DIVATOP 60 New Wall Hung Gas Fired Boiler. Divatop 60: Main Features Leader in wall hung boilers...

14
DIVATOP 60 DIVATOP 60 New Wall Hung Gas Fired Boiler

Transcript of DIVATOP 60 New Wall Hung Gas Fired Boiler. Divatop 60: Main Features Leader in wall hung boilers...

DIVATOP 60DIVATOP 60New Wall Hung Gas Fired Boiler

Divatop 60: Main FeaturesLeader in wall hung boilersLeader in wall hung boilers

FerroliFerroli, in line with its position as a comfort multinational, one of the major players at a world level, permanently carries out research and trials on new products, so as to respond to the continuously evolving expectations of the users and the market.

The DIVATOP 60 project was devoted to satisfy the needs of users who require large amounts of immediately available domestic hot water. Thanks to the generous 60 litre AISI 316 STAINLESS STEEL storage tank, lined with special insulating material, this boiler can satisfy simultaneous demand for hot water from multiple points of delivery. The outputs of the various models, 24 and 32 kW respectively, guarantee the extremely fast refill of the water in the storage tank, with maximum comfort for the user.The DIVATOP 60 supplies domestic hot water with the highest efficiency in its category. It is in fact certified by 3 STARS according to the European directive EN 13203.

The DIVATOP 60 boilers can connected to a modulating remote control via opentherm. Romeo serie is made by four models, with daily or weekly comfort planning; for both of them it’s possible to choose wired or wireless connection.With Romeo is possible to adjust the CH and DHW temperature, to watch the temperature inside and outside the house, get report of faults and reset the boiler, to plan the daily or weekly comfort and to turn on and off the boiler by mobile phone (using an optional dialer)

Romeo: The remote timer controlRomeo: The remote timer control

Divatop 60: Main Divatop 60: Main FeaturesFeatures

The DIVATOP 60 electronic controller offers the antifreeze function on the central heating circuit. If heating circuit’s water temperature falls below +6°C, the burner will ignite again until the temperature reaches +15°C. In this period, the central heating pump is kept on. This protection device remains active only if the boiler is plugged and supplied with gas.

Antifreeze DeviceAntifreeze Device

Divatop 60: Main Divatop 60: Main FeaturesFeaturesOperation with Temperature CompensationOperation with Temperature Compensation

The “Outside probe” kit can be installed to operate the boiler with temperature compensation.This means that without using the buttons on the system’s temperature controller, the boiler automatically adapts to the variations in the outside temperature. As a result this brings energy savings while still granting maximum comfort to the user.

Anti-legionella functionAnti-legionella functionLegionella is a typical form of water contamination caused by bacteria that are particularly dangerous to the health. These bacteria can be destroyed by heating the water to temperatures above 60°C. This is why the DIVATOP 60, at least once a week, heats the water in the storage tank to 65°C, autonomously from the tank’s temperature setpoint.

ModelModel C 24C 24 C 32C 32 F 24F 24 F 32F 32

Energy certification (92/42 EEC) 2 2 3 3

Heat Input max kW 25,8 33,1 25,8 33,3

Heat Input min kW 11,5 14,5 8,3 10,7

Useful max Heat Output in heating kW 23,3 30 24 31

Useful min Heat Output in heating kW 9,7 12,7 7,2 9,2

Useful Thermal Efficiency (80°-60°C)

