Danfoss Air Unit: w1 (small houses and appartments)
Short description
Physical properties
Electrical data
Misc.
The Danfoss Air Unit w1 is a wall-mounted unit, designed for installation in either a utility room or boiler room. The compact dimensions of the unit allows it to be mounted inside a standard cupboard. The unit has an extra supply air connection on the underside for connection to a floor-based supply air system if necessary. This unit does not have the bypass damper. The unit is supplied with a communication module, a wireless controller (the Air Dial) and comes with all necessary cables. The unit is highly insulated to prevent heat loss, and to aid sound suppres-sion. Supplied w. G4/G4 filters (F7 as an option for supply air). Construced from steel casing with expanded polystyrene core.
Width 530 mm Depth 430 mm Height 1042 mmDiameter, ducts Ø125Weight 31 kgInsulation level U-value < 0.9Finish, powder coat RAL 9010
Power, AC 230 VAC + 10%Max. current <1 A Typical consumption 40 W@140 m3/h and 70 Pa ext. pressure Frequency 50 Hz +2 %Motor type EC-motorsSensors 4 temp. + RH%Air dial batteries 4 x AAA
Undergoing Passive House certification.All performance testing acc. to EN 308.Complies with EN 13141-7.Fire class as DIN 4102-B2 .
Drain connection Ø19 plastic connection piece for ¾” hose, placed underneath the unit.
2 VDEWA202
Unit weight: 45 kg
590
Top view
Front view
Ø160Discharge
Ø160Outdoor
air
Ø160 Supply
Ø160Exhaust
565
(580
incl
. wal
l bra
cket
)10
50 (1
090
incl
. air
sp
igot
s)
Danfoss Air Unit: w2 (medium-sized and large houses)
Short description
Physical properties
Electrical data
Drain connection
The Danfoss Air Unit w2 is a wall-mounted unit, intended for installation in either a utility room or boiler room. The unit can be installed in a space equivalent to a standard 60x60cm module. This unit has an automatic bypass damper fitted as standard. The unit is supplied with a commu-nication module, a wireless controller (the Air Dial) and comes with all necessary cables. The unit is highly insulated to prevent heat loss, and to aid sound suppression. Supplied w. G4/G4 filters (F7 as an option for supply air). Construced from steel casing with expanded polystyrene core.
Width 590 mm Depth 580 mm Height 1050 mmDiameter, ducts Ø160Weight 45 kgInsulation level U-value < 0.9Finish, powder coat RAL 9010
Power, AC 230 VAC + 10%Max. current <1 A Typical consumption 53 W@220 m3/h 70 Pa ext. pressure Frequency 50 Hz +2 %Motor type EC-motorsSensors 4 temp. + RH%Air dial batteries 4 x AAA
Ø19 plastic connection piece for ¾” hose, placed underneath the unit.
Misc. Undergoing Passive House certification.All performance testing acc. to EN 308.Complies with EN 13141-7.Fire class as DIN 4102-B2.
3VDEWA202
1180
600
58032515
177
450
Ø160
Exhaust air
Discharge airSupply air
Outdoor air
Discharge air
Outdoor air
Unit weight: 52 kg
Front viewRight view
Danfoss Air Unit: a2 (medium-sized and large houses)
Short description
Electrical data
Physical properties
Misc.
The Danfoss Air Unit a2 is an attic mounted unit, intended for installation in either an attic room or boiler room. This unit has an automatic bypass damper fitted as standard. The unit is supplied with a communication module, a wireless con-troller (the Air dial) and comes with all necessary
cables. The unit is highly insulated to prevent heat loss, and to aid sound suppression. Supplied w. G4/G4 filters (F7 as an option for supply air). Construced from steel casing with expanded polystyrene core.
Power, AC 230 VAC + 10%Max. current <1 A Typical consumption 52 W@220 m3/h and 70 Pa ext. pressure Frequency 50 Hz +2 %Motor type EC-motorsSensors 4 temp. + RH%Air dial batteries 4 x AAA
Width 580 mm Height 600 mmLength 1180 mmDiameter, ducts Ø160Weight 52 kgInsulation level U-value < 0.7Finish, AlZ-n coated 3 µm
Undergoing Passive House certification.All performance testing acc. to EN 308.Complies with EN 13141-7.Fire class as DIN 4102-B2.
Drain connection Ø19 plastic connection piece for ¾” hose, placed below on the back of the unit.
4 VDEWA202
The Danfoss Air Unit a2 is an attic mounted unit, intended for installation in either an attic room or boiler room. This unit has an automatic bypass damper fitted as standard. The unit is supplied with a communication module, a wireless con-troller (the Air Dial) and comes with all necessary
cables. The unit is highly insulated to prevent heat loss, and to aid sound suppression. Supplied w. G4/G4 filters (F7 as an option for supply air). Construced from steel casing with expanded polystyrene core.
Danfoss Air Unit: a3 (very large houses, small commercial areas)
Short description
Electrical data
Physical properties
Misc.
