RESIDENTIAL ADDITION 6230 SARATOGA CIRCLE DALLAS, TX 75214 G1.0 COVER SHEET & SURVEY INDICATES WRITTEN REVISION INDICATES REVISION ON 8 1/2 X 11 SHEET LEGEND 01.29.16 SURVEY COVER SHEET & G1.0 01 1:20 SCALE EXISTING SURVEY ORIGINAL ISSUE DATE SHEET IN ISSUE REVISION NUMBER LATEST ISSUE DATE APPLICABLE CODES BUILDING CODE: 2012 INTERNATIONAL RESIDENTIAL BUILDING CODE PLUMBING CODE: 2012 INTERNATIONAL PLUMBING CODE MECHANICAL CODE: 2012 INTERNATIONAL MECHANICAL CODE FIRE CODE: 2012 INTERNATIONAL FIRE CODE ELECTRICAL CODE: 2014 NATIONAL ELECTRICAL CODE ENERGY CODE: 2009 INTERNATIONAL ENERGY CONSERVATION CODE GAS CODE: 2012 INTERNATIONAL FUEL & GAS CODE DRAWING INDEX ZONING INFORMATION A2.1 EXTERIOR ELEVATIONS A3.1 LIGHTING/POWER PLAN A1.1 FLOOR PLAN A5.1 DOOR /WINDOW TYPES & SCHEDULES (WITH CITY OF DALLAS AMENDMENTS) (WITH CITY OF DALLAS AMENDMENTS) (WITH CITY OF DALLAS AMENDMENTS) (WITH CITY OF DALLAS AMENDMENTS) (WITH CITY OF DALLAS AMENDMENTS) (WITH CITY OF DALLAS AMENDMENTS) (WITH CITY OF DALLAS AMENDMENTS) EXISTING HOME AREA: 1,731 SF NEW ADDITION: 1,469 SF 3,200 SF TOTAL GARAGE AREA: 557 SF EXISTING LOT AREA: 11,378 SF (0.26 ACRES) (PER DCAD) NEW BUILDING FOOT PRINT: 3,757 SF NEW LOT COVERAGE: 33% LOT 20 BLOCK 4/2954 CARUTH TERRACE DALLAS, DALLAS COUNTY, TEXAS LOT AREA: 11,378 SF FRONTAGE: 70' LOT DEPTH: 135' LOT COVERAGE: MAX 45% DENSITY: 1 UNIT /7,500 SF HEIGHT: MAX 30' FRONT YARD SETBACK: 25' SIDE YARD SETBACK: 5' REAR YARD SETBACK: 5' ZONING CLASSIFICATION: R-7.5A PROJECT AREA 1. THE ARCHITECTURAL DRAWINGS ARE TO BE USED IN CONJUNCTION WITH STRUCTURAL DRAWINGS, HVAC DRAWINGS, AND THOSE OF ANY OTHER TRADE APPLICABLE TO THE PROJECT. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL COORDINATION BETWEEN THE DRAWINGS AND WORK OF ALL THE TRADES. DISCREPANCIES SHOULD BE BROUGHT TO THE ATTENTION OF THE OWNER AND/OR SIDEBAR COLLABORATIVE. 2. CONTRACTOR TO VERIFY ALL FIELD CONDITIONS. THE CONTRACTOR SHALL NOTIFY THE OWNER AND/OR SIDEBAR COLLABORATIVE OF ANY DISCREPANCIES IN DIMENSIONS PRIOR TO PROCEEDING WITH WORK IN THAT AREA. 3. ALL CONSTRUCTION STANDARDS AND DEMOLITION TO BE APPLICABLE UNDER LOCAL, STATE, AND FEDERAL CODES, STATUTES, ETC. ANY VARIATION TO BE REPORTED IMMEDIATELY TO SIDEBAR COLLABORATIVE. 4. DO NOT SCALE DRAWINGS: WRITTEN DIMENSIONS GOVERN. IN CASE OF CONFLICT, NOTIFY SIDEBAR COLLABORATIVE FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING. 5. THE GENERAL CONTRACTOR SHALL COORDINATE CONSTRUCTION MATERIAL DELIVERY TIMES WITH OWNER. 6. THE GENERAL CONTRACTOR SHALL COORDINATE LOCATION OF CONSTRUCTION MATERIAL LAY-DOWN AND STORAGE AREA WITH OWNER. 7. HVAC, PLUMBING, AND ELECTRICAL SYSTEMS TO BE DESIGNED BY OTHERS. 8. CONTRACTOR TO NOTIFY SIDEBAR COLLABORATIVE OF ANY DISCREPANCIES BETWEEN FIELD CONDITIONS, STRUCTURAL FOUNDATION DESIGN, AND ARCHITECTURAL DESIGN PRIOR TO PROCEEDING WITH WORK. 9. 3RD PARTY ENERGY/GREEN CODE COMPLIANCE CHECK BY OTHERS. 10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROMPT REPAIR OF DAMAGES CAUSED TO ADJACENT FACILITIES BY DEMOLITION. 11. PROVIDE PROTECTION TO PERSONS AND PROPERTY. EXECUTE THE WORK SO AS TO AVOID INTERFERENCE WITH ADJACENT SPACES AND PROPERTIES. 12. THE GENERAL CONTRACTOR IS TO COORDINATE AND FOLLOW ALL CONSTRUCTION PROCEDURES REQUIRED BY THE CITY OF DALLAS INCLUDING, TIMES OF WORK, SITE ACCESS, ETC. 13. ALL WORK TO MEET APPLICABLE BUILDING CODES, PER THE REQUIREMENTS OF THE LOCAL JURISDICTION. 14. PRIOR TO DEMOLITION, VERIFICATION OF THE EXISTENCE OF ASBESTOS MATERIAL OR LEAD PAINT WILL NEED TO BE OBTAINED BY A LICENSED PROFESSIONAL. IF PRESENT, REMOVAL OF SUCH ITEMS SHALL CONFORM TO ALL LOCAL AND STATE CODES. GENERAL NOTES ***FOR REFERENCE ONLY*** INFORMATION BASED ON LAND SURVEY DATED 08/07/2014 A4.1 INTERIOR ELEVATIONS GREEN CODE: 2012 INTERNATIONAL GREEN CONSTRUCTION CODE (WITH CITY OF DALLAS AMENDMENTS) ARCHITECTURAL SIDEBAR COLLABORATIVE, PLLC 2201 Primrose Ave. Fort Worth, TX 76111 Contact: J. Scott Slagle, AIA 214.405.9613 [email protected] ARCHITECT CONTACTS 6230 Saratoga Circle Dallas, TX 75214 Contact: Jeff Strasner [email protected] 214.220.7101 OWNER A4.2 INTERIOR ELEVATIONS SP1.0 SITE PLAN & DEMO PLAN ISSUED FOR CONSTRUCTION REVISIONS Item Date No. Project No. Date Last Revision 15014.00 6230 SARATOGA CIRCLE ADDITION & REMODEL DALLAS, TX 75214 S I DEBAR COLLABORAT I VE , PLLC 01.29.16 2201 PR I MROSE AVE / FORT WORTH , TX 76111 / 214 . 405 . 9613 / s i debarco l ab . com 01.29.16 01.29.16 01.29.16 01.29.16 01.29.16 01.29.16 01.29.16 01.29.16

Transcript of DALLAS, TX 75214 6230 SARATOGA...

Page 1: DALLAS, TX 75214 6230 SARATOGA CIRCLEstorage.cloversites.com/bluestonepartnersllc/documents/Strasner... · building code: 2012 international residential building code plumbing code

RESIDENTIAL ADDITION

6230 SARATOGA CIRCLE DALLAS, TX 75214

G1.0 COVER SHEET & SURVEY

INDICATES WRITTEN REVISION

INDICATES REVISION ON 8 1/2 X 11 SHEET

LEGEND

01.29.16

SURVEYCOVER SHEET &

G1.001

1:20 SCALE

EXISTING SURVEY

ORIGINAL ISSUE DATE

SHEET IN ISSUE

REVISION NUMBER

LATEST ISSUE DATE

APPLICABLE CODES

BUILDING CODE: 2012 INTERNATIONAL RESIDENTIAL BUILDING CODE

PLUMBING CODE: 2012 INTERNATIONAL PLUMBING CODE

MECHANICAL CODE: 2012 INTERNATIONAL MECHANICAL CODE

FIRE CODE: 2012 INTERNATIONAL FIRE CODE

ELECTRICAL CODE: 2014 NATIONAL ELECTRICAL CODE

ENERGY CODE: 2009 INTERNATIONAL ENERGY CONSERVATION CODE

GAS CODE: 2012 INTERNATIONAL FUEL & GAS CODE

DRAWING INDEX

ZONING INFORMATION

A2.1 EXTERIOR ELEVATIONS

A3.1 LIGHTING/POWER PLAN

A1.1 FLOOR PLAN

A5.1 DOOR /WINDOW TYPES & SCHEDULES

(WITH CITY OF DALLAS AMENDMENTS)

