9-165 Data Link Circuit, SAE J1939
Table of Contents
General InformationResistance CheckCheck for Short Circuit to GroundCheck for Short Circuit from Pin to Pin
General Information TOC
The OEM J1939 datalink circuit is located in the OEM wiring harness.
The purpose of this datalink is to allow communication with vehicle control-operated systems such as transmission controllers, traction control system, etc.
The traditional OEM J1939 datalink circuit is described as a shielded twisted pair and includes the wires connected to the J1939 datalink positive (+) pin, the J1939 datalink negative (-) pin, and the J1939 (shield) pin in the OEM harness.
On newer vehicles and equipment, OEM's can utilize an OEM J1939 datalink circuit that is described as an unshielded twisted pair (UTP). The unshielded twisted pair (UTP) J1939 datalink does not include the J1939 (shield) pin and only includes the J1939 datalink positive (+) pin and the J1939 datalink negative (-) pin in the
SMALL | MEDIUM | LARGE
Next
OEM harness.
With the keyswitch in the ON position, public datalink messages
The Society of Automotive Engineers (SAE) J1939 has strict guidelines that must be followed for successful communication. Understanding some fundamentals about SAE J1939 will help make sure these guidelines are followed.
The main component of an SAE J1939 system is a backbone harness. The harness can be up to 40 meters [131 feet] in length. The backbone harness is terminated at each end with a 120 ohm resistor.
A maximum of thirty different devices can be attached to the SAE J1939 backbone at once. Each device, such as the datalink adapter, is connected to the backbone through a stub, which can be up to 1 meter [3.3 ft] in length. The stub connector is a 3-pin plug.
SMALL | MEDIUM | LARGE
Previous Next
The terminating resistor caps (1) must be in place on the OEM backbone harness plugs (2) to maintain proper communication. Each resistor is 120 ohms and can be located in a removable cap.
SMALL | MEDIUM | LARGE
Previous Next
SMALL | MEDIUM | LARGE
Previous Next
Pin Signal
A Ground
B Unswitched Battery
C J1939 datalink (+)
D J1939 datalink (-)
E J1939 datalink (shield) (if available)
F J1708 datalink (+)
G J1708 datalink (-)
H Open
J Open
SMALL | MEDIUM | LARGE
Previous Next
Resistance Check TOC
WARNING
Batteries can emit explosive gases. To reduce the possibility of personal injury, always ventilate the compartment before servicing the batteries. To reduce the possibility of arcing, remove the negative (-) battery cable first and attach the negative (-) battery cable last.
CAUTION
Proper leads and/or a Cummins® approved circuit testing tool must be used when working with electrical connectors to prevent pin expansion and damage to the connector.
SMALL | MEDIUM | LARGE
Previous Next
Check for Short Circuit from Pin to Pin TOC
CAUTION
Proper leads and/or a Cummins® approved circuit testing tool must be used when working with electrical connectors to prevent pin expansion and damage to the connector.
Disconnect the OEM harness connector from the ECU.
Insert a test lead into the SAE J1939 datalink positive (+) pin of the OEM harness connector and connect it to the multimeter probe. Insert the other test lead into another pin in the connector of the OEM harness and connect it to the other multimeter probe.
Measure the resistance from the SAE J1939 datalink positive (+) pin to the first pin in the connector. The multimeter must show an open circuit (100k ohms or more).
If the circuit is not open, repair or replace the OEM harness. Refer to the OEM troubleshooting and repair manual.
SMALL | MEDIUM | LARGE
Previous Next
Measure the resistance from the SAE J1939 datalink positive (+) pin of the OEM harness connector to all other pins in the connector, one at a time. The multimeter mustshow an open circuit (100k ohms or more) at all pins, except the J1939 datalink negative (-).
If the circuit is not open, repair or replace the OEM harness. Refer to the OEM troubleshooting and repair manual.
SMALL | MEDIUM | LARGE
Previous Next
Remove the test lead from the J1939 datalink positive (+) pin and insert it into the J1939 datalink (shield) pin of the OEM harness connector, if the shield pin is available
NOTE: If the J1939 datalink circuit is an unshielded twisted pair (UTP), the (shield) pin will not be provided. If the shield pin is not provided, the datalink negative (-) pin must still be checked for a short circuit to the other pins.
