AutoCAD SHX Text
V
AutoCAD SHX Text
V
AutoCAD SHX Text
V
AutoCAD SHX Text
V
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
4
AutoCAD SHX Text
4
AutoCAD SHX Text
MATCH LINE
AutoCAD SHX Text
100%%C
AutoCAD SHX Text
100%%C
AutoCAD SHX Text
100%%C
AutoCAD SHX Text
100%%C
AutoCAD SHX Text
100%%C
AutoCAD SHX Text
100%%C
AutoCAD SHX Text
150
AutoCAD SHX Text
CTE
AutoCAD SHX Text
CTE
AutoCAD SHX Text
CTE
AutoCAD SHX Text
9
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
100
AutoCAD SHX Text
V
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
GI-1
AutoCAD SHX Text
38
AutoCAD SHX Text
DRAINAGE PLAN-2
AutoCAD SHX Text
M5.2
AutoCAD SHX Text
PH.: (905) 946 4260 FAX: (905) 946 0901
AutoCAD SHX Text
MARKHAM ONTARIO L3R 1A3
AutoCAD SHX Text
UNIT 229
AutoCAD SHX Text
7181 WOODBINE AVE
AutoCAD SHX Text
%%UTHOMAS A. FEKETE LIMITED
AutoCAD SHX Text
M
AutoCAD SHX Text
VEST
AutoCAD SHX Text
001
AutoCAD SHX Text
MECH
AutoCAD SHX Text
003
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
004
AutoCAD SHX Text
STAFF
AutoCAD SHX Text
018
AutoCAD SHX Text
POS
AutoCAD SHX Text
016
AutoCAD SHX Text
CRP OFFICE
AutoCAD SHX Text
015
AutoCAD SHX Text
JC
AutoCAD SHX Text
012
AutoCAD SHX Text
COMMS
AutoCAD SHX Text
011
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
020
AutoCAD SHX Text
CIRCULATION
AutoCAD SHX Text
005
AutoCAD SHX Text
REFRIGERATION
AutoCAD SHX Text
002
AutoCAD SHX Text
U-WC
AutoCAD SHX Text
010
AutoCAD SHX Text
WC
AutoCAD SHX Text
009
AutoCAD SHX Text
WC
AutoCAD SHX Text
008
AutoCAD SHX Text
WC
AutoCAD SHX Text
007
AutoCAD SHX Text
WC
AutoCAD SHX Text
006
AutoCAD SHX Text
MULTI-PURPOSE
AutoCAD SHX Text
014
AutoCAD SHX Text
MULTI-PURPOSE
AutoCAD SHX Text
013
AutoCAD SHX Text
SKATES
AutoCAD SHX Text
017
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
019
AutoCAD SHX Text
KEY PLAN (NTS)
AutoCAD SHX Text
SCALE : 1:50

PLUMBING CODED NOTES:

2

C A

4

3

DB

1

DRAINAGE PLAN-31

DATE INITIALREVISIONSNo.

DESIGN

DATE:

DRAWNCHECKED

DRAWING NUMBER

SIGNED

SCALE: CONTRACT No.

2019-11-01 ISSUED FOR 60% CONSTRUCTION DOCUMENTS1

WS2492514132

CITY ASSET No. 297

DUFFERIN GROVE PARK NORTH-WEST CORNER

AND CLUBHOUSE IMPROVEMENTS

DR

AW

IN

G P

RIN

T D

AT

E: 7/10/2020 5:09:33 P

M

FIL

EN

AM

E: \\T

AF

_S

ER

VE

R\taf_m

ain

\P

ro

jects\C

urren

t P

ro

jects\18173 D

UF

FE

RIN

G

RO

VE

P

AR

K IM

PR

OV

EM

EN

TS

\300 D

esig

n\301 M

E D

wg

s\18173 M

EC

H\18173

m m

etric.d

wg

YA YA BZ

JOB NUMBER: 18173

2020-01-17 ISSUED FOR 90% COORDINATION2

2020-02-14 PROGRESS SET3

2020-03-06 ISSUED FOR PERMIT4

2020-03-06

2020-03-24 ISSUED FOR CD'S5

2020-06-12

2020-06-12 ISSUED FOR TENDER6

B C D

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

A

E

2

C A

4

3

DB

1

AutoCAD SHX Text
1
AutoCAD SHX Text
#
AutoCAD SHX Text
PLUMBING AND DRAINAGE GENERAL NOTES
AutoCAD SHX Text
NEW SANITARY LINE SHALL BE PRESSURE TESTED PER LOCAL CODES WITH A MINIMUM REQUIREMENT OF HOLDING 10 FT W.C. FOR 2 (TWO) HOURS.
AutoCAD SHX Text
FURNISH AND INSTALL WATER HAMMER ARRESTORS IN THE DOMESTIC COLD AND HOT WATER PIPING. WATER HAMMER ARRESTORS TO BE LOCATED IN AN ACCESSIBLE LOCATION. UNITS AS MANUFACTURED BY SIOUX OR PRECISION PLUMBING PRODUCTS ARE ACCEPTABLE.
AutoCAD SHX Text
ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOP VALVES TO ISOLATE EACH FIXTURE. REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR FUTURE INFORMATION.
AutoCAD SHX Text
PROVIDE MIXING VALVE, MAX TEMP. SET POINT @ 110°F FOR TEMPEREDWATER AT LAVATORY FOR 1070 ANSI. FIELD VERIFY EXISTING CONDITIONS.
AutoCAD SHX Text
FUR OUT DEMISING WALL FOR PLUMBING FIXTURES INSTALLATION.
AutoCAD SHX Text
PLUMBING CONTRACTOR TO VERIFY ALL CONDITIONS IN THE FIELD PRIOR TO BIDDING WORK. ANY CONDITIONS THAT AFFECT THE INSTALLATION OF THIS PROJECT MUST IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE CONSTRUCTION MANAGER OR BE INCORPORATED IN THE BID.
AutoCAD SHX Text
ALL PIPING WILL BE COPPER OR CAST IRON. ALL PIPING WILL BE PROPERLY HUNG AND SECURED TO AVOID MOVEMENT. DO NOT USE 90° FITTINGS ON TURNS.
AutoCAD SHX Text
SLAB SHALL BE X-RAY SCANNED PRIOR TO CORE DRILLING AND BE FIRE-STOPPED AND WATER-PROOF BY THIS CONTRACTOR. ALLOW FOR AFTER-HOUR X-RAY AND SCANNING FOR ANY CORING/SLAB PENETRATIONS REQUIRED.
AutoCAD SHX Text
WASHROOM FIXTURES TO BE COMMERCIAL GRADE AND ENERGY EFFICIENT (LOW CONSUMPTION MODEL).
AutoCAD SHX Text
PROVIDE ADEQUATE ACCESS TO MAIN DCW ISOLATION VALVE.
AutoCAD SHX Text
COORDINATE ALL UNDER FLOOR PLUMBING WITH LANDLORD AND EXISTING SERVICES BELOW.
AutoCAD SHX Text
3"
AutoCAD SHX Text
SUPPLY AND INSTALL NEW FLUSH VALVE TOILETS. CONNECT 100 SANITARY AND 38 VENTPIPE. (TYPICAL FOR ALL) SUPPLY AND INSTALL NEW LAVATORIES. CONNECT TO 75 SUPPLY AND INSTALL NEW LAVATORIES. CONNECT TO 75 SANITARY AND 32 VENT AS INDICATED ON THE DRAWING. INSTALL FLOOR DRAIN WITHINEACH WASHROOM.
AutoCAD SHX Text
2
AutoCAD SHX Text
SUPPLY AND INSTALL NEW FLOOR DRAINS AS SHOWN ON THE PLAN. CONNECT TO 32 VENT PIPE. TIE INTO MAIN BRANCH AS INDICATED ON THE DRAWING.
AutoCAD SHX Text
3
AutoCAD SHX Text
SUPPLY AND INSTALL SINKS WITHIN THE KITCHEN. VENT AND SANITARY SHALL BE RUN THROUGH CAVITY BEHIND THE COUNTER.
AutoCAD SHX Text
4
AutoCAD SHX Text
SUPPLY AND INSTALL ROOF DRAINS AS INDICATED ON THE DRAWING.
AutoCAD SHX Text
5
AutoCAD SHX Text
SUPPLY AND INSTALL TRENCH DRAIN WITHIN THE ZAMBONI GARAGE. CONNECT TO SANITARY AND VENT AS NEEDED.
AutoCAD SHX Text
6
AutoCAD SHX Text
SUPPLY AND INSTALL SUMP PUMPS WITHIN THE SUMP PIT. CONNECT TO SANITARY AND VENT AS INDICATED.
AutoCAD SHX Text
7
AutoCAD SHX Text
VENT PIPE AT THE GARAGE ROOF SHALL BE TALLER THAN THE PARAPET.
AutoCAD SHX Text
8
AutoCAD SHX Text
OVERFLOW DRAIN PIPE SHALL BE 75 . REFER TO ARCHITECT DRAWING FOR SECTION.
AutoCAD SHX Text
9
AutoCAD SHX Text
SUPPLY AND INSTALL NEW GREASE INTERCEPTOR BELOW 3 COMPARTMENT SINK. INTERCEPTOR SHALL BE VENTED. INTERCEPTOR SHALL BE SEMI-RECESSED TO THE FLOOR.
AutoCAD SHX Text
EW
AutoCAD SHX Text
FD
AutoCAD SHX Text
FD
AutoCAD SHX Text
FFD
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
SP-1
AutoCAD SHX Text
SP-2
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
75
AutoCAD SHX Text
75
AutoCAD SHX Text
75
AutoCAD SHX Text
100
AutoCAD SHX Text
100
AutoCAD SHX Text
TD-1
AutoCAD SHX Text
75 VENT
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
75 PUMPED SANITARY
AutoCAD SHX Text
SCALE : 1:50
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
SP CONTROL PANEL
AutoCAD SHX Text
DRAINAGE PLAN-3
AutoCAD SHX Text
M5.3
AutoCAD SHX Text
PH.: (905) 946 4260 FAX: (905) 946 0901
AutoCAD SHX Text
MARKHAM ONTARIO L3R 1A3
AutoCAD SHX Text
UNIT 229
AutoCAD SHX Text
7181 WOODBINE AVE
AutoCAD SHX Text
%%UTHOMAS A. FEKETE LIMITED
AutoCAD SHX Text
M
AutoCAD SHX Text
VEST
AutoCAD SHX Text
001
AutoCAD SHX Text
MECH
AutoCAD SHX Text
003
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
004
AutoCAD SHX Text
STAFF
AutoCAD SHX Text
018
AutoCAD SHX Text
POS
AutoCAD SHX Text
016
AutoCAD SHX Text
CRP OFFICE
AutoCAD SHX Text
015
AutoCAD SHX Text
JC
AutoCAD SHX Text
012
AutoCAD SHX Text
COMMS
AutoCAD SHX Text
011
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
020
AutoCAD SHX Text
CIRCULATION
AutoCAD SHX Text
005
AutoCAD SHX Text
REFRIGERATION
AutoCAD SHX Text
002
AutoCAD SHX Text
U-WC
AutoCAD SHX Text
010
AutoCAD SHX Text
WC
AutoCAD SHX Text
009
AutoCAD SHX Text
WC
AutoCAD SHX Text
008
AutoCAD SHX Text
WC
AutoCAD SHX Text
007
AutoCAD SHX Text
WC
AutoCAD SHX Text
006
AutoCAD SHX Text
MULTI-PURPOSE
AutoCAD SHX Text
014
AutoCAD SHX Text
MULTI-PURPOSE
AutoCAD SHX Text
013
AutoCAD SHX Text
SKATES
AutoCAD SHX Text
017
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
019
AutoCAD SHX Text
KEY PLAN (NTS)

HOT WATER HEATER SCHEDULE

FAN SCHEDULE (NEW)

ROOF TOP UNIT SCHEDULE (NEW)

SUMP PUMP SCHEDULE

HEATER SCHEDULE

SCHEDULE OF GRILLES AND DIFFUSERS (E.H. PRICE)

MAKE-UP AIR UNIT SCHEDULE (NEW)

GREASE INTERCEPTOR SCHEDULE

DATE INITIALREVISIONSNo.

DESIGN

DATE:

DRAWNCHECKED

DRAWING NUMBER

SIGNED

SCALE: CONTRACT No.