(WITH CITY OF DALLAS AMENDMENTS)

(WITH CITY OF DALLAS AMENDMENTS)

(WITH CITY OF DALLAS AMENDMENTS)

(WITH CITY OF DALLAS AMENDMENTS)

(WITH CITY OF DALLAS AMENDMENTS)

(WITH CITY OF DALLAS AMENDMENTS)

EXISTING HOME AREA: 1,731 SFNEW ADDITION: 1,469 SF 3,200 SF TOTAL

GARAGE AREA: 557 SF

EXISTING LOT AREA: 11,378 SF (0.26 ACRES) (PER DCAD)NEW BUILDING FOOT PRINT: 3,757 SFNEW LOT COVERAGE: 33%

LOT 20BLOCK 4/2954 CARUTH TERRACEDALLAS, DALLAS COUNTY, TEXAS

LOT AREA: 11,378 SFFRONTAGE: 70'LOT DEPTH: 135'LOT COVERAGE: MAX 45%DENSITY: 1 UNIT /7,500 SFHEIGHT: MAX 30'

FRONT YARD SETBACK: 25'SIDE YARD SETBACK: 5'REAR YARD SETBACK: 5'

ZONING CLASSIFICATION: R-7.5A

PROJECT AREA

1. THE ARCHITECTURAL DRAWINGS ARE TO BE USED IN CONJUNCTION WITH STRUCTURAL DRAWINGS, HVACDRAWINGS, AND THOSE OF ANY OTHER TRADE APPLICABLE TO THE PROJECT. THE GENERAL CONTRACTOR ISRESPONSIBLE FOR ALL COORDINATION BETWEEN THE DRAWINGS AND WORK OF ALL THE TRADES. DISCREPANCIESSHOULD BE BROUGHT TO THE ATTENTION OF THE OWNER AND/OR SIDEBAR COLLABORATIVE.

2. CONTRACTOR TO VERIFY ALL FIELD CONDITIONS. THE CONTRACTOR SHALL NOTIFY THE OWNER AND/OR SIDEBARCOLLABORATIVE OF ANY DISCREPANCIES IN DIMENSIONS PRIOR TO PROCEEDING WITH WORK IN THAT AREA.

3. ALL CONSTRUCTION STANDARDS AND DEMOLITION TO BE APPLICABLE UNDER LOCAL, STATE, AND FEDERAL CODES,STATUTES, ETC. ANY VARIATION TO BE REPORTED IMMEDIATELY TO SIDEBAR COLLABORATIVE.

4. DO NOT SCALE DRAWINGS: WRITTEN DIMENSIONS GOVERN. IN CASE OF CONFLICT, NOTIFY SIDEBAR COLLABORATIVEFOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING.

5. THE GENERAL CONTRACTOR SHALL COORDINATE CONSTRUCTION MATERIAL DELIVERY TIMES WITH OWNER.

6. THE GENERAL CONTRACTOR SHALL COORDINATE LOCATION OF CONSTRUCTION MATERIAL LAY-DOWN AND STORAGEAREA WITH OWNER.

7. HVAC, PLUMBING, AND ELECTRICAL SYSTEMS TO BE DESIGNED BY OTHERS.

8. CONTRACTOR TO NOTIFY SIDEBAR COLLABORATIVE OF ANY DISCREPANCIES BETWEEN FIELD CONDITIONS,STRUCTURAL FOUNDATION DESIGN, AND ARCHITECTURAL DESIGN PRIOR TO PROCEEDING WITH WORK.

9. 3RD PARTY ENERGY/GREEN CODE COMPLIANCE CHECK BY OTHERS.

10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROMPT REPAIR OF DAMAGES CAUSED TO ADJACENTFACILITIES BY DEMOLITION.

11. PROVIDE PROTECTION TO PERSONS AND PROPERTY. EXECUTE THE WORK SO AS TO AVOID INTERFERENCE WITHADJACENT SPACES AND PROPERTIES.

12. THE GENERAL CONTRACTOR IS TO COORDINATE AND FOLLOW ALL CONSTRUCTION PROCEDURES REQUIRED BY THECITY OF DALLAS INCLUDING, TIMES OF WORK, SITE ACCESS, ETC.

13. ALL WORK TO MEET APPLICABLE BUILDING CODES, PER THE REQUIREMENTS OF THE LOCAL JURISDICTION.

14. PRIOR TO DEMOLITION, VERIFICATION OF THE EXISTENCE OF ASBESTOS MATERIAL OR LEAD PAINT WILL NEED TO BE OBTAINED BY A LICENSED PROFESSIONAL. IF PRESENT, REMOVAL OF SUCH ITEMS SHALL CONFORM TO ALL LOCAL AND STATE CODES.

GENERAL NOTES

***FOR REFERENCE ONLY*** INFORMATION BASED ON LAND SURVEY DATED 08/07/2014

A4.1 INTERIOR ELEVATIONS

GREEN CODE: 2012 INTERNATIONAL GREEN CONSTRUCTION CODE(WITH CITY OF DALLAS AMENDMENTS)

ARCHITECTURAL

SIDEBAR COLLABORATIVE, PLLC2201 Primrose Ave.Fort Worth, TX 76111Contact: J. Scott Slagle, [email protected]

ARCHITECT

CONTACTS

6230 Saratoga CircleDallas, TX 75214Contact: Jeff [email protected]

OWNER

A4.2 INTERIOR ELEVATIONS

SP1.0 SITE PLAN & DEMO PLAN

MM.DD.YY

MM.DD.YY

TITLESHEET

A0.00

XXX

XXX

XXX

ISSU

ED F

OR C

ONST

RUCT

ION

REVISIONS

ItemDateNo.

Project No.DateLast Revision

15014.00

6230

SAR

ATOG

A CI

RCLE

ADDI

TION

& R

EMOD

ELDA

LLAS

, TX

7521

4

SIDEBAR

COLLAB

ORATIVE, P

LLC

01.29.16

2201 PR

IMROSE

AVE / FOR

T WORT

H, TX 761

11 / 214.4

05.9613

/ sidebarcolla

b.com

THE REEDY GROUP4434 West Lovers LaneDallas, TX 75209Contact: Frank Reedy, [email protected]

01.29.16

01.29.16

01.29.16

01.29.16

01.29.16

01.29.16

01.29.16

01.29.16

Page 2: DALLAS, TX 75214 6230 SARATOGA CIRCLEstorage.cloversites.com/bluestonepartnersllc/documents/Strasner... · building code: 2012 international residential building code plumbing code

DEMO NOTES

1. WORK INCLUDES BUT IS NOT LIMITED TO THAT INDICATED IN THE DEMOLITION NOTES OR DRAWINGS. IT IS THERESPONSIBILITY OF THE GENERAL CONTRACTOR TO REVIEW ALL DRAWINGS AND VISIT THE SITE IN ORDER TODETERMINE THE FULL SCOPE OF THE DEMOLITION WORK.

2. PRIOR TO DEMOLITION, VERIFICATION OF THE EXISTENCE OF ASBESTOS MATERIAL OR LEAD PAINT WILL NEED TO BEOBTAINED BY A LICENSED PROFESSIONAL. IF PRESENT, REMOVAL OF SUCH ITEMS SHALL CONFORM TO ALL LOCALAND STATE CODES.

3. CONFIRM THAT ALL WALLS ARE NOT LOAD BEARING PRIOR TO THEIR DEMOLITION AND REMOVAL.

4. PROVIDE ALL NECESSARY SHORING, BRACING, AND/OR SUPPORT TO PREVENT MOVEMENT, SETTLEMENT OR COLLAPSEOF STRUCTURES TO BE DEMOLISHED.

5. DEMOLISH ALL WALLS AS SHOWN. PATCH AND REPAIR ALL EXISTING WALLS TO REMAIN AND PREPARE FOR NEWFINISHES.

6. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROMPT REPAIR OF DAMAGES CAUSED TO ADJACENTFACILITIES BY DEMOLITION OPERATIONS AT NO COST TO THE OWNER.

7. PROVIDE PROTECTION TO PERSONS AND PROPERTY. EXECUTE THE WORK SO AS TO AVOID INTERFERENCE WITHADJACENT SPACES THAT REMAIN IN OPERATION.

8. ALL DEMOLITION WORK, UNO, SHALL BECOME THE PROPERTY OF THE GENERAL CONTRACTOR AND SHALL BEREMOVED FROM THE SITE AND LEGALLY DISPOSED OF DAILY.

