UNICO INVERTER DC
description
Transcript of UNICO INVERTER DC
UNICO INVERTER DC
UNICO INVERTER DC
The first INVERTER technology based heat pump without external unit on the market
The new product will be available in 4 different models
1. UNICO INVERTER DC 9 SF
2. UNICO INVERTER DC 9 HP
3. UNICO INVERTER DC 12 SF
4. UNICO INVERTER DC 12 HP
UNICO INVERTER DC
1. Outstanding quiet operation Main technology innovations
Design (King & Miranda)
2. High performance and efficiency3. High air flow and air distribution4. Installation
5. Easier maintenance6. Advanced air filters7. Low ambient control
Reduced installation time neededHigh and low installation configuration
1 – OUTSTANDING QUIET OPERATION
Unico Inverter DC
+
1 Unico Star
=
The new Unico Inverter DC’s noise level will be half the current UNICO Star
Unico Inverter DC
2 – HIGH PERFORMANCE
DC INVERTER TechnologyThe inverter control system constantly regulates the compressor motor speed, adapting it to the actual cooling or heating needs of the room
Inverter technology
=
Keeps the set temperature without oscillations
Reaches the set temperature faster
MaxComfort
Low energy consumption (reduction up to 30%)
Low noise level
2 – HIGH PERFORMANCE
2 – HIGH PERFORMANCE
2 – HIGH PERFORMANCEEER
Kw
Cooling UNICO INVERTER vs Competitors
Classe A
2 – HIGH PERFORMANCE
CO
P
Kw
Heating UNICO INVERTER vs Competitors
Classe A
Classe B
3 – HIGH COMFORT
•INCREASED AIR FLOW
520 cm/h
•IMPROVED AIR DISTRIBUTION
The air distribution has been improved increasing the size of the air outlet to 690 x 60 mm
4 - INSTALLATION
Can be installed high wall or low wall
FOR HIGH WALL INSTALLATION•Dismount plastic shell•Invert position of air outlet parts•Move LED and fan cap
TIME NEEDED20 minutes
FOR HIGH WALL INSTALLATION•Change the position of the air outlet flap, and press a key on the LED panel
TIME NEEDED1 minute
Particolare flap uscita aria
UNICO INVERTER UNICO STAR
Can be installed high wall or low wall
Installazione bassa
Installazione alta
4 – INSTALLATION
• Suggested holes are of 202 mm Ø for higher performances, but the unit can works with 162mm Ø holes as well.
Unico Inverter DC back
4 – INSTALLATION
• Second hole: behind the rear panel there is a polistyrene cylinder that reduces the size of the hole. Simply remove it.
The distance between the center of the holes remains the same as the UNICO Star. This easily allows replacing old Unico Star units with the new Unico Inverter.
• It is very easy to operate the unit with 200 mm holes. The unit is factory fitted to work with 160 mm holes, if necessary.
First hole: remove the pre-cut plastic
4 – INSTALLATION
• The minimum top/bottom and side allowances have been reduced. Unico Inverter can be installed in small niches where it was not possible to install Unico Star.
5 – Easier maintenance
The accessibility to the internal parts have been improved. It is easier to dismount and service the single components of the unit.
REAR PART FRONT PART
5 – Easier maintenance
REAR PART
LEFT PANELEncloses the: - coil zone - compressor - drain exhaust system
The back of the unit is made by two panels
RIGHT PANELEncloses the condenser fan group,. Removing some screws the whole fan group can be removed to be more easily serviced.
5 – Easier maintenance
FRONT PARTThe front part has a big frontal panel. When you remove it, you find two smaller panels.
LEFT PANELRemoving it you can access to the electric board
RIGHT PANELRemoving it you can access to - compressor - external coil probe - drain exhaust system
6 – ADVANCED AIR FILTERS
• Electrostatic filter: removes small particles and smoke, dust, pollen, pet hair, preventing allergy issues
• Active carbon filter: removes smells and deactivates harmful gases
Cleaning: The air inlet grills are very easy to dismount
Air inlet-outlet flaps openAir inlet-outlet flaps closed
7 – LOW AMBIENT CONTROL
UNICO Inverter can work in cooling mode with outside temperature up to -10C°!
This makes UNICO a perfect solution for server rooms.
TECHNICAL DATA
Unico inverter 12 SFCooling capacity (min-nom-max)
1800 – 2700 – 3100 Watt
Heating capacity /E.E.R. 2,7C.O.P. /Cooling energy efficiency class AHeating energy efficiency class /Size in mm (wxhxd) 902 x 506 x 230Weight (kg) 40Walls hole size 162-202Noise level TBD
Unico inverter 12 HP
Cooling capacity (min-nom-max)1800 - 2700 - 3100 Watt
Heating capacity1800 - 2700 - 3000 Watt
E.E.R. 2,7C.O.P. 3,2Cooling energy efficiency class AHeating energy efficiency class ASize in mm (wxhxd) 902 x 506 x 230Weight (kg) 40Walls hole size 162-202Noise level TBD
Unico inverter 9 SFCooling capacity (min-nom-max)
1400 – 2300 – 2700 Watt
Heating capacity /E.E.R. 2,7C.O.P. /Cooling energy efficiency class AHeating energy efficiency class /Size in mm (wxhxd) 902 x 506 x 230Weight (kg) 40Walls hole size 162-202Noise level TBD
Unico inverter 9 HP
Cooling capacity (min-nom-max)1400 – 2300 – 2700 Watt
Heating capacity1400 – 2400 – 2700 Watt
E.E.R. 2,7C.O.P. 3,2Cooling energy efficiency class AHeating energy efficiency class ASize in mm (wxhxd) 902 x 506 x 230Weight (kg) 40Walls hole size 162-202Noise level TBDNB: all the data shown in this presentation must be considered as preliminary
ACCESSORIES IN THE BOX
- TEMPLATE
- 2 INTERNAL FLANGES
- PAIRS OF EXTERNAL GRILLS (200 mm)
- NEW PP SHEETS TO USE FOR 200 mm HOLES (but suitable for 160mm holes as well)