Design calculation report - Pipe rack - and foundation

download Design calculation report - Pipe rack - and foundation

of 128

Transcript of Design calculation report - Pipe rack - and foundation

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    1/128

     

       D   E   S   C   R   I   P   T   I   O   N

       R   E   V

       N   O .

       J   O   /   E   W   O

       D   A   T   E

       O   P   R   N   S

       E   N   G   G

       P   M   T

       C   E   R   T

    DATE:

    DATE:

    DATE:

    DATE:

    DATE:

       D   A   T   E  :

       B   Y  :

       C   O   N   T   R   O   L   N

       U   M   B   E   R

    PROJECT

    ENGINEER

    CONSTRUCTION

    AGENCY

    DISCIPLINE

    ENGINEER

     

       V   E   R   I   F   I   C   A   T   I   O   N

      E  D  S

      D

        R   E   V   I   S   I   O   N

       C   E   R   T   I   F   I   C   A   T   E

       T   H   I   S   I   N   D   I   C   A   T   E   S   T   H   A   T   R   E   V .

       N   O .__________

       O   F   T   H   I   S   D   R   A   W   I   N   G   I   S   C   O   V   E   R   E   D ,

       F   O   R   A   L   L

       A   P   P   R   O   V   A   L   /   C   E   R   T   I   F   I   C   A   T   I   O   N   R   E   Q   U   I   R   E   M   E   N   T   S ,

       B   Y   D   R   A   W   I   N   G   C   O   M   P   L   E   T   I   O   N   C   E   R   T   I   F   I   C   A   T   E

       (   D   C   C   )   N   O ._____________________

    OPERATIONS

    CERTIFIED

     

       R   E   V   I   S   I   O   N

       C   E   R   T   I   F   I   C   A   T   I   O   N

     

    1Of

    1

    DOCV73 Q

    JO / EWO: 

    0F21-00052-0001

       2   1  -   0   0   0   5   2  -   0   0   0   1  -   0   0   1

       0   F   1

     

    09/09/13

    S.A SAKKAK

    09/09/13

    09/09/13

    M. GHANIM

    M. GHANIM

    04/03/13

       S   A   S  

       M   A   G 

       A   A   M 

       R   E  -   I   S   S   U   E   D

       F   O   R

       C   O   N   S   T   R   U   C   T   I   O   N

     

    A. MACAUMBANG

     

       2   1  -   0   0   0   5   2  -

       0   0   0   1

     

       0   9   /   0   9   /   1   3

     

       0   F   1  

    STRUCTURAL CALCULATIONS

    METERING BUILDING

    PIPELINE BETWEEN SHEDGUM & YANBU

    SHEDGUM EDSD/2616-0399.d

    Saudi Aramco 2616-ENG (03/99)

       B

    SAUDI ARABIA

    REV.NSHT.NO. DRAWING NO. INDEX PLANT NO. DWG.TYPE 

    SAUDI ARABIAN OIL COMPANY

    CAL-STR-001

    Saudi Aramco, Northern Area Projects Dep.

    /NAOO & BGP Project’s Division

    J.O #-21-00052-0001

    Structural CalculationMetering Building

    Sales Gas Delivery System for Saudi ElectricityCo. PP12

    RE-ISSUED FOR CONSTRUCTION

    PREPARED BY: 

    MUSTANG-HDPAl-Khobar, Saudi Arabia

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    2/128

    PROJECT: JOB NO.: BI-21-00052 SHEET NO.:

    LOCATION: DESIGN BY: AAM DATE: 09/09/2013

    CLIENT: CHECKED BY: SAM APPROVED BY: MAG

    1.0 BUILDING GEOMETRY

    INTRODUCTION

    This specification list the design criteria used while performing calculations for design of all structural items related

    to Metering Shelter/Building. Briefly described herein are the structural systems of the building, design

    approach adopted, various codes used, material properties, loads, allowable limits in deflections and stability and the

    soil properties. This criterion complies with all relevant engineering standards, latest editions of engineering and industry

    codes and Saudi Arabian Government codes.

    BUILDING DIMENSIONS:

    The proposed Metering Shelter/Building has following dimensions:

    From Ground Floor to roof:

    Length: 11.5.0m clear between grid line 1 & 1.

    Width: 8.25m clear between grid line A & C

    Height: 4.8m from finish floor line to top of roof slab.

    STRUCTURAL SYSTEMS DESCRIPTION

    The structural system consists of :

    Structure: Reinforced concrete frames

    Walls:

    Roof: reinforced concrete slab.

    Parapet 150mm thick reinforced concrete

    Foundation: Isolated footing

    Floor slab: Concrete slab on grade

    DESIGN APPROACH

    Metering Shelter/Building is modeled and analyzed using STAAD PRO software.The structure will be analyzed and

    designed for conventional static loads such as dead load, live load, wind load & seismic load. Isolated spread footing

    will be designed according to anticipated column load or supprt reactions and allowable soil bearing

    capacity.Other governing codes and standards applicable to the structure are used in preparation of the design.

    APPLICABLE CODES AND STANDARDS

    The following codes and standards are used in the design:

    SEI/ASCE 7 – 02 Minimum design loads for buildings and other structures.

    SAES M-100 Saudi Aramco Building Code

    SALES GAS DELIVERY SYSTEM

    RIYADH

    SAUDI ARAMCO

    250mm thick cmu block walls above ground level

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    3/128

    PROJECT: JOB NO.: BI-21-00052 SHEET NO.:

    LOCATION: DESIGN BY: AAM DATE: 09/09/2013

    CLIENT: CHECKED BY: SAM APPROVED BY: MAG

    SALES GAS DELIVERY SYSTEM

    RIYADH

    SAUDI ARAMCO

    UBC - 1997 Uniform Building code

    ACI-318-2005 American Concrete Institute, Building Requirements for Reinforced Concrete.

    MATERIALS

    Concrete

    f’c = 28 MPa Minimum concrete compressive strength at 28 days for all cast-in-situ reinforced concrete

    structural elements.

    f’c = 28 MPa Minimum concrete compressive strength at 28 days for all cast-in-situ reinforced concrete

    slabs on grade

    f’c = 17 MPa Minimum structural plain or lean concrete compressive strength at 28 days.

    Reinforcing Steel:

     fy = 420 MPa (60 Ksi) Minimum yield strength of all reinforcing steel. Reinforcing bars shall conform to

    SASO-SSA-2, ASTM A615/A615M grade 60.

    Cement:

    Portland cement shall be of type V Cement in all cases, Ready mixed concrete shall have a minimum specified

    compressive strength fc' = 28 Mpa (4000 psi) after 28 days.

    Welded Wire Fabric

    Shall conform to SASO SSA 224/1981(cold drawn) plain fabric wire with minimum yield strength of 240 MPa.

    DESIGN LOAD BASIS

    Dead Loads

    Unit Weights of different building materials

    Reinforced concrete= = 24 kN/m3

    Mortar, cement = 20.4 kN/m3

    Gravel = 16.3 kN/m3

    Soil = 18.0 kN/m3

    2.0 LOAD COMPUTATION & DISTRIBUTION

    2.1 DEAD LOAD:

    2.1.1 Dead Loads on Roof:

    DL of 200mm thick concrete slab = 4.80 KN/M2

    DL of water proofing (2 ply) + 50mm thick rigid insulation = 0.55 KN/M2

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    4/128

    PROJECT: JOB NO.: BI-21-00052 SHEET NO.:

    LOCATION: DESIGN BY: AAM DATE: 09/09/2013

    CLIENT: CHECKED BY: SAM APPROVED BY: MAG

    SALES GAS DELIVERY SYSTEM

    RIYADH

    SAUDI ARAMCO

    DL of 50mm thick gravel finish = 0.82 KN/M2

    DL of 50mm thick structural screed = 1.02 KN/M2

    Collateral Loads (ceiling & lighting) = 0.50 KN/M2

    Additional roof load 0.70 KN/M2

    Total Dead Loads = 8.39 KN/M2

    2.1.2 Parapet Loads:

    DL of 150mm thick reinforced concrete parapet = 3.60 KN/M2

    2.1.3 Wall Loads:

    External Walls:

    DL of 250mm thick cmu wall = 5.75KN/M

    2

    DL of 50mm thick insulation = 0.15 KN/M2

    DL of 12mm plaster one side = 0.25 KN/M2

    Total Dead Load of Built-up Walls  = 6.15 KN/M2

    2.2 LIVE LOAD:

    2.2.1 Live Load on roof  = 1.00 KN/M2

    2.2.2 Live Load on Ground Floor (slab on grade) = 4.80 KN/M2

    2.4 SEISMIC LOAD:

    Seismic Load will be generated by Staad using DEFINE UBC LOAD command with the

    following parameters:

    Ss 0.70: S1 = 0.2: I 1.0: RWX 3.0: RWZ 3.0: SCL 4

    Where:

    I - Importance Factor

    Rx & Rz - Response Modification Coefficient for Intermediate Moment Resisting Frame

    SCL site class

    2.5 WIND LOAD:

    Wind Load Calculated in accordance with ASCE-7-05 based on a maximum wind velocity

    of 145Km/hr.

    qz = 0.613 *Kz *Kzt* Kd*V2* I (Eq-6-15 of ASCE-7-05)

    Where V = 145 km/h = 40.6 m/sec

    Exposure C , Category III G = 0.85

    I = 1.15 kzt = 1.00

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    5/128

    PROJECT: JOB NO.: BI-21-00052 SHEET NO.:

    LOCATION: DESIGN BY: AAM DATE: 09/09/2013

    CLIENT: CHECKED BY: SAM APPROVED BY: MAG

    SALES GAS DELIVERY SYSTEM

    RIYADH

    SAUDI ARAMCO

    kz = 1.00 kd = 1.00

    qz = 1.16 KN/M2

    2.5.1 Wind force

    P = qz(GCpf –GCpi)

    GCpf = External Pressure Coefficient

    = 0.40 Fig-6.10-ASCE-7-05

    GCpi = Internal Pressure Coefficient

    = +0.18 Fig-6.10-ASCE-7-05

    = -0.18 Fig-6.5-ASCE-7-05

    P1 = 0.67 KN/M2

    P2 = 0.26 KN/M2

    3.0 LOAD COMBINATIONS

    Allowable Stress Combinations

    1 DL + LL Where:

    3 0.6DL + WL DL Dead Load

    4  DL + 0.75(LL +WL) LL Live Load

    5 DL +0.75 (LL +E) WL Wind Load

    6 DL + 0.75(LL +0.707WLX+0.707WLZ) , E Earthquake7 0.6DL + 0.7E

    8 DL + 0.75( LL +E/1.4)

    Strength Design Load Combinations.