9. ALL WORK TO REMAIN INCLUDING WALLS, COLUMNS, BEAMS AND OTHER STRUCTURAL ELEMENTS NOTED AS TOREMAIN SHALL BE PROTECTED DURING DEMOLITION AND NEW WORK.

10. ITEMS TO BE SALVAGED AND RELOCATED ARE TO BE PREPARED FOR REUSE AND STORED IN A SECURE, DRYENVIRONMENT UNTIL THE TIME OF INSTALLATION.

11. WHERE FLOORING IS REMOVED, REMOVE ALL GLUE, TACKS, SETTING BEDS, ETC. AND PROVIDE SMOOTH, CLEANED,AND LEVEL FLOOR SURFACE, PREPPED FOR NEW FINISHES.ITEMS TO BE SALVAGED AND RELOCATED ARE TO BEPREPARED FOR REUSE AND STORED IN A SECURE, DRY ENVIRONMENT UNTIL THE TIME OF INSTALLATION.

12. COORDINATE SHUT-OFF AND DISCONNECT OF UTILITIES TO HOME PRIOR TO DEMOLITION.

13. ALL DEMOLITION TO MEET LOCAL CODES AND ORDINANCES.

SITE NOTES

1. WORK INCLUDES BUT IS NOT LIMITED TO THAT INDICATED IN THE SITE NOTES OR DRAWINGS. IT IS THERESPONSIBILITY OF THE GENERAL CONTRACTOR TO REVIEW ALL DRAWINGS AND VISIT THE SITE IN ORDER TODETERMINE THE FULL SCOPE OF THE SITE WORK.

2. VERIFY ALL EXISTING CONDITIONS IN FIELD.

3. PROVIDE ALL NECESSARY SHORING, BRACING, AND/OR SUPPORT TO PREVENT MOVEMENT, SETTLEMENT OR RUNOFFOF DIRT WORK WHEN RETAINING WALL IS REMOVED.

4. PAVING SECTIONS, GRADING, AND DRAINAGE DESIGN BY OTHERS.

5. COORDINATE EXTENT OF LANDSCAPE REMOVAL WITH OWNER PRIOR TO CONSTRUCTION.

6. PROVIDE PROTECTION TO PERSONS AND PROPERTY. EXECUTE THE WORK SO AS TO AVOID INTERFERENCE WITHADJACENT SPACES AND STREETS THAT REMAIN IN OPERATION.

7. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE AND PROTECT ANY EXISTING UNDERGROUND OROVERHEAD UTILITIES.

1

KEY NOTES

GC TO COORDINATE TEMPORARY POWER FOR EXISTING HOME TO REMAIN IN OPERATION DURINGCONSTRUCTION. COORDINATE PHASING WITH OWNER & ARCHITECT.

2

GC TO COORDINATE OVERHEAD ELECTRICAL SERVICE WITH FRANCHISE UTILITY. VERIFY LOCATION OFEXISTING POLE. CONSTRUCTION. NEW POLE MAY BE REQUIRED TO PREVENT CONFLICT BETWEEN NEWGARAGE AND OVERHEAD POWER THAT CROSSES PROPERTY TO REACH NEIGHBORING RESIDENCE.

3

LOCATE AND DEMO PORTIONS OF EXISTING SPRINKLER SYSTEM IN CONFLICT WITH NEW ADDITION.PREPARE FOR RECONFIGURATION. CONTROLS TO BE RELOCATED TO NEW GARAGE.

NEW LOCATION FORELECTRICAL METER

NEW HVAC CONDENSINGUNIT; DESIGN BY OTHERS

3'-6"1'-6"1'-6"

RELOCATED CONDENSINGUNIT; TO BE RECONNECTEDTO EXISTING SYSTEM; DESIGNBY OTHERS

ADDITION

EXISTING

10'-0

"

EXISTINGHOME

N 74° 16' 15" E

N 15°

43' 4

5" W

S 15°

43' 4

5" E

S 82° 06' 33" W

ALLEY EXISTING POWER POLE

NEW

OVER

HEAD

POWE

R

EXISTING GAS METER

NEWADDITION

SLOPE 4:12MATCH EXIST., VIF

SLOPE 4:12MATCH EXIST., VIF

SLOPE 4:12

SLOP

E 4:12

SLOP

E 4:12

SLOP

E 4:12

LINE OF BUILDING BELOW

2'-0"

2'-0"

2'-0"

2'-0"

2'-0"

LANDSCAPING BY OTHERS

LANDSCAPINGBY OTHERS

NEW CHAINLINK GATE

EXISTING GATE TO REMAIN

LANDSCAPINGBY OTHERS

NEW CONCRETE DRIVE

EXISTING CONCRETE DRIVE

EXIST

ING CO

NCRE

TE DR

IVE5'

SIDEY

ARD S

ETBA

CK

5' SID

EYAR

D SET

BACK

5' REARYARD SETBACK

PATCH & TIE-INNEW AND OLD ROOFTO PROVIDE COMPLETESYSTEM

REMOVE EXISTING HVAC EQUIPMENTAND RELOCATE PER NEW WORK PLAN;

VERIFY CONDITION OF SYSTEM FORPOSSIBILITY OF REUSE.

DEMO EXISTINGCONCRETE PAD

DEMO EXISTING EXTERIORBRICK WALL AS REQUIRED

FOR NEW ADDITIONDEMO EXISTING EXTERIORWALL AS REQUIRED FOR NEWADDITION

DEMO EXISTINGCONCRETE SLAB &

FOUNDATION

RELOCATE EXISTING SWITCHES;COORDINATE WITH NEW WORK PLAN

REMOVE EXISTING HOT WATER HEATERAND RELOCATE PER NEW WORK PLAN

PROVIDE TEMPORARY WALL FORSEPARATION DURING CONSTRUCTION

PHASE CONSTRUCTION TO ALLOW EXISTING WASHERAND DRYER TO REMAIN OPERABLE AS LONG ASPOSSIBLE; RELOCATE PER NEW WORK PLAN

*** CLEAN AND PREPARE EXTERIOR BRICK OF ENTIRE HOME TO RECEIVE NEW PAINT***

*** PREPARE TRIM AROUND ALL EXISTING WINDOWS TO RECEIVE NEW PAINT***

GENERAL NOTES THROUGHOUT

DEMO EXISTING TREE

DEMO EXISTINGCONCRETE STEPS

DEMO EXISTING GARAGE DOORAND ASSOCIATED ELECTRICAL

DEMO EXISTING CONCRETEPATIO; REFERENCE NEW

WORK PLAN FOR EXTENTS

DEMO EXISTING CONCRETE DRIVEWAY;REFERENCE NEW WORK PLAN FOR EXTENTS

INVESTIGATE LOCATION OF EXISTING BEAM ANDSUPPORTS; COORDINATE WITH ARCHITECT

DEMO EXISTING EXTERIORWALL AS REQUIRED FOR NEWADDITION

*** LOCATE EXISTING UTILITY LINES PRIOR TO NEW WORK; RELOCATE AS REQUIRED***

RELOCATE XISTING ELECTRICALUTILITY METER; COORDINATE

WITH NEW WORK PLAN

EXISTING HOMEAREA NOT IN SCOPE

N 74° 16' 15" E

N 15°

43' 4

5" W

S 15°

43' 4

5" E

S 82° 06' 33" W

ALLEYEXISTING GAS METER

15'-4"

30'-4

"

EXISTING TREE TO REMAIN

EXIST

ING CO

NCRE

TE DR

IVE5'

SIDEY

ARD S

ETBA

CK

5' SID

EYAR

D SET

BACK

5' REARYARD SETBACK

EXISTING WOOD FENCEEXISTING CHAINLINK FENCE

EXISTING CHAINLINK FENCE

EXISTING WOOD FENCE

EXISTI

NG OV

ERHEAD

POWER

TO NEI

GHBO

R

EXISTING OVERHEAD POWER TO BE RELOCATED

EXISTING ELECTRICAL POLE

3

2

1

VERIFY LOCATION IS NOT INCONFLICT WITH NEW GARAGE*VERIFY AND COORDINATEW/FRANCHISE UTILITY

01.29.16

& DEMOLITION PLANARCHITECTURAL SITE PLAN

SP1.002

Scale: 1/8" = 1'-0"

SITE PLAN MM.DD.YY

MM.DD.YY

TITLESHEET

A0.00

XXX

XXX

XXX

ISSU

ED F

OR C

ONST

RUCT

ION

REVISIONS

ItemDateNo.

