Determination of First Clock in & Last Clock

49
Generated by Jive on 2014-08-12+02:00 1 Determination of First Clock In & Last Clock Out in Positive Time Evaluation Client Situation  Our client requirement was to implement SAP HR Positive Time Management solution to record and evaluate the actual times of their blue collar workers. The client was installing time recording terminals which were not SAP CC1 certified. Only Clock In (Time Event Type P10) and Clock Out (Time Event Type P20) were required to be recorded.  The factory/plant had four production shops. Each production shop had two time recording terminals mounted on the wall - one for clock in and another for clock out. These time recording terminals didn't have any unique way to specify whether a time punched at time recording terminal is "clock in" or "clock out". Hence, there was a board mounted with the sign "Clock In" above "Clock In Time Recording Terminal" and with the sign "Clock Out" above "Clock Out Time Recording Terminal". Some employees had access to all production shops and some had access to few of them only. An employee could work in multiple production shops in the same shift. Each time an employee entered into a production shop, it was expected that he clocked in at the "Clock In Time Recording Terminal" while entering into the production shop and clocked out at the "Clock Out Time Recording Terminal" while leaving the production shop.  There were no turnstiles at the entrance of production shops and hence, there was a high chance that employees may forget to clock in or clock out while entering or leaving the production shops. Hence, we could have scenarios where an employee has a clock in data once and clock out data multiple times for the same shift.  For evaluation purposes, client wanted us to consider the first clock in and the last clock out since it was difficult to enforce employees to clock in while entering and clock out while leaving the production shop in absence of a turnstile. If the first clock in was missing, then it should be reported as a missing clock in. Also, if the last clock out was missing, then it should be reported as a missing clock out. The time recording system would send a .txt file with all the time events (P10 & P20) data recorded for a shift for all employees in that shift in a predefined format to SAP R/3. These time events would be uploaded in IT2011 (Table TEVEN). Hence, if the time events were recorded as shown in the table below, the first clock in will be blank and the last clock out will be 18:00:00.  Date P10 P20 03-Jan-2012 - 14:00:00 03-Jan-2012 14:15:00 18:00:00  

Transcript of Determination of First Clock in & Last Clock

Page 1: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 1/49

Generated by Jive on 2014-08-12+02:00

1

Determination of First Clock In & Last ClockOut in Positive Time Evaluation

Client Situation 

Our client requirement was to implement SAP HR Positive Time Management solution to record and evaluate

the actual times of their blue collar workers. The client was installing time recording terminals which were not

SAP CC1 certified. Only Clock In (Time Event Type P10) and Clock Out (Time Event Type P20) were required

to be recorded.

 

The factory/plant had four production shops. Each production shop had two time recording terminals mounted

on the wall - one for clock in and another for clock out. These time recording terminals didn't have any unique

way to specify whether a time punched at time recording terminal is "clock in" or "clock out". Hence, there

was a board mounted with the sign "Clock In" above "Clock In Time Recording Terminal" and with the sign

"Clock Out" above "Clock Out Time Recording Terminal". Some employees had access to all production shops

and some had access to few of them only. An employee could work in multiple production shops in the same

shift. Each time an employee entered into a production shop, it was expected that he clocked in at the "Clock

In Time Recording Terminal" while entering into the production shop and clocked out at the "Clock Out Time

Recording Terminal" while leaving the production shop.

 

There were no turnstiles at the entrance of production shops and hence, there was a high chance that

employees may forget to clock in or clock out while entering or leaving the production shops. Hence, we could

have scenarios where an employee has a clock in data once and clock out data multiple times for the same

shift.

 

For evaluation purposes, client wanted us to consider the first clock in and the last clock out since it was

difficult to enforce employees to clock in while entering and clock out while leaving the production shop in

absence of a turnstile. If the first clock in was missing, then it should be reported as a missing clock in. Also, if

the last clock out was missing, then it should be reported as a missing clock out.

The time recording system would send a .txt file with all the time events (P10 & P20) data recorded for a shift

for all employees in that shift in a predefined format to SAP R/3. These time events would be uploaded in

IT2011 (Table TEVEN).

Hence, if the time events were recorded as shown in the table below, the first clock in will be blank and the last

clock out will be 18:00:00.

 

Date P10 P20

03-Jan-2012 - 14:00:00

03-Jan-2012 14:15:00 18:00:00

 

Page 2: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 2/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

2

There was no requirement to record break times and employees could clock in/clock out multiples times for the

same shift. The break time would be considered from the daily work schedule.

 

Failed Solution Approach 

For quite some time, this requirement was giving me sleepless nights. There were various approaches which I

was trying out but none of them gave the desired results.

One such approach tried by me was to use operation VARST to read the first time pair (VARSTFIRST) and

then use operation HRS=PBEG to capture the no. of hours and enter it into a time type.

Then use operation VARST to read the last time pair (VARSTLAST) and use operation HRS=PEND to capture

the no. of hours and enter it into another time type.

Using the time types, I would modify the start time and end time using operation FILLP for the first time pair

and ignore the remaining time pairs.

On the face of it, this solution looked good. However, it had inherent shortcomings.

Please refer the below screenshot for time events in IT2011 to understand the shortcomings. The employee

recorded a clock in at 08:00:00 and then clock outs at 10:30:00, 14:00:00 and 18:00:00 on 03-Jan-12.