2019-11-01 ISSUED FOR 60% CONSTRUCTION DOCUMENTS1

WS2492514132

CITY ASSET No. 297

DUFFERIN GROVE PARK NORTH-WEST CORNER

AND CLUBHOUSE IMPROVEMENTS

DR

AW

IN

G P

RIN

T D

AT

E: 7/10/2020 5:04:18 P

M

FIL

EN

AM

E: \\T

AF

_S

ER

VE

R\taf_m

ain

\P

ro

jects\C

urren

t P

ro

jects\18173 D

UF

FE

RIN

G

RO

VE

P

AR

K IM

PR

OV

EM

EN

TS

\300 D

esig

n\301 M

E D

wg

s\18173 M

EC

H\18173

m m

etric.d

wg

YA YA BZ

JOB NUMBER: 18173

2020-01-17 ISSUED FOR 90% COORDINATION2

2020-02-14 PROGRESS SET3

2020-03-06 ISSUED FOR PERMIT4

2020-03-06

2020-03-24 ISSUED FOR CD'S5

2020-06-12

2020-06-12 ISSUED FOR TENDER6

AutoCAD SHX Text
378L CAPACITY, 19 GAS CONNECTION, TERMINATE T & P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY CAPACITY, 19 GAS CONNECTION, TERMINATE T & P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY CAPACITY, 19 GAS CONNECTION, TERMINATE T & P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY 19 GAS CONNECTION, TERMINATE T & P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY 19 GAS CONNECTION, TERMINATE T & P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY GAS CONNECTION, TERMINATE T & P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY CONNECTION, TERMINATE T & P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY CONNECTION, TERMINATE T & P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY TERMINATE T & P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY TERMINATE T & P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY T & P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY T & P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY & P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY & P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY OVER FUNNEL FLOOR DRAIN. POWER WIRING BY OVER FUNNEL FLOOR DRAIN. POWER WIRING BY FUNNEL FLOOR DRAIN. POWER WIRING BY FUNNEL FLOOR DRAIN. POWER WIRING BY FLOOR DRAIN. POWER WIRING BY FLOOR DRAIN. POWER WIRING BY DRAIN. POWER WIRING BY DRAIN. POWER WIRING BY POWER WIRING BY POWER WIRING BY WIRING BY WIRING BY BY BY ELECTRICAL CONTRACTOR. MAXIMUM SETTING SHALL BE 49 DEG.C. SHIPPING WEIGHT IS 252KG.
AutoCAD SHX Text
HWT-1
AutoCAD SHX Text
GAS HOT WATER TANK
AutoCAD SHX Text
A.O. SMITH/BTH-199
AutoCAD SHX Text
TAG
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
MOTOR
AutoCAD SHX Text
HZ
AutoCAD SHX Text
VOLT
AutoCAD SHX Text
PH
AutoCAD SHX Text
L/S
AutoCAD SHX Text
ESP
AutoCAD SHX Text
WATTS
AutoCAD SHX Text
RPM
AutoCAD SHX Text
NOTES: 1. COORDINATE ELECTRICAL CONNECTION OF EXHAUST FAN WITH ELECTRICAL DIVISION. COORDINATE ELECTRICAL CONNECTION OF EXHAUST FAN WITH ELECTRICAL DIVISION. COORDINATE ELECTRICAL CONNECTION OF EXHAUST FAN WITH ELECTRICAL DIVISION. 2. THE FAN (EF-2) SHALL BE COMPLETE WITH COOLING THERMOSTAT. WHEN THE ROOM TEMPERATURE REACH 29°C, THE FAN WILL BE TURNED ON. WHEN THE ROOM THE FAN (EF-2) SHALL BE COMPLETE WITH COOLING THERMOSTAT. WHEN THE ROOM TEMPERATURE REACH 29°C, THE FAN WILL BE TURNED ON. WHEN THE ROOM THE FAN (EF-2) SHALL BE COMPLETE WITH COOLING THERMOSTAT. WHEN THE ROOM TEMPERATURE REACH 29°C, THE FAN WILL BE TURNED ON. WHEN THE ROOM TEMPERATURE DROPPED DOWN TO 22.2°C, THE FAN WILL BE TURNED OFF. 3. THE FAN (EF-3) SERVES THE REFRIGERANT ROOM. COMPLETE WITH VERI-GREEN TWO-SPEED MOTOR AND CONTROL PANEL. REFER TO REFRIGERANT ROOM SUPPLY AIR DETAIL FOR SEQUENCE OF OPERATION (M8.2).
AutoCAD SHX Text
PA
AutoCAD SHX Text
AMP
AutoCAD SHX Text
MAKE/MODEL
AutoCAD SHX Text
WEIGHT
AutoCAD SHX Text
(KG)
AutoCAD SHX Text
EF-1
AutoCAD SHX Text
EXHAUST FAN
AutoCAD SHX Text
CAPTIVEAIRE/DU85HFA
AutoCAD SHX Text
208
AutoCAD SHX Text
578
AutoCAD SHX Text
249
AutoCAD SHX Text
-
AutoCAD SHX Text
1199
AutoCAD SHX Text
9.8
AutoCAD SHX Text
60
AutoCAD SHX Text
1
AutoCAD SHX Text
44
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
EF-2
AutoCAD SHX Text
EXHAUST FAN
AutoCAD SHX Text
GREENHECK/G070HP-A
AutoCAD SHX Text
120
AutoCAD SHX Text
189
AutoCAD SHX Text
124
AutoCAD SHX Text
-
AutoCAD SHX Text
1725
AutoCAD SHX Text
-
AutoCAD SHX Text
60
AutoCAD SHX Text
1
AutoCAD SHX Text
6.8
AutoCAD SHX Text
7.5
AutoCAD SHX Text
TONS
AutoCAD SHX Text
RTU-1
AutoCAD SHX Text
REF.
AutoCAD SHX Text
UNIT
AutoCAD SHX Text
COOLING CAPACITY (KW)
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
MODEL No.
AutoCAD SHX Text
SENS.
AutoCAD SHX Text
TOTAL
AutoCAD SHX Text
HEATING CAPACITY (KW)
AutoCAD SHX Text
ECON.
AutoCAD SHX Text
INPUT
AutoCAD SHX Text
OUTPUT
AutoCAD SHX Text
L/S
AutoCAD SHX Text
TSP(PA)
AutoCAD SHX Text
FAN
AutoCAD SHX Text
MIN.
AutoCAD SHX Text
F/A
AutoCAD SHX Text
(L/S)
AutoCAD SHX Text
POWER
AutoCAD SHX Text
(KG)
AutoCAD SHX Text
WEIGHT
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
26.0
AutoCAD SHX Text
25.0
AutoCAD SHX Text
1415
AutoCAD SHX Text
213
AutoCAD SHX Text
575/3%%C/60
AutoCAD SHX Text
LENNOX/ LGH092H4B
AutoCAD SHX Text
34.3
AutoCAD SHX Text
42.2
AutoCAD SHX Text
375
AutoCAD SHX Text
562
AutoCAD SHX Text
YES
AutoCAD SHX Text
EER
AutoCAD SHX Text
12.5
AutoCAD SHX Text
HP
AutoCAD SHX Text
3
AutoCAD SHX Text
NOTES: 1. ENERGY RECOVERY UNIT, FACTORY INSTALLED ECONOMIZER (DRYBULB). ENERGY RECOVERY UNIT, FACTORY INSTALLED ECONOMIZER (DRYBULB). 2. FACTORY INSTALLED UNFUSED DISCONNECT SWITCH. FACTORY INSTALLED UNFUSED DISCONNECT SWITCH. 3. 350MM HIGH ROOF MOUNTING CURB. 350MM HIGH ROOF MOUNTING CURB. 4. R-410A REFRIGERANT. R-410A REFRIGERANT. 5. PREMIUM EFFICIENCY SUPPLY FAN MOTORS. PREMIUM EFFICIENCY SUPPLY FAN MOTORS. 6. FACTORY INSTALLED HUMIDITROL, DEHUMIDIFICATION SYSTEM. FACTORY INSTALLED HUMIDITROL, DEHUMIDIFICATION SYSTEM. 7. FACTORY INSTALLED REFRIGERANT SERVICE VALVES, INCLUDING A CHARGING VALVE. FACTORY INSTALLED REFRIGERANT SERVICE VALVES, INCLUDING A CHARGING VALVE. 8. FACTORY INSTALLED COIL GUARDS. FACTORY INSTALLED COIL GUARDS. 9. A HONEYWELL COMMERCIAL VISION PRO 8000 TOUCH SCREEN PROGRAMMABLE ELECTRONIC THERMOSTAT WITH MULTIPLE LOLCKOUT LEVEL, CONFIGURABLE RECOVERY RAMPS, HOLIDAY A HONEYWELL COMMERCIAL VISION PRO 8000 TOUCH SCREEN PROGRAMMABLE ELECTRONIC THERMOSTAT WITH MULTIPLE LOLCKOUT LEVEL, CONFIGURABLE RECOVERY RAMPS, HOLIDAY SERBACK, AND A HONEYWELL #C7189U1005 WHITE BLANK FACE REMOTE SENSOR WITH A MINIMUM OF 30 M OF COILED PLENUM RATED CABLE PER UNIT. 10. MICROPROCESSOR BASED CONTROLS. MICROPROCESSOR BASED CONTROLS. 11. HINGED/GASKETED ACCESS PANELS.HINGED/GASKETED ACCESS PANELS.
AutoCAD SHX Text
ALL ROOF HVAC EQUIPMENT SHALL HAVE THE FOLLOWING OPTIONS: 1. THE UNIT SHALL BE C/W 2 SET OF FILTERS. ONE SET OF FILTER SHOULD BE INSTALLED DURING THE CONSTRUCTION. ANOTHER SET SHOULD BE THE UNIT SHALL BE C/W 2 SET OF FILTERS. ONE SET OF FILTER SHOULD BE INSTALLED DURING THE CONSTRUCTION. ANOTHER SET SHOULD BE INSTALLED UPON COMPLETION. 2. BALANCE RTU TO TOTAL AND OUTDOOR AIR AMOUNT SHOWN. BALANCE RTU TO TOTAL AND OUTDOOR AIR AMOUNT SHOWN. 3. THIS CONTRACTOR SHALL CHECK WHETHER OR NOT ROOF CURBS IS REQUIRED OR THE UNIT IS IN STRUCTURAL FRAMES.THIS CONTRACTOR SHALL CHECK WHETHER OR NOT ROOF CURBS IS REQUIRED OR THE UNIT IS IN STRUCTURAL FRAMES.
AutoCAD SHX Text
378L CAPACITY, 19 GAS CONNECTION, TERMINATE T & P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY CAPACITY, 19 GAS CONNECTION, TERMINATE T & P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY CAPACITY, 19 GAS CONNECTION, TERMINATE T & P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY 19 GAS CONNECTION, TERMINATE T & P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY 19 GAS CONNECTION, TERMINATE T & P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY GAS CONNECTION, TERMINATE T & P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY CONNECTION, TERMINATE T & P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY CONNECTION, TERMINATE T & P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY TERMINATE T & P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY TERMINATE T & P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY T & P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY T & P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY & P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY & P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY P RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY RELIEF VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY VALVE WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY WITH OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY OPEN SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY SIGHT OVER FUNNEL FLOOR DRAIN. POWER WIRING BY OVER FUNNEL FLOOR DRAIN. POWER WIRING BY OVER FUNNEL FLOOR DRAIN. POWER WIRING BY FUNNEL FLOOR DRAIN. POWER WIRING BY FUNNEL FLOOR DRAIN. POWER WIRING BY FLOOR DRAIN. POWER WIRING BY FLOOR DRAIN. POWER WIRING BY DRAIN. POWER WIRING BY DRAIN. POWER WIRING BY POWER WIRING BY POWER WIRING BY WIRING BY WIRING BY BY BY ELECTRICAL CONTRACTOR. MAXIMUM SETTING SHALL BE 49 DEG.C. SHIPPING WEIGHT IS 252KG.
AutoCAD SHX Text
HWT-2
AutoCAD SHX Text
GAS HOT WATER TANK
AutoCAD SHX Text
A.O. SMITH/BTH-199
AutoCAD SHX Text
SP-1&2
AutoCAD SHX Text
SUMP PUMP
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
SYSTEM
AutoCAD SHX Text
MODEL NO.
AutoCAD SHX Text
LPS
AutoCAD SHX Text
HEAD
AutoCAD SHX Text
H.P.
AutoCAD SHX Text
VOLTAGE
AutoCAD SHX Text
SOLID HANDLING
AutoCAD SHX Text
DUPLEX SUMP PUMP
AutoCAD SHX Text
SULZER/EF-05W
AutoCAD SHX Text
2.65
AutoCAD SHX Text
3.66
AutoCAD SHX Text
0.5
AutoCAD SHX Text
208V/1
AutoCAD SHX Text
DISCHARGE
AutoCAD SHX Text
50MM
AutoCAD SHX Text
VORTEX IMPELLER
AutoCAD SHX Text
UDAP-45
AutoCAD SHX Text
REZNOR
AutoCAD SHX Text
TAG
AutoCAD SHX Text
WATTS
AutoCAD SHX Text
MFGR.
AutoCAD SHX Text
MODEL
AutoCAD SHX Text
L/S
AutoCAD SHX Text
INPUT
AutoCAD SHX Text
OUTPUT
AutoCAD SHX Text
MOTOR
AutoCAD SHX Text
HP
AutoCAD SHX Text
MOCP
AutoCAD SHX Text
UH-1
AutoCAD SHX Text
FLA
AutoCAD SHX Text
EF-3
AutoCAD SHX Text
EXHAUST FAN
AutoCAD SHX Text
GREENHECK/GB161
AutoCAD SHX Text
1086
AutoCAD SHX Text
EF-4
AutoCAD SHX Text
EXHAUST FAN
AutoCAD SHX Text
GREENHECK/G080HP-D
AutoCAD SHX Text
120
AutoCAD SHX Text
210
AutoCAD SHX Text
24.9
AutoCAD SHX Text
-
AutoCAD SHX Text
1550
AutoCAD SHX Text
-
AutoCAD SHX Text
60
AutoCAD SHX Text
1
AutoCAD SHX Text
REFER TO CAPTIVEAIRE DRAWINGS FOR MORE INFORMATION
AutoCAD SHX Text
REFER TO NOTE BELOW
AutoCAD SHX Text
HP-1/20
AutoCAD SHX Text
155
AutoCAD SHX Text
-
AutoCAD SHX Text
1660
AutoCAD SHX Text
40
AutoCAD SHX Text
A
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
MODEL NO.
AutoCAD SHX Text
VOLUME DAMPER
AutoCAD SHX Text
PRE-FINISH & REMARKS
AutoCAD SHX Text
NOTES: 1. ALL S/A DIFFUSERS AT DRYWALL CEILING SHALL BE C/W VOLUME DAMPERS COLOUR OF ALL DIFFUSERS AND GRILLES SHALL MATCH COLOUR OF T-BAR OR DRYWALL ALL S/A DIFFUSERS AT DRYWALL CEILING SHALL BE C/W VOLUME DAMPERS COLOUR OF ALL DIFFUSERS AND GRILLES SHALL MATCH COLOUR OF T-BAR OR DRYWALL CEILING BAKED ON SHOP FINISHED WHERE INSTALLED. 2. ALL LINEAR DIFFUSERS SHALL BE C/W ALL REQUIRED ACCESSORIES SUCH AS ALIGNMENT STRIPS, PLASTER FRAME SPACERS. ALL LINEAR DIFFUSERS SHALL BE C/W ALL REQUIRED ACCESSORIES SUCH AS ALIGNMENT STRIPS, PLASTER FRAME SPACERS. 3. ALL LINEAR RETURN AIR DIFFUSER SHALL HAVE BLADES REMOVE FROM DIFFUSER SLOTS TO OPEN UP RETURN AIR PASSAGE. ALL LINEAR RETURN AIR DIFFUSER SHALL HAVE BLADES REMOVE FROM DIFFUSER SLOTS TO OPEN UP RETURN AIR PASSAGE. 4. REFER TO & COORDINATE WITH ARCHITECTURAL REFLECTED CEILING PLANS TO DETERMINE THE TYPE OF MOUNTING REQUIRED FOR EACH TYPE OF DIFFUSERS. REFER TO & COORDINATE WITH ARCHITECTURAL REFLECTED CEILING PLANS TO DETERMINE THE TYPE OF MOUNTING REQUIRED FOR EACH TYPE OF DIFFUSERS. 5. APPROVED EQUALS ARE ACCEPTABLE.APPROVED EQUALS ARE ACCEPTABLE.
AutoCAD SHX Text
12" x 12" (305 x 302 MM) NOMINAL FACE, FRAME STYLE TO SUIT CEILING TYPE, COMPLETE WITH RADIAL OPPOSED BLADE x 12" (305 x 302 MM) NOMINAL FACE, FRAME STYLE TO SUIT CEILING TYPE, COMPLETE WITH RADIAL OPPOSED BLADE x 12" (305 x 302 MM) NOMINAL FACE, FRAME STYLE TO SUIT CEILING TYPE, COMPLETE WITH RADIAL OPPOSED BLADE 12" (305 x 302 MM) NOMINAL FACE, FRAME STYLE TO SUIT CEILING TYPE, COMPLETE WITH RADIAL OPPOSED BLADE 12" (305 x 302 MM) NOMINAL FACE, FRAME STYLE TO SUIT CEILING TYPE, COMPLETE WITH RADIAL OPPOSED BLADE (305 x 302 MM) NOMINAL FACE, FRAME STYLE TO SUIT CEILING TYPE, COMPLETE WITH RADIAL OPPOSED BLADE (305 x 302 MM) NOMINAL FACE, FRAME STYLE TO SUIT CEILING TYPE, COMPLETE WITH RADIAL OPPOSED BLADE x 302 MM) NOMINAL FACE, FRAME STYLE TO SUIT CEILING TYPE, COMPLETE WITH RADIAL OPPOSED BLADE x 302 MM) NOMINAL FACE, FRAME STYLE TO SUIT CEILING TYPE, COMPLETE WITH RADIAL OPPOSED BLADE 302 MM) NOMINAL FACE, FRAME STYLE TO SUIT CEILING TYPE, COMPLETE WITH RADIAL OPPOSED BLADE 302 MM) NOMINAL FACE, FRAME STYLE TO SUIT CEILING TYPE, COMPLETE WITH RADIAL OPPOSED BLADE MM) NOMINAL FACE, FRAME STYLE TO SUIT CEILING TYPE, COMPLETE WITH RADIAL OPPOSED BLADE MM) NOMINAL FACE, FRAME STYLE TO SUIT CEILING TYPE, COMPLETE WITH RADIAL OPPOSED BLADE NOMINAL FACE, FRAME STYLE TO SUIT CEILING TYPE, COMPLETE WITH RADIAL OPPOSED BLADE NOMINAL FACE, FRAME STYLE TO SUIT CEILING TYPE, COMPLETE WITH RADIAL OPPOSED BLADE FACE, FRAME STYLE TO SUIT CEILING TYPE, COMPLETE WITH RADIAL OPPOSED BLADE FACE, FRAME STYLE TO SUIT CEILING TYPE, COMPLETE WITH RADIAL OPPOSED BLADE FRAME STYLE TO SUIT CEILING TYPE, COMPLETE WITH RADIAL OPPOSED BLADE FRAME STYLE TO SUIT CEILING TYPE, COMPLETE WITH RADIAL OPPOSED BLADE STYLE TO SUIT CEILING TYPE, COMPLETE WITH RADIAL OPPOSED BLADE STYLE TO SUIT CEILING TYPE, COMPLETE WITH RADIAL OPPOSED BLADE TO SUIT CEILING TYPE, COMPLETE WITH RADIAL OPPOSED BLADE TO SUIT CEILING TYPE, COMPLETE WITH RADIAL OPPOSED BLADE SUIT CEILING TYPE, COMPLETE WITH RADIAL OPPOSED BLADE SUIT CEILING TYPE, COMPLETE WITH RADIAL OPPOSED BLADE CEILING TYPE, COMPLETE WITH RADIAL OPPOSED BLADE CEILING TYPE, COMPLETE WITH RADIAL OPPOSED BLADE TYPE, COMPLETE WITH RADIAL OPPOSED BLADE TYPE, COMPLETE WITH RADIAL OPPOSED BLADE COMPLETE WITH RADIAL OPPOSED BLADE COMPLETE WITH RADIAL OPPOSED BLADE WITH RADIAL OPPOSED BLADE WITH RADIAL OPPOSED BLADE RADIAL OPPOSED BLADE RADIAL OPPOSED BLADE OPPOSED BLADE OPPOSED BLADE BLADE BLADE DAMPER, FINISH OFF WHITE BAKED ENAMEL, COLOR TO BE SELECTED BY ARCHITECT.
AutoCAD SHX Text
S/A SQUARE PLAQUE DIFFUSER
AutoCAD SHX Text
SPD/B12
AutoCAD SHX Text
B
AutoCAD SHX Text
LINEAR SUPPLY AIR DIFFUSER
AutoCAD SHX Text
SDS150
AutoCAD SHX Text
LENGTH AS INDICATED ON DRAWING, 2 SLOT WITH 1-1/2" SLOT C/W PLENUM AND 8EC DAMPER. FRAME STYLE TO SUIT AS INDICATED ON DRAWING, 2 SLOT WITH 1-1/2" SLOT C/W PLENUM AND 8EC DAMPER. FRAME STYLE TO SUIT AS INDICATED ON DRAWING, 2 SLOT WITH 1-1/2" SLOT C/W PLENUM AND 8EC DAMPER. FRAME STYLE TO SUIT INDICATED ON DRAWING, 2 SLOT WITH 1-1/2" SLOT C/W PLENUM AND 8EC DAMPER. FRAME STYLE TO SUIT INDICATED ON DRAWING, 2 SLOT WITH 1-1/2" SLOT C/W PLENUM AND 8EC DAMPER. FRAME STYLE TO SUIT ON DRAWING, 2 SLOT WITH 1-1/2" SLOT C/W PLENUM AND 8EC DAMPER. FRAME STYLE TO SUIT ON DRAWING, 2 SLOT WITH 1-1/2" SLOT C/W PLENUM AND 8EC DAMPER. FRAME STYLE TO SUIT DRAWING, 2 SLOT WITH 1-1/2" SLOT C/W PLENUM AND 8EC DAMPER. FRAME STYLE TO SUIT DRAWING, 2 SLOT WITH 1-1/2" SLOT C/W PLENUM AND 8EC DAMPER. FRAME STYLE TO SUIT 2 SLOT WITH 1-1/2" SLOT C/W PLENUM AND 8EC DAMPER. FRAME STYLE TO SUIT 2 SLOT WITH 1-1/2" SLOT C/W PLENUM AND 8EC DAMPER. FRAME STYLE TO SUIT SLOT WITH 1-1/2" SLOT C/W PLENUM AND 8EC DAMPER. FRAME STYLE TO SUIT SLOT WITH 1-1/2" SLOT C/W PLENUM AND 8EC DAMPER. FRAME STYLE TO SUIT WITH 1-1/2" SLOT C/W PLENUM AND 8EC DAMPER. FRAME STYLE TO SUIT WITH 1-1/2" SLOT C/W PLENUM AND 8EC DAMPER. FRAME STYLE TO SUIT 1-1/2" SLOT C/W PLENUM AND 8EC DAMPER. FRAME STYLE TO SUIT 1-1/2" SLOT C/W PLENUM AND 8EC DAMPER. FRAME STYLE TO SUIT SLOT C/W PLENUM AND 8EC DAMPER. FRAME STYLE TO SUIT SLOT C/W PLENUM AND 8EC DAMPER. FRAME STYLE TO SUIT C/W PLENUM AND 8EC DAMPER. FRAME STYLE TO SUIT C/W PLENUM AND 8EC DAMPER. FRAME STYLE TO SUIT PLENUM AND 8EC DAMPER. FRAME STYLE TO SUIT PLENUM AND 8EC DAMPER. FRAME STYLE TO SUIT AND 8EC DAMPER. FRAME STYLE TO SUIT AND 8EC DAMPER. FRAME STYLE TO SUIT 8EC DAMPER. FRAME STYLE TO SUIT 8EC DAMPER. FRAME STYLE TO SUIT DAMPER. FRAME STYLE TO SUIT DAMPER. FRAME STYLE TO SUIT FRAME STYLE TO SUIT FRAME STYLE TO SUIT STYLE TO SUIT STYLE TO SUIT TO SUIT TO SUIT SUIT SUIT CEILING TYPE, FINISH OFF WHITE BAKED ENAMEL, COLOR TO BE SELECTED BY ARCHITECT.
