CRU® WiebeTech® Forensic UltraDockUser ManualFeatures
• Provideswrite-blockedaccesstoattacheddrives
• Fourseparatehostattachmentoptions(USB3.0,USB2.0,FireWire800,andeSATA)forcompatibilitywithvirtuallyanycomputer
• MultipleLEDsindicateoperationalstatus,includingdiskactivity,hiddenareadetection,errorstate,andthestatusofpowerinputandoutput
• LCDmenuallowsusertoconfiguresettingsandviewinformationonattacheddrives
• Detectsandindicateshiddenareas(HPAsorDCOs)foundonharddrives
• AbletotemporarilyorpermanentlyunhideHPAsandDCOs
• Aluminumcaseforruggeddurabilityandexcellentheatdissipation
• Compatiblewithforensicacquisitionandanalysissoftware
2
Protecting Your Digital AssetsTM
CRU WiebeTech Forensic UltraDock User Manual
1.2 IDENTIFYING PARTS
TakeamomenttofamiliarizeyourselfwiththepartsoftheForensic
UltraDock. This will help you to better understand the following
instructions.
TABLE OF CONTENTS1Pre-Installation 2
1.1PackageContents 2
1.2IdentifyingParts 2
1.3LEDBehavior 3
1.4WarningsandNotices 3
1InstallationSteps 3
2HowtoUsetheLCDInterface 3
3HPA/DCOHandling 4
4UpdatingFirmware 4
5ForensicSoftwareUtility 5
6TechnicalSpecifications 6
1 PRE-INSTALLATION
1.1 PACKAGE CONTENTS
Thefollowing listcontains the itemsthatare included in the
completeconfigurationforthisdevice.PleasecontactCRUif
anyitemsaremissingordamaged:
Accessories Quantity
ForensicUltraDock 1
ACadapterandpowercord 1
USB3.0cable 1
FireWire800cable 1
eSATAcable 1
SATAdriveattachmentcable 1
IDEcable 1
MolexMini-Fittolegacypowercable 1
Metaldriveplate 1
Packetofscrewsandbumpers 1
QuickStartGuideandWarrantyInfo 1
TOP VIEW
FanFailIndicator
Write-BlockIndicator
PowerOutputStatusLED
HPA/DCOIndicator
DriveAccessLED
LCDScreen
Navigationbuttons PowerSwitch
PowerInputStatusLED
ErrorLED
FRONT VIEW
AdminConfigPort
FireWire800Connectors
USB3.0Connector
eSATAConnector
REAR VIEW
eSATAConnector
MolexMini-FitPowerConnector
IDE/PATAConnector
3
Protecting Your Digital AssetsTM
CRU WiebeTech Forensic UltraDock User Manual
• Remove the drives before transporting the Forensic
UltraDocktopreventdamagetothedriveinterfaces.
FORENSIC DEVICE USER ADVISORYBeforeusingthistoolforaccessingsensitivedata,verifythewrite-
blockingfunctionoftheproduct.Youcandosobydownloadingand
installing the Forensic SoftwareUtility and following the instruc-
tionsinitsUserManualforperformingawrite-blocktest.SeeSec-
tion5fordownloadandsetupinstructions.
1 INSTALLATION STEPSa. Usetheprovidedscrewstoattachtheprotectivemetalplate
tothebottomofyour3.5”harddrive.Thisstepisoptional.The
purpose of the bottom plate is to provide protection to the
driveelectronicsofyourharddrive.
b. Ifyou’reattachinganIDE/PATAdrive,configurethejumperson
therearofthedrivetoMaster.Consulttheinstructionsonyour
harddrive’slabel.
c. ConnecttheForensicUltraDocktothedrive(oradapter),using
the IDE ribbonand theMolexMini-Fit to legacypowercable
for IDE/PATAdrivesor theunifiedSATAdata/powercablefor
SATAdrives.
d. Ifyou’reusinganadapter,connectthedrivetotheadapter.
e. Connect the eSATA, FireWire, or USB cable from your
computertothecorrespondingportontheForensicUltraDock.
f. ProvidepowertotheForensicUltraDock.Connecttheincluded
AC adapter or a SATA power cable from the inside of your
computercase.
g. Turnonthepowerswitch.