Project No.DateLast Revision

15014.00

6230

SAR

ATOG

A CI

RCLE

ADDI

TION

& R

EMOD

ELDA

LLAS

, TX

7521

4

SIDEBAR

COLLAB

ORATIVE, P

LLC

01.29.16

2201 PR

IMROSE

AVE / FOR

T WORT

H, TX 761

11 / 214.4

05.9613

/ sidebarcolla

b.com

THE REEDY GROUP4434 West Lovers LaneDallas, TX 75209Contact: Frank Reedy, [email protected]

01Scale: 1/8" = 1'-0"

DEMO PLAN

Page 3: DALLAS, TX 75214 6230 SARATOGA CIRCLEstorage.cloversites.com/bluestonepartnersllc/documents/Strasner... · building code: 2012 international residential building code plumbing code

TV

54'-0

"

5'-4"

48'-8

"

1'-4"

5'-4"

2'-0"

5'-6"

1'-2"

2'-8"

9'-4"

2'-8"

18'-8

"

58'-0"

32'-0"

12'-0" 10'-0" 8'-8" 1'-4"

26'-8

"

35'-4"

28'-0

"

2'-0"

2'-0" 18'-0" 5'-4" 4'-0" 8"4'-0"1'-4"

4'-0"

1'-4"

14'-8

"1'-

4"

20'-1 5/8" 10'-4 1/4"

16'-8

1/2"

2'-8" 4'-8"1'-4" 2'-8" 4'-8" 2'-8" 7'-4"

3'-0"

7'-4 1/2" 6'-6 3/8"

6'-0"

3'-6"

1'-6"

4'-0" 1'-6" 1'-6" 9'-0"104

FAMILY ROOM102

MASTERBEDROOM

104

CORRIDOR103

CORRIDOR101

BREAKFASTNOOK

100

MASTERCLOSET

107

MUDROOM108

GARAGE109

MASTERBATH

105

ALIGN

05 / A

4.1

06 / A

4.1

08 / A4.2

07 / A

4.209

/ A4.2

09/ A

4.2 O.

H.

05 / A

4.2

06 / A4.2

02 / A

4.2

03 / A

4.2

04 / A4.201 / A4.2

10 / A

4.2

04 / A4.1

2'-0"

4'-0"

2'-0 1

/2"13

'-9 1/

2"

2'-1"

3'-9"

MECH110

102

105

106 TOILET106

107

108

109 113

112

110

111

98'-9" FF (VIF)

98'-9" FF (VIF) 100'-0" FF

100'-0" FF

03 A2

.1

01 / A

2.1

02 / A2.1

04 / A2.1

SC-1

WD-1

WD-1

WD-1

FT-1

FT-2

FT-3

AA

WATERHEATER

REFRIGERATOR

WASHER

DRYER

B

C

D

BE

F

WD-1

DOWN

WC- 1

LAV- 1

LAV- 1

TUB- 1

07/ A

4.1

KITCHENE103

LIVING ROOME102

EXISTING WINDOW TO REMAIN

03 / A4.1

08 / A

4.1

01 / A4.1

02/ A2.1

ADDIT

IONEX

ISTING

02 / A4.1

WD-1

WD-1

WD-1

4'-0"

3'-0"

3'-6"

4"

2'-3"

2'-1"

6"

6'-2"

A

A

A

B

E

101

WD-2WD-2

114

01

01

02

02

04

031'-0"

1'-6 1/2"

2'-0"

ALIGN

MIRR

OR FA

CE

ALIGN

5'-0" 5'-0"

2'-0" 1'-

0"

4'-0"CLEAR

05

06

LEGENDDESCRIPTIONSYMBOL

AREA NOT IN SCOPE, UNO

NEW PARTITION

DOOR NUMBER

00/X-000 ELEVATION MARKER

DESCRIPTIONSYMBOL

WINDOW MARKER

NEW DOOR

XX

XX

1. ALL DIMENSIONS ARE FROM FINISH FACE, U.N.O.

2. GC TO VERIFY WALL LAYOUT WITH OWNER AND ARCHITECT PRIOR TO INSTALLATION.

3. GC TO COORDINATE HVAC SUPPLY AND RETURN DIFFUSER LOCATIONS AND ACCESS DOORSWITH ARCHITECT PRIOR TO INSTALLATION.

4. ALL EXTERIOR WALLS TO RECEIVE SPRAY FOAM INSULATION TO YIELD A VALUE OF R-20.

5. ROOF TO RECEIVE SPRAY FOAM INSULATION THROUGHOUT TO YIELD A VALUE OF R-38.

6. FIRST FLOOR TO RECEIVE SPRAY FOAM INSULATION TO YIELD A VALUE OF R-19.

7. ALL NEW WALLS TO RECEIVE 12" GYP. BD. EXCEPT IN WET LOCATIONS. WET LOCATIONS TORECEIVE 12 " CEMENTITIOUS TILE BACKER BOARD. ALL GYP. BD. IN DAMP LOCATIONS SHALLRECEIVE WATER RESISTANT GYP. BD. ALL NEW WALLS TO RECEIVE PAINT. COLORS TBD BYOWNER.

8. ALL WALL MOUNTED ITEMS SUCH AS MILLWORK, FURNITURE, OWNER PROVIDED EQUIPMENT,ETC SHALL BE REINFORCED WITH BRACING, BLOCKING, AND/OR STRUCTURE AS REQUIRED.

9. IT IS THE INTENT OF THE DRAWINGS THAT ALL EXPOSED SURFACES RECEIVE FINISHES ASINDICATED ON THE DRAWINGS, U.N.O.

10. THE GENERAL CONTRACTOR SHALL COORDINATE AND CONFIRM COMPATIBILITY OF ALL FINISHES,MATERIALS, SEALANTS, SEALERS, PAINTS, ADHESIVES, ETC. WITH SUBSTRATES, EXISTINGMATERIALS, ADJACENT MATERIALS, ETC. NOTIFY SIDEBAR COLLABORATIVE OF ANYDISCREPANCIES IN FIELD PRIOR TO PROCEEDING.

11. ALL FLOOR TRANSITIONS OCCURRING AT DOORS SHALL OCCUR AT THE CENTERLINE OF THEDOOR, U.N.O.

12. ALL JOINTS, SCREWS OR OTHER DEPRESSIONS IN SURFACE OF GYPSUM BOARD SHALL BETREATED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. ALL JOINTS, U.N.O.,SHALL BE TAPED, BEDDED, AND SANDED, PARTITIONS SHALL HAVE A SMOOTH SURFACE TORECEIVE FINISH WALL TREATMENT.

13. ALL VERTICAL AND HORIZONTAL EXTERNAL CORNERS OF GYPSUM BOARD SHALL HAVE CORNERREINFORCEMENTS PROVIDED. INSTALL CORNER BEADS WITH SUITABLE FASTENERS. INSTALLCASING BEADS WHERE GYPSUM SURFACES TERMINATE OR MEET DISSIMILAR MATERIALS.

14. FINISHED DRYWALL CONSTRUCTION SHALL BE OF A LEVEL FOUR FINISH AND FREE OFNOTICEABLE DEFECTS WHICH INCLUDE JOINT RIDGING, STAVED JOINTS, BOARD EDGESDAMAGED OR OUT OF PLACE, JOINT BLISTERS, SCREW POPS, PIN HOLES IN JOINT TREATMENT ORANY OTHER NOTICEABLE DEFECTS. FINISH WALLS HALL BE TRUE TO LINE, PERFECTLY SMOOTHAND READY TO RECEIVE FINISHED MATERIAL.

15. ALL INTERIOR DOORS TO BE SOLID CORE WOOD, U.N.O.

16. ALL ROOMS TO RECEIVE 4" PAINTED BASE, U.N.O.; VIF TO MATCH EXISTING.

17. REFER TO SHEET A5.1 FOR FINISH SCHEDULES.

CONSTRUCTION/FINISH NOTES

00/X-000SECTION MARKER

01 PIER & BEAM FLOOR SYSTEM

02 SLAB ON GRADE

KEY NOTES

03 BUILT-IN SHOWER BENCH W/ TILE

04 WATER HEATER TO BE SIZED BY MECHANICAL SUB-CONTRACTOR

05 ACOUSTICAL WALL PARTITION; REFERENCE PLAN DETAIL ON SHEET A5.1

06 PRICE AS ALTERNATE FURNITURE BASED CLOSET SYSTEM; DESIGN BASIS ELFA OR SIMILAR

01.29.16

FLOOR PLAN

A1.101

Scale: 1/4" = 1'-0"

FLOOR PLAN MM.DD.YY

MM.DD.YY

TITLESHEET

A0.00

XXX

XXX

XXX

ISSU

ED F

OR C

ONST

RUCT

ION

REVISIONS

ItemDateNo.

