DCC 12 M 06/10 AIK-IBS - di-soric DCC 12 M 06/10 AIK-IBS Inductive Proximity Switch di-soric GmbH &...

1
200302 © di-soric | Subject to modifications | 22/03/20 | Page 1 (1) DCC 12 M 06/10 AIK-IBS Inductive Proximity Switch di-soric GmbH & Co. KG Steinbeisstraße 6 DE-73660 Urbach Fon + 49 (0) 71 81 / 98 79 - 0 Fax + 49 (0) 71 81 / 98 79 - 179 [email protected] www.di-soric.com TECHNICAL INFORMATION (typ.) +20°C, 24V DC Operating principle Inductive Evaluation analog Size M12 x 1 (thread) Design screw Mounting quasi-flush Characteristics extremely high operating distance Operating distance 0 … 6 mm Standardized measuring plate 18 x 18 x 1 mm Service voltage 15 ... 30 V DC No-load current < 12 mA Analog output 0 ... 10 V, 4 ... 20 mA Shock-/vibration load 10 ... 55 Hz / 1,0 mm / 30 g Switching frequency 1000 Hz Reproducibility ± 0,01 mm (TA = constant) / 0,3 mm (23°C ± 5°C) Ambient temperature, operation -25 … +70 °C Insulation voltage endurance 500 V Protection class IP 67 Casing material brass nickel plated Connection Connector, M12 M12x1 M12x1 SW 17 4 16 Ø 10.5 8 60 BN = brown BK = black BU = blue WH = white mA V 3 2 4 1 BN BK WH BU Safety instructions The Instruments are not to be used for safety applications, in particular applications in which safety of persons depends on proper operation of the instruments. These instruments shall exclusively be used by qualified personnel. Analog voltage output Analog currant output Metal plug Integrated amplifier Short-circuit protection

Transcript of DCC 12 M 06/10 AIK-IBS - di-soric DCC 12 M 06/10 AIK-IBS Inductive Proximity Switch di-soric GmbH &...

Page 1: DCC 12 M 06/10 AIK-IBS - di-soric DCC 12 M 06/10 AIK-IBS Inductive Proximity Switch di-soric GmbH & Co. KG Steinbeisstraße 6 DE-73660 Urbach Fon + 49 (0) 71 81 / 98 79 - 0 Fax + 49

200302

© di-soric | Subject to modifications | 22/03/20 | Page 1 (1)

DCC 12 M 06/10 AIK-IBS

Inductive Proximity Switch

di-soric GmbH & Co. KG Steinbeisstraße 6 DE-73660 Urbach

Fon + 49 (0) 71 81 / 98 79 - 0 Fax + 49 (0) 71 81 / 98 79 - 179 [email protected] www.di-soric.com

TECHNICAL INFORMATION (typ.) +20°C, 24V DC

Operating principle   Inductive

Evaluation   analog

Size   M12 x 1 (thread)

Design   screw

Mounting   quasi-flush

Characteristics   extremely high operating distance

Operating distance   0 … 6 mm

Standardized measuring plate   18 x 18 x 1 mm

Service voltage   15 ... 30 V DC

No-load current   < 12 mA

Analog output   0 ... 10 V, 4 ... 20 mA

Shock-/vibration load   10 ... 55 Hz / 1,0 mm / 30 g

Switching frequency   1000 Hz

Reproducibility   ± 0,01 mm (TA = constant) / 0,3 mm (23°C ± 5°C)

Ambient temperature, operation   -25 … +70 °C

Insulation voltage endurance   500 V

Protection class   IP 67

Casing material   brass nickel plated

Connection   Connector, M12

M12x1

M12x1

SW 174

16

Ø 10.5

8

60

BN = brown

BK = black

BU = blue

WH = white

mA

V

3

2

4

1BN

BK

WH

BU

Safety instructionsThe Instruments are not to be used for safety applications, in particularapplications in which safety of persons depends on proper operation of theinstruments.These instruments shall exclusively be used by qualified personnel.

Analog voltage output

Analog currant output

Metal plug

Integrated amplifier

Short-circuit protection