    1 1.4D

    2 1.2DL + 1.6LL

    5 1.2 DL + 1.6 LL + 0.8 WL

    6 1.2DL + 0.5LL + 1.6WL

    7

    1.2DL +LL + E8 0.9 DL + 1.6 WL

    9 0.9DL + E

    4.0 BEAM DEFLECTION

    L / 240 25.00  mm

    Maximum beam deflection as per staad output beam 114 : 4.58  mm

    Allowable beam defelection as per code : 

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    6/128

    PROJECT: JOB NO.: BI-21-00052 SHEET NO.:

    LOCATION: DESIGN BY: AAM DATE: 09/09/2013

    CLIENT: CHECKED BY: SAM APPROVED BY: MAG

    SALES GAS DELIVERY SYSTEM

    RIYADH

    SAUDI ARAMCO

    5.0 STRUCTURAL DESIGN ANALYSIS

    3.0 COMPUTER INPUT FILE 3.0 COMPUTER INPUT FILE 3.0 COMPUTER INPUT FILE 3.0 COMPUTER INPUT FILE 

    STRUCTURE & LOAD DIAGRAM STRUCTURE & LOAD DIAGRAM STRUCTURE & LOAD DIAGRAM STRUCTURE & LOAD DIAGRAM 

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    7/128

    STRUCTURE 3D RENDERED VIEW

    STRUCTURE 3D VIEW

    Load 6

    X

    Y

    Z

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    8/128

    STRUCTURE W/ NODE NUMBER

    STRUCTURE W/ BEAM NUMBER

    5

    9

    19

    3

    6

    8

    14

    1

    18

    4

    7

    20

    12

    15

    17

    2

    27

    29

    13

    24

    16

    26

    28

    21

    23

    11

    25

    22

    Load 6

    XY

    Z

    325

    6

    8

    2

    36

    27

    10

    5

    7

    13

    23

    1

    26

    16

    9

    4

    18

    12

    24

    2134

    20

    15

    1735

    40

    22

    30

    38

    3332

    14

    28

    31

    1939

    29

    3741

    Load 6

    XY

    Z

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    9/128

    STRUCTURE W/ DIMENSIONS

    STRUCTURE W/ NODE NUMBER @ SUPPORT

    1 m3 m

    4.8 m

    2.75 m

    1 m

    6 m

    6 m

    5.75 m

    4.8 m

    5.75 m

    1 m

    6 m

    1 m

    3 m

    4.8 m

    5.75 m

    4.8 m

    2.75 m

    1 m

    6 m

    6 m2.85 m

    5.75 m

    4.8 m

    2.9 m2.25 m

    1 m

    6 m

    1 m

    2.85 m

    2.25 m2.9 m

    4.8 m

    1 m

    4.8 m

    2.9 m2.25 m

    4.8 m

    2.25 m2.9 m

    Load 6

    XY

    Z

    1

    29

    21

    5

    1412

    24

    3

    Load 1XY

    Z

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    10/128

    SEISMIC LOAD @ X DIRECTION

    SEISMIC LOAD @ Z DIRECTION

    0.135

    0.168

    0.562

    0.128

    0.135

    1.011

    0.175

    0.168

    0.562

    0.087

    0.562

    0.076

    0.854

    0.1280.075

    0.389

    0.075

    0.486 0.162

    0.162

    Load 1X

    Y

    Z

    0.135

    0.168

    0.562

    0.128

    0.135

    1.011

    0.175

    0.168

    0.562

    0.087

    0.562

    0.076

    0.854

    0.128

    0.075

    0.389

    0.075

    0.486

    0.162

    0.162

    Load 2X

    Y

    Z

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    11/128

    DEAD LOAD

    ROOF LIVE LOAD

    -29.520

    -29.520

    -29.520

    -29.520

    -24.121-24.121 (GY)

    -2.160

    -29.520

    -24.121-24.121 (GY)-24.121-24.121 (GY)

    -2.160

    -29.520

    -24.121-24.121 (GY)

    -2.160

    -29.520

    2*-24.1212*-24.121 (GY)2*-24.1212*-24.121 (GY)

    -29.520

    -29.520

    -24.121-24.121 (GY)

    -2.160

    -29.520

    -24.121-24.121 (GY)-24.121-24.121 (GY)

    -2.160

    -23.912 (GY)

    -2.160

    -29.520-29.520

    -24.121-24.121 (GY)-23.912

    -9.439-9.439 (GY)-9.439-9.439 (GY)

    -9.439-9.439 (GY)-2.160

    -9.439-9.439 (GY)-2.160

    -9.439-9.439 (GY)-9.439-9.439 (GY)

    -2.160

    Load 3X

    Y

    Z

    -2.875-2.875 (GY)

    -2.875-2.875 (GY)-2.875-2.875 (GY)

    -2.875-2.875 (GY)

    2*-2.8752*-2.875 (GY)2*-2.8752*-2.875 (GY)

    -2.875-2.875 (GY)

    -2.875-2.875 (GY)-2.875-2.875 (GY)

    -2.850 (GY)-2.875-2.875 (GY)-2.850

    -1.125-1.125 (GY)-1.125-1.125 (GY)

    -1.125-1.125 (GY)

    -1.125-1.125 (GY)-1.125-1.125 (GY)

    -1.125-1.125 (GY)

    Load 4X

    Y

    Z

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    12/128

    WIND LOAD @ X DIRECTIONS

    WIND LOAD @ -X DIRECTIONS

    16.955

    11.834

    23.313

    6.358

    16.271

    4.438

    Load 5X

    Y

    Z

    4.264

    5.230

    4.264

    5.230

    Load 6X

    Y

    Z

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    13/128

    WIND LOAD @ -Z DIRECTIONS

    WIND LOAD @ Z DIRECTIONS

    12.363

    8.124

    11.341

    28.258

    22.681

    16.249

    11.341

    Load 7X

    Y

    Z

    3.109

    2.043

    5.013

    5.046

    2.026

    7.497

    2.061

    2.484

    2.061

    2.528

    2.528

    Load 8X

    Y

    Z

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    14/128

    PROJECT: JOB NO.: BI-21-00052 SHEET NO.:

    LOCATION: DESIGN BY: AAM DATE: 09/09/2013

    CLIENT: CHECKED BY: SAM APPROVED BY: MAG

    SALES GAS DELIVERY SYSTEM

    RIYADH

    SAUDI ARAMCO

    3.0A COMPUTER INPUT FILE 3.0A COMPUTER INPUT FILE 3.0A COMPUTER INPUT FILE 3.0A COMPUTER INPUT FILE 

    DESIGN OF METERING SHELTER DESIGN OF METERING SHELTER DESIGN OF METERING SHELTER DESIGN OF METERING SHELTER 

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    15/128

    ProV8i\STAAD\Plugins\METERING BUILDING-1642K.std 09/09/13 07:39:41

    D SPACET JOB INFORMATIONNEER DATE 30-Mar-13JOB INFORMATIONT WIDTH 79METER KNT COORDINATES0 0; 2 0 5.8 0; 3 5.75 0 0; 4 5.75 5.8 0; 5 11.5 0 0; 6 11.5 5.8 0;1 0; 8 5.75 1 0; 9 11.5 1 0; 11 0 5.8 6; 12 5.75 0 6; 13 5.75 5.8 6;1.5 0 6; 15 11.5 5.8 6; 16 0 1 6; 17 5.75 1 6; 18 11.5 1 6; 19 8.5 1 0;.5 1 6; 21 0 0 8.25; 22 0 5.8 8.25; 23 0 1 8.25; 24 2.9 0 8.25;.9 5.8 8.25; 26 2.9 1 8.25; 27 2.9 1 6; 28 2.9 5.8 6; 29 0 0 6;ER INCIDENCES7; 2 3 8; 3 5 9; 4 7 2; 5 8 4; 6 9 6; 7 7 8; 8 8 19; 9 2 4; 10 4 6;

    2 17; 13 14 18; 14 16 11; 15 17 13; 16 18 15; 17 16 27; 18 17 20; 19 11 28;3 15; 21 7 16; 22 2 11; 23 6 15; 24 4 13; 25 19 9; 26 20 18; 27 19 20;1 23; 29 23 22; 30 24 26; 31 26 25; 32 23 26; 33 23 16; 34 27 17; 35 27 26;18; 37 11 22; 38 28 13; 39 28 25; 40 29 16; 41 22 25;NE MATERIAL STARTROPIC CONCRETE17185e+007SON 0.17ITY 23.5616A 1e-0050.05CONCRETENGTH FCU 27579DEFINE MATERIALER PROPERTY AMERICAN6 12 TO 16 28 TO 31 40 PRIS YD 0.35 ZD 0.35

    17 18 21 25 TO 27 34 36 PRIS YD 0.8 ZD 0.2519 20 22 23 38 PRIS YD 0.5 ZD 0.353 35 PRIS YD 0.4 ZD 0.259 41 PRIS YD 0.4 ZD 0.3RIS YD 0.6 ZD 0.35TANTSRIAL CONCRETE ALLORTS5 12 14 21 24 29 FIXEDNE IBC 20030.007 SD1 0.003 S1 0.002 IE 1 RX 3 RZ 3 SCLASS 4WEIGHT 1ER WEIGHT18 21 25 TO 27 32 TO 36 UNI 29.5220 22 TO 24 37 TO 39 41 UNI 2.16R WEIGHT

    GE 3 6 FLOAD 8.39NE WIND LOAD1 WIND 1

    TAAD PRO GENERATED DATA DO NOT MODIFY !!!-7-2010:PARAMS 145.000 KMPH 0 2 1 0 0.000 FT 0.000 FT 0.000 FT 1 -800 M 11.500 M 8.250 M 2.000 0.010 0 -0 0 0.858 1.000 1.000 0.850 0 -0 0.888 0.800 -0.550ND GENERATED DATA BLOCK2.35486 2.35486 2.35592 2.35698 2.35804 2.3591 2.36015 2.3612 2.36225 -6329 2.36433 2.36537 2.36641 2.36744 2.36847 0.646088 HEIG 0 4.572 -8954 4.60708 4.62462 4.64215 4.65969 4.67723 4.69477 4.71231 -2985 4.74739 4.76492 4.78246 4.8 4.82 WIND 2

    TAAD PRO GENERATED DATA DO NOT MODIFY !!!-7-2010:PARAMS 145.000 KMPH 0 2 1 0 0.000 FT 0.000 FT 0.000 FT 1 -

    800 M 11.500 M 8.250 M 2.000 0.010 1 -0 0 0.858 1.000 1.000 0.850 0 -0 0.888 -0.300 0.550ND GENERATED DATA BLOCK-0.592267 -0.592267 -0.914308 HEIG 0 4.8 401 LOADTYPE None TITLE LOAD CASE 1

    LOAD X 1ORM ANALYSISGE2 LOADTYPE None TITLE LOAD CASE 2

    LOAD Z 1ORM ANALYSISGE3 LOADTYPE None TITLE LOAD CASE 3

    WEIGHT Y -1ER LOAD18 21 25 TO 27 32 TO 36 UNI GY -29.52

    : 1

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    16/128

    ProV8i\STAAD\Plugins\METERING BUILDING-1642K.std 09/09/13 07:39:41

    18 21 25 TO 27 32 TO 36 UNI GY -29.52R LOADGE 3 6 FLOAD -8.39 GYER LOAD20 22 23 37 TO 39 41 UNI GY -2.164 LOADTYPE None TITLE LOAD CASE 4

    R LOADGE 3 6 FLOAD -1 GY5 LOADTYPE None TITLE LOAD CASE 5LOAD X 1 TYPE 1 YR 1 66 LOADTYPE None TITLE LOAD CASE 6LOAD -X 1 TYPE 2 YR 1 67 LOADTYPE None TITLE LOAD CASE 7LOAD Z 1 TYPE 1 YR 1 6 ZR 0 1

    8 LOADTYPE None TITLE LOAD CASE 8LOAD -Z 1 TYPE 2 YR 1 6 ZR 1 9RVICE STRESS DESIGN LOAD COMBINATIONSCOMB 101 COMBINATION LOAD CASE 1010 4 1.0COMB 102 COMBINATION LOAD CASE 1020 4 0.75 5 0.75COMB 103 COMBINATION LOAD CASE 1030 4 1.0 6 0.75COMB 104 COMBINATION LOAD CASE 1040 4 1.0 7 0.75COMB 105 COMBINATION LOAD CASE 1050 4 1.0 8 0.75COMB 106 COMBINATION LOAD CASE 1060 4 1.0 5 1.0COMB 107 COMBINATION LOAD CASE 107

    0 4 1.0 6 1.0COMB 108 COMBINATION LOAD CASE 1080 4 1.0 7 1.0COMB 109 COMBINATION LOAD CASE 1090 4 1.0 8 1.0COMB 110 COMBINATION LOAD CASE 1100 4 0.75 5 0.53COMB 111 COMBINATION LOAD CASE 1110 4 1.0 6 0.53COMB 112 COMBINATION LOAD CASE 1120 4 1.0 7 0.53COMB 113 COMBINATION LOAD CASE 1130 4 1.0 8 0.53COMB 114 COMBINATION LOAD CASE 1146 5 1.0COMB 115 COMBINATION LOAD CASE 115

    6 6 1.0COMB 116 COMBINATION LOAD CASE 1166 7 1.0COMB 117 COMBINATION LOAD CASE 1176 8 1.0COMB 118 COMBINATION LOAD CASE 1180 4 0.75 1 1.0COMB 119 COMBINATION LOAD CASE 1190 4 0.75 2 1.0COMB 120 COMBINATION LOAD CASE 1206 1 0.7COMB 121 COMBINATION LOAD CASE 1216 2 0.7RENGTH DESIGN LOAD COMBINATIONSCOMB 201 COMBINATION LOAD CASE 2014

    COMB 202 COMBINATION LOAD CASE 2022 4 1.6COMB 203 COMBINATION LOAD CASE 2032 4 1.6 5 0.8COMB 204 COMBINATION LOAD CASE 2042 4 1.6 6 0.8COMB 205 COMBINATION LOAD CASE 2052 4 1.6 7 0.8COMB 206 COMBINATION LOAD CASE 2062 4 1.6 8 0.8COMB 207 COMBINATION LOAD CASE 2072 4 0.5 5 1.6COMB 208 COMBINATION LOAD CASE 2082 4 0.5 6 1.6COMB 209 COMBINATION LOAD CASE 2092 4 0.5 7 1.6COMB 210 COMBINATION LOAD CASE 210