Project No.DateLast Revision

15014.00

6230

SAR

ATOG

A CI

RCLE

ADDI

TION

& R

EMOD

ELDA

LLAS

, TX

7521

4

SIDEBAR

COLLAB

ORATIVE, P

LLC

01.29.16

2201 PR

IMROSE

AVE / FOR

T WORT

H, TX 761

11 / 214.4

05.9613

/ sidebarcolla

b.com

THE REEDY GROUP4434 West Lovers LaneDallas, TX 75209Contact: Frank Reedy, [email protected]

Page 4: DALLAS, TX 75214 6230 SARATOGA CIRCLEstorage.cloversites.com/bluestonepartnersllc/documents/Strasner... · building code: 2012 international residential building code plumbing code

107'-4" AFF - SOFFIT (VIF)

PAINTED HARDIE BOARD FASCIA BOARD

98'-9", VIF LOWER LEVEL(SLAB ON GRADE)

100'-0" FINISHED FLOOR

COMPOSITE SHINGLES,TO MATCH EXISTING

PAINTED HARDIE BOARD SOFFITPAINTED HARDIE TRIM BOARD

(PIER AND BEAM)

BRICK SOLDIER COURSE, TYPTO MATCH EXISTING

RUNNING BOND BRICK , TYPTO MATCH EXISTING

ROWLOCK SILL , TYPTO MATCH EXISTING

CONCRETE STEPS

ADDITION EXISTING

COMPOSITE SHINGLES,TO MATCH EXISTING

GUTTERS AROUND FASCIA, TYPTO MATCH EXISTING

GUTTERS AROUND FASCIA, TYPTO MATCH EXISTING

3 HEADER BRICK (STACKED)ADJACENT TO WINDOWS, TYPTO MATCH EXISTING

107'-4" AFF - SOFFIT (VIF)

PAINTED HARDIE BOARD FASCIA BOARD

98'-9", VIF LOWER LEVEL(SLAB ON GRADE)

100'-0" FINISHED FLOOR

COMPOSITE SHINGLES,TO MATCH EXISTING

PAINTED HARDIE BOARD SOFFIT AND VENTSPAINTED HARDIE TRIM BOARD

(PIER AND BEAM)

COMPOSITE SHINGLES,TO MATCH EXISTING

GUTTERS AROUND FASCIA, TYPTO MATCH EXISTING

ROWLOCK SILL , TYPTO MATCH EXISTING

3 HEADER BRICK (STACKED)ADJACENT TO WINDOWS, TYP

TO MATCH EXISTING

AUTOMATIC GARAGE DOOR

FAMILYROOM

02/A5.1 SIM

107'-4" AFF - SOFFIT (VIF)

PAINTED HARDIE BOARD FASCIA BOARD

98'-9", VIF LOWER LEVEL(SLAB ON GRADE)

100'-0" FINISHED FLOOR

COMPOSITE SHINGLES,TO MATCH EXISTING

PAINTED STEEL POST

PAINTED HARDIE BOARD SOFFIT AND VENTSPAINTED HARDIE TRIM BOARD

BRICK SOLDIER COURSE,TO MATCH EXISTING

BRICK SOLDIER COURSE, TYPTO MATCH EXISTING

RUNNING BOND BRICK , TYPTO MATCH EXISTING

ROWLOCK SILL , TYPTO MATCH EXISTING

ADDITIONEXISTING

COMPOSITE SHINGLES,TO MATCH EXISTING

EXPOSED FOUNDATION

(PIER AND BEAM)

GUTTERS AROUND FASCIA, TYPTO MATCH EXISTING

3 HEADER BRICK (STACKED)ADJACENT TO WINDOWS, TYPTO MATCH EXISTING

107'-4" AFF - SOFFIT (VIF)

PAINTED HARDIE BOARD FASCIA BOARD

98'-9", VIF LOWER LEVEL(SLAB ON GRADE)

100'-0" FINISHED FLOOR

COMPOSITE SHINGLES,TO MATCH EXISTING

PAINTED STEEL POST

PAINTED HARDIE BOARD SOFFIT AND VENTSPAINTED HARDIE TRIM BOARD

(PIER AND BEAM)

BRICK SOLDIER COURSE,TO MATCH EXISTING

BRICK SOLDIER COURSE, TYPTO MATCH EXISTING

RUNNING BOND BRICK , TYPTO MATCH EXISTING

ROWLOCK SILL , TYPTO MATCH EXISTING

EXPOSED FOUNDATIONPAINTED STEEL POST

COMPOSITE SHINGLES,TO MATCH EXISTING

01.29.16

EXTERIOR ELEVATIONS

A2.101

Scale: 1/4" = 1'-0"

EAST ELEVATION MM.DD.YY

MM.DD.YY

TITLESHEET

A0.00

XXX

XXX

XXX

ISSU

ED F

OR C

ONST

RUCT

ION

REVISIONS

ItemDateNo.

Project No.DateLast Revision

15014.00

6230

SAR

ATOG

A CI

RCLE

ADDI

TION

& R

EMOD

ELDA

LLAS

, TX

7521

4

SIDEBAR

COLLAB

ORATIVE, P

LLC

01.29.16

2201 PR

IMROSE

AVE / FOR

T WORT

H, TX 761

11 / 214.4

05.9613

/ sidebarcolla

b.com

THE REEDY GROUP4434 West Lovers LaneDallas, TX 75209Contact: Frank Reedy, [email protected]

02Scale: 1/4" = 1'-0"

NORTH ELEVATION04Scale: 1/4" = 1'-0"

SOUTH ELEVATION

03Scale: 1/4" = 1'-0"

WEST ELEVATION

Page 5: DALLAS, TX 75214 6230 SARATOGA CIRCLEstorage.cloversites.com/bluestonepartnersllc/documents/Strasner... · building code: 2012 international residential building code plumbing code

A

A

A

A

S

S

S

D

SSSSS

S

A

A

A

S

C

C C

C

A

A

A

A

A

S

S

S S

S

JK

S

A5

AA3

S

SS

AA

AA

F (2)

LL

LL

L L

SS

S

A4

A3

C

S

JJ

S

SS

H

S

JQ

S

S

S

S

42"

68"68"32" 32" 32"

40"

USB

G

USB

68"

68"

USB

USB

D

40"

A4

A4 A4

A4

A4

A2 A2

A2

A2

A2

A2

B

B

E E

E

8'-0" 8'-0"

9'-3"9'-3"

8'-0"

9'-0"

8'-0"

8'-0"

8'-0"

FAMILY ROOM102

MASTERBEDROOM

104

103

CORRIDOR101

BREAKFASTNOOK

100

MASTERCLOSET

107

MUDROOM108GARAGE

109

MASTERBATH

105

MECH110

KITCHENE103

LIVING ROOME102

CORRIDOR

8'-0"

TOILET106

UNDER CABINETLIGHTING

UNDER CABINETLIGHTING

UNDER CABINETLIGHTING

UNDER CABINETLIGHTING

EQ 8'-0" EQ

8'-0"

EQEQ

2'-0" 2'-0"

2'-0"

2'-0"

SLOPE DOWN

SLOPE DOWN

SLOPE DOWN

SLOPE DOWN

SLOPE DOWN

SLOPE DOWN

10'-10"

02

02

CL CL

CL

CL

EQEQ

EQ EQ

EQ EQ EQ EQ6"

CL

CL

CL

CROWN IN VAULTCROWN

EQ EQ

CL

CL

7'-0"

4'-4"

4'-4"

CL

CL

7'-0"

5'-0"

5'-0"

5'-0"

EQEQ

CL

PULL DOWN ATTICACCESS LADDER

01

04

05

03

LEGENDDESCRIPTIONSYMBOL

AREA NOT IN SCOPE, UNO

EXISTING PARTITION

NEW PARTITION

DOOR NUMBER

00/X-000 ELEVATION MARKER

EXISTING DOOR TO REMAIN

DESCRIPTIONSYMBOL

WINDOW MARKER

DUPLEX RECEPTACLE

TELE / DATA- WALL

TELEVISION - WALL

J JUNCTION BOX

DENOTES HEIGHT OF DEVICEAFF

DENOTES SWITCH

##"

SUSPENDED FIXTURE-LARGE

WALL SCONCE

--

RECESSED DOWNLIGHT

--

--

NEW DOOR

EXISTING PARTITION, TO BEREMOVED

EXISTING DOOR TO BEREMOVED

S

XX

XX

1. THE LOCATIONS OF ALL POWER AND DATA RECEPTACLES, LIGHTING CONTROLS ANDSWITCHES, ETC ARE SHOWN FOR LOCATION ONLY AND SHALL BE CONFIRMED WITH THEOWNER AND/OR SIDEBAR COLLABORATIVE IN THE FIELD PRIOR TO ROUGH-IN.