Insert the other test lead into another pin in the connector. Measure the resistance.
The multimeter must show an open circuit (100k ohms or more).
If the circuit is not open, repair or replace the OEM harness. Refer to the OEM troubleshooting and
SMALL | MEDIUM | LARGE
Previous Next
repair manual.
SMALL | MEDIUM | LARGE
Previous Next
SMALL | MEDIUM | LARGE
Previous Next
SMALL | MEDIUM | LARGE
Previous
SMALL | MEDIUM | LARGE
9-Pin Data link Cable, Part Number 3165159
SMALL | MEDIUM | LARGE
9-Pin In-Cab Data link Connector
A. Ground B. Battery (+) C. J1939 data link (+) D. J1939 data link (-) E. J1939 data link shield F. J1708 data link (+) G. J1708 data link (-) H. Open
J. Open
Mida la resistencia de las clavijas de A, B, C, D, E, F y G en el conector de 9 pines a la ubicación correspondiente en el conector de 25 pines, como se muestra. El multímetro debe mostrar un circuito cerrado (10 ohmios o menos). Si un circuito cerrado IsNot, sustituya el cable de enlace de datos
CAUTION
To avoid the possibility of damage to connector pins, use male test lead, Part Number 3824811, on the 6-pin Deutsch™ connector. Use male test lead, Part Number 3822758, on the 25-pin connector.
SMALL | MEDIUM | LARGE
6-Pin Data link Cable, Part Number 3165160
SMALL | MEDIUM | LARGE
6-Pin In-Cab Data link Connector
A. J1708 data link (+)B. J1708 data link (-)C. Battery (+)D. OpenE. GroundF. Open.
Mida la resistencia de las clavijas de A, B, C, y E en el conector de 6 pines a la ubicación correspondiente en el conector de 25 pines, como se muestra. El multímetro debe mostrar un circuito cerrado (10 ohmios o menos). Si se notclosed un circuito, cambiar el cable de enlace de datos
CAUTION
To avoid the possibility of damage to the connector pins, use male test lead, Part Number 3822758, on the 25-pin connector. Use female test lead, Part Number 3823994, on the 3-pin connector. Use male test lead, Part Number 3822995, on the 2-pin power connector.
SMALL | MEDIUM | LARGE
3-Pin Data link Cable, Part Number 3165141
Mida la resistencia de las clavijas de A, B y C en el conector de 3-pin a la ubicación correspondiente en el conector de 25 pines, como se muestra. Mida la resistencia de los pines D y E en el conector de alimentación de 2 pines a la ubicación correspondiente en el conector de 5 pines como se muestra. El multímetro debe mostrar un circuito cerrado (10 ohmios o menos). Si un circuito no está cerrado, sustituya el cable de enlace de datos.
CAUTION
To avoid the possibility of damage to connector pins, use two male test leads, Part Number 3823993, on each 3-pin connector.
SMALL | MEDIUM | LARGE
Mini Backbone Cable, Part Number 3163096
Medir la resistencia de clavija A en un extremo del cable principal a la clavija A en el extremo opuesto del cable principal. Repetir para los pines B y C. El multímetro debe mostrar un circuito cerrado (10 ohmios o menos). Si un circuito no está cerrado, sustituya el cable principal. Medir la resistencia entre los pines A y B en cada extremo del cable para medir la resistencia de terminación. El valor de la resistencia de terminación debe medir entre 50 a 70 ohms.
CAUTION
To avoid the possibility of damage to connector pins, use two female test leads, Part Number 3823994, on each 3-pin connector.
SMALL | MEDIUM | LARGE
Gender Changer Cable, Part Number 3163597
Mida la resistencia de clavija A en un extremo del cable de cambiador de género a la clavija A en el extremo opuesto del cable de cambiador de género. Repetir para los pines B y C. El multímetro debe mostrar un circuito cerrado (10 ohmios o menos). Si un circuito no está cerrado, sustituya el cable del cambiador de género.