Danfoss Air UnitsTechnical data

DANFOSS HEATING

MAKING MODERN LIVING POSSIBLE

530

Ø125Supply

415

(430

incl

. wal

l bra

cket

)

Top view

Ø125Exhaust

Ø125Outdoor

air

Ø125Discharge

1000

(104

2 in

cl. a

ir s

pig

ots)

Front view

Ø125(below)

Unit weight: 31 kg

Danfoss Air Unit: w1 (small houses and appartments)

Short description

Physical properties

Electrical data

Misc.

The Danfoss Air Unit w1 is a wall-mounted unit, designed for installation in either a utility room or boiler room. The compact dimensions of the unit allows it to be mounted inside a standard cupboard. The unit has an extra supply air connection on the underside for connection to a floor-based supply air system if necessary. This unit does not have the bypass damper. The unit is supplied with a communication module, a wireless controller (the Air Dial) and comes with all necessary cables. The unit is highly insulated to prevent heat loss, and to aid sound suppres-sion. Supplied w. G4/G4 filters (F7 as an option for supply air). Construced from steel casing with expanded polystyrene core.

Width 530 mm Depth 430 mm Height 1042 mmDiameter, ducts Ø125Weight 31 kgInsulation level U-value < 0.9Finish, powder coat RAL 9010

Power, AC 230 VAC + 10%Max. current <1 A Typical consumption 40 W@140 m3/h and 70 Pa ext. pressure Frequency 50 Hz +2 %Motor type EC-motorsSensors 4 temp. + RH%Air dial batteries 4 x AAA

Undergoing Passive House certification.All performance testing acc. to EN 308.Complies with EN 13141-7.Fire class as DIN 4102-B2 .

Drain connection Ø19 plastic connection piece for ¾” hose, placed underneath the unit.

2 VDEWA202

Unit weight: 45 kg

590

Top view

Front view

Ø160Discharge

Ø160Outdoor

air

Ø160 Supply

Ø160Exhaust

565

(580

incl

. wal

l bra

cket

)10

50 (1

090

incl

. air

sp

igot

s)

Danfoss Air Unit: w2 (medium-sized and large houses)

Short description

Physical properties

Electrical data

Drain connection

The Danfoss Air Unit w2 is a wall-mounted unit, intended for installation in either a utility room or boiler room. The unit can be installed in a space equivalent to a standard 60x60cm module. This unit has an automatic bypass damper fitted as standard. The unit is supplied with a commu-nication module, a wireless controller (the Air Dial) and comes with all necessary cables. The unit is highly insulated to prevent heat loss, and to aid sound suppression. Supplied w. G4/G4 filters (F7 as an option for supply air). Construced from steel casing with expanded polystyrene core.

Width 590 mm Depth 580 mm Height 1050 mmDiameter, ducts Ø160Weight 45 kgInsulation level U-value < 0.9Finish, powder coat RAL 9010

Power, AC 230 VAC + 10%Max. current <1 A Typical consumption 53 W@220 m3/h 70 Pa ext. pressure Frequency 50 Hz +2 %Motor type EC-motorsSensors 4 temp. + RH%Air dial batteries 4 x AAA

Ø19 plastic connection piece for ¾” hose, placed underneath the unit.

Misc. Undergoing Passive House certification.All performance testing acc. to EN 308.Complies with EN 13141-7.Fire class as DIN 4102-B2.

3VDEWA202

1180

600

58032515

177

450

Ø160

Exhaust air

Discharge airSupply air

Outdoor air

Discharge air

Outdoor air

Unit weight: 52 kg

Front viewRight view

Danfoss Air Unit: a2 (medium-sized and large houses)

Short description

Electrical data

Physical properties

Misc.

The Danfoss Air Unit a2 is an attic mounted unit, intended for installation in either an attic room or boiler room. This unit has an automatic bypass damper fitted as standard. The unit is supplied with a communication module, a wireless con-troller (the Air dial) and comes with all necessary

cables. The unit is highly insulated to prevent heat loss, and to aid sound suppression. Supplied w. G4/G4 filters (F7 as an option for supply air). Construced from steel casing with expanded polystyrene core.

Power, AC 230 VAC + 10%Max. current <1 A Typical consumption 52 W@220 m3/h and 70 Pa ext. pressure Frequency 50 Hz +2 %Motor type EC-motorsSensors 4 temp. + RH%Air dial batteries 4 x AAA

Width 580 mm Height 600 mmLength 1180 mmDiameter, ducts Ø160Weight 52 kgInsulation level U-value < 0.7Finish, AlZ-n coated 3 µm

Undergoing Passive House certification.All performance testing acc. to EN 308.Complies with EN 13141-7.Fire class as DIN 4102-B2.

Drain connection Ø19 plastic connection piece for ¾” hose, placed below on the back of the unit.

4 VDEWA202

The Danfoss Air Unit a2 is an attic mounted unit, intended for installation in either an attic room or boiler room. This unit has an automatic bypass damper fitted as standard. The unit is supplied with a communication module, a wireless con-troller (the Air Dial) and comes with all necessary

cables. The unit is highly insulated to prevent heat loss, and to aid sound suppression. Supplied w. G4/G4 filters (F7 as an option for supply air). Construced from steel casing with expanded polystyrene core.