2. THE GENERAL CONTRACTOR IS TO COORDINATE ALL DEVICE LOCATIONS WITH MILLWORK,FURNITURE, EQUIPMENT, LIGHTING, ELECTRICAL DEVICES, DATA DEVICES, AND PARTITIONFRAMING TO ENSURE PROPER PLACEMENT. NOTIFY OWNER AND/OR SIDEBAR COLLABORATIVEOF ANY DISCREPANCIES IN FIELD PRIOR TO COMPLETION OF WORK.

3. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR VERIFICATION AND COORDINATION OF ALLDIMENSIONAL, POWER, AND MOUNTING CRITERIA OF ALL FURNITURE AND EQUIPMENT,WHETHER CONTRACTOR-PROVIDED OR OWNER-PROVIDED. THE OWNER IS RESPONSIBLE FORPROVIDING CUT SHEETS FOR ALL OWNER-PROVIDED EQUIPMENT TO THE CONTRACTOR.

4. MOUNT DEVICES ON DRYWALL PARTITIONS TO CENTERLINE BETWEEN DOOR OPENINGS AND/ORCORNER EDGES U.N.O. MOUNT DEVICES ON COLUMNS TO CENTERLINE BETWEEN TWO CORNEREDGES. U.N.O.

5. DIMENSIONS SHOWN ARE TO THE CENTERLINE OF OUTLET OR CLUSTER OF OUTLETS. GANGEDCOVER PLATES SHALL BE A ONE PIECE UNIT.

6. SWITCHES SHOWN ADJACENT TO EACH OTHER SHALL BE GANGED AND COVERED WITH ASINGLE COVER PLATE. NOTIFY SIDEBAR COLLABORATIVE OF ANY CONFLICTS PRIOR TOINSTALLATION.

7. THE LIGHTING LAYOUT AND TYPES SHALL MEET ALL ENERGY CODE REQUIREMENTS OF THEAUTHORITY HAVING JURISDICTION.

8. PROVIDE CUT SHEETS AND/OR PRODUCT SUBMITTALS FOR ALL LIGHT FIXTURES ANDFIRE/LIFE/SAFETY DEVICES PRIOR TO ORDERING, FABRICATION, AND INSTALLATIONS.

9. ALL OUTLETS, SWITCHES, AND COVER PLATES TO BE WHITE, DECORA.

10. SMOKE DETECTORS TO BE INSTALLED PER CODE. ALL NEW SMOKE DETECTORS TO BEHARDWIRED. CONTRACTOR TO PROVIDE DEVICE SUBMITTAL AND COORDINATE LOCATIONSWITH OWNER AND/OR SIDEBAR COLLABORATIVE.

11. ALL CEILINGS TO RECEIVE PAINTED GYP BD, UNLESS NOTED OTHERWISE.

12. COORDINATE WITH OWNER ANY POWER REQUIREMENTS AND LOCATIONS FOR AUDIO VISUAL,INTERNET, AND SECURITY SYSTEM.

13. COLOR TEMPERATURE FOR LIGHT FIXTURES TO MATCH EXISTING; COORDINATE WITH OWNERAND ARCHITECT.

CEILING/POWER NOTES

QUAD RECEPTACLE

-STRIP OR TRACK FIXTURE

GYP BD CEILING

01 PROVIDE 34" PLYWOOD DECK ON CEILING JOISTS FOR ATTIC STORAGE (16'X16') AND HVAC EQUIPMENT; PROVIDELIGHT WITH SWITCH IN ATTIC

02 APPLIED WOOD BEAMS, PAINTED. PRICE AS ALTERNATE STAINED WOOD BEAMS

KEY NOTES

03 WIRE MANAGEMENT FOR ALL AUDIO VISUAL EQUIPMENT, INCLUDING SPEAKERS, TO BE HIDDEN WITHINWALL;COORDINATE W/ OWNER AND AV VENDOR.

04 ADD LIGHT FIXTURE TO EXISTING SWITCH FOR LIVING ROOM GENERAL LIGHTING

05 CONSOLIDATE W/ EXISTING SWITCHES INTO SINGLE COVER PLATE

DENOTES USB COMBINATIONRECEPTACLE (DUAL OUTLETAND DUAL USB)

USB

01.29.16

CEILING AND POWER PLAN

A3.101

Scale: 1/4" = 1'-0"

REFLECTED CEILING PLAN MM.DD.YY

MM.DD.YY

TITLESHEET

A0.00

XXX

XXX

XXX

ISSU

ED F

OR C

ONST

RUCT

ION

REVISIONS

ItemDateNo.

Project No.DateLast Revision

15014.00

6230

SAR

ATOG

A CI

RCLE

ADDI

TION

& R

EMOD

ELDA

LLAS

, TX

7521

4

SIDEBAR

COLLAB

ORATIVE, P

LLC

01.29.16

2201 PR

IMROSE

AVE / FOR

T WORT

H, TX 761

11 / 214.4

05.9613

/ sidebarcolla

b.com

THE REEDY GROUP4434 West Lovers LaneDallas, TX 75209Contact: Frank Reedy, [email protected]

Page 6: DALLAS, TX 75214 6230 SARATOGA CIRCLEstorage.cloversites.com/bluestonepartnersllc/documents/Strasner... · building code: 2012 international residential building code plumbing code

OPEN

OPENREFRIGERATOR

01FILE NAME: A4.1.DWG

FAMILY ROOMSCALE: 3/8"=1'-0"

02FILE NAME: A4.1.DWG

FAMILY ROOMSCALE: 3/8"=1'-0"

05FILE NAME: A4.1.DWG

UTILITY ROOMSCALE: 3/8"=1'-0"

06FILE NAME: A4.1.DWG

UTILITY ROOMSCALE: 3/8"=1'-0"

04FILE NAME: A4.1.DWG

DESK/ CORRIDORSCALE: 3/8"=1'-0"

03FILE NAME: A4.1.DWG

BREAKFAST NOOKSCALE: 3/8"=1'-0"

WASHERDRYER

OPEN

OPEN

OPEN

OPEN

OPEN OPEN

OPEN

OPEN

OPEN

OPEN

OPEN

OPEN

CHALKBOARD PAINT

TACK BOARD

FABRIC WRAPPED HOMASOTE PANELS

07FILE NAME: A4.1.DWG

BAR/ CORRIDORSCALE: 3/8"=1'-0"

08FILE NAME: A4.1.DWG

BREAKFAST NOOKSCALE: 3/8"=1'-0"

PAINTED WOOD DESK ANDDRAWERS WITH WIREMANAGEMENT; COORDINATEWITH OWNER AND EQUIPMENT

CABINET FACES ANDHARDWARE TO MATCHEXISTING KITCHEN CABINETS;ADJUSTABLE SHELVING, TYP.

HANGING FILE DRAWER;LOCKABLE

10 1/2" 3'-4 1/2"*VERIFY W/EQUIP*

6 EQ 5'-3 1/2"*VERIFY W/EQUIP*

4"

HANGING ROD

PAINTED WOOD CABINETSWITH ADJUSTABLE SHELVING

TVBY OWNER

PAINTED WOOD TOPFLIP UP DOORS

WALL MOUNTED TV TO BE FLUSHWITH FRONT FACE OF MILLWORK

PAINTED WOOD CABINETS WITHADJUSTABLE PAINTED WOOD

SHELVING; COORDINATE SHELVINGHEIGHT AND DEPTH AND WITH OWNER

PARTIAL DEPTH SHELVES TO ALLOWSTORAGE SPACE FOR TALLER ITEMS

I.E. BROOMS AND STEAMER

SOLID SURFACE TOPWITH 4" SPLASH (SS-1)

TRASH/RECYCLE

FLEX DIMPER TRASH/RECYCLE REQUIREMENTS

WOOD VENEER POCKET DOOR;FINISH TBD

2'-7"

CROWN MOLDING TOMATCH EXISTING

CROWN MOLDING TOMATCH EXISTING

1'-6"

1'-9"

3'-9"

7'-0"

8'-0"

BASE TO MATCHEXISTING

PAINTED WOOD BENCH;COORDINATE DETACHABLECUSHIONS W/ OWNER AND

ARCHITECT116°

95°

FABRIC WRAPPEDPANELS; FABRIC TO BESELECTED BY OWNER

1'-6" 4 EQUAL

PAINTED WOODCABINETS; LOCKABLE

PAINTED WOOD CABINETSW/ ADJUSTABLE SHELVES

STAINED WOOD SHELF

STONE COUNTERTOP

WALL TILE(WT-3)

1'-6"