AutoCAD SHX Text
RETURN AIR GRILLE
AutoCAD SHX Text
80 SERIES/B12
AutoCAD SHX Text
NO
AutoCAD SHX Text
80/TB/B12 (FOR T-BAR), OR 80/C/K/C/B12 (FOR DRYWALL) 1/2" x 1/2" x 1/2" (13 x 13 x 13mm) ALUMINUM EGG (FOR T-BAR), OR 80/C/K/C/B12 (FOR DRYWALL) 1/2" x 1/2" x 1/2" (13 x 13 x 13mm) ALUMINUM EGG (FOR T-BAR), OR 80/C/K/C/B12 (FOR DRYWALL) 1/2" x 1/2" x 1/2" (13 x 13 x 13mm) ALUMINUM EGG T-BAR), OR 80/C/K/C/B12 (FOR DRYWALL) 1/2" x 1/2" x 1/2" (13 x 13 x 13mm) ALUMINUM EGG T-BAR), OR 80/C/K/C/B12 (FOR DRYWALL) 1/2" x 1/2" x 1/2" (13 x 13 x 13mm) ALUMINUM EGG OR 80/C/K/C/B12 (FOR DRYWALL) 1/2" x 1/2" x 1/2" (13 x 13 x 13mm) ALUMINUM EGG OR 80/C/K/C/B12 (FOR DRYWALL) 1/2" x 1/2" x 1/2" (13 x 13 x 13mm) ALUMINUM EGG 80/C/K/C/B12 (FOR DRYWALL) 1/2" x 1/2" x 1/2" (13 x 13 x 13mm) ALUMINUM EGG 80/C/K/C/B12 (FOR DRYWALL) 1/2" x 1/2" x 1/2" (13 x 13 x 13mm) ALUMINUM EGG (FOR DRYWALL) 1/2" x 1/2" x 1/2" (13 x 13 x 13mm) ALUMINUM EGG (FOR DRYWALL) 1/2" x 1/2" x 1/2" (13 x 13 x 13mm) ALUMINUM EGG DRYWALL) 1/2" x 1/2" x 1/2" (13 x 13 x 13mm) ALUMINUM EGG DRYWALL) 1/2" x 1/2" x 1/2" (13 x 13 x 13mm) ALUMINUM EGG 1/2" x 1/2" x 1/2" (13 x 13 x 13mm) ALUMINUM EGG 1/2" x 1/2" x 1/2" (13 x 13 x 13mm) ALUMINUM EGG x 1/2" x 1/2" (13 x 13 x 13mm) ALUMINUM EGG x 1/2" x 1/2" (13 x 13 x 13mm) ALUMINUM EGG 1/2" x 1/2" (13 x 13 x 13mm) ALUMINUM EGG 1/2" x 1/2" (13 x 13 x 13mm) ALUMINUM EGG x 1/2" (13 x 13 x 13mm) ALUMINUM EGG x 1/2" (13 x 13 x 13mm) ALUMINUM EGG 1/2" (13 x 13 x 13mm) ALUMINUM EGG 1/2" (13 x 13 x 13mm) ALUMINUM EGG (13 x 13 x 13mm) ALUMINUM EGG (13 x 13 x 13mm) ALUMINUM EGG x 13 x 13mm) ALUMINUM EGG x 13 x 13mm) ALUMINUM EGG 13 x 13mm) ALUMINUM EGG 13 x 13mm) ALUMINUM EGG x 13mm) ALUMINUM EGG x 13mm) ALUMINUM EGG 13mm) ALUMINUM EGG 13mm) ALUMINUM EGG ALUMINUM EGG ALUMINUM EGG EGG EGG CRATE, COLOR TO BE SELECTED BY ARCHITECT.
AutoCAD SHX Text
ROUND PLAQUE DIFFUSER
AutoCAD SHX Text
RPD/B12
AutoCAD SHX Text
ADJUSTABLE AND VOLUME CONTROL. FINISH OFF WHITE BAKED ENAMEL, SUITABLE FOR WALL OR DRYWALL CEILING, COLOR AND VOLUME CONTROL. FINISH OFF WHITE BAKED ENAMEL, SUITABLE FOR WALL OR DRYWALL CEILING, COLOR AND VOLUME CONTROL. FINISH OFF WHITE BAKED ENAMEL, SUITABLE FOR WALL OR DRYWALL CEILING, COLOR VOLUME CONTROL. FINISH OFF WHITE BAKED ENAMEL, SUITABLE FOR WALL OR DRYWALL CEILING, COLOR VOLUME CONTROL. FINISH OFF WHITE BAKED ENAMEL, SUITABLE FOR WALL OR DRYWALL CEILING, COLOR CONTROL. FINISH OFF WHITE BAKED ENAMEL, SUITABLE FOR WALL OR DRYWALL CEILING, COLOR CONTROL. FINISH OFF WHITE BAKED ENAMEL, SUITABLE FOR WALL OR DRYWALL CEILING, COLOR FINISH OFF WHITE BAKED ENAMEL, SUITABLE FOR WALL OR DRYWALL CEILING, COLOR FINISH OFF WHITE BAKED ENAMEL, SUITABLE FOR WALL OR DRYWALL CEILING, COLOR OFF WHITE BAKED ENAMEL, SUITABLE FOR WALL OR DRYWALL CEILING, COLOR OFF WHITE BAKED ENAMEL, SUITABLE FOR WALL OR DRYWALL CEILING, COLOR WHITE BAKED ENAMEL, SUITABLE FOR WALL OR DRYWALL CEILING, COLOR WHITE BAKED ENAMEL, SUITABLE FOR WALL OR DRYWALL CEILING, COLOR BAKED ENAMEL, SUITABLE FOR WALL OR DRYWALL CEILING, COLOR BAKED ENAMEL, SUITABLE FOR WALL OR DRYWALL CEILING, COLOR ENAMEL, SUITABLE FOR WALL OR DRYWALL CEILING, COLOR ENAMEL, SUITABLE FOR WALL OR DRYWALL CEILING, COLOR SUITABLE FOR WALL OR DRYWALL CEILING, COLOR SUITABLE FOR WALL OR DRYWALL CEILING, COLOR FOR WALL OR DRYWALL CEILING, COLOR FOR WALL OR DRYWALL CEILING, COLOR WALL OR DRYWALL CEILING, COLOR WALL OR DRYWALL CEILING, COLOR OR DRYWALL CEILING, COLOR OR DRYWALL CEILING, COLOR DRYWALL CEILING, COLOR DRYWALL CEILING, COLOR CEILING, COLOR CEILING, COLOR COLOR COLOR TO BE SELECTED BY ARCHITECT. MOUNT AT LIGHT FIXTURE HEIGHT.
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
YES
AutoCAD SHX Text
YES
AutoCAD SHX Text
YES
AutoCAD SHX Text
535 SERIES
AutoCAD SHX Text
RETURN GRILLE WITH 45 DEFLECTION AND 1/2" BLADE SPACING. DEFLECTION DOWNWARD. FINISH TO BE GRILLE WITH 45 DEFLECTION AND 1/2" BLADE SPACING. DEFLECTION DOWNWARD. FINISH TO BE GRILLE WITH 45 DEFLECTION AND 1/2" BLADE SPACING. DEFLECTION DOWNWARD. FINISH TO BE WITH 45 DEFLECTION AND 1/2" BLADE SPACING. DEFLECTION DOWNWARD. FINISH TO BE WITH 45 DEFLECTION AND 1/2" BLADE SPACING. DEFLECTION DOWNWARD. FINISH TO BE 45 DEFLECTION AND 1/2" BLADE SPACING. DEFLECTION DOWNWARD. FINISH TO BE 45° DEFLECTION AND 1/2" BLADE SPACING. DEFLECTION DOWNWARD. FINISH TO BE DEFLECTION AND 1/2" BLADE SPACING. DEFLECTION DOWNWARD. FINISH TO BE AND 1/2" BLADE SPACING. DEFLECTION DOWNWARD. FINISH TO BE AND 1/2" BLADE SPACING. DEFLECTION DOWNWARD. FINISH TO BE 1/2" BLADE SPACING. DEFLECTION DOWNWARD. FINISH TO BE 1/2" BLADE SPACING. DEFLECTION DOWNWARD. FINISH TO BE BLADE SPACING. DEFLECTION DOWNWARD. FINISH TO BE BLADE SPACING. DEFLECTION DOWNWARD. FINISH TO BE SPACING. DEFLECTION DOWNWARD. FINISH TO BE SPACING. DEFLECTION DOWNWARD. FINISH TO BE DEFLECTION DOWNWARD. FINISH TO BE DEFLECTION DOWNWARD. FINISH TO BE DOWNWARD. FINISH TO BE DOWNWARD. FINISH TO BE FINISH TO BE FINISH TO BE TO BE TO BE BE BE SELECTED BY ARCHITECT.
AutoCAD SHX Text
RETURN AIR GRILLE/EXHAUST AIR GRILLE/EXHAUSTAIR GRILLE/EXHAUST
AutoCAD SHX Text
NO
AutoCAD SHX Text
E
AutoCAD SHX Text
LINEAR RETURN AIR DIFFUSER
AutoCAD SHX Text
SDR150
AutoCAD SHX Text
LENGTH AS INDICATED ON DRAWING, 2 SLOTS WITH 1-1/2" SLOT. FRAME STYLE TO SUIT CEILING TYPE, FINISH OFF WHITE AS INDICATED ON DRAWING, 2 SLOTS WITH 1-1/2" SLOT. FRAME STYLE TO SUIT CEILING TYPE, FINISH OFF WHITE AS INDICATED ON DRAWING, 2 SLOTS WITH 1-1/2" SLOT. FRAME STYLE TO SUIT CEILING TYPE, FINISH OFF WHITE INDICATED ON DRAWING, 2 SLOTS WITH 1-1/2" SLOT. FRAME STYLE TO SUIT CEILING TYPE, FINISH OFF WHITE INDICATED ON DRAWING, 2 SLOTS WITH 1-1/2" SLOT. FRAME STYLE TO SUIT CEILING TYPE, FINISH OFF WHITE ON DRAWING, 2 SLOTS WITH 1-1/2" SLOT. FRAME STYLE TO SUIT CEILING TYPE, FINISH OFF WHITE ON DRAWING, 2 SLOTS WITH 1-1/2" SLOT. FRAME STYLE TO SUIT CEILING TYPE, FINISH OFF WHITE DRAWING, 2 SLOTS WITH 1-1/2" SLOT. FRAME STYLE TO SUIT CEILING TYPE, FINISH OFF WHITE DRAWING, 2 SLOTS WITH 1-1/2" SLOT. FRAME STYLE TO SUIT CEILING TYPE, FINISH OFF WHITE 2 SLOTS WITH 1-1/2" SLOT. FRAME STYLE TO SUIT CEILING TYPE, FINISH OFF WHITE 2 SLOTS WITH 1-1/2" SLOT. FRAME STYLE TO SUIT CEILING TYPE, FINISH OFF WHITE SLOTS WITH 1-1/2" SLOT. FRAME STYLE TO SUIT CEILING TYPE, FINISH OFF WHITE SLOTS WITH 1-1/2" SLOT. FRAME STYLE TO SUIT CEILING TYPE, FINISH OFF WHITE WITH 1-1/2" SLOT. FRAME STYLE TO SUIT CEILING TYPE, FINISH OFF WHITE WITH 1-1/2" SLOT. FRAME STYLE TO SUIT CEILING TYPE, FINISH OFF WHITE 1-1/2" SLOT. FRAME STYLE TO SUIT CEILING TYPE, FINISH OFF WHITE 1-1/2" SLOT. FRAME STYLE TO SUIT CEILING TYPE, FINISH OFF WHITE SLOT. FRAME STYLE TO SUIT CEILING TYPE, FINISH OFF WHITE SLOT. FRAME STYLE TO SUIT CEILING TYPE, FINISH OFF WHITE FRAME STYLE TO SUIT CEILING TYPE, FINISH OFF WHITE FRAME STYLE TO SUIT CEILING TYPE, FINISH OFF WHITE STYLE TO SUIT CEILING TYPE, FINISH OFF WHITE STYLE TO SUIT CEILING TYPE, FINISH OFF WHITE TO SUIT CEILING TYPE, FINISH OFF WHITE TO SUIT CEILING TYPE, FINISH OFF WHITE SUIT CEILING TYPE, FINISH OFF WHITE SUIT CEILING TYPE, FINISH OFF WHITE CEILING TYPE, FINISH OFF WHITE CEILING TYPE, FINISH OFF WHITE TYPE, FINISH OFF WHITE TYPE, FINISH OFF WHITE FINISH OFF WHITE FINISH OFF WHITE OFF WHITE OFF WHITE WHITE WHITE BAKED ENAMEL, COLOR TO BE SELECTED BY ARCHITECT.
AutoCAD SHX Text
NO
AutoCAD SHX Text
F
AutoCAD SHX Text
JE443
AutoCAD SHX Text
METAL LOUVER, PAINT FINISHED. C/W BIRDSCREEN & MOTORIZED DAMPER; COLOUR AS DIRECTED BY ARCHITECT. SIZE LOUVER, PAINT FINISHED. C/W BIRDSCREEN & MOTORIZED DAMPER; COLOUR AS DIRECTED BY ARCHITECT. SIZE LOUVER, PAINT FINISHED. C/W BIRDSCREEN & MOTORIZED DAMPER; COLOUR AS DIRECTED BY ARCHITECT. SIZE PAINT FINISHED. C/W BIRDSCREEN & MOTORIZED DAMPER; COLOUR AS DIRECTED BY ARCHITECT. SIZE PAINT FINISHED. C/W BIRDSCREEN & MOTORIZED DAMPER; COLOUR AS DIRECTED BY ARCHITECT. SIZE FINISHED. C/W BIRDSCREEN & MOTORIZED DAMPER; COLOUR AS DIRECTED BY ARCHITECT. SIZE FINISHED. C/W BIRDSCREEN & MOTORIZED DAMPER; COLOUR AS DIRECTED BY ARCHITECT. SIZE C/W BIRDSCREEN & MOTORIZED DAMPER; COLOUR AS DIRECTED BY ARCHITECT. SIZE C/W BIRDSCREEN & MOTORIZED DAMPER; COLOUR AS DIRECTED BY ARCHITECT. SIZE BIRDSCREEN & MOTORIZED DAMPER; COLOUR AS DIRECTED BY ARCHITECT. SIZE BIRDSCREEN & MOTORIZED DAMPER; COLOUR AS DIRECTED BY ARCHITECT. SIZE & MOTORIZED DAMPER; COLOUR AS DIRECTED BY ARCHITECT. SIZE & MOTORIZED DAMPER; COLOUR AS DIRECTED BY ARCHITECT. SIZE MOTORIZED DAMPER; COLOUR AS DIRECTED BY ARCHITECT. SIZE MOTORIZED DAMPER; COLOUR AS DIRECTED BY ARCHITECT. SIZE DAMPER; COLOUR AS DIRECTED BY ARCHITECT. SIZE DAMPER; COLOUR AS DIRECTED BY ARCHITECT. SIZE COLOUR AS DIRECTED BY ARCHITECT. SIZE COLOUR AS DIRECTED BY ARCHITECT. SIZE AS DIRECTED BY ARCHITECT. SIZE AS DIRECTED BY ARCHITECT. SIZE DIRECTED BY ARCHITECT. SIZE DIRECTED BY ARCHITECT. SIZE BY ARCHITECT. SIZE BY ARCHITECT. SIZE ARCHITECT. SIZE ARCHITECT. SIZE SIZE SIZE AS INDICATED ON THE DRAWING.
AutoCAD SHX Text
FRESH AIR LOUVER
AutoCAD SHX Text
G
AutoCAD SHX Text
MOTORIZED DAMPER
AutoCAD SHX Text
25.4
AutoCAD SHX Text
GREENHECK/SP-A900
AutoCAD SHX Text
423
AutoCAD SHX Text
285
AutoCAD SHX Text
31
AutoCAD SHX Text
950
AutoCAD SHX Text
EXHAUST FAN
AutoCAD SHX Text
INTERLOCKED WITH MD-5
AutoCAD SHX Text
4.0
AutoCAD SHX Text
120
AutoCAD SHX Text
60
AutoCAD SHX Text
1
AutoCAD SHX Text
EF-5
AutoCAD SHX Text
297
AutoCAD SHX Text
0.03 OPEN
AutoCAD SHX Text
0.06 ENCLOSED
AutoCAD SHX Text
15
AutoCAD SHX Text
2.4
AutoCAD SHX Text
155
AutoCAD SHX Text
29.9
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
10.9
AutoCAD SHX Text
13.2
AutoCAD SHX Text
GAS HEATER; COORDINATE WITH ELECTRICAL DEPARTMENT FOR POWER SUPPLY
AutoCAD SHX Text
OAS15036AM
AutoCAD SHX Text
OUELLET
AutoCAD SHX Text
UH-2
AutoCAD SHX Text
614
AutoCAD SHX Text
1/8
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
35.6
AutoCAD SHX Text
15 KW
AutoCAD SHX Text
ELECTRICAL HEATER; 600V/3 .
AutoCAD SHX Text
2.0
AutoCAD SHX Text
RTU-2
AutoCAD SHX Text
7.2
AutoCAD SHX Text
5.44
AutoCAD SHX Text
378
AutoCAD SHX Text
54
AutoCAD SHX Text
208/1%%C/60
AutoCAD SHX Text
LENNOX/ KGB024S4D
AutoCAD SHX Text
19.1
AutoCAD SHX Text
15.24
AutoCAD SHX Text
250
AutoCAD SHX Text
290
AutoCAD SHX Text
YES
AutoCAD SHX Text
12.7
AutoCAD SHX Text
1/4
AutoCAD SHX Text
H
AutoCAD SHX Text
SUPPLY AIR LOUVER
AutoCAD SHX Text
520 SERIES/B12
AutoCAD SHX Text
YES
AutoCAD SHX Text
FINISH OFF WHITE BAKED ENAMEL C/W OPPOSED BLADE DAMPER., COLOR TO BE OFF WHITE BAKED ENAMEL C/W OPPOSED BLADE DAMPER., COLOR TO BE OFF WHITE BAKED ENAMEL C/W OPPOSED BLADE DAMPER., COLOR TO BE WHITE BAKED ENAMEL C/W OPPOSED BLADE DAMPER., COLOR TO BE WHITE BAKED ENAMEL C/W OPPOSED BLADE DAMPER., COLOR TO BE BAKED ENAMEL C/W OPPOSED BLADE DAMPER., COLOR TO BE BAKED ENAMEL C/W OPPOSED BLADE DAMPER., COLOR TO BE ENAMEL C/W OPPOSED BLADE DAMPER., COLOR TO BE ENAMEL C/W OPPOSED BLADE DAMPER., COLOR TO BE C/W OPPOSED BLADE DAMPER., COLOR TO BE C/W OPPOSED BLADE DAMPER., COLOR TO BE OPPOSED BLADE DAMPER., COLOR TO BE OPPOSED BLADE DAMPER., COLOR TO BE BLADE DAMPER., COLOR TO BE BLADE DAMPER., COLOR TO BE DAMPER., COLOR TO BE DAMPER., COLOR TO BE COLOR TO BE COLOR TO BE TO BE TO BE BE BE SELECTED BY ARCHITECT.
AutoCAD SHX Text
STANDARD HEAT
AutoCAD SHX Text
MEDIUM HEAT; POWER EXHAUST
AutoCAD SHX Text
HORIZONTAL DISCHARGE CONFIGURATION
AutoCAD SHX Text
120
AutoCAD SHX Text
60
AutoCAD SHX Text
1
AutoCAD SHX Text
-
AutoCAD SHX Text
I
AutoCAD SHX Text
TRANSFER GRILLE
AutoCAD SHX Text
STG
AutoCAD SHX Text
YES
AutoCAD SHX Text
HEAVY DUTY STEEL CONSTRUCT. SIGHT-PROOF. LOCATE AS HIGH AS POSSIBLE ON WALL.
AutoCAD SHX Text
8.6
AutoCAD SHX Text
7.9
AutoCAD SHX Text
BIG ASS FANS/HAIKU 60"
AutoCAD SHX Text
4072
AutoCAD SHX Text
56.8
AutoCAD SHX Text
-
AutoCAD SHX Text
200
AutoCAD SHX Text
CEILING FAN
AutoCAD SHX Text
ALUMINUM FINISH. UNIVERSAL MOUNT. USE 60" EXTENSION TUBE.
AutoCAD SHX Text
-
AutoCAD SHX Text
120
AutoCAD SHX Text
60
AutoCAD SHX Text
1
AutoCAD SHX Text
CF-1~10
AutoCAD SHX Text
OAS02008AM
AutoCAD SHX Text
OUELLET
AutoCAD SHX Text
240
AutoCAD SHX Text
1/30
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
9.1
AutoCAD SHX Text
2 KW
AutoCAD SHX Text
ELECTRICAL UNIT HEATER; 208V/1 . CONTROLLED BYTHERMOSTATS.
AutoCAD SHX Text
UH-3&4
AutoCAD SHX Text
D76
AutoCAD SHX Text
G7
AutoCAD SHX Text
D.6
AutoCAD SHX Text
-
AutoCAD SHX Text
549
AutoCAD SHX Text
0.500
AutoCAD SHX Text
1845
AutoCAD SHX Text
1.000
AutoCAD SHX Text
0.8250
AutoCAD SHX Text
1
AutoCAD SHX Text
115
AutoCAD SHX Text
8.1
AutoCAD SHX Text
158.3
AutoCAD SHX Text
24
AutoCAD SHX Text
TAG
AutoCAD SHX Text
FAN UNIT MODEL #
AutoCAD SHX Text
BLOWER
AutoCAD SHX Text
HOUSING
AutoCAD SHX Text
MIN CFM
AutoCAD SHX Text
DESIGN l/s
AutoCAD SHX Text
ESP.
AutoCAD SHX Text
RPM
AutoCAD SHX Text
H.P.
AutoCAD SHX Text
B.H.P.
AutoCAD SHX Text
AutoCAD SHX Text
VOLT
AutoCAD SHX Text
FLA
AutoCAD SHX Text
WEIGHT (KG)
AutoCAD SHX Text
SONES
AutoCAD SHX Text
MUA-1
AutoCAD SHX Text
SERVING AREA
AutoCAD SHX Text
KITCHED
AutoCAD SHX Text
ELECTRICAL ROOM
AutoCAD SHX Text
REFRIGERATION ROOM
AutoCAD SHX Text
WASHROOM & JANITOR
AutoCAD SHX Text
ZAMBONI GARAGE
AutoCAD SHX Text
MULTI-PURPOSE ROOM
AutoCAD SHX Text
WEIGHT (KG)
AutoCAD SHX Text
52.8
AutoCAD SHX Text
MCA
AutoCAD SHX Text
17
AutoCAD SHX Text
16
AutoCAD SHX Text
MOCP
AutoCAD SHX Text
20
AutoCAD SHX Text
25
AutoCAD SHX Text
J
AutoCAD SHX Text
61DGD-FR
AutoCAD SHX Text
NO
AutoCAD SHX Text
FIRE RATED DOOR GRILLE FOR JANITOR ROOM. SIZE SHALL BE AS INDICATED. COLOR TO BE SELECTED BY RATED DOOR GRILLE FOR JANITOR ROOM. SIZE SHALL BE AS INDICATED. COLOR TO BE SELECTED BY RATED DOOR GRILLE FOR JANITOR ROOM. SIZE SHALL BE AS INDICATED. COLOR TO BE SELECTED BY DOOR GRILLE FOR JANITOR ROOM. SIZE SHALL BE AS INDICATED. COLOR TO BE SELECTED BY DOOR GRILLE FOR JANITOR ROOM. SIZE SHALL BE AS INDICATED. COLOR TO BE SELECTED BY GRILLE FOR JANITOR ROOM. SIZE SHALL BE AS INDICATED. COLOR TO BE SELECTED BY GRILLE FOR JANITOR ROOM. SIZE SHALL BE AS INDICATED. COLOR TO BE SELECTED BY FOR JANITOR ROOM. SIZE SHALL BE AS INDICATED. COLOR TO BE SELECTED BY FOR JANITOR ROOM. SIZE SHALL BE AS INDICATED. COLOR TO BE SELECTED BY JANITOR ROOM. SIZE SHALL BE AS INDICATED. COLOR TO BE SELECTED BY JANITOR ROOM. SIZE SHALL BE AS INDICATED. COLOR TO BE SELECTED BY ROOM. SIZE SHALL BE AS INDICATED. COLOR TO BE SELECTED BY ROOM. SIZE SHALL BE AS INDICATED. COLOR TO BE SELECTED BY SIZE SHALL BE AS INDICATED. COLOR TO BE SELECTED BY SIZE SHALL BE AS INDICATED. COLOR TO BE SELECTED BY SHALL BE AS INDICATED. COLOR TO BE SELECTED BY SHALL BE AS INDICATED. COLOR TO BE SELECTED BY BE AS INDICATED. COLOR TO BE SELECTED BY BE AS INDICATED. COLOR TO BE SELECTED BY AS INDICATED. COLOR TO BE SELECTED BY AS INDICATED. COLOR TO BE SELECTED BY INDICATED. COLOR TO BE SELECTED BY INDICATED. COLOR TO BE SELECTED BY COLOR TO BE SELECTED BY COLOR TO BE SELECTED BY TO BE SELECTED BY TO BE SELECTED BY BE SELECTED BY BE SELECTED BY SELECTED BY SELECTED BY BY BY ARCHITECT.
AutoCAD SHX Text
FIRE RATED DOOR GRILLE (NAILOR)
AutoCAD SHX Text
OAC02006-T
AutoCAD SHX Text
OUELLET
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
12.7
AutoCAD SHX Text
2 KW
AutoCAD SHX Text
ELECTRICAL FORCE FLOW HEATER, 600V/3 .
AutoCAD SHX Text
FFH-1
AutoCAD SHX Text
189 L/M
AutoCAD SHX Text
45.0 KG
AutoCAD SHX Text
GREASE TRAP IS CORROSION-RESISTANT COATED FABRICATED STEEL WITH NO-HUB CONNECTIONS, FLOW DIFFUSING BAFFLE, INTEGRAL TRAP, AND VENTED INLET FLOW CONTROL DEVICE.
AutoCAD SHX Text
ITEM
AutoCAD SHX Text
MAKE/MODEL
AutoCAD SHX Text
FLOW RATE
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
GREASE CAPACITY
AutoCAD SHX Text
GREASE INTERCEPTOR GI-1
AutoCAD SHX Text
ZURN/ GT2700-50
AutoCAD SHX Text
MECHANICAL SCHEDULE-1
AutoCAD SHX Text
M6.1
AutoCAD SHX Text
PH.: (905) 946 4260 FAX: (905) 946 0901
AutoCAD SHX Text
MARKHAM ONTARIO L3R 1A3
AutoCAD SHX Text
UNIT 229
AutoCAD SHX Text
7181 WOODBINE AVE
AutoCAD SHX Text
%%UTHOMAS A. FEKETE LIMITED

