DataGriffin - Overviewdatagriffin.com/wp-content/uploads/2011/10/AppNeta-… · Web viewEnterprise...

15
Overview The AppNeta PathView microAppliance is designed for remote deployment to conduct pre and post assessments and continuous performance monitoring of critical network services. Key Features Measures end to end network performance from its remote location to any target with an IP address Provides network engineers with critical insight into performance characteristics such as o Jitter o Latency o Available Bandwidth Measures the performance at each hop across unmanaged WANs What is required for utilizing the AppNeta PathView microAppliance Hardware o PathView microAppliance 1 | Page Enterprise Data Networking Informational White Paper

Transcript of DataGriffin - Overviewdatagriffin.com/wp-content/uploads/2011/10/AppNeta-… · Web viewEnterprise...

Page 1: DataGriffin - Overviewdatagriffin.com/wp-content/uploads/2011/10/AppNeta-… · Web viewEnterprise Data NetworkingInformational White PaperAppNeta PathView microAppliance Overview

OverviewThe AppNeta PathView microAppliance is designed for remote deployment to conduct pre and post assessments and continuous performance monitoring of critical network services.

Key Features Measures end to end network performance from its remote location to any target with an IP

address Provides network engineers with critical insight into performance characteristics such as

o Jittero Latencyo Available Bandwidth

Measures the performance at each hop across unmanaged WANs

What is required for utilizing the AppNeta PathView microAppliance Hardware

o PathView microAppliancehttp://www.appneta.com/products/pathview-appliances/

1 | P a g e

Enterprise Data NetworkingInformational White Paper

AppNeta PathView microAppliance

Page 2: DataGriffin - Overviewdatagriffin.com/wp-content/uploads/2011/10/AppNeta-… · Web viewEnterprise Data NetworkingInformational White PaperAppNeta PathView microAppliance Overview

Softwareo AppNeta account

http://www.appneta.com/ o PathView License for each microApplianceo AppView License for each microAppliance

PathView Cloud ConfigurationYou must configure the PathView Cloud before configuring your microAppliance.Go to https://signon.pathviewcloud.com/signon/login.jsp and sign into your account.

In the upper right corner click on Admin > Manage Organizations

Click Add Organization button

2 | P a g e

Page 3: DataGriffin - Overviewdatagriffin.com/wp-content/uploads/2011/10/AppNeta-… · Web viewEnterprise Data NetworkingInformational White PaperAppNeta PathView microAppliance Overview

Enter a NameParent should already be filled inEnter a DescriptionClick Create Organization

Your new organization is now displayed.Click Settings > Manage Sequencers

In the upper right ensure the Organization: is the organization you created.Click Download PathView Application ConfigurationSave the file to your computer.

Getting Started with the microApplianceChange the IP address on your computer to 192.168.1.5Connect the microAppliance Ethernet cable to your computerOpen a web browser and connect to 192.168.1.1Default username is rootDefault password is password

3 | P a g e

Page 4: DataGriffin - Overviewdatagriffin.com/wp-content/uploads/2011/10/AppNeta-… · Web viewEnterprise Data NetworkingInformational White PaperAppNeta PathView microAppliance Overview

Click Initial Setup Wizard

You will receive a message about the Wizard. Click Continue

I recommend leaving the password with its default setting. Press Skip

Set your Time Zone then click Save and Continue

4 | P a g e

Page 5: DataGriffin - Overviewdatagriffin.com/wp-content/uploads/2011/10/AppNeta-… · Web viewEnterprise Data NetworkingInformational White PaperAppNeta PathView microAppliance Overview

Set the Date and Time then click Save and Continue

Set the Host Name then click Save and Continue. (I will be using two microAppliance’s for a VoIP Assessment so I have named one microAppliance “MicroAppliance-Core” and the other “MicroAppliance-Voice”. You need an easily recognizable name)

In the Static configuration you can choose either DHCP or change the IP Address / Netmask / Default Gateway to an address useable on your network.Note: If you use DHCP you will still be able to manage the microAppliance via PathView without knowing the IP address.

Choose Yes

5 | P a g e

Page 6: DataGriffin - Overviewdatagriffin.com/wp-content/uploads/2011/10/AppNeta-… · Web viewEnterprise Data NetworkingInformational White PaperAppNeta PathView microAppliance Overview

Click Choose FileChoose the file you saved from PathView and choose OpenClick Save to load the configuration file from PathView.

Choose Restart Now

Connect the microAppliance to your network.Change the IP Address on your computer back to its original state.

