IntroductionThis document describes the process o updating the frmware on
the Crucial m4 SSD using our Windows update utility. The utility
is a single executable fle that contains all the code necessary to
perorm the upgrade. The creation o a separate bootable device
is not necessary.
This program is to be used or updating the Firmware rom
Revisions 0001, 0002, 0009, 0309, or 000F to Revision 010G.
PLEASE NOTE: This frmware update is not applicable to any
Micron SSD which was purchased separately or as original
equipment in a computer system. Any frmware updates or
such drives, i necessary, will be made available by the computer
manuacturer or at www.micron.com. This frmware update is
not applicable to any Micron RealSSD C300 drive. It should not
be used with any Micron RealSSD C400 Sel Encrypting Drive
(SED). This update is or 2.5 m4 drives only and should not be
used to update mSATA m4 drives.
WARNING: As with all irmware updates, it is strongly
recommended that you backup or make copies o all important
fles beore perorming this update. This frmware update process
is done entirely at your own risk. I perormed correctly, there
will be no loss o system or user data on the drive. However, i
the frmware process is interrupted or any reason, your solid-
state drive may not unction properly. I this update is done on
a notebook computer, it is strongly recommended that power
be supplied by the AC power adapter.
General Instructions
Complete the ollowing steps beore starting the frmware
update process:
1. Backup the Solid-State Drive
It is highly recommended that ull system backup be completed
beore starting this irmware upgrade procedure. I the
upgrade is interrupted (by a power loss or hardware ailure
o some sort), it is possible that the solid-state drive may not
unction properly.
2. Use AC Power
Ensure your mobile PC or desktop PC is plugged in to AC
power during the update process. It is not recommended to
use only battery power during the upgrade. Do not remove
power at any time during the frmware update process as this
could produce incomplete results and may render your solid-state drive unusable.
3. Disable/Remove Drive Passwords
Password protection, such as OS drive encryption or BIOS-
level passwords can block frmware updates. Drive encryption
can be disabled in the OS or sotware tool you use or
encryption. To disable a BIOS password, you may need to edit
your computers BIOS settings. Please see your computers
owners manual or details on editing these settings. Enter the
BIOS (typically by hitting the Delete, F2 or F12 key during
start-up screen) and disable any passwords that you may have
set on the SSD.
4. Update Microsot .NET Framework
In order to be compatible with both Windows 7 and Windows
8, this frmware update tool is built under Microsot .NET
Framework 4. Some Windows 7 users may need to update
their .NET Framework version in order to enable this tool. I the
ollowing error message is noticed when running the frmware
updater, please use the Windows Update utility to update
.NET Framework.
SSD Firmware Update Utility GuideCrucial m4 2.5 SSD Firmware Revision 000F Firmware Update Guide or Windows 7 + Windows 8(Update rom Rev 0001, 0002, 0009, 0309, 000F to Rev 010G)
-
8/22/2019 CrucialFirmware m42!5!010G WindowsUtility
2/4
Download the Firmware Update1. Beore beginning the rmware download process, close
all other programs except or your Internet browser.
2. Find the Firmware Windows Update Utility associated with
your Crucial m4 SSD at: http://www.crucial.com/support/
rmware.aspx
3. Click the link or the Firmware Windows Update Utilityand select Save to download the ZIP le containing the
rmware update utility to your system.
4. Double-click the ZIP le to extract the les inside. Save
them to your desktop.
Run the Firmware Update1. I not already done, copy the update utility fle to your desktop.
2. Double-click the icon to launch the update utility.
3. A User Account Control box will open:
Ensure that the Veried Publisher is clearly listed as MicronTechnology, Inc. I this is not the case, select No to abort
this operation. Click Yes to proceed i the le is properly
signed.
4. You must accept the License Agreement to proceed. When
you see the ollowing window, click on the License button.
5. Scroll through and read the Sotware License Agreement.
I you wish to proceed, then click the Accept button to
continue.
6. The utility is ready to start the update process. Beore clicking
Continue, ensure that all other work is saved and that open
applications are closed. Clicking Continue will start the
process by closing Windows and restarting your computer.
7. Your computer will restart and boot into the update tool. You
will see the ollowing on your screen:
8. Ater the update tool has ully loaded, you will see the
ollowing:
It is acceptable to update rom either frmware revision 0001,
0002, 0009, 0309, or 010G so you may see any o these revisions
in the above display (immediately below your drives serial
number). I your m4 drive is not listed in the screen display
as above, please see the Troubleshooting Tips section below.
9. The utility will immediately update your drive, indicated by
the ollowing:
10. On most systems, this process will take between 30 to
60 seconds. Some systems may require a longer time to
complete.