 

When the time evaluation is run, the time pairs formed get sorted as shown in the screenshot below:

 

Page 3: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 3/49

Page 4: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 4/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

4

earliest or latest recorded times from the time events that have actually got recorded at the time

recording terminals.• Out of the recorded clock ins, find the earliest recorded clock in and latest recorded clock in.

• Find all the recorded clock outs for the shift from the time pairs formed in Table TIP from functionP2011.

• Out of this recorded clock outs, find the earliest recorded clock out and latest recorded clock out.

• Then compare the earliest recorded clock in with earliest recorded clock out. If the earliestrecorded clock in is less than the earliest recorded clock out, then the earliest recorded clock in is the

first clock in of the shift and should be called P10. If the earliest recorded clock in is greater than theearliest recorded clock out, then there is a missing clock in. Hence, the first clock in of the shift should

be blank.• Then compare the latest recorded clock out with the latest recorded clock in. If the latest

recorded clock out is greater than the latest recorded clock in, then the latest recorded clock out isthe last clock out of the shift and should be called P20. If the latest recorded clock out is less than thelatest recorded clock in, then there is a missing clock out. Hence, the last clock out of the shift should

be blank.

Let us now test this logic to the time events in our failed solution approach. Below table shows the time pairs

formed in Table TIP from function P2011.

 

Earliest Recorded Clock In = 08.0000

Latest Recorded Clock In = 08.0000

Earliest Recorded Clock Out = 10.5000

Latest Recorded Clock Out = 18.0000

We see that the “earliest recorded clock in” (08.0000) is less than the “earliest recorded clock

out” (10.5000) and hence, the “earliest recorded clock in” is the first clock in of the shift. This is

correct. The “latest recorded clock out” (18.0000) is greater than the “latest recorded clock in” (08.0000)

and hence, the “latest recorded clock out” is the last clock out of the shift. This is correct too.

Hence, the above solution logic proved correct and I built custom PCRs and time types to fulfill the requirement

based on this logic.

 

Solution Design

 

Page 5: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 5/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

5

There are two key tables which we would need to maintain to build this solution.

• TPT_PAIRSTAT2 - Pair Formation: Status Table• V_T705B - PDC Processing Statuses

 

Table TPT_PAIRSTAT2 determines how time pairs are formed in Table TIP.

Below is a partial screenshot of the Pair Formation Status Table.

 

From State: At any time, an employee has a state. This is the state in which the employee is in before the timeevent happens.

Time Event Type: The field shows the time event recorded when the employee is in a given state.

It will change the state of the employee from “From state” to “To State”.

Unique Time Event Type: Time Event Type P01 can be used to record both clock in/clock out. If 

the “From state” of employee is absent before clock in and the “Time Event Type” is P01, then it

means that the employee has clocked in. In such a case, the value of “Unique time event type”

will be P10. This interpretation is defined in this field. Where no unique interpretation is required,

the value of time event type is same as unique time event type. As shown in the screenshot

above, the value of both time event type and unique time event type are P10 for “From state” –Absent before Clock In because no unique interpretation is needed.

To State: This is the state at which employee reaches from “From State” once the time event type

is recorded.

Continue: This field is used for interim postings. Let us say that there is an interim posting

between clock out and clock in and we would like to have two complete pairs – one from clock out

to interim posting and another from interim posting to clock in. The first two events form the first

Page 6: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 6/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

6

time pair and the third event ends the new time pair taking the end event of previous time pair

as the start event of the new time pair.

Closed: Time pairs are formed by a starting time event and an ending time event. However,

if a time event is missing, then the pair won’t get formed or if there are multiple time events,

incorrect time pairs may be formed. To avoid any errors, this check box should be checked for

scenarios where the time event type is the ending time event and there is a missing starting time

event type. This implies that the time event should create a new closed time pair only with “To”

time and the “From” time will be blank. An example of this scenario is where clock in is missing

and clock out is recorded.

Close: This field is meant to close an open time pair if it exists. If the employee is at work and a

time event is recorded and this field is checked, then the pair should be closed. Fields Close and

Closed are mutually exclusive. Both of them can’t be maintained at the same time for the same

states and time event type.

New: This field means that a new time pair should be started.

Customer Adjustment: This field is used to specify PDC Processing Status and its reaction maintained in

Table V_T705B.

Error: If the pair formation is not error free, it gives an error message in time evaluation run corresponding to

the error message number maintained here.

Pair Formation Status: This field gives the status of the time pair formed – whether it is error free

or not or clock in is missing or clock out is missing etc.

Let us now understand the PDC Processing Statuses Table V_T705B.

 This table specifies the actions to be taken in situations where time pairs can’t be formed

because the time events data don’t make sense.

 

Page 7: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 7/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

7

PSGrp: This is Grouping of Personnel Subareas for Time Recording for which the same time types, time

transfer specifications, access control groups, and message types are defined.

PDC Processing Status: This field displays the PDC Processing Status which defines the behavior to be

taken into account during time pair formation.

Processing Status Text: This field displays the description of the PDC Processing Status.Start Date: This field displays the start date from which the PDC Processing Status is valid.

End Date: This field displays the end date till which the PDC Processing Status is valid.

Reaction: The return code in field reaction will specify the reactions to be taken for PDC Processing Status.

Let us now study the values relevant for our scenarios from Pair Formation Status Table and the relevant

values (C02 & C11) from PDC Processing Statuses Table.

