Assignment 7 sewer. Side-view: Additional information: - equivalent roughness k-concrete = 1,5 mm, k-PVC = 1 mm - width weir = 2 m Preparation Calculate for each pipe: A, R (submerged) , C (rough boundary) and bed slope Question 1 (Only wastewater, no precipitation) a)In this situation the PVC250 pipe is half filled with waste water. Calculate the discharge and velocitiy. b)Check if the flow is turbulent Question 2 (Only wastewater, no precipitation) The supply of waste water on P3 and P2 is 10 l/s (both manholes). The pump capacity is 20 l/s. Calculate the water depth in pipe P2-P3 . Also calculate the velocity and hydraulic radius. Question 3 (Rain, precipitation) 3,75 ha paved area is connected to P2, 1,1 ha paved area is connected to P3. The rainfall intensity is 60 l/s.ha. a) Calculate the discharge rainwater which will flow from the paved area into the sewer? GL (ground level) +6.00 m 50 m Ø300 PVC Ø500 Ø250 PVC Pump P4 P3 P2 P1 weir IL +4,00 m IL +3,90 m IL +3,73 m IL (invert level +3,53 m) Rainfall & Waste Rainfall & Waste +5,5 m

description

 

Transcript of Cu06997 assignment 7 2013_new

Page 1: Cu06997 assignment 7 2013_new

Assignment 7 sewer.Side-view:

Additional information:- equivalent roughness k-concrete = 1,5 mm, k-PVC = 1 mm- width weir = 2 m

PreparationCalculate for each pipe: A, R (submerged) , C (rough boundary) and bed slope

Question 1 (Only wastewater, no precipitation)a)In this situation the PVC250 pipe is half filled with waste water. Calculate the discharge and velocitiy.b)Check if the flow is turbulent

Question 2 (Only wastewater, no precipitation)

The supply of waste water on P3 and P2 is 10 l/s (both manholes). The pump capacity is 20 l/s. Calculate the water depth in pipe P2-P3 . Also calculate the velocity and hydraulic radius.

Question 3 (Rain, precipitation)3,75 ha paved area is connected to P2, 1,1 ha paved area is connected to P3. The rainfall intensity is 60 l/s.ha.a) Calculate the discharge rainwater which will flow from the paved area into the sewer?

The figures show that the amount of rainwater in the sewer is much more than the amount of waste water. For the next questions we will neglect Waste water and the pump capacity.

b)Indicate the direction of the flow with rainfall. Calculate the discharge for each pipe.c)Calculate the specific height (H) at the weir (c=1,8)d)Calculate the head loss for branches P4-P3, P3-P2 and P2-P1. Also calculate the velocity head and velocity for each branch. Use Chezy’s formula.e)Calculate for each manhole the energy level and water levelf)Check if the flow is turbulent

Henk Massink, 5 april 2013

GL (ground level) +6.00 m

50 m

Ø300 PVC

Ø500 concrete

Ø250 PVC

Pump

P4 P3 P2

P1 weir

IL +4,00 mIL +3,90 m

IL +3,73 m

IL (invert level +3,53 m)

Rainfall &Waste water

Rainfall &Waste water

+5,5 m