Daikin Altherma Selection Software
A Guide To using The Selection Software
-
7/27/2019 Daikin Altherma-Using Selection Software Program_UKEAUTSSP 0510_tcm219-168626
2/18
www.altherma.co.uk
Using The Selection Software Program
Page 2
Select a location as this will
automatically insert weather conditions,
-
7/27/2019 Daikin Altherma-Using Selection Software Program_UKEAUTSSP 0510_tcm219-168626
3/18
www.altherma.co.uk Page 3
Select preferences
Select what units you prefer
-
7/27/2019 Daikin Altherma-Using Selection Software Program_UKEAUTSSP 0510_tcm219-168626
4/18
www.altherma.co.uk Page 4
Equipment prices (can be omitted)
Currency used
-
7/27/2019 Daikin Altherma-Using Selection Software Program_UKEAUTSSP 0510_tcm219-168626
5/18
www.altherma.co.uk Page 5
You will need to input Heat pump electricity cost and electric heating
cost. You need to input a high and low electricity costing i.e. economy7, for this you can add and remove the stars depending when your
price changes activate. If your not on economy 7 then you will have to
average your KW/H cost into one figure and add this to both fields
-
7/27/2019 Daikin Altherma-Using Selection Software Program_UKEAUTSSP 0510_tcm219-168626
6/18
www.altherma.co.uk Page 6
Input fields when zero heating will be
required due to ambient conditions and
minimum heat pump coverage
-
7/27/2019 Daikin Altherma-Using Selection Software Program_UKEAUTSSP 0510_tcm219-168626
7/18www.altherma.co.uk Page 7
For a price comparison to gas thenthese fields will need to be
accurately inputted
-
7/27/2019 Daikin Altherma-Using Selection Software Program_UKEAUTSSP 0510_tcm219-168626
8/18www.altherma.co.uk Page 8
For a fuel comparison to Daikin
Altherma and gas then these fields
will need to be accurately inputted
-
7/27/2019 Daikin Altherma-Using Selection Software Program_UKEAUTSSP 0510_tcm219-168626
9/18www.altherma.co.uk Page 9
System drawing settings
-
7/27/2019 Daikin Altherma-Using Selection Software Program_UKEAUTSSP 0510_tcm219-168626
10/18www.altherma.co.uk Page 10
If no unit price has been
entered then you will see this
box click on yes
-
7/27/2019 Daikin Altherma-Using Selection Software Program_UKEAUTSSP 0510_tcm219-168626
11/18www.altherma.co.uk Page 11
Left click of the mouse to add and
remove operating monthsRight click of the mouse to add and
remove operating months
Results are now activated
-
7/27/2019 Daikin Altherma-Using Selection Software Program_UKEAUTSSP 0510_tcm219-168626
12/18www.altherma.co.uk Page 12
Choose which system you require
Right click on the mouse
on the dotted outline to
select the specific
equipment required
Once all selections have been done a list of all
available systems will appear
-
7/27/2019 Daikin Altherma-Using Selection Software Program_UKEAUTSSP 0510_tcm219-168626
13/18www.altherma.co.uk Page 13
You will require the Equilibrium point to
insert in the commissioning stage
The solution can be refined
by changing the required
temperatures
-
7/27/2019 Daikin Altherma-Using Selection Software Program_UKEAUTSSP 0510_tcm219-168626
14/18
www.altherma.co.uk Page 14
You will require the Equilibrium point to
insert in the commissioning stage
-
7/27/2019 Daikin Altherma-Using Selection Software Program_UKEAUTSSP 0510_tcm219-168626
15/18
www.altherma.co.uk Page 15
Costing graphs then can be obtained
-
7/27/2019 Daikin Altherma-Using Selection Software Program_UKEAUTSSP 0510_tcm219-168626
16/18
www.altherma.co.uk Page 16
Make a field settings report
-
7/27/2019 Daikin Altherma-Using Selection Software Program_UKEAUTSSP 0510_tcm219-168626
17/18
www.altherma.co.uk Page 17
1st
code
2nd
code
Setting name Date
(*)
Value
(*)
Date
(*)
Value
(*)
Default
value
Range Step Unit
0 User permission level
00 User permission level 3 2-3 1 -
1 Weather dependent set point
00 Low ambient temperature (Lo_A) -4 -10 -20-5 1 C
01 High ambient temperature (Hi_A) 16 15 10-20 1 C
02 Set point at low ambient temperature
(Lo_TI)
35 40 25-55 1 C
03 Set point at high ambient temperature
(Hi_TI)
30 25 25-55 1 C
2 Disinfection function
00 Operation interval Fri Mon-Sun,
All
- -
01 Status 1 (ON) 1 (ON) 0/1 - -
02 Start time 23:00 0:00-23:00 1:00 hour
03 Set point 70 40-80 5 C
04 Interval 10 5-60 5 min
3 Auto restart
00 Status 0 (ON) 0 (ON) 0/1 - -
4 Backup heater operation
00 Status 1 (ON) 1 (ON) 0/1 - -
01 Priority 0 (OFF) 0 (OFF) 0/1 - -
-
7/27/2019 Daikin Altherma-Using Selection Software Program_UKEAUTSSP 0510_tcm219-168626
18/18
www.altherma.co.uk Page 18
1st
code
2nd
code
Setting name Date
(*)
Value
(*)
Date
(*)
Value
(*)
Default
value
Range Step Unit
5 Equilibrium temperature and space heating
priority temperature
00 Equilibrium temperature status 1 (ON) 1 (ON) 0/1 - -
01 Equilibrium temperature -4 0 -15-20 1 C
02 Space heating priority status 1 (ON) 0 (OFF) 0/1 - -
03 Space heating priority temperatures -2 0 -15-20 1 C
04 Set point correction for sanitary water temperature 10 10 0-20 1 C
6 DT for sanitary water heating
00 Start 5 5 1-20 1 C
01 Stop 0 0 0-10 1 C
7 Sanitary water step length
00 Sanitary water step length 3 3 2-4 1 C
8 Sanitary water heating mode timer
00 Minimum running time 5 5 0-20 1 min
01 Maximum running time 45 30 20-95 5 min
02 Anti-recycling time 1.5 3 0-10 0.5 hour
03 Booster heating delay time 60 20 20-95 5 min
9 Cooling and heating set point ranges
00 Heating set point upper limit 35 55 37-55 1 C
01 Heating set point lower limit 30 25 25-37 1 C
02 Cooling set point upper limit - - - - 20 18-20 1 C
03 Cooling set point lower limit - - - - 5 5-18 1 C