Using the PathView CloudReturn to the PathView CloudIn the upper right click Settings > Manage LicensesEnsure your Organization: is the new Organization you created

Available Licences will appear under Purchased LicensemicroAppliance will be listed under Unlicensed Sequencers

6 | P a g e

Page 7: DataGriffin - Overviewdatagriffin.com/wp-content/uploads/2011/10/AppNeta-… · Web viewEnterprise Data NetworkingInformational White PaperAppNeta PathView microAppliance Overview

In the Purchased License the first line “AppView Voice – m20” is listed in the Organization “VoIP Assessment”. Under Sequencer use the drop down to choose your first microAppliance.In the Purchased License the second line “PathView 220 –m20” is listed in the Organization “VoIP Assessment”. Under Sequencer use the drop down to choose your first microAppliance.If you have two microAppliances do the same thing and assign one AppView license and one PathView license. The settings are automatically saved.

In the upper right choose Settings > Manage Sequencers

Your microAppliances are listed here.Notice the detail window on the right for the microAppliance that is highlighted.Click on Enable Remote Access to Web Admin and wait for this to finish. This will allow remote management of device. Once this finishes you will notice the Enable Remote Access to Web Admin button is replaced by the link Launch PathView Appliance Web Admin.You can now manage the microAppliance without knowing the IP address.Do this for all of your microAppliances listed.

7 | P a g e

Page 8: DataGriffin - Overviewdatagriffin.com/wp-content/uploads/2011/10/AppNeta-… · Web viewEnterprise Data NetworkingInformational White PaperAppNeta PathView microAppliance Overview

You have now completed configuring the microAppliances and assigned licenses to them.

Adding Paths to PathView CloudTo begin network analysis with the microAppliances you must create a path.In the upper left click PathView

Click Add Paths button

8 | P a g e

Page 9: DataGriffin - Overviewdatagriffin.com/wp-content/uploads/2011/10/AppNeta-… · Web viewEnterprise Data NetworkingInformational White PaperAppNeta PathView microAppliance Overview

There are 4 options to setting up Paths. The simplest way is Option 3. In the Monitor From column choose the microAppliance you want to set at your core. In the Target IP Address / Host Name enter the IP address of the other microAppliance you are using. This can be found by clicking on Settings > Manage Sequencers, highlighting the microAppliance and getting the IP address from the details window.In the example below I will be performing a VoIP Assessment so you will notice I have chosen to Monitor From the microAppliance-Core, the Target IP Address is the IP Address of the microAppliance-Voice, Network Type is LAN, Target Type is Voice Server and the Group is Default.You can also use any Target IP Address that is pingable but more detailed test results will be available by using the Target IP Address of another microAppliance.

9 | P a g e

Page 10: DataGriffin - Overviewdatagriffin.com/wp-content/uploads/2011/10/AppNeta-… · Web viewEnterprise Data NetworkingInformational White PaperAppNeta PathView microAppliance Overview

Click Add Paths button

Click on the Path Name

10 | P a g e

Page 11: DataGriffin - Overviewdatagriffin.com/wp-content/uploads/2011/10/AppNeta-… · Web viewEnterprise Data NetworkingInformational White PaperAppNeta PathView microAppliance Overview

If the connection between the microAppliance and the IP address you entered is setting up you will see the message “Diagnosis service quality evaluation in progress…”Otherwise you will see the below screen.

Create an Assessment by clicking on PathView >Assess > Assessments.Click on New Voice Assessment or New Data Assessment depending on the test you will be performing.

Enter an Assessment Name and Comment.Press the Add from Monitored Paths button.

11 | P a g e

Page 12: DataGriffin - Overviewdatagriffin.com/wp-content/uploads/2011/10/AppNeta-… · Web viewEnterprise Data NetworkingInformational White PaperAppNeta PathView microAppliance Overview

Ensure the Existing Paths are checked and then press Add Paths button.

In the Assessment Settings section leave the Concurrent Calls at 5.Remove any call analysis except the target type you created. In the Voice Codec section change the codec to the type you are or will be using.In the Quality of Service section check the Perform QoS Testing then choose the QoS Format, TOS and Precedence.Press the Start Assessment button to begin testing.

You can view the progress by clicking on the Name of the Assessment. As the test is running the Generate Report button will be greyed out.

Once the test has completed press the Generate Report button to view your results.

12 | P a g e

Page 13: DataGriffin - Overviewdatagriffin.com/wp-content/uploads/2011/10/AppNeta-… · Web viewEnterprise Data NetworkingInformational White PaperAppNeta PathView microAppliance Overview

Enter the Filename.Check the Include individual test resultsPrepared For: Client NamePrepared By: Your NameTitle Page Logo: OptionalTitle Page Logo URL: http://www.IntegrationPartners.comPage Logo: OptionalPage Logo URL: http://www.IntegrationPartners.comPress the Generate button.

Choose a location to save the file then press Save button.

13 | P a g e

Page 14: DataGriffin - Overviewdatagriffin.com/wp-content/uploads/2011/10/AppNeta-… · Web viewEnterprise Data NetworkingInformational White PaperAppNeta PathView microAppliance Overview

When you open the .zip file you will see your report and a Test_Results folder.The folder contains the PathView report for each MicroAppliance in detail.

14 | P a g e