DPP 106 MW with 7x18V46 HFO - Used Diesel and gas ... · Installed power ... DPP 106 MW with...

7
1. Radiator 2. Power House 3. Switchyard 4. Fuel Oil Storage 5. Fuel Oil Unloading 6. Fuel oil Unloading & Storage 7. Fuel Treatment House 8. Service tank farm area 9. Water Reservoir DPP 106 MW with 7x18V46 HFO 9. Water Reservoir 10. Fire Pump House 11. Sludge tanks 12. Water Treatment Plant 13. Chimney 14. Black start engine 15. Weigh bridge 16. Sludge Treatment unit 17. Station transformer 18. Scrap yard 19. Pre heating area 20. Effluent Treatment Plant 21. Vapor Absorption Machine

Transcript of DPP 106 MW with 7x18V46 HFO - Used Diesel and gas ... · Installed power ... DPP 106 MW with...

Page 1: DPP 106 MW with 7x18V46 HFO - Used Diesel and gas ... · Installed power ... DPP 106 MW with 7x18V46 HFO Plant Main Data. DPP 106 MW with 7x18V46 HFO Techncial High Lights Generators

1. Radiator2. Power House3. Switchyard4. Fuel Oil Storage5. Fuel Oil Unloading6. Fuel oil Unloading & Storage7. Fuel Treatment House8. Service tank farm area9. Water Reservoir10. Fire Pump House11. Sludge tanks12. Water Treatment Plant13. Chimney14. Black start engine15. Weigh bridge16. Sludge Treatment unit17. Station transformer18. Scrap yard19. Pre heating area20. Effluent Treatment Plant21. Vapor Absorption Machine

DPP 106 MW with 7x18V46 HFO

1. Radiator2. Power House3. Switchyard4. Fuel Oil Storage5. Fuel Oil Unloading6. Fuel oil Unloading & Storage7. Fuel Treatment House8. Service tank farm area9. Water Reservoir10. Fire Pump House11. Sludge tanks12. Water Treatment Plant13. Chimney14. Black start engine15. Weigh bridge16. Sludge Treatment unit17. Station transformer18. Scrap yard19. Pre heating area20. Effluent Treatment Plant21. Vapor Absorption Machine

Page 2: DPP 106 MW with 7x18V46 HFO - Used Diesel and gas ... · Installed power ... DPP 106 MW with 7x18V46 HFO Plant Main Data. DPP 106 MW with 7x18V46 HFO Techncial High Lights Generators

DPP 106 MW with 7x18V46 HFOAreal views

Page 3: DPP 106 MW with 7x18V46 HFO - Used Diesel and gas ... · Installed power ... DPP 106 MW with 7x18V46 HFO Plant Main Data. DPP 106 MW with 7x18V46 HFO Techncial High Lights Generators

Installed power (Site) 106 MW at 110 kV / 50 Hz Engine Type Wartsila 18V46 HFO Number of generators 7 identical units Alternators ABB AMG 1600, 11 kV, 50Hz Commissioning time Mid 2001 Operating hours 50700 to 69000 hours / unit Maintenance made 3 units for 60 000 major,others strictly accordance withManufacturer’s requirements Fuel consumption 8290 - 8330 kJ/kWh gross(43.4 to 43.2 % efficiency) Fuel used LSHS/LSFO 380 cSt, 2 % S Lube Oil used Mobilgard M50 Power Evacuation 4 x 110kV feeders

DPP 106 MW with 7x18V46 HFOPlant Main Data

Installed power (Site) 106 MW at 110 kV / 50 Hz Engine Type Wartsila 18V46 HFO Number of generators 7 identical units Alternators ABB AMG 1600, 11 kV, 50Hz Commissioning time Mid 2001 Operating hours 50700 to 69000 hours / unit Maintenance made 3 units for 60 000 major,others strictly accordance withManufacturer’s requirements Fuel consumption 8290 - 8330 kJ/kWh gross(43.4 to 43.2 % efficiency) Fuel used LSHS/LSFO 380 cSt, 2 % S Lube Oil used Mobilgard M50 Power Evacuation 4 x 110kV feeders