118015 540
780
160
280
330
Exhaust air
Supply air
Outdoor air
Discharge air
Unit weight: 66 kg
600
Discharge air
Outdoor air
Ø250
Front viewRight view
Power, AC 230 VAC + 10%Max. current <1 A Typical consumption 79 W@350 m3/h and 70 Pa ext. pressure Frequency 50 Hz +2 %Motor type EC-motorsSensors 4 temp. + RH%Air dial batteries 4 x AAA
Width 780 mm Height 600 mmLength 1180 mmDiameter, ducts Ø250Weight 66 kgInsulation level U-value < 0.7Finish, AlZ-n coated 3 µm
Undergoing Passive House certification.All performance testing acc. to EN 308.Complies with EN 13141-7.Fire class as DIN 4102-B2.
Drain connection Ø19 plastic connection piece for ¾” hose, placed below on the back of the unit.
5VDEWA202
The control solution offered is wireless (Z-wave) and incorporates the Danfoss heating architec-ture. The end user navigates with the dial, the centre of the the dial acts as a push button (i.e. ”Enter”). The Air Dial has a full 64 x 100 pixel resolution graphic display, and will allow up to 7 lines of 12 characters each (varies). The battery powered Air Dial (4 x AAA batteries are used) has an expected minimum life time under normal conditions of 2 years.
The Air Dial communicates with the communi-cation module. The communication module is plugged into the ventilation unit, and acts as and external wireless receiver and transmitter. The communication module also allows the con-
nection of various accessories, via the integrated mini USB and ethernet connection.
All devices and accessories sold by Danfoss Ventilation are based on an easy to use ”plug’n play” concept. The ventilation unit itself is supplied with all the necessary sensors fitted ex works. All our units are fitted with four tempe-rature sensors (outdoor, supply, exhaust and discharge) and the Air Dial also has a room tempera-ture sensor onboard.
We are one of the first suppliers to offer a demand-based ventilation concept, as standard on all units.
Danfoss Air Controls
Short description
6 VDEWA202
Air DialCommunication module
Danfoss Air
5060708090
100110120130140150160170180190200
25 50 75 100 125 150 175 200 225 250 275 300
P ext. [Pa]
[m3/h]
100%
67%45%
82%
SFP 1200
SFP 1000
SFP 800
Flow properties / Strömungsverhältnisse / Luftdata
60 100 140 180 220 260 300[m3/h]
Dry efficiency / WRG trocken / Tør virkningsgrad
89
91
87
85
83
81
Eta T [%] acc. EN 308 / Laut EN 308 / Jf. EN 308
Flow Pext. SFP P1 tot.[m3/h] [Pa] [J/m3] [W]160 50 684 30220 70 824 50220 100 995 61260 70 947 68260 100 1105 80300 90 1140 95
Typical operation / Typische Arbeitspunkte
Typiske driftspunkter
By condensation up to 95%
Bei Kondensation bis zu 95%
Ved kondensering op til 95%
63
31
32
(1) Lw(A)
(2) Lw(A)
(3) Lp(A) Unit / Gerät / Anlæg til rum: 51
125
41
43
250
47
50
500
46
47
1000
41
42
2000
39
40
4000
29
29
Hz
dB(A)
dB(A)
dB(A)
63
32
28
(4) Lw(A)
(5) Lw(A)
(6) Lp(A) Unit / Gerät / Anlæg til rum: 54
125
44
44
250
49
51
500
49
48
1000
45
45
2000
43
42
4000
33
32
Hz
dB(A)
dB(A)
dB(A)
(1) Exhaust / Abluft / Udsugning @ 220 m3/h(2) Supply / Zuluft / Indblæsning @ 220 m3/h(3) Hard room / Harter raum / hårdt rum @ 220 m3/h
(4) Exhaust / Abluft / Udsugning @ 260 m3/h(5) Supply / Zuluft / Indblæsning @ 260 m3/h(6) Hard room / Harter raum / hårdt rum @ 260 m3/h
Danfoss Air a2
5060708090
100110120130140150160170180190200
50 100 150 200 250 300 350 400 450 500 550 600
P ext. [Pa]
[m3/h]
SFP 1200
Flow properties / Strömungsverhältnisse / Luftdata
200 250 300 350 400 450 500[m3/h]
Dry efficiency / WRG trocken / Tør virkningsgrad
89
91
87
85
83
81