    : 2

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    17/128

    ProV8i\STAAD\Plugins\METERING BUILDING-1642K.std 09/09/13 07:39:41

    COMB 210 COMBINATION LOAD CASE 2102 4 0.5 8 1.6COMB 211 COMBINATION LOAD CASE 2112 4 1.0 1 1.0COMB 212 COMBINATION LOAD CASE 2122 4 1.0 2 1.0COMB 213 COMBINATION LOAD CASE 2139 5 1.6COMB 214 COMBINATION LOAD CASE 2149 6 1.6COMB 215 COMBINATION LOAD CASE 2159 7 1.6COMB 216 COMBINATION LOAD CASE 2169 8 1.6

    COMB 217 COMBINATION LOAD CASE 2179 1 1.0COMB 218 COMBINATION LOAD CASE 2189 2 1.0ORM ANALYSISLIST 101 TO 121 201 TO 218T CONCRETE DESIGNACI

    8000 ALLIN 420000 ALLC 420000 ALLAIN 20 ALLAIN 16 ALLEC 10 ALLF 0 MEMB 1 TO 6 12 TO 16 28 TO 31 40N 0.01 MEMB 1 TO 6 12 TO 16 28 TO 31 40

    K 0 ALLGN COLUMN 1 TO 6 12 TO 16 28 TO 31 40GN BEAM 7 TO 10 17 TO 27 32 TO 39 41CONCRETE DESIGNFACTORED LOADLIST 101 TO 121T SUPPORT REACTION ALLCTORED LOADLIST 201 TO 218T SUPPORT REACTION ALLT JOINT DISPLACEMENTS ALLSH

    : 3

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    18/128

    PROJECT: JOB NO.: BI-21-00052 SHEET NO.:

    LOCATION: DESIGN BY: AAM DATE: 09/09/2013

    CLIENT: CHECKED BY: SAM APPROVED BY: MAG

    SALES GAS DELIVERY SYSTEM

    RIYADH

    SAUDI ARAMCO

    4.0 COMPUTER OUTPUT FILE 4.0 COMPUTER OUTPUT FILE 4.0 COMPUTER OUTPUT FILE 4.0 COMPUTER OUTPUT FILE 

    DESIGN OF BEAMS & COLUMNSDESIGN OF BEAMS & COLUMNSDESIGN OF BEAMS & COLUMNSDESIGN OF BEAMS & COLUMNS

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    19/128

    Monday, September 09, 2013, 08:0

    PAGE NO. 1

    ****************************************************

    * *

    * STAAD.Pro V8i SELECTseries3 *

    * Version 20.07.08.20 *

    * Proprietary Program of *

    * Bentley Systems, Inc. *

    * Date= SEP 9, 2013 *

    * Time= 7:58: 3 ** *

    * USER ID: Mustang Engineering *

    ****************************************************

    1. STAAD SPACE

    NPUT FILE: METERING BUILDING-1642K.STD

    2. START JOB INFORMATION

    3. ENGINEER DATE 30-MAR-13

    4. END JOB INFORMATION

    5. INPUT WIDTH 79

    6. UNIT METER KN

    7. JOINT COORDINATES8. 1 0 0 0; 2 0 5.8 0; 3 5.75 0 0; 4 5.75 5.8 0; 5 11.5 0 0; 6 11.5 5.8 0

    9. 7 0 1 0; 8 5.75 1 0; 9 11.5 1 0; 11 0 5.8 6; 12 5.75 0 6; 13 5.75 5.8 6

    10. 14 11.5 0 6; 15 11.5 5.8 6; 16 0 1 6; 17 5.75 1 6; 18 11.5 1 6; 19 8.5 1 0

    11. 20 8.5 1 6; 21 0 0 8.25; 22 0 5.8 8.25; 23 0 1 8.25; 24 2.9 0 8.25

    12. 25 2.9 5.8 8.25; 26 2.9 1 8.25; 27 2.9 1 6; 28 2.9 5.8 6; 29 0 0 6

    13. MEMBER INCIDENCES

    14. 1 1 7; 2 3 8; 3 5 9; 4 7 2; 5 8 4; 6 9 6; 7 7 8; 8 8 19; 9 2 4; 10 4 6

    15. 12 12 17; 13 14 18; 14 16 11; 15 17 13; 16 18 15; 17 16 27; 18 17 20; 19 11 28

    16. 20 13 15; 21 7 16; 22 2 11; 23 6 15; 24 4 13; 25 19 9; 26 20 18; 27 19 20

    17. 28 21 23; 29 23 22; 30 24 26; 31 26 25; 32 23 26; 33 23 16; 34 27 17; 35 27 26

    18. 36 9 18; 37 11 22; 38 28 13; 39 28 25; 40 29 16; 41 22 25

    19. DEFINE MATERIAL START

    20. ISOTROPIC CONCRETE

    21. E 2.17185E+007

    22. POISSON 0.17

    23. DENSITY 23.5616

    24. ALPHA 1E-005

    25. DAMP 0.05

    26. TYPE CONCRETE

    27. STRENGTH FCU 27579

    28. END DEFINE MATERIAL

    29. MEMBER PROPERTY AMERICAN

    30. 1 TO 6 12 TO 16 28 TO 31 40 PRIS YD 0.35 ZD 0.35

    31. 7 8 17 18 21 25 TO 27 34 36 PRIS YD 0.8 ZD 0.25

    32. 9 10 19 20 22 23 38 PRIS YD 0.5 ZD 0.35

    33. 32 33 35 PRIS YD 0.4 ZD 0.25

    34. 37 39 41 PRIS YD 0.4 ZD 0.3

    35. 24 PRIS YD 0.6 ZD 0.35

    36. CONSTANTS37. MATERIAL CONCRETE ALL

    38. SUPPORTS

    39. 1 3 5 12 14 21 24 29 FIXED

    40. DEFINE IBC 2003

    Page 1 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    20/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 2

    41. SDS 0.007 SD1 0.003 S1 0.002 IE 1 RX 3 RZ 3 SCLASS 4

    42. SELFWEIGHT 1

    43. MEMBER WEIGHT

    44. 7 8 18 21 25 TO 27 32 TO 36 UNI 29.52

    45. 9 10 20 22 TO 24 37 TO 39 41 UNI 2.16

    46. FLOOR WEIGHT

    **WARNING** about Floor/OneWay Loads/Weights.

    Please note that depending on the shape of the floor you may

    have to break up the FLOOR/ONEWAY LOAD into multiple commands.

    For details please refer to Technical Reference ManualSection 5.32.4 Note 6.

    47. YRANGE 3 6 FLOAD 8.39

    48. DEFINE WIND LOAD

    49. TYPE 1 WIND 1

    50.

    51. ASCE-7-2010:PARAMS 145.000 KMPH 0 2 1 0 0.000 FT 0.000 FT 0.000 FT 1 -

    52. 1 4.800 M 11.500 M 8.250 M 2.000 0.010 0 -

    53. 0 0 0 0 0.858 1.000 1.000 0.850 0 -

    54. 0 0 0 0.888 0.800 -0.550

    55. !> END GENERATED DATA BLOCK

    56. INT 2.35486 2.35486 2.35592 2.35698 2.35804 2.3591 2.36015 2.3612 2.36225 -

    57. 2.36329 2.36433 2.36537 2.36641 2.36744 2.36847 0.646088 HEIG 0 4.572 -

    58. 4.58954 4.60708 4.62462 4.64215 4.65969 4.67723 4.69477 4.71231 -59. 4.72985 4.74739 4.76492 4.78246 4.8 4.8

    60. TYPE 2 WIND 2

    61.

    62. ASCE-7-2010:PARAMS 145.000 KMPH 0 2 1 0 0.000 FT 0.000 FT 0.000 FT 1 -

    63. 1 4.800 M 11.500 M 8.250 M 2.000 0.010 1 -

    64. 0 0 0 0 0.858 1.000 1.000 0.850 0 -

    65. 0 0 0 0.888 -0.300 0.550

    66. !> END GENERATED DATA BLOCK

    67. INT -0.592267 -0.592267 -0.914308 HEIG 0 4.8 40

    68. LOAD 1 LOADTYPE NONE TITLE LOAD CASE 1

    69. IBC LOAD X 1

    70. PERFORM ANALYSIS

    P R O B L E M S T A T I S T I C S

    -----------------------------------

     NUMBER OF JOINTS/MEMBER+ELEMENTS/SUPPORTS = 28/ 40/ 8

    SOLVER USED IS THE OUT-OF-CORE BASIC SOLVER 

    ORIGINAL/FINAL BAND-WIDTH= 17/ 6/ 36 DOF

    TOTAL PRIMARY LOAD CASES = 1, TOTAL DEGREES OF FREEDOM = 120

    SIZE OF STIFFNESS MATRIX = 5 DOUBLE KILO-WORDS

    REQRD/AVAIL. DISK SPACE = 12.1/ 331966.0 MB

    Page 2 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    21/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 3

    ************************************************************

    * IBC 2003 SEISMIC LOAD ALONG X : *

    * CT = 0.016 Cu = 1.700 *

    * TIME PERIODS : *

    * Ta = 0.227 T = 0.479 Tuser = 0.000 *

    * TIME PERIOD USED (T) = 0.386 *

    * LOAD FACTOR = 1.000 ** DESIGN BASE SHEAR = 1.000 X 0.002 X 2614.59 *

    * = 6.10 KN *

    ************************************************************

    71. CHANGE

    72. LOAD 2 LOADTYPE NONE TITLE LOAD CASE 2

    73. IBC LOAD Z 1

    74. PERFORM ANALYSIS

    ************************************************************

    * IBC 2003 SEISMIC LOAD ALONG Z : *

    * CT = 0.016 Cu = 1.700 *

    * TIME PERIODS : *

    * Ta = 0.227 T = 0.499 Tuser = 0.000 *

    * TIME PERIOD USED (T) = 0.386 *

    * LOAD FACTOR = 1.000 *

    * DESIGN BASE SHEAR = 1.000 X 0.002 X 2614.59 *

    * = 6.10 KN *

    ************************************************************

    75. CHANGE

    76. LOAD 3 LOADTYPE NONE TITLE LOAD CASE 3

    77. SELFWEIGHT Y -1

    78. MEMBER LOAD

    79. 7 8 18 21 25 TO 27 32 TO 36 UNI GY -29.52

    80. FLOOR LOAD

    81. YRANGE 3 6 FLOAD -8.39 GY

    82. MEMBER LOAD

    83. 9 10 20 22 23 37 TO 39 41 UNI GY -2.16

    84. LOAD 4 LOADTYPE NONE TITLE LOAD CASE 4

    85. FLOOR LOAD

    Page 3 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    22/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 4

    86. YRANGE 3 6 FLOAD -1 GY

    87. LOAD 5 LOADTYPE NONE TITLE LOAD CASE 5

    88. WIND LOAD X 1 TYPE 1 YR 1 6

    89. LOAD 6 LOADTYPE NONE TITLE LOAD CASE 6

    90. WIND LOAD -X 1 TYPE 2 YR 1 6

    91. LOAD 7 LOADTYPE NONE TITLE LOAD CASE 7

    92. WIND LOAD Z 1 TYPE 1 YR 1 6 ZR 0 1

    93. LOAD 8 LOADTYPE NONE TITLE LOAD CASE 8

    94. WIND LOAD -Z 1 TYPE 2 YR 1 6 ZR 1 9

    95. **SERVICE STRESS DESIGN LOAD COMBINATIONS96. LOAD COMB 101 COMBINATION LOAD CASE 101

    97. 3 1.0 4 1.0

    98. LOAD COMB 102 COMBINATION LOAD CASE 102

    99. 3 1.0 4 0.75 5 0.75

    100. LOAD COMB 103 COMBINATION LOAD CASE 103

    101. 3 1.0 4 1.0 6 0.75

    102. LOAD COMB 104 COMBINATION LOAD CASE 104

    103. 3 1.0 4 1.0 7 0.75

    104. LOAD COMB 105 COMBINATION LOAD CASE 105

    105. 3 1.0 4 1.0 8 0.75

    106. LOAD COMB 106 COMBINATION LOAD CASE 106

    107. 3 1.0 4 1.0 5 1.0

    108. LOAD COMB 107 COMBINATION LOAD CASE 107

    109. 3 1.0 4 1.0 6 1.0110. LOAD COMB 108 COMBINATION LOAD CASE 108

    111. 3 1.0 4 1.0 7 1.0

    112. LOAD COMB 109 COMBINATION LOAD CASE 109

    113. 3 1.0 4 1.0 8 1.0

    114. LOAD COMB 110 COMBINATION LOAD CASE 110

    115. 3 1.0 4 0.75 5 0.53

    116. LOAD COMB 111 COMBINATION LOAD CASE 111

    117. 3 1.0 4 1.0 6 0.53

    118. LOAD COMB 112 COMBINATION LOAD CASE 112

    119. 3 1.0 4 1.0 7 0.53

    120. LOAD COMB 113 COMBINATION LOAD CASE 113

    121. 3 1.0 4 1.0 8 0.53

    122. LOAD COMB 114 COMBINATION LOAD CASE 114

    123. 3 0.6 5 1.0

    124. LOAD COMB 115 COMBINATION LOAD CASE 115

    125. 3 0.6 6 1.0

    126. LOAD COMB 116 COMBINATION LOAD CASE 116

    Page 4 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    23/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 5