 TPT_PAIRSTAT2 Screenshot A – This shows the values in the table relevant for our scenarios.

 

V_T705B Screenshot B – The highlighted rows in the table show the values relevant for our

scenarios.

 

Page 8: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 8/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

8

 

Let us refer to the 2nd and 6th rows in Table TPT_PAIRSTAT2 Screenshot A. In both cases, employee

was not at work and there was a clock out recorded. The system has to create a time pair with

the clock out time event because the field “Closed” is checked. The “Customer adjustment” field

has PDC Processing Status as C02 and the error message 21 (Clock in Missing) will get generated.

 The reaction field in Table V_T705B Screenshot B for PDC Processing Status C02 should be left

blank to allow open time pair creation with only clock out time in Table TIP from function P2011.

 The time pair will have “From” field blank and “To” field with clock out time.

 The other possible reaction value for PDC Processing Status C02 is 1. If 1 is maintained, then it

doesn’t allow even creation of open time pair with just clock out data.

Below are the examples of system behavior with reaction as blank and as 1 for PDC Processing Status C02.

PDC Processing Status Scenario 1: Reaction indicator is blank for PDC Processing Status C02.

V_T705B

 

IT2011

 

Page 9: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 9/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

9

 

P2011 – Open Pair Type gets created with clock out data and clock in is missing.

 

 Time Evaluation Result – The time evaluation fails with error that clock in is missing.

 

Page 10: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 10/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

10

PDC Processing Status Scenario 2: Reaction indicator is 1 for PDC Processing Status C02.

V_T705B

 

IT2011

 

Page 11: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 11/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

11

 

 Time Evaluation Result – The time evaluation fails at PCR TD20 which points out that time pair is

not error free and has clock in missing. It doesn’t allow the system to reach function P2011 which

creates open time pair with clock out time. Hence, this option is ruled out.

 

Page 12: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 12/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

12

Let us refer to the 3rd

 row in Table TPT_PAIRSTAT2 Screenshot A. The employee was at work and a

clock in was recorded. The field “Close” is checked and hence, it will close the open pair. Also, the

field “New” is checked and hence, it will start the creation of a new time pair. The PDC Processing

Status in field “Customer Adjustment” is C11. The reaction indicator for PDC Processing Status

C11 is 1. If the reaction is 1, the system will end ongoing time pair with the current clock in time

and also start a new time pair with the same clock in time. If the reaction for PDC Processing

Status is blank, the system will give an error that clock in is missing.

PDC Processing Status Scenario 3: Reaction indicator is 1 for PDC Processing Status C11.

V_T705B

 

IT2011 – Employee is at work (Clock In 08:00:00) and clocks in again (14:00:00). It means that

there is a missing clock out between two clock ins.

 

Page 13: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 13/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

13

 

P2011 – There wasn’t any clock out at 14.0000. However, the system closes the existing open

pair with the clock in time and starts a new time pair with the same clock in time. This is due to

PDC Processing Status C11 and its return code as 1.

 

 Time Evaluation Result – The time evaluation run is successful.

 

Page 14: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 14/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

14

 

PDC Processing Status Scenario 4: Reaction indicator is blank for PDC Processing Status C11.

V_T705B

 

Page 15: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 15/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

15

IT2011 – Employee is at work (Clock In 08:00:00) and clocks in again (14:00:00). It means that

there is a missing clock out between two clock ins.

 

 Time Evaluation Result – The time evaluation fails at PCR TD20 and generates error during pair

formation. It doesn’t allow system to reach function P2011 for processing. Hence, this option is

ruled out. 

Page 16: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 16/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

16

 

After maintaining Pair Formation Status Table - TPT_PAIRSTAT2 and PDC Processing Statuses Table -

V_T705B, the next step is to create time types. Below are the daily time types which are needed.

• Earliest Recorded Clock In – ZVB1• Latest Recorded Clock In – ZVB2• Earliest Recorded Clock Out – ZVB3• Latest Recorded Clock Out – ZVB4• First Clock In – ZVB5• Last Clock Out – ZVB6

 

Go to TCode SM30 > Table V_T555A.

ZVB1 – Earliest Recorded Clock In

 

Page 17: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 17/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

17

 

ZVB2 – Latest Recorded Clock In

 

Page 18: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 18/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

18

 ZVB3 – Earliest Recorded Clock Out

 

Page 19: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 19/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

19

 

ZVB4 – Latest Recorded Clock Out

 

Page 20: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 20/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

20

 

ZVB5 – First Clock In

 

Page 21: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 21/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

21

 

ZVB6 – Last Clock Out

 

Page 22: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 22/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

22

 

After creating the six daily time types, I created five PCRs as mentioned below:

• ZVB4 - Find Earliest Recorded Clock In and Latest Recorded Clock In• ZVB5 - Find Earliest Recorded Clock Out and Latest Recorded Clock Out• ZVB6 - Determine First Clock In

• ZVB7 - Determine Last Clock Out• ZVB9 - Form Time Pair in TIP using First Clock In & Last Clock Out

 

Let us now go inside each PCR to understand its functionality.

 

PCR ZVB4 – The objective of PCR ZVB4 is to find the “earliest recorded clock in” and “latest

recorded clock in” in a shift and feed the values in daily time types ZVB1 (earliest recorded clock

in) and ZVB2 (latest recorded clock in).

Page 23: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 23/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

23

If no clock in has been recorded, then the daily time types ZVB1 and ZVB2 won’t get generated.