Page 4: DPP 106 MW with 7x18V46 HFO - Used Diesel and gas ... · Installed power ... DPP 106 MW with 7x18V46 HFO Plant Main Data. DPP 106 MW with 7x18V46 HFO Techncial High Lights Generators

DPP 106 MW with 7x18V46 HFOTechncial High Lights

Generators are best heavy fuel oil unitsin the market type Wartsilä 18V46 with500 rpm running speed Very well maintained equipment withhigh efficiency and proven availability State of the art continuous emissionmonitoring system for oxygen, sulfurdioxide, nitrous oxides and carbonmonoxide. WOIS and WISE monitoring system forplant operation and data acquisition isfully functional. Proven technology PLC system, ModiconQuantum series,Software-ConceptVersion: 2.2.

Generators are best heavy fuel oil unitsin the market type Wartsilä 18V46 with500 rpm running speed Very well maintained equipment withhigh efficiency and proven availability State of the art continuous emissionmonitoring system for oxygen, sulfurdioxide, nitrous oxides and carbonmonoxide. WOIS and WISE monitoring system forplant operation and data acquisition isfully functional. Proven technology PLC system, ModiconQuantum series,Software-ConceptVersion: 2.2.

Page 5: DPP 106 MW with 7x18V46 HFO - Used Diesel and gas ... · Installed power ... DPP 106 MW with 7x18V46 HFO Plant Main Data. DPP 106 MW with 7x18V46 HFO Techncial High Lights Generators

0102030405060708090

100

%

Availability % PLF %

Availability % 97.3 97 96.9 93.2 97.1 97.8 94.7 92.1 94.7 94.5 84.1 92.1 97.5 94.3 94.5PLF % 64.4 67.4 50.3 37.8 36.4 40.9 56.3 72.6 51.6 39.1 31.1 39.5 38.2 27 46.6

2001-02

2002-03

2003-04

2004-05

2005-06

2006-07

2007-08

2008-09

2009-10

2010-11

2011-12

2012-13

2013-14

2014-15 Avg

DPP 106 MW with 7x18V46 HFOPast Performance

0102030405060708090

100

%

Availability % PLF %

Availability % 97.3 97 96.9 93.2 97.1 97.8 94.7 92.1 94.7 94.5 84.1 92.1 97.5 94.3 94.5PLF % 64.4 67.4 50.3 37.8 36.4 40.9 56.3 72.6 51.6 39.1 31.1 39.5 38.2 27 46.6

2001-02

2002-03

2003-04

2004-05

2005-06

2006-07

2007-08

2008-09

2009-10

2010-11

2011-12

2012-13

2013-14

2014-15 Avg

Note: 1) Year 2001-02 data are from 22nd Sept. ‘01 to 31st March ’022) Year 2011-12 availability is less due to major overhauls

Page 6: DPP 106 MW with 7x18V46 HFO - Used Diesel and gas ... · Installed power ... DPP 106 MW with 7x18V46 HFO Plant Main Data. DPP 106 MW with 7x18V46 HFO Techncial High Lights Generators

Scheduled EnginesServ. No Hours # 1 # 2 # 3 # 4 # 5 # 6 # 71 12000 x x x x x x x2 24000 x x x x x x x3 36000 x x x x x x x4 48000 x x x x x x5 60000 x x x Current engine hours 69028 54297 52418 64052 70939 55712 50718

DPP 106 MW with 7x18V46 HFOMaintenance & operating hours

Scheduled EnginesServ. No Hours # 1 # 2 # 3 # 4 # 5 # 6 # 71 12000 x x x x x x x2 24000 x x x x x x x3 36000 x x x x x x x4 48000 x x x x x x5 60000 x x x Current engine hours 69028 54297 52418 64052 70939 55712 50718

Page 7: DPP 106 MW with 7x18V46 HFO - Used Diesel and gas ... · Installed power ... DPP 106 MW with 7x18V46 HFO Plant Main Data. DPP 106 MW with 7x18V46 HFO Techncial High Lights Generators

DPP 106 MW with 7x18V46 HFOPicture Gallery

MV SwitchesMV Switches Switchyard panels Fire pumps

DG Hall backside Sludge treatment Fuel unloding pumps