VIF

PAINTED GYP

CROWN MOLDING TOMATCH EXISTING

BASE TO MATCHEXISTING

PAINTED WOOD BENCH; COORDINATEDETACHABLE CUSHION OPTION W/

OWNER AND ARCHITECT

FABRIC WRAPPEDPANELS; FABRIC TO BESELECTED BY OWNER

PAINTED GYP

4'-0"

1'-6"

1'-9"

3'-9"

1'-0"

8'-0"

EQEQ

BASE TO MATCHEXISTING

3 EQ1 1/2"

EQ1 1/2"

EQ1 1/2"

EQ1 1/2"

3 EQ

2'-11

"1 1

/2"

4'-0" CLEAR 5'-0" 7'-0"VIF

5'-0"

4"3"

1 1/2"

1 1/2"

1'-7"

1'-2"

1'-0"

3"

UNDER CABINET LIGHTING

1 1/2"

3'-0"

PAINTED WOOD SHELVES WITHFIXED INTERMEDIATE SHELVING

OPEN

1'-3 1

/2"5"

5" 4"

1'-9" 1'-9" 2'-0"3'-0"

1 1/2"

2'-1"

3'-4"

3"8"

2'-3 1

/2"1 1

/2" 1'-3"1 1/2" 3'-9" 1'-3" 1 1/2"

1'-0" 4 EQ 1'-0"

UNDER CABINET LIGHTING

BASE TO MATCHEXISTING, TYP.

1'-8" 1'-8" 1'-8" 1'-8" 1 1/2"1 1/2"1 1/2"1 1/2"1 1/2"

1'-6"

1 1/2"

3'-4"

8"1 1

/2"1'-3"

1 1/2"

1 1/2"

4'-0" 4'-0" 4 EQ 1'-9"

BASE TO MATCHEXISTING, TYP.

PAINTED WOOD BENCH

PAINTED WOOD SHELVING, TYP.

3 COAT HOOKS IN EACH CUBBIE,TO BE SELECTED BY OWNER.

7'-2"

6"

1'-0 1

/2"2'-

7 1/2"

10 3/

4"10

3/4"

1 1/2" 1'-

0"

01.29.16

INTERIOR ELEVATIONS

A4.1MM.DD.YY

MM.DD.YY

TITLESHEET

A0.00

XXX

XXX

XXX

ISSU

ED F

OR C

ONST

RUCT

ION

REVISIONS

ItemDateNo.

Project No.DateLast Revision

15014.00

6230

SAR

ATOG

A CI

RCLE

ADDI

TION

& R

EMOD

ELDA

LLAS

, TX

7521

4

SIDEBAR

COLLAB

ORATIVE, P

LLC

01.29.16

2201 PR

IMROSE

AVE / FOR

T WORT

H, TX 761

11 / 214.4

05.9613

/ sidebarcolla

b.com

THE REEDY GROUP4434 West Lovers LaneDallas, TX 75209Contact: Frank Reedy, [email protected]

Page 7: DALLAS, TX 75214 6230 SARATOGA CIRCLEstorage.cloversites.com/bluestonepartnersllc/documents/Strasner... · building code: 2012 international residential building code plumbing code

01FILE NAME: A4.2.DWG

MASTER BATHSCALE: 3/8"=1'-0"

02FILE NAME: A4.2.DWG

MASTER BATHSCALE: 3/8"=1'-0"

BUILT-IN BATH SHELF

03FILE NAME: A4.2.DWG

MASTER BATHSCALE: 3/8"=1'-0"

OPEN

OPEN

04FILE NAME: A4.2.DWG

MASTER BATHSCALE: 3/8"=1'-0"

ROBE HOOKS TO BE SELECTED BY OWNER

WALL TILE(WT-1)

OPEN

OPEN

OPEN

OPEN8"8"

8"8"

OPEN

OPEN

OPEN

OPEN

OPEN

OPEN

OPEN

OPEN

OPEN

OPEN

OPEN

OPEN OPEN

05FILE NAME: A4.2.DWG

MASTER CLOSET: HISSCALE: 3/8"=1'-0"

06FILE NAME: A4.2.DWG

MASTER CLOSETSCALE: 3/8"=1'-0"

07FILE NAME: A4.2.DWG

MASTER CLOSET: HERSSCALE: 3/8"=1'-0"

08FILE NAME: A4.2.DWG

MASTER CLOSET: HERSSCALE: 3/8"=1'-0"

OPEN OPEN

OPEN BEYOND

09FILE NAME: A4.2.DWG

MASTER CLOSETSCALE: 3/8"=1'-0"

ACCESSORY HOOKS

FRAMED MIRROR

6'-4"

FULL-HEIGHTMIRROR

6"4'-

0"2'-

9"

8'-0"

OPEN

BATHTUB 2'-2"

VERIF

Y W/ T

UB

WALL TILE(WT-X)

BATH TUB

10FILE NAME: A4.2.DWG

LINEN CLOSETSCALE: 3/8"=1'-0"

STONE COUNTER TOP, TYP.WOOD VENEER DRAWERS

MOSAIC TILE BACKSPLASH, WT-2

WOOD VENEER MILLWORK

PAINTED WOOD CABINETS

1'-2"

FINISH EDGE WITH STAINLESSSTEEL SCHLUTER

4"

2'-0"

CL

OPEN

WALL TILE(WT-1)

WALL TILE(WT-1)

BUILT-INSHOWER SHELF, WT-2

EQ 5'-0" EQ

BUILT-IN SHOWERBENCH, WT-1

1'-2"

6"1'-

2"11

1/2"

1'-6"

ALL GLASS SHOWERPARTITION WITH SUPPORT

CHANNELS RECESSED INTOFLOOR AND WALL

7'-0"

4"

9"

BUILT-IN BATH SHELF 10" 1'-9"VERIFY W/ SINK

1'-7" 10"1'-9"VERIFY W/ SINK

2'-4 1/2"VIF

1'-0"

ALIGN

ALIGN6"

6"6"

1'-0"

4"

3"

2'-7"

4"1'-

0"6"

6"3"

MIRROR WITH FINISHED SS EDGESAT TOP AND BOTTOM 2'-0 1/2"

VIF8" 8"

RECESSED MIRROR

STONE COUNTER TOP, TYP.

PAINTED WOOD CABINETS AND DRAWERS

2 EQ

4'-0"

1'-6"

1'-6"3'-5"1'-6"

3 EQ

3'-5 1

/2"

1'-1"

1 1/2"

1 1/2"

3'-10

1/2"

2'-4"

3 EQ

1'-0"

2 EQ

1'-6"

PAINTED WOODDRAWERS, TYP.

PAINTED WOOD

PAINTED WOODBENCH

7'-0"

8"3'-

0"

1'-8 3

/4"1'-

8 3/4"

8"8"

8"8"

7'-0"

8"3'-

0"

3'-0" 3'-6 1/4"VIF

3'-6 1/4"VIF

3'-6"

1'-1"

3'-5" 2'-9" 7'-3" 2'-6"

OPEN

3'-6"

OPEN

2'-2"

7'-0"

5'-3"

4'-0"

1'-1"

7'-0"

SAFE

01.29.16

INTERIOR ELEVATIONS

A4.2MM.DD.YY

MM.DD.YY

TITLESHEET

A0.00

XXX

XXX

XXX

ISSU

ED F

OR C

ONST

RUCT

ION

REVISIONS

ItemDateNo.

Project No.DateLast Revision

15014.00

6230

SAR

ATOG

A CI

RCLE

ADDI

TION

& R

EMOD

ELDA

LLAS

, TX

7521

4

SIDEBAR

COLLAB

ORATIVE, P

LLC

01.29.16

2201 PR

IMROSE

AVE / FOR

T WORT

H, TX 761

11 / 214.4

05.9613

/ sidebarcolla

b.com

THE REEDY GROUP4434 West Lovers LaneDallas, TX 75209Contact: Frank Reedy, [email protected]

Page 8: DALLAS, TX 75214 6230 SARATOGA CIRCLEstorage.cloversites.com/bluestonepartnersllc/documents/Strasner... · building code: 2012 international residential building code plumbing code

OBSCURE GLASS

TYPE A-FLUSH SOLID CORE WOOD VENEER DOOR

REFER TO SCHEDULE

6'-8"

TYPE F-STILE & RAIL OVERHEAD SECTIONAL

GARAGE DOOR

18'-0"

8'-0"

2'-0"

2'-0"

2'-0"

2'-0"

6" 6"

4'-0"

2'-8"

3'-0"

TYPE B-FLUSH SOLID CORE WOOD VENEER

POCKET DOOR

6'-8"

REFER TO SCHEDULE

TYPE C-PAIR OF SOLID CORE WOOD DOORS WITH GLASS,

PAINTED

6'-10

"