    127. 3 0.6 7 1.0

    128. LOAD COMB 117 COMBINATION LOAD CASE 117

    129. 3 0.6 8 1.0

    130. LOAD COMB 118 COMBINATION LOAD CASE 118

    131. 3 1.0 4 0.75 1 1.0

    132. LOAD COMB 119 COMBINATION LOAD CASE 119

    133. 3 1.0 4 0.75 2 1.0

    134. LOAD COMB 120 COMBINATION LOAD CASE 120

    135. 3 0.6 1 0.7

    136. LOAD COMB 121 COMBINATION LOAD CASE 121137. 3 0.6 2 0.7

    138. **STRENGTH DESIGN LOAD COMBINATIONS

    139. LOAD COMB 201 COMBINATION LOAD CASE 201

    140. 3 1.4

    141. LOAD COMB 202 COMBINATION LOAD CASE 202

    142. 3 1.2 4 1.6

    143. LOAD COMB 203 COMBINATION LOAD CASE 203

    144. 3 1.2 4 1.6 5 0.8

    145. LOAD COMB 204 COMBINATION LOAD CASE 204

    146. 3 1.2 4 1.6 6 0.8

    147. LOAD COMB 205 COMBINATION LOAD CASE 205

    148. 3 1.2 4 1.6 7 0.8

    149. LOAD COMB 206 COMBINATION LOAD CASE 206

    150. 3 1.2 4 1.6 8 0.8151. LOAD COMB 207 COMBINATION LOAD CASE 207

    152. 3 1.2 4 0.5 5 1.6

    153. LOAD COMB 208 COMBINATION LOAD CASE 208

    154. 3 1.2 4 0.5 6 1.6

    155. LOAD COMB 209 COMBINATION LOAD CASE 209

    156. 3 1.2 4 0.5 7 1.6

    157. LOAD COMB 210 COMBINATION LOAD CASE 210

    158. 3 1.2 4 0.5 8 1.6

    159. LOAD COMB 211 COMBINATION LOAD CASE 211

    160. 3 1.2 4 1.0 1 1.0

    161. LOAD COMB 212 COMBINATION LOAD CASE 212

    162. 3 1.2 4 1.0 2 1.0

    163. LOAD COMB 213 COMBINATION LOAD CASE 213

    164. 3 0.9 5 1.6

    165. LOAD COMB 214 COMBINATION LOAD CASE 214

    166. 3 0.9 6 1.6

    167. LOAD COMB 215 COMBINATION LOAD CASE 215

    168. 3 0.9 7 1.6

    169. LOAD COMB 216 COMBINATION LOAD CASE 216

    170. 3 0.9 8 1.6

    171. LOAD COMB 217 COMBINATION LOAD CASE 217

    172. 3 0.9 1 1.0

    173. LOAD COMB 218 COMBINATION LOAD CASE 218

    174. 3 0.9 2 1.0

    175. PERFORM ANALYSIS

    176. LOAD LIST 101 TO 121 201 TO 218

    177. START CONCRETE DESIGN

    Page 5 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    24/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 6

    178. CODE ACI

    179. FC 28000 ALL

    180. FYMAIN 420000 ALL

    181. FYSEC 420000 ALL

    182. MAXMAIN 25 ALL

    183. MINMAIN 16 ALL

    184. MINSEC 10 ALL

    185. REINF 0 MEMB 1 TO 6 12 TO 16 28 TO 31 40

    186. RHOMN 0.01 MEMB 1 TO 6 12 TO 16 28 TO 31 40

    187. TRACK 0 ALL188. DESIGN COLUMN 1 TO 6 12 TO 16 28 TO 31 40

    Page 6 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    25/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 7

    ====================================================================

    COLUMN NO. 1 DESIGN PER ACI 318-05 - AXIAL + BENDING

    FY - 420.0 FC - 28.0 MPA, SQRE SIZE - 350.0 X 350.0 MMS, TIED

    ONLY MINIMUM STEEL IS REQUIRED.

    AREA OF STEEL REQUIRED = 1225.0 SQ. MM

    BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI

    ----------------------------------------------------------

    4 - 20 MM 1.026 101 END 0.650

    (PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)

    TIE BAR NUMBER 10 SPACING 320.00 MM

    ====================================================================

    COLUMN NO. 2 DESIGN PER ACI 318-05 - AXIAL + BENDING

    FY - 420.0 FC - 28.0 MPA, SQRE SIZE - 350.0 X 350.0 MMS, TIED

    ONLY MINIMUM STEEL IS REQUIRED.

    AREA OF STEEL REQUIRED = 1225.0 SQ. MM

    BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI

    ----------------------------------------------------------

    4 - 20 MM 1.026 101 END 0.650

    (PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)

    TIE BAR NUMBER 10 SPACING 320.00 MM

    ====================================================================

    COLUMN NO. 3 DESIGN PER ACI 318-05 - AXIAL + BENDING

    FY - 420.0 FC - 28.0 MPA, SQRE SIZE - 350.0 X 350.0 MMS, TIED

    AREA OF STEEL REQUIRED = 1911.0 SQ. MM

    BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI

    ----------------------------------------------------------

    4 - 25 MM 1.603 201 END 0.650

    (PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)

    TIE BAR NUMBER 10 SPACING 320.00 MM

    Page 7 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    26/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 8

    ====================================================================

    COLUMN NO. 4 DESIGN PER ACI 318-05 - AXIAL + BENDING

    FY - 420.0 FC - 28.0 MPA, SQRE SIZE - 350.0 X 350.0 MMS, TIED

    ONLY MINIMUM STEEL IS REQUIRED.

    AREA OF STEEL REQUIRED = 1225.0 SQ. MM

    BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI

    ----------------------------------------------------------

    4 - 20 MM 1.026 101 END 0.650

    (PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)

    TIE BAR NUMBER 10 SPACING 320.00 MM

    ====================================================================

    COLUMN NO. 5 DESIGN PER ACI 318-05 - AXIAL + BENDING

    FY - 420.0 FC - 28.0 MPA, SQRE SIZE - 350.0 X 350.0 MMS, TIED

    ONLY MINIMUM STEEL IS REQUIRED.

    AREA OF STEEL REQUIRED = 1225.0 SQ. MM

    BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI

    ----------------------------------------------------------

    4 - 20 MM 1.026 101 END 0.650

    (PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)

    TIE BAR NUMBER 10 SPACING 320.00 MM

    ====================================================================

    COLUMN NO. 6 DESIGN PER ACI 318-05 - AXIAL + BENDING

    FY - 420.0 FC - 28.0 MPA, SQRE SIZE - 350.0 X 350.0 MMS, TIED

    AREA OF STEEL REQUIRED = 1568.0 SQ. MM

    BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI

    ----------------------------------------------------------

    8 - 16 MM 1.313 207 END 0.650

    (PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)

    TIE BAR NUMBER 10 SPACING 256.00 MM

    Page 8 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    27/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 9

    ====================================================================

    COLUMN NO. 12 DESIGN PER ACI 318-05 - AXIAL + BENDING

    FY - 420.0 FC - 28.0 MPA, SQRE SIZE - 350.0 X 350.0 MMS, TIED

    ONLY MINIMUM STEEL IS REQUIRED.

    AREA OF STEEL REQUIRED = 1225.0 SQ. MM

    BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI

    ----------------------------------------------------------

    4 - 20 MM 1.026 101 END 0.650

    (PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)

    TIE BAR NUMBER 10 SPACING 320.00 MM

    ====================================================================

    COLUMN NO. 13 DESIGN PER ACI 318-05 - AXIAL + BENDING

    FY - 420.0 FC - 28.0 MPA, SQRE SIZE - 350.0 X 350.0 MMS, TIED

    AREA OF STEEL REQUIRED = 1911.0 SQ. MM

    BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI

    ----------------------------------------------------------

    4 - 25 MM 1.603 201 END 0.650

    (PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)

    TIE BAR NUMBER 10 SPACING 320.00 MM

    ====================================================================

    COLUMN NO. 14 DESIGN PER ACI 318-05 - AXIAL + BENDING

    FY - 420.0 FC - 28.0 MPA, SQRE SIZE - 350.0 X 350.0 MMS, TIED

    ONLY MINIMUM STEEL IS REQUIRED.

    AREA OF STEEL REQUIRED = 1225.0 SQ. MM

    BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI

    ----------------------------------------------------------

    4 - 20 MM 1.026 101 END 0.650

    (PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)

    TIE BAR NUMBER 10 SPACING 320.00 MM

    Page 9 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    28/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 10

    ====================================================================

    COLUMN NO. 15 DESIGN PER ACI 318-05 - AXIAL + BENDING

    FY - 420.0 FC - 28.0 MPA, SQRE SIZE - 350.0 X 350.0 MMS, TIED

    ONLY MINIMUM STEEL IS REQUIRED.

    AREA OF STEEL REQUIRED = 1225.0 SQ. MM

    BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI

    ----------------------------------------------------------

    4 - 20 MM 1.026 101 END 0.650

    (PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)

    TIE BAR NUMBER 10 SPACING 320.00 MM

    ====================================================================

    COLUMN NO. 16 DESIGN PER ACI 318-05 - AXIAL + BENDING

    FY - 420.0 FC - 28.0 MPA, SQRE SIZE - 350.0 X 350.0 MMS, TIED

    AREA OF STEEL REQUIRED = 1911.0 SQ. MM

    BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI

    ----------------------------------------------------------

    4 - 25 MM 1.603 209 END 0.650

    (PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)

    TIE BAR NUMBER 10 SPACING 256.00 MM

    ====================================================================

    COLUMN NO. 28 DESIGN PER ACI 318-05 - AXIAL + BENDING

    FY - 420.0 FC - 28.0 MPA, SQRE SIZE - 350.0 X 350.0 MMS, TIED

    ONLY MINIMUM STEEL IS REQUIRED.

    AREA OF STEEL REQUIRED = 1225.0 SQ. MM

    BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI

    ----------------------------------------------------------

    4 - 20 MM 1.026 101 END 0.650

    (PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)

    TIE BAR NUMBER 10 SPACING 320.00 MM

    Page 10 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    29/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 11

    ====================================================================

    COLUMN NO. 29 DESIGN PER ACI 318-05 - AXIAL + BENDING

    FY - 420.0 FC - 28.0 MPA, SQRE SIZE - 350.0 X 350.0 MMS, TIED

    ONLY MINIMUM STEEL IS REQUIRED.

    AREA OF STEEL REQUIRED = 1225.0 SQ. MM

    BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI

    ----------------------------------------------------------

    4 - 20 MM 1.026 101 END 0.650

    (PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)

    TIE BAR NUMBER 10 SPACING 320.00 MM

    ====================================================================

    COLUMN NO. 30 DESIGN PER ACI 318-05 - AXIAL + BENDING

    FY - 420.0 FC - 28.0 MPA, SQRE SIZE - 350.0 X 350.0 MMS, TIED

    ONLY MINIMUM STEEL IS REQUIRED.

    AREA OF STEEL REQUIRED = 1225.0 SQ. MM

    BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI

    ----------------------------------------------------------

    4 - 20 MM 1.026 101 END 0.650

    (PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)

    TIE BAR NUMBER 10 SPACING 320.00 MM

    ====================================================================

    COLUMN NO. 31 DESIGN PER ACI 318-05 - AXIAL + BENDING

    FY - 420.0 FC - 28.0 MPA, SQRE SIZE - 350.0 X 350.0 MMS, TIED

    ONLY MINIMUM STEEL IS REQUIRED.