Youarenow ready touse theForensicUltraDock toaccess the
drive.
2 HOW TO USE THE LCD INTERFACEUse the LCD and 4-button navigation interface to view informa-
tion about the attached drive and the Forensic UltraDock. On
the4-buttoninterface,UpandDownallowyoutoscrollthrough
options,whileEnter selectsanoptionandBackgoesbacktothe
previousscreen.Thecontentsof themenuare listedon the fol-
lowingpage.
SIDE VIEW
DCPowerConnector
SATAPowerConnector
1.3 LED BEHAVIOR
LED COLOR STATE DESCRIPTION
PowerOut Green SolidTheForensicUltraDockispoweredonandoutputtingpower.
PowerIn Green Solid TheForensicUltraDockisconnectedtopower.
Write-Block Green Solid Write-Blockedmodeisenabled.
Error Red SolidThereisaproblemwiththeForensicUltraDock.PleasecontactTechnicalSupport.
DriveAccess Amber SolidorBlinking
Dataiscurrentlybeingaccessedfromtheattacheddrive.
HPA/DCO Green Solid
Ahostprotectedarea(HPA)ordeviceconfigurationoverlay(DCO)hasbeendetectedontheattacheddrive.
1.4 WARNINGS AND NOTICES
Pleasereadthefollowingbeforebeginninginstallation.
General Care
• ThemaincircuitboardoftheForensicUltraDockissusceptibleto
staticelectricity.Propergroundingisstronglyrecommendedto
preventelectricaldamagetotheenclosureorotherconnected
devices, includingthecomputerhost.Avoidalldramaticmove-
ment,tappingontheunit,andvibration.
• Avoid placing the hard drives close tomagnetic devices, high
voltagedevices,ornearaheatsource.Thisincludesanyplace
where the productwill be subject to direct sunlight. DoNOT
allowwatertomakecontactwiththedriveortheForensicLab-
Dock.
4
Protecting Your Digital AssetsTM
CRU WiebeTech Forensic UltraDock User Manual
MENU ITEM SUBMENU ITEM ACTION
ViewDriveInfo DiskTemp Displaysthetemperatureoftheattacheddrive,displayedin°C.
Capacity(MB) Displaysthecapacityoftheattacheddrive,measuredinmegabytes.
Manufacturer Displaysthemanufactureroftheattacheddrive.
Modelnumber Displaysthemodelnumberoftheattacheddrive.
Serialnumber Displaystheserialnumberoftheattacheddrive.
Firmwarerev Displaysthefirmwarerevisionoftheattacheddrive.
HPAsize(MB) Displaysthesizeofthehostprotectedarea,ifany,ontheattacheddrive.Measuredinmegabytes.
DCOsize(MB) Displaysthesizeofthedeviceconfigurationoverlay,ifany,ontheattacheddrive.Measuredinmegabytes.
Diskhealth DisplaystheS.M.A.R.T.statusoftheattacheddrive.
Start/Stops Displayshowmanytimestheattacheddrivehasspunupandspundown.
Powercycles Displayshowmanypoweron/offcyclestheattacheddrivehasundergone.
Badsectors Displaysthenumberofbadsectorsreportedbytheattacheddrive.
ViewDockInfo ProductName Displaysthebrandnameoftheproduct(e.g.ForensicUltraDock)
UniqueID# Displaysthespecific,uniquenumberassignedtotheunitforidentification,akintoaserialnumber.
FirmwareVer.# DisplaystheversionofthefirmwarecurrentlyinstalledontheForensicUltraDock.
CreateHPA/DCO SetDCOSize ThisoptionisonlyavailableifnoHPAexistsonthedrive.ItallowsyoutosetanewsizefortheDCO.PressUporDowntosetanewsizefortheHPA,andEntertoconfirmthechoice.Thediskcapacityavailabletoacomputerwillbereducedbythisamount.Setthevalueto0tohavenoDCO.Valuesexceedingtheavailablecapacitywillnotbeaccepted.