Danfoss Air Unit: a3 (very large houses, small commercial areas)

Short description

Electrical data

Physical properties

Misc.

118015 540

780

160

280

330

Exhaust air

Supply air

Outdoor air

Discharge air

Unit weight: 66 kg

600

Discharge air

Outdoor air

Ø250

Front viewRight view

Power, AC 230 VAC + 10%Max. current <1 A Typical consumption 79 W@350 m3/h and 70 Pa ext. pressure Frequency 50 Hz +2 %Motor type EC-motorsSensors 4 temp. + RH%Air dial batteries 4 x AAA

Width 780 mm Height 600 mmLength 1180 mmDiameter, ducts Ø250Weight 66 kgInsulation level U-value < 0.7Finish, AlZ-n coated 3 µm

Undergoing Passive House certification.All performance testing acc. to EN 308.Complies with EN 13141-7.Fire class as DIN 4102-B2.

Drain connection Ø19 plastic connection piece for ¾” hose, placed below on the back of the unit.

5VDEWA202

The control solution offered is wireless (Z-wave) and incorporates the Danfoss heating architec-ture. The end user navigates with the dial, the centre of the the dial acts as a push button (i.e. ”Enter”). The Air Dial has a full 64 x 100 pixel resolution graphic display, and will allow up to 7 lines of 12 characters each (varies). The battery powered Air Dial (4 x AAA batteries are used) has an expected minimum life time under normal conditions of 2 years.

The Air Dial communicates with the communi-cation module. The communication module is plugged into the ventilation unit, and acts as and external wireless receiver and transmitter. The communication module also allows the con-

nection of various accessories, via the integrated mini USB and ethernet connection.

All devices and accessories sold by Danfoss Ventilation are based on an easy to use ”plug’n play” concept. The ventilation unit itself is supplied with all the necessary sensors fitted ex works. All our units are fitted with four tempe-rature sensors (outdoor, supply, exhaust and discharge) and the Air Dial also has a room tempera-ture sensor onboard.

We are one of the first suppliers to offer a demand-based ventilation concept, as standard on all units.

Danfoss Air Controls

Short description

6 VDEWA202

Air DialCommunication module

Danfoss Air

5060708090

100110120130140150160170180190200

25 50 75 100 125 150 175 200 225 250 275 300

P ext. [Pa]

[m3/h]

100%

67%45%

82%

SFP 1200

SFP 1000

SFP 800

Flow properties / Strömungsverhältnisse / Luftdata

60 100 140 180 220 260 300[m3/h]

Dry efficiency / WRG trocken / Tør virkningsgrad

89

91

87

85

83

81

Eta T [%] acc. EN 308 / Laut EN 308 / Jf. EN 308

Flow Pext. SFP P1 tot.[m3/h] [Pa] [J/m3] [W]160 50 684 30220 70 824 50220 100 995 61260 70 947 68260 100 1105 80300 90 1140 95

Typical operation / Typische Arbeitspunkte

Typiske driftspunkter

By condensation up to 95%

Bei Kondensation bis zu 95%

Ved kondensering op til 95%

63

31

32

(1) Lw(A)

(2) Lw(A)

(3) Lp(A) Unit / Gerät / Anlæg til rum: 51

125

41

43

250

47

50

500

46

47

1000

41

42

2000

39

40

4000

29

29

Hz

dB(A)

dB(A)

dB(A)

63

32

28

(4) Lw(A)

(5) Lw(A)

(6) Lp(A) Unit / Gerät / Anlæg til rum: 54

125

44

44

250

49

51

500

49

48

1000

45

45

2000

43

42

4000

33

32

Hz

dB(A)

dB(A)

dB(A)

(1) Exhaust / Abluft / Udsugning @ 220 m3/h(2) Supply / Zuluft / Indblæsning @ 220 m3/h(3) Hard room / Harter raum / hårdt rum @ 220 m3/h

(4) Exhaust / Abluft / Udsugning @ 260 m3/h(5) Supply / Zuluft / Indblæsning @ 260 m3/h(6) Hard room / Harter raum / hårdt rum @ 260 m3/h

Danfoss Air a2

5060708090

100110120130140150160170180190200

50 100 150 200 250 300 350 400 450 500 550 600

P ext. [Pa]

[m3/h]

SFP 1200

Flow properties / Strömungsverhältnisse / Luftdata

200 250 300 350 400 450 500[m3/h]

Dry efficiency / WRG trocken / Tør virkningsgrad

89

91

87

85

83

81

Eta T [%] acc. EN 308 / Laut EN 308 / Jf. EN 308

Flow Pext. SFP P1 tot.[m3/h] [Pa] [J/m3] [W]200 70 900 50350 70 802 78450 70 832 104450 100 1080 135

Typical operation / Typische Arbeitspunkte

Typiske driftspunkter

By condensation up to 95%

Bei Kondensation bis zu 95%

Ved kondensering op til 95%

63

35

35

(1) Lw(A)

(2) Lw(A)