Eta T [%] acc. EN 308 / Laut EN 308 / Jf. EN 308
Flow Pext. SFP P1 tot.[m3/h] [Pa] [J/m3] [W]200 70 900 50350 70 802 78450 70 832 104450 100 1080 135
Typical operation / Typische Arbeitspunkte
Typiske driftspunkter
By condensation up to 95%
Bei Kondensation bis zu 95%
Ved kondensering op til 95%
63
35
35
(1) Lw(A)
(2) Lw(A)
(3) Lp(A) Unit / Gerät / Anlæg til rum: 57
125
44
45
250
51
56
500
48
49
1000
48
47
2000
44
44
4000
31
31
Hz
dB(A)
dB(A)
dB(A)
63
39
39
(4) Lw(A)
(5) Lw(A)
(6) Lp(A) Unit / Gerät / Anlæg til rum: 61
125
47
48
250
61
62
500
55
55
1000
53
52
2000
48
50
4000
37
37
Hz
dB(A)
dB(A)
dB(A)
(1) Exhaust / Abluft / Udsugning @ 350 m3/h(2) Supply / Zuluft / Indblæsning @ 350 m3/h(3) Hard room / Harter raum / hårdt rum @ 350 m3/h
(4) Exhaust / Abluft / Udsugning @ 450 m3/h(5) Supply / Zuluft / Indblæsning @ 450 m3/h(6) Hard room / Harter raum / hårdt rum @ 450 m3/h
Danfoss Air a3
100%
SFP 1000 55%
79%
SFP 800
7VDEWA202
Danfoss A/SUlvehavevej 617100 Vejle
Tel. +45 74 88 85 00Fax +45 74 88 86 03www.danfoss.comwww.air-danfoss.com
Danfoss Air
5060708090
100110120130140150160170180190200
25 50 75 100 125 150 175 200 225 250 275 300
P ext. [Pa]
[m3/h]
SFP 1200
Flow properties / Strömungsverhältnisse / Luftdata
60 100 140 180 220 260 300[m3/h]
Dry efficiency / WRG trocken / Tør virkningsgrad
89
91
87
85
83
81
Eta T [%] acc. EN 308 / Laut EN 308 / Jf. EN 308
Flow Pext. SFP P1 tot.[m3/h] [Pa] [J/m3] [W]100 35 720 20100 55 792 22140 60 951 37140 70 1029 40180 70 1080 54180 100 1300 65
Typical operation / Typische Arbeitspunkte
Typiske driftspunkter
63
22
20
(1) Lw(A)
(2) Lw(A)
(3) Lp(A) Unit / Gerät / Anlæg til rum: 50
125
37
36
250
46
44
500
46
46
1000
43
43
2000
37
37
4000
25
26
Hz
dB(A)
dB(A)
dB(A)
63
34
31
(4) Lw(A)
(5) Lw(A)
(6) Lp(A) Unit / Gerät / Anlæg til rum: 55
125
43
42
250
50
47
500
51
50
1000
48
48
2000
42
42
4000
31
31
Hz
dB(A)
dB(A)
dB(A)
(1) Exhaust / Abluft / Udsugning @ 140 m3/h(2) Supply / Zuluft / Indblæsning @ 140 m3/h(3) Hard room / Harter raum / hårdt rum @ 140 m3/h
(4) Exhaust / Abluft / Udsugning @ 180 m3/h(5) Supply / Zuluft / Indblæsning @ 180 m3/h(6) Hard room / Harter raum / hårdt rum @ 180 m3/h
Danfoss Air w1
By condensation up to 95%
Bei Kondensation bis zu 95%
Ved kondensering op til 95%
100%
84%35%
SFP 1000
66%
5060708090
100110120130140150160170180190200
25 50 75 100 125 150 175 200 225 250 275 300
P ext. [Pa]
[m3/h]
100%
67%45%
82%
SFP 1200
SFP 1000
SFP 800
Flow properties / Strömungsverhältnisse / Luftdata
60 100 140 180 220 260 300[m3/h]
Dry efficiency / WRG trocken / Tør virkningsgrad
88
89
87
86
85
84
Eta T [%] acc. EN 308 / Laut EN 308 / Jf. EN 308
Flow Pext. SFP P1 tot.[m3/h] [Pa] [J/m3] [W]160 50 720 32220 70 867 53220 100 1047 64260 70 997 72260 100 1163 84300 90 1200 100
Typical operation / Typische Arbeitspunkte
Typiske driftspunkter
By condensation up to 95%
Bei Kondensation bis zu 95%
Ved kondensering op til 95%
63
30
25
(1) Lw(A)
(2) Lw(A)
(3) Lp(A) Unit / Gerät / Anlæg til rum: 60
125
41
42
250
47
52
500
48
50
1000
46
48
2000
42
44
4000
32
34
Hz
dB(A)
dB(A)
dB(A)
63
33
28
(4) Lw(A)
(5) Lw(A)
(6) Lp(A) Unit / Gerät / Anlæg til rum: 63
125
46
46
250
57
55
500
57
54
1000
55
52
2000
51
48
4000
43
40
Hz
dB(A)
dB(A)
dB(A)
(1) Exhaust / Abluft / Udsugning @ 220 m3/h(2) Supply / Zuluft / Indblæsning @ 220 m3/h(3) Hard room / Harter raum / hårdt rum @ 220 m3/h
(4) Exhaust / Abluft / Udsugning @ 260 m3/h(5) Supply / Zuluft / Indblæsning @ 260 m3/h(6) Hard room / Harter raum / hårdt rum @ 260 m3/h
Danfoss Air w2
www.danfoss.comVDEWA102 A1.02