SetHPASize AllowsyoutosetanewsizeforanHPA.PressUporDowntosetanewsizefortheHPA,andEntertoconfirmthechoice.Thediskcapacityavailabletoacomputerwillbereducedbythisamount.Setthevalueto0tohavenoHPA.Valuesexceedingtheavailablecapacitywillnotbeaccepted.
3 HPA/DCO HANDLINGTheForensicUltraDockwillchecktoseeifanyHPAs(hostprotectedareas)orDCOs(deviceconfigurationover-
lays)arepresentonstartup.IfanHPAorDCOisdetected,theForensicUltraDockwillindicatethatonehasbeen
foundandaskwhatyouwanttodowithit.UsetheUpandDownbuttonstoscrollthroughtheoptions,shown
below,andthenpressEntertoselectanoption.
DCO FOUND HPA FOUND
Keep DCO–LeavestheDCOinplace Keep HPA–LeavestheHPAinplace
Remove DCO–PermanentlyremovestheDCO,
exposinganyhiddendatawithinthatarea
Remove HPA Temp–TemporarilybypassestheHPAsothatdatawithinitcanbeaccessed
Remove HPA Perm–PermanentlyunhidestheHPA
5
Protecting Your Digital AssetsTM
CRU WiebeTech Forensic UltraDock User Manual
4 UPDATING FIRMWARECRUprovidesfreefirmwareupdatesfortheForensicUltraDockthroughourConfiguratorapplication.
Downloadithere:www.cru-inc.com/support/software-downloads/configurator-software-download/
Setup Instructions
ConnectthetheprovidedUSBmicro-Bcabletothe“Admin”portontheForensicUltraDockandconnecttheother
endtoyourcomputer.Then,turnontheForensicUltraDock.Finally,opentheConfiguratorapplication.
Ifyourproductisrunningoutdatedfirmware,youwillseeapromptaskingyoutoupdateonceyouopentheCon-
figuratorapplication.Followtheinstructionsontheprompttoupdatethefirmware.
5 FORENSIC SOFTWARE UTILITYTheForensicUltraDockiscompatiblewithCRU’sForensicSoftwareUtilityapplication.Thissoftwareallowsyou
toperformawrite-blocktestonyourForensicUltraDock,displaydetailsaboutattacheddrives,andsavethatdata
toafileforeasyinclusioninacasereport.
Downloadithere:www.cru-inc.com/support/software-downloads/forensic-software-utility/
Setup Instructions
Connect theForensicUltraDocktoyourcomputerwithanattacheddriveasyounormallywouldandturn the
ForensicUltraDockon.ThenopentheForensicSoftwareUtility.
ForinformationonHPA/DCOhandling,seeSection3.
Protecting Your Digital AssetsTM
For more information, visit the CRU web site.
www.cru-inc.com
6 TECHNICAL SPECIFICATIONSProductModels ForensicUltraDock(Model:FUDv5.5)
U.S.PatentNo. 8,090,904
DriveInterfaceTypes&Speeds
PATA/IDE:upto133MB/sSATA(witheSATAcable):upto6Gbps
HostInterfaceTypes&Speeds
eSATA:upto6GbpsUSB3.0:upto5GbpsFireWire800:upto800MbpsUSBMicro-B:upto480Mbps(Adminconfigurationonly)
DriveTypesSupported 2.5”and3.5”rotationalandsolidstateSATAdrives3.5”rotationalIDE/PATAdrives2.5”rotationalIDE/PATAdrives*,Hitachi1.8”drives*,Toshiba1.8”drives*,MacBookAir2010*,MacBookAir2011*,mSATA*,miniPCIePATA*,miniPCIeSATA*,miniPCIeUSB**RequirestheappropriateCRUSATAorPATAadapter
HostDataConnectors One(1)USB3.0connector(backwardscompatiblewithUSB2.0)One(1)eSATAconnectorTwo(2)FireWire800connectors
SupportedOperatingSystems
Windows10,8,7,andVistaWindowsServer2012and2008productfamiliesMacOSX10.4.xorhigher(USB3requires10.8orlater)Linuxdistributionsthatsupporttheconnectiontypeused
Compliance EMIStandard:FCCPart15ClassA,CEEMCStandard:EN55022,EN55024RCM
ProductWeight 0.4pounds(0.18kg)
ProductDimensions 2.95”x4.33”x1.06”(75mmx110mmx27mm)
TechnicalSupport YourinvestmentinCRUproductsisbackedupbyourfreetechnicalsupportforthelifetimeoftheproduct.Contactusthroughourwebsite,cru-inc.com/supportorcallusat1-800-260-9800or+1-360-816-1800.