    AREA OF STEEL REQUIRED = 1225.0 SQ. MM

    BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI

    ----------------------------------------------------------

    4 - 20 MM 1.026 101 END 0.650

    (PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)

    TIE BAR NUMBER 10 SPACING 320.00 MM

    Page 11 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    30/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 12

    ====================================================================

    COLUMN NO. 40 DESIGN PER ACI 318-05 - AXIAL + BENDING

    FY - 420.0 FC - 28.0 MPA, SQRE SIZE - 350.0 X 350.0 MMS, TIED

    ONLY MINIMUM STEEL IS REQUIRED.

    AREA OF STEEL REQUIRED = 1225.0 SQ. MM

    BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI

    ----------------------------------------------------------

    4 - 20 MM 1.026 101 END 0.650

    (PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)

    TIE BAR NUMBER 10 SPACING 320.00 MM

    ********************END OF COLUMN DESIGN RESULTS********************

    189. DESIGN BEAM 7 TO 10 17 TO 27 32 TO 39 41

    Page 12 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    31/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 13

    =====================================================================

    BEAM NO. 7 DESIGN RESULTS - FLEXURE PER CODE ACI 318-05

    LEN - 5750. MM FY - 420. FC - 28. MPA, SIZE - 250. X 800. MMS

    LEVEL HEIGHT BAR INFO FROM TO ANCHOR (MM) (MM) (MM) STA END

    _____________________________________________________________________ 

    1 56. 2 - 16MM 0. 4235. YES NO

    2 744. 2 - 16MM 0. 1076. YES NO

    3 744. 4 - 16MM 3286. 5750. NO YES

    B E A M N O. 7 D E S I G N R E S U L T S - SHEAR 

    AT START SUPPORT - Vu= 53.69 KNS Vc= 235.06 KNS Vs= 0.00 KNSTu= 3.27 KN-MET Tc= 6.5 KN-MET Ts= 0.0 KN-MET LOAD 101

    STIRRUPS ARE NOT REQUIRED.

    AT END SUPPORT - Vu= 92.35 KNS Vc= 161.51 KNS Vs= 0.00 KNS

    Tu= 3.27 KN-MET Tc= 6.5 KN-MET Ts= 0.0 KN-MET LOAD 101

    NO STIRRUPS ARE REQUIRED FOR TORSION.

    REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 372. MM C/C FOR 2133. MM

    ___ 7J____________________ 5750X 250X 800_____________________ 8J____ 

    ||============= ================================||

    | 2No16 H 744. 0.TO 1076 4No16|H 744.3286.TO 5750 |

    | | | | |

    | | | | 7*10c/c372 |

    | | | | |

    | 2No16 H 56. 0.TO 4235 | | | |

    ||====================================================== |

    |___________________________________________________________________________|

    ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ 

    |oo | |oo | |oo | | | | | | | | | |ooo| |ooo| |ooo| |ooo| |ooo|

    | 2#16| 2#16| 2#16| | | | | | | | | 4#16| 4#16| 4#16| 4#16 | 4#1

    | | | | | | | | | | | | | | | | | | | | | | | |

    | | | | | | | | | | | | | | | | | | | | | | | |

    | | | | | | | | | | | | | | | | | | | | | | | |

    | 2#16| 2#16| 2#16| 2#16| 2#16| 2#16| 2#16| 2#16| 2#16| | | | | |

    |oo | |oo | |oo | |oo | |oo | |oo | |oo | |oo | |oo | | | | | | |

    |___| |___| |___| |___| |___| |___| |___| |___| |___| |___| |___| |___|

    Page 13 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    32/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 14

    =====================================================================

    BEAM NO. 8 DESIGN RESULTS - FLEXURE PER CODE ACI 318-05

    LEN - 2750. MM FY - 420. FC - 28. MPA, SIZE - 250. X 800. MMS

    LEVEL HEIGHT BAR INFO FROM TO ANCHOR (MM) (MM) (MM) STA END

    _____________________________________________________________________ 

    1 58. 3 - 20MM 685. 2750. NO YES

    2 739. 2 - 25MM 0. 2106. YES NO

    B E A M N O. 8 D E S I G N R E S U L T S - SHEAR 

    AT START SUPPORT - Vu= 203.31 KNS Vc= 186.64 KNS Vs= 84.44 KNS

    Tu= 19.19 KN-MET Tc= 6.9 KN-MET Ts= 25.6 KN-MET LOAD 201STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 178. MM C/C FOR 633. MM

    ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 5.38 SQ.CM.

    AT END SUPPORT - Vu= 142.63 KNS Vc= 169.19 KNS Vs= 20.98 KNS

    Tu= 19.19 KN-MET Tc= 6.9 KN-MET Ts= 25.6 KN-MET LOAD 201

    STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 219. MM C/C FOR 633. MM

    ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 5.38 SQ.CM.

    ___ 8J____________________ 2749X 250X 800_____________________ 19J____ 

    ||========================================================= |

    | 2No25 H 739. 0.TO 2106 | |

    | | | |

    | 5*10c/c178 | | 4*10c/c219 |

    | | | |

    | 3No20 H 58. 685.TO 2750 | |

    | =========================================================||

    |___________________________________________________________________________|

    ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ 

    |oo | |oo | |oo | |oo | |oo | |oo | |oo | |oo | |oo | | | | | | |

    | 2#25| 2#25| 2#25| 2#25| 2#25| 2#25| 2#25| 2#25| 2#25| | | | | |

    | | | | | | | | | | | | | | | | | | | | | | | |

    | | | | | | | | | | | | | | | | | | | | | | | |

    | | | | | | | | | | | | | | | | | | | | | | | |

    | | | | | | | 3#20| 3#20| 3#20| 3#20| 3#20| 3#20| 3#20| 3#20 | 3#2

    | | | | | | |ooo| |ooo| |ooo| |ooo| |ooo| |ooo| |ooo| |ooo| |ooo|

    |___| |___| |___| |___| |___| |___| |___| |___| |___| |___| |___| |___|

    Page 14 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    33/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 15

    =====================================================================

    BEAM NO. 9 DESIGN RESULTS - FLEXURE PER CODE ACI 318-05

    LEN - 5750. MM FY - 420. FC - 28. MPA, SIZE - 350. X 500. MMS

    LEVEL HEIGHT BAR INFO FROM TO ANCHOR (MM) (MM) (MM) STA END

    _____________________________________________________________________ 

    1 56. 3 - 16MM 0. 4700. YES NO

    2 444. 2 - 16MM 0. 1076. YES NO

    3 444. 4 - 16MM 3956. 5750. NO YES

    B E A M N O. 9 D E S I G N R E S U L T S - SHEAR 

    AT START SUPPORT - Vu= 43.65 KNS Vc= 240.43 KNS Vs= 0.00 KNSTu= 3.03 KN-MET Tc= 6.0 KN-MET Ts= 0.0 KN-MET LOAD 101

    STIRRUPS ARE NOT REQUIRED.

    AT END SUPPORT - Vu= 63.42 KNS Vc= 134.71 KNS Vs= 0.00 KNS

    Tu= 3.03 KN-MET Tc= 6.0 KN-MET Ts= 0.0 KN-MET LOAD 101

    NO STIRRUPS ARE REQUIRED FOR TORSION.

    REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 222. MM C/C FOR 2433. MM

    ___ 2J____________________ 5750X 350X 500_____________________ 4J____ 

    | |

    ||============= =======================||

    | 2No16 H 444. 0.TO 1076 4No16|H 444.3956.TO 5750 |

    | | | | 12*10c/c222 |

    | 3No16 H 56. 0.TO 4700 | | | | |

    ||============================================================= |

    | |

    |___________________________________________________________________________|

    _________ _________ _________ _________ _________ _________ 

    | | | | | | | | | | | |

    | oo | | | | | | | | oooo | | oooo |

    | 2#16 | | | | | | | | 4#16 | | 4#16 |

    | | | | | | | | | | | |

    | 3#16 | | 3#16 | | 3#16 | | 3#16 | | 3#16 | | |

    | ooo | | ooo | | ooo | | ooo | | ooo | | |

    | | | | | | | | | | | |

    |_________| |_________| |_________| |_________| |_________| |_________|

    Page 15 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    34/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 16

    =====================================================================

    BEAM NO. 10 DESIGN RESULTS - FLEXURE PER CODE ACI 318-05

    LEN - 5750. MM FY - 420. FC - 28. MPA, SIZE - 350. X 500. MMS

    LEVEL HEIGHT BAR INFO FROM TO ANCHOR (MM) (MM) (MM) STA END

    _____________________________________________________________________ 

    1 56. 3 - 16MM 820. 5169. NO NO

    2 444. 4 - 16MM 0. 1555. YES NO

    3 444. 2 - 16MM 4435. 5750. NO YES

    B E A M N O. 10 D E S I G N R E S U L T S - SHEAR 

    AT START SUPPORT - Vu= 63.71 KNS Vc= 134.32 KNS Vs= 0.00 KNSTu= 2.09 KN-MET Tc= 6.0 KN-MET Ts= 0.0 KN-MET LOAD 101

    NO STIRRUPS ARE REQUIRED FOR TORSION.

    REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 222. MM C/C FOR 2433. MM

    AT END SUPPORT - Vu= 43.36 KNS Vc= 185.99 KNS Vs= 0.00 KNS

    Tu= 2.09 KN-MET Tc= 6.0 KN-MET Ts= 0.0 KN-MET LOAD 101

    STIRRUPS ARE NOT REQUIRED.

    ___ 4J____________________ 5750X 350X 500_____________________ 6J____ 

    | |

    ||=================== =================||

    | 4No16 H 444.| 0.TO 1555 2No16 H 444.4435.TO 5750 |

    | 12*10c/c222 | | | |

    | 3No16 H 56. 820.TO 5169 |

    | =========================================================== |

    | |

    |___________________________________________________________________________|

    _________ _________ _________ _________ _________ _________ 

    | | | | | | | | | | | |

    | oooo | | oooo | | | | | | oo | | oo |

    | 4#16 | | 4#16 | | | | | | 2#16 | | 2#16 |

    | | | | | | | | | | | |

    | | | 3#16 | | 3#16 | | 3#16 | | 3#16 | | |

    | | | ooo | | ooo | | ooo | | ooo | | |

    | | | | | | | | | | | |

    |_________| |_________| |_________| |_________| |_________| |_________|

    Page 16 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    35/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 17

    =====================================================================

    BEAM NO. 17 DESIGN RESULTS - FLEXURE PER CODE ACI 318-05

    LEN - 2900. MM FY - 420. FC - 28. MPA, SIZE - 250. X 800. MMS

    LEVEL HEIGHT BAR INFO FROM TO ANCHOR (MM) (MM) (MM) STA END

    _____________________________________________________________________ 

    1 56. 2 - 16MM 0. 2900. YES YES

    2 744. 2 - 16MM 0. 1322. YES NO

    B E A M N O. 17 D E S I G N R E S U L T S - SHEAR 

    AT START SUPPORT - Vu= 25.46 KNS Vc= 222.33 KNS Vs= 0.00 KNS

    Tu= 4.17 KN-MET Tc= 6.4 KN-MET Ts= 0.0 KN-MET LOAD 101STIRRUPS ARE NOT REQUIRED.

    AT END SUPPORT - Vu= 18.78 KNS Vc= 157.95 KNS Vs= 0.00 KNS

    Tu= 4.17 KN-MET Tc= 6.4 KN-MET Ts= 0.0 KN-MET LOAD 101

    STIRRUPS ARE NOT REQUIRED.

    ___ 16J____________________ 2900X 250X 800_____________________ 27J____ 

    ||================================= |

    | 2No16 H 744. 0.TO 1322 |

    | |

    | |

    | |

    | 2No16 H 56. 0.TO 2900 |

    ||=========================================================================||

    |___________________________________________________________________________|

    ___ ___ ___ ___ ___ ___ 

    |oo | |oo | |oo | | | | | | |

    | 2#16 | 2#16 | 2#16 | | | | | |

    | | | | | | | | | | | |

    | | | | | | | | | | | |

    | | | | | | | | | | | |

    | 2#16 | 2#16 | 2#16 | 2#16 | 2#16 | 2#1

    |oo | |oo | |oo | |oo | |oo | |oo |

    |___| |___| |___| |___| |___| |___|

    Page 17 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    36/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 18

    =====================================================================

    BEAM NO. 18 DESIGN RESULTS - FLEXURE PER CODE ACI 318-05

    LEN - 2750. MM FY - 420. FC - 28. MPA, SIZE - 250. X 800. MMS

    LEVEL HEIGHT BAR INFO FROM TO ANCHOR (MM) (MM) (MM) STA END

    _____________________________________________________________________ 

    1 58. 3 - 20MM 447. 2750. NO YES

    2 742. 3 - 20MM 0. 2006. YES NO

    B E A M N O. 18 D E S I G N R E S U L T S - SHEAR 

    AT START SUPPORT - Vu= 174.21 KNS Vc= 190.98 KNS Vs= 41.30 KNS

    Tu= 22.75 KN-MET Tc= 6.8 KN-MET Ts= 30.3 KN-MET LOAD 209STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 183. MM C/C FOR 633. MM

    ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 6.38 SQ.CM.

