DESIGN AND FEA OF A 3D PRINTED DETECTOR WINDOW FRAME W. Tizzano * , Diamond Light Source, Didcot, United Kingdom Abstract The purpose of the project was to design and simulate a window assembly to be used in GISAX/GIWAX 1 experi- ments. The window lies between the sample and the WAXS 2 detector, a modified, in-vacuum detector, with modules re- moved to allow scattered radiation to pass through to a SAXS 3 detector positioned downstream. The window uses 75 μm thick Kapton ® HN film and given the size, pressure and the short distance to the sensors, it was necessary to support it on a frame. To avoid any information loss from shadowing of the detector, a frame was designed so that shadows will be pro- jected into the gaps between the detector modules. The geometry was such that DMLS 4 was an effective way of pro- ducing the item. Given the slenderness of the structure and the forces it supports, the material approaches or exceeds its yield point, so a bilinear, isotropic, hardening material model was chosen; moreover, large deflections were enabled. Also, the contacts were modelled with augmented Lagrange fric- tional formulation. All these assumptions made the analysis strongly non-linear. INTRODUCTION I22 is a non-crystalline diffraction beamline for physical and life sciences that records simultaneously both SAXS and WAXS [1]. A recent upgrade project made GISAX/GIWAX experiments possible. Figure 1: I22 Layout. I22 is structured as follows (Fig.1): the beam coming from the BCO 5 hits the sample, and the diffracted light goes through a nosecone and is recorded by a 2D in vacuum WAXS detector; the above mentioned detector has some missing modules on the bottom right (Fig.2), allowing part of the radiation to pass through a snout and a camera tube, so the SAXS scattering can be recorded as well, by a detector * [email protected] 1 Grazing Incidence Small/Wide Angle X-ray scattering 2 Wide Angle X-ray Scattering 3 Small Angle X-ray Scattering 4 Digital Metal Laser Sintering 5 Beam Conditioning Optics at a distance that can vary up to 10 m [2] from the sample; three beamstops prevent the direct and reflected beam, and the glare from hitting the detector damaging it. Figure 2: PILATUS3 2M-DLS-L [3]. WINDOW DESIGN The PILATUS3 2M-DLS-L is an in-vacuum detector, so it was needed to design a window to isolate it from the atmosphere. A 75 μm thick Kapton ® HN film was used, because of its transparency to X-ray and low scattering [4]. However, given the area of the window (5.8 × 10 4 mm 2 ), the force generated by the differential pressure between the two sides of the film was considerable (5.8 kN); for this reason it was necessary to support the Kapton film, or it would have deformed too much, and eventually would have broken. Nonetheless, any support frame would project a shadow on the detector, and some information would be lost. How- ever, the detector is made up of multiple modules, with gaps between them; the horizontal gaps are 17 pixels tall, and the vertical ones are 7 pixels wide. Since the pixels are square, and have a size of 172 μm 2 , the gaps sizes are 2.9 mm and 1.2 mm, respectively. Hence, it was decided to design a sup- port frame consisting in different ribs positioned and angled in such a way that, given a specific relative position between the sample and the detector, the shadow would be projected into the gaps (Fig. 3); in this way no information would be lost. A rib section was drawn in PTC Creo, and all the necessary constraints were chosen so that in the software the ribs would adapt to the sample position, until this was fixed and the design finalised. 9th Edit. of the Mech. Eng. Des. of Synchrotron Radiat. Equip. and Instrum. Conf. MEDSI2016, Barcelona, Spain JACoW Publishing ISBN: 978-3-95450-188-5 doi:10.18429/JACoW-MEDSI2016-TUPE18 Calculation, Simulation & FEA Methods System Simulation and Design Animation TUPE18 201 Content from this work may be used under the terms of the CC BY 3.0 licence (© 2016). Any distribution of this work must maintain attribution to the author(s), title of the work, publisher, and DOI.

Transcript of Design and FEA of a 3D Printed Detector Window …DESIGN AND FEA OF A 3D PRINTED DETECTOR WINDOW...