If only one clock in has been recorded, then both ZVB1 and ZVB2 will have the same value.

Below is a screenshot of PCR ZVB4.

 

Let us see how time pairs in TIP table get processed through PCR ZVB4.

•  The PCR checks if start time exists in time pair or not using OUTTPEXBTM. If start time

doesn’t exist (N), the time pair is moved to output table using COLOP *. If all time pairs

of the shift don’t have start time, then time types ZVB1 and ZVB2 aren’t created. Hence,

the values of ZVB1 and ZVB2 are 0.

 

• If the start time exists (Y) in time pair, the value of time type ZVB1 (Earliest Recorded Clock In) isread using HRS=DZVB1. If it is the first time pair with start time and getting processed in the rule, thevalue of ZVB1 will be 0. If it is not the first time pair with start time, then there will be some value in

time type ZVB1.

 

Page 24: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 24/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

24

• After reading the value of time type ZVB1, it is compared with 0 using HRS?0. If the value of

ZVB1 is not greater than 0, it is processed under * and the start time of the time pair is read usingHRS=PBEG. The start time is added to time types ZVB1 (earliest recorded clock in) and ZVB2 (latest

recorded clock in) and the time pair is moved to output table using COLOP *.

 

• Let us assume that the first time pair with start time had start time as 10:00:00. Hence,the value of ZVB1 and ZVB2 will be 10.0000. Now let us assume that the next time pair

with start time has start time as 08:00:00. This time pair will get processed through

 Y (OUTTPEXBTM). The value of time type ZVB1 is read using HRS=DZVB1 (ZVB1 =

10.0000). This value is compared with 0 using HRS?0 and since the value of ZVB1

(10.0000) is greater than 0, the time pair gets processed under >. Then the start time of 

the time pair is read using HRS=PBEG (HRS = 08.0000) and it is compared with “earliest

recorded clock in” time type ZVB1 (10.0000) using HRS?DZVB1. Since the value of 

HRS=PBEB (08.0000) is not greater than ZVB1 (10.0000), the start time of this time pair

is the new “earliest recorded clock in” for this shift and gets processed under *. Hence,

the start time (08.0000) of the current time pair is fed into daily time type ZVB1 after

removing its old value 10.0000 using ADDDBZVB1Z and the time pair is moved to output

table using COLOP *.

 

• Currently, the value of ZVB1 and ZVB2 are 08.0000 and 10.0000 respectively. Let us

assume now that the next time pair with start time has start time as 15:00:00. This time

pair will get processed through Y (OUTTPEXBTM). The value of time type ZVB1 is read

using HRS=DZVB1 (ZVB1 = 08.0000). This value is compared with 0 using HRS?0 and

since the value of ZVB1 (08.0000) is greater than 0, the time pair gets processed under

>. Then the start time of the time pair is read using HRS=PBEG (HRS = 15.0000) and

it is compared with “earliest recorded clock in” time type ZVB1 (08.0000) using HRS?

DZVB1. Since the value of HRS=PBEG (15.0000) is greater than “earliest recorded clock

in” time type ZVB1 (08.0000), the time pair gets processed under >. Then the value

of HRS=PBEG (15.0000) is compared with “latest recorded clock in” time type ZVB2(10.0000). Since the value of HRS=PBEB (15.0000) is greater than ZVB2 (10.0000), the

start time of this time pair is the new “latest recorded clock in” for this shift and it gets

processed under >. Hence, the start time (15.0000) of the current time pair is fed into

daily time type ZVB2 after removing its old value 10.0000 using ADDDBZVB2Z and the

time pair is moved to output table using COLOP *.

 

• Currently, the value of ZVB1 and ZVB2 are 08.0000 and 15.0000 respectively. Let us

assume now that the next time pair with start time has start time as 13:00:00. This time

pair will get processed through Y (OUTTPEXBTM). The value of time type ZVB1 is read

using HRS=DZVB1 (ZVB1 = 08.0000). This value is compared with 0 using HRS?0 and

since the value of ZVB1 (08.0000) is greater than 0, the time pair gets processed under>. Then the start time of the time pair is read using HRS=PBEG (HRS = 13.0000) and

it is compared with “earliest recorded clock in” time type ZVB1 (08.0000) using HRS?

DZVB1. Since the value of HRS=PBEG (13.0000) is greater than “earliest recorded clock

in” time type ZVB1 (08.0000), the time pair gets processed under >. Then the value

of HRS=PBEG (13.0000) is compared with “latest recorded clock in” time type ZVB2

(15.0000). Since the value of HRS=PBEB (13.0000) is not greater than ZVB2 (15.0000),

the start time of this time pair is not the new “latest recorded clock in” for this shift and

Page 25: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 25/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

25

it gets processed under *. Hence, this time pair is moved into output table using COLOP

*.

 

• Finally, the value of “earliest recorded clock in” time type ZVB1 and “latest recorded

clock in” time type ZVB2 are 08.0000 and 15.0000 respectively.

 

PCR ZVB5 – The objective of PCR ZVB5 is to find the “earliest recorded clock out” and “latest

recorded clock out” in a shift and feed the values into daily time types ZVB3 (earliest recorded

clock out) and ZVB4 (latest recorded clock out).

If no clock out has been recorded, then the daily time types ZVB3 and ZVB4 won’t get generated.

If only one clock out has been recorded, then both ZVB3 and ZVB4 will have the same value.

