CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

47
CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06

Transcript of CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

Page 1: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

CVFD Training – SCBA

SFFMA Training Objectives:27-01.01 – 27-01.06

Page 2: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.2

Objectives (1 of 2)

• List two conditions requiring respiratory protection.• List and explain the effects of oxygen deficiency and toxic

gases on the human body.• List one legal requirement for use of SCBA.• List two types of SCBA.• List four components of the SCBA used by the authority

having jurisdiction.

Page 3: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.3

Objectives (2 of 2)

• Demonstrate two different SCBA donning procedures.

• Demonstrate routine inspection of SCBA.• Demonstrate after-use maintenance and

servicing.• Demonstrate the servicing of an SCBA cylinder

with the air-filling system.

Page 4: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.4

Introduction (1 of 3)

• SCBA an important item of PPE.• SCBA allows firefighters to work in oxygen

deficient atmospheres.• Human body very vulnerable to oxygen deficient

atmosphere.• Respiratory protection policy must exist.• SCBA required in an IDLH area.

Click Here to View Video: SCBA Functions

Page 5: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.5

Introduction (2 of 3)

• Many changes in SCBAs since the 1970s– Decrease in weight– Must be positive pressure– Improved design– SCBA maintenance programs– PASS devices– Better training programs– Increased regulations

Page 6: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.6

Introduction (3 of 3)

• Improvements– Technology– Regulations– Mandates

• SCBA improvements are only as effective as the training and proficiency firefighters develop in using SCBA.

Page 7: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.7

Conditions Requiring Respiratory Protection

• Oxygen deficiency• High temperatures• Smoke• Unburned products

of combustion• Toxic environment

Page 8: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.8

Oxygen-Deficient Environments

• Humans and fire both require oxygen to survive.• Oxygen deficiency is detrimental to the human body.

Click Here to View Video: Proper Use of SCBA/ Effects of Smoke and Fire

Click Here to View Video: SCBA Standards, Types and Limitations

Page 9: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.9

Elevated Temperatures and Smoke

• Inhalation of heated gases can cause fluid to build up in the lungs and create long-term, irreversible damage.

• Combustion by-products are very irritating to the body.

• High temperatures can also cause severe burns to the respiratory system.

Page 10: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.10

PPE for Oxygen-Deficient Environment

Page 11: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.11

Effects of Toxic Gases and Environments (1 of 2)

• Toxic gases are produced by combustion.– These gases affect various body systems.

• Hazardous materials can increase the risk to firefighters.

• CO is one of the most lethal gases produced by fire.– CO attaches to blood 218 times easier than O2.

Page 12: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.12

Effects of Toxic Gases and Environments (2 of 2)

• CO prevents distribution of O2 in the body, causing hypoxia.

• Without SCBA, a firefighter will not survive.

• Repeated exposure to toxins has long-term effects.

Page 13: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.13

Legal Requirements for SCBA

• OSHA - Respiratory Protection Standard Title 29 CFR 1910.134

• 29 CFR 1910.134 standard for all entries into IDLH atmospheres

• NFPA standards (1500, 1404, 1981)• NIOSH 42 CFR Part 84

Page 14: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.14

Organizations Concerned with SCBA Design and Use

ORGANIZATION STANDARD APPLICATION

National Institute for Occupational Safety & Health (NIOSH)

42 CFR Part 84 Requirements for design, testing, certifying SCBA

Occupational Safety & Health Administration (OSHA)

29 CFR 1910.134 Respiratory protection programs for SCBA use

Occupational Safety & Health Administration

29 CFR 1910.156 Fire Brigade Standard, references 1910.134

National Fire Protection Association

NFPA 1404 Standard for Fire Department SCBA Program

National Fire Protection Association

NFPA 1500 Standard on Fire Department Occupational Safety & Health Program

National Fire Protection Association

NFPA 1981 Standard on Open-Circuit SCBA for the Fire Service

Organizations Concerned with SCBA Design and Use

Page 15: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.15

Limitations of SCBA (1 of 2)

• SCBA design and size– Increases weight and girth– Decreases mobility– Requires good physical conditioning– Must be aware of how long air will last– Limits visibility– Voice muffled and hard to understand

Page 16: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.16

Limitations of SCBA (2 of 2)

• Limitations of SCBA user– Factors such as facial hair or weight loss can alter

mask effectiveness.– Lack of confidence can lead to anxiety.– Training/experience will improve confidence and

ability.– Increased physical stress causes anxiety.– Emotional state may affect respiratory rate and air

consumption.

Page 17: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.17

Constant Training Is Essential

Click Here to View Video: SCBA in Emergency Situations

Page 18: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.18

Physically Demanding Tasks

Page 19: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.19

Types of SCBA

• Two types of SCBA in use– Open-circuit SCBA– Closed-circuit SCBA

• Both built according to NIOSH and NFPA standards

Page 20: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.20

Open-Circuit SCBA (1 of 2)

Page 21: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.21

Open-Circuit SCBA (2 of 2)

• SCBA has four assembly components.– Backpack and harness– Cylinder– Regulator– Face piece assembly

Page 22: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.22

SCBA Harness Assembly

Page 23: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.23

Open-Circuit SCBA — Cylinders (1 of 2)

• SCBA cylinders vary in material and type.