Page 1: Design and FEA of a 3D Printed Detector Window …DESIGN AND FEA OF A 3D PRINTED DETECTOR WINDOW FRAME W. Tizzano , Diamond Light Source, Didcot, United Kingdom Abstract The purpose

DESIGN AND FEA OF A 3D PRINTED DETECTOR WINDOW FRAMEW. Tizzano∗, Diamond Light Source, Didcot, United Kingdom

AbstractThe purpose of the project was to design and simulate

a window assembly to be used in GISAX/GIWAX1 experi-ments. The window lies between the sample and theWAXS2detector, a modified, in-vacuum detector, with modules re-moved to allow scattered radiation to pass through to aSAXS3 detector positioned downstream. The window uses75 µm thick Kapton® HN film and given the size, pressureand the short distance to the sensors, it was necessary tosupport it on a frame.To avoid any information loss from shadowing of the

detector, a frame was designed so that shadows will be pro-jected into the gaps between the detector modules. Thegeometry was such that DMLS4 was an effective way of pro-ducing the item. Given the slenderness of the structure andthe forces it supports, the material approaches or exceeds itsyield point, so a bilinear, isotropic, hardeningmaterial modelwas chosen; moreover, large deflections were enabled. Also,the contacts were modelled with augmented Lagrange fric-tional formulation. All these assumptions made the analysisstrongly non-linear.

INTRODUCTIONI22 is a non-crystalline diffraction beamline for physical

and life sciences that records simultaneously both SAXS andWAXS [1]. A recent upgrade project made GISAX/GIWAXexperiments possible.

Figure 1: I22 Layout.

I22 is structured as follows (Fig.1): the beam comingfrom the BCO5 hits the sample, and the diffracted light goesthrough a nosecone and is recorded by a 2D in vacuumWAXS detector; the above mentioned detector has somemissing modules on the bottom right (Fig.2), allowing partof the radiation to pass through a snout and a camera tube, sothe SAXS scattering can be recorded as well, by a detector

[email protected] Grazing Incidence Small/Wide Angle X-ray scattering2 Wide Angle X-ray Scattering3 Small Angle X-ray Scattering4 Digital Metal Laser Sintering5 Beam Conditioning Optics

at a distance that can vary up to 10m [2] from the sample;three beamstops prevent the direct and reflected beam, andthe glare from hitting the detector damaging it.

Figure 2: PILATUS3 2M-DLS-L [3].

WINDOW DESIGNThe PILATUS3 2M-DLS-L is an in-vacuum detector, so

it was needed to design a window to isolate it from theatmosphere. A 75 µm thick Kapton® HN film was used,because of its transparency to X-ray and low scattering [4].However, given the area of the window (≈5.8 × 104 mm2),the force generated by the differential pressure between thetwo sides of the film was considerable (≈5.8 kN); for thisreason it was necessary to support the Kapton film, or itwould have deformed too much, and eventually would havebroken.Nonetheless, any support frame would project a shadow

on the detector, and some information would be lost. How-ever, the detector is made up of multiple modules, with gapsbetween them; the horizontal gaps are 17 pixels tall, and thevertical ones are 7 pixels wide. Since the pixels are square,and have a size of 172 µm2, the gaps sizes are 2.9mm and1.2mm, respectively. Hence, it was decided to design a sup-port frame consisting in different ribs positioned and angledin such a way that, given a specific relative position betweenthe sample and the detector, the shadow would be projectedinto the gaps (Fig. 3); in this way no information would belost.

A rib sectionwas drawn in PTCCreo, and all the necessaryconstraints were chosen so that in the software the ribs wouldadapt to the sample position, until this was fixed and thedesign finalised.

9th Edit. of the Mech. Eng. Des. of Synchrotron Radiat. Equip. and Instrum. Conf. MEDSI2016, Barcelona, Spain JACoW PublishingISBN: 978-3-95450-188-5 doi:10.18429/JACoW-MEDSI2016-TUPE18

Calculation, Simulation & FEA MethodsSystem Simulation and Design Animation

TUPE18201

Cont

entf

rom

this

wor

km

aybe

used

unde

rthe

term

soft

heCC

BY3.

0lic

ence

(©20

16).

Any

distr

ibut

ion

ofth

isw

ork

mus

tmai

ntai

nat

tribu

tion

toth

eau

thor

(s),

title

ofth

ew

ork,

publ

isher

,and

DO

I.

Page 2: Design and FEA of a 3D Printed Detector Window …DESIGN AND FEA OF A 3D PRINTED DETECTOR WINDOW FRAME W. Tizzano , Diamond Light Source, Didcot, United Kingdom Abstract The purpose

TITLE

DRGNo.

JDCBA

4

3

2

1

DRG.

PRA

CTIC

E TO

B.S

. 888

8 TH

IRD

ANGL

E PR

OJEC

TION

TOLE

RANC

ING

UNLE

SS O

THER

WIS

E ST

ATED

TO

BS E

N 22

768-

1:19

93 m

ALL

DIM

ENSI

ONS

IN m

m U

NLES

S OT

HERW

ISE

STAT

ED

SHEET

5

6

7

8

E F G H K

REV.

