© 2004 Inovonics Wireless - Document #02962C Data Concentrator and Communicator Installation Guide Introduction The Data Concentrator and Communicator (DCC) is installed at the submetering site’s head-end location to collect data from the transmitters using the FA403 receiver. It can communicate with the Read/Bill/Collect service using a modem, or with an onsite technician’s computer using a serial port. This allows the service technician to easily make changes to the site information in the DCC, as well as to perform site data entry, data retrieval and trouble-shooting. Inovonics Contact Information If you have any problems with this installation, contact Inovonics techical support: E-mail: [email protected] Phone: (800) 782-2709 Figure 1 TapWatch® System Hardware DCC FA403 Receiver ACC640 Outdoor Enclosure FA5570 Repeater FA5200-Series Transmitter

description

DCC Install Man

Transcript of Dcc install manual

Page 1: Dcc install manual

© 2004 Inovonics Wireless - Document #02962C

Data Concentrator and Communicator

Installation Guide

IntroductionThe Data Concentrator and Communicator (DCC) is installed at the submetering site’s head-end location to collect data from the transmitters using the FA403 receiver. It can communicate with the Read/Bill/Collect service using a modem, or with an onsite technician’s computer using a serial port. This allows the service technician to easily make changes to the site information in the DCC, as well as to perform site data entry, data retrieval and trouble-shooting.

Inovonics Contact Information

If you have any problems with this installation, contact Inovonics techical support:

• E-mail: [email protected]

• Phone: (800) 782-2709

Figure 1 TapWatch® System Hardware

DCCFA403 ReceiverACC640 Outdoor Enclosure

FA5570 Repeater FA5200-Series Transmitter

Page 2: Dcc install manual

DCC Installation Instructions

2 © 2004 Inovonics Wireless- Document #02962 C

DCC Installation Instructions

Note: Use the DCC Installation Diagram on page 3 with these instructions to install the Data Concentrator and Communicator.

1. Using the anchors and screws provided, mount the FA403 in a building where the temperature will remain within 32° to 140°F (0° to 60°C), non-condensing

• Typically, the higher the FA403 is mounted, the better the RF reception. The FA403 is generally mounted at a height of six to seven feet.

Caution: Neither the FA403 or the DCC should ever be installed at floor level.

2. Using the anchors and screws provided, mount the DCC within 100 feet of the FA403, in a location near phone lines and a standard 120 VAC wall outlet.

3. Connect the FA403 to the DCC using 4-conductor, 22 gauge, unshielded wire with a maximum length of 100 feet.

4. Connect the phone line from the screw terminals on a hardwired wall bracket to the terminal blocks on the DCC.

• The phone line should be connected to the telephone wall outlet using the screw terminals. The RJ11 plug-in phone connector is provided for easy access to the phone line during future on-site maintenance.

5. Use 18 or 20-guage wire to connect 14 VAC power to the DCC with the provided transformer.

• Circuit protection is built into the DCC. There is no need for any additional power strip protection.

6. Use the provided screw to secure the transformer to the outlet.

Note: Telephone and power connections should be as mechanically robust as possible, and protected from accidental disconnection.

Caution: Wiring should exit through the back of the DCC, be cut to length, and stapled neatly to the wall to reduce the possibility of personal injury or equipment damage.

Page 3: Dcc install manual

DCC Installation Diagram

© 2004 Inovonics Wireless - Document #02962C 3

DCC Installation Diagram

Figure 2 DCC Installation Diagram

Table 1: LED Descriptions

Receiver Data Lit when receiving data from the FA403.

Receive Remote

Lit when receiving data via the serial connector or modem.

Transmit DataLit when transmitting data via the serial connector or modem.

Ring IndicatorPulses when the DCC is being called and has not answered.

Modem Status Lit when the modem is operational.

Modem Connect

Lit when the modem is in use.

Power Lit when the DCC is energized.

VSGND OUT

IN

FA403 Serial Receiver Data Connection

FA403Maximum FA403 wire run: 100 ft.