11. Upon completion, the ollowing message will display:
12. Ater several seconds, the system will reboot again, restarting
Windows.
13. When Windows successully restarts, the frmware update
process is complete.
-
8/22/2019 CrucialFirmware m42!5!010G WindowsUtility
3/4
Troubleshooting Tips Althougheortshavebeenmadetotestthecompatibilityof
this sotware with various system and chipset confgurations,
it is not possible to test every available system. Thereore,
certain systems (e.g., older systems) may experience
compatibility problems.
Ifyouexperienceissuesafterthetoolreboots,verifythat
you have disabled any drive passwords BIOS.
IfyourRealSSDm4driveisnotrecognizedinStep8of
the Run the Firmware Update section above, it may be
necessary to run this update in IDE mode instead o AHCI
mode, on some older systems. When it is necessary to change
the system to IDE or AHCI mode, it may be necessary to
reboot the system using external media, such as a bootable
CD-ROM. Instructions or running the 010G update rom
bootable media are available on the SSD Support page at
http://www.crucial.com/support/frmware.aspx
SomesystemspreventrmwareupdateswheninRAID
mode. In this case, changing to AHCI or IDE mode may help
to complete the update process. Any RAID confgurations
should be preserved ater the update, when the system is
put back into RAID mode, but check with your systems
user manual beore proceeding.
PeripheralRAIDcardswillnotpassthenecessarycommands
to perorm frmware updates. You may need to move the
target drive onto a SATA host bus adapter or SATA connector
on the motherboard that acilitates these commands.
Thisrmwareupdatetoolmaynotproperlyoperatein
PCs, notebooks or tablets with UEFI-based BIOS. We will
make an update tool available separately, which will support
frmware updates under UEFI (Unifed Extensible Firmware
Interace).
Validating the Current FirmwareRevisionWindows 7 allows the user to check the current rmware
revision o the drive by ollowing these steps:
ClicktheWindowsStartbutton,andselectComputer.
Onthediskiconwhichrepresentsyourdrive,right-click
and select Properties.
Inthewindowthatpopsup,selecttheHardwaretab.
IntheAllDiskDriveslist,highlightyourC400drive,and
click the Properties button.
Inthenextwindowthatopens,selecttheDetailspage.
UnderthePropertypull-downmenu,selectHardwareIds,
and you will see the ollowing display:
Thecurrentrmwarerevisioniscircledinredabove. If
the frmware revision says 010G, no urther action is
necessary.
-
8/22/2019 CrucialFirmware m42!5!010G WindowsUtility
4/4
2012 Micron Technology, Inc. All rights reserved. Information is subject to change without notice. Crucial,and the Crucial logo are trademarks and service marks of Micron Technology, Inc. All other trademarks andservice marks are property of their respective owners. REVISION: 9/24/12 FW010G
Firmware Release NotesFirmware or the m4 SSD is being updated rom version 000F
to 010G.
Firmware 010G is optional or anyone currently running 000F,
as it includes incremental improvements and renements over
these versions, but recommended i the user is experiencing
issues with the current rmware.
Firmware version 010G includes improvements which are
specic or Windows 8 and new UltraBook systems, although
Windows 7 and other operating systems and computer
platorms may also see improvements. Any m4 rmware
version will unction normally in Windows 8. However, the
ollowing improvements were made to meet new certication
requirements or this operating system:
Improvements or Windows 8
ImprovedTime-to-ready(TTR)afteracleanpower
cycle. TTR is now less than 850 milliseconds or all
capacity points. A clean power cycle is dened asapoweroandpoweronsequencewhichfollowsa
STANDBY IMMEDIATE command sent by the host and
acknowledged by the SSD. STANDBY IMMEDIATE is
typically sent during a normal operating system Shut
Down.
Thischangealsoimprovesresume-from-sleeptimeto
meet new Windows 8 requirements.
Trimresponsetimeisreducedfrom50msto20ms
(typical).
Power consumption improvements or some notebookcomputers
HIPM(HostInitiatedPowerManagement)isnolonger
supported. In some notebook computers HIPM can
interere with the SSDs ability to get into and stay in
low power modes using DIPM (Device Initiated Power
Management). Using DIPM alone is the most efcient
method to conserve SSD power.
SATApin11(DeviceActivitySignal)iselectricallyisolated
rom the host when the SSD is in low power modes.
This eliminates a potential leakage path which could
draw unnecessary power while the SSD is in sleep or
hibernate.Thisdoesnotaectmostcomputersystems.
Revision HistoryRev. A 25 September 2012
Initialrelease