ORIGINATOR/DATE DRGSTATUS

2016

DIA

MON

D LI

GHT

SOUR

CE L

TD©

No

part

of th

is d

raw

ing

may

be

repr

oduc

ed, s

tore

d or

tran

smitt

ed b

y el

ectro

nic

or o

ther

mea

ns e

xcep

t with

the

prio

r writ

ten

perm

issi

on o

f Dia

mon

d Li

ght S

ourc

e Lt

d. N

or m

ay th

is d

raw

ing

be u

sed

for a

ny p

urpo

se o

ther

than

that

it w

as s

uppl

ied

for.

THISREVISION

DRNDATE

-----/--/--

DIAMOND LIGHT SOURCE LTD.DIAMOND HOUSE

HARWELL SCIENCE ANDINNOVATION CAMPUS,

DIDCOT, OXFORDSHIRE,OX11 0DE

CHKDATE

-----/--/--

APPDDATE

-----/--/-- ---- --/--/--

PDMLink PRT0001 1 OF 1

Detector ModuleGap

Rib WAXS Diffraction

Shadow

Sample

Beam

Figure 3: Ribs generation.

Since the resulting geometry was quite complex, and thevolume of material was very small compared to the totalvolume of the part, traditional machining techniques wouldhave been very expensive, so we decided to use an additivemanufacturing technique (DMLS).Among the ones available for this particular manufac-

turing technique, the material selected was stainless steel1.4542, due to its mechanical properties (Table 1), and itsbehaviour in vacuum.

Table 1: SS 1.4542 Mechanical Properties [5]

Property Unit Heat TreatedTensile strength MPa 1040 ± 60Yield point (Rp 0.2%) MPa 430 ± 30Elongation at break % 15E modulus GPa 170 ± 30

FINITE ELEMENTS ANALYSISGiven the slenderness of the structure, and the big loads

applied to it, it was decided to run an FEA to check beforemanufacturing that the design was adequate.

SetupSince the thickness of the Kapton film was very small

compared to the other two dimensions, this element wasmodelled with shell elements and the mechanical propertiesused are summarised in Table 2:

Table 2: Kapton® HN Mechanical Properties [6]

Property Unit Heat TreatedTensile strength MPa 231Yield point at 3% MPa 69Elongation at break % 72E modulus GPa 2.5

The contact between the window and the support framewas modelled with an Augmented Lagrange frictional for-mulation, which reduces the sensitivity of the result to thechoice of the contact stiffness, compared to a pure penaltymethod; in this way, the converged solution will have less

penetration, hence being more accurate, at a cost of moreiterations to reach convergence [7].The Kapton film would deform a lot, and the displace-

ments would be large compared to its thickness, so that theforce generated by the pressure differential would change di-rection; for this reason it was necessary to enable the Ansyslarge deflections option [8].A preliminary analysis confirmed that both the Kapton

film would go beyond the yield point and the steel framewould approach it, so to model these materials as linearelastic was not considered appropriate. To take into accountthe plastic deformation without increasing too much thecomplexity of the simulation, a bilinear isotropic hardeningmodel was chosen (Fig. 4).

2 4 6

·10−3

200

400

Strain ε

Stressσ[M

Pa]

Figure 4: Bilinear Isotropic Hardening.

The Kapton film was meshed using quadrilaters, and thesteel structure using tets (Fig. 5). The mesh quality was ade-quate (Fig. 6). Frictionless supports were used to constrainthe Kapton film and the steel structure, and the load was apressure evenly distributed on the Kapton film.

Figure 5: Mesh detail.

ResultsThe shape of the ribs and the non-linear contact required

a fine mesh to reach convergence (minimum size of theelements 1.5mm), and this was refined even more to 1mmand then 0.8mm to check that the solution was not sensitiveto the mesh size; neither the stress nor the displacementssensibly changed by modifying the mesh.The results showed that the support frame would not de-

form sensibly (Fig. 7); there is a point in the structure where

9th Edit. of the Mech. Eng. Des. of Synchrotron Radiat. Equip. and Instrum. Conf. MEDSI2016, Barcelona, Spain JACoW PublishingISBN: 978-3-95450-188-5 doi:10.18429/JACoW-MEDSI2016-TUPE18

TUPE18202

Cont

entf

rom

this

wor

km

aybe

used

unde

rthe

term

soft

heCC

BY3.

0lic

ence

(©20

16).

Any

distr

ibut

ion

ofth

isw

ork

mus

tmai

ntai

nat

tribu

tion

toth

eau

thor

(s),

title

ofth

ew

ork,

publ

isher

,and

DO

I.