    AT END SUPPORT - Vu= 122.20 KNS Vc= 168.30 KNS Vs= 0.00 KNS

    Tu= 22.75 KN-MET Tc= 6.8 KN-MET Ts= 30.3 KN-MET LOAD 209

    STIRRUPS ARE REQUIRED FOR TORSION.

    REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 216. MM C/C FOR 633. MM

    ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 6.38 SQ.CM.

    ___ 17J____________________ 2749X 250X 800_____________________ 20J____ 

    ||====================================================== |

    | 3No20 H 742.| 0.TO 2006| |

    | | | | |

    | 5*10c/c183 | | | 4*10c/c216 |

    | | | | |

    | 3No20 H| 58. 447.TO 2750 |

    | ===============================================================||

    |___________________________________________________________________________|

    ___ ___ ___ ___ ___ ___ 

    |ooo| |ooo| |ooo| |ooo| | | | |

    | 3#20 | 3#20 | 3#20 | 3#20 | | | |

    | | | | | | | | | | | |

    | | | | | | | | | | | |

    | | | | | | | | | | | |

    | | | 3#20 | 3#20 | 3#20 | 3#20 | 3#2

    | | |ooo| |ooo| |ooo| |ooo| |ooo||___| |___| |___| |___| |___| |___|

    Page 18 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    37/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 19

    =====================================================================

    BEAM NO. 19 DESIGN RESULTS - FLEXURE PER CODE ACI 318-05

    LEN - 2900. MM FY - 420. FC - 28. MPA, SIZE - 350. X 500. MMS

    LEVEL HEIGHT BAR INFO FROM TO ANCHOR (MM) (MM) (MM) STA END

    _____________________________________________________________________ 

    1 56. 3 - 16MM 0. 2900. YES YES

    2 444. 2 - 16MM 0. 1080. YES NO

    B E A M N O. 19 D E S I G N R E S U L T S - SHEAR 

    AT START SUPPORT - Vu= 55.33 KNS Vc= 193.76 KNS Vs= 0.00 KNS

    Tu= 4.01 KN-MET Tc= 6.0 KN-MET Ts= 0.0 KN-MET LOAD 101STIRRUPS ARE NOT REQUIRED.

    AT END SUPPORT - Vu= 0.68 KNS Vc= 129.75 KNS Vs= 0.00 KNS

    Tu= 4.01 KN-MET Tc= 6.0 KN-MET Ts= 0.0 KN-MET LOAD 101

    STIRRUPS ARE NOT REQUIRED.

    ___ 11J____________________ 2900X 350X 500_____________________ 28J____ 

    | |

    ||=========================== |

    | 2No16 H 444. 0.TO 1080 |

    | |

    | 3No16 H 56. 0.TO 2900 |

    ||=========================================================================||

    | |

    |___________________________________________________________________________|

    _________ _________ _________ _________ _________ _________ 

    | | | | | | | | | | | |

    | oo | | oo | | | | | | | | |

    | 2#16 | | 2#16 | | | | | | | | |

    | | | | | | | | | | | |

    | 3#16 | | 3#16 | | 3#16 | | 3#16 | | 3#16 | | 3#16 |

    | ooo | | ooo | | ooo | | ooo | | ooo | | ooo |

    | | | | | | | | | | | |

    |_________| |_________| |_________| |_________| |_________| |_________|

    Page 19 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    38/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 20

    =====================================================================

    BEAM NO. 20 DESIGN RESULTS - FLEXURE PER CODE ACI 318-05

    LEN - 5750. MM FY - 420. FC - 28. MPA, SIZE - 350. X 500. MMS

    LEVEL HEIGHT BAR INFO FROM TO ANCHOR (MM) (MM) (MM) STA END

    _____________________________________________________________________ 

    1 56. 3 - 16MM 829. 5160. NO NO

    2 444. 4 - 16MM 0. 2034. YES NO

    3 444. 2 - 16MM 4435. 5750. NO YES

    B E A M N O. 20 D E S I G N R E S U L T S - SHEAR 

    AT START SUPPORT - Vu= 64.44 KNS Vc= 134.00 KNS Vs= 0.00 KNSTu= 1.96 KN-MET Tc= 6.0 KN-MET Ts= 0.0 KN-MET LOAD 101

    NO STIRRUPS ARE REQUIRED FOR TORSION.

    REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 222. MM C/C FOR 2433. MM

    AT END SUPPORT - Vu= 42.63 KNS Vc= 191.59 KNS Vs= 0.00 KNS

    Tu= 1.96 KN-MET Tc= 6.0 KN-MET Ts= 0.0 KN-MET LOAD 101

    STIRRUPS ARE NOT REQUIRED.

    ___ 13J____________________ 5750X 350X 500_____________________ 15J____ 

    | |

    ||========================= =================||

    | 4No16 H 444.| 0.TO 2034| 2No16 H 444.4435.TO 5750 |

    | 12*10c/c222 | | | | | |

    | 3No16 H 56.|829.TO 5160 |

    | =========================================================== |

    | |

    |___________________________________________________________________________|

    _________ _________ _________ _________ _________ _________ 

    | | | | | | | | | | | |

    | oooo | | oooo | | | | | | oo | | oo |

    | 4#16 | | 4#16 | | | | | | 2#16 | | 2#16 |

    | | | | | | | | | | | |

    | | | 3#16 | | 3#16 | | 3#16 | | 3#16 | | |

    | | | ooo | | ooo | | ooo | | ooo | | |

    | | | | | | | | | | | |

    |_________| |_________| |_________| |_________| |_________| |_________|

    Page 20 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    39/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 21

    =====================================================================

    BEAM NO. 21 DESIGN RESULTS - FLEXURE PER CODE ACI 318-05

    LEN - 6000. MM FY - 420. FC - 28. MPA, SIZE - 250. X 800. MMS

    LEVEL HEIGHT BAR INFO FROM TO ANCHOR (MM) (MM) (MM) STA END

    _____________________________________________________________________ 

    1 56. 3 - 16MM 0. 5426. YES NO

    2 744. 3 - 16MM 0. 1097. YES NO

    3 744. 3 - 16MM 4153. 6000. NO YES

    B E A M N O. 21 D E S I G N R E S U L T S - SHEAR 

    AT START SUPPORT - Vu= 74.43 KNS Vc= 293.13 KNS Vs= 0.00 KNSTu= 0.80 KN-MET Tc= 6.6 KN-MET Ts= 0.0 KN-MET LOAD 101

    STIRRUPS ARE NOT REQUIRED.

    AT END SUPPORT - Vu= 85.55 KNS Vc= 220.32 KNS Vs= 0.00 KNS

    Tu= 0.93 KN-MET Tc= 6.7 KN-MET Ts= 0.0 KN-MET LOAD 108

    NO STIRRUPS ARE REQUIRED FOR TORSION.

    REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 372. MM C/C FOR 2258. MM

    ___ 7J____________________ 6000X 250X 800_____________________ 16J____ 

    ||============ =======================||

    | 3No16 H 744. 0.TO 1097 3No16 H 744.4153.TO 6000 |

    | | | | |

    | | | 8*10c/c372 |

    | | | | |

    | 3No16 H 56. 0.TO 5426 | | | |

    ||=================================================================== |

    |___________________________________________________________________________|

    ___ ___ ___ ___ ___ ___ 

    |ooo| | | | | | | |ooo| |ooo|

    | 3#16 | | | | | | | 3#16 | 3#1

    | | | | | | | | | | | |

    | | | | | | | | | | | |

    | | | | | | | | | | | |

    | 3#16 | 3#16 | 3#16 | 3#16 | 3#16 | |

    |ooo| |ooo| |ooo| |ooo| |ooo| | |

    |___| |___| |___| |___| |___| |___|

    Page 21 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    40/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 22

    =====================================================================

    BEAM NO. 22 DESIGN RESULTS - FLEXURE PER CODE ACI 318-05

    LEN - 6000. MM FY - 420. FC - 28. MPA, SIZE - 350. X 500. MMS

    LEVEL HEIGHT BAR INFO FROM TO ANCHOR (MM) (MM) (MM) STA END

    _____________________________________________________________________ 

    1 56. 3 - 16MM 0. 5410. YES NO

    2 444. 2 - 16MM 0. 1097. YES NO

    3 444. 3 - 16MM 4153. 6000. NO YES

    B E A M N O. 22 D E S I G N R E S U L T S - SHEAR 

    AT START SUPPORT - Vu= 53.02 KNS Vc= 187.06 KNS Vs= 0.00 KNSTu= 0.67 KN-MET Tc= 6.0 KN-MET Ts= 0.0 KN-MET LOAD 101

    STIRRUPS ARE NOT REQUIRED.

    AT END SUPPORT - Vu= 62.42 KNS Vc= 138.95 KNS Vs= 0.00 KNS

    Tu= 0.67 KN-MET Tc= 6.0 KN-MET Ts= 0.0 KN-MET LOAD 101

    NO STIRRUPS ARE REQUIRED FOR TORSION.

    REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 222. MM C/C FOR 2558. MM

    ___ 2J____________________ 6000X 350X 500_____________________ 11J____ 

    | |

    ||============ =======================||

    | 2No16 H 444. 0.TO 1097 3No16|H 444.4153.TO 6000 |

    | | | | 13*10c/c222 |

    | 3No16 H 56. 0.TO 5410 | | | | | | |

    ||=================================================================== |

    | |

    |___________________________________________________________________________|

    _________ _________ _________ _________ _________ _________ 

    | | | | | | | | | | | |

    | oo | | | | | | | | ooo | | ooo |

    | 2#16 | | | | | | | | 3#16 | | 3#16 |

    | | | | | | | | | | | |

    | 3#16 | | 3#16 | | 3#16 | | 3#16 | | 3#16 | | |

    | ooo | | ooo | | ooo | | ooo | | ooo | | |

    | | | | | | | | | | | |

    |_________| |_________| |_________| |_________| |_________| |_________|

    Page 22 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    41/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 23

    =====================================================================

    BEAM NO. 23 DESIGN RESULTS - FLEXURE PER CODE ACI 318-05

    LEN - 6000. MM FY - 420. FC - 28. MPA, SIZE - 350. X 500. MMS

    LEVEL HEIGHT BAR INFO FROM TO ANCHOR (MM) (MM) (MM) STA END

    _____________________________________________________________________ 

    1 58. 2 - 20MM 0. 5563. YES NO

    2 444. 2 - 16MM 0. 1097. YES NO

    3 444. 3 - 16MM 4653. 6000. NO YES

    B E A M N O. 23 D E S I G N R E S U L T S - SHEAR 

    AT START SUPPORT - Vu= 74.82 KNS Vc= 168.61 KNS Vs= 0.00 KNSTu= 0.20 KN-MET Tc= 6.1 KN-MET Ts= 0.0 KN-MET LOAD 201

    NO STIRRUPS ARE REQUIRED FOR TORSION.

    REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 221. MM C/C FOR 2558. MM

    AT END SUPPORT - Vu= 61.58 KNS Vc= 147.98 KNS Vs= 0.00 KNS

    Tu= 0.07 KN-MET Tc= 6.1 KN-MET Ts= 0.0 KN-MET LOAD 104

    NO STIRRUPS ARE REQUIRED FOR TORSION.

    REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 221. MM C/C FOR 2558. MM

    ___ 6J____________________ 6000X 350X 500_____________________ 15J____ 

    | |

    ||============ =================||

    | 2No16 H 444. 0.TO 1097 3No16 H 444.4653.TO 6000 |

    | 13*10c/c221 | 13*10c/c221 |

    | 2No20 H 58. 0.TO 5563 | | | | |

    ||===================================================================== |

    | |

    |___________________________________________________________________________|

    _________ _________ _________ _________ _________ _________ 

    | | | | | | | | | | | |

    | oo | | | | | | | | ooo | | ooo |

    | 2#16 | | | | | | | | 3#16 | | 3#16 |

    | | | | | | | | | | | |

    | 2#20 | | 2#20 | | 2#20 | | 2#20 | | 2#20 | | |

    | oo | | oo | | oo | | oo | | oo | | |

    | | | | | | | | | | | ||_________| |_________| |_________| |_________| |_________| |_________|

    Page 23 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    42/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 24

    =====================================================================

    BEAM NO. 24 DESIGN RESULTS - FLEXURE PER CODE ACI 318-05

    LEN - 6000. MM FY - 420. FC - 28. MPA, SIZE - 350. X 600. MMS

    LEVEL HEIGHT BAR INFO FROM TO ANCHOR (MM) (MM) (MM) STA END

    _____________________________________________________________________ 

    1 61. 2 - 25MM 0. 6000. YES YES

    2 544. 2 - 16MM 0. 597. YES NO

    3 544. 3 - 16MM 4653. 6000. NO YES

    B E A M N O. 24 D E S I G N R E S U L T S - SHEAR 

    AT START SUPPORT - Vu= 90.41 KNS Vc= 215.90 KNS Vs= 0.00 KNSTu= 0.47 KN-MET Tc= 7.9 KN-MET Ts= 0.0 KN-MET LOAD 104

    NO STIRRUPS ARE REQUIRED FOR TORSION.

    REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 270. MM C/C FOR 2458. MM

    AT END SUPPORT - Vu= 120.05 KNS Vc= 285.48 KNS Vs= 0.00 KNS

    Tu= 0.86 KN-MET Tc= 7.8 KN-MET Ts= 0.0 KN-MET LOAD 201

    NO STIRRUPS ARE REQUIRED FOR TORSION.

    REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 270. MM C/C FOR 2458. MM

    ___ 4J____________________ 6000X 350X 600_____________________ 13J____ 

    | |

    ||====== =================||

    | 2No16 H 544. 0.TO 597 3No16 H|544.4653.TO|6000 |

    | 11*10c/c270 | 11*10c/c270 | |

    | 2No25 H 61. 0.TO 6000 | | | | | |

    ||=========================================================================||

    | |

    |___________________________________________________________________________|

    _________ _________ _________ _________ _________ _________ 

    | | | | | | | | | | | |

    | oo | | | | | | | | ooo | | ooo |

    | 2#16 | | | | | | | | 3#16 | | 3#16 |

    | | | | | | | | | | | |

    | 2#25 | | 2#25 | | 2#25 | | 2#25 | | 2#25 | | 2#25 |

    | oo | | oo | | oo | | oo | | oo | | oo |

    | | | | | | | | | | | ||_________| |_________| |_________| |_________| |_________| |_________|

    Page 24 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    43/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 25

    =====================================================================

    BEAM NO. 25 DESIGN RESULTS - FLEXURE PER CODE ACI 318-05

    LEN - 3000. MM FY - 420. FC - 28. MPA, SIZE - 250. X 800. MMS

    LEVEL HEIGHT BAR INFO FROM TO ANCHOR (MM) (MM) (MM) STA END

    _____________________________________________________________________ 

    1 58. 3 - 20MM 0. 2826. YES NO

    2 744. 3 - 16MM 1528. 3000. NO YES

    B E A M N O. 25 D E S I G N R E S U L T S - SHEAR 

    AT START SUPPORT - Vu= 72.43 KNS Vc= 159.69 KNS Vs= 0.00 KNS

    Tu= 8.21 KN-MET Tc= 6.9 KN-MET Ts= 10.9 KN-MET LOAD 201STIRRUPS ARE REQUIRED FOR TORSION.

    REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 219. MM C/C FOR 758. MM

    ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 2.30 SQ.CM.

    AT END SUPPORT - Vu= 145.09 KNS Vc= 300.89 KNS Vs= 0.00 KNS

    Tu= 8.21 KN-MET Tc= 6.9 KN-MET Ts= 10.9 KN-MET LOAD 201

    STIRRUPS ARE REQUIRED FOR TORSION.

    REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 219. MM C/C FOR 758. MM

    ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 2.30 SQ.CM.

    ___ 19J____________________ 3000X 250X 800_____________________ 9J____ 

    | =====================================||

    | 3No16 H 744.1528.TO 3000 | |

    | | | | | |

    | 5*10c/c219 | | 5*10c/c219 |

    | | | | | |

    | 3No20 H 58. 0.TO 2826 | | | | |

    ||====================================================================== |

    |___________________________________________________________________________|

    ___ ___ ___ ___ ___ ___ 

    | | | | | | |ooo| |ooo| |ooo|

    | | | | | | | 3#16 | 3#16 | 3#1

    | | | | | | | | | | | |

    | | | | | | | | | | | |

    | | | | | | | | | | | |

    | 3#20 | 3#20 | 3#20 | 3#20 | 3#20 | ||ooo| |ooo| |ooo| |ooo| |ooo| | |

    |___| |___| |___| |___| |___| |___|

    Page 25 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    44/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 26

    =====================================================================

    BEAM NO. 26 DESIGN RESULTS - FLEXURE PER CODE ACI 318-05

    LEN - 3000. MM FY - 420. FC - 28. MPA, SIZE - 250. X 800. MMS

    LEVEL HEIGHT BAR INFO FROM TO ANCHOR (MM) (MM) (MM) STA END

    _____________________________________________________________________ 

    1 58. 3 - 20MM 0. 2834. YES NO

    2 744. 3 - 16MM 1528. 3000. NO YES

    B E A M N O. 26 D E S I G N R E S U L T S - SHEAR 

    AT START SUPPORT - Vu= 65.06 KNS Vc= 159.82 KNS Vs= 0.00 KNS

    Tu= 8.13 KN-MET Tc= 6.8 KN-MET Ts= 10.8 KN-MET LOAD 209STIRRUPS ARE REQUIRED FOR TORSION.

    REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 219. MM C/C FOR 758. MM

    ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 2.28 SQ.CM.

    AT END SUPPORT - Vu= 127.34 KNS Vc= 298.45 KNS Vs= 0.00 KNS

    Tu= 8.13 KN-MET Tc= 6.8 KN-MET Ts= 10.8 KN-MET LOAD 209

    STIRRUPS ARE REQUIRED FOR TORSION.

    REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 219. MM C/C FOR 758. MM

    ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 2.28 SQ.CM.

    ___ 20J____________________ 3000X 250X 800_____________________ 18J____ 

    | =====================================||

    | 3No16 H 744.1528.TO 3000 | |

    | | | | | |

    | 5*10c/c219 | | 5*10c/c219 |

    | | | | | |

    | 3No20 H 58. 0.TO 2834 | | | | |

    ||====================================================================== |

    |___________________________________________________________________________|

    ___ ___ ___ ___ ___ ___ 

    | | | | | | |ooo| |ooo| |ooo|

    | | | | | | | 3#16 | 3#16 | 3#1

    | | | | | | | | | | | |

    | | | | | | | | | | | |

    | | | | | | | | | | | |

    | 3#20 | 3#20 | 3#20 | 3#20 | 3#20 | ||ooo| |ooo| |ooo| |ooo| |ooo| | |

    |___| |___| |___| |___| |___| |___|

    Page 26 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    45/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 27

    =====================================================================

    BEAM NO. 27 DESIGN RESULTS - FLEXURE PER CODE ACI 318-05

    LEN - 6000. MM FY - 420. FC - 28. MPA, SIZE - 250. X 800. MMS

    LEVEL HEIGHT BAR INFO FROM TO ANCHOR (MM) (MM) (MM) STA END

    _____________________________________________________________________ 

    1 56. 4 - 16MM 0. 6000. YES YES

    2 744. 2 - 16MM 0. 597. YES NO

    3 744. 2 - 16MM 5153. 6000. NO YES

    B E A M N O. 27 D E S I G N R E S U L T S - SHEAR 

    AT START SUPPORT - Vu= 77.43 KNS Vc= 163.20 KNS Vs= 0.00 KNSTu= 0.02 KN-MET Tc= 6.3 KN-MET Ts= 0.0 KN-MET LOAD 101

    NO STIRRUPS ARE REQUIRED FOR TORSION.

    REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 372. MM C/C FOR 2258. MM

    AT END SUPPORT - Vu= 77.17 KNS Vc= 163.20 KNS Vs= 0.00 KNS

    Tu= 0.02 KN-MET Tc= 6.3 KN-MET Ts= 0.0 KN-MET LOAD 101

    NO STIRRUPS ARE REQUIRED FOR TORSION.

    REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 372. MM C/C FOR 2258. MM

    ___ 19J____________________ 6000X 250X 800_____________________ 20J____ 

    ||====== ==========||

    | 2No16|H 744. 0.TO 597 2No16 H 744.5153.TO 6000 |

    | | | | | |

    | 8*10c/c372 8*10c/c372| |

    | | | | | |

    | 4No16|H 56. 0.TO 6000 | | |

    ||=========================================================================||

    |___________________________________________________________________________|

    ___ ___ ___ ___ ___ ___ 

    |oo | | | | | | | | | |oo |

    | 2#16 | | | | | | | | | 2#1

    | | | | | | | | | | | |

    | | | | | | | | | | | |

    | | | | | | | | | | | |

    | 4#16 | 4#16 | 4#16 | 4#16 | 4#16 | 4#1

    |ooo| |ooo| |ooo| |ooo| |ooo| |ooo||___| |___| |___| |___| |___| |___|

    Page 27 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    46/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 28

    =====================================================================

    BEAM NO. 32 DESIGN RESULTS - FLEXURE PER CODE ACI 318-05

    LEN - 2900. MM FY - 420. FC - 28. MPA, SIZE - 250. X 400. MMS

    LEVEL HEIGHT BAR INFO FROM TO ANCHOR (MM) (MM) (MM) STA END

    _____________________________________________________________________ 

    1 56. 2 - 16MM 0. 2655. YES NO

    2 344. 2 - 16MM 0. 1080. YES NO

    3 344. 2 - 16MM 1458. 2900. NO YES

    B E A M N O. 32 D E S I G N R E S U L T S - SHEAR 

    AT START SUPPORT - Vu= 35.48 KNS Vc= 84.71 KNS Vs= 0.00 KNSTu= 0.44 KN-MET Tc= 2.6 KN-MET Ts= 0.0 KN-MET LOAD 101

    NO STIRRUPS ARE REQUIRED FOR TORSION.

    REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 172. MM C/C FOR 1108. MM

    AT END SUPPORT - Vu= 35.17 KNS Vc= 86.04 KNS Vs= 0.00 KNS

    Tu= 0.44 KN-MET Tc= 2.6 KN-MET Ts= 0.0 KN-MET LOAD 101

    NO STIRRUPS ARE REQUIRED FOR TORSION.

    REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 172. MM C/C FOR 1108. MM

    ___ 23J____________________ 2900X 250X 400_____________________ 26J____ 

    | |

    ||=========================== =====================================||

    | 2No16|H 344. 0.TO 1080 | 2No16 H 344.1458.TO 2900 | |

    | 8*10c/c172 | | | | | | | 8*10c/c172 |

    | 2No16|H 56. 0.TO 2655 | | | | | | | |

    ||==================================================================== |

    | |

    |___________________________________________________________________________|

    _________ _________ _________ _________ _________ _________ 

    | | | | | | | | | | | |

    | oo | | oo | | | | oo | | oo | | oo |

    | 2#16 | | 2#16 | | | | 2#16 | | 2#16 | | 2#16 |

    | | | | | | | | | | | |

    | 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 | | |

    | oo | | oo | | oo | | oo | | oo | | |

    | | | | | | | | | | | ||_________| |_________| |_________| |_________| |_________| |_________|

    Page 28 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    47/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 29

    =====================================================================

    BEAM NO. 33 DESIGN RESULTS - FLEXURE PER CODE ACI 318-05

    LEN - 2250. MM FY - 420. FC - 28. MPA, SIZE - 250. X 400. MMS

    LEVEL HEIGHT BAR INFO FROM TO ANCHOR (MM) (MM) (MM) STA END

    _____________________________________________________________________ 

    1 56. 2 - 16MM 201. 1393. NO NO

    2 344. 2 - 16MM 0. 1347. YES NO

    3 344. 2 - 16MM 810. 2250. NO YES

    B E A M N O. 33 D E S I G N R E S U L T S - SHEAR 

    AT START SUPPORT - Vu= 13.99 KNS Vc= 76.37 KNS Vs= 0.00 KNSTu= 0.31 KN-MET Tc= 2.6 KN-MET Ts= 0.0 KN-MET LOAD 101

    STIRRUPS ARE NOT REQUIRED.