Below is a screenshot of PCR ZVB5. 

Let us see how time pairs in TIP table get processed through PCR ZVB5.

Page 26: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 26/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

26

•  The PCR checks if end time exists in time pair or not using OUTTPEXETM. If end time

doesn’t exist (N), the time pair is moved to output table using COLOP *. If all time pairs of 

the shift don’t have end time, then time types ZVB3 and ZVB4 aren’t created. Hence, the

values of ZVB3 and ZVB4 are 0.

 

• If the end time exists (Y) in time pair, the value of time type ZVB3 (Earliest Recorded Clock Out) isread using HRS=DZVB3. If it is the first time pair with end time and getting processed in the rule, the

value of ZVB3 will be 0. If it is not the first time pair with end time, then there will be some value intime type ZVB3.

 

• After reading the value of time type ZVB3, it is compared with 0 using HRS?0. If the value of ZVB3 is

not greater than 0, then the time pair gets processed under * and the end time of the time pair is readusing HRS=PEND. The end time is added to time types ZVB3 (earliest recorded clock out) and ZVB4

(latest recorded clock out) and the time pair is moved to output table using COLOP *.

 

• Let us assume that the first time pair with end time had end time as 12:00:00. Hence,

the value of ZVB3 and ZVB4 will be 12.0000. Now let us assume that the next time

pair with end time has end time as 10:00:00. This time pair will get processed through

 Y (OUTTPEXETM). The value of time type ZVB3 is read using HRS=DZVB3 (ZVB3 =

12.0000). This value is compared with 0 using HRS?0 and since the value of ZVB3

(12.0000) is greater than 0, the time pair gets processed under >. Then the end time of 

the time pair is read using HRS=PEND (HRS = 10.0000) and it is compared with “earliest

recorded clock out” time type ZVB3 (12.0000) using HRS?DZVB3. Since the value of 

HRS=PEND (10.0000) is not greater than ZVB3 (12.0000), the end time of this time

pair is the new “earliest recorded clock out” for this shift and it gets processed under *.

Hence, the end time (10.0000) of the current time pair is fed into daily time type ZVB3

after removing its old value 12.0000 using ADDDBZVB3Z and the time pair is moved to

output table using COLOP *.

 

• Currently, the value of ZVB3 and ZVB4 are 10.0000 and 12.0000 respectively. Let us

assume now that the next time pair with end time has end time as 18:00:00. This time

pair will get processed through Y (OUTTPEXETM). The value of time type ZVB3 is read

using HRS=DZVB3 (ZVB3 = 10.0000). This value is compared with 0 using HRS?0 and

since the value of ZVB3 (10.0000) is greater than 0, the time pair gets processed under

>. Then the end time of the time pair is read using HRS=PEND (HRS = 18.0000) and it

is compared with “earliest recorded clock out” time type ZVB3 (10.0000) using HRS?

DZVB3. Since the value of HRS=PEND (18.0000) is greater than “earliest recorded clock

out” time type ZVB3 (10.0000), the time pair gets processed under >. Then the value

of HRS=PEND (18.0000) is compared with “latest recorded clock out” time type ZVB4

(12.0000). Since the value of HRS=PEND (18.0000) is greater than ZVB4 (12.0000), the

end time of this time pair is the new “latest recorded clock out” for this shift and the time

pair is processed under *. Hence, the end time (18.0000) of the current time pair is fed

into daily time type ZVB4 after removing its old value 12.0000 using ADDDBZVB4Z and

the time pair is moved to output table using COLOP *.

 

Page 27: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 27/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

27

• Currently, the value of ZVB3 and ZVB4 are 10.0000 and 18.0000 respectively. Let us

assume now that the next time pair with end time has end time as 16:00:00. This time

pair will get processed through Y (OUTTPEXETM). The value of time type ZVB3 is read

using HRS=DZVB3 (ZVB1 = 10.0000). This value is compared with 0 using HRS?0 and

since the value of ZVB3 (10.0000) is greater than 0, the time pair gets processed under

>. Then the start time of the time pair is read using HRS=PEND (HRS = 16.0000) and

it is compared with “earliest recorded clock out” time type ZVB3 (10.0000) using HRS?DZVB3. Since the value of HRS=PEND (16.0000) is greater than “earliest recorded clock

out” time type ZVB3 (10.0000), the time pair gets processed under >. Then the value

of HRS=PEND (16.0000) is compared with “latest recorded clock out” time type ZVB4

(18.0000). Since the value of HRS=PEND (16.0000) is less than ZVB4 (18.0000), the

end time of this time pair is not the new “latest recorded clock out” for this shift and the

time pair gets processed under <. Hence, this time pair is moved into output table using

COLOP *.

 

• Finally, the value of “earliest recorded clock out” time type ZVB3 and “latest recorded

clock out” time type ZVB4 are 10.0000 and 18.0000 respectively.

 

PCR ZVB6 – The objective of PCR ZVB6 is to find the “first clock in” by comparing “earliest clock

in” time type ZVB1 with “earliest clock out” time type ZVB3. If the value of ZVB1 is less than

ZVB3, then ZVB1 is the “first clock in” and its value should be fed in time type ZVB5 – First Clock

In.

If the value of ZVB1 is more than ZVB3, then there is a “missing clock in”. The “missing clock in”

is the “first clock in” and hence, the value of ZVB5 will be 0.0000.