Calculation, Simulation & FEA MethodsSystem Simulation and Design Animation

Page 3: Design and FEA of a 3D Printed Detector Window …DESIGN AND FEA OF A 3D PRINTED DETECTOR WINDOW FRAME W. Tizzano , Diamond Light Source, Didcot, United Kingdom Abstract The purpose

0.5 0.6 0.7 0.8 0.90

50

100

Percento

fvolum

e Tet10 Quad4

Figure 6: Element quality.

the stress is beyond the yield point, but it is a constrainedsharp corner under compressive load, so this is a numeri-cal singularity [9]; other than that, the most stressed pointis below the yield point (Fig. 8). The displacements werenot excessive for the intended use, as the structure and theKapton window are far from the detector modules, and thestructure does not deform enough to affect the shape of theshadows and make them fall outside the gaps between themodules.

Figure 7: Displacements.

Figure 8: Stress.

FUTURE WORKThe parts were manufactured and assembled (Fig. 9), and

they went through a pressure test to check that there wereno leaks or visible damage.

A visual examination did not highlight any noticeablepermanent deformation so the window is now operative (Fig.10); a test is planned to measure stress and strain, so theresults can be compared to the simulated ones, to validatethem.

Figure 9: Assembled window (without Kapton film).

Figure 10: Window in operation.

CONCLUSIONA window frame was designed for use in GISAX/GIWAX

and manufactured with an additive manufacturing process,only after an FEA confirmed the ability of the design to copewith the loads. It is now in use on the beamline.

REFERENCES[1] Diamond Light Source,

http://www.diamond.ac.uk/Beamlines

9th Edit. of the Mech. Eng. Des. of Synchrotron Radiat. Equip. and Instrum. Conf. MEDSI2016, Barcelona, Spain JACoW PublishingISBN: 978-3-95450-188-5 doi:10.18429/JACoW-MEDSI2016-TUPE18

Calculation, Simulation & FEA MethodsSystem Simulation and Design Animation

TUPE18203

Cont

entf

rom

this

wor

km

aybe

used

unde

rthe

term

soft

heCC

BY3.

0lic

ence

(©20

16).

Any

distr

ibut

ion

ofth

isw

ork

mus

tmai

ntai

nat

tribu

tion

toth

eau

thor

(s),

title

ofth

ew

ork,

publ

isher

,and

DO

I.

Page 4: Design and FEA of a 3D Printed Detector Window …DESIGN AND FEA OF A 3D PRINTED DETECTOR WINDOW FRAME W. Tizzano , Diamond Light Source, Didcot, United Kingdom Abstract The purpose

[2] A. Marshall, “Upgrading a Transmission SAX/WAXBeamlineto Allow High Quality GISAX/GIWAX Experiments for SoftMatter Thin Films”, presented at MEDSI’16, Barcelona, Spain,Sep. 2016, paper THAA04.

[3] DECTRIS PILATUS3 2M-DLS-L Detector System, TechnicalSpecification and Operating Procedure, Version V1.0.

[4] M. Antimonov et al., “Large-area kapton X-ray windows”, inProc. of SPIE - The International Society for Optical Engi-neering., vol. 9588, 95880F, SPIE, Advances in X-Ray/EUVOptics and Components X, San Diego, United States, 11-12Aug. DOI: 10.1117/12.2193680.

[5] 3D Alchemy,https://www.3d-alchemy.co.uk/assets/datasheets/3d-Alchemy-Stainless%20Steel%201-4542%20-%2001_13.pdf

[6] Dupont,http://www.dupont.com/products-and-services/membranes-films/polyimide-films/brands/kapton-polyimide-film/products/kapton-hn.html

[7] Ansys Blog,http://www.ansys-blog.com/what-are-the-differences-between-the-contact-formulations

[8] E. Madenci and I. Guven, “Nonlinearity”, in The Finite Ele-ment Method and Applications in Engineering Using ANSYS®,Springer US, 2015, pp. 18–19.

[9] J. Dundurs andM. S. Lee, “Stress concentration at a sharp edgein contact problems”, Elasticity, vol. 2, Issue 2, pp. 109-112,Jun. 1972.

9th Edit. of the Mech. Eng. Des. of Synchrotron Radiat. Equip. and Instrum. Conf. MEDSI2016, Barcelona, Spain JACoW PublishingISBN: 978-3-95450-188-5 doi:10.18429/JACoW-MEDSI2016-TUPE18

TUPE18204

Cont

entf

rom

this

wor

km

aybe

used

unde

rthe

term

soft

heCC

BY3.

0lic

ence

(©20

16).

Any

distr

ibut

ion

ofth

isw

ork

mus

tmai

ntai

nat

tribu

tion

toth

eau

thor

(s),

title

ofth

ew

ork,

publ

isher

,and

DO

I.

Calculation, Simulation & FEA MethodsSystem Simulation and Design Animation