    AT END SUPPORT - Vu= 35.94 KNS Vc= 72.78 KNS Vs= 0.00 KNS

    Tu= 0.31 KN-MET Tc= 2.6 KN-MET Ts= 0.0 KN-MET LOAD 101

    NO STIRRUPS ARE REQUIRED FOR TORSION.

    REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 172. MM C/C FOR 783. MM

    ___ 23J____________________ 2250X 250X 400_____________________ 16J____ 

    | |

    ||=========================================================================||

    | 2No16 H 344. 0.TO 1347 2No16 H 344. 810.TO 2250 |

    | | 6*10c/c172 |

    | 2No16 H 56. 201.TO 1393 | |

    | ========================================== |

    | |

    |___________________________________________________________________________|

    _________ _________ _________ _________ _________ _________ 

    | | | | | | | | | | | |

    | oo | | oo | | oo | | oo | | oo | | oo |

    | 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |

    | | | | | | | | | | | |

    | | | 2#16 | | 2#16 | | 2#16 | | | | |

    | | | oo | | oo | | oo | | | | |

    | | | | | | | | | | | |

    |_________| |_________| |_________| |_________| |_________| |_________|

    Page 29 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    48/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 30

    =====================================================================

    BEAM NO. 34 DESIGN RESULTS - FLEXURE PER CODE ACI 318-05

    LEN - 2850. MM FY - 420. FC - 28. MPA, SIZE - 250. X 800. MMS

    LEVEL HEIGHT BAR INFO FROM TO ANCHOR (MM) (MM) (MM) STA END

    _____________________________________________________________________ 

    1 56. 2 - 16MM 0. 1251. YES NO

    2 744. 4 - 16MM 282. 2850. NO YES

    B E A M N O. 34 D E S I G N R E S U L T S - SHEAR 

    AT START SUPPORT - Vu= 42.69 KNS Vc= 165.26 KNS Vs= 0.00 KNS

    Tu= 7.39 KN-MET Tc= 6.4 KN-MET Ts= 9.9 KN-MET LOAD 209STIRRUPS ARE REQUIRED FOR TORSION.

    REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 219. MM C/C FOR 683. MM

    ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 2.07 SQ.CM.

    AT END SUPPORT - Vu= 98.81 KNS Vc= 159.66 KNS Vs= 0.00 KNS

    Tu= 7.39 KN-MET Tc= 6.4 KN-MET Ts= 9.9 KN-MET LOAD 209

    STIRRUPS ARE REQUIRED FOR TORSION.

    REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 219. MM C/C FOR 683. MM

    ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 2.07 SQ.CM.

    ___ 27J____________________ 2850X 250X 800_____________________ 17J____ 

    | ====================================================================||

    | 4No16 H 744.|282.TO 2850 |

    | | | | | |

    | 5*10c/c219 | | | 5*10c/c219 |

    | | | | | |

    | 2No16 H 56.| 0.TO 1251| |

    ||================================ |

    |___________________________________________________________________________|

    ___ ___ ___ ___ ___ ___ 

    | | |ooo| |ooo| |ooo| |ooo| |ooo|

    | | | 4#16 | 4#16 | 4#16 | 4#16 | 4#1

    | | | | | | | | | | | |

    | | | | | | | | | | | |

    | | | | | | | | | | | |

    | 2#16 | 2#16 | 2#16 | | | | | ||oo | |oo | |oo | | | | | | |

    |___| |___| |___| |___| |___| |___|

    Page 30 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    49/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 31

    =====================================================================

    BEAM NO. 35 DESIGN RESULTS - FLEXURE PER CODE ACI 318-05

    LEN - 2250. MM FY - 420. FC - 28. MPA, SIZE - 250. X 400. MMS

    LEVEL HEIGHT BAR INFO FROM TO ANCHOR (MM) (MM) (MM) STA END

    _____________________________________________________________________ 

    1 56. 2 - 16MM 0. 1855. YES NO

    2 344. 2 - 16MM 0. 597. YES NO

    3 344. 2 - 16MM 810. 2250. NO YES

    B E A M N O. 35 D E S I G N R E S U L T S - SHEAR 

    AT START SUPPORT - Vu= 18.32 KNS Vc= 75.29 KNS Vs= 0.00 KNSTu= 0.63 KN-MET Tc= 2.5 KN-MET Ts= 0.0 KN-MET LOAD 101

    STIRRUPS ARE NOT REQUIRED.

    AT END SUPPORT - Vu= 31.60 KNS Vc= 76.90 KNS Vs= 0.00 KNS

    Tu= 0.63 KN-MET Tc= 2.5 KN-MET Ts= 0.0 KN-MET LOAD 101

    NO STIRRUPS ARE REQUIRED FOR TORSION.

    REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 172. MM C/C FOR 783. MM

    ___ 27J____________________ 2250X 250X 400_____________________ 26J____ 

    | |

    ||=================== ================================================||

    | 2No16 H 344. 0.TO 597 2No16 H 344. 810.TO 2250 | | |

    | | | | 6*10c/c172 |

    | 2No16 H 56. 0.TO 1855 | | | | |

    ||============================================================= |

    | |

    |___________________________________________________________________________|

    _________ _________ _________ _________ _________ _________ 

    | | | | | | | | | | | |

    | oo | | oo | | oo | | oo | | oo | | oo |

    | 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |

    | | | | | | | | | | | |

    | 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 | | |

    | oo | | oo | | oo | | oo | | oo | | |

    | | | | | | | | | | | |

    |_________| |_________| |_________| |_________| |_________| |_________|

    Page 31 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    50/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 32

    =====================================================================

    BEAM NO. 36 DESIGN RESULTS - FLEXURE PER CODE ACI 318-05

    LEN - 6000. MM FY - 420. FC - 28. MPA, SIZE - 250. X 800. MMS

    LEVEL HEIGHT BAR INFO FROM TO ANCHOR (MM) (MM) (MM) STA END

    _____________________________________________________________________ 

    1 58. 2 - 20MM 0. 5556. YES NO

    2 744. 3 - 16MM 0. 1097. YES NO

    3 744. 3 - 16MM 4153. 6000. NO YES

    B E A M N O. 36 D E S I G N R E S U L T S - SHEAR 

    AT START SUPPORT - Vu= 81.06 KNS Vc= 207.94 KNS Vs= 0.00 KNSTu= 0.27 KN-MET Tc= 6.8 KN-MET Ts= 0.0 KN-MET LOAD 209

    NO STIRRUPS ARE REQUIRED FOR TORSION.

    REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 371. MM C/C FOR 2258. MM

    AT END SUPPORT - Vu= 77.11 KNS Vc= 293.87 KNS Vs= 0.00 KNS

    Tu= 0.09 KN-MET Tc= 6.6 KN-MET Ts= 0.0 KN-MET LOAD 101

    STIRRUPS ARE NOT REQUIRED.

    ___ 9J____________________ 6000X 250X 800_____________________ 18J____ 

    ||============ =======================||

    | 3No16|H 744. 0.TO 1097 3No16 H 744.4153.TO 6000 |

    | | | | |

    | 8*10c/c371 |

    | | | | |

    | 2No20|H 58. 0.TO 5556 |

    ||===================================================================== |

    |___________________________________________________________________________|

    ___ ___ ___ ___ ___ ___ 

    |ooo| | | | | | | |ooo| |ooo|

    | 3#16 | | | | | | | 3#16 | 3#1

    | | | | | | | | | | | |

    | | | | | | | | | | | |

    | | | | | | | | | | | |

    | 2#20 | 2#20 | 2#20 | 2#20 | 2#20 | |

    |oo | |oo | |oo | |oo | |oo | | |

    |___| |___| |___| |___| |___| |___|

    Page 32 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    51/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 33

    =====================================================================

    BEAM NO. 37 DESIGN RESULTS - FLEXURE PER CODE ACI 318-05

    LEN - 2250. MM FY - 420. FC - 28. MPA, SIZE - 300. X 400. MMS

    LEVEL HEIGHT BAR INFO FROM TO ANCHOR (MM) (MM) (MM) STA END

    _____________________________________________________________________ 

    1 56. 2 - 16MM 1720. 2250. NO YES

    2 344. 3 - 16MM 0. 2250. YES YES

    B E A M N O. 37 D E S I G N R E S U L T S - SHEAR 

    AT START SUPPORT - Vu= 36.87 KNS Vc= 86.44 KNS Vs= 0.00 KNS

    Tu= 7.17 KN-MET Tc= 3.4 KN-MET Ts= 9.6 KN-MET LOAD 201STIRRUPS ARE REQUIRED FOR TORSION.

    REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 132. MM C/C FOR 783. MM

    ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 2.11 SQ.CM.

    AT END SUPPORT - Vu= 12.83 KNS Vc= 90.19 KNS Vs= 0.00 KNS

    Tu= 7.17 KN-MET Tc= 3.4 KN-MET Ts= 9.6 KN-MET LOAD 201

    STIRRUPS ARE REQUIRED FOR TORSION.

    REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 132. MM C/C FOR 783. MM

    ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 2.11 SQ.CM.

    ___ 11J____________________ 2250X 300X 400_____________________ 22J____ 

    | |

    ||=========================================================================||

    | 3No16 H 344. 0.TO 2250 | | | | |

    | 7*10c/c132 | 7*10c/c132 | |

    | 2No16 H |56.1720.TO 2250 |

    | =================||

    | |

    |___________________________________________________________________________|

    ___________ ___________ ___________ ___________ ___________ 

    | | | | | | | | | |

    | ooo | | ooo | | ooo | | ooo | | ooo |

    | 3#16 | | 3#16 | | 3#16 | | 3#16 | | 3#16 |

    | | | | | | | | | |

    | | | | | | | | | 2#16 |

    | | | | | | | | | oo || | | | | | | | | |

    |___________| |___________| |___________| |___________| |___________|

    Page 33 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    52/128

    Monday, September 09, 2013, 08:0

    STAAD SPACE -- PAGE NO. 34

    =====================================================================

    BEAM NO. 38 DESIGN RESULTS - FLEXURE PER CODE ACI 318-05

    LEN - 2850. MM FY - 420. FC - 28. MPA, SIZE - 350. X 500. MMS

    LEVEL HEIGHT BAR INFO FROM TO ANCHOR (MM) (MM) (MM) STA END

    _____________________________________________________________________ 

    1 56. 3 - 16MM 0. 1813. YES NO

    2 444. 4 - 16MM 947. 2850. NO YES

    B E A M N O. 38 D E S I G N R E S U L T S - SHEAR 

    AT START SUPPORT - Vu= 35.09 KNS Vc= 132.07 KNS Vs= 0.00 KNS

    Tu= 9.04 KN-MET Tc= 6.0 KN-MET Ts= 12.1 KN-MET LOAD 201STIRRUPS ARE REQUIRED FOR TORSION.

    REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 169. MM C/C FOR 983. MM

    ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 2.10 SQ.CM.

    AT END SUPPORT - Vu= 88.16 KNS Vc= 134.75 KNS Vs= 0.00 KNS

    Tu= 9.04 KN-MET Tc= 6.0 KN-MET Ts= 12.1 KN-MET LOAD 201

    STIRRUPS ARE REQUIRED FOR TORSION.

    REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.

    PROVIDE 10 MM 2-LEGGED STIRRUPS AT 169. MM C/C FOR 983. MM

    ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 2.10 SQ.CM.

    ___ 28J____________________ 2850X 350X 500_____________________ 13J____ 

    | |

    | ==================================================||

    | 4No16 H 444. 947.TO 2850 |

    | 7*10c/c169 | | | 7*10c/c169 |

    | 3No16 H 56. 0.TO 1813 | | | |

    ||=============================================== |

    | |

    |___________________________________________________________________________|

    _________ _________ _________ _________ _________ 

    | | | | | | | | | |

    | | | | | oooo | | oooo | | oooo |

    | | | | | 4#16 | | 4#16 | | 4#16 |

    | | | | | | | | | |

    | 3#16 | | 3#16 | | 3#16 | | | | |

    | ooo | | ooo | | ooo | | | | || | | | | | | | | |

    |_________| |_________| |_________| |_________| |_________|

    Page 34 o:\SProV8i\STAAD\Plugins\METERING BUILDING-1642K.anl

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    53/128

  • 8/18/2019 Design calculation report - Pipe rack - and foundation

    54/128

    Mond