(3) Lp(A) Unit / Gerät / Anlæg til rum: 57

125

44

45

250

51

56

500

48

49

1000

48

47

2000

44

44

4000

31

31

Hz

dB(A)

dB(A)

dB(A)

63

39

39

(4) Lw(A)

(5) Lw(A)

(6) Lp(A) Unit / Gerät / Anlæg til rum: 61

125

47

48

250

61

62

500

55

55

1000

53

52

2000

48

50

4000

37

37

Hz

dB(A)

dB(A)

dB(A)

(1) Exhaust / Abluft / Udsugning @ 350 m3/h(2) Supply / Zuluft / Indblæsning @ 350 m3/h(3) Hard room / Harter raum / hårdt rum @ 350 m3/h

(4) Exhaust / Abluft / Udsugning @ 450 m3/h(5) Supply / Zuluft / Indblæsning @ 450 m3/h(6) Hard room / Harter raum / hårdt rum @ 450 m3/h

Danfoss Air a3

100%

SFP 1000 55%

79%

SFP 800

7VDEWA202

Danfoss A/SUlvehavevej 617100 Vejle

Tel. +45 74 88 85 00Fax +45 74 88 86 03www.danfoss.comwww.air-danfoss.com

Danfoss Air

5060708090

100110120130140150160170180190200

25 50 75 100 125 150 175 200 225 250 275 300

P ext. [Pa]

[m3/h]

SFP 1200

Flow properties / Strömungsverhältnisse / Luftdata

60 100 140 180 220 260 300[m3/h]

Dry efficiency / WRG trocken / Tør virkningsgrad

89

91

87

85

83

81

Eta T [%] acc. EN 308 / Laut EN 308 / Jf. EN 308

Flow Pext. SFP P1 tot.[m3/h] [Pa] [J/m3] [W]100 35 720 20100 55 792 22140 60 951 37140 70 1029 40180 70 1080 54180 100 1300 65

Typical operation / Typische Arbeitspunkte

Typiske driftspunkter

63

22

20

(1) Lw(A)

(2) Lw(A)

(3) Lp(A) Unit / Gerät / Anlæg til rum: 50

125

37

36

250

46

44

500

46

46

1000

43

43

2000

37

37

4000

25

26

Hz

dB(A)

dB(A)

dB(A)

63

34

31

(4) Lw(A)

(5) Lw(A)

(6) Lp(A) Unit / Gerät / Anlæg til rum: 55

125

43

42

250

50

47

500

51

50

1000

48

48

2000

42

42

4000

31

31

Hz

dB(A)

dB(A)

dB(A)

(1) Exhaust / Abluft / Udsugning @ 140 m3/h(2) Supply / Zuluft / Indblæsning @ 140 m3/h(3) Hard room / Harter raum / hårdt rum @ 140 m3/h

(4) Exhaust / Abluft / Udsugning @ 180 m3/h(5) Supply / Zuluft / Indblæsning @ 180 m3/h(6) Hard room / Harter raum / hårdt rum @ 180 m3/h

Danfoss Air w1

By condensation up to 95%

Bei Kondensation bis zu 95%

Ved kondensering op til 95%

100%

84%35%

SFP 1000

66%

5060708090

100110120130140150160170180190200

25 50 75 100 125 150 175 200 225 250 275 300

P ext. [Pa]

[m3/h]

100%

67%45%

82%

SFP 1200

SFP 1000

SFP 800

Flow properties / Strömungsverhältnisse / Luftdata

60 100 140 180 220 260 300[m3/h]

Dry efficiency / WRG trocken / Tør virkningsgrad

88

89

87

86

85

84

Eta T [%] acc. EN 308 / Laut EN 308 / Jf. EN 308

Flow Pext. SFP P1 tot.[m3/h] [Pa] [J/m3] [W]160 50 720 32220 70 867 53220 100 1047 64260 70 997 72260 100 1163 84300 90 1200 100

Typical operation / Typische Arbeitspunkte

Typiske driftspunkter

By condensation up to 95%

Bei Kondensation bis zu 95%

Ved kondensering op til 95%

63

30

25

(1) Lw(A)

(2) Lw(A)

(3) Lp(A) Unit / Gerät / Anlæg til rum: 60

125

41

42

250

47

52

500

48

50

1000

46

48

2000

42

44

4000

32

34

Hz

dB(A)

dB(A)

dB(A)

63

33

28

(4) Lw(A)

(5) Lw(A)

(6) Lp(A) Unit / Gerät / Anlæg til rum: 63

125

46

46

250

57

55

500

57

54

1000

55

52

2000

51

48

4000

43

40

Hz

dB(A)

dB(A)

dB(A)

(1) Exhaust / Abluft / Udsugning @ 220 m3/h(2) Supply / Zuluft / Indblæsning @ 220 m3/h(3) Hard room / Harter raum / hårdt rum @ 220 m3/h

(4) Exhaust / Abluft / Udsugning @ 260 m3/h(5) Supply / Zuluft / Indblæsning @ 260 m3/h(6) Hard room / Harter raum / hårdt rum @ 260 m3/h

Danfoss Air w2

www.danfoss.comVDEWA102 A1.02