If ZVB1 was not created due to “missing clock in”, then the value of ZVB5 will be 0.0000 implying

that there is a “missing clock in”.

 

Below is a screenshot of PCR ZVB6.

 

Page 28: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 28/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

28

 

• Scenario 1: “Earliest Recorded Clock In” Time Type ZVB1 not created and “Earliest

Recorded Clock Out” Time Type ZVB3 has value 10.0000 - The PCR ZVB6 reads the

value of “earliest recorded clock in” time type ZVB1 (blank) using HRS=DZVB1 and then

subtracts the value of “earliest recorded clock out” time type ZVB3 (10.0000) using HRS-DZVB3. The result is compared with 0 using HRS?0 and since this is not greater than 0, it

gets processed under *. The value of “earliest recorded clock in” time type ZVB1 is read

using HRS=DZVB1 and is fed into “first clock in” time type ZVB5 using ADDDBZVB5Z.

 The value of ZVB5 is 0.0000 implying that the “first clock in” is missing.

 

• Scenario 2: “Earliest Recorded Clock In” Time Type ZVB1 has value 08.0000 and “Earliest

Recorded Clock Out” Time Type ZVB3 has value 10.0000 - The PCR ZVB6 reads the value

of “earliest recorded clock in” time type ZVB1 (08.0000) using HRS=DZVB1 and then

subtracts the value of “earliest recorded clock out” time type ZVB3 (10.0000) using HRS-

DZVB3. The result is compared with 0 using HRS?0 and since this is not greater than

0, it gets processed under *. The value of “earliest recorded clock in” time type ZVB1(08.0000) is read using HRS=DZVB1 and is fed into “first clock in” time type ZVB5 using

ADDDBZVB5Z. Hence, the value of ZVB5 is 08.0000.

 

• Scenario 3: “Earliest Recorded Clock In” Time Type ZVB1 has value 12.0000 and “Earliest

Recorded Clock Out” Time Type ZVB3 has value 10.0000 - The PCR ZVB6 reads the value

of “earliest recorded clock in” time type ZVB1 (12.0000) using HRS=DZVB1 and then

Page 29: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 29/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

29

subtracts the value of “earliest recorded clock out” time type ZVB3 (10.0000) using HRS-

DZVB3. The result is compared with 0 using HRS?0 and since this is greater than 0, it

gets processed under >. The result is compared with “earliest recorded clock in” time

type ZVB1 (12.0000) using operation HRS?DZVB1 and since the result is less than the

value of ZVB1, it gets processed under <. Using HRS=0.00, the value is set to 0 and then

fed into “first clock in” time type ZVB5 using ADDDBZVB5Z. Hence, the value of ZVB5 is

0.0000 implying that the “first clock in” is missing.

 

• Scenario 4: “Earliest Recorded Clock In” Time Type ZVB1 has value 08.0000 and “Earliest

Recorded Clock Out” Time Type ZVB3 has value 0.0000 - The PCR ZVB6 reads the value

of “earliest recorded clock in” time type ZVB1 (08.0000) using HRS=DZVB1 and then

subtracts the value of “earliest recorded clock out” time type ZVB3 (0.0000) using HRS-

DZVB3. The result is compared with 0 using HRS?0 and since this is greater than 0, it

gets processed under >. The result is compared with “earliest recorded clock in” time

type ZVB1 (08.0000) using operation HRS?DZVB1 and since the result is equal to the

value of ZVB1, it gets processed under =. The value of “earliest recorded clock in” time

type ZVB1 (08.0000) is read using HRS=DZVB1 and then fed into “first clock in” timetype ZVB5 using ADDDBZVB5Z. Hence, the value of ZVB5 is 08.0000.

 

PCR ZVB7 – The objective of PCR ZVB7 is to find the “last clock out” by comparing “latest clock

out” time type ZVB4 with “latest clock in” time type ZVB2. If the value of ZVB4 is greater than

ZVB2, then ZVB4 is the “last clock out” and its value should be fed in time type ZVB6 – Last Clock

Out.

If the value of ZVB4 is less than ZVB2, then there is a “missing clock out”. The “missing clock

out” is the “last clock out” and hence, the value of ZVB6 will be 0.0000.

If ZVB4 was not created due to “missing clock out”, then the value of ZVB6 will be 0.0000

implying that there is a “missing clock out”.

Below is a screenshot of PCR ZVB7.

 

Page 30: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 30/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

30

 

• Scenario 1: “Latest Recorded Clock Out” Time Type ZVB4 not created and “Latest

Recorded Clock In” Time Type ZVB2 has value 12.0000 - The PCR ZVB7 reads the value of 

“latest recorded clock out” time type ZVB4 (blank) using HRS=DZVB4 and then subtracts

the value of “latest recorded clock in” time type ZVB2 (12.0000) using HRS-DZVB2.

 The result is compared with 0 using HRS?0 and since this is not greater than 0, it gets

processed under *. Using HRS=0.00, the value is set to 0 and then fed into “last clock

out” time type ZVB6 using ADDDBZVB6Z. Hence, the value of ZVB6 is 0.0000 implying

that the “last clock out” is missing.