PLUMBING FIXTURE SCHEDULE

DATE INITIALREVISIONSNo.

DESIGN

DATE:

DRAWNCHECKED

DRAWING NUMBER

SIGNED

SCALE: CONTRACT No.

2019-11-01 ISSUED FOR 60% CONSTRUCTION DOCUMENTS1

WS2492514132

CITY ASSET No. 297

DUFFERIN GROVE PARK NORTH-WEST CORNER

AND CLUBHOUSE IMPROVEMENTS

DR

AW

IN

G P

RIN

T D

AT

E: 7/10/2020 5:04:23 P

M

FIL

EN

AM

E: \\T

AF

_S

ER

VE

R\taf_m

ain

\P

ro

jects\C

urren

t P

ro

jects\18173 D

UF

FE

RIN

G

RO

VE

P

AR

K IM

PR

OV

EM

EN

TS

\300 D

esig

n\301 M

E D

wg

s\18173 M

EC

H\18173

m m

etric.d

wg

YA YA BZ

JOB NUMBER: 18173

2020-01-17 ISSUED FOR 90% COORDINATION2

2020-02-14 PROGRESS SET3

2020-03-06 ISSUED FOR PERMIT4

2020-03-06

2020-03-24 ISSUED FOR CD'S5

2020-06-12

2020-06-12 ISSUED FOR TENDER6

AutoCAD SHX Text
EPOXY COATED, CAST IRON BODY, 5" (127 MM) ROUND ADJUSTABLE GASKETED NICKEL BRONZE TOP, ABS PLUG WITH NEOPRENE GASKET, NO HUB OUTLET.
AutoCAD SHX Text
TAG
AutoCAD SHX Text
FIXTURE
AutoCAD SHX Text
MAKE/MODEL
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
CLEAN OUT
AutoCAD SHX Text
WATTS /#CO-200-R-34G
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
BOTTLE FILLING STATION PEDESTAL, NON-FILTERED NON-REFRIGERATED. FEATURES SHALL INCLUDE E-COAT, HEAVY DUTY VANDAL-RESISTANT, LAMINAR FLOW. FRONT BUBBLER FILLING STATION PEDESTAL, NON-FILTERED NON-REFRIGERATED. FEATURES SHALL INCLUDE E-COAT, HEAVY DUTY VANDAL-RESISTANT, LAMINAR FLOW. FRONT BUBBLER FILLING STATION PEDESTAL, NON-FILTERED NON-REFRIGERATED. FEATURES SHALL INCLUDE E-COAT, HEAVY DUTY VANDAL-RESISTANT, LAMINAR FLOW. FRONT BUBBLER STATION PEDESTAL, NON-FILTERED NON-REFRIGERATED. FEATURES SHALL INCLUDE E-COAT, HEAVY DUTY VANDAL-RESISTANT, LAMINAR FLOW. FRONT BUBBLER STATION PEDESTAL, NON-FILTERED NON-REFRIGERATED. FEATURES SHALL INCLUDE E-COAT, HEAVY DUTY VANDAL-RESISTANT, LAMINAR FLOW. FRONT BUBBLER PEDESTAL, NON-FILTERED NON-REFRIGERATED. FEATURES SHALL INCLUDE E-COAT, HEAVY DUTY VANDAL-RESISTANT, LAMINAR FLOW. FRONT BUBBLER PEDESTAL, NON-FILTERED NON-REFRIGERATED. FEATURES SHALL INCLUDE E-COAT, HEAVY DUTY VANDAL-RESISTANT, LAMINAR FLOW. FRONT BUBBLER NON-FILTERED NON-REFRIGERATED. FEATURES SHALL INCLUDE E-COAT, HEAVY DUTY VANDAL-RESISTANT, LAMINAR FLOW. FRONT BUBBLER NON-FILTERED NON-REFRIGERATED. FEATURES SHALL INCLUDE E-COAT, HEAVY DUTY VANDAL-RESISTANT, LAMINAR FLOW. FRONT BUBBLER NON-REFRIGERATED. FEATURES SHALL INCLUDE E-COAT, HEAVY DUTY VANDAL-RESISTANT, LAMINAR FLOW. FRONT BUBBLER NON-REFRIGERATED. FEATURES SHALL INCLUDE E-COAT, HEAVY DUTY VANDAL-RESISTANT, LAMINAR FLOW. FRONT BUBBLER FEATURES SHALL INCLUDE E-COAT, HEAVY DUTY VANDAL-RESISTANT, LAMINAR FLOW. FRONT BUBBLER FEATURES SHALL INCLUDE E-COAT, HEAVY DUTY VANDAL-RESISTANT, LAMINAR FLOW. FRONT BUBBLER SHALL INCLUDE E-COAT, HEAVY DUTY VANDAL-RESISTANT, LAMINAR FLOW. FRONT BUBBLER SHALL INCLUDE E-COAT, HEAVY DUTY VANDAL-RESISTANT, LAMINAR FLOW. FRONT BUBBLER INCLUDE E-COAT, HEAVY DUTY VANDAL-RESISTANT, LAMINAR FLOW. FRONT BUBBLER INCLUDE E-COAT, HEAVY DUTY VANDAL-RESISTANT, LAMINAR FLOW. FRONT BUBBLER E-COAT, HEAVY DUTY VANDAL-RESISTANT, LAMINAR FLOW. FRONT BUBBLER E-COAT, HEAVY DUTY VANDAL-RESISTANT, LAMINAR FLOW. FRONT BUBBLER HEAVY DUTY VANDAL-RESISTANT, LAMINAR FLOW. FRONT BUBBLER HEAVY DUTY VANDAL-RESISTANT, LAMINAR FLOW. FRONT BUBBLER DUTY VANDAL-RESISTANT, LAMINAR FLOW. FRONT BUBBLER DUTY VANDAL-RESISTANT, LAMINAR FLOW. FRONT BUBBLER VANDAL-RESISTANT, LAMINAR FLOW. FRONT BUBBLER VANDAL-RESISTANT, LAMINAR FLOW. FRONT BUBBLER LAMINAR FLOW. FRONT BUBBLER LAMINAR FLOW. FRONT BUBBLER FLOW. FRONT BUBBLER FLOW. FRONT BUBBLER FRONT BUBBLER FRONT BUBBLER BUBBLER BUBBLER BUTTON ACTIVATION. PRODUCT SHALL BE FLOOR MOUNT/FREESTANDING, FOR OUTDOOR APPLICATIONS, SERVING 1 STATION(S). UNIT SHALL BE LEAD-FREE DESIGN WHICH IS ACTIVATION. PRODUCT SHALL BE FLOOR MOUNT/FREESTANDING, FOR OUTDOOR APPLICATIONS, SERVING 1 STATION(S). UNIT SHALL BE LEAD-FREE DESIGN WHICH IS ACTIVATION. PRODUCT SHALL BE FLOOR MOUNT/FREESTANDING, FOR OUTDOOR APPLICATIONS, SERVING 1 STATION(S). UNIT SHALL BE LEAD-FREE DESIGN WHICH IS PRODUCT SHALL BE FLOOR MOUNT/FREESTANDING, FOR OUTDOOR APPLICATIONS, SERVING 1 STATION(S). UNIT SHALL BE LEAD-FREE DESIGN WHICH IS PRODUCT SHALL BE FLOOR MOUNT/FREESTANDING, FOR OUTDOOR APPLICATIONS, SERVING 1 STATION(S). UNIT SHALL BE LEAD-FREE DESIGN WHICH IS SHALL BE FLOOR MOUNT/FREESTANDING, FOR OUTDOOR APPLICATIONS, SERVING 1 STATION(S). UNIT SHALL BE LEAD-FREE DESIGN WHICH IS SHALL BE FLOOR MOUNT/FREESTANDING, FOR OUTDOOR APPLICATIONS, SERVING 1 STATION(S). UNIT SHALL BE LEAD-FREE DESIGN WHICH IS BE FLOOR MOUNT/FREESTANDING, FOR OUTDOOR APPLICATIONS, SERVING 1 STATION(S). UNIT SHALL BE LEAD-FREE DESIGN WHICH IS BE FLOOR MOUNT/FREESTANDING, FOR OUTDOOR APPLICATIONS, SERVING 1 STATION(S). UNIT SHALL BE LEAD-FREE DESIGN WHICH IS FLOOR MOUNT/FREESTANDING, FOR OUTDOOR APPLICATIONS, SERVING 1 STATION(S). UNIT SHALL BE LEAD-FREE DESIGN WHICH IS FLOOR MOUNT/FREESTANDING, FOR OUTDOOR APPLICATIONS, SERVING 1 STATION(S). UNIT SHALL BE LEAD-FREE DESIGN WHICH IS MOUNT/FREESTANDING, FOR OUTDOOR APPLICATIONS, SERVING 1 STATION(S). UNIT SHALL BE LEAD-FREE DESIGN WHICH IS MOUNT/FREESTANDING, FOR OUTDOOR APPLICATIONS, SERVING 1 STATION(S). UNIT SHALL BE LEAD-FREE DESIGN WHICH IS FOR OUTDOOR APPLICATIONS, SERVING 1 STATION(S). UNIT SHALL BE LEAD-FREE DESIGN WHICH IS FOR OUTDOOR APPLICATIONS, SERVING 1 STATION(S). UNIT SHALL BE LEAD-FREE DESIGN WHICH IS OUTDOOR APPLICATIONS, SERVING 1 STATION(S). UNIT SHALL BE LEAD-FREE DESIGN WHICH IS OUTDOOR APPLICATIONS, SERVING 1 STATION(S). UNIT SHALL BE LEAD-FREE DESIGN WHICH IS APPLICATIONS, SERVING 1 STATION(S). UNIT SHALL BE LEAD-FREE DESIGN WHICH IS APPLICATIONS, SERVING 1 STATION(S). UNIT SHALL BE LEAD-FREE DESIGN WHICH IS SERVING 1 STATION(S). UNIT SHALL BE LEAD-FREE DESIGN WHICH IS SERVING 1 STATION(S). UNIT SHALL BE LEAD-FREE DESIGN WHICH IS 1 STATION(S). UNIT SHALL BE LEAD-FREE DESIGN WHICH IS 1 STATION(S). UNIT SHALL BE LEAD-FREE DESIGN WHICH IS STATION(S). UNIT SHALL BE LEAD-FREE DESIGN WHICH IS STATION(S). UNIT SHALL BE LEAD-FREE DESIGN WHICH IS UNIT SHALL BE LEAD-FREE DESIGN WHICH IS UNIT SHALL BE LEAD-FREE DESIGN WHICH IS SHALL BE LEAD-FREE DESIGN WHICH IS SHALL BE LEAD-FREE DESIGN WHICH IS BE LEAD-FREE DESIGN WHICH IS BE LEAD-FREE DESIGN WHICH IS LEAD-FREE DESIGN WHICH IS LEAD-FREE DESIGN WHICH IS DESIGN WHICH IS DESIGN WHICH IS WHICH IS WHICH IS IS IS CERTIFIED TO NSF/ANSI 61 & 372 (LEAD FREE) AND MEETS LOCAL LOW-LEAD REQUIREMENTS.
AutoCAD SHX Text
ELKAY/EZH20-LK4400BF
AutoCAD SHX Text
BOTTLE FILLER
AutoCAD SHX Text
BF
AutoCAD SHX Text
EPOXY COATED, CAST IRON BODY, REVERSIBLE FLASHING CLAMP WITH PRIMARY AND SECONDARY WEEPHOLES, TRAP PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS COATED, CAST IRON BODY, REVERSIBLE FLASHING CLAMP WITH PRIMARY AND SECONDARY WEEPHOLES, TRAP PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS COATED, CAST IRON BODY, REVERSIBLE FLASHING CLAMP WITH PRIMARY AND SECONDARY WEEPHOLES, TRAP PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS CAST IRON BODY, REVERSIBLE FLASHING CLAMP WITH PRIMARY AND SECONDARY WEEPHOLES, TRAP PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS CAST IRON BODY, REVERSIBLE FLASHING CLAMP WITH PRIMARY AND SECONDARY WEEPHOLES, TRAP PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS IRON BODY, REVERSIBLE FLASHING CLAMP WITH PRIMARY AND SECONDARY WEEPHOLES, TRAP PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS IRON BODY, REVERSIBLE FLASHING CLAMP WITH PRIMARY AND SECONDARY WEEPHOLES, TRAP PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS BODY, REVERSIBLE FLASHING CLAMP WITH PRIMARY AND SECONDARY WEEPHOLES, TRAP PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS BODY, REVERSIBLE FLASHING CLAMP WITH PRIMARY AND SECONDARY WEEPHOLES, TRAP PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS REVERSIBLE FLASHING CLAMP WITH PRIMARY AND SECONDARY WEEPHOLES, TRAP PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS REVERSIBLE FLASHING CLAMP WITH PRIMARY AND SECONDARY WEEPHOLES, TRAP PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS FLASHING CLAMP WITH PRIMARY AND SECONDARY WEEPHOLES, TRAP PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS FLASHING CLAMP WITH PRIMARY AND SECONDARY WEEPHOLES, TRAP PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS CLAMP WITH PRIMARY AND SECONDARY WEEPHOLES, TRAP PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS CLAMP WITH PRIMARY AND SECONDARY WEEPHOLES, TRAP PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS WITH PRIMARY AND SECONDARY WEEPHOLES, TRAP PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS WITH PRIMARY AND SECONDARY WEEPHOLES, TRAP PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS PRIMARY AND SECONDARY WEEPHOLES, TRAP PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS PRIMARY AND SECONDARY WEEPHOLES, TRAP PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS AND SECONDARY WEEPHOLES, TRAP PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS AND SECONDARY WEEPHOLES, TRAP PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS SECONDARY WEEPHOLES, TRAP PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS SECONDARY WEEPHOLES, TRAP PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS WEEPHOLES, TRAP PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS WEEPHOLES, TRAP PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS TRAP PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS TRAP PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS CONNECTION WITH PLUG, NO HUB OUTLET. WATTS CONNECTION WITH PLUG, NO HUB OUTLET. WATTS WITH PLUG, NO HUB OUTLET. WATTS WITH PLUG, NO HUB OUTLET. WATTS PLUG, NO HUB OUTLET. WATTS PLUG, NO HUB OUTLET. WATTS NO HUB OUTLET. WATTS NO HUB OUTLET. WATTS HUB OUTLET. WATTS HUB OUTLET. WATTS OUTLET. WATTS OUTLET. WATTS WATTS WATTS -A5-1 5" (127 MM) DIAMETER, NICKEL BRONZE, ADJUSTABLE ROUND STRAINER.
AutoCAD SHX Text
FLOOR DRAIN
AutoCAD SHX Text
WATTS /#FD-100-C-7-A5-1
AutoCAD SHX Text
FD
AutoCAD SHX Text
EPOXY COATED, CAST IRON BODY, BODY COLLAR WITH WEEPHOLES AND MEMBRANE CLAMP, TRAP PRIMER CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS COATED, CAST IRON BODY, BODY COLLAR WITH WEEPHOLES AND MEMBRANE CLAMP, TRAP PRIMER CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS COATED, CAST IRON BODY, BODY COLLAR WITH WEEPHOLES AND MEMBRANE CLAMP, TRAP PRIMER CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS CAST IRON BODY, BODY COLLAR WITH WEEPHOLES AND MEMBRANE CLAMP, TRAP PRIMER CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS CAST IRON BODY, BODY COLLAR WITH WEEPHOLES AND MEMBRANE CLAMP, TRAP PRIMER CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS IRON BODY, BODY COLLAR WITH WEEPHOLES AND MEMBRANE CLAMP, TRAP PRIMER CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS IRON BODY, BODY COLLAR WITH WEEPHOLES AND MEMBRANE CLAMP, TRAP PRIMER CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS BODY, BODY COLLAR WITH WEEPHOLES AND MEMBRANE CLAMP, TRAP PRIMER CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS BODY, BODY COLLAR WITH WEEPHOLES AND MEMBRANE CLAMP, TRAP PRIMER CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS BODY COLLAR WITH WEEPHOLES AND MEMBRANE CLAMP, TRAP PRIMER CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS BODY COLLAR WITH WEEPHOLES AND MEMBRANE CLAMP, TRAP PRIMER CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS COLLAR WITH WEEPHOLES AND MEMBRANE CLAMP, TRAP PRIMER CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS COLLAR WITH WEEPHOLES AND MEMBRANE CLAMP, TRAP PRIMER CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS WITH WEEPHOLES AND MEMBRANE CLAMP, TRAP PRIMER CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS WITH WEEPHOLES AND MEMBRANE CLAMP, TRAP PRIMER CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS WEEPHOLES AND MEMBRANE CLAMP, TRAP PRIMER CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS WEEPHOLES AND MEMBRANE CLAMP, TRAP PRIMER CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS AND MEMBRANE CLAMP, TRAP PRIMER CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS AND MEMBRANE CLAMP, TRAP PRIMER CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS MEMBRANE CLAMP, TRAP PRIMER CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS MEMBRANE CLAMP, TRAP PRIMER CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS CLAMP, TRAP PRIMER CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS CLAMP, TRAP PRIMER CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS TRAP PRIMER CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS TRAP PRIMER CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS PRIMER CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS PRIMER CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS ANCHOR FLANGE, NO HUB OUTLET. WATTS ANCHOR FLANGE, NO HUB OUTLET. WATTS FLANGE, NO HUB OUTLET. WATTS FLANGE, NO HUB OUTLET. WATTS NO HUB OUTLET. WATTS NO HUB OUTLET. WATTS HUB OUTLET. WATTS HUB OUTLET. WATTS OUTLET. WATTS OUTLET. WATTS WATTS WATTS -4-G-50 7-7/8" (200 MM) DIAMETER EPOXY COATED DUCTILE IRON, HEEL-PROOF ROUND GRATE, 4" X 9" (102 MM X 229 MM) OVAL CAST IRON FUNNEL.
AutoCAD SHX Text
FUNNEL FLOOR DRAIN
AutoCAD SHX Text
WATTS /#FD-100-C-7-G-50
AutoCAD SHX Text
FFD
AutoCAD SHX Text
LAVATORY
AutoCAD SHX Text
L-2
AutoCAD SHX Text
NON-FREEZE HYDRANT, ECOLOTROL CERAMIC DISC WALL HYDRANT, ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH HYDRANT, ECOLOTROL CERAMIC DISC WALL HYDRANT, ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH HYDRANT, ECOLOTROL CERAMIC DISC WALL HYDRANT, ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH ECOLOTROL CERAMIC DISC WALL HYDRANT, ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH ECOLOTROL CERAMIC DISC WALL HYDRANT, ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH CERAMIC DISC WALL HYDRANT, ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH CERAMIC DISC WALL HYDRANT, ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH DISC WALL HYDRANT, ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH DISC WALL HYDRANT, ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH WALL HYDRANT, ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH WALL HYDRANT, ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH HYDRANT, ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH HYDRANT, ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH AND INSTALL ALL NECESSARY COMPLY WITH AND INSTALL ALL NECESSARY COMPLY WITH INSTALL ALL NECESSARY COMPLY WITH INSTALL ALL NECESSARY COMPLY WITH ALL NECESSARY COMPLY WITH ALL NECESSARY COMPLY WITH NECESSARY COMPLY WITH NECESSARY COMPLY WITH COMPLY WITH COMPLY WITH WITH WITH MANUFACTURER'S RECOMMENDATION KITS.
AutoCAD SHX Text
ZURN/Z1320
AutoCAD SHX Text
NFHB
AutoCAD SHX Text
NON-FREEZED HOSE BIBB
AutoCAD SHX Text
TRAP SEAL PRIMER ACTIVATED BY A 3/4" (19 MM) NORMALLY CLOSED SOLENOID VALVE, DESIGNED TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS SEAL PRIMER ACTIVATED BY A 3/4" (19 MM) NORMALLY CLOSED SOLENOID VALVE, DESIGNED TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS SEAL PRIMER ACTIVATED BY A 3/4" (19 MM) NORMALLY CLOSED SOLENOID VALVE, DESIGNED TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS PRIMER ACTIVATED BY A 3/4" (19 MM) NORMALLY CLOSED SOLENOID VALVE, DESIGNED TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS PRIMER ACTIVATED BY A 3/4" (19 MM) NORMALLY CLOSED SOLENOID VALVE, DESIGNED TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS ACTIVATED BY A 3/4" (19 MM) NORMALLY CLOSED SOLENOID VALVE, DESIGNED TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS ACTIVATED BY A 3/4" (19 MM) NORMALLY CLOSED SOLENOID VALVE, DESIGNED TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS BY A 3/4" (19 MM) NORMALLY CLOSED SOLENOID VALVE, DESIGNED TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS BY A 3/4" (19 MM) NORMALLY CLOSED SOLENOID VALVE, DESIGNED TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS A 3/4" (19 MM) NORMALLY CLOSED SOLENOID VALVE, DESIGNED TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS A 3/4" (19 MM) NORMALLY CLOSED SOLENOID VALVE, DESIGNED TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS 3/4" (19 MM) NORMALLY CLOSED SOLENOID VALVE, DESIGNED TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS 3/4" (19 MM) NORMALLY CLOSED SOLENOID VALVE, DESIGNED TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS (19 MM) NORMALLY CLOSED SOLENOID VALVE, DESIGNED TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS (19 MM) NORMALLY CLOSED SOLENOID VALVE, DESIGNED TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS MM) NORMALLY CLOSED SOLENOID VALVE, DESIGNED TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS MM) NORMALLY CLOSED SOLENOID VALVE, DESIGNED TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS NORMALLY CLOSED SOLENOID VALVE, DESIGNED TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS NORMALLY CLOSED SOLENOID VALVE, DESIGNED TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS CLOSED SOLENOID VALVE, DESIGNED TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS CLOSED SOLENOID VALVE, DESIGNED TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS SOLENOID VALVE, DESIGNED TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS SOLENOID VALVE, DESIGNED TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS VALVE, DESIGNED TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS VALVE, DESIGNED TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS DESIGNED TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS DESIGNED TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS TO INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS INTERFACE WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS WITH LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS LOW VOLTAGE ENERGY MANAGEMENT SYSTEMS VOLTAGE ENERGY MANAGEMENT SYSTEMS VOLTAGE ENERGY MANAGEMENT SYSTEMS ENERGY MANAGEMENT SYSTEMS ENERGY MANAGEMENT SYSTEMS MANAGEMENT SYSTEMS MANAGEMENT SYSTEMS SYSTEMS SYSTEMS CONTROL, 3/4" (19 MM) DIAMETER CONNECTION ANTI-SIPHON ATMOSPHERIC VACUUM BREAKER.