DB9 Serial ConnectorConnects PC to the DCC. Uses RS232C cable with DB9 connectors.Maximum wire run: 25 ft.

RJ11 Jack

PowerTransformer: 120 VAC to 14 VACMaximum power wire run: 100 ft.

Phone LineNote: Tip / ring order does not matter

Page 4: Dcc install manual

Information Supplied to the User

4 © 2004 Inovonics Wireless- Document #02962 C

Information Supplied to the UserThis equipment complies with Part 68 of the FCC rules. On the modem card is a label that contains, among other information, the FCC registration number and Ringer Equivalence Number (REN) for this equipment. If requested, this information must be provided to the telephone company.

The REN is used to determine the quantity of devices which may be connected to the telephone line. Excessive REN's on the telephone line may result in the devices not ringing in response to an incoming call. In most, but not all areas, the sum of the REN's should not exceed five (5.0). To be certain of the number of devices that may be connected to the line, as determine by the total REN's, contact the telephone company to determine the maximum REN for the calling area.

If the terminal equipment (DCC5800) causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice isn't practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC is you believe it is necessary.

The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make the necessary modifications in order to maintain uninterrupted service.

If trouble is experienced with this equipment (DCC5800), please contact the following for repair and/or warranty information.

Inovonics Wireless Corporation, 315 CTC Blvd, Louisville, CO 80027, Phone 800.782.2709If the trouble is causing harm to the telephone network, the telephone company may request that you remove the equipment from the network until the problem is resolved.

Inovonics Wireless must make any necessary repairs to modem portion of this equipment in order to maintain valid FCC registration. Do not attempt to repair or service your modem, return it to Inovonics Wireless.

No repairs can be performed by the customer or user.

This equipment cannot be used on public coin service provided by the telephone company. Connection to Party Line Service is subject to state tariffs.

Use of Attested Plugs and Jacks:

Inovonics attests that the network interface plugs or jacks used on this equipment comply with and will continue to comply with the mechanical requirements specified in Part 68, Subpart F, specifically the dimensions, tolerances, and metallic plating requirements. The compliance of these connectors will be assured by purchase specifications and incoming inspections. Documentation of such specifications and/or inspections will be provided to the FCC within 30 days of their request for same.

Inovonics Submetering Products WarrantyInovonics Wireless Corporation (“Inovonics”) warrants its Products (“Product” or “Products”) to conform to its own specifications and to be free of defects in materials and workmanship under normal use for a period of fourteen (14) months from the date of manufacture. Within the warranty period Inovonics Corporation will repair or replace, at its option, all or any part of the warranted product. Inovonics will not be responsible for dismantling and/or reinstallation charges. To exercise the warranty, the User must be given a Return Material Authorization Number (“RMA”) by Inovonics. Details of shipment will be arranged at that time.

This warranty does not apply in cases of improper installation, misuse, damage due to lightning or water, failure to follow installation and operating instructions, alteration, abuse, accident or tampering, and repair by anyone other than Inovonics.

This warranty is exclusive and expressly in lieu of all other warranties, obligations or liabilities, whether written, oral, express, or implied, including any warranty of merchantability or fitness for a particular purpose. Inovonics will not be liable to anyone for any consequential or incidental damages for breach of this warranty or any other warranties.

This warranty will not be modified, varied or extended. Inovonics does not authorize any person to act on its behalf to modify, vary or extend this warranty. This warranty will apply to Inovonics Products only. All other products, accessories or attachments used in conjunction with Inovonics equipment, including batteries, will be covered solely by their own warranty, if any. Inovonics will not be liable for any direct, incidental or consequential damage or loss whatsoever caused by the malfunction of Product due to products, accessories, or attachments of other manufacturers, including batteries, used in conjunction with Inovonics Products.

This warranty does not warrant the replacement of batteries that are used to power Inovonics Products.

Inovonics does not claim that the Product may not be compromised and/or circumvented.

Caution: The User should follow all installation, operation and maintenance instructions. Changes in environmental conditions, electric or electronic disruptions and tampering, may cause the Product to not perform as expected.