 

• Scenario 2: “Latest Recorded Clock Out” Time Type ZVB4 has value 18.0000 and “Latest

Recorded Clock In” Time Type ZVB2 has value 12.0000 - The PCR ZVB7 reads the value

of “latest recorded clock out” time type ZVB4 (18.0000) using HRS=DZVB4 and then

subtracts the value of “latest recorded clock in” time type ZVB2 (12.0000) using HRS-

DZVB2. The result is compared with 0 using HRS?0 and since this is greater than 0,

it gets processed under >. The value of “latest recorded clock out” time type ZVB4

(18.0000) is read using HRS=DZVB4 and then fed into “last clock out” time type ZVB6

using ADDDBZVB6Z. Hence, the value of ZVB6 is 18.0000.

 • Scenario 3: “Latest Recorded Clock Out” Time Type ZVB4 has value 14.0000 and “Latest

Recorded Clock In” Time Type ZVB2 has value 16.0000 - The PCR ZVB7 reads the value

of “latest recorded clock out” time type ZVB4 (14.0000) using HRS=DZVB4 and then

subtracts the value of “latest recorded clock in” time type ZVB2 (16.0000) using HRS-

DZVB2. The result is compared with 0 using HRS?0 and since this is not greater than

0, it gets processed under *. Using HRS=0.00, the value is set to 0 and then fed into

“last clock out” time type ZVB6 using ADDDBZVB6Z. Hence, the value of ZVB6 is 0.0000

implying that the “last clock out” is missing.

Page 31: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 31/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

31

 

• Scenario 4: “Latest Recorded Clock Out” Time Type ZVB4 has value 18.0000 and “Latest

Recorded Clock In” Time Type ZVB2 not created - The PCR ZVB7 reads the value of 

“latest recorded clock out” time type ZVB4 (18.0000) using HRS=DZVB4 and then

subtracts the value of “latest recorded clock in” time type ZVB2 (0.0000) using HRS-

DZVB2. The result is compared with 0 using HRS?0 and since this is greater than 0,it gets processed under >. The value of “latest recorded clock out” time type ZVB4

(18.0000) is read using HRS=DZVB4 and then fed into “last clock out” time type ZVB6

using ADDDBZVB6Z. Hence, the value of ZVB6 is 18.0000.

 

By now, we have identified the “first clock in” and “last clock out” of a shift. We also have the

solution logic in place to identify if the “first clock in” or “last clock out” of any shift is missing or

not.

 

PCR ZVB9 - The next step is to create a time pair using the “first clock in” and “last clock out”

that we have determined and process only this time pair for further evaluation. Any other time

pair if present gets eliminated from further processing.

Below is the screenshot of PCR ZVB9.

 

Page 32: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 32/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

32

 

 The PCR ZVB9 uses VARSTFIRST to read the first time pair. If it is the first time pair, it gets

processed under Y. Any other time pair gets stopped at N and doesn’t move to output table. In

this way, we are ensuring that only one time pair will move to output table for further processing.

 The first time pair will be modified with the “first clock in” and “last clock out” data and will be

moved to output for further processing.Below are the four possible scenarios that may happen.

 

Scenario 1: Both “First Clock In” (ZVB5) and “Last Clock Out” (ZVB6) have value as 0.0000 – The

first time pair moves for processing under Y. The value of “first clock in” time type ZVB5 (0.0000)

is read using HRS=DZVB5 and then compared with 0 using HRS?0. Since the result is not greater

than 0, the processing happens under *. Below things happen for the first time pair:

Page 33: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 33/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

33

• The start time of the time pair is deleted using FILLPB-

• The start of record type (P10) is deleted using FILLPF• The no. of hours is reduced to 0.0000 using FILLPN

 

 Then the value of the “last clock out” time type ZVB6 (0.0000) is read using HRS=DZVB6 and

then compared with 0 using HRS?0. Since the result is not greater than 0, the processing

happens under *. Below things happen for the first time pair:

 

• The end time of the time pair is deleted using FILLPE-

• The end of record type (P20) is deleted using FILLPG• The status of the time pair is changed to 1 using FILLP11 implying that both start and end times are

missing from the time pair

• The time pair is moved to output table for further processing using COLOP *.• Hence, the time pair has both “From” time and “To” time as blank.

 

Scenario 2: “First Clock In” (ZVB5) and “Last Clock Out” (ZVB6) have value as 0.0000 and 18.0000

respectively – The first time pair moves for processing under Y. The value of “first clock in” time

type ZVB5 (0.0000) is read using HRS=DZVB5 and then compared with 0 using HRS?0. Since the

result is not greater than 0, the processing happens under *. Below things happen for the first

time pair:

• The start time of the time pair is deleted using FILLPB-• The start of record type (P10) is deleted using FILLPF• The no. of hours is reduced to 0.0000 using FILLPN

 

 Then the value of the “last clock out” time type ZVB6 (18.0000) is read using HRS=DZVB6 and

then compared with 0 using HRS?0. Since the result is greater than 0, the processing happens

under >. Below things happen for the first time pair:

•  The end time of the time pair is filled with value of “last clock out” time type ZVB6

(18.0000) using FILLPE.• The end of record type (P20) is added to time pair using FILLPG

• The status of the time pair is changed to 2 using FILLP12 implying that clock in time is missing fromtime pair.

• The time pair is moved to output table for further processing using COLOP *.• Hence, the time pair has “From” time and “To” time as blank and 18.0000 respectively.