% 90,5 % 90,5 % 93 % 93 %

NOx emission class 3 3 3 3

Max Working Pressure in Heating Bar 3 3 3 3

DHW circuit operating pressure min-max

Bar 0,25-9 0,25-9 0,25-9 0,25-9

Central heating expansion vessel capacity

Lt 8 10 8 10

Dhw expansion vessel capacity Lt 2 2 2 2

Domestic hot water tank capacity Lt 60 60 60 60

Hot water flow rate Dt 30°C l/min 180 200 180 210

Hot water flow rate Dt 30°C l/h 740 910 750 950

Power consumption W 85 85 125 140

Empty weight Kg 54 56 60 62

Divatop 60: Technical Divatop 60: Technical DataData

Divatop 60: Divatop 60: DimensionsDimensionsWidth

Heig

ht

Depth

Divatop 60: Bottom Divatop 60: Bottom viewview

1: CH Flow ¾’’; 2: CH Return ¾’’; 3: Gas inlet ½; 4: DHW Inlet ½; 5: DHW outlet ½’’1: CH Flow ¾’’; 2: CH Return ¾’’; 3: Gas inlet ½; 4: DHW Inlet ½; 5: DHW outlet ½’’

C modelC model

F modelF model

Divatop 60: Divatop 60: ComponentsComponents

Modulating high pressure fanModulating high pressure fan

Copper heat exchangerCopper heat exchangerwith high efficiencywith high efficiency

BurnerBurner

New Digital displayNew Digital display

Domestic hot water tankDomestic hot water tank

All models are fitted All models are fitted with two pumps: one with two pumps: one for the central for the central heating function, and heating function, and a separate pump for a separate pump for domestic hot water domestic hot water production.production.

TWO EXPANSION TWO EXPANSION VESSELSVESSELSThe boilers are fitted The boilers are fitted with two expansion with two expansion vessels.vessels.In the central heating In the central heating circuit, 8 litres in the 24 circuit, 8 litres in the 24 kW model and 10 litres kW model and 10 litres in the 32 kW model. In in the 32 kW model. In the domestic hot water the domestic hot water circuit, 2 litres. circuit, 2 litres.

Divatop 60: Heat Divatop 60: Heat ExchangerExchanger

COPPER HEAT EXCHANGER “MONOTHERMIC”

FERROLI DESIGN AND PATENT

HEAT EXCHANGER STORAGE TANK

Hight Efficiency of Exchanging

Mod. 32 kWT 30 °C 210 L/10 min.T 30 °C 950 L/hMod. 24 kWT 30 °C 200 L/10 min.T 30 °C 910 L/h

MagnesiumAnode

Reci

rcula

tion

DHW inlet

DHW outlet

STORAGE TANK 60 LITRES INOX AISI 316 BIGGER COIL COMPLETE THERMAL INSULATION

COLD WATER INLET

SANITARY EXPANSIONVESSEL 2 LITRES

DHW OUTLET PIPE

INSPECTION PLATE

MAGNESIUMANODE

Divatop 60: Domestic Hot Water Storage Divatop 60: Domestic Hot Water Storage TankTank

Divatop 60: Digital Divatop 60: Digital DisplayDisplay

Keys for DHW Temperature setting

Wide back-litLcd display

Keys for CH Temperature setting

Summer / winter swich:Summer only CHWinter: CH + DHW

Eco-comfort switcheson or off heating of DHW tank

On-off

Mode temperature compensationCurve setting

Reset key

Divatop 60: General Divatop 60: General ViewView 5 Sealed Chamber

7 Gas Inlet8 Dhw delivery9 Dhw inlet10 System delivery11 System return14 Safety valve16 Fan19 Combustion chamber22 Burner27 Copper exchanger28 Fume manifold29 Fume outlet collar32 Heating circulating pump40 Dhw expansion vassel43 Air pressure switch44 Gas valve56 CH expansion valve81 Ignition electrode90 Fume measurement point91 Air measurement point187 Flue diaphragm221 By pass243 Sensor246 Pressure transducer

Divatop 60: Hydraulic Divatop 60: Hydraulic CircuitCircuit

5 Sealed chamber7 Gas inlet8 Dhw outlet9 Dhw inlet10 System delivery11 System return14 Safety valve16 Fan20 Burner assembly27 Heat exchanger29 Fume outlet collar32 Heating circulating pump43 Air pressure switch44 Gas valve56 Expansion tank81 Ignition electrode187 Fume diaphragm221 By pass243 Sensor246 Water pressure transducer278 Double sensor (safety + heating)

Half a century as a specialist in HVAC