REFER TO SCHEDULE

TYPE E-EXTERIOR WOOD DOOR, PAINTED

6'-10

"

3'-0"

5'-4"

3'-0"

VIF4'-

0"

2'-0"

1'-6"

1'-6"

3'-0"

5'-6"

5'-6"

3'-0"

4'-0"

7'-0"

4'-0"

4'-8"

2'-4"

FINISH FLOOR

8'-8"

TYPE D-EXTERIOR WOOD DOOR, PAINTED

6'-10

"

3'-0"

SINGLE HUNG

FIXED FIXED

FIXED

CASEMENT

EQEQ

SINGLE HUNGSINGLE HUNG SINGLE HUNG

**PRICE SHUTTERS TO MATCH EXISTING;COORDINATE W/OWNER**

**PRICE SHUTTERS TO MATCH EXISTING;COORDINATE W/OWNER**

*CRANK OPERABLE*

COMPOSITION ASPHALT SHINGLES TO MATCH EXISTING

34" PLYWOOD DECKING

RAFTER

BRICK MASONRY TO MATCH EXISTING

AIR GAP , KEEP CAVITY CLEAR

CONTINUOUS MOISTURE BARRIER

12" EXTERIOR SHEATHING

SEALANT

SOFFIT BOARD (VENTS WHERE REQUIRED)

FASCIA BOARD, MATCH EXISTING

CONTINUOUS MOISTURE BARRIER

12" PAINTED GYP BD.

R-38 BATT ROOF INSULATION

GYP BD CEILING

1X3 WOOD TRIM

3X3 WOOD TRIM

R-20 SPRAY FOAMINSULATION

12" GYP. BOARD

12" GYP. BOARD

SILL PLATE BELOW

2X4 STUDS STAGGERED

2X4 STUDS

1/2"

SOUND ATTENUATIONBATTS

01.29.16

SCHEDULESDOOR/ WINDOW TYPES &

A5.101

Scale: 3/8" = 1'-0"

DOOR & WINDOW TYPES

ABCD

ALL GLAZING TO BE LOW "E" AND MEET IECC SPECS ALL GLASS TO BE TEMPERED WITH A MAXIMUM SHGC OF 0.30

WINDOW NOTES: - WINDOWS TO BE METAL CLAD WOOD, MARVIN WINDOWS OR EQUAL WINDOW MANUFACTURER SIZES VARY. VERIFY ALL WINDOW SIZES, TYPES, AND ROUGH OPENING DIMENSIONS PRIOR TO FRAMING.

E

MM.DD.YY

MM.DD.YY

TITLESHEET

A0.00

XXX

XXX

XXX

ISSU

ED F

OR C

ONST

RUCT

ION

REVISIONS

ItemDateNo.

Project No.DateLast Revision

15014.00

6230

SAR

ATOG

A CI

RCLE

ADDI

TION

& R

EMOD

ELDA

LLAS

, TX

7521

4

SIDEBAR

COLLAB

ORATIVE, P

LLC

01.29.16

2201 PR

IMROSE

AVE / FOR

T WORT

H, TX 761

11 / 214.4

05.9613

/ sidebarcolla

b.com

THE REEDY GROUP4434 West Lovers LaneDallas, TX 75209Contact: Frank Reedy, [email protected]

F

101

102

MARK SIZE MATERIALLOCATION

SC WOOD

105

DOOR SCHEDULE

NAMEITEM COLOR NOTES/ALLOWANCES:MANUFACTURERMODEL#

BATH (TUB-1)

SC WOOD

NOTES- DOOR HARDWARE TO BE SELECTED BY OWNER. PRICE SCHLAGE LOCKS, CYLINDERS, AND LEVERS. (FINISH TO MATCH EXISTING)

NOTES- FAUCETS TO BE BRUSHED CHROME SELECTED BY OWNER.

110

CORRIDOR 4'-0" X 6'-8"

NOTES

STAINED

FAMILY ROOM

MASTER BEDROOM

MASTER BATHROOM

PAIR OF 3'-0" X 6'-10"

TOILET

SC WOOD

SC WOOD3'-0" X 6'-8"

SC WOODMECHANICAL 3'-0" X 6'-8"

- SHOWER DOOR PULLS TO BE SELECTED BY OWNER.

TYPE

B

C

A

B

B

A

A

B

A

F

E

FLOOR TILE 1 (FT-1)

SIZEITEM COLOR NOTES:MANUFACTURERMODEL#

SOLID S. (SS-1)

RECESSED CAN

PLUMBING SCHEDULE

TOILET (WC-1)

SINK (LAV-1) WHITE

WHITE

KOHLER MASTER BATH

MASTER BATH

KOHLER

K-2214

NAMEITEM COLOR NOTES/ALLOWANCES:MODEL#

LIGHT FIXTURE SCHEDULE

WHITE

WHITE

FIXTURE A

FIXTURE A2

FIXTURE B

FIXTURE C

FIXTURE G

FIXTURE H

FIXTURE E

FIXTURE L

RECESSED CAN

WALL SCONCE TO BE SELECTED BY OWNER

4' STRIP FLOURESCENT

WHITE

UNDERCABINET

WET AREA

FINISH SCHEDULE

FLOOR TILE 2 (FT-2)

FLOOR TILE 3 (FT-3)

WOOD FLR (WD-1)

WALL TILE 1 (WT-1)

WALL TILE 2 (WT-2)

WALL TILE 3 (WT-3)

SEALED CONCRETE (SC-1)

- MILLWORK HARDWARE TO BE SELECTED BY OWNER

WOOD (WD-2)

SC WOOD

2'-8" X 6'-8"

SC WOOD POCKET

2'-8" X 6'-8"

2'-8" X 6'-8"

SC WOOD

2'-8" X 6'-8"

POCKET

POCKET

3-0" X 6'-10" SC WOOD

D

LADENA

WHITE K-3609 (1.28 GPF)CIMARRON KOHLER

- LAVATORY, BATHTUB, AND SHOWER FAUCETS TO BE SELECTED BY OWNER.- KOHLER OR EQUAL - ALL FAUCETS TO BE 2.0 GALLON PER MINUTE OR LESS

MASTER BATHK-6369SUNSTRUCK

PORCELAIN

PORCELAIN

PORCELAIN

SOLID PLANK

LOCATION

UTILITY/MUDROOM

MASTER BATH

STAIR TREADS

MASTER VANITY

BAR / CORRIDOR 101

BAR/CORRIDOR 101

MASTER BATH (FIELD)

SHOWER FLOOR

BASE 4" PAINTED WOOD THROUGHOUT

EXTERIOR BRONZE

8' STRIP FLOURESCENT

SURFACE MOUNT

***ALL FIXTURES TO BE LED UNLESS NOTED OTHERWISE***

STILE/RAIL WOOD, GLASS PAINTED

104

2'-8" X 6'-8"

106

MASTER CLOSET107

MUDROOM108

109 GARAGE

PAINTED

111

112

GARAGE 18'-0" X 8'-0" OVERHEAD SECTIONAL, PAINTEDSTILE/RAIL WOOD, GLASS

PAINTED

PAINTED

PAINTED

EXTERIOR GARAGE

113

PAINTED

PAINTEDEXTERIOR MUDROOM 3'-0" X 6'-10" STILE/RAIL WOOD, GLASS

12 X 24

18 X 18

MOSAIC MASTER BATH

STAINED HARDWOODS TO MATCH EXISTING

ROUNDED NOSINGTO MATCH EXISTING

GARAGE

UTILITY/MUDROOM

STONE (ST-1)

STONE (ST-2)

SLAB

SLAB

TO BE SELECTED

TO BE SELECTED

MASTER BATH (ACCENT) TO BE SELECTED

TO BE SELECTED

MOSAIC

TO BE SELECTED

FIXTURE A3 RECESSED CAN WHITE DIRECTIONAL ADJUSTMENT

FIXTURE A4 RECESSED CAN WHITE SLOPED CEILING, DIMMABLE

SURFACE MOUNT

SURFACE MOUNT

FIXTURE Q PENDANT

VANITY SCONCE TO BE SELECTED BY OWNER WET AREA

TO BE SELECTED BY OWNER

RECESSED MR-16

FIXTURE F STRIP LIGHTS VANITY, WET AREA

FIXTURE J PENDANT WET AREATO BE SELECTED BY OWNER

FIXTURE A5 RECESSED CAN WHITE TO MATCH EXISTING

02Scale: 1 1/2" = 1'-0"

SECTION DETAIL

114 LIVING ROOM PAIR OF 3'-0" X 6'-10" (VIF) CSTILE/RAIL WOOD, GLASS PAINTED

03Scale: 3" = 1'-0"

ACOUSTICAL PARTITION PLAN DETAIL