Model KP‐50A KP‐70A KP‐90A KP‐120A KP‐150A KP‐210APower supply V/Hz/Ph 230/50/1 230/50/1 230/50/1 230/50/1 380/50/3 380/50/3Nominal heating capacity kW 5 7 9 12 15 21Nominal cooling capacity kW 4.5 6.5 8.5 11 13.5 19COP 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2EER 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8Temperature range heating ºC 20‐55 20‐55 20‐55 20‐55 20‐55 20‐55Temperature range cooling ºC 7‐20 7‐20 7‐20 7‐20 7‐20 7‐20outdoor unitcompressor quantity 1 1 1 1 1 1compressor type twin‐rotary twin‐rotary twin‐rotary twin‐rotary scroll scrollDimensions (W x H x D) mm 840x590x290 840x700x315 880x780x360 830x1230x310 930x1270x390 930x1270x390
3. all‐in‐one design
4. Fuzzy defrosting
outdoor unit: DC inverter compressor, 3 heater for defrosting, circulation pump, water flow switch optional compoments: electrical heater backup, 3‐way‐water‐valve the connection between outdoor unit and indoor applications are anti‐freeze no water freeze on outdoor unit.
2. function: house heating. Optional function: house cooling electrical heater backup: add USD45 3‐way‐water‐valve for sanitary hot water: add USD55
DC inverter all‐in‐one
1. test condition: heating: ambient temperature ( DB/WB ): 7ºC / 6ºC, water temperature ( in/out ): 30ºC / 35ºC cooling: ambient temperature ( DB/WB ): 35ºC / 24ºC, water temperature (in/out): 12ºC / 7ºC
DC inverter compressor
DC inverter all‐in‐one ‐ installation
Model KP‐50D KP‐70D KP‐90D KP‐120D KP‐150D KP‐210DPower supply V/Hz/Ph 230/50/1 230/50/1 230/50/1 230/50/1 380/50/3 380/50/3Nominal heating capacity kW 5 7 9 12 15 21Nominal cooling capacity kW 4.5 6.5 8.5 11 13.5 19COP 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2EER 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8Temperature range heating ºC 20‐55 20‐55 20‐55 20‐55 20‐55 20‐55Temperature range cooling ºC 7‐20 7‐20 7‐20 7‐20 7‐20 7‐20Indoor unitElectrical heater backup kW 2 3 3 3 2+2+2 3+3+3Dimensions (W x H x D) mm 450x550x255 450x550x255 450x550x255 450x550x255 450x550x255 450x550x255outdoor unitcompressor quantity 1 1 1 1 1 1compressor type twin‐rotary twin‐rotary twin‐rotary twin‐rotary scroll scrollDimensions (W x H x D) mm 840x590x290 840x700x315 880x780x360 830x1230x310 930x1270x390 930x1270x390
3. split design
the connection between outdoor unit and indoor square tank is refrigerant R410a, copper connective piping. no water freeze on outdoor unit.4. Fuzzy defrosting
2. function: house heating. Optional function: house cooling
outdoor unit: DC inverter compressor, 3 heater for defrosting indoor square tank: circulation pump, water flow switch, electrical heater backup
electrical heater backup: add USD45 3‐way‐water‐valve for sanitary hot water: add USD55
DC inverter split
1. test condition: heating: ambient temperature ( DB/WB ): 7ºC / 6ºC, water temperature ( in/out ): 30ºC / 35ºC cooling: ambient temperature ( DB/WB ): 35ºC / 24ºC, water temperature (in/out): 12ºC / 7ºC
DC inverter split ‐ installation 1
DC inverter compressor
DC inverter split ‐ installation 1
DC inverter split ‐ installation 2
Model KP‐50 KP‐70 KP‐90 KP‐120 KP‐150 KP‐210Power supply V/Hz/Ph 230/50/1 230/50/1 230/50/1 230/50/1 380/50/3 380/50/3Nominal heating capacity kW 5 7 9 12 15 21Nominal cooling capacity kW 4.5 6.5 8.5 11 13.5 19COP 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2EER 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8Temperature range heating ºC 20‐55 20‐55 20‐55 20‐55 20‐55 20‐55Temperature range cooling ºC 7‐20 7‐20 7‐20 7‐20 7‐20 7‐20Indoor unitbuffer tank built‐in liter 180 180 180 180 180 180Electrical heater backup kW 2 3 3 3 2+2+2 3+3+3
Dimensions (W x H x D) mm600x1800x64
0600x1800x64
0600x1800x64
0600x1800x64
0600x1800x64
0600x1800x64
0outdoor unitcompressor quantity 1 1 1 1 1 1compressor type twin‐rotary twin‐rotary twin‐rotary twin‐rotary scroll scrollDimensions (W x H x D) mm 840x590x290 840x700x315 880x780x360 830x1230x310 930x1270x390 930x1270x390
3. split design Optional function: house cooling, solar panel
outdoor unit: evaporator, fan, 3 heater for defrosting indoor square tank: compressor, circulation pump, heat exchanger, 180 liter tank, electrical heater backup the connection between outdoor unit and indoor square tank is refrigerant R410a, copper connective piping.
4. Fuzzy defrosting no water freeze on outdoor unit. No heat loss on outdoor unit
DC inverter split combo ‐ Installation Plan
cooling: ambient temperature ( DB/WB ): 35ºC / 24ºC, water temperature (in/out): 12ºC / 7ºC
1. test condition:
2. function: sanitary hot water, house heating.
DC inverter split combo
heating: ambient temperature ( DB/WB ): 7ºC / 6ºC, water temperature ( in/out ): 30ºC / 35ºC
DC inverter split with tank ‐ Application
DC inverter split combo ‐ with 180L tank inside
refrigerant part install a module. This module can remove or install
quickly. It is good for after‐service and maintaince.
this unit can connect existing water tank.DC inverter split combo ‐ without tank inside