AutoCAD SHX Text
P.P.P./#PT-4
AutoCAD SHX Text
TSP
AutoCAD SHX Text
TRAP SEAL PRIMER
AutoCAD SHX Text
WATER CLOSET
AutoCAD SHX Text
WC-1
AutoCAD SHX Text
P.P.P. #SC-500A WATER HAMMER ARRESTOR BARREL-FABRICATED OF TYPE "L" HARD DRAWN COPPER, COPPER OR FREE TURNING BRASS FOR CAP,1/2"Ø (13 MM) PIPE SIZE FOR 1-11 FIXTURE UNITS, MACHINED OF D69300 ECO LOW LEAD BRASS OR POLYCARBONATE DOW CALIBRE 2016-15MFR PISTON,EPDM O-RINGS,DOW-CORNING SILICONE COMPOUND #111, FDA LISTED FOR USE IN POTABLE WATER SYSTEM LUBRICANT,NICKEL PLATED FOR SALT WATER APPLICATION,DESIGNED TO OPERATE ON ALL DOMESTIC AND COMMERCIAL SYSTEMS. NORMAL OPERATING PRESSURE 0 TO 200 PSIG, MAX SPIKE PRESSURE OF 400 PSIG, MAY BE INSTALLED IN NEW OR EXISTING PLUMBING SYSTEMS WITH A STANDARD PIPE TEE. MAINTENANCE FREE-THE PISTON IS THE ONLY MOVING PART.
AutoCAD SHX Text
AMERICAN STANDARD/ #3351.101.020
AutoCAD SHX Text
WHA
AutoCAD SHX Text
WATER HAMMER ARRESTOR
AutoCAD SHX Text
1. PROVIDE ALL REQUIRED ACCESSORIES TO SUIT ARCHITECTURAL DETAILS. PROVIDE ALL REQUIRED ACCESSORIES TO SUIT ARCHITECTURAL DETAILS. 2. CONFIRM EXACT TYPE OF FLOOR ASSEMBLY WITH ARCHITECTURAL DIVISION PRIOR TO ORDERING.CONFIRM EXACT TYPE OF FLOOR ASSEMBLY WITH ARCHITECTURAL DIVISION PRIOR TO ORDERING.
AutoCAD SHX Text
WALL0HUNG SINK, VITREOUS CHINA. FRONT OVERFLOW. FAUCET HOLES ON 102MM CENTERS. FAUCET SHALL BE FROM MOEN. M-DURA CHROME TWO-HANDLE LAVATORY FAUCET #8278SMF12. BRASS SPOUT AND METAL HANDLE CONSTRUCTION WITH CHROME PLATED FINISH. 1/2" IPS CONNECTIONS. 4" CENTER REST. VANDAL RESISTANT TORX HEAD SCREWS. VANDAL RESISTANT LAMINAR FLOW AERATOR LIMITED TO 5.7L/M. MCGUIRE #155A OPEN GRID DRAIN, CAST BRASS ONE PIECE TOP, 17 GA. (1.5 MM) TUBULAR 32 MM (1-1/4") TAILPIECE. MCGUIRE #LFH170BVRB, FAUCET SUPPLIES, CHROME PLATED POLISHED BRASS, COMMERCIAL DUTY 1/4 TURN BALL VALVE ANGLE STOPS, 13 MM (1/2") I.D. INLET X 127 MM (5") HORIZONTAL EXTENSION TUBES, COMBINATION V.P. LOOSE KEY HANDLES, ESCUTCHEON AND STAINLESS STEEL BRAIDED FLEXIBLE RISERS. MCGUIRE #8872C P-TRAP, HEAVY CAST BRASS ADJUSTABLE BODY, WITH SLIP NUT, 32 MM (1-1/4") SIZE, SHALLOW WALL FLANGE AND SEAMLESS TUBULAR WALL BEND. WATTS #WCA-411-CA-481, BASIN CARRIER, CONCEALED ARMS, WALL FLANGES TO ATTACH TO BACKING PLATE SECURED IN WALL WITH LOCKING DEVICE AND LEVELLING SCREWS, HEAVY GAUGE STEEL UPRIGHTS WITH INTEGRAL WELDED FEET.
AutoCAD SHX Text
LAVATORY
AutoCAD SHX Text
L-1
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
ZURN/ Z105
AutoCAD SHX Text
ROOF DRAIN
AutoCAD SHX Text
RD-1~5
AutoCAD SHX Text
15" DIAMETER CONTROL-FLO ROOF DRAIN FOR DEAD-LEVEL ROOF CONSTRUCTION, DURA-COATED CAST IRON BODY, CONTROL-FLO WEIR SHALL BE LINEAR FUNCTIONING WITH INTEGRAL MEMBRANE FLASHING CLAMP/ GRAVEL GUARD AND POLY-DOME. ALL DATA SHALL BE VERIFIED PROPORTIONAL TO FLOW RATES. EACH NOTCH WILL ALLOW 10 GPM OF FLOW PER 1" OF RAIN WATER BUILD UP ABOVE THE DRAIN.
AutoCAD SHX Text
TRENCH DRAIN
AutoCAD SHX Text
TD-1
AutoCAD SHX Text
J.R. SMITH 9812
AutoCAD SHX Text
HEAVY DUTY BODY AND GRATE, 9812-M GRATE
AutoCAD SHX Text
HB
AutoCAD SHX Text
HOSE BIBB
AutoCAD SHX Text
AMERICAN STANDARD/ #3351.660 (BARRIER-FREE)
AutoCAD SHX Text
WALL MOUNT EYEWASH STATION FROM ULINE. CORROSION RESISTANT STALINLESS STEEL BOWL FOR HARSH ENVIRONMENTS AND OUTDOOR USE. TWIN SPRAY HEADS. FLIP-TOP DUST COVERS. BUILT-IN FILTERS FOR CLEAN WATER. PLUMBING REQUIRED. INCLUDES EYEWASH STATION, EMERGENCY SIGN AND INSPECTION TAG.
AutoCAD SHX Text
ULINE/ H5795
AutoCAD SHX Text
EW
AutoCAD SHX Text
EYE WASH STATION
AutoCAD SHX Text
AFWALL MILLENIUM 1.6 GPF FLUSHOMETER TOILET WITH EVERCLEAN. HIGH EFFICIENCY, 1.1~1.6 GPF. ADJUSTABLE TAILPIECE FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED MILLENIUM 1.6 GPF FLUSHOMETER TOILET WITH EVERCLEAN. HIGH EFFICIENCY, 1.1~1.6 GPF. ADJUSTABLE TAILPIECE FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED MILLENIUM 1.6 GPF FLUSHOMETER TOILET WITH EVERCLEAN. HIGH EFFICIENCY, 1.1~1.6 GPF. ADJUSTABLE TAILPIECE FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED 1.6 GPF FLUSHOMETER TOILET WITH EVERCLEAN. HIGH EFFICIENCY, 1.1~1.6 GPF. ADJUSTABLE TAILPIECE FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED 1.6 GPF FLUSHOMETER TOILET WITH EVERCLEAN. HIGH EFFICIENCY, 1.1~1.6 GPF. ADJUSTABLE TAILPIECE FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED GPF FLUSHOMETER TOILET WITH EVERCLEAN. HIGH EFFICIENCY, 1.1~1.6 GPF. ADJUSTABLE TAILPIECE FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED GPF FLUSHOMETER TOILET WITH EVERCLEAN. HIGH EFFICIENCY, 1.1~1.6 GPF. ADJUSTABLE TAILPIECE FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED FLUSHOMETER TOILET WITH EVERCLEAN. HIGH EFFICIENCY, 1.1~1.6 GPF. ADJUSTABLE TAILPIECE FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED FLUSHOMETER TOILET WITH EVERCLEAN. HIGH EFFICIENCY, 1.1~1.6 GPF. ADJUSTABLE TAILPIECE FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED TOILET WITH EVERCLEAN. HIGH EFFICIENCY, 1.1~1.6 GPF. ADJUSTABLE TAILPIECE FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED TOILET WITH EVERCLEAN. HIGH EFFICIENCY, 1.1~1.6 GPF. ADJUSTABLE TAILPIECE FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED WITH EVERCLEAN. HIGH EFFICIENCY, 1.1~1.6 GPF. ADJUSTABLE TAILPIECE FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED WITH EVERCLEAN. HIGH EFFICIENCY, 1.1~1.6 GPF. ADJUSTABLE TAILPIECE FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED EVERCLEAN. HIGH EFFICIENCY, 1.1~1.6 GPF. ADJUSTABLE TAILPIECE FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED EVERCLEAN. HIGH EFFICIENCY, 1.1~1.6 GPF. ADJUSTABLE TAILPIECE FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED HIGH EFFICIENCY, 1.1~1.6 GPF. ADJUSTABLE TAILPIECE FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED HIGH EFFICIENCY, 1.1~1.6 GPF. ADJUSTABLE TAILPIECE FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED EFFICIENCY, 1.1~1.6 GPF. ADJUSTABLE TAILPIECE FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED EFFICIENCY, 1.1~1.6 GPF. ADJUSTABLE TAILPIECE FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED 1.1~1.6 GPF. ADJUSTABLE TAILPIECE FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED 1.1~1.6 GPF. ADJUSTABLE TAILPIECE FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED GPF. ADJUSTABLE TAILPIECE FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED GPF. ADJUSTABLE TAILPIECE FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED ADJUSTABLE TAILPIECE FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED ADJUSTABLE TAILPIECE FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED TAILPIECE FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED TAILPIECE FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED FOR ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED ROUGH-IN FLEXIBILITY. POWERFUL DIRECT-FED FLEXIBILITY. POWERFUL DIRECT-FED FLEXIBILITY. POWERFUL DIRECT-FED POWERFUL DIRECT-FED POWERFUL DIRECT-FED DIRECT-FED DIRECT-FED SIPHON JET ACTION. 10"X12" WATER SURFACE AREA. 1-1/2" INLET SPUD. MANUAL FLUSH VALVE FROM MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP JET ACTION. 10"X12" WATER SURFACE AREA. 1-1/2" INLET SPUD. MANUAL FLUSH VALVE FROM MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP JET ACTION. 10"X12" WATER SURFACE AREA. 1-1/2" INLET SPUD. MANUAL FLUSH VALVE FROM MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP ACTION. 10"X12" WATER SURFACE AREA. 1-1/2" INLET SPUD. MANUAL FLUSH VALVE FROM MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP ACTION. 10"X12" WATER SURFACE AREA. 1-1/2" INLET SPUD. MANUAL FLUSH VALVE FROM MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP 10"X12" WATER SURFACE AREA. 1-1/2" INLET SPUD. MANUAL FLUSH VALVE FROM MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP 10"X12" WATER SURFACE AREA. 1-1/2" INLET SPUD. MANUAL FLUSH VALVE FROM MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP WATER SURFACE AREA. 1-1/2" INLET SPUD. MANUAL FLUSH VALVE FROM MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP WATER SURFACE AREA. 1-1/2" INLET SPUD. MANUAL FLUSH VALVE FROM MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP SURFACE AREA. 1-1/2" INLET SPUD. MANUAL FLUSH VALVE FROM MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP SURFACE AREA. 1-1/2" INLET SPUD. MANUAL FLUSH VALVE FROM MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP AREA. 1-1/2" INLET SPUD. MANUAL FLUSH VALVE FROM MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP AREA. 1-1/2" INLET SPUD. MANUAL FLUSH VALVE FROM MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP 1-1/2" INLET SPUD. MANUAL FLUSH VALVE FROM MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP 1-1/2" INLET SPUD. MANUAL FLUSH VALVE FROM MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP INLET SPUD. MANUAL FLUSH VALVE FROM MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP INLET SPUD. MANUAL FLUSH VALVE FROM MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP SPUD. MANUAL FLUSH VALVE FROM MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP SPUD. MANUAL FLUSH VALVE FROM MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP MANUAL FLUSH VALVE FROM MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP MANUAL FLUSH VALVE FROM MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP FLUSH VALVE FROM MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP FLUSH VALVE FROM MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP VALVE FROM MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP VALVE FROM MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP FROM MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP FROM MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP MOEN. MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP MODEL NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP NUMBER 8310M16. 1" INLET SUPPLY, 1-1/2" TOP 8310M16. 1" INLET SUPPLY, 1-1/2" TOP 8310M16. 1" INLET SUPPLY, 1-1/2" TOP 1" INLET SUPPLY, 1-1/2" TOP 1" INLET SUPPLY, 1-1/2" TOP INLET SUPPLY, 1-1/2" TOP INLET SUPPLY, 1-1/2" TOP SUPPLY, 1-1/2" TOP SUPPLY, 1-1/2" TOP 1-1/2" TOP 1-1/2" TOP TOP TOP SPUD. SELF-CLEANING FILTER. AMERICAN STANDARD #5905.100 TOILET SEAT, EXTRA HEAVY DUTY, FOR ELONGATED BOWL, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, SELF-CLEANING FILTER. AMERICAN STANDARD #5905.100 TOILET SEAT, EXTRA HEAVY DUTY, FOR ELONGATED BOWL, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, SELF-CLEANING FILTER. AMERICAN STANDARD #5905.100 TOILET SEAT, EXTRA HEAVY DUTY, FOR ELONGATED BOWL, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, FILTER. AMERICAN STANDARD #5905.100 TOILET SEAT, EXTRA HEAVY DUTY, FOR ELONGATED BOWL, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, FILTER. AMERICAN STANDARD #5905.100 TOILET SEAT, EXTRA HEAVY DUTY, FOR ELONGATED BOWL, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, AMERICAN STANDARD #5905.100 TOILET SEAT, EXTRA HEAVY DUTY, FOR ELONGATED BOWL, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, AMERICAN STANDARD #5905.100 TOILET SEAT, EXTRA HEAVY DUTY, FOR ELONGATED BOWL, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, STANDARD #5905.100 TOILET SEAT, EXTRA HEAVY DUTY, FOR ELONGATED BOWL, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, STANDARD #5905.100 TOILET SEAT, EXTRA HEAVY DUTY, FOR ELONGATED BOWL, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, #5905.100 TOILET SEAT, EXTRA HEAVY DUTY, FOR ELONGATED BOWL, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, #5905.100 TOILET SEAT, EXTRA HEAVY DUTY, FOR ELONGATED BOWL, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, TOILET SEAT, EXTRA HEAVY DUTY, FOR ELONGATED BOWL, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, TOILET SEAT, EXTRA HEAVY DUTY, FOR ELONGATED BOWL, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, SEAT, EXTRA HEAVY DUTY, FOR ELONGATED BOWL, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, SEAT, EXTRA HEAVY DUTY, FOR ELONGATED BOWL, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, EXTRA HEAVY DUTY, FOR ELONGATED BOWL, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, EXTRA HEAVY DUTY, FOR ELONGATED BOWL, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, HEAVY DUTY, FOR ELONGATED BOWL, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, HEAVY DUTY, FOR ELONGATED BOWL, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, DUTY, FOR ELONGATED BOWL, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, DUTY, FOR ELONGATED BOWL, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, FOR ELONGATED BOWL, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, FOR ELONGATED BOWL, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, ELONGATED BOWL, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, ELONGATED BOWL, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, BOWL, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, BOWL, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, FRONT, WHITE SOLID PLASTIC, WITH COVER, FRONT, WHITE SOLID PLASTIC, WITH COVER, WHITE SOLID PLASTIC, WITH COVER, WHITE SOLID PLASTIC, WITH COVER, SOLID PLASTIC, WITH COVER, SOLID PLASTIC, WITH COVER, PLASTIC, WITH COVER, PLASTIC, WITH COVER, WITH COVER, WITH COVER, COVER, COVER, STAINLESS STEEL CHECK HINGES, METAL FLAT WASHERS STAINLESS STEEL POSTS AND NUTS. WATTS #ISCA-101-M11, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, STEEL CHECK HINGES, METAL FLAT WASHERS STAINLESS STEEL POSTS AND NUTS. WATTS #ISCA-101-M11, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, STEEL CHECK HINGES, METAL FLAT WASHERS STAINLESS STEEL POSTS AND NUTS. WATTS #ISCA-101-M11, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, CHECK HINGES, METAL FLAT WASHERS STAINLESS STEEL POSTS AND NUTS. WATTS #ISCA-101-M11, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, CHECK HINGES, METAL FLAT WASHERS STAINLESS STEEL POSTS AND NUTS. WATTS #ISCA-101-M11, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, HINGES, METAL FLAT WASHERS STAINLESS STEEL POSTS AND NUTS. WATTS #ISCA-101-M11, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, HINGES, METAL FLAT WASHERS STAINLESS STEEL POSTS AND NUTS. WATTS #ISCA-101-M11, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, METAL FLAT WASHERS STAINLESS STEEL POSTS AND NUTS. WATTS #ISCA-101-M11, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, METAL FLAT WASHERS STAINLESS STEEL POSTS AND NUTS. WATTS #ISCA-101-M11, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, FLAT WASHERS STAINLESS STEEL POSTS AND NUTS. WATTS #ISCA-101-M11, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, FLAT WASHERS STAINLESS STEEL POSTS AND NUTS. WATTS #ISCA-101-M11, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, WASHERS STAINLESS STEEL POSTS AND NUTS. WATTS #ISCA-101-M11, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, WASHERS STAINLESS STEEL POSTS AND NUTS. WATTS #ISCA-101-M11, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, STAINLESS STEEL POSTS AND NUTS. WATTS #ISCA-101-M11, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, STAINLESS STEEL POSTS AND NUTS. WATTS #ISCA-101-M11, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, STEEL POSTS AND NUTS. WATTS #ISCA-101-M11, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, STEEL POSTS AND NUTS. WATTS #ISCA-101-M11, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, POSTS AND NUTS. WATTS #ISCA-101-M11, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, POSTS AND NUTS. WATTS #ISCA-101-M11, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, AND NUTS. WATTS #ISCA-101-M11, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, AND NUTS. WATTS #ISCA-101-M11, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, NUTS. WATTS #ISCA-101-M11, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, NUTS. WATTS #ISCA-101-M11, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, WATTS #ISCA-101-M11, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, WATTS #ISCA-101-M11, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, #ISCA-101-M11, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, #ISCA-101-M11, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, SINGLE HORIZONTAL, ADJUSTABLE TOILET CARRIER, HORIZONTAL, ADJUSTABLE TOILET CARRIER, HORIZONTAL, ADJUSTABLE TOILET CARRIER, ADJUSTABLE TOILET CARRIER, ADJUSTABLE TOILET CARRIER, TOILET CARRIER, TOILET CARRIER, CARRIER, CARRIER, MOUNTED ON CONCRETE FLOOR, ALL EPOXY COATED CAST IRON FITTING, ADJUSTABLE ABS SLIDE NIPPLE WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED ON CONCRETE FLOOR, ALL EPOXY COATED CAST IRON FITTING, ADJUSTABLE ABS SLIDE NIPPLE WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED ON CONCRETE FLOOR, ALL EPOXY COATED CAST IRON FITTING, ADJUSTABLE ABS SLIDE NIPPLE WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED CONCRETE FLOOR, ALL EPOXY COATED CAST IRON FITTING, ADJUSTABLE ABS SLIDE NIPPLE WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED CONCRETE FLOOR, ALL EPOXY COATED CAST IRON FITTING, ADJUSTABLE ABS SLIDE NIPPLE WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED FLOOR, ALL EPOXY COATED CAST IRON FITTING, ADJUSTABLE ABS SLIDE NIPPLE WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED FLOOR, ALL EPOXY COATED CAST IRON FITTING, ADJUSTABLE ABS SLIDE NIPPLE WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED ALL EPOXY COATED CAST IRON FITTING, ADJUSTABLE ABS SLIDE NIPPLE WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED ALL EPOXY COATED CAST IRON FITTING, ADJUSTABLE ABS SLIDE NIPPLE WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED EPOXY COATED CAST IRON FITTING, ADJUSTABLE ABS SLIDE NIPPLE WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED EPOXY COATED CAST IRON FITTING, ADJUSTABLE ABS SLIDE NIPPLE WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED COATED CAST IRON FITTING, ADJUSTABLE ABS SLIDE NIPPLE WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED COATED CAST IRON FITTING, ADJUSTABLE ABS SLIDE NIPPLE WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED CAST IRON FITTING, ADJUSTABLE ABS SLIDE NIPPLE WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED CAST IRON FITTING, ADJUSTABLE ABS SLIDE NIPPLE WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED IRON FITTING, ADJUSTABLE ABS SLIDE NIPPLE WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED IRON FITTING, ADJUSTABLE ABS SLIDE NIPPLE WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED FITTING, ADJUSTABLE ABS SLIDE NIPPLE WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED FITTING, ADJUSTABLE ABS SLIDE NIPPLE WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED ADJUSTABLE ABS SLIDE NIPPLE WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED ADJUSTABLE ABS SLIDE NIPPLE WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED ABS SLIDE NIPPLE WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED ABS SLIDE NIPPLE WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED SLIDE NIPPLE WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED SLIDE NIPPLE WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED NIPPLE WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED NIPPLE WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED WITH INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED INTEGRAL TEST CAP AND NEOPRENE BOWL GASKET, WASTED TEST CAP AND NEOPRENE BOWL GASKET, WASTED TEST CAP AND NEOPRENE BOWL GASKET, WASTED CAP AND NEOPRENE BOWL GASKET, WASTED CAP AND NEOPRENE BOWL GASKET, WASTED AND NEOPRENE BOWL GASKET, WASTED AND NEOPRENE BOWL GASKET, WASTED NEOPRENE BOWL GASKET, WASTED NEOPRENE BOWL GASKET, WASTED BOWL GASKET, WASTED BOWL GASKET, WASTED GASKET, WASTED GASKET, WASTED WASTED WASTED PLATED HARDWARE, CHROME CAP NUTS, TILING FRAME, 102 MM (4") NO HUB WASTE, 51 MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED HARDWARE, CHROME CAP NUTS, TILING FRAME, 102 MM (4") NO HUB WASTE, 51 MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED HARDWARE, CHROME CAP NUTS, TILING FRAME, 102 MM (4") NO HUB WASTE, 51 MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED CHROME CAP NUTS, TILING FRAME, 102 MM (4") NO HUB WASTE, 51 MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED CHROME CAP NUTS, TILING FRAME, 102 MM (4") NO HUB WASTE, 51 MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED CAP NUTS, TILING FRAME, 102 MM (4") NO HUB WASTE, 51 MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED CAP NUTS, TILING FRAME, 102 MM (4") NO HUB WASTE, 51 MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED NUTS, TILING FRAME, 102 MM (4") NO HUB WASTE, 51 MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED NUTS, TILING FRAME, 102 MM (4") NO HUB WASTE, 51 MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED TILING FRAME, 102 MM (4") NO HUB WASTE, 51 MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED TILING FRAME, 102 MM (4") NO HUB WASTE, 51 MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED FRAME, 102 MM (4") NO HUB WASTE, 51 MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED FRAME, 102 MM (4") NO HUB WASTE, 51 MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED 102 MM (4") NO HUB WASTE, 51 MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED 102 MM (4") NO HUB WASTE, 51 MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED MM (4") NO HUB WASTE, 51 MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED MM (4") NO HUB WASTE, 51 MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED (4") NO HUB WASTE, 51 MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED (4") NO HUB WASTE, 51 MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED NO HUB WASTE, 51 MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED NO HUB WASTE, 51 MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED HUB WASTE, 51 MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED HUB WASTE, 51 MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED WASTE, 51 MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED WASTE, 51 MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED 51 MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED 51 MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED MM (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED (2") NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED NO HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED HUB VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED VENT, 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED 158.8 KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED KG (350 LBS) STATIC LOAD. 305 MM (12") FINISHED (350 LBS) STATIC LOAD. 305 MM (12") FINISHED (350 LBS) STATIC LOAD. 305 MM (12") FINISHED LBS) STATIC LOAD. 305 MM (12") FINISHED LBS) STATIC LOAD. 305 MM (12") FINISHED STATIC LOAD. 305 MM (12") FINISHED STATIC LOAD. 305 MM (12") FINISHED LOAD. 305 MM (12") FINISHED LOAD. 305 MM (12") FINISHED 305 MM (12") FINISHED 305 MM (12") FINISHED MM (12") FINISHED MM (12") FINISHED (12") FINISHED (12") FINISHED FINISHED FINISHED METAL STUD WALL TO BACK OF PIPE SPACE. CARRIER SHALL BE FROM JAY R. SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET STUD WALL TO BACK OF PIPE SPACE. CARRIER SHALL BE FROM JAY R. SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET STUD WALL TO BACK OF PIPE SPACE. CARRIER SHALL BE FROM JAY R. SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET WALL TO BACK OF PIPE SPACE. CARRIER SHALL BE FROM JAY R. SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET WALL TO BACK OF PIPE SPACE. CARRIER SHALL BE FROM JAY R. SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET TO BACK OF PIPE SPACE. CARRIER SHALL BE FROM JAY R. SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET TO BACK OF PIPE SPACE. CARRIER SHALL BE FROM JAY R. SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET BACK OF PIPE SPACE. CARRIER SHALL BE FROM JAY R. SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET BACK OF PIPE SPACE. CARRIER SHALL BE FROM JAY R. SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET OF PIPE SPACE. CARRIER SHALL BE FROM JAY R. SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET OF PIPE SPACE. CARRIER SHALL BE FROM JAY R. SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET PIPE SPACE. CARRIER SHALL BE FROM JAY R. SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET PIPE SPACE. CARRIER SHALL BE FROM JAY R. SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET SPACE. CARRIER SHALL BE FROM JAY R. SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET SPACE. CARRIER SHALL BE FROM JAY R. SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET CARRIER SHALL BE FROM JAY R. SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET CARRIER SHALL BE FROM JAY R. SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET SHALL BE FROM JAY R. SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET SHALL BE FROM JAY R. SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET BE FROM JAY R. SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET BE FROM JAY R. SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET FROM JAY R. SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET FROM JAY R. SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET JAY R. SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET JAY R. SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET R. SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET R. SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET SMITH MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET MODEL NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET NUMBER 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET 0600 FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET FACE PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET PLATE FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET FIXTURE SUPPORT WITHOUT FITTINGS FOR SIPHON JET SUPPORT WITHOUT FITTINGS FOR SIPHON JET SUPPORT WITHOUT FITTINGS FOR SIPHON JET WITHOUT FITTINGS FOR SIPHON JET WITHOUT FITTINGS FOR SIPHON JET FITTINGS FOR SIPHON JET FITTINGS FOR SIPHON JET FOR SIPHON JET FOR SIPHON JET SIPHON JET SIPHON JET JET JET WATER CLOSET.
AutoCAD SHX Text
AMERICAN STANDARD/ #0373.950
AutoCAD SHX Text
STAINLESS STEEL HAND WASH SINK. TOP MOUNTED. 20" (510MM)L X 20-1/2" (520MM) W X 7" (180MM) D. 20 GAUGE STAINLESS STEEL. HIGH GLOSS FINISH. WASTE OUTLET DISMETER 3-1/2" (88MM). FAUCET SHALL BE FROM KINDRED REGINOX # KFPOS3000. SIDE LEVER WITH PULL OUT SPRAY AND STREAM. 1.8-GPM. LAWLER #TMM-1070, BELOW DECK MECHANICAL WATER MIXING VALVE, BRONZE BODY, TEMPERATURE ADJUSTING DIAL, 10 MM (3/8") INLETS AND OUTLET COMPRESSION FITTINGS, HIGH TEMPERATURE THERMOSTATIC LIMIT STOP, SHUT-OFF WITH AUTOMATIC RESET WHEN TEMPERATURE EXCEEDS 120 ºF (48.8 ºC), INTEGRAL CHECKS, OFFER TEMPERATURE RANGE FROM FULL COLD THROUGH 46 °C (114.8 °F). MCGUIRE #LFH170BV, FAUCET SUPPLIES, CHROME PLATED POLISHED BRASS, COMMERCIAL DUTY 1/4 TURN BALL VALVE ANGLE STOPS, 13 MM (1/2") I.D. INLET X 127 MM (5") HORIZONTAL EXTENSION TUBES, COMBINATION V.P. LOOSE KEY HANDLES, ESCUTCHEON AND FLEXIBLE COPPER RISERS. MCGUIRE #8912CB P-TRAP, HEAVY CAST BRASS ADJUSTABLE BODY, WITH SLIP NUT, 38 MM (1-1/2") SIZE, BOX FLANGE AND SEAMLESS TUBULAR WALL BEND.
AutoCAD SHX Text
HAND WASHING SINK
AutoCAD SHX Text
SK-1
AutoCAD SHX Text
KINDRED REGINOX/ RSL5251-1
AutoCAD SHX Text
SK-2
AutoCAD SHX Text
ELITE UNIVERSAL/ BS2424-3
AutoCAD SHX Text
THREE COMPARTMENT SINK
AutoCAD SHX Text
ELITE UNIVERSAL THREE COMPARTMENT SINK BS2424-3-72". THE UNIVERSAL BS2424-3 THREE COMPARTMENT COMMERCIAL SINK INCLUDES THREE SEPARATED 13 INCH DEEP BOWLS. MADE OF 18-GAUGE TYPE 304 STAINLESS STEEL. EACH BOWL IS 24"X24"X13" (600X600X325MM). FAUCET SHALL BE FROM ELITE UNIVERSAL, 16" LOW LEAD WALL MOUNT SWING SPOUT FAUCET-8 CENTERS. FAUCET SPOUT LENGTH IS 16" (400MM). 2 GPM FLOW RATE. MCGUIRE #8912CB P-TRAP, HEAVY CAST BRASS ADJUSTABLE BODY, WITH SLIP NUT, 38 MM (1-1/2") SIZE, BOX FLANGE AND SEAMLESS TUBULAR WALL BEND.
AutoCAD SHX Text
SK-3
AutoCAD SHX Text
KINDRED REGINOX/ RDL5279-1
AutoCAD SHX Text
TWO COMPARTMENT SINK
AutoCAD SHX Text
TWO COMPARTMENT SINK FROM KINDRED REGINOX. MODEL # RDL5279-1. 20 GAUGE STAINLESS STEEL WITH SINGLE FAUCET HOLE. EACH BOWL IS 14" X 16"X 7"(350MM X400MM X175MM). FAUCET SHALL BE FROM KINDRED EZ TORQUE KF10G COMMERCIAL. SIDE LEVER. FLOW RATE SHALL BE 1.75GPM. LAWLER #TMM-1070, BELOW DECK MECHANICAL WATER MIXING VALVE, BRONZE BODY, TEMPERATURE ADJUSTING DIAL, 10 MM (3/8") INLETS AND OUTLET COMPRESSION FITTINGS, HIGH TEMPERATURE THERMOSTATIC LIMIT STOP, SHUT-OFF WITH AUTOMATIC RESET WHEN TEMPERATURE EXCEEDS 120 ºF (48.8 ºC), INTEGRAL CHECKS, OFFER TEMPERATURE RANGE FROM FULL COLD THROUGH 46 °C (114.8 °F). MCGUIRE #LFH170BV, FAUCET SUPPLIES, CHROME PLATED POLISHED BRASS, COMMERCIAL DUTY 1/4 TURN BALL VALVE ANGLE STOPS, 13 MM (1/2") I.D. INLET X 127 MM (5") HORIZONTAL EXTENSION TUBES, COMBINATION V.P. LOOSE KEY HANDLES, ESCUTCHEON AND FLEXIBLE COPPER RISERS. MCGUIRE #8912CB P-TRAP, HEAVY CAST BRASS ADJUSTABLE BODY, WITH SLIP NUT, 38 MM (1-1/2") SIZE, BOX FLANGE AND SEAMLESS TUBULAR WALL BEND.
AutoCAD SHX Text
HB-SP
AutoCAD SHX Text
HOSE BIBB FOR SNOW PIT
AutoCAD SHX Text
WATTS-FEBCO/ FPHB-1
AutoCAD SHX Text
KEY OPERATED WALL HYDRANT. DRAINABLE FREEZELESS WALL HYDRANT SHALL BE INSTALLED OUTSIDE AS SHOWN, TO PROVIDE A MEANS OF SHUTTING OFF THE FLOW OF WATER DRAINABLE FREEZELESS WALL HYDRANT SHALL BE INSTALLED OUTSIDE AS SHOWN, TO PROVIDE A MEANS OF SHUTTING OFF THE FLOW OF WATER DRAINABLE FREEZELESS WALL HYDRANT SHALL BE INSTALLED OUTSIDE AS SHOWN, TO PROVIDE A MEANS OF SHUTTING OFF THE FLOW OF WATER TO THE IRRIGATION SYSTEM FOR WINTERIZING THE SYSTEM AND THE BACKFLOW PREVENTER. THE VALVE BODY AND SHAFT SHALL BE OF COPPER OR BRASS CONSTRUCTION WITH A ONE PIECE VALVE PLUNGER TO CONTROL BOTH FLOW AND DRAIN FUNCTIONS. THE HYDRANT SHALL BE DESIGNED TO INCLUDE A DRAIN PLUG FOR WINTERIZATION OF THE IRRIGATION SYSTEM AND BACKFLOW PREVENTER. THE HYDRANT SHALL BE TAMPER RESISTANT AND SHALL BE KEY OPERATED. THE HYDRANT SHALL BE 1" (25MM) SIZE AND OF THE PROPER LENGTH FOR THE INSTALLATION A.
AutoCAD SHX Text
NON-FREEZE HYDRANT, ECOLOTROL CERAMIC DISC WALL HYDRANT, ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH HYDRANT, ECOLOTROL CERAMIC DISC WALL HYDRANT, ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH HYDRANT, ECOLOTROL CERAMIC DISC WALL HYDRANT, ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH ECOLOTROL CERAMIC DISC WALL HYDRANT, ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH ECOLOTROL CERAMIC DISC WALL HYDRANT, ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH CERAMIC DISC WALL HYDRANT, ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH CERAMIC DISC WALL HYDRANT, ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH DISC WALL HYDRANT, ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH DISC WALL HYDRANT, ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH WALL HYDRANT, ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH WALL HYDRANT, ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH HYDRANT, ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH HYDRANT, ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH ENCASED, ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH ANTI-SIPHON C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH C/W BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH BACKFLOW PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH PREVENTER. PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH PROVIDE AND INSTALL ALL NECESSARY COMPLY WITH AND INSTALL ALL NECESSARY COMPLY WITH AND INSTALL ALL NECESSARY COMPLY WITH INSTALL ALL NECESSARY COMPLY WITH INSTALL ALL NECESSARY COMPLY WITH ALL NECESSARY COMPLY WITH ALL NECESSARY COMPLY WITH NECESSARY COMPLY WITH NECESSARY COMPLY WITH COMPLY WITH COMPLY WITH WITH WITH MANUFACTURER'S RECOMMENDATION KITS.
AutoCAD SHX Text
ZURN/Z1320
AutoCAD SHX Text
WALL0HUNG SINK, VITREOUS CHINA. REAR OVERFLOW. FAUCET HOLES ON 102MM CENTERS. FAUCET SHALL BE FROM MOEN. M-DURA CHROME TWO-HANDLE LAVATORY FAUCET #8278SMF12. BRASS SPOUT AND METAL HANDLE CONSTRUCTION WITH CHROME PLATED FINISH. 1/2" IPS CONNECTIONS. 4" CENTER REST. VANDAL RESISTANT TORX HEAD SCREWS. VANDAL RESISTANT LAMINAR FLOW AERATOR LIMITED TO 5.7L/M. KNEE GUARD IS NOT REQUIRED. MCGUIRE #155A OPEN GRID DRAIN, CAST BRASS ONE PIECE TOP, 17 GA. (1.5 MM) TUBULAR 32 MM (1-1/4") TAILPIECE. MCGUIRE #LFH170BVRB, FAUCET SUPPLIES, CHROME PLATED POLISHED BRASS, COMMERCIAL DUTY 1/4 TURN BALL VALVE ANGLE STOPS, 13 MM (1/2") I.D. INLET X 127 MM (5") HORIZONTAL EXTENSION TUBES, COMBINATION V.P. LOOSE KEY HANDLES, ESCUTCHEON AND STAINLESS STEEL BRAIDED FLEXIBLE RISERS. MCGUIRE #8872C P-TRAP, HEAVY CAST BRASS ADJUSTABLE BODY, WITH SLIP NUT, 32 MM (1-1/4") SIZE, SHALLOW WALL FLANGE AND SEAMLESS TUBULAR WALL BEND. WATTS #WCA-411-CA-481, BASIN CARRIER, CONCEALED ARMS, WALL FLANGES TO ATTACH TO BACKING PLATE SECURED IN WALL WITH LOCKING DEVICE AND LEVELLING SCREWS, HEAVY GAUGE STEEL UPRIGHTS WITH INTEGRAL WELDED FEET.
AutoCAD SHX Text
AMERICAN STANDARD/ #0954.123EC
AutoCAD SHX Text
TYPICAL FOR 2
AutoCAD SHX Text
TYPICAL FOR 4
AutoCAD SHX Text
MS
AutoCAD SHX Text
MOP SINK
AutoCAD SHX Text
FAUCET SHALL BE FROM ELITE UNIVERSAL: #MFC-8W-MOP SINK FAUCET 8". CONSTRUCTED OUT OF STEEL, ONE-PIECE SEAM LESS FAUCET UNIT WITH HOT AND COLD NOB.PROVIDE P-TRAP, SAME MATERIAL AS THE CONNECTING PIPE DRAIN. PROVIDE NECESSARY ACCESSORIES TO COMPLETE THE INSTALLATION.
AutoCAD SHX Text
ELITE UNIVERSAL/ MPS252110-25" FLOOR SINK
AutoCAD SHX Text
MECHANICAL SCHEDULE-2
AutoCAD SHX Text
M6.2
AutoCAD SHX Text
PH.: (905) 946 4260 FAX: (905) 946 0901
AutoCAD SHX Text
MARKHAM ONTARIO L3R 1A3
AutoCAD SHX Text
UNIT 229
AutoCAD SHX Text
7181 WOODBINE AVE
AutoCAD SHX Text
%%UTHOMAS A. FEKETE LIMITED