©2015,2017CRUAcquisitionGroup,LLC.ALLRIGHTSRESERVED.
ThisUserManualcontainsproprietarycontentofCRUAcquisitionGroup,LLC(“CRU”)whichisprotectedbycopyright,trademark,andotherintellectualpropertyrights.
UseofthisUserManualisgovernedbyalicensegrantedexclusivelybyCRU(the“License”).Thus,exceptasotherwiseexpresslypermittedbythatLicense,nopartofthisUserManualmaybereproduced(byphotocopyingorotherwise),transmitted,stored(inadatabase,retrievalsystem,orotherwise),orotherwiseusedthroughanymeanswithoutthepriorexpresswrittenpermissionofCRU.
UseofthefullForensicUltraDockproductissubjecttoallofthetermsandconditionsofthisUserManualandtheabovereferencedLicense.
CRU®andWiebeTech®(collectively,the“Trademarks”)aretrademarksownedbyCRUandareprotectedundertrademarklaw.ThisUserManualdoesnotgrantanyuserofthisdocumentanyrighttouseanyoftheTrademarks.
Product WarrantyCRUwarrantsthisproducttobefreeofsignificantdefectsinmaterialandworkmanshipforaperiodoftwoyearsfromtheoriginaldateofpurchase.CRU’swarrantyisnontransferableandislimitedtotheoriginalpurchaser.
Limitation of LiabilityThewarrantiessetforthinthisagreementreplaceallotherwarranties.CRUexpresslydisclaimsallotherwarranties,includingbutnotlimitedto,theimpliedwarrantiesofmerchantabilityandfitnessforaparticularpurposeandnon-infringementofthird-partyrightswithrespecttothedocumentationandhardware.NoCRUdealer,agent,oremployeeisauthorizedtomakeanymodification,extension,oradditiontothiswarranty.InnoeventwillCRUoritssuppliersbeliableforanycostsofprocurementofsubstituteproductsorservices,lostprofits,lossofinformationordata,computermalfunction,oranyotherspecial,indirect,consequential,orincidentaldamagesarisinginanywayoutofthesaleof,useof,orinabilitytouseanyCRUproductorservice,evenifCRUhasbeenadvisedofthepossibilityofsuchdamages.InnocaseshallCRU’sliabilityexceedtheactualmoneypaidfortheproductsatissue.CRUreservestherighttomakemodificationsandadditionstothisproductwithoutnoticeortakingonadditionalliability.
FCC Compliance Statement: “ThisdevicecomplieswithPart15oftheFCCrules.Operationissubjecttothefollowingtwoconditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation.”
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassAdigitaldevice,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferencewhentheequipmentisoperatedinacommercialenvironment.Thisequipmentgenerates,uses,andcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructionmanual,maycauseharmfulinterferencetoradiocommunications.Opera-tionofthisequipmentinaresidentialareaislikelytocauseharmfulinterferenceinwhichcasetheuserwillberequiredtocorrecttheinterferenceatthisownexpense.
IntheeventthatyouexperienceRadioFrequencyInterference,youshouldtakethefollowingstepstoresolvetheproblem:
1) Ensurethatthecaseofyourattacheddriveisgrounded.2) UseadatacablewithRFIreducingferritesoneachend.3) UseapowersupplywithanRFIreducingferriteapproximately5inchesfromtheDCplug.4) Reorientorrelocatethereceivingantenna.
PartNumber:A9-000-0057Rev1.2
FOROFFICEORCOMMERCIALUSE
1000SETechCenterDrive,Suite160,Vancouver,WA98683