 

Scenario 3: “First Clock In” (ZVB5) and “Last Clock Out” (ZVB6) have value as 08.0000 and 0.0000

respectively – The first time pair moves for processing under Y. The value of “first clock in” time

type ZVB5 (08.0000) is read using HRS=DZVB5 and then compared with 0 using HRS?0. Since

the result is greater than 0, the processing happens under >. Below things happen for the first

time pair:

Page 34: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 34/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

34

 

•  The start time of the time pair is set from “first clock in” time type ZVB5 using FILLPB.• The start of record type (P10) is set for time pair using FILLPFP10.

 

 Then the value of the “last clock out” time type ZVB6 (0.0000) is read using HRS=DZVB6 and

then compared with 0 using HRS?0. Since the result is not greater than 0, the processing happens

under *. Below things happen for the first time pair:

 

• The end time of the time pair is deleted using FILLPE-• The end of record type (P20) is deleted using FILLPG

• The no. of hours is reduced to 0.0000 using FILLPN• The status of the time pair is changed to 3 using FILLP13 implying that clock out time is missing from

time pair.

• The time pair is moved to output table for further processing using COLOP *.• Hence, the time pair has “From” time and “To” time as 08.0000 and blank respectively.

 

Scenario 4: “First Clock In” (ZVB5) and “Last Clock Out” (ZVB6) have value as 08.0000 and

18.0000 – The first time pair moves for processing under Y. The value of “first clock in” time type

ZVB5 (08.0000) is read using HRS=DZVB5 and then compared with 0 using HRS?0. Since the

result is greater than 0, the processing happens under >. Below things happen for the first time

pair:

 

•  The start time of the time pair is set from “first clock in” time type ZVB5 using FILLPB.• The start of record type (P10) is set for time pair using FILLPFP10.

 

 Then the value of the “last clock out” time type ZVB6 (18.0000) is read using HRS=DZVB6 and

then compared with 0 using HRS?0. Since the result is greater than 0, the processing happens

under >. Below things happen for the first time pair:

 

•  The end time of the time pair is set from “last clock out” time type ZVB6 (18.0000) using

FILLPE.• The end of record type (P20) is set for time pair using FILLPGP20.• The status of the time pair is changed to 0 using FILLP10 implying that the pair is error free with both

start time and end time.• The time pair is moved to output table for further processing using COLOP *.

• Hence, the time pair has “From” time and “To” time as 08.0000 and 18.0000respectively.

 

The next step is to include these PCRs ZVB4, ZVB5, ZVB6, ZVB7 and ZVB9 in positive time management

schema.

Page 35: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 35/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

35

A custom schema ZTCN is created by copying from standard time schema TM00 – Time

Evaluation with Personnel Time Events.

Below is a screenshot of the custom time schema ZTCN.

 

The PCRs ZVB4, ZVB5, ZVB6, ZVB7 and ZVB9 are included in time schema ZTCN as per the sequence

shown in the above screenshot.

PCRs ZVB4, ZVB5 and ZVB9 are being processed by function PTIP because TIP table is being processed in

these PCRs. Par 2 is GEN because it is called for all time types.

PCRs ZVB6 and ZVB7 are being processed by function ACTIO because TIP table is not being processed in

these PCRs.

I have included function PRINT after PCRs ZVB4 and ZVB5 to print table TES to display the value of time

types ZVB1, ZVB2, ZVB3 and ZVB4 which get generated in these PCRs.

Page 36: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 36/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

36

In the same way, I have included function PRINT after PCRs ZVB6 and ZVB7 to print table TES to display the

value of time types ZVB5 and ZVB6 which get generated in these PCRs.

I tested around 22 different scenarios for this solution and all the scenarios passed with the desired result.

 

Please refer the below screenshots for the results.

 

Page 37: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 37/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

37

 

I will now pick up some scenarios from the 22 scenarios that I tested and show how the time events got

processed in system.

 Testing Scenario 1:

IT2011

 

P2011

 

Page 38: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 38/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

38

 

Table TES

 

Final Pair Formed

 

Page 39: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 39/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

39

 

 Time Evaluation Result – It fails since last clock out is missing.

 

Page 40: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 40/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

40

 

Testing Scenario 2:

IT2011

 

Page 41: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 41/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

41

 

P2011

 

Page 42: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 42/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

42

 

Table TES

 

Final Pair Formed

 

 Time Evaluation Result – It fails since first clock in is missing.

 

Page 43: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 43/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

43

 

Testing Scenario 3:

IT2011

 

Page 44: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 44/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

44

 

P2011

 

Page 45: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 45/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

45

 

Table TES

 

Final Pair Formation

 

 Time Evaluation Result – It fails since last clock out is missing

 

Page 46: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 46/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

46

 

Testing Scenario 4:

IT2011

 

Page 47: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 47/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

47

P2011

 

Table TES

 

Page 48: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 48/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation

Generated by Jive on 2014-08-12+02:00

48

 

Final Pair Formation

 

 Time Evaluation Result – It is successful.

 

Here I come to the end of this knowledge artifact. Thank you for your patience for going through this document.

I hope this knowledge artifact has been beneficial for you.

 

Warm regards,

Vivek Barnwal,

[email protected]

**************************************************************************************************

You can also refer to other knowledge artifacts created by me at the below link:

One Stop Shop of my Knowledge Artifacts in SAP HCM

Page 49: Determination of First Clock in & Last Clock

8/12/2019 Determination of First Clock in & Last Clock

http://slidepdf.com/reader/full/determination-of-first-clock-in-last-clock 49/49

Determination of First Clock In & Last Clock Out in Positive Time Evaluation