Air System Sizing Summary for GENERAL AREA

Zone Sizing Summary for GENERAL AREA

Air System Design Load Summary for GENERAL AREA

Ventilation Sizing Summary for GENERAL AREA

Zone Sizing Summary for KITCHEN

Air System Sizing Summary for KITCHEN

Ventilation Sizing Summary for KITCHEN

Air System Design Load Summary for KITCHEN

Design Weather Parameters

GAS CONSUMPTION CALCULATION

FRESH AIR BALANCING CALCULATION

DATE INITIALREVISIONSNo.

DESIGN

DATE:

DRAWNCHECKED

DRAWING NUMBER

SIGNED

SCALE: CONTRACT No.

2019-11-01 ISSUED FOR 60% CONSTRUCTION DOCUMENTS1

WS2492514132

CITY ASSET No. 297

DUFFERIN GROVE PARK NORTH-WEST CORNER

AND CLUBHOUSE IMPROVEMENTS

DR

AW

IN

G P

RIN

T D

AT

E: 7/10/2020 5:04:32 P

M

FIL

EN

AM

E: \\T

AF

_S

ER

VE

R\taf_m

ain

\P

ro

jects\C

urren

t P

ro

jects\18173 D

UF

FE

RIN

G

RO

VE

P

AR

K IM

PR

OV

EM

EN

TS

\300 D

esig

n\301 M

E D

wg

s\18173 M

EC

H\18173

m m

etric.d

wg

YA YA BZ

JOB NUMBER: 18173

2020-01-17 ISSUED FOR 90% COORDINATION2

2020-02-14 PROGRESS SET3

2020-03-06 ISSUED FOR PERMIT4

2020-03-06

2020-03-24 ISSUED FOR CD'S5

2020-06-12

2020-06-12 ISSUED FOR TENDER6

AutoCAD SHX Text
MECHANICAL LOAD CALCULATION
AutoCAD SHX Text
M7
AutoCAD SHX Text
PH.: (905) 946 4260 FAX: (905) 946 0901
AutoCAD SHX Text
MARKHAM ONTARIO L3R 1A3
AutoCAD SHX Text
UNIT 229
AutoCAD SHX Text
7181 WOODBINE AVE
AutoCAD SHX Text
%%UTHOMAS A. FEKETE LIMITED

GAS FIRED HOT WATER TANK (FLOOR MOUNTED)

DUCT HANGER DETAIL SQUARE DIFFUSER MOUNTING DETAIL

9

"

L

L

DETAIL OF DUCTWORK BRANCH

TRANSFER AIR DUCT DETIAL

ROUND DIFFUSER MOUNTING DETAIL (OPENING CEILING)

TRAP PRIMER DETAIL

SQUARE DUCT GRILLE MOUNTING DETAIL

HOT WATER HEATER COMBUSTION/VENTILATION TERMINATION KIT

HOT WATER HEATER COMBUSTION/VENTILATION TERMINATION KIT

VENT THROUGH ROOF DETAIL

RPBA DETAILGAS CONNECTION FOR UNIT HEATERS

DATE INITIALREVISIONSNo.

DESIGN

DATE:

DRAWNCHECKED

DRAWING NUMBER

SIGNED

SCALE: CONTRACT No.

2019-11-01 ISSUED FOR 60% CONSTRUCTION DOCUMENTS1

WS2492514132

CITY ASSET No. 297

DUFFERIN GROVE PARK NORTH-WEST CORNER

AND CLUBHOUSE IMPROVEMENTS

DR

AW

IN

G P

RIN

T D

AT

E: 7/10/2020 5:04:38 P

M

FIL

EN

AM

E: \\T

AF

_S

ER

VE

R\taf_m

ain

\P

ro

jects\C

urren

t P

ro

jects\18173 D

UF

FE

RIN

G

RO

VE

P

AR

K IM

PR

OV

EM

EN

TS

\300 D

esig

n\301 M

E D

wg

s\18173 M

EC

H\18173

m m

etric.d

wg

YA YA BZ

JOB NUMBER: 18173

2020-01-17 ISSUED FOR 90% COORDINATION2

2020-02-14 PROGRESS SET3

2020-03-06 ISSUED FOR PERMIT4

2020-03-06

2020-03-24 ISSUED FOR CD'S5

2020-06-12

2020-06-12 ISSUED FOR TENDER6

AutoCAD SHX Text
7
AutoCAD SHX Text
SCALE : N.T.S.
AutoCAD SHX Text
3/8" BOLT, NUT &
AutoCAD SHX Text
1"X16 GA CONTINUOS
AutoCAD SHX Text
COLLAR DRAWN TIGHT
AutoCAD SHX Text
%%URECTANGULAR DUCT HANGER
AutoCAD SHX Text
2. ATTACHMENTS TO OVERHEAD STRUCTURE SHALL BE MADE IN ACCORDANCE WITH STRUCTURAL ENGINEERS
AutoCAD SHX Text
REQUIREMENTS AND WEIGHT LIMITATIONS. ALL ATTACHMENT METHODS TO STRUCTURE SHALL BE SUBMITTED
AutoCAD SHX Text
3. PROVIDE SWAY AND SEISMIC BRACING FOR TWICE THE CODE REQUIREMENTS (WHERE REQUIRED).
AutoCAD SHX Text
1. REFER TO SPECIFICATIONS FOR HANGER SPACINGS.
AutoCAD SHX Text
TO STRUCTURAL ENGINEER FOR REVIEW.
AutoCAD SHX Text
%%UNOTES:
AutoCAD SHX Text
50" MAX.
AutoCAD SHX Text
(TYP.)
AutoCAD SHX Text
%%UROUND DUCT HANGER
AutoCAD SHX Text
1" X 16 GA.
AutoCAD SHX Text
HANGER STRAP (TYP.)
AutoCAD SHX Text
SHEET METAL
AutoCAD SHX Text
SCREWS
AutoCAD SHX Text
AROUND DUCT
AutoCAD SHX Text
2" MAX.
AutoCAD SHX Text
(FOR DUCTS 24"%%C AND SMALLER)
AutoCAD SHX Text
STAR WASHER
AutoCAD SHX Text
TO FORM A GOOD SEAL
AutoCAD SHX Text
MTL. TAPE INSULATION TO DUCT
AutoCAD SHX Text
DUCT INSULATION & VINYL TO SHT.
AutoCAD SHX Text
TAPE. STRAP CLAMP OVER FLEX
AutoCAD SHX Text
DUCT TO SHT. MTL. W/ MIN. OF
AutoCAD SHX Text
SECURELY TAPE VINYL FLEX
AutoCAD SHX Text
(2) CONTINUOUS WRAPS OF DUCT
AutoCAD SHX Text
THERMAL INSULATING BLANKET
AutoCAD SHX Text
CEILINGS ONLY.
AutoCAD SHX Text
REQUIRED FOR FIRE RATED
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
ALL DIFFUSERS ARE 4-WAY BLOW
AutoCAD SHX Text
UNLESS NOTED OTHERWISE.
AutoCAD SHX Text
TRANSITION AS REQUIRED
AutoCAD SHX Text
SUPPLY AIR DIFFUSER
AutoCAD SHX Text
MAX. 1200mm.)
AutoCAD SHX Text
CONNECTION. (MIN. 1000mm,
AutoCAD SHX Text
INSULATED FLEXIBLE
AutoCAD SHX Text
INSULATED
AutoCAD SHX Text
TO S.A. MAIN
AutoCAD SHX Text
ROUND DUCT
AutoCAD SHX Text
SHT. MTL. ELBOW REQUIRED
AutoCAD SHX Text
SQ. ELBOW WITH SINGLE
AutoCAD SHX Text
THICKNESS VANES
AutoCAD SHX Text
3 1/4"
AutoCAD SHX Text
SQ. ELBOW WITH TYPE "A"
AutoCAD SHX Text
DOUBLE THICKNESS VANES
AutoCAD SHX Text
1 1/2"
AutoCAD SHX Text
R=2"
AutoCAD SHX Text
B
AutoCAD SHX Text
D
AutoCAD SHX Text
45%%d
AutoCAD SHX Text
F
AutoCAD SHX Text
C
AutoCAD SHX Text
45°
AutoCAD SHX Text
RECTANGULAR DUCT
AutoCAD SHX Text
RECTANGULAR
AutoCAD SHX Text
CONICAL FITTING SEAL AIRTIGHT W/MASTIC
AutoCAD SHX Text
ROUND
AutoCAD SHX Text
MAIN DUCT
AutoCAD SHX Text
AIR FLOW 45°SADDLE TAP
AutoCAD SHX Text
AIR FLOW
AutoCAD SHX Text
AIR FLOW
AutoCAD SHX Text
ROUND TO ROUND
AutoCAD SHX Text
RECTANGULAR TO RECTANGULAR
AutoCAD SHX Text
RECTANGULAR TO ROUND
AutoCAD SHX Text
RECTANGULAR TO ROUND
AutoCAD SHX Text
- MAX. 30° (EXCEPT 45°IS PERMITTED AT ROUND TO FLAT OVAL)
AutoCAD SHX Text
- MAX. 45° DIVERGING,60° CONVERGING
AutoCAD SHX Text
A
AutoCAD SHX Text
CONCENTRIC TRANSITION
AutoCAD SHX Text
E
AutoCAD SHX Text
ECCENTRIC TRANSITION
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
BRANCH
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
G
AutoCAD SHX Text
TURNING VANE DETAIL
AutoCAD SHX Text
DUCT SIZE 36"X36" OR UNDER
AutoCAD SHX Text
DUCT SIZE OVER 36"X36"
AutoCAD SHX Text
PLATE SAME GAUGE AS DUCT
AutoCAD SHX Text
USE GALVANIZED VANES FOR GALVANIZED OR ALUMINUM DUCTS
AutoCAD SHX Text
VANES PRE-ASSEMBLED ON RUNNER PLATES
AutoCAD SHX Text
1
AutoCAD SHX Text
SCALE : N.T.S.
AutoCAD SHX Text
4
AutoCAD SHX Text
SCALE : N.T.S.
AutoCAD SHX Text
3
AutoCAD SHX Text
SCALE : N.T.S.
AutoCAD SHX Text
2
AutoCAD SHX Text
SCALE : N.T.S.
AutoCAD SHX Text
CEILING SPACE.
AutoCAD SHX Text
TRANSFER DUCT IN
AutoCAD SHX Text
RIGID OPEN END
AutoCAD SHX Text
(SILICON FOAM)
AutoCAD SHX Text
WITH MASTIC
AutoCAD SHX Text
SEAL AROUND DUCT
AutoCAD SHX Text
SCREWED TO PARTION
AutoCAD SHX Text
TRIMMING ANGLE AND SLEEVE
AutoCAD SHX Text
GALVANIZED SHEET METAL
AutoCAD SHX Text
PROVIDE 22 (0.76 MM) GAUGE
AutoCAD SHX Text
OF SLAB
AutoCAD SHX Text
UNDERSIDE
AutoCAD SHX Text
PARTITION TO
AutoCAD SHX Text
GRILLE
AutoCAD SHX Text
DRYWALL CEILING
AutoCAD SHX Text
OPEN CEILING
AutoCAD SHX Text
5
AutoCAD SHX Text
SCALE : N.T.S.
AutoCAD SHX Text
6
AutoCAD SHX Text
SUPPLY AIR DIFFUSER
AutoCAD SHX Text
DUCTWORK
AutoCAD SHX Text
WHERE SPECIFIED, SUPPLY AIR DIFFUSERS TO BE PROVIDED WITH WITH E.H. PRICE MODEL VCR-7 OPPOSED BLADE DAMPER.
AutoCAD SHX Text
NOTE: ALL DIFFUSERS ARE 4-WAY BLOW. UNLESS NOTED OTHERWISE.
AutoCAD SHX Text
TRANSITION AS REQUIRED
AutoCAD SHX Text
FROM S.A. MAIN
AutoCAD SHX Text
SCALE : N.T.S.
AutoCAD SHX Text
ROUND RIGID DUCT
AutoCAD SHX Text
8
AutoCAD SHX Text
SCALE : N.T.S.
AutoCAD SHX Text
RUN IN PIPE
AutoCAD SHX Text
TO HORIZONTAL
AutoCAD SHX Text
300MM MINIMUM
AutoCAD SHX Text
FLOOR DRAIN
AutoCAD SHX Text
CONNECT TO
AutoCAD SHX Text
FLOOR DRAIN
AutoCAD SHX Text
13
AutoCAD SHX Text
13 COLD WATER
AutoCAD SHX Text
SUPPLY CONNECTION
AutoCAD SHX Text
AUTOMATIC
AutoCAD SHX Text
TRAP PRIMER
AutoCAD SHX Text
METAL CABINET
AutoCAD SHX Text
VALVE
AutoCAD SHX Text
SOLENOID
AutoCAD SHX Text
TRAP WATER LEVEL
AutoCAD SHX Text
BY TENANT
AutoCAD SHX Text
CONTRACTOR
AutoCAD SHX Text
BY LANDLORD
AutoCAD SHX Text
SUPPLY GRILLE OR DIFFUSER SECURED TO DUCT COLLAR
AutoCAD SHX Text
DAMPER
AutoCAD SHX Text
SUPPLY GRILLE
AutoCAD SHX Text
OPPOSED BLADE
AutoCAD SHX Text
AIR FLOW
AutoCAD SHX Text
45°
AutoCAD SHX Text
INTAKE AIR
AutoCAD SHX Text
EXHAUST AIR
AutoCAD SHX Text
INTAKE AIR
AutoCAD SHX Text
INTAKE AIR
AutoCAD SHX Text
2 x 1 1/2" (51x38mm)
AutoCAD SHX Text
REDUCER BUSHING
AutoCAD SHX Text
TERMINATION ASSEMBLY
AutoCAD SHX Text
CLAMP
AutoCAD SHX Text
OUTSIDE WALL
AutoCAD SHX Text
GRADE
AutoCAD SHX Text
MINIMUM 12" (305mm)
AutoCAD SHX Text
ABOBE GRADE
AutoCAD SHX Text
ELBOW
AutoCAD SHX Text
10 1/2" (267mm)
AutoCAD SHX Text
(BY TERMINATION KIT SUPPLIER)
AutoCAD SHX Text
(BY TERMINATION KIT SUPPLIER)
AutoCAD SHX Text
(BY TERMINATION KIT SUPPLIER)
AutoCAD SHX Text
(BY TERMINATION KIT SUPPLIER)
AutoCAD SHX Text
INTAKE AIR
AutoCAD SHX Text
INTAKE AIR
AutoCAD SHX Text
EXHAUST AIR
AutoCAD SHX Text
EXHAUST AIR
AutoCAD SHX Text
INTAKE AIR
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
SHEET METAL STRAP BY MECHANICAL CONTRACTOR (Clamp and sheet metal strap must be field installed to support the weight of the termination (kit)
AutoCAD SHX Text
12" (305mm) MINIMUM ABOVE AVERAGE SNOW ACCUMULATION
AutoCAD SHX Text
FLASHING (by termination kit supplier)
AutoCAD SHX Text
TERMINATION ASSEMBLY (by termination kit supplier)
AutoCAD SHX Text
CLAMP (by termination kit supplier)
AutoCAD SHX Text
REDUCER BUSHING (by termination kit supplier)
AutoCAD SHX Text
ELBOW (by termination kit supplier)
AutoCAD SHX Text
9
AutoCAD SHX Text
SCALE : N.T.S.
AutoCAD SHX Text
10
AutoCAD SHX Text
SCALE : N.T.S.
AutoCAD SHX Text
URETHANE INSULATION PREMOLDED TO INNER SIDE OF SLEEVE
AutoCAD SHX Text
THALER METAL INDUSTRIES
AutoCAD SHX Text
4"
AutoCAD SHX Text
(102mm)
AutoCAD SHX Text
REMOVABLE CAP
AutoCAD SHX Text
THALER REMOVABLE CAP STACK JACK FLASHING (ALUMINUM, COPPER OR STAINLESS STEEL) CAN BE CUT TO SUIT STACK HEIGHT
AutoCAD SHX Text
EMBED DECK FLANGE IN LAYER OF PLASTIC CEMENT
AutoCAD SHX Text
VENT PIPE
AutoCAD SHX Text
13 or 18"
AutoCAD SHX Text
(330 or 457mm)
AutoCAD SHX Text
11
AutoCAD SHX Text
SCALE : N.T.S.
AutoCAD SHX Text
750MM-1500MM AFF
AutoCAD SHX Text
FFD
AutoCAD SHX Text
WATER MAIN
AutoCAD SHX Text
1. MOUNTING HEIGHT: MOUNTED AT MOUNTING HEIGHT: MOUNTED AT 750MM-1500MM AFF. 2. CLEARANCE: ASSEMBLY TO BE READILY CLEARANCE: ASSEMBLY TO BE READILY ACCESSIBLE (NOT IN WALL OR CABINET) WITH 750MM CLEAR IN FRONT, 300MM CLEAR ON TOP AND 20MM CLEAR BEHIND. 3. RPBA TO BE DRAINED BY AN INDIRECT RPBA TO BE DRAINED BY AN INDIRECT STANDPIPE DRAIN. 40MM AIR GAP AND AIR BREAK 25MM ABOVE THE FUNNEL FLOOR DRAIN FLOOD LEVEL RIM.
AutoCAD SHX Text
<300 MM CLEARANCE ABOVE
AutoCAD SHX Text
25MM
AutoCAD SHX Text
12
AutoCAD SHX Text
SCALE : N.T.S.
AutoCAD SHX Text
DRIP LEG
AutoCAD SHX Text
UNION
AutoCAD SHX Text
GAS FIRED HEATER
AutoCAD SHX Text
ISOLATION GAS VALVE
AutoCAD SHX Text
GAS SUPPLY PIPING, SIZE AS NOTED ON PLAN
AutoCAD SHX Text
GAS CONNECTION
AutoCAD SHX Text
G
AutoCAD SHX Text
22
AutoCAD SHX Text
SCALE : N.T.S.
AutoCAD SHX Text
NOTE: THE VENT PIPE AT THE ZAMBONI GARAGE SHALL BE TALLER THAN PARAPET
AutoCAD SHX Text
T
AutoCAD SHX Text
PRV
AutoCAD SHX Text
DRAIN VALVE PIPE TO DRAIN (TYP)
AutoCAD SHX Text
PIPE TO DRAIN (TYP)
AutoCAD SHX Text
G
AutoCAD SHX Text
GAS FIRED DOMESTIC HOT WATER TANK (FLOOR MOUNTED)
AutoCAD SHX Text
DCW, DHW & DHWR PIPES IN CEILING SPACE
AutoCAD SHX Text
DHWR
AutoCAD SHX Text
COMBUSTION AIR INTAKE & VENT (PER OBC)
AutoCAD SHX Text
CONCRETE BASE BY MECH. CONTRACTOR
AutoCAD SHX Text
T
AutoCAD SHX Text
DHW
AutoCAD SHX Text
DCW
AutoCAD SHX Text
DCW
AutoCAD SHX Text
DCW
AutoCAD SHX Text
DHW
AutoCAD SHX Text
DHWR
AutoCAD SHX Text
THERMOSTATIC MIXING VALVE LAWLER SERIES 805
AutoCAD SHX Text
T
AutoCAD SHX Text
MECHANICAL DETAIL-1
AutoCAD SHX Text
M8.1
AutoCAD SHX Text
PH.: (905) 946 4260 FAX: (905) 946 0901
AutoCAD SHX Text
MARKHAM ONTARIO L3R 1A3
AutoCAD SHX Text
UNIT 229
AutoCAD SHX Text
7181 WOODBINE AVE
AutoCAD SHX Text
%%UTHOMAS A. FEKETE LIMITED

GAS PIPE ON ROOF INSTALLATION DETAIL

ROOFTOP GOOSENECK INSTALLATION DETIAL

ROOFTOP UNIT MOUNTING DETAIL

HUB DRAIN DETAIL

ROOF CURB DETAIL

WATER METER INSTALLATION DETAIL ROOF DRAIN DETAIL

ROOF EXHAUST DETAIL

SEMI-RECESS MOUNTED GREASE INTERCEPTOR DETAIL

DATE INITIALREVISIONSNo.

DESIGN

DATE:

DRAWNCHECKED

DRAWING NUMBER

SIGNED

SCALE: CONTRACT No.