• USDOT regulates compressed gas cylinders.

• Quality of the compressed breathing gas has a direct effect on the performance of the SCBA.

Page 24: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.24

Open-Circuit SCBA — Cylinders (2 of 2)

RATED DURATION (MINUTES)

MATERIAL CYLINDER PRESSURE (PSI)

CAPACITY COMPRESSED AIR (FT3)

30 Aluminum or Composite 2,216 44

30 Aluminum or Composite 4,500 44

45 Carbon Fiber 3,000 65

45 Aluminum or Composite 2,216 65

45 Aluminum or Composite 4,500 65

60 Aluminum or Composite 4,500 88

SCBA Air Cylinder Capacities

Page 25: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.25

SCBA Regulator (1 of 2)

• Regulator is attached to the face piece or waist strap.

• Regulator has a pressure gauge.

• Regulator is activated by user’s breathing action.

Page 26: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.26

SCBA Regulator (2 of 2)

• The regulator maintains constant positive pressure airflow to the face piece.

• Units have low air supply warning alarm.

• NFPA 1981 requires two types of alarms.

Page 27: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.27

SCBA Face Pieces

• Annual face piece fit test is required.

• Exhalation valve keeps toxic gases out.

Page 28: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.28

Closed-Circuit SCBA

• Not used for regular firefighting operations• Commonly used for hazmat operations and

below-grade rescues• Contains cylinder, filter system, regulator,

and valves

Page 29: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.29

Open-Circuit Supplied Air Respirator (SAR)

• Air supply cylinder is remote from user.

• It provides user with long- duration air supply.

• It is used for hazmat operations and confined space rescues.

Page 30: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.30

Donning and Doffing SCBA (1 of 2)

• Perform safety check first.• Use one of two methods.

– Over the head method– Coat method

• SCBA is also mounted in seats.

• Never stand to don while apparatus is moving.

• After securing SCBA, don face piece.

Click Here to View Video: SCBA Testing and Service/ Donning SCBA

Page 31: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.31

Donning and Doffing SCBA (2 of 2)

• The proper donning of a face piece is essential.

• After exiting hazardous area, remove SCBA. Remove face piece while waiting for assignment.

• Local protocol may require rehab after assignment.

Page 32: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.32

Over the Head Method

Page 33: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.33

Coat Method

Page 34: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.34

Seat-Mounted SCBA

Page 35: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.35

SCBA Operation and Emergency Procedures

• Firefighters must be proficient in:– Safe use of SCBA– Donning and doffing procedures– Individual limitations– Limitations of SCBA

Page 36: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.36

Safe Use of SCBA (1 of 2)

• Firefighters must be physically fit for respirator use.

• Accountability system should be in place.• Must work in teams of two at a minimum.• OSHA “two in/two out” regulation.• PASS device must be activated.

Page 37: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.37

Safe Use of SCBA (2 of 2)

• SCBA operations should include rehab time.• Stay hydrated during rehab.• Air consumption will vary for all.• Never remove the face piece in a

contaminated environment.• Low air alarm on one team member means

the whole team exits.

Page 38: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.38

PASS Devices

Page 39: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.39

Operating in a Hostile Environment (1 of 2)

• Always check in/out with accountability officer.

• Always remain low.• Check the environment.• Never remove a face piece.• Be aware of your location at all times.

Page 40: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.40

Operating in a Hostile Environment (2 of 2)

• Ventilate as you advance.

• Check outside openings.

• Maintain contact with team members.

• Never enter a hostile environment alone.

Page 41: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.41

Restricted Openings

• Never remove face piece!• Loosen straps and rotate SCBA under arm.• Remove harness and hold SCBA as a last

resort.• Do not lose contact with SCBA.• Maintain control of unit.• Practice procedures regularly.

Page 42: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.42

SCBA Use in Restricted Openings

Page 43: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.43

Emergency Procedures with SCBA

• Remain calm.• Immediately exit hazardous area.• Activate PASS device.• Announce your emergency over the radio.• If regulator or face piece fails, use bypass

valve.• Buddy breathing is only a last resort.

Page 44: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.44

Inspection and Maintenance of SCBA

• Have SCBA ready to go at all times.• Routinely inspect SCBA.

– Remove unit and check it after each use.– Monthly operational check should be done.

• Service less than full cylinder.

Page 45: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.45

Servicing SCBA Cylinders

• Test and certify air source.• Cylinders must have current hydrostatic test

date.• Fill stations must have fragmentation

containment devices.• Always follow manufacturer’s

recommendations.• Remember, fill rates will vary.

Page 46: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.46

Fragmentation Containment Device

Page 47: CVFD Training – SCBA SFFMA Training Objectives: 27-01.01 – 27-01.06.

7.47

Summary

• SCBA is one of the most important PPE items.• Both SCBA and the user have limitations.• Firefighters must be familiar and comfortable with use of

SCBA.• Firefighters need to be proficient in the proper and rapid

donning of SCBA• Routine inspections and maintenance are important.