2019-11-01 ISSUED FOR 60% CONSTRUCTION DOCUMENTS1

WS2492514132

CITY ASSET No. 297

DUFFERIN GROVE PARK NORTH-WEST CORNER

AND CLUBHOUSE IMPROVEMENTS

DR

AW

IN

G P

RIN

T D

AT

E: 7/10/2020 5:04:43 P

M

FIL

EN

AM

E: \\T

AF

_S

ER

VE

R\taf_m

ain

\P

ro

jects\C

urren

t P

ro

jects\18173 D

UF

FE

RIN

G

RO

VE

P

AR

K IM

PR

OV

EM

EN

TS

\300 D

esig

n\301 M

E D

wg

s\18173 M

EC

H\18173

m m

etric.d

wg

YA YA BZ

JOB NUMBER: 18173

2020-01-17 ISSUED FOR 90% COORDINATION2

2020-02-14 PROGRESS SET3

2020-03-06 ISSUED FOR PERMIT4

2020-03-06

2020-03-24 ISSUED FOR CD'S5

2020-06-12

2020-06-12 ISSUED FOR TENDER6

AutoCAD SHX Text
%%uNOTES:
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
G
AutoCAD SHX Text
F
AutoCAD SHX Text
E
AutoCAD SHX Text
D
AutoCAD SHX Text
C
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
%%uFRONT VIEW
AutoCAD SHX Text
%%uSIDE VIEW
AutoCAD SHX Text
G
AutoCAD SHX Text
F
AutoCAD SHX Text
E
AutoCAD SHX Text
D
AutoCAD SHX Text
C
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
F
AutoCAD SHX Text
E
AutoCAD SHX Text
G
AutoCAD SHX Text
D
AutoCAD SHX Text
C
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
ARTICLE SUPPLIED BY THE GENERAL CONTRACTOR ANDINSTALLED BY THE MECHANICAL CONTRACTOR
AutoCAD SHX Text
24"x24"x1" (610x610x25 MM) THICK BLUE COLOUR STYROFOAM INSULATION PLACED ON FINISHED ROOF
AutoCAD SHX Text
24"x24"x1/4" (610x610x6.5 MM) OUTDOOR USE TYPE CREOSOTED PLYWOOD
AutoCAD SHX Text
2" (50 MM) H * 8" (200 MM) W * 18" (460 MM) LONG CREOSOTED CEDAR PLANK
AutoCAD SHX Text
4" (100 MM) H * 4" (100 MM) W * 18" (460 MM) LONG CREOSOTED CEDAR BLOCK
AutoCAD SHX Text
ARTICLES SUPPLIED AND INSTALLED BY THE MECHANICA CONTRACTOR
AutoCAD SHX Text
GAS PIPE, ASTM A-53 SCHEDULE 40 PIPE
AutoCAD SHX Text
GRINNEL MODEL 262 WROUGHT IRON. OVERSIZE STRAPS TO ALLOW FOR PIPE MOVEMENT
AutoCAD SHX Text
CADIUM PLATED NO. 14, 2" (50 MM) LONG WOOD SCREWS
AutoCAD SHX Text
BOND TOGETHER WITH GALVANIZED NAIL
AutoCAD SHX Text
1. FOR 1" (25 MM) DIA. PIPE, PIPE SUPPORTS TO BE 7'-0" (2.13 M) APART AND FOR 1 1/4" (32 MM) PIPE FOR 1" (25 MM) DIA. PIPE, PIPE SUPPORTS TO BE 7'-0" (2.13 M) APART AND FOR 1 1/4" (32 MM) PIPE DIA. AND OVER TO BE 9'-0" (2.75 M) APART. PROVIDE SUPPORTS WITHIN 2'-0" (0.61 M) FROM BENDS AND TAKE-OFFS. 2. ALL GAS PIPING AND STRAPS TO BE PAINTED WITH NON-CORROSIVE. YELLOW PAINT TO GAS COMPANY'S ALL GAS PIPING AND STRAPS TO BE PAINTED WITH NON-CORROSIVE. YELLOW PAINT TO GAS COMPANY'S REQUIREMENTS. 3. PROVIDE SWING JOINTS ON ALL GAS PIPING TAKE-OFFSPROVIDE SWING JOINTS ON ALL GAS PIPING TAKE-OFFS
AutoCAD SHX Text
13
AutoCAD SHX Text
SCALE : N.T.S.
AutoCAD SHX Text
COUNTER FLASHING
AutoCAD SHX Text
BY THIS DIVISION
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
150 MIN. RADIUS
AutoCAD SHX Text
2/2 BIRD SCREEN
AutoCAD SHX Text
12"
AutoCAD SHX Text
600 MIN.
AutoCAD SHX Text
FLASHED, CURBED OPENING
AutoCAD SHX Text
BY OTHER DIVISION
AutoCAD SHX Text
DUCT SHALL BE LINED WITH 1" ACOUSTIC INSULATION APPLIED AS SPECIFIED. SEAL ALL SHEET METAL JOINTS AND MAKE WATER -TIGHT WITH HIGH VELOCITY DUCT SEALER
AutoCAD SHX Text
14
AutoCAD SHX Text
SCALE : N.T.S.
AutoCAD SHX Text
TO 'P' TRAP
AutoCAD SHX Text
DRAIN PIPE
AutoCAD SHX Text
3" OR 4"
AutoCAD SHX Text
FINISHED
AutoCAD SHX Text
FLOOR
AutoCAD SHX Text
OPEN HUB DRAIN
AutoCAD SHX Text
3" OR 4"
AutoCAD SHX Text
1"
AutoCAD SHX Text
M
AutoCAD SHX Text
~
AutoCAD SHX Text
~
AutoCAD SHX Text
~
AutoCAD SHX Text
TO DRAIN
AutoCAD SHX Text
FROM EXISTING DCW
AutoCAD SHX Text
TO SERVICE
AutoCAD SHX Text
BACKFLOW PREVENTOR TO COMPLY WITH CSA AND LOCAL CODE REQUIREMENTS (BFP-M)
AutoCAD SHX Text
2" (50 mm) WATER METER, NEPTUNE MODEL NO. T10, C/W REMOTE READOUT TO BE INSTALLED IN MECHANICAL ROOM
AutoCAD SHX Text
CHECK LOCAL CODE FOR APPROVED WATER METER.
AutoCAD SHX Text
UNDER DECK CLAMP
AutoCAD SHX Text
COMBINED FLASHING COLLAR AND GRAVEL STOP
AutoCAD SHX Text
TYPICAL ROOF CONSTRUCTION
AutoCAD SHX Text
ROOF DRAIN RUN IN TIGHT LINE, CONNECTION TO STORM WATER SYSTEM (SEE MECHANICAL DRAWING FOR SIZE AND LOCATION
AutoCAD SHX Text
24" SQ 4 Lbs LEAD FLASHING SET ON ROOF FELTS. PRIME TOP SURFACE BEFORE STRIPPING
AutoCAD SHX Text
EXTEND STRIPPING FELT 4" MIN. BEYOND EDGE OF HEAD FLASHING
AutoCAD SHX Text
CLAMPING RING OVER LEAD FLASHING AND MEMBRANE PLIES
AutoCAD SHX Text
INSULATION BY MECHANICAL CONTRACTOR
AutoCAD SHX Text
NOTE: ROOF DRAIN MUST BE RECCESSED INTO ROOF.
AutoCAD SHX Text
COUNTER FLASHING (BY MECHANICAL)
AutoCAD SHX Text
ROOF CURB SUPPLIED WITH A/C UNIT PROVIDE INSULATION ON CURB
AutoCAD SHX Text
PACK SPACE WITH FIBER GLASS INSULATION
AutoCAD SHX Text
CANT STRIP & FLASHING (BY MECHANICAL)
AutoCAD SHX Text
ROOF MATERIAL
AutoCAD SHX Text
RIGID INSULATION
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
UNIT SIZE SA & RA DUCTS
AutoCAD SHX Text
R/A
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
S/A
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
FC
AutoCAD SHX Text
FLEXIBLE CONNECTION
AutoCAD SHX Text
ROOFTOP UNIT
AutoCAD SHX Text
12mm THICK CONTINUOUS NEOPRENE GASKET
AutoCAD SHX Text
MEMBRANE MUST BE FULLY BONDED TO CURB AND EXTEND ABOVE FAN BASE FASTENERS (NOT BY DIVISION 15)
AutoCAD SHX Text
PRE-FINISHED EXHAUST FAN BASE. PROVIDE CONTINUOUS GASKET BETWEEN FAN BASE AND CURB AND SECURE FAN WITH FASTENERS SPACED MAX. 300mm ON CENTRE. SEAL JUNCTION OF BASE FLASHING AND CURB WITH HIGH GRADE SILICONE SEALANT.
AutoCAD SHX Text
PRE-MANUFACTURED CURB SECURED TO ROOF WITH GASKETTED FASTENERS MAX. 300mm ON CENTRE
AutoCAD SHX Text
EXTEND ROOF MEMBRANE OVER CURB FASTENERS (NOT BY DIVISION 15)
AutoCAD SHX Text
FINISHED ROOF. REFER TO ARCH. DRAWINGS FOR COMPOSITE DETAILS
AutoCAD SHX Text
REFER TO CURB DETAIL FOR MORE INFORMATION REGARDING CURB ASSEMBLY.
AutoCAD SHX Text
ROOF MOUNTED EXHAUST FAN
AutoCAD SHX Text
ROOF CURB PROVIDED BY MECHANICAL CONTRACTOR
AutoCAD SHX Text
FINISHED ROOF. REFER TO ARCH. DRAWINGS FOR DETAILS
AutoCAD SHX Text
STRUCTURAL STEEL FRAMING (NOT BY DIVISION 15)
AutoCAD SHX Text
EXTERNAL INSULATION TO EXTEND FROM UNDERSIDE OF ROOF STRUCTURE TO M.O.D.
AutoCAD SHX Text
MOTOR OPERATED DAMPER
AutoCAD SHX Text
EXHAUST DUCT
AutoCAD SHX Text
REFER TO CURB DETAIL FOR MORE INFORMATION REGARDING CURB ASSEMBLY.
AutoCAD SHX Text
NOTE: CURB HEIGHT SHALL BE DECIDED BASED ON LOCAL SNOW CONDITION
AutoCAD SHX Text
GREASE GUARD PROVIDED BY CAPATIVEAIRE INSTALLED BY CONTRACTOR.
AutoCAD SHX Text
15
AutoCAD SHX Text
SCALE : N.T.S.
AutoCAD SHX Text
17
AutoCAD SHX Text
SCALE : N.T.S.
AutoCAD SHX Text
18
AutoCAD SHX Text
SCALE : N.T.S.
AutoCAD SHX Text
19
AutoCAD SHX Text
SCALE : N.T.S.
AutoCAD SHX Text
20
AutoCAD SHX Text
SCALE : N.T.S.
AutoCAD SHX Text
21
AutoCAD SHX Text
SCALE : N.T.S.
AutoCAD SHX Text
24
AutoCAD SHX Text
SCALE : N.T.S.
AutoCAD SHX Text
GREASE
AutoCAD SHX Text
INTERCEPTOR
AutoCAD SHX Text
3"
AutoCAD SHX Text
RIGHT SIDE VIEW
AutoCAD SHX Text
* 8" MIN. TO MAX POSSIBLE.
AutoCAD SHX Text
NOTE: PIPING ARRANGEMENT TO BE AS
AutoCAD SHX Text
SHOWN IN MAIN PLUMBING FLOOR PLAN.
AutoCAD SHX Text
REFER TO MECHANICAL DRAWING AND SPECIFICATION.
AutoCAD SHX Text
3 COMPARTMENT SINK
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
C.O.
AutoCAD SHX Text
3"
AutoCAD SHX Text
2"
AutoCAD SHX Text
1-1/2"
AutoCAD SHX Text
PLAN
AutoCAD SHX Text
GREASE INTERCEPTOR TO
AutoCAD SHX Text
BE INSTALLED IN FLOOR
AutoCAD SHX Text
WHERE APPLICABLE.
AutoCAD SHX Text
MECHANICAL DETAIL-2
AutoCAD SHX Text
M8.2
AutoCAD SHX Text
PH.: (905) 946 4260 FAX: (905) 946 0901
AutoCAD SHX Text
MARKHAM ONTARIO L3R 1A3
AutoCAD SHX Text
UNIT 229
AutoCAD SHX Text
7181 WOODBINE AVE
AutoCAD SHX Text
%%UTHOMAS A. FEKETE LIMITED

REFRIGERATION ROOM (002)SEQUENCE OF OPERATION

REFRIGERANT ROOM AIR CIRCULATION DETAIL

DUPLEX SUBMERSIBLE PUMPS AND PIT DETAIL

Exhaust Air

From Space

EF Low Speed Command From Thermostat

BO

EF Low Speed Run Status

BI

EF High Speed Command From Control Panel In Refrigerant Room

BO

EF High Speed Run Status

BI

NC

Outdoor Air

Motorized Damper

NC

Outdoor Air

Motorized Damper

Ventilation Supply Air

Emergency Supply Air

Backdraft

Damper

T

Ammonia

monitor

panel by

others

Leaking Alarm

Ammonia Leaking Alarm

BO

Thermostat AO

Motorized Damper MD-3

AO

Motorized Damper MD-1,2

AO

MCP

FROM MCP PANEL FOR THE COMPRESSOR INTERLOCK BI

Vestibule

switch

FROM VESTIBULE SWITCH

BO

Double

Door

Switch

FROM DOUBLE DOOR SWITCH

BO

DATE INITIALREVISIONSNo.

DESIGN

DATE:

DRAWNCHECKED

DRAWING NUMBER

SIGNED

SCALE: CONTRACT No.

2019-11-01 ISSUED FOR 60% CONSTRUCTION DOCUMENTS1

WS2492514132

CITY ASSET No. 297

DUFFERIN GROVE PARK NORTH-WEST CORNER

AND CLUBHOUSE IMPROVEMENTS

DR

AW

IN

G P

RIN

T D

AT

E: 7/10/2020 5:04:48 P

M

FIL

EN

AM

E: \\T

AF

_S

ER

VE

R\taf_m

ain

\P

ro

jects\C

urren

t P

ro

jects\18173 D

UF

FE

RIN

G

RO

VE

P

AR

K IM

PR

OV

EM

EN

TS

\300 D

esig

n\301 M

E D

wg

s\18173 M

EC

H\18173

m m

etric.d

wg

YA YA BZ

JOB NUMBER: 18173

2020-01-17 ISSUED FOR 90% COORDINATION2

2020-02-14 PROGRESS SET3

2020-03-06 ISSUED FOR PERMIT4

2020-03-06

2020-03-24 ISSUED FOR CD'S5

2020-06-12

2020-06-12 ISSUED FOR TENDER6

AutoCAD SHX Text
EMERGENCY: 1. WHEN THE SIGNAL FOR AMMONIA LEAKING IS SENT TO WHEN THE SIGNAL FOR AMMONIA LEAKING IS SENT TO THE FAN CONTROLLER, MOTORIZED DAMPER (MD-1,2&3) WILL BE FULLY OPENED. THE FAN WILL RUN AT FULL CAPACITY, EXHAUSTING AIR AT 2300 CFM. COOLING SEASONS: 1. WHEN TEMPERATURE READ FROM THE THERMOSTAT WHEN TEMPERATURE READ FROM THE THERMOSTAT REACHES 75°F, THE MOTORIZED DAMPER (MD-1) WILL BEOPENED. EXHAUST FAN -3 IS TURNED ON AND EXHAUST AT 500 CFM. 2. WHEN DOUBLE DOOR SWITCH OR VESTIBULE SWITCH IS WHEN DOUBLE DOOR SWITCH OR VESTIBULE SWITCH IS SWITCHED ON , THE FAN WILL RUN FULL SPEED AND MOTORIZED DAMPERS ARE ALL OPEN. 3. WHEN DOUBLE DOOR SWITCH OR VESTIBULE SWITCH IS WHEN DOUBLE DOOR SWITCH OR VESTIBULE SWITCH IS SWITCHED TO OFF, THE FAN WILL RUN AS PER NORMAL CONTROL SEQUENCE (1 SITUATION OF COOLING/HEATING SEASONS). HEATING SEASONS: 1. UNIT HEATER (UH-2) IS TIED INTO THE THERMOSTAT. UNIT HEATER (UH-2) IS TIED INTO THE THERMOSTAT. WHEN THERMOSTAT READING IS BELOW 72°F. HEATERWILL BE TURNED ON. WHEN ROOM TEMPERATURE REACHES 75°F, UH-2 IS TURNED OFF.2. SAME AS COOLING SEASON 2 AND 3 SWITCH CONTROLS.SAME AS COOLING SEASON 2 AND 3 SWITCH CONTROLS.
AutoCAD SHX Text
16
AutoCAD SHX Text
SCALE : N.T.S.
AutoCAD SHX Text
MD-3
AutoCAD SHX Text
MD-1
AutoCAD SHX Text
NOTE: 1. SUPPLY AND INSTALL 2 48"X48" REFRIGERATION ROOM FRESH AIR INTAKE LOUVERS SUPPLY AND INSTALL 2 48"X48" REFRIGERATION ROOM FRESH AIR INTAKE LOUVERS 2. ONE LOUVER IS CONTROLLED BY A SINGLE MOTORIZED DAMPER. THE OTHER LOUVER IS ONE LOUVER IS CONTROLLED BY A SINGLE MOTORIZED DAMPER. THE OTHER LOUVER IS CONTROLLED BY 2 MOTORIZED DAMPERS. 3. DURING NORMAL OPERATION, ONE OF THE DOUBLE DAMPERS OPEN. DURING NORMAL OPERATION, ONE OF THE DOUBLE DAMPERS OPEN. 4. DURING EMERGENCY WHEN THERE IS AN AMMONIA LEAK, ALL 3 MOTORIZED DAMPER DURING EMERGENCY WHEN THERE IS AN AMMONIA LEAK, ALL 3 MOTORIZED DAMPER SHALL OPEN.
AutoCAD SHX Text
MD-2
AutoCAD SHX Text
NO PIPE / CONDUIT / WIRING IS PERMITTED TO PENETRATE COVERPLATE
AutoCAD SHX Text
2
AutoCAD SHX Text
2.
AutoCAD SHX Text
%%UNOTES:
AutoCAD SHX Text
1.
AutoCAD SHX Text
150 (6")
AutoCAD SHX Text
MIN.
AutoCAD SHX Text
600 (24")
AutoCAD SHX Text
MIN.
AutoCAD SHX Text
150 (6")
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
150 (6")
AutoCAD SHX Text
150 (6")
AutoCAD SHX Text
150 (6")
AutoCAD SHX Text
1
AutoCAD SHX Text
CONDUIT
AutoCAD SHX Text
SEAL GAPS BETWEEN WIRE & CONDUIT WITH NON- SHRINK CAULKING
AutoCAD SHX Text
NON-FERROUS METAL CHAIN
AutoCAD SHX Text
CONCRETE SUMP PIT
AutoCAD SHX Text
BOTH PUMP 'OFF'
AutoCAD SHX Text
ONE PUMP 'ON'
AutoCAD SHX Text
BOTH PUMPS 'ON'
AutoCAD SHX Text
ALARM ON
AutoCAD SHX Text
GALVANIZED BRACKET
AutoCAD SHX Text
VAPOR TIGHT CORD TYPICAL
AutoCAD SHX Text
NEW REMOVABLE GASKETTED AIR TIGHT GALVANIZED STEEL HEAVY DUTY COVER PLATE WITH NON-SKID SURFACE. BOLT COVER PLATE TO FRAME
AutoCAD SHX Text
HIGH WATER ALARM
AutoCAD SHX Text
WIRING IN CONDUIT
AutoCAD SHX Text
CONTROL PANEL
AutoCAD SHX Text
FINISHED FLOOR
AutoCAD SHX Text
32mm STEEL STOP WELDED TO FRAME ALL AROUND
AutoCAD SHX Text
WELDED
AutoCAD SHX Text
HEX HEAD BRASS BOLTS WITH BRASS WASHERS
AutoCAD SHX Text
STEEL COVER PLATE AS PER MANUFACTURERS RECOMMENDATIONS
AutoCAD SHX Text
TUBULAR NEOPRENE GASKET
AutoCAD SHX Text
32mm (1 1/4") STEEL STOP WELDED TO FRAME ALL AROUND
AutoCAD SHX Text
3x25x150 (1/8"x1"x6") STEEL ANGULAR STRAP. TWO PER SIDE
AutoCAD SHX Text
75x75x9 (3"x3"x3/8") ANGLE FRAME
AutoCAD SHX Text
CHECK VALVE
AutoCAD SHX Text
GATE VALVE
AutoCAD SHX Text
PUMPED SANITARY DRAIN PIPE
AutoCAD SHX Text
CLEAN OUT
AutoCAD SHX Text
CROSS OVER PIPING TO BE OFFSET SO THAT PROPER CLEARANCE FOR PUMP REMOVAL IS AVAILABLE OR FLANGED CONNECTION SHALL BE PROVIDED.
AutoCAD SHX Text
75 (3") VENT . TIE INTO THE VENT IN THE SHAFT
AutoCAD SHX Text
CAREFULLY CO-ORDINATE INSTALLATION OF STEEL FRAME, PIPING WITH OTHER DIVISION. IF EXISTING, MAKE SURE THEY ARE IN WORKING CONDITION
AutoCAD SHX Text
23
AutoCAD SHX Text
SCALE : N.T.S.
AutoCAD SHX Text
INLET FROM SNOW MELTING PIT, C/W BACK WATER VALVE
AutoCAD SHX Text
19 GUIDED BAR
AutoCAD SHX Text
MECHANICAL DETAIL-3
AutoCAD SHX Text
M8.3
AutoCAD SHX Text
PH.: (905) 946 4260 FAX: (905) 946 0901
AutoCAD SHX Text
MARKHAM ONTARIO L3R 1A3
AutoCAD SHX Text
UNIT 229
AutoCAD SHX Text
7181 WOODBINE AVE
AutoCAD SHX Text
%%UTHOMAS A. FEKETE LIMITED

1500500

FLOW RATE (cfm)1000

0.000

0.50

PRE

SSU

RE D

ROP

(in. H

20)

PRESSURE DROP VS. FLOW RATE

FRA

CTIO

NA

L E

FFIC

IEN

CY (%

)

00.1

20

40

1.0

PARTICLE DIAMETER (um)10.0

EFFICIENCY VS. PARTICLE DIAMETER

60

80

100

1.00

1.50

2.00

2.50

3.00

3.50

CUSTOMER APPROVAL TO MANUFACTURE: